Home

ANALOGUE UNIT

image

Contents

1. for the receiver If the signal is too weak or too strong it turns the correspondent error light signal on When using an external PC together with the analogue unit the primary control for the PSMR is the analogue unit The PC can be connected to the analogue unit to read the measurement data for graphics display and data recording Analogue outputs X Y 0 5V USB RS Box PC USB RS port Controller 12 VDC IO connections RS 232 for the PSM R unit USB or RS 232 for the PC AO1 0 5 V X axis AO2 0 5 V Y axis Page 4 8 Analogue output unit for PSM R user s manual Led1 Error the measurement unit does not respond Cable not connected PC analogue unit switch in wrong position Low battery voltage Error in serial transmission Led2 No Object signal too low or too high No object in receiver sight Not enough reflecting power too long measuring distance Unclean or dirty reflector Too strong signal prism located too near Blinking led automatic power control running Measurement speed 1 meas speed 20 meas s 8 pulses filter 70 2 meas speed 50 meas s 6 pulses filter 54 3 meas speed 65 meas s 4 pulses filter 35 4 meas speed 100 meas s 2 pulses filter 1 6 Analogue output unit for PSM R user s manual Page 5 8 Limited Warranty The product has been thoroughly tested and inspected before shipment All parts excluding accumulators are warranted to be free
2. of defects in material and workmanship for one 1 year from the date of the shipment The Warranty is always subject to the concurrence of the following three conditions 1 No claims under this Warranty will be honoured unless notice of a defect affecting any specific item of Products is given to Noptel within the warranty period and 2 Any specific item of Products considered by the Buyer to be covered by this Warranty shall be returned at the Buyer s cost to Noptel Oy together with a copy of sale document showing the date of purchase within one 1 month from the day of notice as set out above and 3 Noptel Oy shall find such an item of Product returned to Noptel Oy as set forth above defective due to faulty workmanship or use of defective materials If Noptel Oy finds the Product to be defective Noptel Oy s liability under this Warranty is limited to repair or replacement of the Product free of charge Ex Works EXW Oulu Finland or credit for an amount equal to the invoiced value of the defective Product Vv Y VV WV When sensing a Product for the repair please attach an explanation of the defect to the shipment in order to expedite and facilitate service This Warranty excludes all consequential damages The Warranty will terminate if an unauthorised person opens the units during the warranty period This Warranty does not cover defects caused by misuse or improper handling installation or maintenance of
3. pulses 16 70 94 35 16 1 mrad 0 5V 0 5V Displacement from zero line mm distance m AO signal V 2 5 V 2 Calibration testing disconnect the optical unit turn power on speed 4 gt maximum signal in analogue outputs speed 3 gt middle signal in analogue outputs speed 2 gt minimum signal in analogue outputs Page 8 8 Analogue output unit for PSM R user s manual
4. Noptet ANALOGUE UNIT For PSM R M2 DISPLACEMENT SENSORS Noptel Oy 25 11 2010 Noptel Teknologiantie 2 FI 90590 Oulu Finland Tel 4358 40 181 4351 Fax 4358 8 556 4101 E mail info noptel fi Technical support see our Web site www noptel fi Page 2 8 Analogue output unit for PSM R user s manual Analogue output unit The analogue output unit is a stand alone micro controller based unit which communicates with the measurement unit via serial interface and at 19200 baud communication speed The unit is supplied by an external 12 VDC power supply The unit produces a voltage output 0 5 V scaled to 10 mrad angle in full scale The final position of the target can be calculated by multiplying the angle value by the distance between the measurement unit and the target 0 10V output is also possible on request The output scale of the unit is PSM R M2 1 mrad 0 5V 0 5V 5V 10 mrad 1 mrad 180 1 1000 0 05729577951 1 mrad 10mm 10m Displacement from zero line mm distance m AO signal V 2 5 V 2 Analogue output unit for PSM R user s manual Page 3 8 Example 1 At 120 m distance the analogue output value is 3 5 V The displacement 120 3 5 2 5 2 2 240 mm Example 2 At 10 m distance the analogue output value is 1 0 V The displacement 10 1 0 2 5 2 30 mm The measurement unit automatically controls the transmitter optical power to produce the best signal
5. the products Always follow the rules and hints for the proper handling and maintenance given by the manufacturer The units contain no user serviceable parts Manufacturer or dealer is not liable for damages caused by erroneous measurements or inadequate treatment Disposal Do not dispose this product as unsorted municipal waste In the European Union all electrical and electronic products batteries and accumulators must be taken to separate collection at the end of their working life Page 6 8 Analogue output unit for PSM R user s manual Analogue output unit Short form guide HS 232 cable for the USB RS Box and PC Power supply Red 12 V Black Gnd Control switch sensor control from the PC Analogue unit sensor control from the analogue unit Power ON OFF RS 232 connector for the Optical unit cable 19200 Bd Led1 for error in operation with the sensor Cable not connected or B 2 d PC analogue switch wrong ed for target identification and signal power control No object in receiver sight Too much or too little reflection signal Error in operation position or Low battery voltage Serial communication error blinking gt power control in operation Analogue output unit for PSM R user s manual Page 7 8 AO2 opeed control switch 0 5 V 1 50 ms filter 8 pulses Y axis 2 20ms filter 6 pulses 3 15ms filter 4 pulses 70 54 35 4 10 ms filter 2

Download Pdf Manuals

image

Related Search

Related Contents

Ver1.573 対応 - Anshu(Software ANNEX)-touch-jw  direito constitucional, administrativo, tributário e comercial  LG LSRC 26912TT User's Manual  Electrolux EJN2710AOW fridge-freezer  HVR-M25E  平成 24年(ワ)第 14652号      Sony CECH-4001B User's Manual  MC-435 DMT PIR intrusion detector user manual  

Copyright © All rights reserved.
Failed to retrieve file