Home

"user manual"

image

Contents

1. 17 4 BEFORE YOU BEGIN What is included 1 xMini Spot wash User Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton checkthe contents to ensurethat all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection ifany parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the eventthat a fixture must be returned to the factory itis important that the fixture be returned in the original factory box and packing AC Power This fixture used switch power supply it can transform by itself when user input power Safety Instructions Please readthese instructions carefully it includes important information aboutthe installation usage and maintenance ofthis product Please keep this User Guide for future consultation If you sell the unit to another user be sure that they alsoreceive this instruction booklet Always make sure that you are connecting to the proper voltage and thatthe line voltage you are connecting to is not higher than that stated the decal or rear panel of the fixture This productis intended for indoor use only To preventrisk offire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the uni
2. CHER MUNMANMEMEMMM ewan 4 OPERATING INSTRUCTIONS U onnan 10 NAVIGATING THE CONTROL PANEL f er ame rar E RE earn 2 10 MAE crie rectas eere EM PUN ie wee 11 USER CONFIGURATIONS a USER CONFIGURATIONS 12 To set thepan to invertingor non inverting 212 To set thetilt to inverting or non inverting sas 12 To set the LED Readout tolnverting or Non Inverting I 12 To set the DMX channel configuration I I LLLI 12 To set the maximum pan wes 12 To set the maximum tilt angle Service Functions To reset the fixture To restore allsettings to theirfactory defaults 12 OPERATION UCM eee d Stand Alone Mode Sound Active Auto MEME uu UU U UU Uli 13 Master Slave Mode Master Sound Master Auto s DMX Mode DMX CHANNEL VALUES 13 CHANNEL FOR SPOT 14 DMX CHANNEL VALUES 12 CHANNEL FOR WASMD s u S l UU SS LU U 15 DMX CHANNEL VALUES 5 ORL VES 2 SE 7 1 1 uu ous 16 DMX CHANNEL VALUES 4 CHANNELFOR Se o m I ll 16 5 APPENDIX RT TECHNICAL SPECIFICATIONS c Met ceo
3. Setting up a DMX Serial Data Link 1 Connectthe male 3 pin connector side of the DMX cable tothe output female 3 pin connector ofthe controller 2 Connectthe end of the cable coming from Universal DMX Controller the controller which will have a female 3 pin connectorto the input connector of the next fixture consisting ofa male 3 pin connector 3 Then proceed to connect from the output as stated above to the input of the following fixture and so on This drawing providesa general illustration ofthe DMX Input Output panel of a lighting fixture DMX Data Cables Order Code Description DMX1 5 DMX Cable 1 5m 4 9ft DMX4 5 DMX Cable 4 5m 14 8ft DMX10 DMX Cable 10m 32 8ft Continue the link 8 Master Slave Fixture Linking 1 Connectthe male pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector ofthe nextfixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and soon Often the setup for Master Slave and Standalone operation requires that the firstfixture in thechain be initialized for this purpose via eithe settings in the control panel orDIP r switches Secondarily the fixtures DMX IN DMX OUT DMX IN that follow maya
4. Color Movement Macros 000 007 NoFunction 008 lt 022 Auto Program 1 023 037 Auto Program 2 038 052 Auto Program 3 Auto Program 4 Auto Program 5 Auto Program 6 Auto Program7 AutoProgram 8 SoundActive1 SoundActive 2 SoundActive 3 SoundActive 4 SoundActive 5 SoundActive 6 SoundActive 7 SoundActive 8 15 DMX Channel Values 5 Channel for Spot CHANNEL VALUE FUNCTION 000 255 000 255 Tilt Dimmer Strobe 000 007 Closed 008 lt 134 100 0 3 135 239 Strobe slow fast 240 255 Open Color Macros 000 007 NoFunction 008 021 White 022 034 Red 036 049 Green 050 063 Blue 064 077 Cyan 078 091 Magenta 092 105 Yellow 106 119 Purple 120 133 Orange 4 134 147 Chartreuse 148 161 Pink 162 175 Brown 176 189 Gold 190 203 Crimson 204 217 Violet 218 231 Crape 232 255 Color Change Macro1 ee 8 15 16 23 24 31 32 39 600090 40 47 48 55 56 63 64 71 72 79 80 94 GOBO1 Shake from slow to fast 95 109 GOBO2 Shake fromsiow to fast 110 124 GOBO3 Shake from slowto fast 125 139 GOBO4 Shake from slow to fast 140 154 GOBOS5 Shake from slow to fast 155 169 GOBO6 Shake from slow to fast 170 184 GOBO7 Shake fromslow to fast 185 199 GOBO8 Shake frcm slow to fast 200 214 GOBO9 Shake irom slow to fast 215 235 Positive rainbow effectwith increasing speed 236 255 Negative rainbow effectwith increasing spe
5. or DMX ADDITIONAL FEATURES User selectable basicor advanced operating modes User selectable pan tilt ranges Pan 540 360 180 Tilt 270 180 90 Compact and lightweight LED display menu with invert 9 Reset tofactory settings option Display auto on off Pan tilt invert option Fan cooled OPTIONAL CONTROLLERS Easy Controller CA 9 DMX Channel Summary 13 Channel Mode for Spot 12 Channel Mode for Wash CHANNEL FUNCTION CHANNEL FUNCTION 1 Pan 1 Pan 2 PanFine PanFine 3 Tilt Tilt 4 Tilt Fine Tilt Fine 5 Vector Speed Pan Tilt Vector Speed Pan Tilt Dimmer Strobe 6 Dimmer Strobe 7 Red 8 Green Color Macros Color Macros 11 Vector Speed Color 12 MovementMacros 12 Movement Macros 13 Gobo DMX Channel Summary 5 ChanneI Mode for Spot 4 Channel Mode for Wash CHANNEL FUNCTION CHANNEL FUNCTION Dimmer Strobe Color Macros Dimmer Strobe Color Macros Product Overview Projector Head Focus Control Panel LED Readout DMX Out IEC Power Connector with Fuse holder Rear Voltage Selector CA 9 Switch Controller rear Input rear 3 SETUP Disconnect the powercord before replacinga fuse and always replace with thesame type fuse Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing Remove the damaged fuse fromits holder and replace wi
6. 92 105 Yellow 106 119 Purple 120 133 Orange 134 147 Chartreuse 148 161 Pink 162 175 Brown 176 189 Gold 190 203 Crimson 204 217 Violet 218 231 Crape 232 255 Color Change Macro 1 Vector Speed Color Movement Macros NoFunction Auto Program 1 Auto Program 2 Auto Program 3 Auto Program 4 Auto Program 5 Auto Program 6 Auto Program 7 AutoProgram 8 SoundActive1 SoundActive 2 Sound Active 3 Sound Active 4 Sound Active 5 Sound Active 6 Sound Active 7 SoundActive 8 Gobo e 8 15 16 23 24 31 32 39 eee 40 47 48 55 56 63 64 71 72 79 9 8 80 94 GOBO1 Shake 95 109 2 Shake 110 124 GOBO3 Shake 125 139 GOBO4 Shake 140 154 5 Shake 155 169 GOBO6 Shake 170 184 GOBO7 Shake 185 199 GOBO8 Shake 200 214 GOBO9 Shake 215 235 Positive rainbow effectwith increasing speed 236 255 Negative rainbow effectwith increasing speed 14 DMX Channel Values 12 Channel for Wash CHANNEL VALUE FUNCTION 1 2 men Pan Fine 4 m Tilt Fine 5 000 255 Vector Speed Normal Slow Dimmer Strobe 000 007 Closed 008 134 100 096 135 239 Strobe slow fast Open Red 0 100 Green 0 100 Blue 0 100 Color Macros NoFunction White Red Green Blue Cyan Magenta Yellow Purple Orange Chartreuse Pink Brown Gold Crimson Violet Crape 232 255 Color Change Macro1 Vector Speed
7. ERTING ORNON INVERTING 1 Pressthe Mode button until it shows d 5 rd 2 Usethe Up Down buttons to set to the desired inversion press enter to confirm TO SET THEDMX CHANNEL CONFIGURATION 1 Pressthe Mode button untilit shows I3CH or SCH 2 Usethe Up Down buttons to set to the desired inversion press enter to confirm TO SET THE MAX I MUM PAN ANGLE 1 Press the Mode button until it showsPRSY or PA36 or PR 8 2 Usethe Up Down buttons to set to the desired inversion press enter to confirm TO SET THEMA XI MUM TILT ANGLE 1 Pressthe Mode button until it shows E ie or t or t g 2 Usethe Up Down buttons to set to the desired inversion press enter to confirm Service Functions TO RESET THEFIXTURE 1 Pressthe Mode button untilthe display shows rtSt 2 Pressenter to confirm your selection TO RESTORE ALL SETTINGS TO THEIR FACTORY DEFAULTS 1 Pressthe mode button until the display reads LoRd 2 Pressenter to confirm your selection 12 er NF E Operation Stand Alone Mode Auto Mode This mode allows a single unitto run to a factory installed program in one oftwo speeds 1 To setthe fixture in auto mode Fast selec RFA once confirmed the display reads FASE 2 To setthe fixture in auto mode Slow selecfiRSL Once confirmed the display reads SLoU Master Slave Mode Master Sound This mode will allow you to link upto 32units together without a controller 1 Use standard DMX cab
8. MINI SPOP WASH MOVING HEAD USER MANUAL NS cal a TERA AN ama Miami om eee TABLE OFCONTENTS ae 1 BEFORE YOU BEGIN U IRR R Rr neunana nnmnnn annann T 3 AC POWER 2 INTRODUCTION U essa sa U FEATUBES usessagssgsusasupuwapiytsssaasinaasaaasasaxasaassayawaesaswascyspasgasqpkuqqyyasquqyapaykuss re 5 DMX CHANNEL SUMMARY 13 CHANNEL MODEFOR SPOT 19 DMX CHANNEL SUMMARY 12 CHANNEL MODE FOR WASH n5 DMX CHANNEL SUMMARY 5CHANNEL MODEFOR O OT e 6 DMX CHANNEL SUMMARY 4 CHANNEL MODE FOR WASH 6 PRODUCT OVER E fV ar eraras ara rarae T eren sn sre e I LLLI 6 3 SETUP ssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssasssssssasssssssssassssnsssssssanasassssssssanannssnassssssnsasnansnsa 7 FUSE REPLACEMENT III Ll 7 FIXTURE LINKING Pa A A A II 7 Data Cabling pe ART RE vit ete s 7 DMX Data Cable m i Cable Connectors 8 3 Pin to 5 Pin Conversion Cha r aana 8 SETTING UP ADMX SERIAL DATA LINK I I I 8 MASTER SLAVE FIXTURE i9 MOUNTING recreate 9 Orientation 9
9. ed DMX Channel Values 4 Channel for Wash CHANNEL VALUE FUNCTION Dimmer Strobe 000 007 Closed 008 134 100 096 3 135 239 Strobe slow fast 240 255 Open Color Macros 000 007 NoFunction 008 021 White 022 034 Red 036 049 Green 050 063 Blue 064 077 Cyan 078 091 Magenta 092 105 Yellow 106 119 Purple 120 133 Orange 4 134 147 Chartreuse 148 161 162 175 176 189 Gold 190 203 Crimson 204 217 Violet 218 231 Crape 232 255 Color Change Macro1 16 5 APPENDIX Technical Specifications WEIGHT amp DIMENSIONS pire bce dicey cpl 6 8in 173 mm ME Rd 6 8 in 173 mm eue Oeo PE rs Mec EEE 9 8 in 249 mm uu cro cU E ERU oue 8 3 Ibs 3 8 kg POWER Switch selectable power settings 120V 60Hz AC or 230V 50Hz SU eae uu LL 2A250V Power Consumption 68 1W 0 60A Maxat 120V Inrush Power 83 6W 1 41A inrush at 120V Power Factor coo EE M Ce E rr MM S Sas 0 92 LIGHT SOURCE PHOTO OPTIC Beam Angle ce ue s S Illuminance at 1M RANGE MERE ambient temperie Ec PRAEC I o cm EEUU TET 104 F 40 C CONTROL amp PROGRAMMING Datanpa in TO NN locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin wass a
10. l LED Display shows the menu items you select from the menu map on page 11 When a menu functionis selected the display will show immediately the first available option forthe selected menu function To selecta menuitem press ENTER Press the lt MODE ESC gt button repeatedly until you reach the desired menu function Use the UP and DOWN buttons to navigate the menu options Press the ENTER button to select the menu function currently displayed orto enable a menu option To return to the previous option or menu without changing the value press the lt MODE ESC gt button 10 Use the lt MODE ESC gt Use the UP DOWN button to scroll through and ENTER buttons to these menu items scroll through these menu items When navigating the menu Use the UP button to move up Use the DOWN button to move down Use the ENTER button to moveright Use the MODE buton to move left or to scroll through the left most items in the menu map 11 User Configurations TO SET THE PAN TO INVERTING OR NON INVERTING 1 Pressthe Mode button until it shows PHa or rPRa 2 Usethe Up Down buttons to set to the desired inversion press enter to confirm TO SET THE TILT TO INVERTING OR NON INVERTING 1 Press the Mode button until it shows t iL or rt iL 2 Usethe Up Down buttons to set to the desired inversion press enter to confirm TO SET THELED READOUT TO INV
11. les to daisy chain your units together via the DMX connector on the rear of the units Proper performance it may be necessary to use a terminator atthe lastfixture For more information about terminators see page 8 2 Choosea unitto function as the Master Select NAFA NASL orNStS see below for readout depending upon which master mode you require The master unit must be the firstunit in line Finally chain the units togetherusing DMX cable Master Auto NAFA or NASL Master Sound NSS becomes SrUn when confirmed 3 Select slave function by using the Up Down keys to reach SLAvin the Master Auto menu on the slave units and they will reactin the same as the Master Slave 98 becomes Son when confirmed DMX Mode This mode allows the unit to be controlled by any universal DMX controller If youare unfamiliar with DMX please read the DMX Primeron page 19 1 The default mode for the fixture is DMX which appears as 400 l on the LED Readout 13 DMX Channel Values 13 Channel CHANNEL VALUE FUNCTION 2 000 255 Fine 3 000 255 Tilt 4 000 255 Tilt Fine 5 000 255 Vector Speed Normal Slow Dimmer Strobe 000 007 Closed 008 134 100 0 6 135 239 Strobe slow fast 240 255 Open Red 7 000 255 0 100 Green 0 100 Blue 0 100 Color Macros 000 007 NoFunction 008 021 White 022 034 Red 036 049 Green 050 063 Blue 064 077 Cyan 078 091 Magenta 0
12. llowing characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductorand shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms CAB LEC ONN ECTORS Cabling musthave a male XLR connector one end and a female XLR connector on the other end DMX connector configuration 3 COMMON 9 Z e y oe Teman Terminationreduces signal errors To avoid signal transmissionproblems andinterference itis always advisable to connecta DMX signal terminator Resistance 120 ohm 1 4w between pin 2 DMX and pin DMX of the last fixture INPUT CAUTION Do notallow contact betweenthe common andthe fixture s chassis ground Grounding the common can cause aground loop and your fixture may perform erratically Test cables withan ohm meterto verify correct polarityand to make sure the pinsare not groundedor shorted tothe shield oreach other 3 PIN TO 5 PIN CON VERSION CHART Note If youuse a controllerwith a 5pin DMX outputconnector youwill need touse a 5pin to 3pin adapter CHAUVET Model No DMX5M orDMX5F The chart below details aproper cable conversion 3 PIN TO 5PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do notuse Do notuse Do notuse Do notuse
13. lso require aslave setting Please consultthe ANI amet amt Operating Instructions section in this manual forcomplete instructions for this typeof setup and configuration E Mounting ORIENTATION This fixture may be mounted in any position provided there isadequate room forventilation RIGGING It isimportant neverto obstructthe fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjustthe angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs Hanging Clamp When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables must always be used Never mountin places where the fixture will be exposedto rain high humidity extreme temperature changes orrestricted ventilation Note Clamp is soldseparately 4 OPERATING INSTRUCTIONS Navigating the Control Panel Access control panelfunctions using the four panel buttons located directly underneath the LCD Display Button Function lt MODE ESC gt lt UP gt lt DOWN gt lt ENTER gt Used to access the menu or to return toa previous menu option Scrolls through menu options in ascending order Scrolls through menu options in descending order MODE ESC UP DOWN Used to select and store the current menu or option within a menu O ENTER The Control Pane
14. ss sa pin 1 shield pin 2 pin 3 Protocols sm uz DMX 512USITT ORDERING INFORMATION Mini SpOUWaSHE weenie nee S Qs Optional Controller WARRANTY INFORMATION Warranty 17
15. t while operating The unitmust be installed ina location with adequate ventilation atleast 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size and type e Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture attemperatures higher than this In the event ofa serious operating problem stop usingthe unit immediately Never try to repairthe unit by yourself Repairs carried outby unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Don t connectthe device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnectthe power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on 2 INTRODUCTION Features CONTROL FEATURES 5or13 channel DMX 512LED moving yoke Pan 5400 tilt 2700 RGB color mixing Gobo wheel 9 gobos open Gobo wheel spin effect 9 Variable electronic strobe Variable electronic dimmer 0 100 Vector speed channel for pan tilt RGB color mixing and color macros Built in movement macros via master slave
16. th exact same type fuse Insert the fuse holder back in compartment its place and reconnect power Remove using aflat head screwdriver The fuse islocated inside this Fixture Linking You will need aserial data link to run light shows of one or more fixtures using a DMX 512 controller or torun synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures ona serial data link determines the number of fixtures the data link can support Important Fixtureson a serialdata link mustbe daisy chainedin one single line To comply withthe EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on serial datalink without the use of aDMX optically isolated splittermay result in deterioration ofthe digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures ona serial data link 32 fixtures Data Cabling To link fixtures together you must obtain data cables If you choose create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX DATA CABLE Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannottransmit DMX data reliably over long distances Thecable will have the fo