Home

1220 Infinity LC Site Preparation Checklist

image

Contents

1. G4288B C 0 55 C 32 131 F constant temperature lt 95 non condensing G4290B C 0 55 C 32 131 F constant temperature lt 95 non condensing G4294B 0 55 C 32 131 F constant temperature lt 95 non condensing oft Agilent Technologies 1220 Infinity LC Site Preparation Checklist Power Consumption Special Notes 1 If a computer system is supplied with your instrument be sure to account for those electrical outlets 2 The heat dissipation can be calculated from the the active power using the following equation 1 W 3 413 BTU h G4286B 100 240 V 10 50 60 Hz 5 240 VA 210 W G4288B C 100 240 V 10 50 60 Hz 5 240 VA 210 W G4290B C 100 240 V 10 50 60 Hz 5 240 VA 210 W G4294B 100 240 V 10 50 60 Hz 5 240 VA 210 W Issued 15 Jun 2015 Revision 1 4 Copyright 2015 Agilent Technologies Page 4 of 5 oe Agilent Technologies 1220 Infinity LC Site Preparation Checklist Required Operating Supplies by Customer N LABORATORY 4 Special Notes e For information on Agilent consumables accessories and laboratory operating supplies please visit http www chem agilent com en US Products consumables Pages default aspx HPLC Grade Water needed for installation 500 mL Vials needed for installation 5x 1 8 mL Aceton or suitable solvent for UV tracer checkout 1 mL Other Special Requirements S
2. oft Agilent Technologies Thank you for purchasing an Agilent instrument To get you started and to assure a successful and timely installation please refer to this specification or set of requirements Correct site preparation is the key first step in ensuring that your instruments and software systems operate reliably over an extended lifetime This document is an information guide AND checklist prepared for you that outlines the supplies consumables space and utility requirements for your equipment for your site For additional information about our solutions please visit our web site at http www chem agilent com en US Pages HomePage aspx Customer Responsibilities Make sure your site meets the following prior to the installation date using the checklist below For details see specific sections within this document including The necessary laboratory or bench space is available The environmental conditions for the lab as well as laboratory gases tubing The power requirements related to the product e g number amp location of electrical outlets The required operating supplies necessary for the product and installation Please consult Other Special Requirements section below for other product specific information If Agilent is delivering installation and familiarization services users of the instrument should be present throughout these services otherwise they will miss important operational maintenance and safety informati
3. on Important Customer Information 1 If you have questions or problems in providing anything described as Customer Responsibilities above please contact your local Agilent or partner support service organization for assistance prior to delivery In addition Agilent and or its partners reserve the right to reschedule the installation dependent upon the readiness of your laboratory 2 Should your site not be ready for whatever reasons please contact Agilent as soon as possible to re arrange any services that have been purchased 3 Other optional services such as additional training operational qualification OQ and consultation for user specific applications may also be provided at the time of installation when ordered with the system but should be contracted separately oft Agilent Technologies Dimensions and Weight Identify the laboratory bench space before your system arrives based on the table below Pay special attention to the total height and total weight requirements for all system components you have ordered and avoid bench space with overhanging shelves Also pay special attention to the total weight of the modules you have ordered to ensure your laboratory bench can support this weight Special Notes 1 The instrument requires a space of at least 2 5 cm 1 0 inch on both sides and approximately 8 cm 3 1 inches at the rear for the circulation of air and room for electrical connections Oooo e me e
4. p P h emee oft Agilent Technologies Environmental Conditions Operating your instrument within the recommended temperature ranges insures optimum instrument performance and lifetime Special Notes 1 Performance can be affected by sources of heat amp cold e g direct sunlight heating cooling from air conditioning outlets drafts and or vibrations 2 The site s ambient temperature conditions must be stable for optimum performance of the system as specified in the Performance Specifications section of the User Manual Temperature changes of 2 C h or less as defined by ASTM conditions are required to achieve best possible baseline stability Higher variations will definitely result in higher signal drift and wander of the baseline 3 Do not store ship or use your 1220 Infinity LC under conditions where temperature fluctuations could cause condensation within the instrument Condensation will damage the system electronics If your 1220 Infinity LC was shipped in cold weather leave it in and allow it to warm up slowly to room temperature to avoid condensation 4 Better drift performance depends on better control of the temperature fluctuations To realize the highest performance minimize the frequency and the amplitude of the temperature changes to below 1 C h 1 8 F h Turbulences around one minute or less can be ignored G4286B 0 55 C 32 131 F constant temperature lt 95 non condensing
5. pecial requirements for the G4292A 1220 Mobile Upgrade kit necessary as specified in the G4292A 1220 Mobile Upgrade Kit Site Preparation Checklist Issued 15 Jun 2015 Revision 1 4 Copyright 2015 Agilent Technologies Page 5 of 5