Home
10/100BaseTX to 100BaseFX Industrial Media Converter User Manual
Contents
1. 10 100BaseTX to 100 Industrial Media Converter User Manual dazeon AAXEON TECHNOLOGIES Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content
2. FG CVV nem GCE Mark i Ga m 1 ne LL S 1 scum me 3 PACKING EIS E 4 eric 4 Hardware 5 FTODD Panels n 5 TO er EE 6 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 7 LED Inaieatofgsi used DIP OWC aa a a a 8 PONS ues TM iz EUM i 9 GAD ING MEHR NET MER 11 Mounting Installation s 12 DIN Rail Mounting 12 Wall Mount Plate Mounting 14 Network 15 Installation 1 15 Troubles shooting sseeesssss 17 Technical Specification 18 Overview Introduction The Industrial 10 100Base TX to 100BaseFX Media Converter is a cost effective solution for the converting between 10 100Base TX and 100Base FX cabling it allows you to extend the cabling distance of your 100Base FX network up to 2 kilometers for multi mode fiber or 30 kilometers for single mode fiber The Fast Fiber Converter module gives you the option to choose from the most popular fiber cabli
3. problem with power cord Than check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance Ifthe LED indicators are normal and the connected cables are correct and the packets still cannot transmit Please check your system s Ethernet devices configuration or status Technical Specification Communications Compatibility LAN Transmission Distance Transmission Speed Interface Connectors LED Indicators Power Power Consumption Power Input Fault Output The technical specifications of the unit are listed as follows IEEE 802 3 802 3u 802 3x 10 100Base TX Multi Mode Fiber 2km Single Mode Fiber 30km Up to 100 Mbps Fiber SC multi mode amp single mode 1 x RJ 45 6 pin removable screw terminal power amp relay Unit P1 P2 Fault Ethernet port 10 100M Link Active Fiber HDX FDX LNK ACT 2 74 W 2 x Unregulated 12 48 Vpc 1 Relay Output The power supply should meet the document listed by UL and its output must comply with L P S Mechanism Dimensions WxHxD Enclosure Mounting Protection ESD Ethernet Surge EFT for power Power Reverse Environment Operating Temperature Operating Humidity Storage Temperature Certifications Safety EMI 30 x 95 x 140 mm IP30 Metal shell with solid mounting kits DIN35 rail Wall 6 000 Vpc 3 000 Vpc Yes 40 75 C wide op
4. reverse steps above Network Connection In this paragraph we will describe how to install the Industrial 10 100Base TX to 100BaseFX Media Converter x GG Single Mode Fiber Up to 30 Km uct 100M LNK ACT 100M LNK ACT oc UTP UTP 10 100Mbps Port 10 100Mbps Port RJ 45 Connector RJ 45 Connector of Switch or end Station of Switch or end Station Industrial10 100BaseTX to 100BaseFX Media Converter Connect diagram Installation Steps 1 Unpack the unit packing 2 Check the DIN Rail is screwed on the unit If the DIN Rail is not screwed on the unit Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the unit then please refer to Wall Mount Plate Mounting section for wall mount plate installation 15 To hang the unit on the DIN Rail track wall please refer to the Mounting Installation section Power on the Unit How to wire the power please refer to the Wiring the Power Inputs section The power LED on the unit will light up Please refer to the LED Indicators section for meaning of LED lights Prepare the twisted pair straight through Category 5 cable for Ethernet connection Insert one side of Category 5 cables into the Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch PC or Server The UTP port RJ 45 LED on the u
5. 100BaseFX Media Converter each of them has its own specific meaning as below table LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 has failed Fault Red n Power input 1 and 2 are both functional or no power inputs 7 Full duplex mode FDX COL Yellow Flashing Packet collision occurred fiber port Off Half duplex mode On Connected to network LNK ACT Green Flashing Networking is active fiber port Off Not connected to network On Link to 100Mbps network 100M RJ 45 Yellow Off Link to 10Mbps network On Connected to network LNK ACT Green Flashing Networking is active RJ 45 Off Not connected to network DIP Switch The DIP Switch is used to configure operation mode for LFP Link Fault Pass Through and operation mode for UTP Fiber port The default value of DIP switch is OFF S W No Status Description ON Enables Port Power Alarm OFF Disable Port Power Alarm ON Enables LFP Disables 100Base FX Half mode E OFF 100Base FX Full mode ON Media mode 100TX to 100FX OFF Switching mode Link Fault Pass Through DIP Switch 2 When LFP enabled it allows UTP link failures to be reported to the fiber side and also allows Fiber link failures to be repo
6. 60 C standard model With such a wide range you can use the Industrial 10 100Base TX to 100BaseFX Media Converter in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quick and easy The 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and Fault help you diagnose immediately Features Provides 1 x 10 100Mbps Ethernet ports with RJ 45 connector Provides 1 x SC multi mode amp single mode fiber connector Supports full half duplex flow control Supports MDI MDI X auto crossover Supports surge EFT protection 3 000 Voc for power line Supports 6 000 Vpc Ethernet ESD protection Supports auto negotiation Supports store amp forward transmission Supports redundant 12 48 Vpc power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperatures from 40 75 C wide operating temperature model or 10 60 C standard model Packing List 1 x Industrial 10 100BaseTX to 100BaseFX Media Converter 1 x User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input Hardware Description In this chapter you will be given an overview of the Industrial 10 100Base TX to 100BaseFX Media
7. Converter hardware installation procedures Front Panel The Front Panel of the Industrial 10 100Base TX to 100BaseFX Media Converter is shown as follows 100Base Fiber Port LED Indicator DIP Switch 100Base RJ 45 Port Front Panel of the Industrial 10 100TX to 100FX Media Converter Top View The top panel of the Industrial 10 100Base TX to 100BaseFX Media Converter is equipped one terminal block connector of two DC power inputs Top Panel of the Industrial 10 100Base TX to 100BaseFX Media Converter Wiring the Power Inputs Please follow the steps below to insert the power wire V V V V Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status including power failure port link failure and form an open circuit Insert the wires into the fault alarm contact Note The wire gauge for the terminal block should be in the range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm LED Indicators There are few LEDs which display the power status and network status located on the front panel of the Industrial 10 100Base TX to
8. d 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data minus TD Receive Data minus RD 3 Transmit Data plus TD Receive Data plus RD Switch Router or PC 3 TD 3 RD 6 TD 6 RD RD 1 2 RD 4 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 6 TD 6 TD RD RD 2 RD 2 RD Cross Over Cable Schematic Fiber Port The fiber port of SC type connector can work in multi mode 2Km or single mode 30Km When you connect the fiber port to another one please follow the figure below to connect accordingly Wrong connection will cause the port cannot work normally SC Connector Tx Tx Rx Rx Cable Wiring SC to SC RAS AR TX B Rx ATTENTION ATTENTION This is a Class 1 Laser LED product Don t stare into N ihe Laser ED Beam Cabling Twisted pair segment can be connected with unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner converter switch hub
9. erating temperature model 10 60 C standard model 596 9596 non condensing 40 85 C UL cUL CE EN60950 1 FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 19 EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 20
10. ng connectors SC multi mode and single mode connector Fast Fiber Converters Module The Industrial 10 100Base TX to 100BaseFX Media Converter provides you with one Fiber connector for your fiber optic cable and one Ethernet RJ 45 port Auto MDI MDIX for your 100Base TX copper cable connection There are four DIP switches to set the operation mode for UTP Fiber ports and link loss forwarding function Dual Power Input To reduce the risk of power failure the Industrial 10 100Base TX to 100BaseFX Media Converter provides 12 48 Vpc dual power inputs If there is power failure Industrial 10 100Base TX to 100BaseFX Media Converter will automatically switch to the secondary power input Flexible Mounting Industrial 10 100Base TX to 100BaseFX Media Converter is extremely compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Advanced Protection The power line of Industrial 10 100Base TX to 100BaseFX Media Converter supports up to 3 000 Vpc EFT protection which secure equipment against unregulated voltage and make systems safer and more reliable Meanwhile 6 000 Vpc ESD protections for Ethernet ports 1 make Industrial 10 100Base TX to 100BaseFX Media Converter more suitable for harsh environments Wide Operating Temperature The operating temperature of the Industrial 10 100Base TX to 100BaseFX Media Converter is between 40 75 C wide operating temperature model or 10
11. nit will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning Connect one end of the fiber cable to the SC single mode connector on this converter and the other end of the fiber cable to the SC single mode connector on the other 100 Base FX device Note Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 cable When all connections are all set and LED lights all show in normal the installation is complete Troubles shooting m Verify that you are using the right power cord adapter DC 12 48V please don t use the power adapter with DC output bigger than 48V or it will burn this converter down Select the proper UTP STP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 4 or 5 cables for 10Mbps connections or 1000 Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet B Diagnosing LED Indicators the unit be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions F the power indicator does not light on when the power cord is plugged in you may have a
12. rted to the UTP side Therefore a link fault pass through feature is provided in both UTP and Fiber side Media mode DIP Switch 4 When media mode is enabled it operates with the minimum latency The transmission flow does not wait until entire frame is ready but instead it forwards the received data immediately after the data being received And TP port should be forced 8 at 100M in this application When DIP Switch is in switching mode OFF the converter function is the same as a Switch Hub Note Please don t change the DIP switch setting when UTP or fiber port is transmitting or receiving data It may cause some data error Besides if you change the DIP switch setting please power off the converter and power on again to make the setting effective Ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T or 100Base TX devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures as below for straight through and crossover cable schematic B RJ 45 Pin Assignments Note and signs represent the polarity of the wires that make up each wire pair All ports on this unit support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 an
13. workstation etc must be less than 100 meters 328 ft long Fiber segment using single mode connector type must use 9 125um single mode fiber cable User can connect two devices in the distance up to 30 Kilometers W Fiber segment using multi mode connector type must use 50 62 5 125 um multi mode fiber cable User can connect two devices up to 2Km distances Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the unit when out of factory If the DIN Rail is not screwed on the unit please see the pictures and follow the steps below to screw the DIN Rail on the unit Rear Side DIN Rail 1 Usethe screws to screw the DIN Rail on the rear side of the unit 2 Toremove the DIN Rail reverse the step 1 3 After the DIN Rail is screwed on the rear side of the unit insert the top of DIN Rail into the track 4 Then lightly push the DIN Rail into the track 5 Check if the DIN Rail is tightened on the track or not 6 remove the unit from the track reverse steps above Wall Mount Plate Mounting Follow the steps below to mount the unit with wall mount plate 1 Remove the DIN Rail from the unit loose the screws to remove the DIN Rail Place the wall mount plate on the top amp bottom side of the unit Use the screws to screw the wall mount plate on the unit Use the hook holes at the corners of the wall mount plate to hang the unit on the wall To remove the wall mount plate
Download Pdf Manuals