1. O O o 1 o 1 Display type PW5 valueisdisplayed 14 o o LedOff theledisturnedoff O o 1 1 Led On The led is turned on steady sid ois b limo anemie ne 1 simulates an alarm condition POL 100 can send the following commands to a module 1 1 1 User Bitscanbeedited 1 o 0 Displaytype PWSvalueisdisplayed 1 O 1 Relay Off the outputisde energized ATTENTION Output is energized internal relay MN DT 9621 POL 100 User Manual 5 COMMUNICATIONS This option allows the POL 100 to communicate with a PC The installation of USB driver is required so that Windows enables the serial port for communication Once the USB driver has been installed click on Control Panel gt System gt Hardware gt Device Manager The USB Serial Port will be displayed with the number of the first serial port available in the PC in this case COMI Administrador de dispositivos Archivo Acci n Ver Ayuda c m f8 R ERA 2 Controladoras de bus serie universal USB 32 Controladoras de host de bus IEEE 1394 l Controladoras IDE ATA ATAPI F Dispositivo de memoria de PCMCIA y Flash 39 Dispositivos de im genes Dispositivos de interfaz de usuario HID Propiedades de USB Serial Port COM1 4 Dispositivos de sistema Dispositivos de sonido v deo y juegos 4 Equipo M dems e Monitor Mouse y otros dispositivos se aladores Be Procesadores Y Puertos COM
2. 0 fi OT IPIER denia prg Iberia 08911 BADALONA BARCELONA i Tel 93 497 39 60 Fax 93 465 86 35 by Hon eywell www honeywelllifesafety es Diagnostic Tool POL 100 Analogue loop verification tool 1 MULTIMETER 2 AUTOLEARN User Manual MN DT 962 9 DECEMBER 2008 Information in this document is subject to change without notice POL 100 User Manual INDEX Page TINTRODYUG MON art ii iii ii 3 2MANMENO sarai 4 3 AUTO LEARN AULODIOOhaMaGION ess ups 6 4 DEVICE POLLING an dai a aro 7 COMMUNICATIONS eee 9 MN DT 9621 2 1 MULTIMETER 2 AUTOLEARN 3 SELECT DEVICE 4 REGISTER LOOP 5 CONFIGURATION 6 COMMUNICATIONS MN DT 9621 POL 100 User Manual 1 INTRODUCTION POL 100 is a hand tool designed for analogue tool diagnostics by which the faults in the fire loop can be easily located and diagnosed POL 100 electronics are contained in an ABS box h 19 05mm w 10 16cm x d 3 27cm with rubber protection and a stand to place the device on a flat surface and visualize the display with a 45 angle POL 100 includes rechargeable Ni MH batteries 1700mA 8 4V These batteries can be charged directly from the control panel battery they accept 12 Vdc 2Amp external supply or with the supplied charger by connecting it to the 220 Vac mains power The plug and play terminals allow an easy connection to the analogue loop Moreover connection clips are supplied so that POL 100 can be easily conne
3. amp LPT aF RIM virtual Serial Port v2 COM15 AIR al 0M16 5 USE Serial Port COM1 Ss Unidades de disco LA Unidades de DVD CD ROM See Vol menes de almacenamiento oma T i General Configuraci n de puerto Controlador Detalles F USB Serial Port COM1 Tipo de dispositivo Puertos COM amp LPT FTDI HH E 4 Fabricante en USB Serial Converter Ubicaci n Estado del dispositivo Este dispositivo funciona correctamente ERRE Si este dispositivo presenta conflictos haga clic en Solucionador c problemas para resolverlos Honeywell Life Safety Iberia Headquarters in Barcelona Tel 93 4973960 Fax 93 4658635 Office in Madrid Tel 91 1314800 Fax 91 1314899 Office in Seville Tel 95 4187011 Fax 95 5601234 Office in Bizkaia Tel 94 4802625 Fax 94 4801756 Office in Portugal Tel 00 351218162636 Fax 00 351218162637 www honeywelllifesfety es
4. to be lower after this momentary peak current MN DT 9621 POL 100 User Manual 3 AUTOLEARN This option will display sensors and modules installed and addressed in the loop The display will show the type of total devices found and their addresses F1 key allows the user to start an Autolearn This is an automatic function which carries out constant samplings from 00 to 99 addresses looking for any change since the last reading Whenever a device is found out the device type will be displayed next to the device address e T Thermal e I lonic e 0 Optical e L Laser e P Pinnacle e M Multicriteria Optical Thermal or Smart 3 e S Smart 4 When there is a loop short circuit this symbol h will be displayed next to the battery status indication Moreover buzzer will activate until this fault is cleared When there are two or more sensors or two or more modules with the same address this symbol will be displayed next to the address device In order to identify the device with the wrong address the user should activate the Manual learn mode option and select with the key arrows the duplicated addresses F1 changes the learn mode from MANUAL LEARN only one polling to AUTO LEARN constant polling If the MANUAL LEARN option has been selected by pressing F2 a new short polling will show changes between the last and the current reading MN DT 9621 POL 100 User Manual Once th
5. F3 key gt Screen Res SCREEN NEGATIVE The cable screen must not have any link between positive and negative loop If a value different to infinitive is showed on the POL 100 display please verify the links Finally the resistance value between both screen terminals S out and S In will be calculated by pressing F4 The cable screen section is lower than negative and positive loop cables therefore the values for this screen will double the positive and negative loop cable values If positive loop has 15 ohms resistance the screen resistance value will be 25 40 ohms approx When the screen resistance value displayed is lower than any circuit this means that the cable screen has no continuity and will be displayed Option P 1 2 MULTIMETER EARTH Option 2 Earth will display the resistance value between the cable screen and the earth connector The cable screen must not be linked to Earth If is displayed please check the point where the loop screen is in contact with the building earth in the installation Option P 1 3 MULTIMETER VOLT CURRENT By selecting Option 3 VOLTAGE CURRENT the user can verify the current drawn from devices at 24 5 and O Vdc and see the voltage drop in the loop return By pressing F1 key the Loop Out terminals will have 24Vdc and the return voltage and the required current of loop devices will be displayed This current although can be 20 100mA initially will have
6. cted to any base or module at any installation point The USB connector allows the transmission of up to 200 000 registers previously stored or the graphic illustration of the entries by using Windows software that is able to communicate up to 115 200 bps Display features 320x240 pixels 81 4x61mm visible area and blue backlight The display shows the configuration of 99 sensors and 99 modules information about the type of device total and subtotals of polled devices POL 100 is turned on by pressing the power key under the F1 key if batteries are charged The battery status is displayed on the top right corner of the display If POL 100 is connected to a 12Vdc external power supply a mains cable will be displayed together with the indication of battery charging Function keys F1 F4 allow direct and easy access to different functions Arrow keys allow the user to navigate through the menus sensor and module screens and highlight the required option The required option can be selected with the Enter key and the Esc key can be used to go back to the previous menu The number keys can be used also to select the different menus e g to enter 1 Multimetro menu number 1 key should be pressed POL 100 User Manual 2 MAIN MENU MULTIMETER AUTOLEARN SAMPLING DEVICES REGISTER LOOP CONFIGURATION COMMUNICATIONS Ser e The option 1 of Main Menu Multimeter allows the user to check the cable resistive values and ensur
7. e manual learn has been finished the device addresses can be verified By pressing the arrow keys we will move through the different addresses and when one of them is selected the POL 100 sends an order to the device with that address so that its LED lights on By pressing F3 key the selected device is added to the SAMPLING DEVICES screen This screen will show up to 10 devices We can get access to the SAMPLING DEVICES screen and visualize the PW pulses of the selected device by pressing the Enter key or going back to the main menu and press 3 SAMPLING DEVICES 4 SAMPLING DEVICES This option allows the user to visualize the response value range of the selected devices Up to ten devices can be displayed Devices visualized in this screen can be added or cleared manually by pressing F1 and F2 respectively That means that from this menu when the user presses F1 a new device will be added to the polling list always with the next address For example if the device with address 40 is selected and we press F1 the sensor 41 will be added The addresses from 100 to 199 belong to modules from 00 to 99 Thus if sensor 99 is selected and F1 is pressed the following device added will be 100 which stands for module 00 The devices displayed on this screen can be added directly in the AUTOLEARN screen by pressing F3 on the required address Devices can also be added or cleared from the screen by pressing F1 and F2 respectively Each
8. e that the loop is closed and the values are within the range recommended by manufacturer Multimeter menu has three options 1 RESISTANCE 2 EARTH 3 VOLT CURRENT Option P 1 1 MULTIMETER RESISTANCE When selecting RESISTANCE the following data appear R POSITIVE ohms RNEGATIVE ohms If there is continuity at both loop ends the RESISTANCE display will show the resistive value of each of the cables These values should be below 20 ohms up to 40 ohms altogether according to manufacturer s specifications A 1 5mm cable has a resistance of 13 3 ohms Km while a 2 5mm cable has lower resistance 7 9 ohms Km approx Resistive values vary depending on the cable length according to the following table _ soom 750m 1000m 1250m 1500 m 2000 m 2500m 3000 m 12 16 24 2 5 mmPcable_ 4 l 6l 8 For example the resistance for a 1 5mm cable section and 1500 m cable length is 20 ohms per cable 40 ohms both A higher distance with a 1 5mm2 is not recommended because the total resistance would be more than 40 ohms MN DT 9621 4 MN DT 9621 POL 100 User Manual When the resistance exceeds 99 ohms the display will show If the cable screen is linked to S Screen terminals Out and In the user can check resistive values with positive terminal by pressing F2 F2 key gt Screen Res SCREEN POSITIVE F3 key will show the resistance between the cable screen and negative loop
9. line provides information of each selected device and the left column can display the response current value or the alarm analogue value To change from one to another value F4 key must be pressed POL 100 carries out a polling of the devices displayed every 3 seconds and record their values at the same time By pressing F3 key the user can change the display mode of the Sampling devices screen e CURRENT The display shows real time values e LOWEST The display shows the lowest value from the first access to this menu e HIGHEST The display shows the highest value of each saved pulse e AVERAGE The average value is displayed MN DT 9621 POL 100 User Manual In order to change the device address or to obtain more information about a specific device the ENTER key should be pressed and the display will change to P 3 1 CONF SAMPLING DEVICES This display shows the device address The user can highlight and edit the address in order to change it from 00 to 99 for sensors and from 100 to 199 for modules If the COMMAND line is highlighted the command sent by POL 100 to the specific sensor or module can be modified Depending on the selected values it is possible to activate output modules sounders electromagnets or even extinctions Any output that may lead to unwanted actions must be disconnected POL 100 can send the following commands to a sensor 41 1 1 JUser Bits canbe edited O