Home

IMPSEC 5000

image

Contents

1. Tawa a 83 4 START UP MANUAL IMPSEC 5000 INTRODUCTION Thank you for the trust you placed in us and in the equipment you just acquired With it you will be able to bring the most advanced technology in electro aesthetics and to introduce a tool that will become essential to secure good results This equipment provides you with an advanced option of body remodelling User friendly this equipment has been conceived to fully satisfy the requirements of the most demanding users This machine has been subject to tests on different subjects and facial and corporal areas to guarantee its quality and results Our company also provides practical and advanced courses in facial treatment technique This new service aims at giving the user the best knowledge possible in order to obtain high quality results Information on our courses is available in our web pages www ema es Before starting up the equipment please READ CAREFULLY this MANUAL Failing to do so could turn out to be dangerous and provoke damage to third parties We invite you to contact us or our distributor for any doubt or query We would be delighted to assist you Yours sincerely The Management EMA 5 START UP MANUAL IMPSEC 5000 SAFETY STANDARDS This equipment complies with the safety standards in force at the time of manufacturing However the following safety recommendations should be observed 1 Bef
2. second vibration effect around 90 movements per J second smoothing effect For some time physiotherapists have considered movement currents not completely effective in muscle treatment Recent investigation and research have shown the structure and the control of the motor nerve of a muscle to be much more complex than was thought Within a muscle are three types of fibres The motor nerve that controls each type of fibre communicates with different frequencies of pulses e Slow oxidation non fatigable stamina fibres constitute up to 50 of a muscle and are stimulated by frequencies of 6 to 15 pulses per second e Fast glycolytic oxidation the main strength fibres with a tendency to fatigue and tiredness Constitute up to 50 per cent of a muscle and are stimulated by frequencies of 20 to 45 pulses per second e Fast glycolytic fibres with explosive power fibres for sprinting jumping and high intensity activities Tire easily and are stimulated by frequencies of 50 to 70 pulses per second This obviously means that the machines providing a range of 40 to 120 pulses cannot fully stimulate all muscle fibres Some of the appliances using new generation movement currents have widened the range of low frequencies u to One pulse per second which means that they can create programs of various pulses and frequencies to work on all fibres of a muscle At a maximum of 120 pulses per second muscle forward stimulation is f
3. gt 4 2 4 1 2 2 4 N A N f 4B 4A _ 3B 3B 3A 2A 2B 2B 2A 1A a 1B 14 C 67 START UP MANUAL IMPSEC 5000 SYSTEM S 2B TREATMENT Toxin elimination REDUCTION EFFECT Lovver extremities and abdominal area S 2B SEQUENTIAL PROGRAM NC EMA 68 START UP MANUAL IMPSEC 5000 SYSTEM S 2B TREATMENT Toxin elimination REDUCTION EFFECT Lovver extremities and abdominal region FACIAL ANATOMIC ATLAS e Front view e Side view EMA 69 START UP MANUAL IMPSEC 5000 FACIAL ANATOMIC ATLAS FRONT VIEVV EMA 70 START UP MANUAL IMPSEC 5000 FACIAL ANATOMIC ATLAS N li Ui W i Se gt s 227 4 1 1 SIDE VIEW EMA 71 START UP MANUAL IMPSEC 5000 FACIAL FIRMING TREATMENT FRONT VIEVV EMA 72 START UP MANUAL IMPSEC 5000 FACIAL FIRMING TREATMENT SIDE VIEVV EMA 73 START UP MANUAL IMPSEC 5000 FACIAL FIRMING TREATMENT automatic plates V a FRONT VIEW EMA 74 START UP MANUAL IMPSEC 5000 FACIAL FIRMING TREATMENT automatic plates 7 Am SIDE VIEW EMA 75 START UP MANUAL IMPSEC 5000 ANATOMIC MAP OF FACIAL TOXIN ELIMINATION Amigdala faringea seccionada por la s nfisis M elevador de la esc pula M escaleno medio VISI N LATERAL Yuguloomohicideo Retrofaringeo Ami
4. 4 AS MANUFACTURERS we offer a 24 month guarantee on our equipments against any manufacturing fault In order for this guarantee to be efficient the following technical specifications must be taken into account 4 1 Minimum specifications in the electrical installation e The equipment must always be connected to the electrical current by means of a voltage regulator with ground point whose output voltage must be included between 110 and 120 volts in the case of installations with this voltage particularly in Latin American countries or 220 and 230 volts in European countries e The socket where the equipment is connected must be in perfect conditions 4 2 This guarantee becomes invalid if A The equipment is used improperly B The electrical installation or the regulator connected to the equipment are defective C The equipment is exposed to overloads short circuits electrical discharges floods or other similar unforeseeable circumstances D The equipment is handled or repaired by staff non authorised by EMA EMA 80 START UP MANUAL IMPSEC 5000 DECLARACI N DE CONFORMIDAD AT DECLARATION OF CONFORMITY DECLARATION CONFORMITE 89 336 CEE Electroest tica amp Mobiliario 73 23 CEE MARZO 2003 MARCH 2003 MARS 2003 Nombre del Fabricante BIOINSIDE INVESTIGACI N Y TECNOLOG A S L Manufacturer s name Nom du fabricant Direcci n del Fabricante Manufacturer s address Sant Mart de
5. On the muscle this current provokes a specific contraction of isothermal type accompanied by a slight effect of twist and turn of the muscular fibre On the subcutaneous cellular tissue it contributes to the mobilisation and resorption of interstitial liquids and tissues retained inside In addition stimulating the whole of the biological reactions favours the mobilisation of fat deposits On the circulatory system it favours return venous circulation and the reabsorption of the swelling These are the effects of IMPSEC 5000 on the human body The characteristics of this equipment allow to choose the most personalised choice of movement for the clients and their problems in each treatment The normal and the sequential movement normal can be Improves Iymph i en ern used apart or combined in the same session depending on the effect desired in each treatment EMA 48 START UP MANUAL IMPSEC 5000 SUGGESTIONS OF TREATMENT 1 NORMAL PROGRAM The application time is 30 minutes at the maximum intensity tolerated by the client During the session and throughout the treatment increase this intensity progressively to prevent the muscle fibres from getting used to the same electrical stimulus The plates must be placed on the body follovving the requirement of loss of adipose tissue and volume in another area Hovvever it is advised to vary their location on the client s body from one session to the next to tone
6. A EMA 61 START UP MANUAL IMPSEC 5000 SYSTEM S 1E TREATMENT Abdominal region REDUCTION EFFECT Abdomen waist thigh and lumbar region S 1E NORMAL PROGRAM EMA 62 START UP MANUAL IMPSEC 5000 SYSTEM S 1E TREATMENT Abdominal region REDUCTION EFFECT Abdomen waist thigh and lumbar region S 1F NORMAL PROGRAM 4B 63 START UP MANUAL IMPSEC 5000 SYSTEM S 1F TREATMENT Reafirmaci n REDUCTION EFFECT Back and arms S 1F NORMAL PROGRAM EMA 64 START UP MANUAL IMPSEC 5000 SYSTEM S 1F TREATMENT Firming REDUCTION EFFECT Bach and arms S 2A SEQUENTIAL PROGRAM 4 _ 9 3B 3A 2 2 2B 2A 1B 1A 1 65 START UP MANUAL IMPSEC 5000 SYSTEM S 2A TREATMENT Figure REDUCTION EFFECT Underarm back belly hip abdomen back waist S 2A SEQUENTIAL PROGRAM SQ L EMA 66 START UP MANUAL IMPSEC 5000 SYSTEM S 2A TREATMENT Figure REDUCTION EFFECT Underarm back belly hip abdomen back waist S 2B SEQUENTIAL PROGRAM IMPORTANT Two plates with four outlets are placed on the lower abdomen Connect the negative cables black to these plates and the positive ones red on the legs If the muscular contraction is excessive and troublesome invert the cables by placing the negative ones black on the legs and the positive ones black on the ovarian area 4
7. IMPSEC 5000 USER S MANUAL CE START UP MANUAL IMPSEC 5000 INDEX Ol MERC ML TT 5 ER Rx VPN 6 General DOMMES EVE PME 7 ecnmnmical Teatres u uu san kn S r b n TT 8 Protection system against mains failure ss 9 ACCOSSOLIGS iato x eai VINEA ER ERE VE EU samen meets 10 General description of the 16 11 SL Il juu M 16 PD OPE a C DU DERE EE 20 Options of treatment 1 Corporal passive gymnastics nnnm nnn 22 2 Corporal toxin nnn 24 3 Facial passive gymnastics and toxin elimination 37 Passive exercise aa aa aa ka ak aa ala a a aa a ka a a ala 28 Effects or Varlable CUITENUS li s seye xaleka SAR AWA ka Wan W S k kek 30 Effect of Movement k dad aka nA Pee 31 Passive gymnastics through electrical currents 32 Sinusoidal beauty 4 32 How
8. e It tones up the muscles which as we said is important to adopt a correct position It is also positive in cellulitis treatment since subjacent muscles are usually hypotonic e It stimulates the peripheral bloodflow due to muscle contractions which is useful in peripheral circulation troubles swelling heavy legs and cellulitis e It produces relaxation and a whole series of muscle contractions and physical exercises In people with insomnia passive gymnastics help to Sleep better e Finally it shares the general advantages of the exercise such as the feeling of well being euphoria strengthening general functional improvement of the organism Application time As mentioned in the previous paragraph passive gymnastics represents an alternative to traditional physical exercise but with a local application The application time of the IMPSEC 5000 equipment is conditioned by the client s characteristics and particularly its physical situation For this reason the professional must assess each case individually and control the client s evolution until possibly recovering muscle tonus Since muscle fibre has memory faster results will be obtained in people doing sport toning or exercise However consistency and a good diet are the indispensable allies for better results Passive gymnastics sessions must last about 20 30 minutes for the body and 10 15 minutes for the face The intensity of the current used must increase
9. However this conversion has a paradoxical effect on the human body since muscle is heavier than fat To control the results achieved the clients must be measured previously to the session of treatment Five outlines must be selected to this end breast waist hips thighs and upper knee Real loss of weight or volume in between sessions is a variable parameter that depends on the characteristics inherent to the client his her way of life and the food he she eats Therefore the difference between one session and the next is considered as weight or volume loss knowing however that there is always some recovery of the loss As a complement to the treatment it is recommended to urge the client to follow a proper food style according to their daily activity On the other hand products with a collagen action can also been applied capable of increasing the activity of the triglyceridolipase of the adipose cells whether through meso treatment penetration of cosmetics CEYA or other known techniques The sequential machine IMPSEC 5000 is an equipment of bioelectrical stimulation based on a low frequency alternating current with specific characteristics concerning the train of movement modulation Those characteristics make IMPSEC 5000 an indispensable ally in REDUCTION TOXIN ELIMINATION and CELLULITE treatments This appliance combines distinct work systems in a single module each one with defined effects The efficiency of the result
10. The nervous pulse crosses the layer of subcutaneous adipose tissue which is an insulant and therefore more or less power is needed to really reach the muscle s motor points Besides the fat there are other factors to consider such as the type of epidermis bone structure Another important factor to consider in order to obtain good results in passive exercise is the position of the plates These electrodes must be placed over EMA 30 START UP MANUAL IMPSEC 5000 the desired motor point s with precision so as to excite only those fibres of the motor branch that we are interested in In general only one muscle is excited if the plates are placed on the muscle s extreme motor points The entire muscle mass is excited if the plates are placed transversally to the cluster of muscles In order to locate the motor points consult the corresponding graphs since these points vary from one subject to the other For this reason it is best to locate them in an individualised way for each client using the diagrams The pressure exerted by the plates on the skin s surface during the treatment is vital for results If they are too loose the resistance that the contact surface presents increases and efficiency is reduced However as the objective of the application of the trains of movement is to improve blood flow if too much pressure is exerted the circulation is obstructed The plates acting as electrodes must meet certain conditions in
11. This contraction time can be set observing the indicators 10 since its control is independent from other buttons A lit indicator shows that the muscle is contracted e Controls the time during which the muscle remained contracted that is to say in tetany Mostly used for bodywork 7 Relaxation setting button e This button controls the time of relaxation that is to say the duration the pause betvveen contractions This time can be set observing the indicators 10 since its control is independent from other buttons The indicator turned off shows that the muscle is at rest e Controls the absence of contraction Mostly used for toxin elimination 8 Power control for the movement current 7 e Before connecting the plates to the client check that all controls M are on ZERO fully turned anticlockwise until hearing a click EMAG 15 START UP MANUAL IMPSEC 5000 Once the plates are located and the position of the other buttons selected PROGRAM CONTRACTION RELAXATION slowly turn the power control clockwise until getting an appropriate muscle contraction The position of this control depends on the muscle treated the position of the plates and the CLIENT Generally clients with a lot of subcutaneous fat need higher powers Once the power is set the client s comfort will be improved using the FREQUENCY control 5 In the first two outlets this button controls the micropulse current if the selector 8 is
12. Also be careful when you put the plates on the client and begin the treatment Always make sure that all the intensity controls are on zero before switching on the machine Afterwards gradually increase each control until the client feels a slight tingling sensation under each pair of plates IMPSEC 5000 is provided with a Safety device not allowing its operation until all the intensity buttons are on zero safety electric circuit x CONTRA INDICATIONS x People with a pacemaker Any type of muscle injury Do not apply on the abdominal region of pregnant women Do not apply on the hepatic zone of people with hepatic dysfunctions or lithiasis problems e Serious or non compensated circulatory troubles phlebitis thrombophlebitis important varices e The intensity of the contraction must never be painful Contractions being too intense may produce tears and muscle injuries EMA 51 START UP MANUAL IMPSEC 5000 TREATMENT GUIDE 1A NORMAL PROGRAM Reduction 1B NORMAL PROGRAM Figure 11 S 1C NORMAL PROGRAM Hips 12 S 1D NORMAL PROGRAM Buttocks 13 S 1E NORMAL PROGRAM Abdominal area 14 S 1F NORMAL PROGRAM Firming 15 S 2 A SEQUENTIAL PROGRAM Figure 16 S 2B SEQUENTIAL PROGRAM Elimination e pe EMA 52 START UP MANUAL IMPSEC 5000 S 1A NORMAL PROGRAM 24 26 A B Ta IB LA 18 1B IB 18 yu 53 START UP MANUAL IMPSEC 5000 SYSTEM S 1A T
13. en facial position 9 Connectors for the passive exercise outlets Each pair of plates must be connected to its corresponding outlet The plates must be located according to the treatment 10 Indicator of the contraction rhythm movement These eight indicators 10 are distributed on each power control on each outlet Regardless of the position of each plate the indicator remains lit during the contraction time programmed The indicator will light up when the muscle is contracted and remained off when the muscle is at rest 11 Safety light If the orange pilots lights up this means that there is a problem Safety circuit usually solved by placing all potentiometers on zero and turning off and on the machine 12 Display for the timer 13 Increasing the tens of minutes 14 Increasing the units of minutes 15 Button for activating or pausing time EMA 16 START UP MANUAL IMPSEC 5000 START UP 1 Before starting any treatment check that the main switch of the equipment 1 is off and that all output power controls 9 10 are on zero beyond the click of the incorporated switch It is very important to follow this procedure before placing the plates on the client for if all controls are not on zero and the plates are put the client may feel a sensation of tear in the muscles when turning on the main switch because of the uncontrolled transmission of the electric signal Such an imprudence may also lead
14. order to exert good electrical contact adapt themselves well to the body be hygienic etc There are many types each with its advantages and drawbacks Rubber plates have a resistance of several ohms which means that the power supplied on each point of contact with the treated surface reduces as the distance between the plate s point of contact and the treated surface increases This factor shows how important it is to place the plates correctly and makes them suitable for use in passive gymnastics treatments They cannot however be used for an unlimited length of time because the inside of the rubber contains carbon particles which gradually disappear For this reason the rubber gradually becomes insulating and the worn out plates must be replaced with new ones Finally another factor undoubtedly effecting the results in passive gymnastics is the type of electrical signal produced by the machine In this sense IMPSEC 5000 widely complies with the safety standards regarding insulation and the range of rectangular movements for which each train of movement produces a contraction The modulation of trains of movement allows to carry out an intensive or mild treatment The user can choose the rhythm of contraction as well as the frequency of the pulses contained in each train of movement to the value resulting the most comfortable EFFECTS OF VARIABLE CURRENTS The main action of these currents is represented in its effect on mus
15. progressively throughout the session to prevent the muscle from getting used to the electrical movement EMA 42 START UP MANUAL IMPSEC 5000 and to act as a stimulus for a greater toning of the muscle but vvithout a painful perception of the current for the client The sessions must take place two or three times per week for a treatment of 15 to 20 sessions or can even be followed everyday The professional opinion at individual level is decisive to determine the duration of a treatment Passive gymnastics can also be applied to retain good results once the treatment is over or for physical maintenance in general Locating the plates and the contact gel areas of the body to tone up depending on the problem to treat Apply a thin layer of conductor gel on the plates on the plates for a better transmission of the current to the human body D Applying IMPSEC 5000 is achieved locating plates on the EMA 43 START UP MANUAL IMPSEC 5000 BEAUTY TREATMENT IMPSEC 5000 The effect of IMPSEC 5000 on the tissues muscular and others can be observed from the first weeks of application An example is the reduction of a few centimetres and volume reduction although it is not only accompanied by a weight loss This volume reduction without weight loss is explained by the transformation of fat into muscle With the IMPSEC 5000 equipment the muscle fibre is stimulated in such a way that it ends up replacing the spaces occupied by fat
16. the passing of current and allow to adapt the electrical movement to the sensitivity and characteristics of each person User friendly it personalises each treatment and gives maximum comfort to the customer throughout the session The variety of electric signals makes bodywork treatments easier both on Superficial and deep plans and constitutes an ally for body remodelling treatment The improvement of muscle tonus helps the circulation valuable qualities of the beauty treatment with IMPSEC 5000 for people with venous problems The intelligent combination of these two currents contributes to the high level of the results While passive gymnastics work at muscle level isometric or sequential contraction helps eliminating naturally the toxins generated during passive gymnastics Incorporating both currents in the same apparatus makes of IMPSEC 5000 the ideal substitute to conventional pressotherapy equipments with a double use in a single machine The complementarity of the signals gives the necessary stimulus to carry out various treatments among which those linked with peripheral circulatory troubles body remodelling and toxin elimination EMA T START UP MANUAL IMPSEC 5000 TECHNICAL FEATURES Equipment of simultaneous and sequential movements Independent power control for each outlet Two outlets for the face and eight for the body Common frequency power control from 100 to 300 Hz Common contraction button Common relaxati
17. the plates specifically and by the sequential contraction of the muscles from foot to thigh EMA 40 START UP MANUAL IMPSEC 5000 Movement current in combination vvith other treatments Usually movement beauty treatment is used as part of a programme of treatments for the client More than one type of equipment can be included in the programme For instance galvanism through the body might be used as a preparation to movement beauty treatment By stimulating the biological reactions galvanism improves the response to the current of movement Machines are available which send both galvanic and movement currents IMPGA 5000 in the same pair of plates or separated electrodes After galvanism the current of movement is connected and will go on after the galvanic current has ended It is also interesting to combine Passive Gymnastics with the application of the CEYA technique Time of treatment The duration of a beauty treatment using movement is not critical For the method of plate location the treatment can last 20 minutes or so The manual method using passive gymnastics handles should produce at least 12 contractions in every muscle treated to be of any real value Phases of reduction by exercise Physical exercise is said to be a good means of reduction but that it is not as fast as that obtained only by some diets However once attained it is much more lasting than a diet We are going to study the evolution of the reduction
18. the sinusoidal current contracts the muscle 32 EC 33 Plates Electrode RED sean IL TENTE 33 Locating the plates on the client 33 Duration of the DUIS Cris sies kan ak Panic bd oe GOOD ace gaan 34 Freduencv or tne PUISOS EE EUCH DIMUS Sek 34 Timing the movements and intervals nennen nnn 36 Program or control TT TOQ s s salya aka er u uQ a dS A E Ra an ha ad Ra W n a 36 Fan OF MOVEMENES i yay TA rE dika WE W He WAN KER 36 xus kan kan Syn WAA W ra Wn ui Ka k 38 Beauty treatment technique with passive gymnastics 38 Physical effects of the beauty treatment with movement currents 39 Movement current in combination with other treatments 40 Tire or 525060 154 cat ex cms 40 Phases of reduction through 4 40 EMA 3 START UP MANUAL IMPSEC 5000 ADppDIICa tIGN UMG u 41 Location of the plates and contact 42 Beauty treatment vvith IMPSEC 5000 INGICAU DT 44 V COM 45 Cellulite formation 9 1 Ladder sance kaka aa 47 Suggestions OF treatment usu
19. to damage them the more the button of the relevant outlet is turned towards the right e If the orange pilot lamp 14 lights up check that all potentiometers are on zero Otherwise put them in that position Select the type of treatment you wish to perform and connect the plates to the client according to the treatment chosen adapting them with the relevant elastic bands For passive gymnastics a Facial option the movement is programmed for treatments in the facial tissues and muscles b Corporal option the movement is programmed for treatments in the body tissues and muscles The treatment area also determines the application format of the electrodes Mobile electrodes or fixed plates smaller than those used for the body can be used for facial treatments For body treatments we use oval rubber plates In one exclusive session of passive gymnastics it is possible to use only the rubber plates with a thin layer of conductor gel Connect the cables to their respective outlets 9 Prepare the client by applying conductor gel on the plates and placing them on the motor points corresponding to the muscles to be treated using elastic bands It is EMA 17 START UP MANUAL IMPSEC 5000 advisable to place the elastic bands on the body first and then slide the plates onto the motor points Last connect the cable to the plate 4 Check that the pressure and adaptation of the bands is correct 5 Turn
20. to the train of movements that tend to expect the contraction and will improve the effects of the current on the muscular tone Adapting these parameters allows to control the energy consumption level of the client To stimulate volume reduction in a defined area of the client s body induce a degree of caloric combustion similar to that which would be produced if the client was doing aerobics jogging for example Choose a rapid rhythm with little muscle contraction in tetany Using this option the muscle is induced to create an activity rhythm maintained around 120 pulsations per minute lasting a minimum of 30 minutes approximately and stimulating the combustion of the fatty tissues of the treated area If the aim of the client is muscle firming and toning the rhythm must be slow with a long phase of contraction in tetany This way muscle fibres are stimulated to increase their resistance and become stronger and more intense A good comparison for this type of beauty treatment is muscular training with weights This type of exercise works more intensely on specific groups of muscles with powers higher than any aerobic exercise The time of treatment can be less than during aerobics since the muscular surcharge is greater The recommended time is 20 30 minutes EMA 19 START UP MANUAL IMPSEC 5000 12 13 14 15 16 It is important for the beauty professional to define his objective and personalise as much as possi
21. u VERE K NA Wura Wn cues 48 18 189119 01216 a 49 Contraindications and 50 Treatment guide 1 S 1A NORMAL PROGRAM Reduction 52 2 S 1B NORMAL PROGRAM 54 3 S 1C NORMAL PROGRAM 56 4 S 1D NORMAL PROGRAM Buttocks 58 5 S 1E NORMAL PROGRAM Abdominal region 60 6 S 1F NORMAL PROGRAM Firming 62 7 5 2 SEQUENTIAL PROGRAM Figure 64 8 S 2B SEQUENTIAL PROGRAM Elimination 66 Fatial pL PIA 68 6 MEME 69 PEA LE 70 e Location of the motor points in manual passive gymnastics 71 e Location of the motor points in automatic passive gymnastics 73 Facial anatomic atlas of toxin elimination 8 e 75 e Location of the motor points in facial toxin elimination 76 Possible technical problems sexta tape kk ERO 78 Guarantee and SadleLy iissccocszcsaiakbi kk Oo RE RERO p DER ai E dor du a CRGO Ad ced quwaq 79 D claration Of CONTOMMITV y 0 y EYES Ne ERE NEGRO 80 Manufacturer S NO 81 D OO ES CIONS Els 82 Notes and
22. upper arms and shoulders the abdomen buttocks and thighs The underused muscles gradually stretch and when relaxed hang slack which results in a deterioration of the figure and adds extra centimetres to the measurements This together with a lack of response due to a reduced rate of the biological reactions within the muscles causes a ack of tonus An exercised muscle will remain under a certain tension even when relaxed That is when we can say that its tonus has improved By toning up flaccid muscles this way it is possible to reduce the measurements of the waist the hips the thighs and the upper arms and generally to firm and shape the figure Similarly toning up the muscles of the face and neck improve the facial features Many clients find it difficult to exercise their facial muscles themselves The effect of deliberately exercising a muscle whether by voluntary contraction Or passive gymnastics is to improve its biological reactions and its responsiveness This creates a demand for extra oxygen and energy foods and an increased output of cellular respiration waste which causes the dilation of the muscle capillaries and increases the blood supply The alternate contraction and relaxation of the muscle increases the movement of waste through the pumping action on the veins and lymphatic vessels Using modern machines such as IMPSEC 5000 peripheral venous circulation and toxin elimination of a leg can be stimulated by locating
23. 9 At the end of the treatment turn the power of each outlet slowly and to zero until hearing a click The treatment is then considered as completed IMPSEC 5000 COMBINES PROGRAMS No 1 AND 2 IN SESSIONS OF ABOUT 50 MINUTES EMA 27 START UP MANUAL IMPSEC 5000 3 Facial passive gymnastics and toxin elimination 1 2 3 4 The facial option additionally included in IMPSEC 5000 makes this equipment a valuable complement to facial treatments using only the first two outlets These outlets are located immediately below the switches for the face number 4 in the above photo For a facial add the optional plates to the equipment those plates adapt to the surface of the face They are not included in the equipment consult your nearest distributor Facial passive gymnastics can be done manually using specific handles or with small fixed plates However the option of toxin elimination is more limited and can be done using the fixed plates The procedure is the same as for the body except that switch number 4 must be set on FACIAL and that the treatment is limited to 4 plates only two plates on each outlet The professional with his knowledge of the anatomy must know where the passive gymnastics and evacuation points are on the face and adapt the treatment electrodes This manual however includes an anatomic map to serve as a guide during the treatment The duration of the sessions is shorter than EMA 28 START UP M
24. ANUAL IMPSEC 5000 for the body 10 minutes at most and the intensity of the movement is more moderated MILD option due to the absence of fat in the facial tissues PASSIVE EXERCISE CURRENTS Passive exercise currents are alternating currents of different forms presenting a variation of intensity in relation to time V Voltage V Voltage 1 second 2 seconds V Voltage V Voltage 1 second 2 seconds The characteristics of this machine allow to use muscular excitation in order to achieve the maintenance of muscle tone and muscular resistance with aesthetic ends This technique is known as passive gymnastics and its base is the production of muscle contractions similar to those of active exercise for body maintenance as much of the muscle system as of health in general for the cardiorespiratory stimulus that they provide Exercise has a very definite action on reduction by three different forms of application e it increases energetic expenditure e it increases basal biological reactions e and it reduces appetite EMA 29 START UP MANUAL IMPSEC 5000 The aim of passive gymnastics currents is to act on the muscle fibres and cause their contraction First we see an intuitive image of natural muscle contraction We are going to limit ourselves to the voluntary muscular contraction since there are also muscles that contract independently from the subject s will as for example the heart The m
25. MANUAL IMPSEC 5000 IMPSEC 5000 has an important diuretic effect MINIMUM RHYTHM LONG SEQUENCE LONG RELAXATION The combined use of these types of movements produced by the machine are recommended in cellulites treatments Scientifically Known as sclerotic degenerative oedematous panniculitis cellulitis is a unclearly defined modification of the connective tissue Whereas overweight is the simple accumulation of adipose tissue that does not usually provoke transformations in other tissues of the organism cellulites directly affects the cell membrane and becomes visible outside due to its anti aesthetic aspect EMA 47 START UP MANUAL IMPSEC 5000 Cellulite formation stages The first step in cellulitis is the slowing down in lymph elimination the connective tissue being flooded by this liquid simple congestive phase In the second phase of cellulitis the loose and flexible tissue thickens and acquires a more gelatinous consistency until falling into flakes This state provokes the irritation of tissue fibres which separate into fibrils producing a compact fibrous tissue oppressing the vessels and nerves and forming a barrier for vital exchanges This fibrous organisation is the direct cause of cellulitis which is localised in specific areas although there is a general dysfunction of the organism IMPSEC 5000 is efficient because it effects the subcutaneous cellular tissue the muscular tissue and the circulatory system
26. REATMENT Standard REDUCTION EFFECT Waist Delly hip thighs knee S 1A NORMAL PROGRAM EMA 54 START UP MANUAL IMPSEC 5000 SYSTEM S 1A TREATMENT Standard REDUCTION EFFECT Waist belly hip thighs knee S 1B NORMAL PROGRAM L c 4j 4B 4B as 4 Aj 3 c D 55 START UP MANUAL IMPSEC 5000 SYSTEM S 1B TREATMENT Figure REDUCTION EFFECT Underarm back belly hip abdomen back waist S 1B NORMAL PROGRAM EMA 56 START UP MANUAL IMPSEC 5000 SYSTEM S 1B TREATMENT Figure REDUCTION EFFECT Underarm back belly hip abdomen back waist S 1C NORMAL PROGRAM 2B EMA 57 START UP MANUAL IMPSEC 5000 SYSTEM S 1C TREATMENT Hip REDUCTION EFFECT Belly hip thigh knee half leg S 1C NORMAL PROGRAM EMA 58 START UP MANUAL IMPSEC 5000 SYSTEM S 1C TREATMENT Hip REDUCTION EFFECT Belly hip thigh knee half leg S 1D NORMAL PROGRAM 4 e 4A IB 4 GA 2B 2 2 e 28 2 1 Al 15 c A EMA 59 START UP MANUAL IMPSEC 5000 SYSTEM S 1D TREATMENT Buttocks REDUCTION EFFECT Belly waist thigh buttocks half thigh S 1D NORMAL PROGRAM Ld EMA 60 START UP MANUAL IMPSEC 5000 SYSTEM S 1D TREATMENT Buttocks REDUCTION EFFECT Belly waist thigh buttocks half thigh S 1E NORMAL PROGRAM 4 gt 2A 2A 2B D000 a
27. achieved through exercise We will note to clear phases what we call aesthetic reduction and ponderal reduction During the first week maybe fortnight the person doing passive or active gymnastics seems slimmer and slimmer but however they do not lose weight What happens in the organism Muscle toning forms muscles while reducing energy supply fat It is said that for each kilo of fat lost a kilo of muscle forms which is why there is no ponderal reduction But as fat weighs less than muscle there is on the other hand a loss of volume The person doing exercise loses weight progressively which can be seen if we measure the round of the arms waist hips thighs which will experience a progressive reduction even if a loss of weight has not been detected Furthermore passive gymnastics tones up the muscles which and gives a more aesthetic impression thanks to the back straightening reduction of the EMA 41 START UP MANUAL IMPSEC 5000 abdomen contour and elevation of the buttocks it provides Therefore the name we gave to that first phase aesthetic reduction Once the muscle is toned up the ponderal reduction really starts with a discreet pattern of weight loss from half a kilo a week but with a maintained loss and progressive stabilisation of the figure We must bear in mind that compared to the reduction by diet which only removes a few kilos reduction by physical exercise has other important advantages for maintenance
28. alisation maps of the plates are clearly indicated at the end of this manual Distribute the group of outlets 1 2 3 and 4 for the left leg and 5 6 7 and 8 for the right leg Window 2 corresponds to the right leg and window 3 to the left leg The four outlets on each window are numbered 1 2 3 and 4 from left to right EMA 25 START UP MANUAL IMPSEC 5000 We will only describe the first group since the operation of the second one is the same e Plug outlets 1 2 3 4 along the leg starting with number 1 closer to the foot e The order of the outlets 1 2 3 4 must preferably follow the direction of the return bloodflow 3 Turn the meter gently 8 until reaching the appropriate power The green lights 10 flash 4 Choose the CORPORAL option only applicable to the first tvvo outlets since the remaining ones by defect are exclusively corporal 5 Select the SEQUENTIAL program le 9 9 6 Select the position MILD or INTENSIVE L e Examine the client before selecting any option If there is abundant adipose tissue choose the INTENSIVE option The same option must be chosen when the objective is to tone up the muscle in depth e On the other hand choose the MILD option when the client has little adipose tissue The same option must be chosen when the objective is to tone up the muscle at the surface and when the circulatory effect has the priority over the firming effect 7 Activate a
29. ar less effective The motor nerves volts 0 EMA 36 reverse START UP MANUAL IMPSEC 5000 cannot transmit pulses much faster than this Hovvever because higher frequencies pass through the skin more easily and with less discomfort some machines are made using much higher frequencies of 400 600 and even 800 pulses per second With these frequencies it has been shown that the passive exercise current has no effect Instead they use an a ternating square wave current that has been shown by experiment to be effective Timing the movements and intervals IMPSEC 5000 controls the length of the stimulation period and interval Analysing the signal of the current in an oscilloscope we can observe which are the stimulation periods and the intervals as the following image shows These parameters can be personalised using rhythm and frequency controls stimulation period and interval and it is interesting to observe its effect hee n stimulation interval period In practice the control of the periods of passive gymnastics is enough to give a good contraction and the control of the interval enough to fully relax the muscle More time is really a vvaste of time in the treatment All muscles are programmed to contract and relax in synchronisation Program or control mode Some clients consciously or unconsciously dread the session and fight against the contraction which affects its full effect Program control or mode c
30. ble the performance of the IMPSEC 5000 to the concrete objective of the client e FREQUENCY frequency is a parameter of comfort for the client It enables to adjust the electric sensation to the tolerance and sensitivity threshold of the person receiving the beauty treatment It is also interesting since it enables to deepen the muscle treatment without altering or modifying the location of the passive exercise plates Increasing the frequency of the electrical movement can induce the activation of myofibril from lower groups of muscles that lower frequencies do not activate When choosing the frequency it is interesting to ask the client what sensation is produced in the various planes when modifying the frequency This subjective information helps the professional assess which muscles are most interesting to work on as target in the treatment To this end it is convenient to keep the frequency control on 5 and turn it on following the client s indications The dialogue with the client is very important in order to obtain the best results possible during the treatment Everyone has specific individual parameters hydric composition percentage of fat localisation of motor points etc which can lead to a mediocre acceptable or spectacular result The professional must find out these parameters and use them correctly to personnalise the use of the equipment When the time of the session is over reduce slowly and progressively th
31. cle mobilisation although logically they have other application effects that can broaden their operative range What we are mostly interested in is the mobilisation effect EMA 31 START UP MANUAL IMPSEC 5000 Effect of movement All living tissues are capable of reacting both to external actions and to modifications of the internal environment Irritability is a general characteristic of living matter Among all the tissues the nerve and muscle tissues are the most suitable to receive excitations and react this reaction being the contraction They are called excitable which means that they have excitability or are capable of responding to an energetic variation of the environment by an inner change this variation is called stimulus The relationship between the action of peripheral factors and the reaction of tissue is called state of excitability or state of excitation Normally the nerve cell is put into action by a single excitant There are several excitants capable of stimulation mechanical thermal chemical and electrical Electrical current is the best of these excitants Electrical excitation indeed presents many similarities with the majority of excitants it is easy to measure does not cause permanent changes in the elements that it crosses and above all puts into action minimal amounts of energy Other important effects of the variable currents apart from muscular excitability are e Improvement of the
32. d black outlets just below e Secondly this window identifies a member arm or leg during the elimination toxin program The emptying process is achieved using these four connections in each member connected EMA 11 START UP MANUAL IMPSEC 5000 3 THIRD WINDOW This window is used exclusively for body treatments Each meter controls the red and black outlets located below The operation of the outlets for the body is the same as for the potentiometers of the second window 4 FOURTH WINDOW This window allows visualizing the duration of the treatment and establishing the tens and units of minuts EMA 12 START UP MANUAL IMPSEC 5000 The on off switch and the fuse are found at the back of the machine Fuse e The fuse protects the appliance If necessary this element must be replaced by another with the same characteristics If possible call technical service 1 Main switch e The main switch is the ground connection that connects the appliance to the power supply 110 220 V The mains cable is connected to the contiguous base Before turning on the switch make sure that all power controls are on zero BEYOND THE CLICK of the incorporated switch 8 Once the verifications are made turn on the main switch The CONTRACTION light indicators will work after a few seconds according to the program chosen with switch 3 NORMAL or SEQUENTIAL 2 Main switch for contraction control in mi d intensive of the curr
33. e intensification and a mild decrease contracting and relaxing the muscle A movement current with a real train of movement The muscle and relaxes gradually contracts EMA 38 START UP MANUAL IMPSEC 5000 Polarity control As mentioned before the greatest obstacle to the passing of the current through the body is the resistance of the skin This resistance produces a sensation in the skin when the currents go through it For some customers this sensation is unpleasant sometimes unbearable when a sufficient amount of current passes to give satisfactory contractions Many units of movement current have a polarity control in mono or duo one phase or two phase In the position one or two phase a normal current of movement flows If changed to dual o two phase each alternating pulse is inverted and the ions vibrate easily forward and backward The resistance is less and therefore the sensation is reduced MOVEMENT CURRENTS WITH UNIQUE AND DUAL POLARITY a b dual polarity or two phase current unique polarity or one phase current Normal movement pulses all follow the same direction The movement of the ions the current only takes place in one direction The first pu se of a train of movements moves the ions easily it is a bit harder for the second one and SO on as the resistance increases In dual or two phase each alternating pulse is inverted and the ions vibrate eas
34. e power of each independent output until hearing a click The treatment is then considered as completed When doing a combined treatment of normal and sequential movement put all controls 8 to zero before removing the plates and disconnecting the equipment 1 Put the plates as indicated for the SEQUENTIAL movement program Activate the SEQUENTIAL program Modify the parameters of FREQUENCY 5 CONTRACTION 6 and RELAXATION 7 for the toxin elimination program EMA 20 START UP MANUAL IMPSEC 5000 17 Slowly increase the power for each outlet 8 18 When the time indicated has passed reduce slowly and progressively the power to the minimum until hearing a click The session is thus considered as completed 19 Afterwards remove and clean the plates N B WARNING THE HEART OR METALLIC ELEMENTS must not be found on the way from one plate to its pair IMPORTANT All plates used in every treatment must be carefully washed with soap and water at the end of each session The client can feel a sensation of heat and tickling in the treated area thermal rise and activation of the bloodflow during the session This is completely normal and shows that passive gymnastics has mobilised and activated blood circulation There must be total contact between the plates and the skin Hence the importance of a proper adaptation of the plates by means of the bands so that the pressure exerted by the bands is homogeno
35. en the client has little adipose tissue The same option must be chosen when the objective is to tone up the muscle at the surface and when the circulatory effect has the priority over the firming effect 7 Activate and adapt the setting buttons of FREQUENCY CONTRACTION and RELAXATION RECOMMENDATION mur FREQUENCY e Ask the client what sensation is created on its muscle and choose the frequency accordingly from O to 10 Also used to deepen progressively the signal of the electrical movement and to gradually from 5 to 10 tone up the muscle in depth d o CONTRACTION e For a volume reduction caloric consumption the contraction must be short from O to 5 e For toning up firming or muscle building the contraction must be long from 5 to 10 RELAXATION e In passive gymnastics the relaxation must be the mildest possible from O to 3 for a longer time of aerobics 8 Turn up the power of each outlet slowly and progressively until getting intense muscle contractions but not painful 9 At the end of the treatment turn the power of each outlet slowly and to zero until hearing a click The treatment is then considered as completed EMA 24 START UP MANUAL IMPSEC 5000 2 Corporal toxin elimination LT ee 1 Before starting any treatment make sure that the appliance is off with all controls on zero 8 2 Connect the plates to the client depending on the treatment to apply the loc
36. ent A of movements T1 e This switch increases the power shown on each output control of the current of movements On mild the spectre is included betvveen 1 and 10 If the intensity control is on intensive it vvill be included between 11 and 20 The autonomy of each output has EMA 13 START UP MANUAL IMPSEC 5000 a double intensity with this switch in order to adapt to the requirements of higher contractions e This switch orders the transmission of current to the customer when the INTENSIVE or MILD options are activated through the 8 outlets 9 It is possible to check the parameters of the selected current using the indicators 1 The type of program selected NORMAL or SEQUENTIAL 3 2 And the characteristics of the current the time of FREQUENCY 5 CONTRACTION 6 and RELAXATION 7 If button No 2 is set on INTENSIVE the equipment will provoke a greater effort from the muscle and the contractions will be somewhat sudden In MILD contractions will be more progressive 3 Button to select the NORMAL or SEQUENTIAL program A NORMAL PROGRAM B SEQUENTIAL PROGRAM e This svvitch enables to choose betvveen tvvo distinct programs Normal In this program the 8 outlets of the appliance provoke the contraction and relaxation at once The program is conceived to create the simultaneous contraction of all the selected muscles The time of contraction and relaxation are chosen on buttons 6 and 7 Seq
37. gdala lingual Submandibular Yugulodig strio Am gdala faringea Drenaje de grupo internodular infrahioideo Amigdala palatina Cervical profundo SIDE EMA START UP MANUAL IMPSEC 5000 FACIAL TOXIN ELIMINATION TREATMENT automatic plates V a E A FRONT VIEW EMA A START UP MANUAL IMPSEC 5000 FACIAL TOXIN ELIMINATION TREATMENT automatic plates 7 SIDE VIEW EMA 78 START UP MANUAL IMPSEC 5000 POSSIBLE TECHNICAL PROBLEMS 1 The machine is not working Why It can be a power cut or the treatment may be temporarily stopped eliminating the supply of current to the apparatus As the outlets are open IMPSEC 5000 activates a safety mechanism that lights up an orange pilot lamp This light shows that the current is completely sopped until all outlets have been shut and put to zero This safety system guarantees the total peace of mind of the professional against unexpected power cuts in the electricity supply safeguarding above all the client s safety Also check that the plug is connected properly and that tension reaches the appliance you can check the presence of current with another equipment Verify the rear connector and the reliability of the mains cable using it to connect another appliance It thus indicates that the problem does not come form the mains cable Once these verifications are made the protection fuse may be examined to see if it has
38. ily forward and backward The resistance is less and therefore the sensation is reduced Beauty treatment technique with passive gymnastics Passive gymnastics treatments aim at contracting specific muscles through the application of two electrodes in the appropriate position Each pair of electrodes stimulates determined muscles according to the person IMPSEC 5000 has 8 pairs of electrodes The type of current used is produced by groups of small movements With voluminous muscles and or muscles covered by fat layers the power of those movements must be increased in order to produce a contraction Although it highly depends on personal characteristics facial muscles usually require a much lower power than body EMA 39 START UP MANUAL IMPSEC 5000 muscles For this reason IMPSEC 5000 is provided vvith tvvo outputs vvith a option especially conceived for the face and a facial corporal power minimiser Physical effects of the treatment with movement currents Simply the purpose of beauty treatments using movement currents is to cause muscles to contract and relax alternatively to exercise them with no physical effort on the part of the client Hence the terms passive exercise or passive gymnastics Since no movement of the joints or limbs occurs it is an isometric exercise Its purpose is figure control by improving muscle tonus Because of their lifestyle most people make little use of their body muscles particularly those of the
39. l Erm 22 Adresse du fabricant E 08970 Sant Joan Desp BARCELONA SPAIN Declara que el producto Electrocosm tico Declares that the product Electrocosmetic D clare que le produit Electro cosm tique Nombre del producto IMPSEC 5000 Name of the product Nom du produit Marca EMA Brand Marque Cumple con la normativa Complies with the norm Est conforme la norme Seguridad El ctrica CLASS I TYPE BF Electrical Security UNE EN 60601 S curit lectrique Compatibilidad Electromagn tica Electromagnetic Compatibility Compatibilit lectromagn tique EN 61000 3 2 EN 61000 3 3 EN 50081 1 EN 55011 EN 5002 1 EN 61000 4 2 EN 61000 4 2 EN 61000 4 3 ENV 50204 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 EMA Signed Pilar Sanchez 81 START UP MANUAL IMPSEC 5000 MANUFACTURER S NOTE Our wish to offer to the aesthetic sector equipments that keep adapting to the requirements of this young profession leads us to conceive new equipments and to try and improve those already existing For this reason we are compelled to reserve the right to modify these specifications without prior notice All equipments are intended for a mains voltage of 230 V If you require it for a voltage of 125 V please inform your supplier at the time of order The inappropriate use not included in this instruction manual from the beauty professional can have undesirab
40. le results The manufacturer is not responsible for the results derived from an improper use of the machine EMA 82 START UP MANUAL IMPSEC 5000 SUGGESTIONS Your opinion is important to us You can send your comments and suggestions to get a better service day after day You can write at the following address EMA BIOINSIDE INVESTIGACION Y TECNOLOGIA S L REGISTRATION No B60829793 MAIN OFFICES AND MANUFACTURING Sant Marti de l Erm 22 Poligono Industrial Fontsanta 08970 Sant Joan Despi Barcelona Spain Tel 34 93 477 42 62 Fax 34 93 477 42 90 info ema es BARCELONA DELEGATION C Gerona 156 Bajos 08037 Barcelona Spain Tel 34 93 459 18 54 Fax 34 93 459 11 32 barcelona ema es National number 902 31 51 71 International number 34 93 477 42 63 EMA 83 START UP MANUAL NOTES AND COMMENTS EMA IMPSEC 5000 START UP MANUAL EMA BIOINSIDE INVESTIGACI N Y TECNOLOGIA S L Sant Mart de l Erm 22 Poligono Industrial Fontsanta 08970 Sant Joan Desp Barcelona Spain Tel 34 93 477 42 62 Fax 34 93 477 42 90 IMPSEC 5000 info ema es EMA 85
41. lectrodes Electrodes need a conducting agent to transmit the current through the skin Modern body electrodes are made of plastic impregnated with carbon that makes them electrically conductive with no need to apply water or salt as it was done in the past A thin layer of conductor gel must be applied between the plate and the skin in order for the current to overcome the electrical resistance of the skin and penetrate inside Locating the plates on the client Most equipments using movement current are multi output machines that can work with several pair of electrodes simultaneously Electrodes must be used jointly with their homologous pairs to obtain complete circuits Nevertheless there are a number of methods of application of these pairs of plates EMA 34 START UP MANUAL IMPSEC 5000 In duplicate motor plate location the pair of electrodes is placed in the motor points of two adjacent muscles The current only has a short path through the body from one electrode to the other Another pair of plates is normally applied in the corresponding muscles in a different part of the body In separated plate location one plate is put on the motor point of a muscle and its homologous pair is placed on the equivalent muscle on the other part of the body This method is not recommended Longitudinal plate location is useful where the motor point of a muscle is not easy to locate One plate is placed near its origin and the other near the i
42. me type of frequency up to 100 pulses per second are introduced in the organism they must also be captured by the motor nerves and generate a muscular contraction EMA 33 START UP MANUAL IMPSEC 5000 Nevertheless nature conscientiously tries to prevent this factor The high resistance of the skin prevents our bodies controlling other people s bodies merely by touching Also each nerve is isolated by a fat myelin sheath This means that first exterior pulses must have a fairly high voltage in order to cross the skin and secondly they must be directed to the motor points of the muscle so that this detects them easily The motor point is the point of the muscle where the motor nerve enters The electrodes must be carefully placed so that the flow of current through the body is produced in this motor point While the current passes the muscle contracts and remains contracted The current decreases and the muscle relaxes The muscle can be stimulated so that it contracts and relaxes alternately through the adjustment of the current Owing to the high resistance of the skin WI applying a sufficient current to develop an effective treatment can generate a stimulation interval characteristic sensation in the client t period Electrodes In order to complete the circuit through the client the passive exercise current is applied through electrodes Plate e
43. nce of adipose tissue select the INTENSIVE position using the button 2 The square modulation of the current triggered by this converter has a greater penetration power than the exponential modulation activated on MILD Before choosing the INTENSIVE position put all power controls 8 to zero and once the square EMA 18 START UP MANUAL IMPSEC 5000 modulation is activated increase slowly and progressively the power of each outlet 11 Once the client s muscles are used to the programmed contraction gradually increase the power of each outlet so that the intensity of the contraction will be higher but painless for the client At the same time adapt the parameters of FREQUENCY 5 CONTRACTION 6 and RELAXATION 7 People used to doing sport will adapt to the electrical movement more easily than those who do not do sport regularly Setting the intensity can be done every 10 minutes on average The pilot lamp will light up when current passes visually indicating the rhythm and frequency of the movement received by the client The combination between contraction and relaxation gives us variants of treatment A slow rhythm is obtained by creating more relaxation than contraction A fast rhythm is obtained by doing the opposite The rhythm must be slow at the beginning and become more intense as the session goes always remaining comfortable for the client The progressive variation of the rhythm will avoid the habituation of the client
44. nd adapt the setting buttons of FREQUENCY CONTRACTION and RELAXATION RECOMMENDATION mmr FREQUENCY e Ask the client what sensation is created on its muscle and choose the frequency accordingly from O to 10 e Also used to deepen progressively the signal of the electrical movement and to gradually from 5 to 10 tone up the muscle in depth EMA 26 START UP MANUAL IMPSEC 5000 e For toxin elimination the professional must decide if the client requires a beauty treatment of deep or superficial veins and set the button accordingly O superficial veins 10 deep veins CONTRACTION e The contraction must be extended to ensure a pump effect from the furthest to the nearest position from 8 to 10 RELAXATION 9 In the toxin elimination program the relaxation must be the littlest possible from 7 to 10 in order for the toxins to be dragged towards the lymph glands 8 Turn up the power of each outlet slowly and progressively until getting intense muscle contractions but not painful e We can observe that as shown on the light indicators the CONTRACTION of the lowest part of the leg takes place first e The contraction follows with outlet 2 3 and finally 4 higher leg That is to say the contraction is transmitted upwards straining the muscle and favouring return circulation When the contraction cycle is over the RELAXATION cycle starts relaxing first outlet 42 and then being transmitted downward
45. not meted Finally make sure that the mains voltage corresponds to that of the equipment If the pilot light is on but the machine is not working check with this start up manual that the operation process is the right one If the problem persists consult the technical department 2 An outlet is not functioning What is happening If an outlet is not functioning properly or not functioning at all it can mean that the cable has been cut internally which blocks the current output The problem is solved by replacing the cable by a new one 3 The client has no electrical sensation What can it be Make sure that the plates are correctly soaked with conductor gel and are homogenously adapted to the client s skin The lack of a proper contact can produce the absence of electric transmission EMA T9 START UP MANUAL IMPSEC 5000 GUARANTEE AND SAFETY 1 The manufacturer is not responsible for an improper use of this machine or for the consequences derived from it Any use not included in this instruction manual can be dangerous We therefore ask you to consult your nearest authorised distribution centre for any doubt 2 Our wish to include possible improvements in our appliances compels us to reserve the right to modify the characteristics of our equipments without prior notice 3 All equipments are provided for a mains voltage of 230 volts If you require a voltage of 125V notify it to your provider at the time of the order
46. nsertion of the same muscle The current has to pass the motor point On the face where a number of motor points are close together conventional plate application is not possible or at least difficult Duration of the pulse Normally every brief and intense passive exercise pulse lasts 0 3 milliseconds about 3 10 000 of a second IMPSEC 5000 has a control system for the duration or amplitude of the movement allowing maximum control of the electrical pulse Pulse duration amplitude 0 MOVEMENT DURATION OR AMPLITUDE IN MOVEMENT PULSES Frequency of the pulses IMPSEC 5000 includes a button allowing to control the frequency included between 40 and 120 approximately Alternatively there is also a mild intensive switch Controlling this buttons and switches different sensations can be produced in the client The numbers correspond to the frequency of pulses per second EMA 35 START UP MANUAL IMPSEC 5000 A pulse frequency of 40 60 pulses per second produces a vibratory contraction of the muscle This is known as incomplete tetany in the muscle or vibratory effect The muscle vibrates because it has time to relax a little before the next contraction Turning up the frequency to around 90 pulses per second produces a steady contraction a complete tetany or a smooth effect The muscle does not have time to relax between one pulse and the next a around 50 movements per
47. on button Supply voltage 230 V 110V on request Input 45 W Weight 8 Kg Dimensions 420 x 320 x 140 mm Ground connection provided with a ground connection through its mains cable Connect to installations equipped with that connection Safety it remains insulated from the mains through a coil transformer This symbol indicates an established risk The voltage applied to the outlet is over 10 Khz This symbol aims at dissuading the use of the apparatus by personnel non qualified or newly introduced to its use warning of the possible adverse effects that an improper use could provoke on the client This equipment provides a special protection rate against electrical discharge particularly in relation with the authorised leakage current and the reliability of the earth connection However the part applied to the client is insulated from all other parts of the equipment with a protection rate higher than that established for the classification of the machine as BF type EMA START UP MANUAL IMPSEC 5000 PROTECTION SYSTEM AGAINST MAINS FAILURE This machine includes a protection system against mains failure In case of power outage the machine will stop Once the current has been restored the protection circuit will be activated The machine will then block the outlets interrupting the treatment and the orange pilot light will light up To resume the treatment put all power controls to zero Once the protection circ
48. on the switch 1 Check that the green light 13 flashes 6 Select the NORMAL or SEQUENTIAL program 7 Select the MILD or INTENSIVE position 8 Turn on and set the buttons of FREQUENCY 5 CONTRACTION 6 and RELAXATION 7 9 Turn on the power controls of the movement outlets 8 e Start with a low level to observe the client s reaction to the passing of the electrical movement After a few minutes turn the intensity up progressively so that the muscle does not get used to the same type of contraction and repeat the operation throughout the session The muscular contractions must be intense but not painful The indicator 10 will show the rhythm of transmission of the movement current e If the client feels a slight tickling gently move the plate until the sensation disappears since we are working on two or more motor points at the same time 10 The intensity of the electrical movement can be modified or personalised using the MILD or INTENSIVE switch 2 following professional criterion It is recommended to begin with MILD and observe the person s tolerance threshold Mild option the electric signal stimulates preferably superficial muscles b Intensive option the electric signal stimulates preferably in depth muscles The intensive option is also advised in people with abundant adipose tissue in the area to be treated e If the motor point of the muscle is located in depth as a result of the prese
49. ore handling the equipment read carefully this manual 2 Do not use on customers with a pacemaker or any other active implant for the risk of interference with this device 3 This appliance produces low frequency currents The heart must not be found on the path of the galvanic current 4 There must not be metallic elements e g osseous prosthesis and or cables in the area subject to the treatment 5 Always place the accessories when the power button indicates zero 6 This equipment must be used following the instructions of qualified personnel for example graduated beauticians 7 The client s electrical safety is ensured by a double insulation from the mains Do not however connect to a socket deprived of an earth connection WARNING This equipment is not a medico sanitary product not aiming at diagnosing controlling monitoring or relieving any disease injury or deficiency Always use cosmetic products complying with the law in force In case of doubts concerning the application on a specific client consult a specialist EMA 6 START UP MANUAL IMPSEC 5000 GENERAL POINTS IMPSEC 5000 is a passive exercise appliance based on a low frequency alternating current that combines in one machine the simultaneous movement with the sequential movement of toxin elimination IMPSEC 5000 has eight outlets allowing to connect 16 plates in corporal mode and four in facial mode A full informative light system indicates
50. otor muscles are made of groups of cells called muscle fibres that have the possibility to contract The contraction of these clusters of cells is produced when it is ordered by the nerve in contact with each muscle fibre in a message sent by the brain This order is translated into an electrical tension generated by the body in a natural way Nevertheless can this nervous pulse be reproduced artificially The answer is yes The technique gives us the possibility to induce the contraction of a muscle through the application of a current produced by a machine If the machine produces the adequate electrical signal this will be dealt with by the muscle in a similar way to the order of contraction that the nerve conveys in a natural movement The muscular mobilisation produced by this appliance nevertheless has differences with the natural functioning of the muscle These differences are the following Firstly the appliance is far less precise than the natural functioning Instead of having thousands of minute electrodes over each muscle fibre as nerve endings do we only have several pairs of plates acting as larger electrodes and connected externally to the skin From these differences between the natural functioning and the movement of the appliance we can deduce that the client s characteristics are essential to the approach of the treatment since the passive gymnastics current produced by the machine does not act directly on the muscle
51. peripheral return circulation which helps to eliminate waste products e Stimulation of the local biological reactions where the muscular excitation takes place with which overweight cellulites flabbiness etc can be treated EMA 32 START UP MANUAL IMPSEC 5000 Passive gymnastics through electrical currents When an intense and sharp electrical movement passes through the body the muscles in its way contract in response An electrical current flowing as a not too fast series of pulses will make the muscles contract and remain contracted during the time that the current flows 1 A direct interrupted current in the form of a series of small sharp pulses through the body is called movement current Sinusoidal beauty treatment a rupture takes place forward Primary current input volts 0 i i t I i backward Movements Current as shown on created forward forward ba d Secondary current output an oscilloscope t Passive exercise current volts 0 backward Pulses of inverted rupture are the functional part of the movement current How the sinusoidal current contracts the muscle When we consciously decide to move the brain sends electrical messages through motor nerves to those muscles that will be contracted to create movement The electrical messages from the brain consist of a series of electrical pulses AS soon as external electrical pulses of the sa
52. reates a differentiated and random transmission of current making it difficult for the client to anticipate the moment of the next contraction It is convenient to vary and intensify the frequency and rhythm parameters Train of movements The series of pulses producing movements or a stimulation period is known as train of movement The nature of the contraction can vary according to the individual strength of the pulses creating the train of movements EMA 37 START UP MANUAL IMPSEC 5000 A train of movements too abrupt and aggressive with pulses of the same intensity tends to create an unpleasant feeling of heartrending contraction This happens because the first few pulses of the same intensity move more freely through the skin for its intensity gradually builds and for this reason they are more effective at the time of contraction Therefore the first pulses of each train of movements are of lower intensity and gradually increase This effect can be observed by means of an oscilloscope T The first movements of the train 4 of movements are of lower intensitv to avoid a tear Passive gymnastics equipments can produce an increasing train of movement to contract the muscle more and more along the train of movements and suddenly relax when the train of movements stop Triangular train of movements as shown on an oscilloscope Other machines produce a gradual train of movement based on the progressiv
53. s obtained depends on the isolated or joint use of the type of currents generated by IMPSEC 5000 normal isotonic or sequential isometric movements EMA 44 START UP MANUAL IMPSEC 5000 The normal movement produces a maintained and simultaneous muscular contraction with all the plates On the contraction this type of stimulus has a FIRMING and toning effect on the muscle fibre Furthermore for the characteristics of the type of contraction created it has a reducing effect Since it produces the important increase of the activity of the muscle fibre which accelerates the activity of the lipids and help mobilising the fat deposits of the organism STEP 1 of the treatment STEP 2 of the treatment INDICATIONS Overweight Localised and diffused cellulite Circulatory problems swelling heaviness Flabbiness Physical keep fit EMA 45 START UP MANUAL IMPSEC 5000 SYSTEMS There are tvvo different systems of treatment e System 1 e System 2 SYSTEM 1 MINIMUM RHYTHM SHORT CONTRACTION Il j SYSTEM 2 MINIMUM RHYTHM LONG CONTRACTION The sequential movement produces a sequential contraction in a centripetal direction that favours interstitial liquid resorption and efficiently activates lymphatic and venous circulation This produces the systematic ELIMINATION with liquid surcharge towards the organic filters Hence the subsequent diuretic effect EMA 46 START UP
54. tment 15 20 sessions Pattern 2 3 sessions per week SEQUENTIAL PROGRAM CIRCULATORY PROBLEMS e Sequential movement toxin elimination Duration of each session 15 minutes Duration of the treatment 10 15 sessions Pattern 1 2 sessions per week NORMAL PROGRAM Y SECUENCIAL COMBINADO CELULITIS e Movimiento normal Movimiento secuencial Duration of each session 50 minutes MOVIMIENTO NORMAL 30 minutes MOVIMIENTO SECUENCIAL 20 minutes Duration of the treatment 10 15 sessions Pattern 1 2 sessions per week The application of the sequential equipment IMPSEC 5000 is done locating the plates in specific areas as shown in the following graphs Apply the neutral conductor gel on the plates to favour the transmission of the current to the human body The application of the plates must vary according to the requirements of each moment following a criterion of location per area This way the most appropriate location for each phase of the treatment is chosen during each session See the graphs at the end of this manual to identify the different locations of the plates EMA START UP MANUAL IMPSEC 5000 Contraindications and precautions The contraindications of the beauty treatment with IMPSEC 5000 are the same as for a general treatment An additional precaution is that you should avoid applying the treatment in an area close to the heart The current could act as a pacemaker and effect the cardiac contraction
55. uential In this program the 8 outlets are divided in two groups of 4 The left side can be treated with one group and the right with the other group We can observe the operation on the indicators and modify the contraction and relaxation time using buttons 6 and 7 This is conceived to provoke the progressive contraction of each extremity of the body more similarly to natural movements 4 Facial corporal selector e Only the first two outputs 4 provided with this button In corporal position these two outlets are identical to the other six On facial they become micromovements and reduce the power of the maximum movement by half in corporal mode EMA 14 START UP MANUAL IMPSEC 5000 In FACIAL position the povver of the movement is reduced by half to adapt to the facial muscles Thanks to this intensity limitation the movement coming from these outputs is Suitable for facial treatments The action of these controls is limited to the first two outputs In CORPORAL position this output works similarly to the rest 5 Frequency main switch for movement currents comfort button by choosing the frequency NES ZI e This button controls the contraction frequency of the movement of vn IN the current to adapt the current to the sensitivity of the client and to give him the most pleasant sensation possible 6 Contraction setting button t t e This button sets the duration of movement contraction longer or 9 shorter
56. uit has been deactivated the orange pilot light 11 will go out and the green lights 10 will light up again EMA 9 START UP MANUAL ACCESSORIES REF DESCRIPTION OTY 5111058 Oval silicone plate 1 inlet 16 5111059 Oval rubber plate 4 inlets 4 5151060 banana cable Set 8 5111029 Grey elastic band 40 cm 2 5111030 Grey elastic band 60 4 5111028 Grey elastic band 80 cm 2 210056 Normal mains cable 1 PHOTO REF DESCRIPTION 5111058 Oval silicone plate 1 inlet 5111059 Oval rubber plate 4 inlets 5151060 Red black banana cable set 5111029 Grey elastic band 40 cm 5111030 Grey elastic band 60 cm 5111028 Grey elastic band 80 cm 210056 Normal mains cable EMA IMPSEC 5000 10 START UP MANUAL IMPSEC 5000 GENERAL DESCRIPTION OF THE CONTROLS IMPSEC 5000 includes 4 different windows 1 FIRST WINDOW This window includes the elements common to all the outlets of the equipment 2 SECOND WINDOW This window has two basic functions e First it includes two outlets allowing to carry out the treatment for facial and body tissues These outlets are the first two and are located just below these switches The meters controlling them can be found vertically each meter controls the red an
57. up the whole muscle NORMAL PROGRAM REDUCTIVE AND FIRMING Normal movement passive gymnastics Duration of each session 20 minutes Duration of the treatment 15 20 sessions Pattern 2 3 sessions per week SEQUENTIAL PROGRAM The application time is minutes at the maximum intensity tolerated by the client However when the day of the treatment corresponds with the menstrual cycle do not apply the sequential movement on the abdominal region Hypersensitizing produced by menstrual troubles could induce pains in the ovarian area due to the passing of the current It is not recommended therefore to place the plates onto this area during the period Nevertheless the plates can still be applied onto the lower extremities for toxin elimination SEQUENTIAL PROGRAM CIRCULATORY PROBLEMS Sequential movement toxin elimination Duration of each session 15 minutes Duration of the treatment 10 15 sessions Pattern 1 2 sessions per week 3 COMBINED PROGRAM 1 2 COMBINED NORMAL AND SEQUENTIAL PROGRAM CELULITIS Normal movement sequential movement Duration of each session 50 minutes NORMAL MOVEMENT 30 minutes EMA 49 START UP MANUAL SEQUENTIAL MOVEMENT 20 minutes Duration of the treatment 10 15 sessions Pattern 1 2 sessions per week Summary NORMAL PROGRAM REDUCTIVE AND FIRMING e Normal movement passive gymnastics Duration of each session 20 minutes Duration of the trea
58. us in the whole surface of the plates The skin is the most resisting organ of our organism In order for the current to go inside a contact gel has to be applied between the passive exercise plates and the skin This contact gel can be neutral and without specific properties A geloide product with firming or reducing properties can also be applied without altering the treatment EMA 21 START UP MANUAL IMPSEC 5000 OPTIONS OF TREATMENT Corporal passive gymnastics Corporal toxin elimination Facial passive gymnastics and toxin elimination E EMA 22 START UP MANUAL IMPSEC 5000 i Corporal passive gymnastics 90995 1 1 Before starting any treatment make sure that the appliance is off with all controls on zero 8 2 Connect the plates to the client depending on the treatment to apply the localisation maps of the plates are clearly indicated at the end of this manual 3 Turn the meter gently 8 until reaching the appropriate power The green lights 10 flash 4 Choose the CORPORAL option AR for outlet 1 and 2 only 5 Choose the NORMAL program 9959 6 Choose the position MILD or INTENSIVE L e Examine the client before selecting any option If there is abundant adipose tissue choose the INTENSIVE option The same option must be chosen when the objective is to tone up the muscle in depth EMA 23 START UP MANUAL IMPSEC 5000 On the other hand choose the MILD option wh

Download Pdf Manuals

image

Related Search

Related Contents

LG 50PN450P plasma panel  取扱説明書 [PDF形式]  動 と 静 を 自 在 に 操 る 、 ホ ー ム サ ー バ P C と い う  ICF-CD2000    USER MANUAL - Skateboard China    DEWALT DCS330L Use and Care Manual  Canon 4454B001 Camcorder User Manual  2 Säulen Hebebühne  

Copyright © All rights reserved.
Failed to retrieve file