1. 2300 3000 VER 101 WIDE INDICATOR USER S MANUAL www tmteng com Introduction Main Features Technical Specifications Description of Panels and Symbols Installation General Function Test Mode Setting Mode 9 Calibration 10 Infrared Remote Controller 11 Wireless Specifications 12 RS232C Format 13 Real Time Clock 14 Check Message 1 Introduction This Service and Operation Manual are the specifications for our Tl series The Tl series is the product of years of design development and in field testing This Tl series has been designed with reliability under rigid quality control and with outstanding performance This MANUAL included with basic technical information about composition of hardware and programmatic functions Precautions Please be informed that we re not responsible for any incident or mishap caused by partial modification of this product To avoid such situation customers need to contact our customer service team or system installation staff in advance and any modification should be conducted under our surveillance Do not connect incompatible adaptor Use only adaptor approved by TMT for use with this particular model The use of any other types may invalidate any approval or warranty and may be dangerous For availability of approved enhancements please check with your dealer 4 Dont install the series in direct sunlight Avoid sudden temperature changes vi
2. F15 1 Send data command key Print format F15 2 Send data command key 18bytes format F16 Auto transmit at data hold 0 1 The hold data will be sent by according to set in FO8 F17 Stream mode 0 2 16 F18 Setting low limit not included weighing points 200 20 0kg In case of one decimal point Select a digit place to be inputted with ZERO KEY Input a figure with HOLD KEY Press TARE KEY to enter the value F19 Setting high limit not included weighing points 500 50 0kg In case of one decimal point Select a digit place to be inputted with ZERO KEY Input a figure with HOLD KEY Press TARE KEY to enter the value 17 9 Calibration Press the ON KEY to power on and immediately press HOLDE KEY until is displayed and press ZERO KEY And then E AL is displayed and press TARE KEY to enter calibration mode Title Operation Description Show version gt He LS SOs LS lt Maximum capacity increment of input value increment of digit shift next menu Minimum division increase 29 decrease shift next menu Balance weight increment of input value L E E F increment of digit shift next menu It is recommendable to calibrate using a balance weight which weights 50 of the maximum capacity or more in terms of linearity Zero calibration Check unload the tray L LI Ll press 277 key Span calibration
3. Load the weight which was set in point 4 and press 217 key Calibration finish Unload the tray and press 21 key 18 10 Infrared Remote Controller 1 How to use mg OFF KEY Use to power on off the series mg ZERO KEY Same as keyboard of TI series m TARE KEY Same as keyboard of series m HOLD KEY Same as keyboard of TI series KEY CLEAR Refer to F09 m SUM KEY Use to add weights If press a SUM KEY the sum of weights is displayed After that about 2 sec later a weighing mode is reverted Weight of less than 5 digits is not summed Maximum of sum weights is 99999 and if it exceeds the weights is initialized to 0 2 Specification Power 3V 1 5V 2pcs 19 11 Wireless Specifications RF frequency range 2400 2483 5 MHz Output power Max 4dBm Channel width 2 MHz Frequency offset lt 30ppm Transmit data rate 250Kbps 500Kbps Receiver sensitivity 99dBm PER lt 1 Maximum input level OdBm RF In out impedance 50 ohm TXRF RXRF Spurious 2nd harmonics lt 30dBm Radio link effective range Approx 100M Open space 20 12 RS232C Format 1 Type EIA RS 232C 2 Method Full duplex asynchronous transmission Format 1 Baud rate 9600 bps 2 Data bit 8 Stop bit 1 Parity bit None 3 Code ASCII 3 Format 18byte Lam Start Code Weighing d
4. Zero Return the display to 0 Use to weigh with tare weight Hold Use to weigh unstable things 5 Installation 7 gt j J V U lt 4 5 0 gt GND OUTPUT KEY INPUT LOADCELL RX3 1 S gt GND Power adaptor RED Power adaptor BLACK Extra RS232C TXD Extra RS232C RXD Extra RS232C GND 0000 RS232C TXD 01 RS232C RXD OP 01 RS232C GND OP 01 Load cell EXC External key 4 contact 4inputs OP 01 2 solid state relays contact OP 01 1 External input circuit SWITCH TR x External inputs are interlocked with the touch keys 2 Solid state relay circuit 12 28VDC OUT1 OUT2 EVCC range DC12 28V R ibaa range gt 2 Output conditions 6 General Function 1 Zero Function Use to correct drifted zero value when the scale is unloaded and motion 15 not detected This function works when ZERO KEY is pressed and the ZERO LAMP is on 2 Setting Tare Weight Function Press the TARE KEY Then the scale will memorize the weight of the tare and will display zero value O kg The TARE LAMP will be on To escape this function remove everything from the scale and press the TARE KEY Then the TARE LAMP will be off and this function is terminated Note The sum weight of the tare and any item on a scale cannot exc
5. ata Stop code Status X Start code ST Stable US Unstable Lamp status byte One Two Three Decimal Decimal Decimal Stable Zero Tare Hold Place Place Place x Weighing data 8byte TOD ana 2195 Lo 5 x CR 0x0D LF 21 13 Real Time Clock 1 How to enter this mode Press the ON KEY to power on and immediately press HOLD KEY And press the KEY again 2 Keyboard gt O9 Used to increase the setting constant one by one gt HS Used to move the input value to the left or right by one place 9 Used to save the value and to move next menu Modify the year Modify the date Modify the time mes 22 14 Check Message m 1 Data in an internal storage allocation are erased owing to any electronic impact Please contact us to resolve this technical problem Something wrong in a Load cell connection or in an serial connection Please contact us to resolve this technical problem Fu LA Lli_i Load cell output is too small large at SPAN calibration Setting of current resolution is not possible due to the error in load cell Proceed calibration again with less resolution TL I 1 The weight for span calibration is set to be exceeded 10 100 of the maximum capacity of the scale Set the weight for span calibration CAL3 to be within the 10 100 of the maximum capaci
6. bration wind water or dirt Avoid from the shock of excessive weight 4 Place the scale away from water 4 Use away from heavy noise 4 Do not disassemble or modify this product 2 Main Features High precision indicator Water proof 65 Touch key Standard remote control 4 Tilt and swivel mount bracket 3 Technical Specifications 4 Specifications Display 2300 2 3inch 5 FND 3000 3inch 5 FND Display lamp Zero Tare Hold Stable Power Touch key Zero Tare Hold On Off Case material Engineering plastic Load Cell Excitation DC 5V 00 to 8 load cell Input sensitivity 0 2uV D Input signal range 0 39mV Non linearity lt 0 0015 of FSR max External resolution Up to 100 000 counts Output data rate 4 7 to 200 measurements per second Temperature range 20 C 60 C Product weight 2300 1 2kg 3000 2 2kg Power 12V 1A Parts Power adaptor IR remote controller RS232C RTC Real time clock 2solid state relays and 4inputs OP 02 Use the vehicle power 12 24V OP 03 ZigBee wireless OP 01 Dimensions 1 2300 gt ga i Tl 7 kodn H E oS E U kg o Hh 4 Description of Panels and Symbols 4 Display 8 0 0 0 Displays weight or messages ak 9 Power Use to turn on off
7. der half graduation for F03 5 2 5 sec Recognized as stable for change under half graduation for 4 5 13 04 Assignment of Automatic zero calibration 0 99 F4 00 Automatic zero calibration is not carried out for 3 sec for 9 sec 05 Assignment of Hold speed 1 9 06 Auto hold function 0 1 F07 Initialization of hold value 1 9 FO7 1 In the zero weight FO7 5 In the 5 division weight 07 9 In the 9 division weight F08 PC Printer connection 0 2 14 F09 Function key of remote controller 0 2 FO9 0 Operation is equal to the key of the master 09 1 Send data command key Print format 09 2 Send data command key 18bytes format F10 Hold key function 0 1 F10 0 Hold key F10 1 key Remote controller F11 Item number Identification number of each Item 0 9 Settings F11 0 Item No 0 0x01 F11 5 Item No 5 0x05 F11 9 Item No 9 0x09 F12 Print line feed 0 9 F13 Print form 0 2 Settings F13 0 Form 0 weigh No Item No weight F13 1 Form 1 Serial No Item No weight When the F09 1 is selected this form is printed The weigh No is not saved 15 0 1 2013 10 13 12 00 2013 10 13 12 00 001 ID_9 25 kg SN_02 ID_9 25 kg F14 Initialization of serial number 0 1 Settings F14 0 Maintain current number F14 1 Initialization starting from No 1 F15 Auto transmit at stable 0 2
8. eed maximum capacity 3 Hold Function Automatic Hold Function This function works whenever the scale weighs moving things Press HOLD KEY when the scale is empty Initial Zero State m The weight display will indicate Hh gn HOLD LAMP is on m After loading a thing if the weight turns stable then a display shows and average weight will appear The weight of a loaded thing is displayed To escape the automatic hold mode when zero point is on press HOLD KEY Then the message of HhaF F is displayed and HOLD LAMP is off and normal weighing mode is reverted Manual Hold Function Only this function operates when you press a HOLD KEY Press HOLD KEY loading a thing m This message of hal g is displayed and sequentially the message of is shown with appearing the average weight The weight of a loaded thing is displayed To escape the manual hold mode remove everything from a hook or press the HOLD KEY Then HOLD LAMP will be off and the scale changes from a hold mode to a normal mode 10 7 Test Mode 1 How to enter this mode Press the ON KEY to power on and immediately press ZERO KEY to enter test mode 2 Testing Menu TEST 1 TEST4 TEST 1 Keyboard Test Press a keyboard that you want to test and then the display message will be shown If press a TARE KEY move on TEST 2 Remote Control ZERO TARE SH9 HOLD TEST 2 Display T
9. est ODOO TEST 2 runs off automatically and a display is on LOL OL OL LI If press the TARE KEY move on TEST 3 TEST 3 Load Cell Test The value is the conversion constant for A D converter The value may be different according to scale s condition Check whether digital value is changing If the digital value is fixed or 0 please check the connection of load cell If press the TARE KEY move on TEST 4 11 TEST 4 Solid state relay output test ZERO KEY All outputs are turned off HOLD KEY Increase the output number 4 this output is turned on If press the TARE KEY move on weighing mode 12 8 Setting Mode 1 How to enter this mode Press the ON KEY to power on and immediately press TARE KEY to enter setting mode 2 Keyboard mg ZERO KEY Use to set up an initial zero value 0 F4 F18 F19 Used to move the input value to the left or right by one place mg HOLD KEY Use to add a value of 1 from existing value KEY Use to save an inputting value and to move on next menu 3 Menus F01 Assignment of weight variation rate 1 9 Settings Meaning F01 1 Indicating rate of weight is fast F01 5 Indicating rate of weight is moderate F01 9 Indicating rate of weight is very slow F02 Weight backup 0 1 F03 Assignment of Stabilization speed 1 9 F03 1 Recognized as stable for change under half graduation for 0 5 sec Recognized as stable for change un
10. ty When a thing is over weighed within the maximum weight value the error message is displayed Do not weigh the thing whose the limit of a maximum weight value is exceeded If a load cell is broken then the load cell has to be replaced 23 24