assembly. The instructions

image

Contents

1. 26 eisys healthcare rev 13 10 2011 pic 1 8 4 Mounting the ballast housing 8 5 Attach power switch to desktop Locate the two pre tapped holes under desk top and to the right of control panel Attach switch box to bottom of desktop with two 2 1 3 4 wood screws provided Pic 1 Switch box should be flush with front edge of top Manage wires with provided wire clips Desktop Mounting Use the supplied 4 wood screws Locate the 4 predrilled holes centered just forward of the rear triangular tube Pic 1 Attach ballast here Cable Tray Mounting for Generation II Cable Trays only Use the supplied 4 bolts and thumbscrews Insert in the 4 holes located in the bottom of the cable tray Tighten Pic 2 pic 1 pic 2 Heavy Duty Height Adjustable Arm with 3rd Post Installation Instructions 2 eisys healthcare inc Heavy Duty Height Adjustable Arm with 3rd Support Post 28 EI RSRC Notice Due to the weight of Diagnostic Monitors specific heavy duty tilter vesa plate arm and mounting cup must be used for this equipment In addition a specially designed support post that correctly accommodates mounting of the heavy duty cup arm assembly is also required and must be in place directly beneath the monitor arm assembly The instructions below present the specific parts and steps required to mount a larger scale Diagnostic Monito
2. 8 eisys healthcare rev 13 10 2011 pic 1 6 INSTALLATION OF GAS SPRINGS not appliciable if factory installed pic 2 Align the stabilizing plate with the piston rod of the gas spring side of the plate with countersunk holes facing away from spring Plate has to be rotated clockwise on the piston rod to secure pic 1 Center gas spring with stabilizing plate into column and align plate with 4 screw holes Mount the plate pic 2 using the four 4 Torx head countersunk screws and Torx25 tip Tighten screws evenly to compress cylinder until plate is flush with leg column Note Tighten screws slowly in an alternate pattern making sure plate compresses evenly 9 eisys healthcare rev 13 10 2011 NOTE IF THE MODEL NUMBER ENDS IN Z OR ZM AFTER THE GAS SPRINGS ARE INSTALLED THE FRAME HAS TO HAVE APPROXIMATELY 88 LBS OF WEIGHT ADDED WHILE RAISING OR LOWERING THE TABLE ASSEMBLY TO ADD WEIGHT LEAN ON FRAME EXERTING APPROXIMATELY 88 LBS OF PRESSURE WHILE PRESSING AND HOLDING THE UP OR DOWN ARROW CAUTION FAILURE TO DO THIS MAY DAMAGE MOTOR OR GEARS 7 ATTACHING TABLE TOP pic 1 pic 2 pic 3 pic 4 Align frame with top support structure and attach columns to top pic 2 with pic 3 with supplied 8 4 Allen head bolts 4 per column Note When table top and columns are aligned the two plates will be flush Jobsite Conditions A If you are assembling the workcenter
3. pic 2 pic 1A 22 eisys healthcare rev 13 10 2011 7 CPU LINE CONDITIONER INSTALLATION The GMCZ 6 comes with one connecting column and one Support Plate for complete set up pic 1 1 Determine the width of your CPU case Loosen the two black thumb screws on the side to extend the standard support plate but do not extend beyond the thumb screws If the CPU is wider than 5 1 4 then you will need to add the extensions that come stored under the support bracket This will give you a maximum width of 11 pic 2 To add the extensions remove from below storage area and remove the factory installed outside support plate and turn to the underside Remove the 2 Allen head set screws with the supplied Allen wrench Insert the smaller end of the extensions hole for the set screw facing down into the standard tubes Replace the set screws insert the end caps from the accessory pack and replace the support bracket Adjust to width of CPU and tighten thumb screws pic 3 2 Mounting the GMCZ 6 on the workcenter leg pic 4 This can be mounted to the outside of either leg on the work center preferably out of foot area If mounted inside then the maximum height of the CPU case cannot exceed 20 3 4 due to the crossbar of the desk frame Once this is determined use the supplied 4 Allen wrench to tighten the clamp to the leg profile of the leg at the highest point on the leg 3 An additional S
4. 9 525mm Phillips Pan Head Screw part G and Tilter Washer part F in bottom of arm Pic 4 note This is a security measure to prevent the monitor from being easily lifted off the arm Pic 5 Pic 6 Pic 8 Pic 9 Step 5 Using supplied large Allen Wrench part H adjust tension on tilter to prevent monitor from dropping down or being to stiff to adjust Pic 5 Pic 7 Step 6 Using supplied large Allen Wrench part H adjust tension of arm Increase counter clockwise or decrease clockwise tension as necessary and as dictated by weight of the monitor Monitor and arm must be parallel to desk surface when calibrating arm Pic 6 Step 7 Adjust set screws at indicated locations to increase clockwise or decrease counter clockwise friction tension for horizontal movement The tension is generally set at the factory but over time may need to be adjusted Pic 7 Step 8 Insert monitor cable into two cable retainers and place Cable Cap part J Pic 8 Pic 9 Calibrated monitor and height adjustable arm with cable in place 20 eisys healthcare rev 13 10 2011 4B Mounting Manual Height Adjustable Arm pic 1 pic 3 pic 2 Place accessory on rail in approximate final location Once in final location completely secure by securing V clamp with 2 4 Allen head bolts Attach 100mm VESA plate to monitor using screws supplied with monitor pic 2 LCD Holder quick release plate Slide monitor
5. General Manager Dick Gardner p 205 329 7053 dick gardner eisys inc com Technical Assistance Paul Allen p 205 329 7055 paul allen eisys inc com
6. eisys healthcare rev 13 10 2011 1 PREPARING TABLE TOP cont pic 8 1C Pencil Tray 1B Preparation for the Control Panel pic 6 pic 7 Locate the pre marked holes for the control panel mounting plate Pre drilled holes should allow this Position control panel mounting plate at pre marked holes pic 6 This bracket allows the control panel to slide approx one inch front to back Place control panel on top of mounting slide plate and position control panel so that when slid to front of plate the panel is flush with front edge of table top Fasten with supplied 3 Phillips head screws using 1 Phillips bit ONLY CAUTION DO NOT OVER TIGHTEN CONTROL PANEL WILL NOT SLIDE Use the 2 holes located on front edge of top the opposite side from the control panel see Pic 8 Note The control panel cannot be installed or secured to the top until top is mounted to the frame and workcenter is in its final location Be sure control panel cable comes from behind and over cross rail Note Caution should be used not to strip the 1 Phillips head screw CAUTION IS NEEDED AS TO NOT OVER TIGHTEN SCREWS OVERTIGHTENING SCREWS MAY CAUSE THEM TO PUNCTURE LAMINATE ON DESK SURFACE 15 eisys healthcare rev 13 10 2011 pic 10 1 PREPARING TABLE TOP cont Attach cup holder at pre tapped holes on the un der side of top left or right corner with supplied 3 3 4 Phillips head
7. wood screws Note Preferable location is the opposite side of the CPU placement 1D Cup Holder 1F User s Manual User manual is located in the Frame Box Pic 11 Remove film backing from packet and apply packet on underside of table where indicated in pic 12 pic 11 pic 12 16 eisys healthcare rev 13 10 2011 2 MOUNTING RAIL POSTS pic 2 pic 1 Post should be mounted on table top with 4 supplied 6mm allen head bolts Place one full washer on table top surface and the second half washer on the underside of the table top Pic 2 and Pic 3 CAUTION Rail and Rail Accessories can not be installed until table top is attached to leg assembly and placed upright 3 MOUNTING RAIL pic 1 Pic 1 shows position of installed rail and posts NOTE Rail may be mounted in front or behind support posts CAUTION Loosen 2 5 mm allen screws A pic 2 and the 2 mm allen screw B pic 2 so that they are recessed from the inside of the rail collar or damage to post could occur Slide rail down evenly over rail posts so that the bottom of rail collar is even with the 2nd to last ring at the bottom of post approximately 10cm from work top Note The rail height is determined by the size and style of monitors A good starting position is to place the collar at the second ring from the bottom of the rail posts approximately 10cm from the work top It is also important to position the rail col
8. 5 eisys healthcare inc 2 ASSEMBLY cont Insert the bottom portion of the Height Adjustable Arm into the cup 4 Attach the provided 100 X 200 vesa plate to the back of the monitor Use the factory screws when possible Note some monitor models may require the back housing to be removed to accommodate the vesa plate particularly the Barco 6MP Niofusion 5 The tilter portion of the arm will fit into the top hole of the Height Adjustable Arm To adjust the tilter use the supplied Allen wrench to tighten or loosen the tilter mechanism for the desired tilt angle of the monitor 6 6 eisys healthcare inc 2 ASSEMBLY cont To calibrate the arm s tension so the monitor will stay in place once positioned extend the monitor arm fully and position both joints parallel to the desk top Use the supplied Allen wrench and insert where indicated with the red arrow Turn the Allen wrench clockwise to loosen the tension and counterclockwise to tighten the tension The arm is calibrated when the monitor stays at the level that the user positions it and does not drift when released 7 For troubleshooting or technical support please call Tim House at 205 937 0911 7 eisys healthcare inc p 888 941 1942 f 205 941 1781 info eisys inc com www eisys inc com 1 1 2 2 8 th S t r e e t S o u t h B i r m i n g h a m A l a b a m a 3 5 2 3 3 forward thinking solutions gt healthcare gt education gt office Contacts
9. SA Adapter Plate 1 7VESA75 100mm VESA Adapter Plate 1 7VESA100 10 32 x 3 8 9 525mm Phillips Flat Head Screw 4 701164 M4 12 Phillips Pan Head Screw 4 702096 Tilter Washer 1 704197 10 31 x 3 8 9 525mm Phillips Pan Head Screw 1 704197 7 32 5 563mm Allen Wrench 1 701127 3 32 2 388mm Allen Wrench 1 700146 Cable Cap 1 102043 9 5A Mount Column 1 401328 3 8 16 Nylon Stop Nut 1 701418 3 8 16 x 7 8 22 225mm Button Socket Cap Screw 1 701122 A B C D E F G H I J H I J 19 eisys healthcare rev 13 10 2011 4A 2 Calibrating the Advanced Height Adjustable Arm Pic 1 Pic 2 Pic 3 Pic 4 Step 1 Insert the end of the adjustment arm into Mounting Cup part H Pic 1 Step 2 Determine VESA Plate size prior to assembly The VESA plate size is determined by the mounting hole pattern on the rear of the monitor Standard sizes are 100mm square and 200mm square Attach correct VESA Plate to Monitor Tilter part A with the 4 10 32 x 3 8 9 525mm Phillips Flat Head Screws part D Pic 2 note VESA plate in box does not have B or C designation on plate Step 3 Attach the VESA Plate and Monitor Tilter to the monitor using 4 M4 12 Phillips Pan Head Screws part E Pic 3 Step 4 Mount the Tilter and monitor into the top section of the arm Insert 10 32 x 3 8
10. assembly manual for GO2 WorkCenter 2 eisys healthcare rev 13 10 2011 section one workcenter assembly 3 eisys healthcare rev 13 10 2011 TABLE OF CONTENTS Tools Hardware 4 section one workcenter assembly Components 5 Feet Assembly 6 Resetting Control Panel 7 Gas Spring Preperation 8 Preparing the Table Top 12 Attaching Accessories Attaching the Table Top 9 Frame Layout 5 section two accessory installation Mounting Rail Posts 16 Mounting Rail 16 Mounting Rail Accessories 17 Mounting Table Top 17 Accessories Mounting Table 21 Frame Accessories Mounting CPU 22 UPS Holders Rail Mounted Light 24 Assembly Contact Information 27 and Assistance Tools Hardware 11 4 eisys healthcare rev 13 10 2011 Phillips amp flat head screwdriver 1 Phillips Bit Metric Allen wrenches 2 8mm Long T handle 4mm helpful Wrench or socket 7 8mm Torx head screwdriver T25 TOOLS NEEDED FOR WORKCENTER ASSEMBLY HARDWARE LIST FOR WORKCENTER ASSEMBLY Column Mounting Plate screw T25 20mm 4 at each end of each column already installed Table Top mounting Allen bolt 5mm or 4mm x 25mm 8 su
11. et Strip Cable Tray Generation II 6B Control Panel 6C Pencil Tray 6D Cup Holder 6E User s Manual 6F Wire Management 6F 1A Multi Outlet Strips amp MBMO U 6 Duplex with Generation II Cable Tray no MBMO U required MBMOU is an adapter plate used to mount power strips to Generation I Cable Tray The 2 Duplex and 4 Duplex can also be mounted to the Generation II Cable Tray using the MBMOU mounted to the slotted door of the cable tray Mount in cable tray as seen in pic 2 and in Generation II as seen in pic 2A Use plastic thumbscrews to secure pic 2B 4 Duplex 2 Duplex Mount 6 Duplex Multi Outlet strip in Generation II cable tray as seen in pic 3 Use screws to secure pic 3B pic 3A pic 3 Note Pre tapped holes are used to aid in accessory placement on underside of top 13 eisys healthcare rev 13 10 2011 1A 1 Cable Tray Generation I pic 3 pic 4 pic 5 Position cable tray as seen in pic 3 and pop tray into place by slide lip of cable tray under triangular tube Use mounting brackets 2 Pic 4 and nut bolts to secure tray to triangular tube Pic 5 1A 2 Cable Tray Generation II Center cable tray over triangular tubes with the hinged door facing toward the rear of desktop Pic 6 Center cable tray left and right of desktop Pic 7 Attach using the 3 4 wood screws Pic 8 pic 6 pic 7 pic 8 14
12. in the room where it will reside you can assemble the entire unit upside down and then place right side up B If you are assembling the workcenter outside of the room where it will reside the control panel cannot be attached to the top until the table top and leg assembly are placed in the final room location 10 eisys healthcare rev 13 10 2011 section two accessory installation 11 eisys healthcare rev 13 10 2011 Hardware List section two Phillips head screwdriver 1 Phillips Bit Metric Allen wrenches 2 8mm Long T handle 4mm helpful Wrench or socket 7 8mm TOOLS NEEDED FOR ACCESSORY INSTALLATION Phillips 3 4 wood screw used for Light Ballast 4 unless Generation II Cable Tray is used Cup Holder 3 Phillips 1 1 2 wood screw Light Control switch box 2 Wire management clips for Control Panel Cable Rail Post mounting Allen bolt 6mm x 50mm 4 supplied Rail Post mounting Allen set screw 4 supplied installed 12 eisys healthcare rev 13 10 2011 6D 6C 6B 6A 1 PREPARING TABLE TOP pic 1 Pic 1 shows position of all standard optional accessories attached to the bottom of the table top and of user s manual placement location Open Box B table top with finished top facing down exactly as shown in pic 1 this makes for easier installation of accessories and frame space permitting 6E pic 2A pic 2A pic 2B 6A Multi Outl
13. ite side installation is identical pic 1 pic 2 pic 3 pic 4 pic 5 2 spacers 24 eisys healthcare rev 13 10 2011 Shown from front with shield rotated to aim light on wall Shield may be rotated as desired to aim light in any direction Shown from back with shield removed 8 ASSEMBLY OF RAIL MOUNTED LIGHT WLTC TOOLS NEEDED FOR ASSEMBLY Phillips head screwdriver Allen wrench 5 mm 8 1 COMPONETS A Ballast Housing w ballast 4 3 4 Phillips Head wood screws B Light shield B 1 Optional Blue Lens C Flourescent lamp amp cable D 1 Desk mounted switch box 2 13 4 Phillips Head wood screws D 2 Switch and cable E Light posts 2 w clamps 4 5 Allen Head screws F Power cable G Black Nylon Knurled Screws for Light Shield Tension 2 not pictured A B C D E E F B 1 25 eisys healthcare rev 13 10 2011 pic 1 Pic 1 Insert lamp ends into posts until seated Pic 2 Shows lamp correctly seated pic 1 pic 2 8 2 Position lamp in post ends 8 3 Attach support posts to rail Attach light posts using the bottom clamps and Allen bolts finger tight Feed lamp power cord through rear slot in clamp Standing behind the desk the cord should come through the left post Mount swivel clamps so that posts can be mounted in any location on a corner desk with a curved monitor rail NOTE Light post should be centered and vertically straight
14. lar on one of the post rings so the set screw A in Pic 3 will fully tighten on the post Tighten set screws carefully not to over tighten Once rail is positioned on post finish tightening the bolts securely on the post under the top step 1 pic 3 B A Note DO NOT tighten posts completely until rail is positioned on posts step 2 pic 3 pic 2 17 eisys healthcare rev 13 10 2011 A Advanced Height Adjustable Arm model 3500 250 450 800 RF C Phone Post TSA RF D WLTC Indirect Light See Section 7 4 MOUNTING RAIL ACCESSORIES pic 1 NOTE Pic 1 shows how the accessory arms should be spaced equally across rail B Manual LCD holder model LCD QRE RF 4A Mounting Advanced Height Adjustable Arm pic 1A pic 2 Place accessory on rail in approximate final location Secure V clamp with 2 4 Allen head bolts pic 1A in front 1B in back Attach 100mm VESA plate to monitor using same 4 screws supplied with monitor or the 4 longer BLACK screws supplied with each Advance Height Adjustable Arm pic 2 pic 4 pic 3 pic 1B The Advanced Height Adjustable Arm will require calibrating after mounting on the rail Follow the instructions on the next two pages to calibrate each arm 18 eisys healthcare rev 13 10 2011 4A 1 Advanced Height Adjustable Arm Model 6654 parts list Monitor Tilter 1 8013 75mm VE
15. ost floor ing surfaces including carpet NOTE If customer requests a change in height you may line up the feet on higher numbers if you want the minimum table height to be greater than 68cm 26 75 Each mark represents one 1 cm Total range is 10 cm or 4 Be careful to line up all four feet to the same number as to make sure the workcenter is level pic 4 pic 2a 7 eisys healthcare rev 13 10 2011 4 RESETTING THE CONTROL PANEL Keeping frame upside down plug desk in You will see blinking zeros on the control panel pic 1 To reset the control panel press and hold the down arrow button until column reaches its lowest position Continue to press the down arrow until diplay reads 067 or 068 The workcenter controls are now reset NOTE You cannot raise the table until you reset the column at its lowest position YOU ARE NOW READY TO RAISE THE TABLE ASSEMBLY USING THE UP ARROW pic 1 pic 2 5 GAS SPRING PREPARATIONS not appliciable if factory installed Extend the leg columns completely by pressing and holding the up arrow until top reaches 120cm shown on display pic 3 Remove the cover stabilizing plate on the foot side of the column by loosening the four 4 coun ter sunk screws pic 4 THE COLUMNS HAVE TO BE COMPLETELY EXTENDED BEFORE INSTALLING GAS SPRINGS BECAUSE OF THE RISK OF INJURY BY THE PRESSURIZED GAS pic 3 pic 4
16. pplied FRAME 5 eisys healthcare rev 13 10 2011 1 COMPONENTS Box A Frame and optional accessories Box B Table top Support Structure Cable Outlets 3 Unpack and layout all components from box A All the fasteners are in individual bags taped to the relative component A Frame B 2 short feet 2 long feet Options C Monitor rail D 2 monitor rail posts E Cable Tray with or without MBMOU and power strip F Accessory Boxes Lay frame upside down The control panel cable always exits the cross rail at the back of the frame Motor housing is flush with the back side of frame The angled side is the front of the frame The short legs always attach at back of frame The long legs always attach at front of frame Front Back 2 FRAME LAYOUT A B B C D E Box A Box B 6 eisys healthcare rev 13 10 2011 pic 4 3 FEET ASSEMBLY pic 3 pic 2 pic 1 Using 4mm long T handle Allen wrench loosen but do not remove completely Allen bolts on foot binding clamp pic 1 Align foot and binding clamp in grooves of leg pic 2 and slide down to the numbered markings pic 2a pic 2a The top of the foot when frame is turned upright should stop on the line between zero 0 and one 1 This sets the minimum table height to 68cm 26 75 and will al low for adequate bottom of frame clearance for m
17. r including instructions for converting an existing support post part 28 EI 3 RSRC that might be used as part of the installation Note It is critical and a requirement that any diagnostic monitor in excess of 35 pounds be mounted per these instructions 3 eisys healthcare inc 28 EI 3 RSRC either previously purchased or included with this order 1 Parts List Height Adjustable Arm with Tilter Height Adjustable Arm Mounting Cup Heavy duty top portion of the rail clamp 2 of the M5 0 8X50 DIN 12 9 hardened steel bolts for attaching clamp to the rail 1 8 metric 1 25x30mm hardened steel countersunk head screw w 12 9 rating 4 eisys healthcare inc 2 ASSEMBLY If you currently have a 28 EI 3 RSRC remove the two silver screws and top portion of the normal rail clamp This top portion of the clamp should have two screw holes that ARE NOT recessed and NO center threaded hole Set aside this top piece and the two silver screws 1 Replace the top portion of the clamp with the HD portion using the 2 4 metric Allen head M5 0 8X50 DIN 12 9 hardened steel bolts in the recessed holes on top of the new HD clamp 2 Using 1 8 metric 1 25x30mm hardened steel countersunk head screw attach the cup portion of the Height Adjustable Arm with a 3 8 Allen wrench to the top clamp Be sure to position the cup recess over the small steel nipple Tighten securely to a snug fit Caution Do not over tighten 3
18. upport Bracket pic 5 can be ordered to stack multiple or a mix of CPUs and UPSs Measure the height of the piece that will sit in the bottom support to determine where the height of the additional support will be located 4 The Accessory Pack pic 3 also contains rubber leveling bumpers Normally 3 large ones spaced evenly on the outside support ledge will adjust the CPU to level pic 4a pic 1 pic 2 pic 4 pic 3 pic 5 pic 4a 23 eisys healthcare rev 13 10 2011 7 1 GMZC6 SPE INSTALLATION After assembly of the GMZC6 if necessary install the GMCZ6 SPE accessory Remove SPE accessory from box including bag with 2 spacers as shown pic 1 NOTE When mounting GMZC6 IN BOARD in conjunction withe the NEW eisys HINGED CABLE TRAY the SPE accessory MUST be installed to protect the CPU from cable tray collision when loweing the desk Install SPE as shown once you have set the proper width of the SP for your particular CPU tower pic 2 NOTE The SPE slides under the SP rear rod and over the front rod Next select the appropriate spacer to allow secure tightening of the SPE to the SP rear extension rod pic 3 Align and finger tighten knurled screw with spacer After final placement of CPU in holder finish tightening both knurled screws to their final secure position pic 4 Finished product should be as shown pic 5 NOTE oppos
19. with plate into quick release receiver on the end of the monitor arm When firmly seated the release arm on the VESA will lock into place into the receiver Pic 3 shown without monitor 4C Mounting Third Rail Support Post Place accessory on rail in approximate final location Mark screw locations pic 1 Drill holes in desktop for each screw pic 2 Attach post with supplied 4 Allen Bolts pic 3 and half washer on bottom pic 4 pic 1 pic 2 pic 3 pic 4 21 eisys healthcare rev 13 10 2011 pic 1b 5 MOUNTING TABLE TOP ACCESSORIES pic 1 Remove organizational hole cover pic 1 1A Remove cap amp sleeve of org hole Position Desk Fixing Post w full washer over org hole Insert bolt and small washer from under desk into top with 300 mm post Appllicable with 1B Telephone Post Holder 1C Paper Tray Note Org sleeve does not need to be removed 1D LCD Arm Manual Height Adjustment LCD QRE DF INSTALLATION NOTE Paper tray and Advanced LCD Height Adjustable Arm can also be mounted to the desk top with optional desk clamp NOTE Step by step installation of triple paper tray in box Desk Edge Clamp not applicable when using org holes pic 1C 6 MOUNTING POWER DOME Remove gromet hole cover Insert wires of power dome through grommet hole pic 1 Slide both halves together and place in grommet hole until flush with desk top pic 2 pic 1D pic 1