Home
User manual - Sams elektronik doo
Contents
1. MSG Sams elektronik d 0 0 Sams sams rs e www sams rs 5 sadaf mS Signal generators UNPACKING AND INSTALLATION The box contains Module Back connector optional Protective pad for SRU rack frame optional M2 5x6 7985 screw optional SRU rack frame optional Power corde for SRU rack frame optional User manual optional Before use check the contents of the box For any deficiency report to the seller or the manufacturer of the product DEVICE IS INSULATED BY PROTECTIVE WRAP AND PACKED IN A CARDBOARD BOX DEVICE IS SENSITIVE TO SHAKES AND DROPS HANDLE WITH CARE DURING TRANSPORT AND ASSEMBLY Check if the product is damaged during transport PROCEDURES FOR SAFE USE OF THE DEVICE il Places for fastening MAINTENANCE The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of If the device is not supplied with SRU rack frame remove the protective wrap from the device If the device is supplied with SRU rack frame remove the protective wrap from the chassis For devices that are AC 230V 50Hz powered the device is supplied with power cord Use only power corde that comes with the device SRU rack frame is mounted in a 19 special purpose rack cabinets designed for this type of device Screw device with four screws Screws for fastening a
2. ENGLISH sd mS m Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs Copyright 1999 2014 Sams elektronik d o o Published 23 february 2009 Updated 25 november 2014 210 3 edition 1 Code 006 111 006 107 MSG BB6 s Reference generator for SRU rack frame standalone USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage sda mS Signal generators elektronik a WARRANTY Dear User Thank you very much for purchasing our product Your purchase is a wise investment The equipment you have purchased is manufactured with great care from high quality parts and materials It is designed to fully meet the needs according to specifications if properly installed used and maintained according to the enclosed instructions Any technical failure or deficiency that occurs during the warranty period specified on the invoice of the purchased equipment will be inspected and serviced by Sams elektronik doo or an authorized service center of the manufacturer with the conditions set out in the warranty statement THIS DEVICE IS INTENDED FOR PROFESSIONAL USE WARRANTY STATEMENT 1 Product has declared characteristics Within the warranty period manufacturer ensures the removal of technical failures product defects or replacement of products if declar
3. WER PANEL 12 Sams elektronik d o 0 e sams sams rs e www sams rs MSG SGT elektronik Signal generators INSTALLATION STANDALONE Connect the power cord The device works only on AC 230 V 50 Hz O Rear side e 9909900909 Connect all necessary connectors oA Turn on the device before the unit is turned on GT om SYSTEM CLOCK Black burst generator ANALOG 6x P Z MSG BB6s f_wwwsamsts Front side If everything is OK the LED will flash yellow MSG Sams elektronik d o 0 Sams sams rs e www sams rs 13 sda mS Signal generators elektronik i NOTES 14 Sams elektronik d 0 0 e sams sams rs e www sams rs MSG
4. ace for power supply module MSG Sams elektronik d 0 0 e sams sams rs e www sams rs 9 SGT 1 Signal generators elektronik eE SSS aa 1 The module set between the guides not metal plate 2 Locking lever mount behind the groove 3 Push the lever to lock in an upright position The module is locked 10 Sams elektronik d o 0 e sams sams rs e www sams rs MSG SGT 1 elektronik BACK CONNECTORS lt Fix the back connector with M2 5 screw MSG BB6 O L lt BR OUT 1 ae G d BR OUT 2 CR BR OUT 3 lt 4 BR OUT 4 lt 4 BR OUT 5 lt BB OUT 6 SAMS Electronics www sams co yu lt q Fix the back connector with M2 5 screw MSG BB6 Be sure to install a protective pad before installing the back connectors C LC o o g o o A 4 A p 0 g A og A o A A o og A g O Signal generators MSG Sams elektronik d 0 0 e Sams sams rs e www sams rs 11 SGT 1 elektronik Signal generators Place the back connector Fix the back connector with M2 5 screw SRU REAR SIDE Rear side view 1 Mass 2 Power switch 3 The socket 4 Connections for back connectors DANGER DO NOT INSERT SHARP METAL OBJECTS OR FINGERS INTO THE SPACE BEHIND THE POWER PANEL HIGH VOLTAGE 442 THE SIGN LIGHTNING IN A TRIANGLE IS TO ALERT THE USER TO THE PRESENCE OF LIFE THREATENING HIGH POWER LABEL IS PLACED NEXT TO PO
5. e from not following the user manual instructions improper installation comes to mechanical damage during use repairs and modifications by unauthorized persons installation of non genuine spare parts and if the buyer does not comply with all warnings listed in the user manual 3 The warranty is voided if the device is damaged during the disturbances from the environment natural disasters floods hail etc suffered an electric shock or lightning strike IMPORTANT NOTES 1 Be sure to thoroughly read the user manual If you have any doubts about the instructions contact the technical support of the manufacturer 2 Before contacting for technical help please make sure that are provided with all necessary conditions for normal operation 3 If the malfunction or defect in the device does not eliminate within a reasonable time from the date of failure the warranty period shall be extended for as many days as the unit is in service 4 Eor all maintenance interventions shall solely be authorized services listed in this Warranty Certificate 2 Sams elektronik d o 0 s Sams sams rs e www sams rs MSG sda mS elektronik Signal generators SAFETY WARNINGS FOR SRU RACK FRAME UPOZORENJE IMPORTANT SAFEY PRS 4 WARNING DOK S NR ONOM eg CAUTION r TO AVOID RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THE UNIT TO MOISTURE OR RAIN EEE DON AOE HAZARD The symbol lightning in a triangle is to alert the user to the presence of hig
6. ed characteristics of the product are changed 2 Ifthe goods are not delivered as specified with the contract the consumer has the right to request from the manufacturer service provider to eliminate the lack of conformity without charge repair or replacement or to request an appropriate price reduction or terminate the contract 3 Any repair or replacement must be made within a reasonable time without significant inconvenience to the consumer taking into account the nature and the purpose for which the consumer has purchased the product 4 The consumer has the right to terminate the contract if he can realize the right to repair or replacement or if the manufacturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of servicing the product is 6 years from the launch on the market The product purchased outside the territory of Serbia does not fall under the terms of this warranty only to 1 year factory warranty from date of purchase TERMS OF WARRANTY 1 The warranty period begins on the date of sale referred in the invoice 2 The buyer loses the right to warranty if the defect cause failur
7. erson authorized by the manufacturer must check the device after completion of service 24 Allow a free rack unit 1RU above and below the device for ventilation or put rack fan under the device TECHNICAL SUPPORT AND SERVICE Sams elektronik has made every effort to ensure that the equipment works in perfect condition In the event that problems that occur can not be resolved or if you have any questions regarding this equipment or information about other products produced from Sams elektronik contact your local sales representative or call Sams elektronik directly through one of the ways listed below Sales 381 11 3806 254 Technical support 381 11 2402 212 Service 381 11 4056 051 Email Sales sasa sams rs Technical support and service sams sams rs Web site www sams rs Address SAMS ELEKTRONIK d o o 48 Zivka Davidovica st 11050 Belgrade Serbia 4 Sams elektronik d o 0 s Sams sams rs e www sams rs MSG sda mS elektronik Signal generators TABLE OF CONTENTS Description Page UNPACKING AND INSTALLATION csniiseeanea a 6 MAEN TENANC E o uirri arc TEES EEEE EEEE 6 REMOVAL AND STORAGE HT 6 DE CRIP TION G EZ E E EEE A E E e R 7 MODULE INSTALATION IN SRU RACK FRAMES cccceccceseeeseeteeeestaeataeaeaeasasaeesseeeeeesesenees 9 DACKE CONNECTOR TET 11 ORU REAR DE arere eeri E E E E EE O 12 INS TALEATION S TANDALONE reio EEEE 13 NOTES e E EEE ee au ccansuseecses enotstaueusaerensyaneuneendeqnieueeueaeaes 14
8. es Specifications and designs are subject to change without notice BACK CONNECTOR ADCV 8 MSG BB6 o 6 O 6 O 6 o G o 6 o 6 o A O g Gr U 6 G G O 6 O G on og G G o 6 G G o A SAMS Electronics www sams co yu Sams elektronik d 0 0 e Sams sams rs e www sams rs SGT Signal generators elektronik MSG BB6s Black burst generator Broadcast quality 6 black burst outputs CCIR 624 4 PAL standards High stability Internal precision master clock 1ppm External reference genlock mode optional MSG BB6 is generator black with 6 outputs Outputs are generated from the same source in order to ensure synchronization without delay This module is perfect as the main video reference which has an internal precision temperature and voltage stable master clock 1ppm Signal is derived from the temperature stable oscillators This device provides a stable output signal and does not need to be adjusted during operation in different temperature environments MSG BB6 video outputs are the CCIR 624 4 standard front side L a 7 S 7 S l R 6 9900090900 amp rear side TECH NICAL SPECI FICATIONS Specifications and designs are subject to change without notice GENERAL INFORMATION SIDI eran ede es ARE EAE A EE EE A 006 107 PWEDE rere iaae a a A E a EEA E AE A 1 5 Kg TYDE eaii a aa aaaea a aaeoa 1RU rack frame Dimensions css ee eee ee eee eee 1RU
9. h voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device CLASS I DEVICE Grounding is connected to the chassis of the device The power supply is protected with fuse against overload A DECLARATION OF CONFORMITY for product SRU RACK FRAME WITH POWER SUPPLY PSU 212 WITH CORRESPONDING MODULES AND BACK CONNECTORS The product is designed and manufactured according to the following regulations Electromagnetic Compatibility Directive EMC Low Voltage Directive ELV Documentation confirming statements can be obtained on written request for review MSG Sams elektronik d o 0 Sams sams rs e www sams rs 3 sda mS Signal generators elektronik AEE EE WARNING TO AVOID ELECTRIC SHOCK DO NOT OPEN COVER DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER 1 Read all safety and operating instructions before using the device 2 Keep all safety and operating instructions 3 Follow the instructions from the user manual 4 Do not upgrade device except in the case advised by the manufacturer 5 Do not use the device in the presence of water and or moisture 6 Do not pour water or moisten the device with any type of liquid 7 Openings on device are provided for ventilation 8 Do not block air flow through the ventilatio
10. l precision temperature and voltage stable master clock 1ppm Signal is derived from the temperature stable oscillators This device provides a stable output signal and does not need to be adjusted during operation in different temperature environments MSG BB6 video outputs are the CCIR 624 4 standard This module is designed for Sams SRU 306 3RU rack frame but can be delivered as stand alone 1RU device TECHNICAL SPECIFICATIONS OPSTE INFORMACIJE esa sissa agaaa a EE Ea EEEE EEE 006 111 ANEIDES E E 0 4 Kg E a E E N E N EN A module lt DIMENSIONS riesciti anina anaa aaaea e aa ii 100 x 160mm Required sss sees eee SRU rack frame back panel ADCV 8 Delivery Indudes ss sss sese eee eee device user manual ANALOG OUTPUT IS s T 6 BNC female DUIS ereiaro ienna ea a Ea Ea CCIR 624 4 PAL s Black BUSU TTT 0 300V p p A SVNC saad duohiadadenerasinteanniineietandineieraitiira mah EE U Daai akai 0 300V p p MASTER OSCILATOR lt FreqUENCYi variieren adena a aAA E 27 000000MHz VCTCXO eel lel 1PPM 25 C Stability versus temperature sese ee eee e ee eee ee e 1PPM 0 55 C Stability versus TIMES esse eee eee ee eee eee eee 1PPM Year max POWER BMS E E E E A E 2 x 12V AC G EN E E E E E 8W TEMPERATURE Performance sees ee eee ee eee eee 5 40 C aleis Tus T 0 50 C ORDERING INFORMATION Code Name Description 006 111 MSG BB6 Black burst generator 001 509 ADCV 8 Back connector 001 605 SRU 306 Rack frame for 6 modul
11. n openings 9 This product is powered by AC 230V 10 50Hz 10 This product is equipped with a three wire cord with grounding 11 This device is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and warranty void 15 Do not use the device in an environment that contains flammable or explosive materials in any physical state 16 Turn off the power corde before cleaning Do not use liquid aerosol or flammable cleaners Use only a dry cloth 17 Servicing is performed by a qualified person Removing the cover user is exposed to high voltages 18 Never use the device when the cover is open and the device is powered on 19 Do not expose to extreme high or low temperatures 20 Do not expose to sudden temperature changes 21 Call service in the following cases The power cord or plug is damaged Liquid or foreign objects is inside the device The machine is exposed to water and moisture The device does not function according to specification The unit has been dropped or damaged The characteristics are significantly changed 22 Use only specified replacement parts 23 Professional p
12. re not supplied with the device The device must be connected to ground A device that is not connected to the grounding does not function properly according to factory declarations and can cause adverse effects on users and other equipment Strictly comply to all steps for proper connection of devices in the system On the SRU rack frame are 3 types of mass CHASSIS MAINS and OV The factory all three are connected According to the user s needs the masses can be switched over between them injury REMOVAL AND STORAGE 1 Before dismantling the device switch off the power remove the power cord and remove all other connectors 2 Remove the four screws for fastening 3 Remove the device from rack cabinet 4 Wrap the machine in the foil to protect it from dust Package it in a box 5 The device must be stored in a room without moisture Illustration mounted device elektronik Sams elektronik d 0 0 s Sams sams rs e www sams rs MSG SGT MSG elektronik DESCRIPTION Signal generators MSG BB6 Black burst generator Broadcast quality 6 black burst outputs CCIR 624 4 PAL standards High stability Internal precision master clock 1ppm External reference genlock mode optional MSG BB6 is generator black with 6 outputs Outputs are generated from the same source in order to ensure synchronization without delay This module is perfect as the main video reference which has an interna
13. x 19 x 150mm Delivery includes cc sccssseees device power corde user manual ANALOG OUTPUT S CTE ala TT 6 BNC female ers sl HHT CCIR 624 4 PAL Black BUSU wc euanet aecetn dave nntrenssmaponenercemauueduoceeeusenencatoned 0 300V p p SVN aaa ia a AA A EA A A E EE EEE 0 300V p p MASTER OSCILATOR gl Le dooiers ea EE ETE 27 000000MHz VCTCXO eei Le 1PPM 25 C Stability versus temperature sees ee eee ee ee ee 1PPM 0 55 C Stability versus tiMe sss sees eee eee eee ee eee 1PPM Year max POWER ele le LT 230V AC 10 d Sasu 30W Freg UENCY i eiin tehpaneneyaedanetseaoandanstnenieacded arduncanbenesauetdatounee 50Hz Overload protection sese eee eee front Mounted Circuit Breaker TEMPERATURE Performance T 5 40 C Operati HT 0 50 C ORDERING INFORMATION Code Name Description 006 107 MSG BB6s Black burst generator 8 Sams elektronik d 0 0 e sams sams rs e www sams rs MSG SGT 1 elektronik Signal generators MODULE INSTALATION IN SRU RACK FRAMES On the front side of rack frame unscrew the screws Open the door Make sure that the module is set to the correct place in relation to the back connector BEFORE INSTALLING OR REMOVING THE MODULE FROM SRU ALWAYS TURN OFF THE POWER Lock module with lever to the position NOTE NEVER PLACE MODULE TO PLACE OF THE POWER SUPPLY MODULE WARNING FOR POWER SUPPLY ONLY The label that indicates the pl