Home
Precision Pipeline Locator System User Guide
Contents
1. Disconnect other Rectifier lt gt PCM Transmitter to Pipeline Connections Using Cathodic Protection CP Rectifier 1 Single rectifier providing impressed CP current to single pipeline Rectifier is connected to anode and pipeline Power supply from 110 230V AC mains Disconnect pipeline and anode cables from the rectifier terminals Failure to disconnect cables from rectifier will cause unstable PCM signals and may cause damage to the PCM transmitter Connect PCM transmitter to the cables white lead to pipeline cable green lead to anode cable Use the mains power supply for the transmitter If isolation joints are not used PCM signal will be present in both directions from the connection point 2 Single rectifier providing impressed CP current to multiple pipelines Disconnect pipeline and anode cables from rectifier Try to identify individual pipeline cables if they can be separated at the rectifier so that each pipeline can be surveyed individually Use the PPL receiver to help identify the cables to the individual pipelines Connect the PCM transmitter white connection lead to one of the pipeline cables and the green connection lead to the anode cable use the PPL receiver to help identify the cables to the individual pipelines If the PCM transmitter signal is applied to more than one pipeline at a time the signal will be divided between them so the maximum range will be reduced
2. Note The pipe section that needs the most cathodic protection will also have the most PCM current Using the PPL receiver to measure the current on all the pipe sections fed from the rectifier will indicate the section with the worst CP faults This is a quick and easy guide to coating quality Page 13 Wire Link Test Point Insulating Joint Remove Link or Shunt Insulating Joint Wire Link or Shunt Test Point Sacrificial Remove Link or Shunt Test Point Sacrificial Insulating Page 14 PCM Transmitter to Pipeline Connections When Rectifier is not Available Test Points At some test points there are Isolation Joints with cables to the surface Connect the PCM transmitter across the isolation joint Connect white cable to the side of the pipeline that you want to survey and the green cable to the other side for ground Note Make sure that the pipes run in opposite directions If your connections are on pipes in the same direction this may affect the survey results Sacrificial Anodes Sacrificial anodes can be used as a grounding point for the PCM transmitter This type of connection can be used when there are no isolation joints Disconnect the link wire from pipeline to sacrificial anode in the test point Connect the white cable from the PCM transmitter to the pipeline connection and the green cable from the PCM transmitter to the anode Note If the anode is heavil
3. Radiodetection products are under continuous development and are subject to change without notice All rights reserved 90 UG052ENO
4. manufacturer s instructions and your local regulations When the low battery warning is displayed on the LCD it is necessary to replace the batteries The batteries 4 D cells are located in the housing at the rear of the carrying handle see illustration Before using the receiver ensure that a set of charged batteries is installed and correctly fitted Note Always replace batteries as a set To replace batteries proceed as follows e Release battery housing cover by means of the release catch situated under the carrying handle e Remove batteries e Insert new batteries ensuring that they are installed correctly as indicated on the label within the battery housing e Close battery housing cover PPL Receiver Operation On Off Press and hold the On Off key for one second The software revision number will be displayed for two seconds and the speaker will emit a tone The PPL receiver will then show the Define Pipe Diameter screen Precision Pipeline Locator System User Guide Define Pipe Diameter Screen The diameter may be entered in either metric or Imperial units Selection is made through the system menu The screen display shows the following Increment Decrement Coarse Increment or Fine Increment Accept Define Pipe Diameter Pipe diameter can be adjusted by pressing the Increment or Decrement key or by turning the gain paddle anti clockwise When using the gain paddle the displayed diameter is
5. provide the following options Upload Data Log Download S W Upgrade Restore System Defaults and Self Test Note Before connecting the PPL receiver to a PC or Laptop PC the following precautions must be taken e To reduce the effect of static electricity wipe the PPL receiver with a damp cloth e Wear an earthed wrist strap Upload Data Log The Upload Data Log option allows the contents of the PPL Data Log to be uploaded to a PC e Connect the PPL receiver to the PC using an RS232 cable e Press the Start menu key to initiate data transfer The Uploading Data Log progress bar is displayed e Press the Cancel menu key or the Exit key to return to the System Utilities menu screen without performing an upload If necessary press the Abort menu key to terminate the download Upload Aborted is displayed for five seconds unless a key is pressed or the gain control is operated After the Data Log is uploaded to the PC Upload Successful Press any key is displayed The Data Log is never deleted the most recent entry overwrites the oldest If the Upload cannot be completed for any reason ERROR and Upload Failed Press any key is displayed Page 5 Precision Pipeline Locator System User Guide Software Upgrade scan Connect the R5232 cable and press the Start menu key DOWNLOADING NEW SOFTWARE DO WOT SWITCH OFF 26 904 COMPLETE DOWNLOAD FAILURE RESTART SOFTHARE TRANSFER
6. AND PRESS ANY KEY WAITING FOR SOFTWARE CONNECT RS232 CABLE AND START SOFTHARE TRANSFER Page 6 Download Software Upgrade The Download Software Upgrade option allows new PPL software to be downloaded from a PC Note Before connecting the PPL receiver to a PC or Laptop PC the following precautions must be taken e To reduce the effect of static electricity wipe the PPL receiver with a damp cloth e Wearan earthed wrist strap To download new software proceed as follows e Connect the PPL receiver to the PC using an RS232 cable e Press the Cancel menu key or the Exit key to return to the System Utilities menu screen without performing a download e Press the Start menu key to initiate data transfer During the download DOWNLOADING NEW SOFTWARE DO NOT SWITCH OFF and the data transfer percentage completed is displayed If the download completes successfully the PPL will reboot with the new software If the download fails for any reason DOWNLOAD FAILURE RESTART SOFTWARE TRANSFER AND PRESS ANY KEY is displayed If the PPL is switched on when there is no valid software installed WAITING FOR SOFTWARE CONNECT RS232 CABLE AND START SOFTWARE TRANSFER is displayed Precision Pipeline Locator System User Guide Confirm Restore Confirm Restore Confirm You want to restore all settings Lo their default value System defaults restored Press any key ntenna amplifiers PAS
7. Switch to a lower current setting until the GREEN Output OK LED comes on Allow a few seconds to settle between selections Voltage Limit LED Transmitter is at 100V output voltage limit The pipe or ground connection resistance is too high Check all connections Page 11 OUTPUT BOTH LEADS HAZARDOUS LIVE o REFER TO L USER MANUAL Page 12 White To Pipe Green To Ground Signal Connection A Warning Pipeline Company safety procedures must be followed before removing pipeline Cathodic Protection CP connection A Warning Whenever handling transmitter connection leads always ensure that the transmitter is switched OFF Disconnect pipe and anode cables from the rectifier Connect the white signal output lead to the pipe cable Connect the green signal output lead to a suitable anode cable Note If connections are reversed the current direction arrow on the PCM receiver will point in the wrong direction Use an isolated low resistance ground such as a sacrificial magnesium anode or anode for the pipe to be located When connecting to an electrical isolation joint the other pipe section can often provide a suitable ground connection Care must be taken when using an earth stake as the resistance is often not low enough The stake must be positioned at least 45 M 150 feet from the pipe to ensure an even current distribution Mains Supply Rectifier Disconnected Mains Supply
8. adjustable between O and 2 99 M when using metric measurement and 4 and 9 4 when using Imperial Pressing the Accept key takes the display into Pipeline Locate Mode Pipeline Locate Mode The Pipeline Locate screen displays the following Bar Graph Received signal strength Peak or Null Selected gain Cable Orientation Indicator Left Right arrows Null only Pipe diameter Selected frequency Peak Null indication Battery level indication five levels Speaker Volume four levels including Off Date Time and Time Zone The Pipe Locate operating controls are as follows e Peak Null key Toggles between Peak and Null modes and indicates the selection on the LCD Depth Current key Simultaneously displays pipe depth to the centre of the target and signal current for five seconds Freq Mode key Cycles through the receiver operating frequencies of ELF LF 8 kHz and Power actual frequencies depend on country amp Radiodetection Page 3 Page 4 Precision Pipeline Locator System User Guide e Gain Control Paddle If the signal strength is at maximum or less than 10 a momentary flick of the control in the appropriate direction will cause the gain to be adjusted to give an approximate bar graph indication of 50 If the signal strength is below maximum and greater than 10 the control will adjust the gain in 1dB steps with each momentary flick or by rapid stepping if the
9. control is held when rotated Display Contrast While the receiver is switched off press and hold the On Off key After a few seconds the contrast automatically cycles through its range Release the On Off key when a satisfactory display contrast is achieved Refer to the Contrast screen in the System Setup menu for routine adjustments Menus The top level menu screen displays the following options System Menu Pipe Diameter e Cable Locate To select an on screen option press the adjacent Menu key situated to the left of the LCD display System menu options are displayed as follows Volume Contrast Backlight Clock System Setup Upload Download Defaults Test System Utilities User Preferences PPL Information Options are Volume Off Low Med High Contrast On screen slider adjusted by Lighter Darker keys or Gain Control Backlight Off On Auto Clock Daylight Saving Time Zone Time Format Time Date Upload Data Log Start Cancel Download S W Upgrade Start Cancel Restore System Defaults Confirm Restore Cancel Self Test Automated tests and results Precision Pipeline Locator System User Guide Upload Data Log Connect the RS232 cable and press the Start menu key Upload Data Log Uploading Data Log Upload Successful Press any key System Utilities System Utilities are found in the System Menu and
10. displays the following options Measurement Units Depth Current Idle Timer Switch Off 5 10 15 30 60 Minutes or Continuous Auto gain Enabled Disabled Feature Configuration Note this feature is for Radiodetection use only PPL Information Screen The PPL Information screen displays the following information Version Status Build Version No Build No Build Date Build Time Statistics Data Log used Total Operating Time Last Calibration Date Shipped Review A C ID Data Confirmation Mode The Confirmation mode screens display the following options PPL Bar PPL screen prompts for the green button to be pressed Direct Selection Direct Selection allows quick selection of any menu item from a list without having to use the menu structure Press and hold the Exit key for one second to display the Direct Selection screen Select the function required by rotating the Gain Control to move the highlight bar down clockwise or up anti clockwise then access that function by pressing the Exit key lt Precision Pipeline Locator System User Guide Mains Supply PCM Transmitter Functions Opening and Closing Transmitter Lid The PCM transmitter is contained in a rugged waterproof case which is opened by applying a slight pressure to the case lid just above the clips The clips will then open freely In certain situations the air pressure within the case ma
11. locator when wearing steel toe capped boots may also affect the readings Precision Pipeline Locator System User Guide Introduction The Precision Pipeline Locator PPL system is used to locate pipes and calculate the depth of cover Note The depth of cover is the depth from the surface to the top of the target pipe The system comprises the following equipment PPL Receiver PPL Bar Pipeline Current Mapper PCM transmitter Optional Hand Held Data Viewer Palm Vx PPL Receiver The PPL receiver is a portable battery operated handheld device Information is displayed on a Liquid Crystal Display LCD A built in speaker gives audio signals during receiver operation PPL Bar When placed on the ground over the target pipe and activated the PPL Bar receives the applied signal from the PCM transmitter and relays this information to the PPL receiver via a short wave radio link Note The direction arrow on the bar must point towards the transmitter PCM Transmitter The portable PCM transmitter is used to assist in pipeline location by applying the required signal to the target pipe Page 1 Page 2 Precision Pipeline Locator System User Guide PPL Receiver Features Receiver Battery Replacement A Warning Do not mutilate puncture or dispose of batteries by placing them ina fire The batteries can burst or explode releasing hazardous chemicals Discard used batteries in accordance with the
12. 0 mA Ne PEMETX Radi 100 mA 3 e Serial No C Output OK Over Temerature Power Limit Output Current A o o o Output Voltage Level Voltage Limit 600 mA 1A 2A Output Level Page 10 Turn the six position Current Select switch to the minimum position and switch on the PCM transmitter Progressively increase current output to obtain a setting that does not overload the input Maximum output power is dependent upon voltage For example on a particular pipe an input voltage of 20V may only allow a maximum output of 300mA whereas an input voltage of 50V may allow an output of 3A The transmitter dc input is protected against reverse polarity and over voltage and will not operate unless connected correctly Frequency Select The three position rotary switch selects the applied mapping frequencies as follows TRANSMISSION LINES ELF maximum range 35 4 Hz 65 ELF 128 Hz or 98 Hz Note this selection is not for use with the PPL system TRANSMISSION AND DISTRIBUTION LINES ELF current direction medium range 35 4 Hz e 30 8 Hz current direction e 35 ELF 128 Hz or 98 Hz DISTRIBUTION LINES LF current direction alternative frequency 35 4 Hz e 30 8 Hz current direction 35 LF 640 Hz or 512 Hz The 4 Hz mapping frequency is always present and the operator has a choice of selecting the locate frequency and direction indication if r
13. Precision Pipeline Locator System User Guide Rev 0 04 2001 ea i Radiodetection Precision Pipeline Locator System User Guide Precision Pipeline Locator System User Guide TABLE OF CONTENTS Title SAFETY NOTES lt Precision Pipeline Locator System User Guide A Safety Notes The above safety alert symbol is used throughout this User Guide to highlight critical information Read this information carefully and follow any instructions that may be given Radio Interference This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense A Warning The operation of any cable and pipe locator may be affected when used in close proximity to ferrous materials such as manhole covers and parked cars Keep a one or two metre distance from these objects when taking critical measurements such as depth and current readings Standing too close to the
14. S SP FPGA PASS AM PASS EROM eal Time Clock Software integrity Data file integrity Calibration Data integrity Extension Port Performing Self Test Weelo _ o ymy 4d4d1 4t i2k4 lt 4 Z424 lt Antenna amplifiers EROM eal Time Clock Software integrity Data file integrity alibration Data integrity xLension Port not in use Ho Faults Found PASS Press any key Restore System Defaults The Restore System Defaults option allows the configuration of the PPL to be set to pre defined defaults e Press the Confirm Restore menu key to confirm and initiate the request e Press the Cancel menu key or the Exit key to return to the System Utilities menu screen without restoring defaults After the defaults are restored System defaults restored is displayed for five seconds unless any key is pressed or the gain control is operated and the receiver enters the operating mode last used Self Test To initiate a Self Test select it from the System Utilities menu During the Self Test a list of the automated tests performed and their results are displayed The Performing Self Test progress bar is displayed On completion of the automated Self Test a Pass or Fail screen is displayed with the prompt Press any key Pressing any key returns the display to the System Utilities menu Page 7 Page 8 Precision Pipeline Locator System User Guide User Preferences Screen The User Preferences screen
15. Successful confirmation cannot be achieved until the tilt angle is reduced to less than 45 If the PPL Bar is tilted but at an angle of less than 45 the screen will be similar to that shown opposite D 5 CO LA 2 c3 lt If the PPL Bar is not receiving a signal the PDL 4 screen will be similar to that shown opposite Lack of current could be caused for example by a poor connection or bad earth Tracing Procedure Tracing the pipe between confirmation locations is carried out using the PPL receiver Peak and Null modes Peak Rotate the PPL receiver until the orientation line in the centre of the Pipe Orientation Indicator is aligned with the North South marks Whilst moving the PPL receiver steadily from side to side follow the line of maximum response keeping the blade vertical and maintaining Pipe Orientation Indicator alignment Null If required press the Peak Null key to select Null mode and follow the path of the target pipe Minimum response with an increased response on each side indicates the position of the target pipe Press the Peak Null key again to return to Peak mode Page 19 Radiodetection Ltd Western Drive Bristol BS14 OAZ UK Tel 44 0 117 976 7776 Fax 44 0 117 976 7775 email sales uk radiodetection com http www radiodetection com Ca Radiodetection
16. e provided every inch as a guide to the exact location of the pipe Battery Replacement There are two battery compartments located under separate grey covers one at each end of the PPL Bar Each compartment contains 2 D cells Before using the PPL Bar ensure that a set of charged batteries is installed and correctly fitted Warning A Do not mutilate puncture or dispose of batteries by placing them ina fire The batteries can burst or explode releasing hazardous chemicals Discard used batteries in accordance with the manufacturer s instructions and your local regulations Note Always replace batteries as a set To replace batteries proceed as follows e Release the quarter turn fasteners to remove the battery housing covers e Remove batteries e Insert new batteries ensuring that they are installed correctly as indicated on the diagram within the battery housing e Close battery housing covers The battery compartment at the green button end of the PPL Bar also houses an RS232 socket for software download Locate Procedure Ensure the transmitter is set to ELF mode with CD arrows and is energising the correct pipe Ensure that the PPL receiver is in Peak mode before taking measurements Locate the target pipe in Peak mode then check using Null mode Depth Current Rest the end of the PPL receiver blade on the ground over the locate position centre the level bubble and then press the Depth Cur
17. equired for identification in congested areas and for fault finding Current Select The six position Current Select rotary switch selects the following rms 4 Hz current settings 100 mA 300 mA 600 mA 1A 2A 3A When the PCM Transmitter is in operation the current will remain constant at the pre set level unless input power supply limit is reached Precision Pipeline Locator System User Guide Warning Lights and Output Indication Output is voltage indicated by yellow output voltage level LED s PCMr IK Radlic LED indications are as follows Serial No C Output Ok No LED s lit voltage is below 20V e Raa 20V LED lit applied voltage between 20 40V Sean even d nail 40V LED lit applied voltage between 40 60V L output Vottage Level gt 60V LED lit applied voltage between 60 80V 80V LED lit applied voltage between 80 100V 600 mA 1A som 2p The 3 digit LCD displays the 4 Hz signal current in ar 8A amps that is being delivered onto the pipe Transmitter status indicated by the following LEDs S dii GREEN Output OK RED Over Temperature RED Power Limit RED Voltage Limit If a red LED illuminates the following actions should be taken Over Temperature LED Turn transmitter off and allow it to cool Power Limit LED External power supply not capable of supplying the demanded power to support transmission at the selected current The transmitter has reached its own power limit
18. rent key to display the target pipe depth and applied current Note In this mode the PPL receiver displays depth to the centre of the pipe and not the depth of cover Place the PPL bar over the point located by the PPL receiver and press the green button on the PPL bar The PPL receiver will pick up the PPL bar signal automatically The LCD will display that the bar is looking for the pipe signal Note In this mode depth of cover is calculated Once the PPL bar has located the pipe the locate information will be displayed on the PPL receive display similar to that shown opposite If the PPL bar ha not been placed above the target pipe the Reposition the PPL Bar screen will be displayed indicating the distance and direction that the PPL Bar must be moved Page 17 un A Ft g Cable x Out of Range x Flan View Rotate Counter Clockwise and press the green button Tilt angle too great x 45 maximum Page 18 If the PPL Bar has been placed too far away from the target pipe the Pipe out of Range screen will be displayed indicating direction and approximate position of the pipe If the PPL Bar is not correctly aligned at 90 to the target pipe a Plan View screen is displayed indicating the direction in which the PPL Bar should be rotated If the PPL Bar is tilted at an angle of more than 45 the Tilt angle too great 45 maximum screen is displayed
19. y depleted it will have high resistance and the PCM transmitter signal lights will indicate higher voltage In this case it is advisable to use a series of long ground stakes to provide low resistance grounding for the PCM transmitter Pipe to be Surveyed Whatever grounding is used for the PCM transmitter it should have resistance of less than 20 ohms to ensure good current output from the transmitter Using another pipeline as a ground for the PCM transmitter is an effective way of applying the signal Note Make sure that the other pipeline runs in a different direction from the pipeline to be surveyed Streams drainage ditches dikes marshes or any mass of water can be used to ground the transmitter Connect the green lead to any large metal object and submerge it in the water Note Ensure that the pipeline is not running through the same wet area Other electrical fixtures can be used to ground the PCM transmitter However this will cause all electrical cables in the area to carry the PCM transmitter signal If these cables run near the pipeline they may affect the survey results Page 15 Page 16 PPL Bar Features Current Direction When placing the PPL bar on the ground ensure that the direction arrow points towards the transmitter Green Button Press and release to operate the PPL Bar the adjacent LED will illuminate Location Graduations Graduations ar
20. y need to be equalised by turning the small knob located by the handle anti clockwise The case lid must remain open during transmitter operation to allow the heat sink to cool When closing the case lid ensure the connection cables are kept away from the heat sink and the support strut PCM Transmitter Power Supply Connections A Warning The equipment must be earthed through the PCM transmitter mains plug Switch transmitter OFF before connecting to either 230V 110 V AC supply or generator e 20 50V DC source e 15 35V rectified source 230 V 110 V AC Supply or Generator The transmitter is rated at 300W at 230V AC 50Hz 110V AC 60 Hz which provides the transmitter with enough power to operate at its maximum output capacity DC Supply This allows the PCM transmitter to be powered from 2 X 12V or 1 X 24V auto batteries or the output from the rectifier to the pipe and anode 20 50V DC and 15 35V rectified AC supply The input voltage range is 20 50V DC 14 35V rectified AC The current drawn from the supply will be a maximum of 5A Ensure that the rectifier is switched off Connect the black lead to the negative supply and the red lead to the positive supply Note If the supply cannot provide 5A this will be indicated by the power limit warning light Page 9 Precision Pipeline Locator System User Guide PCMETs Radi Serial No C ELF ELF 4 2 Frequency Select 30