Home
VOLT Q3 User Manual ver 1
Contents
1. _ SF HN NW 3m TU a NG ew 4m m ft m ft m ft Distance 2 6 6 3 9 8 4 13 1 7 Beam Diameter 0 26 0 9 0 38 1 2 0 51 1 7 13 Field Diameter 0 47 1 5 0 68 2 2 0 92 3 0 Photometrics lux fc lux fc lux fc REDLEDs 1 460 136 625 58 355 33 GREEN LEDs 3 567 331 1 609 149 930 86 BLUE LEDs 490 46 220 20 126 12 WHITE LEDs 4 508 419 1 970 183 1 127 105 FULLON 8 920 829 3 892 362 2 193 204 Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice DIMENSIONAL DRAWINGS IG kb il IN A 215mm Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 32 VOLT Q3 User Manual ver 1 www elationlighting com OPTIONAL ACCESSORIES ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp EWDO01 EWDMX IP Wireless IP65 DMX Transceiver VOLT5CHARGER VOLT Q3 17 5 VDC Charger IEC Power Cable VOLT 3MDLC VOLT Series 9 8 ft 3M 3pin Male IP to 3pin Female IP DATA LINK Cable VOLT DIAC VOLT Series 9 8 ft 3m 3pin IP Female to 3pin DMX Male DATA INPUT Cable VOLT DOAC VOLT Series 9 8 ft 3M 3pin Female IP to 3pin DMX Female DATA OUTPUT Cable 33 VOLT Q3 User Manual ver 1
2. Prog 1 10 Program 2 Select Programs To Be Run Pro Part3 Prog 1 10 Program 3 Prog 1 ProgTest Testing Program Edit Prog A EdStep01 SCxxx Program In Loop EditProg Prog 10 EdStep64 SCxxx Save and Exit Auto Save and Automatically Return Scen001 EditScen Scen Time Manual Scenes Edit Scen250 InByOut Stores Scenes via Ext DMX Console RecCn r XX XX Automatic Scenes Recorder 19 VOLT Q3 User Manual ver 1 www elationlighting com FuncMode Address Define desired DMX address via the Control Panel ValuDisp Display DMX 512 value of each channel SetSlave Define fixture slave mode Slavel Slave2 Slave3 AutoProg Define fixture mode Master or Alone for running Auto Programs Select desired internal programs under Sel Prog set the number of steps under EditProg and edit individual scenes under EditScen Info Timelnfo Cur Time Displays fixture run time from last power ON The counter is reset after each time the fixture is powered OFF TotalHrs Displays fixture total run time Last Hrs Displays fixture run time for a given period of time i e rental period This counter can be reset TimePass Display the fixture timer password 038 Cir Last Resets the last run time of the fixture Tempinfo HeadTemp Displays temperature of the fixture Battlnfo Displays the charge level of the battery Soft Ver Displays soffware version of the fixture
3. listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture You can set the same starting address for all fixtures or a group of fixtures or set different address for each individual fixture Be advised that setting all fixtures to the same DMX address will subseguently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the VOLT G3 M when in the 9 Channel Extended Mode you should set the starting DMX address of the first unit to 1 the second unit to 10 1 9 the third unit to 19 10 9 and so on Note During start up the VOLT G3 will automatically detect whether a DMX data signal is being received or not If DMX data signal is being received the display will show Addr XXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX sig
4. 20 VOLT Q3 User Manual ver 1 Persnal Stat Set www elationlighting com Addr DMX When ON define the desired DMX address via an external controller l Connect the fixture to the external controller and power ON 2 Set the DMX value of Channel 1 on the controller to 7 3 Set the DMX value of Channel 2 on the controller to 7 or 8 When set to 7 the DMX address can be set between 1 and 255 When set to 8 the DMX address can be set between 256 and 511 4 Using Channel 3 on the controller set the desired DMX address of the fixture Example 1 If the desired DMX address is 57 set Channel 1 to a value of 7 set Channel 2 to a value of 7 and then set Channel 3 to a value of 57 Example 2 If the desired DMX address is 420 set Channel 1 to a value of 7 set Channel 2 to a value of 8 and then set Channel 3 to a value of 164 256 164 420 5 After setting Channel 3 to the desired DMX address value wait for approximately 20 seconds for the fixture to complete the address reset function NoDMXSta Define how fixture operates if NO DMX signal is detected Disp Set Off Time Define minutes before the LCD Menu display will automatically shut OFF Key Lock When ON Control Panel buttons lock automatically after exiting main menu for 15 seconds To unlock keep MODE ESC button pressed for 3 seconds Temp C F Define how fixture displays internal temperature Celsius or Fahrenheit 21 V
5. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 13 VOLT Q3 User Manual ver 1 www elationlighting com MOUNTING POINTS e Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury e Fixture is fully operational in the specific mounting positions as illustrated below IE A WI XL XA XA XX Ee a a UA n PS U U p _ VAY is j db ING N IA N AN L SIN SZ T SZ SAA AS GG SL I AN a Sa SSA eS ci FX ZZ Mar SAFETY CABLE Always use a Safety Cable whenever installing this fixture in a suspended environment to ensure the fixture will not drop if the clamp fails 14 VOLT Q3 User Manual ver 1 www elationlighting com UNDERSTANDING DMX DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers DMX allows all makes and models of different manufactures to be linked together and operate from a single controller This is possible as long as all the fixtures
6. flash rapidly for 5 10 seconds while the two systems pair e Once the fixture is paired with the EWDMX Transmitter T1 the EWDMX status indicators on the both the fixture and the EWDMX Transmitter will stop flashing and glow solid GREEN If paring is unsuccessful repeat the process until paring is secured The fixture will store the pairing information inside a nondestructive memory bank once a link is created between the fixture and an EWDMX Transmitter The fixture will remember the paired EWDMX Transmitter even if the fixture is turned OFF for extended periods of time 26 VOLT Q3 User Manual ver 1 www elationlighting com CLEARING EWDMX TRANSMITTER LINK e Access the fixture s main menu and toggle to the PERSNAL menu then access the WDMX sub menu and select CIrWwDMX to clear any existing link between the fixture and a EWDMX Transmitter The EWDMX indictor on the fixture will turn solid RED when the link is severed e You may also clear the link directly from the EWDMX Transmitter First be sure the fixture s is powered ON and then hold down the configuration button on the WDMX Transmitter for as least 5 seconds This will automatically clear the link between the EWDMX Transmitter and any fixture that is powered ON All EWDMX indictors will glow solid RED if the procedure was successful EWDMX INDICATORS RED GREEN Rapid Flashing Syncing to a EWDMX Transmitter RED GREEN Slow Flashing Paired with
7. 16 223 Color Macro 28 224 231 Color Macro 29 232 239 Color Macro 30 240 247 Color Macro 31 248 255 Color Macro 32 28 VOLT Q3 User Manual ver 1 ELATION www elationlighting com ELATION VOLT Q3 DMX Channel Values Functions 9 DMX Channels Specifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 4CH 5CH 7CH 9 CH 0 NO Function 1 30 Chase Macro 1 31 60 Chase Macro 2 61 90 Chase Macro 3 91 120 Chase Macro 4 121 150 Chase Macro 5 151 180 Chase Macro 6 181 210 Chase Macro 7 211 255 Chase Macro 8 OB 0 31 LEDs OFF 32 63 LEDs ON NO STROBE 64 95 STROBE Effect SLOW to FAST 8 96 127 LEDs ON NO STROBE 128 159 STROBE Pulse Effect In Seguences 160 191 LEDs ON NO STROBE 192 223 Random STROBE Effect SLOW to FAST 224 255 LEDs ON NO STROBE 5 l E 0 255 Intensity O to 10096 29 VOLT 3TM User Manual ver 1 www elationlighting com CLEANING AND MAINTENANCE C A U T O N Disconnect power before cleaning or maintenance CLEANING Frequent cleaning is recommended to insure proper function optimized light output and an extended life The frequency of cleaning depends on the environment in which the fixture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture
8. 3 User Manual ver 1 ELATION www elationlighting com ELATION VOLT Q3 SYSTEM MENU Specifications and features are subject to change without any prior written notice MAIN MENU SUB MENU OPTIONS VALUES Default Settings in BOLD DESCRIPTION Address A001 AXXX DMX Address Setting ValuDisp ALL DMX Value Display PungMode SetSlave Slavel Slave2 Slave3 Slave Setting AutoProg Master Alone Auto Program Cur Time XXXX Hours Fixture Run Time From Power ON TotalHrs XXXX Hours Fixture Total Run Time Timelnfo Last Hrs XXXX Hours Clear Fixture Last Run Time Info TimePass Password XXX Password 038 Clr Last ON OFF Reset Fixture Last Run Time Templnfo HeadTemp XXXC F Temperature in Fixture Head BattInfo 0 100 Battery Charge Level Soft Ver V1 1 0 Software Version Stat Set Addr DMX ON OFF Address Via DMX NoDMXSta CloShut Hold Auto Auto Run If No DMX Disp Set Off Time 02 59m 05m Display Shut Off Time Key Lock ON OFF Key Lock Temp C F Cels Fahren Temperature Switch Between C F Persnal Man Hold ON OFF Manual Hold WDMXOff ActWDMX ee AcDaOut CIWMX Reset Default ON OFF Restore Factory Settings MancCnitrl MancCntrl AMO Red Gree Blue Whit Sto Manual Control Dimm Macr Temp 4CH 5CH Mode Set User Mode 7CH DMX Channel Modes 9CH ProPart1 Prog 1 10 Program 1 Sel Prog Pro Part2
9. ELATION PROFESSIONAL ELATION VOlT 3 user manual VOLT Q3 User Manual www elationlighting com 2013 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade Netherland
10. ENERAL GUIDELINES NEVER OPEN THIS FIXTURE WHILE IN USE During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and Will decrease gradually over time Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating to prevent any fire hazard Minimum distance of inflammable materials from the surface 1 6 feet 0 5m DO NOT attempt installation and or operation without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come DO NOT shake fixture avoid brute force when installing and or operating fixture Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the bracket of the fixture Use the original packaging and materials to transport the fixture in for service DO NOT TOUCH the housing bare hand during its operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before re
11. OLT Q3 User Manual ver 1 www elationlighting com Man Hold WDMX Control the functionality of the internal wireless WD MX receiver ResetDef When ON all factory settings are restored ManCntrl MancCnitrl Select and manually test and fine adjust each individual channel function Independently from DMX control board This function will cancel all effects open the shutter and the dimmer is set to 100 With the individual functions you can focus the light on a flat surface wall and perform fine adjustments Mode Set UserMode Select operating mode which includes DMX Channel and User defined modes EditProg Sel Prog Select one of the 10 user defined internal Auto Programs EditProg Edit any of the 10 user defined internal Auto Programs EditScen Edit any of the scenes of the internal Auto Programs RecCntrl The fixture features an integrated DMX recorder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head 22 VOLT Q3 User Manual ver 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Programs A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master u
12. TIO www elationlighting com LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional amp products to be free of manufacturing defects in material and workmanship for a period of two years 730 days and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months 180 days from the original date of purchase This warranty excludes discharge lamps and all product accessories This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional will pay return shipping charges only to a designated point within the United States If any product is sent it must be shipped in its original package and packaging material No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional shall have no liability what so ever for loss and or or damage to any such accessories nor for the safe return thereof C This warran
13. a EWDMX Transmitter but not receiving a DMX signal from a controller GREEN Solid Paired with a EWDMX Transmitter and receiving DMX data RED Solid Not paired with a EWDMX Transmitter FREE 27 VOLT Q3 User Manual ver 1 ELATION www elationlighting com DMX CHANNEL FUNCTIONS AND VALUES ELATIONO VOLT Q3 DMX Channel Values Functions 9 DMX Channels Specifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 4 CH 5 CH 7 CH 9 CH i i LL iy rrr 0 255 Red 0 10096 j 5 3 gt E 0 255 Green 0 100 sl a 0 255 Blue 0 10096 i a 0 255 White 0 10096 5 5 0 NO Function 1 255 1 2 700K 255 7 200K OLO ACRO 0 NO Function 1 7 Color Macro 1 8 15 Color Macro 2 16 23 Color Macro 3 24 31 Color Macro 4 32 39 Color Macro 5 40 47 Color Macro 6 48 55 Color Macro 7 56 63 Color Macro 8 64 71 Color Macro 9 72 79 Color Macro 10 80 87 Color Macro 11 88 95 Color Macro 12 96 103 Color Macro 13 04 111 Color Macro 14 12 119 Color Macro 15 j 20 127 Color Macro 16 28 135 Color Macro 17 36 143 Color Macro 18 44 151 Color Macro 19 52 159 Color Macro 20 60 167 Color Macro 21 68 175 Color Macro 22 76 183 Color Macro 23 84 191 Color Macro 24 92 199 Color Macro 25 200 207 Color Macro 26 208 215 Color Macro 27 2
14. and the controller are DMX compliant A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light DMX data is sent out as serial data that travels from fixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use the VOLT series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual When using several DMX fixtures try to use the shortest cable path possible Never split a DMX line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain The VOLT Q3 can be controlled via DMX 512 protocol and the DMX address is set via the control menu 15 VOLT Q3 User Manual ver 1 www elationlighting com DMX 512 CONTROLLER CONNECTION Connect the provided XLR cable to the female XLR output of your controller and the other side to the male 3pin input of the VOLT Q3 The diagram below illustrates a typical DMX 512 connection when the fixture is in
15. ce 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail support elationlighting eu 5 VOLT Q3 User Manual ver 1 www elationlighting com WARRANTY REGISTRATION Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 IF IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 6 VOLT Q3 User Manual ver 1 ELA
16. eceiver which is fully compatible with an Elation Wireless DMX System WORKING WITH THE INTERNAL WIRELESS DMX EWDMX System Access the WDMX sub menu from the PERSNAL menu The WDMX sub menu allows you to ACtWDMX turn the system ON AcDaOut turn the system ON and send DMX data out through DMX OUT port WDMXOff turn the system OFF or CIrWDMX clear the EWDMX system When the EWDMX system is in the ACtWDMX mode the internal DMX IN XLR jacks are turned OFF However the internal DMX OUT XLR jacks will function normally If the fixture is powered ON with the internal EWDMX system ActWDMX it will automatically scan for a wireless DMX signal from an Elation Wireless DMX Transmitter If NO wireless signal is received it will switch to the wired DMX mode WARNING NEVER connect a fixture to a controller via a DMX cable when the EWDMX system is in use This could cause serious damage to the controller SETTING UP THE EWDMX SYSTEM Follow the instructions included with the Elation EWDMX Transmitter and connect it to the output of your DMX controller To sync your fixture with the Elation EWDMX Transmitter follow the steps below e Initially the EWDMX indicator on the fixture should be solid RED e Press and hold the configuration button on your EWDMX Transmitter for about 3 seconds The RED GREEN LED indicators on the EWDMX Transmitter and the fixture should then begin to
17. er 1 ELATION TECHNICAL SPECIFICATIONS FEATURES IP65 Rated 7 Beam and 13 Field Angles 180 Manual LED Head Positioning Variable Color Correction 2 700K 7 200K Internal Wireless EWDMX Receiver Rechargeable Lithium lon Battery Flicker Free Operation for TV and FILM Rugged Die Cast Aluminum Exterior Rubber Padded Base and Retractable Carrying Handle SOURCE 3 15W QUAD Color RGBW LEDs 100 000 Hour Average Life EFFECTS Variable Color Correction 2 700K 7 200K Magnetic Frost Filter Gel Frame Electronic Strobe and Dimming Multiple Color and Chase Macros CONTROL CONNECTIONS 4 DMX Channel Modes 4 5 7 9 Internal Wireless EWDMX Receiver 4 Button Control Panel LCD Menu Display 3pin IP DMX In Out 2pin IP Power Charger In SIZE WEIGHT Length 9 8 250mm Width 8 5 215mm Vertical Height 10 9 276mm Weight 13 0 Ibs 5 9 kg ELECTRICAL THERMAL DC 13 17 5V 40W Max Power Consumption each unit 14 F to 118 F 10 C to 45 C INSTALLATION Rigging Clamps Not Included Floor Working Position Any 360 www elationlighting com Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 31 VOLT Q3 User Manual ver 1 www elationlighting com PHOTOMETRIC DATA 7 N ee i ka 8 N 7 13 Beam Field wm
18. er Manual ver 1 www elationlighting com UNPACKING Thank you for purchasing the VOLT Q3 by Elation Professional Every VOLT 3 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting Customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 Charging Power Supply IEC Power Cable 1 9 8 ft 3M 3pin IP Female to 3pin IP Male DATA LINK Cable 1 9 8 ft 3M 3pin IP Female to 3pin DMX Male DATA INPUT Cable 1 Magnetic Frost Filter 1 Omega Bracket 1 Safety Cable CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or suggestions For service related issue please contact Elation Professional ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voi
19. ice falls under PROTECTION CLASS 1 It s essential this device be grounded properly Only qualified personnel should perform all electrical connections C A U T l O N S UNPLUG POWER BEFORE SERVICING FIXTURE NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord Do not charge this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating 8 VOLT Q3 User Manual ver 1 www elationlighting com G
20. ith respect to any accessory supplied with the products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professional in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty periods set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said periods have expired The consumer s and or dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional be liable for any loss and or damage direct and or consequential arising out of the use of and or the inability to use this product G This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 7 VOLT Q3 User Manual ver 1 ELATION www elationlighting com B gt b gt e SAFETY INSTRUCTIONS The VOLT G3 is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This dev
21. ized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 113 F 10 45 C Do not use the fixture outside above or below this temperature range Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 130 Ibs 59 kg Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing 12 VOLT Q3 User Manual ver 1 www elationlighting com CLAMP MOUNTING The VOLT G3 provides a unigue mounting bracket assembly that integrates the bottom of the base the included Omega Bracket and safety cable rigging point in one unit see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamps to the included omega brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrated in the base assembly 1 Omega holders 2 Clamp 3 Safety rope 4 Quick lock fastener SECURING Regardless of the rigging option you choose for your VOLT 83 always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above
22. m is to be sent Selection Prog 1 means that the Slave unit runs the same program as the master units Press ENTER to confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select EditProg Press ENTER to confirm Select the desired program With this function you can edit specific scenes into a specific program Press ENTER to confirm Press MODE ESC in order to return to the main menu 5 Automatic Scene Recording Select EditProg Press ENTER to confirm Select EditScen Select desired scene numbers A maximum of 250 scenes can be programmed Press ENTER to confirm Press MODE ESC in order to return to the main menu 24 VOLT Q3 User Manual ver 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued Example Prog 2 includes scenes 10 11 12 amp 13 Prog 4 includes scenes 8 9 amp 10 Prog 6 includes scenes 12 13 14 4 15 ProPartl is Prog 2 ProPart2 is Prog 3 ProPart3 is Prog 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture Part 1 af saan sen senu mewn Part 2 owns sees senu sm Part 3 i i f i 25 VOLT Q3 User Manual ver 1 www elationlighting com INTERNAL WIRELESS DMX RECIEVER EWDMX The VOLT Q3 is equipped with an internal Elation Wireless DMX R
23. ments and has been designed with an enclosure that effectively protects the ingress entry of external foreign objects such as dust and water The International Protection IP rating system is commonly expressed as IP Ingress Protection followed by two numbers i e IP65 where the numbers define the degree of protection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environment installations Installing this fixture in a marine and or coastal environment may cause corrosion and or excessive wear to the interior and or exterior components of the fixture Damages and or performance issues resulting from installation in a marine and or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and or repairs OPTIONAL CORROSION RESISTANT COATING Optional Corrosion Resistant Coatings may be available for this fixture Please consult your Elation Professional sales representative for details 4 VOLT Q3 Us
24. nal please check the following The 3pin XLR input plug cable with DMX signal from controller is not connected or is not inserted completely into the DMX input jack of the fixture The DMX controller is switched off or defective The DMX cable or connector is defective A DMX terminator has been inserted into the last fixture in your DMX chain 17 VOLT Q3 User Manual ver 1 www elationlighting com FIXTURE MENU ON BOARD SYSTEM MENU The VOLT Q3 comes with an easy to navigate system menu The next sections will cover how to access each menu function LCD MENU CONTROL PANEL The control panel located on the front of the fixture allows you to access the main menu and make all necessary adjustments to the VOLT Q3 During normal operation pressing MODE ESC button once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus With the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MODE ESC button p Wireless INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON the display shows the following information Wait VOLT a3 18 VOLT Q
25. nit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu SetSlave the Master unit sends Prog 1 to the Slave unit If set to Slave 2 the Slave unit receives Prog 2 To start an Auto Program proceed as follows 1 Slave Setting e Select FuncMode Press ENTER to confirm Select SetSlave Press ENTER to confirm Select Slave 1 Slave 2 or Slave 3 Press ENTER to confirm Press MODE ESC in order to return to the main menu 2 Automatic Program Run e Select FruncMode Press ENTER to confirm Select AutoProg Press ENTER to confirm Select Master or Alone Press ENTER to confirm Press MODE ESC in order to return to the main menu 23 VOLT Q3 User Manual ver 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued 3 Program Selection for Auto Pro Part e Select EditProg Press ENTER to confirm Select Sel Prog Press ENTER to confirm e Select ProPartl ProPart2 or ProPart3 and select which Slave progra
26. placing or serving 9 VOLT G3 M User Manual ver 1 FIXTURE OVERVIEW www elationlighting com 10 11 12 13 14 LED Lens LCD Menu Display MODE ESC Button UP Button DOWN Button ENTER Button Charge Indicator Wireless DMX Indicator Power Switch Power IN DMX IN DMX OUT Wireless DMX Antenna Carrying Handle VOLT Q3 User Manual ver 1 www elationlighting com BATTERY CHARGING The VOLT G3 internal rechargable Lithium lon battery provides up to 6 hours of operation at FULL ON 100 intensity 837 Please note battery life will vary depending on fixture usage and settings install location temperature and number of charge cycies CHARGE TIME Unit must be connected to charger a period of 8 hours to fully charge the battery RECHARGING AFTER USE Connect the unit to the charger when the battery level reaches approximately 20 To check the battery life level access the Battlnfo menu on unit LCD menu display 11 VOLT Q3 User Manual ver 1 www elationlighting com FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5 0 ft 1 5m away from any flammable materials decorations pyrotechnics etc ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and or installations ISP CAUTIONS For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthor
27. s 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu DOCUMENT VERSION IJ Please check www elationlighting com for the latest revision update of this manual Document Software DW Dal Version Version Channel Modes Notes 2013 1 gt V1 0 4 5 7 9 Initial release 2 VOLT Q3 User Manual ver 1 www elationlighting com CONTENTS General Information 4 Warranty 7 Safety Instructions 8 General Guidelines 9 Fixture Overview 10 Battery Charging 1 Fixture Installation 12 Understanding DMX 15 Fixture Menu 18 Internal Wireless DMX Receiver Set Up 26 DMX Channel Functions And Values 28 Cleaning and Maintenance 30 Technical Specifications 31 Optional Accessories 33 3 VOLT Q3 User Manual ver 1 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable ArtNet to DMX converter on the market today The VOLT G3 has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance IP65 RATED An IP rated lighting fixture is one which is commonly installed in outdoor environ
28. s optics e Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt debris accumulation Never use alcohol solvents or ammonia based cleaners MAINTENANCE Regular inspections are recommended to insure proper function and extended life There are no user serviceable parts inside this fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every 3 months to make sure the circuit contacts are in good condition and prevent overheating e Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury e Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person s e Inspect all moving parts and make sure there are no signs of wear and rotate move without imbalances e Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 30 VOLT Q3 User Manual v
29. the 9 Channel Extended Mode You can chain multiple panels together through serial linking The data link cable included must be used Always be sure daisy chain your in and out data connections never split or Y your DMX connections y tun MEAN y T M 306 Ss 120 Ohms N DMX512 gt DMX controller Address 1 Address 10 Address 19 DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator will decrease the possibilities of erratic behavior pan T Termination reduces signal errors and avoids signal transmission problems Til and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX PN and PIN 3 DMX of the last fixture 16 VOLT Q3 User Manual ver 1 www elationlighting com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to
30. ty is void if the product serial number and or labels are altered or removed if the product is modified in any manner which Elation Professional concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional reserves the right to make changes in design and or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made w
Download Pdf Manuals
Related Search
Related Contents
Development of an Environment Framework for a Modular Vehicle Model 8370 AccuBalance Manual manuali d`officina werkstatt-handbücher workshop Gebruiksaanwijzing User Manual Mode d`emploi classement MT 2013 - Office de tourisme du pays de サプライ情報 Sunny Island - SMA Solar Technology AG JVC BR-DV6000E VCR User Manual Connection Guide Copyright © All rights reserved.