KLET200 - Hamer Limited

image

Contents

1. DC Voltage Measurement Continuity Testing Continuity is indicated at less than 270kQ of resistance o lt i oag 11 WARRANTY This product is warranted to be free from defects in materials and workmanship for a period of two years from the date of purchase During this warranty period Klein Tools has the option to repair or replace or refund the purchase price of any unit which fails to conform to this warranty under normal use and service This warranty does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse abuse neglect or improper maintenance Batteries and damage resulting from failed batteries are not covered by warranty A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Any implied warranties including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty Klein Tools shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss Some states or countries laws vary so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state If your Klein product requires repair
2. Instruction CN Manual ET200 Instruction Manual GENERAL SPECIFICATIONS The Klein Tools ET200 is a solid state electrical tester It measures AC DC voltage tests continuity and features a bright LED worklight e Voltage Level Indicators 12 24 48 120 208 240 277 480 600 e Voltage Type Indicators AC DC Positive DC Negative e AC Frequency 45Hz to 66Hz e Maximum Voltage To Earth Ground 600V RMS e Maximum Measurable Voltage 600V RMS displayed by LEDs Input Impedance 15kQ on connection up to 150kQ steady state Continuity lt 270kQ Usage Duty Cycle Above 277V 1 minute on 5 minutes off Accuracy 70 to 100 of indicated voltage Battery Type 3 x AAA Operating Altitude 2000m Relative Humidity 0 C to 30 C 32 F to 86 F 90 30 C to 40 C 86 F to 104 F 75 40 C to 55 C 104 F to 131 F 45 Operating Temperature 0 C to 55 C 32 F to 131 F Storage Temperature 0 C to 55 C 32 F to 131 F Dimensions 7 375 x 2 375 x 1 25 AGE ne e Weight 8 102 Sa e Safety CSA C22 2 1010 1 IEC 61010 1 Pollution Degree I e CAT Rating CAT IV 600V CAT III 1000V e CONTINUITY A WARNINGS FUNCTION To ensure safe operation and service of the tester follow these instructions e WORKLIGHT Failure to observe these warnings can result in severe injury or death e Before each use verify meter operation by measuring e LIGHT VIBRATION SOUND INDICATORS a known voltage or current e Never use the m
3. eter on a circuit with voltages that exceed the category based rating of this meter e Do not use the meter during electrical storms or in wet weather Do not use the meter or test leads if they appear to be damaged Ensure meter leads are fully seated and keep fingers away from the metal probe contacts when making measurements Do not open the meter to replace batteries while the probes are connected to a voltage source Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose a shock hazard Shut off and lock out power before testing continuity Always adhere to local and national safety codes Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed e CAT IV 600V SAFETY RATING e MODERN SOLID STATE DESIGN ANTERTE W LISTED Hao KLEIN TOOLS www kleintools com For Professionals Since 1857 SYMBOLS Positive DC Voltage Warning or Caution Negative DC Voltage A Dangerous levels e AC Voltage ol Double Insulated Class II L Earth Ground ETL Certification CAT Ill CAT IV Designed for transient protection Designed for transient protection on indoor measurements at on outdoor measurements taken installations connected directly at the primary supply voltage to the primary source Examples source Examples include outdoor include distribution panels and overhead or underground utility lighting sys
4. ies are not required for visual voltage indication 1 Remove test leads from voltage source 2 Unscrew battery cover and replace 3xAAA batteries CUSTOMER SERVICE KLEIN TOOLS INC 450 Bond Street Lincolnshire IL 60069 1 800 283 6608 www kKleintools com 139575T
5. or for information on how to exercise your rights under the terms of this warranty please contact Klein Tools at 1 800 553 4676 CLEANING Clean the instrument by using a damp cloth Do not use abrasive cleaners or solvents STORAGE Remove the batteries when instrument is not in use for a prolonged period of time Do not expose to high temperatures or humidity After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section allow the instrument to return to normal operating conditions before GFCI Testing using it Ad Check the GFCI Receptacle user manual for more information DISPOSAL RECYCLE Always contact a qualified electrician to resolve wiring problems Caution This symbol indicates that equipment and its accessories A Operate the Push Button on the GFCI Receptacle If the GFCI circuit 4 shall be subject to a separate collection and correct disposal does not trip the receptacle is not operating properly To test the functionality of a Ground Fault Circuit Interrupter receptacle apply leads to the hot and ground terminals for 7 seconds e Ifthe GFCI receptacle is wired properly power to the circuit will go out and the ET200 will stop indicating voltage e Ifthe GFCI receptacle is wired improperly power to the circuit will remain and the ET200 will continue to indicate voltage To resolve an issue contact a qualified electrician Battery Replacement Batter
6. tems in large buildings service and electricity meter FEATURE DETAILS Indicators Lights e LEDs light up numerical voltage level indicators as well as AC and DC or DC indicators e Continuity LED will light up on detection e Voltage detection will function without batteries installed Vibration e Instrument will vibrate in the presence of voltage measurements greater than 48V e Vibration will function only with batteries installed Sound e Instrument will emit a tone in the presence of voltage measurements greater than 48V e Instrument will emit a tone on detection of continuity e Sound will function only with batteries installed Accuracy Accuracy of indicator lights is 70 to 100 of the voltage displayed to account for normal variations in supply voltage Worklight Press the light bulb button above the Klein Tools logo to toggle the worklight on and off Ghost Voltages The approximate input resistance of 15kQ will reduce the possibility of false readings due to ghost voltages on de energized lines Lead Spacing Molded lead holders on the back of the ET200 are spaced correctly to test tamper resistant outlets OPERATING INSTRUCTIONS Measuring Voltages A Time spent operational at voltages above 277V must be less than 60 seconds with a cool off time of at least 5 minutes Tester will turn on automatically when voltage is applied AC Voltage Measurement

Download Pdf Manuals

image

Related Search

Related Contents

  Manuel d`installation général  Grid Player pour iOS version 1.0 © Sensory Software  Nexxt Solutions Terminal Pro-3  Pioneer DEH-2300 Stereo System User Manual  Installation manual Volkswagen Caddy Maxi WAV  EuroCAD Spread&Cut Planner User manual  Recruter un salarié dans son association  送気・送水ポンプユニット MAJ-1203  C-VX870 C-VX872 取扱説明書  