1. CONTROL UNIT OMEGA 804 User manual User manual OMEGA 804 Series INDEX 1 DESCRIPTION AND MAIN 3 2 DISPLAY AND CONTROL BUTTONS un 3 INSTALLATION AND non ener nnne nnn 4 4 MENU STRUC TURE ists sce nnn 5 5 HOW TO CHECK OR MODIFY PARAMETERS eere 5 INITIAL CONFIGURATION cuit seras a pagekS ee 6 7 TYPES OF CONFIGURATION DEPENDING ON THE APPLICATION 6 1 SYSTEM USED AS A ROPE TENSION MONITOR WRHT eese 7 7 2 SYSTEM USED AS A LOAD WEIGHING DEVICE 0 8 8 ADDITIONAL FUNG TIONS ea 10 Gle MOLD RINGO IN rcm 10 9 2 SGHAIN GOMPENSALION Zee De sera 10 9 ERROR CODES AND TROUBLESHOOTING eene 11 10 gue 11 11 QUICK CONFIGURATION GUIDE a 12 User manual OMEGA 804 Series 1 DESCRIPTION AND MAIN FEATURES Dinacell OMEGA 804 is a control unit to measure monitor and limit the load of a elevator besides to monitor the tension of each elevator rope individually This system consists of inputs for up to eight sensors and the following inputs and outputs to interface with the elevator controller output for display in the cabin four relay contacts to inform of the load levels chosen and one in
2. a load weighing device LWD The PEF operation sets the zero when sensors are not installed on the ropes After this the ropes tension can be measured and adjusted individually IREF operation is not available for TCA sensor User manual OMEGA 804 Series 7 1 SYSTEM USED AS A ROPE TENSION MONITOR WRT Make sure that the sensors installed on the ropes IPEF p 1 ress 1 Set o with the un value ALL to enter value to save IPEE en Display shows this Now install sensors on the ropes Make sure the cabin is empty and there s no weight in the car roof Press Press Choose countdown to enter seconds 2 Adjust ZERO with e e A the cabin empty Display Choose Change shows this digit digit Wait countdown Press x2 to start Press 3 sec to exit menu Press 2 sec adjustment Press repeatedly to enter in WRT function lt choose sensor to check 3 Check sensors load BBEBH individually entering 957 in WRT function shows load The sensor 9 15 indicated by a circle with its number WRT function helps to check tension of all ropes individually Press 3 sec to exit To adjust the tension of the WRT function ropes follow the next step User manual OMEGA 804 Series 4 Adjust tension of ropes with the help of rope tension monitor WRT in display as it is explained with the n
3. current value Press to enter to modify the value Press to chose the digit to change blinking and change it if there s no digit blinking change the value with o button directly Press D twice to save the value If en button is not pressed the second time before display blink ends the changes will not be stored After any of these operations the display shows the current parameter User manual OMEGA 804 Series 6 INITIAL CONFIGURATION 1 Install the control unit with the information of the INSTALL AND CONECTIONS chapter and then power up the unit with the correct voltage see the SPECIFICATIONS chapter Press 2 sec D Choose Press type of Press x2 2 Set parameter toenter to enter sensor to save SEnSo according E gt with the sensors aa gt 2 x x Display type that it is mo going to use 3 5et parameter Press number of Press x2 nSEn according to enter sensors to save with the number En A 0 of sensors that it Display is going to shows this connected Press ten Press Choose Press x2 to enter kg or Ib to save 4 Set units of measurement UnIT E A cow Display shows this Follow next configuration steps depending on the application 7 TYPES OF CONFIGURATION DEPENDING ON THE APPLICATION This system has two modes of working a can be used to adjust ropes tension WRT b can be used as
4. seconds and then exit pressing button during 3 seconds 10 Adjust tension of ropes with the help of rope tension monitor WRT in display Dinacell Electr nica S L www dinacell com ip C El torno 6 26522 Rivas Vaciamadrid Madrid SPAIN b Configuration when system is working as load weighing device LWD 5 Drive the elevator car to the middle of the shaft 6 Bounce in cabin to insure there s no friction on guides 7 Now install sensors on the ropes 8 Adjust ZERO with the cabin empty 9 Adjust LOAD with a well known weight inside the cabin 10 Set desired alarms levels 11 Set cabin display output incre for progressive display or LED 12 Set the chain compensation weight max 200 kg 92 608 1 00 11 05 2012 Tel 34 91 300 14 35 Fax 34 91 300 16 55
5. unit is wrong adjusted again RESTORING THE FACTORY SETTINGS Only in case of problems A 6 Press Press repeatedly Enter Choose Press x2 Press 2 sec simultaneously to find RESET YES to save to exit 10 SPECIFICATIONS 24 version characteristics It is not necessary to replace any fuse Nominal voltage 24V dc Maximum current 250mA Nominal frequency NENNEN 50 60 Hz Relays Contacts Normally Open 250V Box IP 50 VO fireproof plastic User manual OMEGA 804 Series 11 QUICK CONFIGURATION GUIDE Parameters checking or modification Press repeatedly to find the desired parameter to enter Press 2 sec to exit Initial configuration of the unit Make the necessary connections Modify the value ed 69 amp 3 8 amp C Check Enter to Change Choose Press x2 modify digit digit to save Set parameter Senso according with the sensors type 1 2 3 Set parameter 5 according with the number of sensors 4 Set UnITS of measurement kg or Ib Now follow steps a or b depending on the application a Configuration when system is working as a rope tension monitor WRT 5 Make sure that the sensors are not installed on the ropes 6 Set 4FEF with the value ALL 7 NOW install sensors on the ropes 8 Adjust ZERO with the cabin empty 9 Check sensors load individually pressing button during 3
6. INCRE Progressive display MB D two wire connection without polarity 2 CDISP LED Under overload it will be an intermittent voltage of 7 5V max 75mA with the polarity shown in the figure HOLD This function will be activated when an input voltage of 24 to 230V DC or AC is applied See the ADDITIONAL FUNCTIONS chapter pr RELAYS Terminals of the alarm relays r1 r1 r1 m See the alarms section in chapter 7 2 User manual OMEGA 804 Series 4 MENU STRUCTURE The menu has the cyclic structure shown in the following figure Press button for 3 seconds to enter then press it repeatedly to move from a parameter to another Press it for 3 seconds to exit 88888 Display the value of the measured load v SEn So Sets the sensor type SWK SWR TCA and LCA nSEn Sets the number of sensors to use Unl T Sets measurement units to kg or Ib TPEF Initial reference when sensors are not installed on the ropes not available when parameter SENSO is set to TCA gEPa Parameter to adjust measurement with empty car d Parameter to adjust measurement with car loaded H HL Arm Sets levels of load that change the relays status T TSOP sets the car display type incremental or LED CHAIN Sets the weight of the compensation chain 5 HOW TO CHECK OR MODIFY PARAMETERS Once inside menu and display showing the parameter to be viewed or changed Press to check the
7. ay for Overload ae amp amp Relay for Unlevel Alarm3 Wire Rope Tension Choose relay Press x2 Choose Change Fixed assignment contacts to validate digit digit Additional Relay to open or close activate MB D LED Alarm4 buzzer or other warning devices Press 2 Press Choose Press x2 toenter incre or LED to save 7 Set cabin display A C3 Ri output Display shows this 9 7 Press 2 sec Press once to go to the CHAIN parameter to exit See the ADDITIONAL FUNCTIONS chapter User manual OMEGA 804 Series 8 ADDITIONAL FUNCTIONS 8 1 HOLD FUNCTION When a voltage in the range 24 230V DC or AC is applied in this input the unit stops to measure and the last value of weight acquired will be shown in display The voltage must be applied when the doors close and the it must be removed when the doors open This ensures that the movement of the cabin will not affect the weighing process and therefore no relay will be activated during elevator travel Also when the doors are closed since no more people will be entering in the cabin there is no reason to continue the weighing process When the doors open voltage must be removed from the hold input so that the unit can begin measuring the load in the cabin 8 2 CHAIN COMPENSATION This function allows to compensate the difference of weight between floors produced by the compensation chain The unit needs the HOLD signal active when the
8. doors close to compensate the weight during the elevator movement How to set the chain compensation weight Max 200 kg Press repeatedly Press 3 sec Enter the value of the to enter Press weight of compensation to enter chain Max 200kg o n Display Choose Change shows this digit digit Press x2 to start Press 3 is adjustment to exit User manual OMEGA 804 Series 9 ERROR CODES AND TROUBLESHOOTING When the unit detects some anomaly it will show an error codes of the following Important When an error appears all alarms are activated and the elevator remains blocked Errordeseription Action Eccl iste edema man or its cable is damaged connection Negative overflow Check the load cell The load cell is giving a negative signal connection because it should too high be no negative charge Positive overflow load cell by another with Load cell is holding a higher load than higher nominal load its nominal value Polarity error This happens when the Check the load cells unit adjusts the weight with the wrong connection load cell polarity or the weight is not in Adjust the zero and weight the cabin during the adjustment again Loss of data in memory The unit must be configured Notice When this error appears every again with the properly relay will remain in OFF state values Load cell with very low sensibility Adjust the zero and weight Usually the
9. ext figure CDD 0 00 050 6 REN Les m EH EM V Ropes with sensors 1 N Sensors 7 and 8 and 2 are balanced i shows not connected Ropes with sensors 3 4 5 and 6 are NOT balanced 7 2 SYSTEM USED AS A LOAD WEIGHING DEVICE LWD 1 Drive the elevator car to the middle of the shaft 2 Bounce in cabin to insure there s no friction on guides 3 Install sensors on the ropes Press repeatedly Press 3 sec to enter Press Choose countdown to enter seconds 4 Adjust ZERO with zi A the cabin empty Display Choose Change shows this digit digit tex Press x2 to Start adjustment Wait countdown 6 Introduce inside the cabin a well known weight minimum 5096 of the elevator full load Press Press Enter the value of the real weight inside the cabin to enter 5 Adjust LOAD with the ER A cabin loaded Display Choose Change shows this digit digit Wait countdown Press x2 to start adjustment User manual OMEGA 804 Series 6 Set alarms Press D Press to enter in alarms submenu Alarms are the Choose alarm Display roerammed load m Eee shows this AL Ari RLRP levels that change AR on the state of relays HLRP3 It is not necessary ALAPY to introduce weight in the cabin A Enterto Keep modify pressed RELAYS ASSIGNMENT A to check to save Walde Relay for Full Load Enter the level Alarm2 Rel
10. put to hold function that inhibit load measure during the elevator travel 2 DISPLAY AND CONTROL BUTTONS Show alarms status Show load and value of parameters Rope tension monitor Show units Hold function status QO000 06 Control buttons Functions of control buttons a Enter exit of the menu and navigate through parameters b Accept and save modified values a When load is shown Enter in the rope tension monitor function b During menu navigation Enter to modify a parameter c While modifying a parameter Chose digit to change a During menu navigation Show the stored value of the selected A parameter b While modifying a parameter Change the blinking digit incrementally from 0 to 9 User manual OMEGA 804 Series 3 INSTALLATION AND CONNECTIONS eC SENSORS CONNECTION USB 7 Sensors input Power supply input Two versions Cabin display output HOLD input Relay connections for alarms RELAYS 4 POWFR 5 3 2 1 SUPPLY CE Dinacell 27 SENSORS CONNECTION USB 4 1 2 wq Ww RT 3 USB sockets for load cells SWK SWR TCA LCA 24Vdc version 80 260Vac version mm 9 24V dc Non polarity Earthed 80 260V ac power supply It provides two types of output depending on the CDISP parameter 1 CDISP