1. flag has to be set All these conditions are met right after installation by default so you are only required to customize the scripts for your personal needs The status_update script is invoked with three arguments status_update lt status gt lt battery_level gt lt time_left gt The status is either ON_LINE ON_BATTERY or UNKNOWN The battery_level is the current battery power level in percent 0 100 and time_left is the remaining time in seconds The other three scripts just receive battery_level and time_left as arguments on_battery lt battery_Level gt lt time_Left gt on_line lt battery_Level gt lt time_Left gt shutdown lt battery_level gt lt time_left gt 13 The sample scripts are passive since there are only comments inside By default BASH is used as script interpreter but you are free to use C Shell or Perl scripts as well every script interpreter installed on your system will be fine just alter the first line of the scripts accordingly Executing Apple Scripts e g MyAppleScript scpt is a special case since it has to be copied into the directory and then has to be in voked from within a shell script like this bin sh usr bin osascript MyAppleScript scpt 14 Chapter 4 Considerations and Feedback Every user feedback is helpful to further improve APC Tracker Client in the future We appreciate all kind of feedback positive comments negative comments bug reports or
2. questions are all equally welcome Only if we receive feedback we can realistically evaluate our performance So your feedback is important welcome and much appreciated
3. the APC Tracker Server icon to activate installation of the server and start up scripts Note Only adminstra tors are able to install the APC Tracker Server for which authorization will be re quested Setting up the Web SNMP Card If you d like to run APC Tracker in SNMP mode you have to change some settings of your Web SNMP card Open a browser and connect to your APC device In the screenshot below you see a typical welcome screen of an APC device Web SNMP Management Card www apecc com Smart UPS 2200 RM named equinux1 Smart UPS 2200 RM Describes the UPS status IP 192 168 40 51 On ee k Web SNMP Management Card AWON Describes the Management Card status System Name Unknown Date 02 23 2004 Logout Contact Unknown Time 16 44 46 3 30 Days 21 Hours Location Unknown UpTime 27 Minutes Status OK User Administrator Interactive Assistant APC Tracker DE APC Tracker EN equinux In the navigation menu to the left there s an entry named like the model of your device here Smart UPS 2200 RM Click on this menu entry to open a submenu In the submenu select the entry PowerChute Web SNMP Management Card IP 192 168 40 51 Smart UPS 2200 RM Diagnostics Control Configuration PowerChute The PowerChute configuration page looks like shown in the picture below Web SNMP Management Card IP 192 168 40 51 PowerChute network shutdown Configure th
4. Management Card built in SNMP Mode e anAPC UPS connected to a Linux PC running APCUPSd The equinux development team would be happy to receive your ideas comments and suggestions via email to apctracker equinux com System Requirements For set up APC Tracker requires both Mac OS X 10 2 or higher and the BSD subsys tem from the Mac OS X installation Contact amp Support Web site http www apctracker com Email apctracker equinux com Disclaimer You are testing this software at your own risk Although this software has been tested on our systems it is impossible to foresee possible problems that may ar rise when used on foreign systems or within foreign networks We can not be held responsible for any damages of any kind including without limitation loss of prof its loss or damage to data loss or damage to goods resulting from the use ofthis software You hereby agree that equinux USA Inc is not liable whatsoever for your use of this software You shall indemnify and hold equinux USA Inc harmless from any third party claims damages liabilities costs and fees including reasonable attorney fees arising from your use of the software as well as from your failure to comply with any terms of this agreement Chapter 2 Getting APC Tracker up and running Installation Drag and drop the APC Tracker Client icon from the disk image to your Applictions folder to install the APC Tracker Client Double click on
5. e event notification port and shutdown behavior settings UPS 2200 RM gare me Event Notification Port 3052 Diagnostics Shutdown Behavior Reboot On Line Return v Control Apply Cancel Configuration Configure the PowerChute clients registered to receive event notifications Events Add Client IP Address 192 168 40 255 Network Add Cancel System Logout Configured Client IP 192 168 40 255 4 Addresses 0 0 0 0 y 0 0 0 0 Help 0 0 0 0 0 A Interactive 0 0 0 0 OL Assistant 0 0 0 0 0 0 0 0 0 0 0 0 Links 0 0 0 0 APC Tracker DE 0 0 0 0 7 0 0 0 0 4 AP C Tracker EN 0 0 0 0 equinux Remove Cancel There are two important settings on this page The first one is the Event Notifica tion Port Usually you don t have to change it but if you changed it you also have to enter the same port number in APC Tracker when configuring the SNMP mode The second important setting is the client list Either add the addresses of all clients running APC Tracker Server to that list or add the broadcast address of a network segment all computers within the network segment are then included automati cally In the example above the broadcast address has been used Setting up APCUPSd If you d like to run APC Tracker in APCUPSd mode you have to activate the NIS mode within APCUPSd To activate the NIS mode it s enough to add the following two lines to etc apcupsd apcupsd and restart the daemon NETSERVER ON NISPORT 3551 Yo
6. e quinux d APC Tracker Version 4 4 User Manual Copyright 2001 2008 equinux AG and equinux USA Inc All rights reserved Contents Chapter 1 Welcome to APC Tracker Getting started What is APC Tracker System Requirements Contact amp Support Disclaimer Chapter 2 Getting APC Tracker upand running Installation Setting up the Web SNMP Card Setting up APCUPSd Setting up USB Chapter 3 Functionalities of APC Tracker APC Tracker Structure Shutdown Process APC Tracker Client Custom Scripts Support Chapter 4 Considerations and Feedback ann OR A A oO O O0 ON ON BW 12 14 Chapter 1 Welcome to APC Tracker This chapter introduces you to the all new APC Tracker a Cocoa application for UPS devices in a network that powers specifically off Mac OS X and Xserve Getting started Thank you for selecting APC Tracker Due to the complete rewrite of APC Tracker we would recommend that you read this manual thoroughly prior to installation What is APC Tracker The equinux APC Tracker is a client server application for UPS devices in a network running under Mac OS X and designed for server environments such as the Apple Xserve It can investigate the status of the UPS device and will properly shut down the client computer once power gets interrupted APC Tracker is currently able to connect to the following network device service e anAPC UPS with USB support USB Mode e anAPC UPS with an APC Network
7. ng down the system in one of two ways 1 Soft Shutdown 2 Hard Shutdown Soft Shutdown means that the server will perform the same action as if you were shutting down your system manually It will inform the Finder to shut the system down and be left to perform the task automatically It should be noted that this is not guaranteed work First of all it will fail if there is no user logged into the system system still shows login screen or if the system is in console mode logged in as user gt console The second restriction is that any open application might block the shutdown pro cess e g before closing an open text document the application questions if you really want to quit without saving Unless you click this dialog away the shutdown process is discontinued For such situations the Hard Shutdown will kick in You can determine the span of time for which APC Tracker Server will wait before switching from Soft to Hard Shut down or whether it should immediately perform a Hard Shutdown A Hard Shutdown is not as smooth running as a soft one but it will still ensure that all processes are interrupted and all data within caches written to disc before the system powers down All applications receive a signal asking them to be terminated at once and those that don t comply will be aborted with force It is inevitable that unsaved data in the memory other than cache will be lost but still to be favoured over
8. simply pull ing the power plug which is what happens if the APC runs out of power causing everything including all cached data to be lost possibly leaving the disc drives in a corrupted state and giving applications no chance to quit independently 11 APC Tracker Client The graphical user interface of the APC Tracker client should be pretty self explana tory once you have browsed through the menus and open windows When running the APC Tracker Client on the same Mac as the APC Tracker Server you could start for example by entering localhost without the quotes into the text field of the connect dialog which opens on every startup of the client and then clicking on Connect to see the status information of your APC device You can manage favorites to which you can assign names and personal icons mak ing it possible to automatically reestablish your favorite connections on restarting the APC Tracker Client Several tool tips will also appear to guide you through the user interface whenever you are unsure about the function of a particular item simply place your mouse over it and wait two seconds for annotation The toolbar above the status window allows you to open up the model or power drawer to receive more detailed information about the APC s current state To alter the configuration of the APC Tracker Server you are currently connected to e g altering the shutdown criteria click on Configuration Here
9. u may also choose a different NISPORT just remember this setting as you have to enter the port number within the APC Tracker configuration page for the APCUPSd mode Setting up USB USB supports plug and play that means there are no settings you have to change just plug in the USB device and select it from the list of offered devices on the USB configuration screen within APC Tracker Chapter 3 Functionalities of APC Tracker APC Tracker Structure The APC Tracker consists of two components 1 APC Tracker Server 2 APC Tracker Client APC Tracker Server is an application that runs facelessly in the background as a sys tem service It starts automatically at boot time permanently monitors the APC UPS device and remembers its last status Whenever a shutdown criterion is met e g battery level below a certain value it will try to shutdown the system on which it is currently running APC Tracker Client is an application with a graphical user interface It connects to APC Tracker Server and displays the current status of the APC It is further used to configure the APC Tracker Server e g in defining what the shutdown criteria actu ally are An APC Tracker Client can connect to multiple APC Tracker Servers simultaneously running on different Macs within a local or remote network It can also connect to a server running on the same machine as the client itself 10 Shutdown Process APC Tracker Server is capable of shutti
10. you will have the op tion of deciding if the APC Tracker Server runs in USB SNMP Card or APCUPSd mode on the connection tab In addition you can alter the configuration of the selected mode have a look at the Connection tab Configuration changes will take effect immediately upon saving After saving the configuration status will turn blank for a few seconds because a configuration update causes the APC Tracker Server to perform an internal status reset 12 Custom Scripts Support System administrators who are interested in running their own custom shell or Perl scripts now finally get a chance to do so If you don t want to run your own custom scripts just skip this section You will find a set of sample scripts to demonstrate how to use the new scripting support in the directory Library Application Support APC Tracker Scripts on the system where you installed the APC Tracker Server There are four scripts e status_update Executed once every minute with the current status as parameter e on_battery Executed whenever the APC detects a power failure and switches to battery mode e on_line Executed whenever the APC returns from battery mode once the power has been restored e shutdown Executed right before the APC Tracker Server decided to shutdown the system It is necessary that the scripts are stored in this location they also have to be named as shown above and they must be marked executable the executable