Home
Adam Equipment WARRIOR SERIES USER MANUAL
Contents
1. e To delete a Tare value press 0 T when the pan is empty 6 3 WEIGHING A SAMPLE To determine the weight of a sample first tare the empty container if it is to be used and then place the sample in the container The display will show the net weight of the sample and the unit of weight currently in use e 7 0 7 0 A Jt Ui 9 Adam Equipment Company 2012 6 4 PARTS COUNTING If parts counting is enabled See section 7 4 in the full manual it is possible to count parts using a sample of the parts to determine an average piece weight e f using an empty container place the container on the top pan and press 0 T to zero the display Press the PCS key to enter parts counting mode e The scale will show P 10 Change the sample size to the desired quantity by pressing the PCS T1 key It will cycle through the options 10 20 50 100 200 and back to 10 e Place the nominated sample size into the container and press 0 T The sample number should match the sample amount options available for parts counting i e 10 20 50 100 or 200 pieces e The display will now show the amount of parts in the container and as more parts are added the display will increase to show the number of parts in the container at that time PCS Pressing the Unit lt key will display the net weight PCS and kg pressing it a second time will display the unit weight g pcs and the third time will display the count aga
2. is pressed the display will first show Fun 1 for Check weighing parameters e Press either the Func C key or the PCS M to advance through the groups Fun 1 Fun 2 Fun 3 and Fun 4 Press 0 T to enter the desired group of parameters e When in one of the sections press Print M Esc to return to the group Fun T If you press Print M Esc again the scale will exit the User Parameter section and return to normal weighing Complete details of all parameters can be found in of the full version of the user manual 11 Adam Equipment Company 2012 8 0 BATTERY OPERATION The scales can be operated from the battery if desired The battery life can be up to 70 hours depending on the load cells and how the backlight is used battery symbol is shown on the display which indicates the current charge of the battery 3 bars means fully charged When just the outline of the battery and no bars are visible the battery needs to be re charged To charge the battery simply plug the adaptor into the mains power and also into the input connector on the rear of the Indicator marked DC 12V The scale does not need to be turned on The battery should be charged for 12 hours to reach full capacity Near the display is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is green the battery has a full char
3. Function parameters of the scale A secondary function C is to act as a clear key when clearing an accumulated total Sends the results to a PC or a Printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulation function is not automatic A secondary function ESC is to return to normal operation when the scale is in a Parameter setting mode To switch the Indicator on or off The WARRIOR will store the weighing unit and the check weighing values currently in use if power is powered off These will be re called when the Indicator is next powered on 5 0 DISPLAYS The LCD display will show a value as well as the unit currently being used In addition the LED s above the display will show when a weight is below inside or above the check weighing limits Low OK High gt gt 0 r sf es ee Je fs ff es ff ce ff ff mf 100 CN Coro SA Hold Uhr kg g Pcs M Ib oz I Other symbols will show when a weight has been tared NET the scale is at zero and stable if a value has been stored in memory or when the animal weighing function has been enabled A battery symbol will show the state of charge of the internal battery 7 Adam Eguipment Company 2012 6 0 OPERATION 6 1 ZEROING THE DISPLAY e You can press the 0 T key at any time to set the display to zero This will usually be when the platform is empty When the
4. O O O een 16 WARRANTY INFORMATION tege o odnosn 17 Adam Equipment Company 2012 1 0 INTRODUCTION The WARRIOR series provide accurate fast and versatile general purpose type weighing scales with parts counting percentage weighing and check weighing functions The WARRIOR has LED s next to the display to indicate when a weight is below the low limit in between the limits or above the high limit These can work in conjunction with an audible alarm for check weighing as well as the display showing LO OK and HI The WARRIOR is supplied with a RS 232 bi directional interface and real time clock RTC The WARRIOR has a sealed keypad with colour coded membrane switches a large easy to read liquid crystal display LCD and a green backlight Included functions are automatic zero tracking semi automatic tare and an accumulation facility that allows the weight to be stored and recalled as an accumulated total 1 Adam Equipment Company 2012 2 0 SPECIFICATIONS Model WSK 8 WSK 16 WSK 32 WBK 32 WBK 75 WSK 16a WSK 35a WSK 70a WBK 70a WBK 165a Maximum Capacity 8000g 16lb 16kg 35lb 32kg 70lb 32kg 70lb 75kg 165lb Readability 0 5g 0 0011b 0 001kg 0 0021b 0 002kg 0 005Ib 0 002kg 0 005lb 0 005kg 0 011b Resolution 1 16000 1 16000 1 16000 1 16000 1 15000 Pr 19 0 002lb 0 002kg 0 004Ib 0 004kg 0 01lb 0 004kg 0 01lb 0 01kg 0 021b Linearity 1g 0 0021b 0 002
5. balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website www adamequipment com Adam Equipment Company 2012
6. SES ADAM O Adam Equipment WARRIOR SERIES USER MANUAL Adam Equipment strives to be more environmentally focused and uses recycled materials and environmentally friendly packaging where possible As part of this initiative we have developed a short manual that uses less paper and ink to describe the main functions of your new Adam product A complete version is available at www adameguipment com Thank you for your support of Adam Eguipment P N 3136611622 Revision B April 2012 Adam Eguipment Company 2012 Adam Equipment Company 2012 CONTENTS 10 INTRODUCTION MR O O ecg I 1 P V 2038110 C R V rs in tes 2 5 0 INSTALLATION PA P P e 4 SCH UNPACKING tee ia o on 4 E TEE 4 3 3 SETTING UP THE SCALES menus 5 410 KEY DESCRIPTIONS erte reueg ee EE 6 BOE DS AP CAD EE RER O ae 7 GO EC 8 6 1 ZEROING THE DISPEAY st not a nu evi Ne cn demie 8 Get RING ht a O ote O ne O rent Me 8 6a EIERE EE 9 64 PARIS COLNTING 3 manne ie tue Seen ls urate ne AM NES 10 Gb REENEN EE 10 6 6 SAOCUMULATE TOTAL eu A ene ue eos tenants 11 6 7 PERCENTAGE WEIGHING aere 11 66 ANIMAL Dynamic RIESEN 11 To USER PARAMETERS un ee 0a nn R ena 11 807 ERR EE 12 90 4 RS 232 TERA CE nee nm gra O 12 D INPUT COMMANDS FORMAT eet reiege lol ln 13 10 07 RELAY INTERFACE Lutin nr De nes deu nt dc bound 13 11 0 CALIBRATION eege 14 12 0 SERVICE PARAMETERS cation on ooo or lo os ee 15 12 1 USING THE SERVICE PARAMETERS vvn 15 13 0 ERROR CODES RR R
7. accumulation memory if the accumulation function is not set to automatic 10 0 RELAY INTERFACE The indicator is supplied with drivers to control external relays The drivers could be used to control a number of different relays depending upon the users needs The relay drivers are isolated outputs requiring the use of an external power supply and the relay option kit See of the full version of the user manual for complete details 13 Adam Equipment Company 2012 11 0 CALIBRATION The scale can be calibrated using the following procedure To enter this procedure it is necessary to use Func 4 which is accessible using the Func C key as described in section 7 4 in the full manual or by using the passcode access as described in section 12 0 The scales calibrate using either metric or pound weights depending on the weighing unit being used before calibration The display will show either kg or lb to identify the weights expected PROCEDURE Enter the calibration section using Func 4 C8 CAL or using the passcode as described in section 12 0 The display will show unLoRd Remove any weight from platform and when the stable symbol is on press 0 T The display will show Ld then 0000XK which shows the last calibration weight used Place this calibration weight on the scale and press the 0 T key If the weight you put on the scale does not match the value displayed press the Func C key to clear the v
8. al 15 Adam Equipment Company 2012 13 0 ERROR CODES ERROR DESCRIPTION SUGGESTIONS CODES oL Over range Remove weight from the scale If the problem persists contact your dealer or Adam Eguipment for assistance Err 1 Time Setting Enter time using correct format and reasonable Error values Format hh mm ss Err 2 Date Setting Enter date using correct format and reasonable Error values Format yy mm dd Err 4 Zero Setting The scale was outside the normal zero setting Error range either when it was turned on or when the Zero key was pressed Remove weight from the scale and try re zeroing again Use the 0 T key to set the display to zero value If the problem persists contact your dealer or Adam Eguipment for assistance Err 6 A D out of range The values from the A D converter are outside the normal range Remove the weight from the scale if overloaded Make sure the pan is fitted correctly Indicates the load cell or the electronics may be faulty If the problem persists contact your dealer or Adam Equipment for assistance Err 9 Check weigh Shown if the low limit is set higher than the current limits error high limit Reset High limit or change the low limit FAIL Calibration Improper calibration should be within 10 of the error factory calibration The old calibration data will be retained until the calibration process is complete If the problem persists contact your deale
9. ale then use the Unit lt key and PCS N key to set the correct value When it is correct press 0 T If the calibration is acceptable the scale will run a self test during which the calibration weight should be removed If an error message FAIL L is shown try calibration again as a disturbance may have prevented a successful calibration After calibration the scale should be checked to verify the calibration is correct If necessary repeat the calibration making sure that the scale is stable before accepting any weight 14 Adam Eguipment Company 2012 12 0 SERVICE PARAMETERS The scales will allow entry to the parameters if the Tare key is pressed during the power on cycle The passcodes work as explained earlier In this case the display will show the passcode request screen P To continue enter a passcode as described below Entering passcode 0000 will allow calibration as shown in section 11 Entering 1000 will allow access to a limited set of parameters described in section 12 1 12 1 USING THE SERVICE PARAMETERS Press the 0 T key during the display countdown when turning on When P is displayed enter the number 1000 using the Uni lt and PCS T keys and then press 0 T The display will show the first parameter called F4 Int To select another parameter press the PCS T key which will advance through the parameters available Full details are in the full version of the user manu
10. ge If it is red the battery is nearly discharged and yellow indicates the battery is being charged 9 0 RS 232 INTERFACE The WARRIOR indicator is supplied with bi directional RS 232 interface as standard The scale when connected to a printer or computer outputs the weight with the selected weighing unit through the RS 232 interface Specifications RS 232 output of weighing data ASCII code 9600 Baud user selectable 8 data bits No Parity 12 Adam Equipment Company 2012 The RS 232 serial interface is located inside the housing access is gained by removing the 8 x case screws whereby connections can be made to COM 1 as shown below RXT Received Data TXT Transmitted Data GND Signal Ground The cable used should be routed through the gland marked RS 232 on the case and tightened securely to ensure a watertight connection is made The scale can be set to print text in English French German or Spanish See the RS 232 parameters section for details 9 1 INPUT COMMANDS FORMAT The scale can be controlled with the following commands Press the Enter key of the PC after each command T lt cr gt lt lf gt Tares the scale to display the net weight This is the same as pressing 0 T Z lt cr gt lt lf gt Sets the zero point for all subsequent weighing The display shows zero P lt cr gt lt lf gt Prints the results to a PC or printer using the RS 232 interface It also adds the value to the
11. in PCS e Press the PCS M key to return to normal weighing Press the PCS key again to start counting a different sample 6 5 CHECK WEIGHING Check weighing is a procedure where the LED s come on and if enabled an alarm to sound when the weight on the scale meets values stored in memory The memory holds the last values for a high and a low limit when the power is turned off The user can set either one limit or both see the full version of the user manual for details of the check weighing function 10 Adam Equipment Company 2012 6 6 ACCUMULATED TOTAL e The scale can be set to accumulate manually by pressing the Print M Esc key or automatically when a weight is removed from the scale See the Section 7 3 of the full manual for details 6 7 PERCENTAGE WEIGHING The scale can be set to perform percentage weighing See Section 7 2 of the full version of the user manual for complete details 6 8 ANIMAL Dynamic WEIGHING The scale can be set to animal dynamic weighing for weighing any items that are unstable or may move See Section 7 4 of the full version of the user manual for complete details 7 0 USER PARAMETERS Pressing the Func C key during normal operation allows the user to access the parameters for customizing the scale The parameters are split into 4 groups 1 Check weighing parameters 2 Percentage and Animal Weighing Functions 3 RS 232 parameters 4 Scale parameters e When Func C
12. kg 0 0041b 0 004kg 0 011b 0 004kg 0 011b 0 01kg 0 021b jus 250mm x 250mm 9 8in x 9 8in 300mm x 400mm 11 8in x 15 7in SC or g Kg Lb Lb oz Newtons Ounces easure m 2 3 Secs ime sue 10 to 400 32F to 104F emperature Power S ppi 6v 4 5Ah battery ppy 12VDC 800mA External adaptor Calibration External Calibration User Selectable Mass Display Backlit Green display 40mm high digits with capacity tracker S 304 Stainless steel housing IP66 rated ousing Adam Equipment Company 2012 Model WFK 75 WFK 150 WLK 150 WFK 165a WFK 330a WLK 330a Maximum Capacity 75kg 165lb 150kg 330lb 150kg 330lb Readability 0 005kg 0 011b 0 01kg 0 021b 0 01kg 0 021b Resolution 1 15000 1 15000 1 15000 Repeatability Std Dev 0 01kg 0 021b 0 02kg 0 041b 0 02kg 0 041b Linearity 0 01kg 0 021b 0 02kg 0 041b 0 02kg 0 041b on 400mm x 500mm 15 7in x 19 7in 450mm x 600mm 17 7in x 23 6in Units of Measure g Kg Lb Lb oz Newtons Ounces Stabilization Time 2 3 Secs Nay 10 to 440 32F to 104F emperature Power Suppl 6v 4 5Ah battery PRY 12vDC 800mA External adaptor Calibration External Calibration User Selectable Mass Display Backlit Green display 40mm high digits with capacity tracker SE 304 Stainless steel housing IP66 rated ousing 3 Adam Equipment Company 2012 3 0 INSTALLATION 3 1 UNPACKING The WARRIOR scales have already been adjusted to work with a platf
13. n used for protection e Fix the pillar to the base bracket fitting using the screws provided e Adjust the viewing angle of the Indicator to the ideal position and tighten the 2 x locking handles e Level the scale by adjusting the five feet on the WSK WBK or the four feet on the WFK WLK If the scale rocks re adjust the feet e Attach the power to the indicator and press the On Off key The software revision number will be displayed followed by a self test showing all digits before the zero is displayed along with the unit of weight that was last used 5 Adam Equipment Company 2012 4 0 KEY DESCRIPTIONS H ADAM WARRIOR Low OK High CH ESC ej e Used to reset the display to zero Tares the scale Used to deduct and store the weight currently on the scale if it is not required as part of the final weighing result A secondary function l is of an Enter key used when setting up a value for the Parameters Selects parts counting Used to set the sample quantities while parts counting A secondary function is of incrementing the active digit when setting a value for Parameters Selects the weighing unit to be displayed from those which are enabled See parameter S1 in section 7 4 in the full manual A secondary function is to move the active flashing digit to the left when setting values for Parameters 6 Adam Equipment Company 2012 o Selects the
14. nt to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment WEEE COMPLIANCE Sealed Lead Acid Battery Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2012 ADAM EQUIPMENT is an ISO 9001 2008 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Health and Fitness retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers
15. orm and have been configured for this application The platform and indicator have been calibrated as a pair and must be used together 3 2 LOCATING ZE e The scales should not be placed in a location that will reduce the accuracy om e Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents e Avoid unsuitable tables The table or floor must be rigid and not vibrate e Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors e Do not place near vibrating machinery ta ke D e Avoid high humidity that might cause condensation 2 Avoid direct contact with water Do not spray or 4 immerse the scales in water e Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents L e Keep the scales clean Do not stack material on the scales when they are not in use 4 Adam Equipment Company 2012 3 3 SETTING UP THE SCALES e Remove the Indicator from its box and fix it to the U shaped bracket using the 2 x fixing handles Take the Indicator and place it onto the pillar ensuring the slack cable is pushed inside Fix the Indicator to the pillar using the screw provided e Remove all upper internal packaging place the pillar into the base bracket fitting and remove the complete machine from the box Remove any plastic bags that may have bee
16. r or Adam Equipment for assistance 16 Adam Equipment Company 2012 WARRANTY INFORMATION Adam Equipment offers Limited Warranty Parts and Labour for the components failed due to defects in materials or workmanship Warranty starts from the date of delivery During the warranty period should any repairs be necessary the purchaser must inform its supplier or Adam Equipment Company The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems However any freight involved in sending the faulty units or parts to the service centre should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual Additionally rechargeable batteries where supplied are not covered under warranty Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The
17. statutory right of the purchaser is not affected by this warranty The terms of this warranty is governed by the UK law For complete details on Warranty Information see the terms and conditions of sale available on our web site 17 Adam Equipment Company 2012 Adam Equipment Company 2012 Adam Equipment Company 2012 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Equipment Co Ltd Maidstone Road Kingston Milton Keynes MK10 OBD United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipme
18. zero point is obtained the display will show an indicator for zero Low OK High zs UT UUU LA o wk sl III I l I 100 e The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to press the 0 T key to re zero the scale if small amounts of weight are shown when the platform is empty 6 2 TARING e Zero the scale by pressing the 0 T key if necessary The ZERO indicator will be ON Low OK High UT e Place a container on the platform and a value for its weight will be displayed Adam Equipment Company 2012 e Press the 0 T key to tare the scale The weight is deducted and stored as the tare value leaving zero on the display The NET indicator will be ON and as a product is added only the net weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will be displayed Low OK High s nnnn VUV 100 ell e When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight which includes the container and the entire product it contains The ZERO indicator will be on to indicate that the platform is back to the same condition as it was when zero was last set