Selador Series ETL User Manual
Contents
1. Sew e Lo Ec If you have questions about your Selador series fixture that are not answered in this manual please contact the supplier of your ETC equipment or ETC Technical Services Americas United Kingdom Electronic Theatre Controls Inc Technical Services Department 3031 Pleasant View Road Middleton WI 53562 800 775 4382 USA toll free 1 608 831 4116 service etcconnect com Asia Electronic Theatre Controls Asia Ltd Technical Services Department Room 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong 852 2799 1220 service etcasia com Electronic Theatre Controls Ltd Technical Services Department 26 28 Victoria Industrial Estate Victoria Road London W3 6UU England 44 0 20 8896 1000 service etceurope com Germany Electronic Theatre Controls GmbH Technical Services Department Ohmstrasse 3 83607 Holzkirchen Germany 49 80 24 47 00 0 techserv hoki etcconnect com Please email comments about this manual to TechComm etcconnect com Selador Series User Manual Document Conventions Throughout this manual the following are used to alert you to notes and safety notices Note Notes are helpful hints and information that is supplemental to the main text gt CAUTION A Caution statement indicates situations where there may be undefined or unwanted consequences of an action potential for
2. Fuseau Corporate Headquarters 3031 Pleasant View Road Box 620979 Middleton Wisconsin 53562 0979 USA Tel 608 831 4116 Fax 608 836 1736 London UK Unit 26 28 Victoria Industrial Estate Victoria Road London W3 600 UK Tel 44 0 20 8896 1000 Fax 44 0 20 8896 2000 Rome IT a Via Pieve Torina 48 00156 Rome Italy Tel 39 06 32 111 683 Fax 44 0 20 8752 8486 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany Tel 49 80 24 47 00 0 Fax 49 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong Tel 852 2799 1220 Fax 852 2799 9325 Service Americas service etcconnect com UK service etceurope com DE techserv hoki etcconnect com Asia service etcasia com Web www etcconnect com w Copyright 2013 ETC All Rights Reserved Product information and specifications subject to change 7400M1200 m Rev G m Released 2013 02
3. if used and clean out any dust and debris All components including the secondary lenses can be cleaned using compressed oil free air as described above or a clean micro fiber cloth The use of any liquid cleaning solution is not recommended for Selador fixtures Inspect all mounting hardware for wear and if necessary clean using compressed oil free air or a soft lint free cloth 15 Selador Series User Manual Cooling Fan Filter Cleaning Cooling fan filters should be inspected at a minimum every six months more frequently if fixtures are powered on for more than four hours per day Use a vacuum cleaner to remove dust from each fan filter In dusty environments or conditions involving the use of smoke machines clean the filters as follows Using fingernail or small flat blade screwdriver remove fan filter cover by prying under one of the two locking tabs e Carefully remove foam fan filter from fan assembly e Gently wash foam fan filter in a solution of mild dishwashing solution and water e Thoroughly rinse each foam fan filter in clear water Patdry or air dry filters e After filters are completely dry reinstall by inserting them into fan assembly Reattach the fan filter cover to the fixture Note Nouser serviceable parts are inside Fuse Capacities All Selador Fixtures use 3AG 250V 1 25 X 0 25 fuses Use the following capacity fuses for all Selador fixtures
4. Note Vivid R replaces the original Vivid fixture as of February 2010 The manufacturer of the K2 LED emitter is phasing out these emitters over the next year Vivid R maintains photometrics equivalent to the original Vivid with higher intensity and uses less power Physical Rugged extruded anodized aluminum construction Advanced thermal management systems for long LED life 01040 C 32 to 104 F ambient operating temperature Available in 11 21 42 and 63 in lengths Fixtures built January 2010 and after On board fan speed control for no noise operation unless in high ambient temperature situations Electrical Yoke trunnion floor stand or pipe hanger mounting options Available in black See Dimensions and LEDs page 3 See Fixture Weight page 10 100V to 240V 50 60 Hz internal power supply Neutrik PowerCon input connector LEDs 5 ft power lead supplied Requires power from non dim source Luxeon Rebel 2 5W LED emitters Lustr Paletta Vivid R Vivid Fire Vivid Ice and Pearl Luxeon K2 3 5W LED emitters original Vivid fixtures manufactured January 2010 or before Optical 50 000 hr LED life See Note About LED Fixtures page 3 Integral 16 field angle optic Pearl Integral 17 field angle optic Vivid R Integral 18 field angle optic original Vivid Integral 26 field angle optic Lustr Paletta Vivid Fire and Vivid Ice Slots for secondary l
5. be inadvertently compromised and performance affected Up and down address buttons are recessed to avoid inadvertent address changes Use a Phillips screwdriver or other blunt device to lightly push the switches To avoid damaging the switches do not use sharp objects or excessive force when changing fixture address Increase LED push button display Decrease push button Addresses must be set between 1 and 505 Selador fixtures are manufactured based on an 11 in LED array or cell Each cell can be addressed individually Eleven inch fixtures have one cell 21 in fixtures have two cells 42 in fixtures have four cells and 63 in fixtures have six cells A 42 in fixture can be addressed as four individual cells one cell or any combination Each Selador fixture must be considered a separate DMX device for the purpose of DMX line loading calculations with the exception of 63 fixtures These 63 fixtures must each be considered 1 5 DMX devices for line loading Fixture Number of Cells Number of DMX Devices Tin Zin line loading practice dictates that no more than 31 devices can be daisy chained together Consequently no combination of Selador fixtures totaling more than 31 DMX devices should be configured in one DMX line For example twenty 6 cell units 30 DMX devices are okay Twenty one 6 cell units 31 5 DMX devices are not acceptable For runs of fixtu
6. brightness operation and 23 C 74 F ambient 38 C 100 F External Temperature steady state achieved at 23 C 74 F 70 C 158 F Installation Power and Data Cabling Requirements Power The Selador series fixture operates on AC power 100 to 240VAC 50 60Hz You may use a circuit powered through an SCR dimmer as long as the dimmer is set to unregulated non dim switched operation Power is supplied through a standard five foot power input cable with Neutrik PowerCon locking pigtail with either an Edison Twistlock or Stage pin male connector Data The Selador series fixtures operate on a DMX control signal The unit is supplied with a 5 pin XLR DMX input connector and 5 pin DMX Thru connector DMX cables should be acceptable for DMX data transmission not microphone cable and should follow the standard pinout The optional secondary data pair is not used by the Selador series fixtures The maximum DMX data run from any DMX source to the last fixture in a chain is 1000 feet 300m Termination is required in the data thru port of the last fixture in each data chain DMX512 pinout for five pin XLR female Common Shield Data Data not connected not connected See Control page 13 for additional information on DMX addressing of Selador Series fixtures 7 Selador Series User Manual Installation Procedures Installing Mounting Hardware Four different options are available for mou
7. data loss or an equipment problem WARNING A Warning statement indicates situations where damage may occur people may be harmed or there are serious or dangerous consequences of an action WARNING RISK OF ELECTRIC SHOCK This warning statement indicates situations where there is a risk of electric shock Safety The Selador series fixtures are intended for professional use only Read entire User Manual before using equipment Please note the following safety notices before use WARNING Note the following safety warnings before use Do not mount the Selador series fixture on or near a flammable surface Use the fixture in dry locations only where humidity does not exceed 90 percent non condensing Fixture is not intended for outdoor use Mount and support the fixture only by the primary suspension holes in the enclosure Suspend the fixture from a suitable structure using only the hardware rated for the weight of the fixture In addition to primary suspension attach a safety cable ETC Model 400SC or other approved safety cable or device to the fixture housing Appropriate attachment points holes are provided in the protruding tabs on either end of the fixture housing Disconnect the unit from power and from DMX before all cleaning and maintenance Maximum ambient temperature Ta 40 C 104 F Maximum exterior surface temperature Tmax 80 C 158 F External Temperature after 5 minutes of full
8. a 7 color fixture across the entire CCT range e Beautifully illuminates skin tones and other objects Paletta Luxeon Rebel 2 5W LED emitters e ull 7 color x7 LED array Optimized for deep pure pastels and saturated colors in a lower profile and affordable fixture e Interacts seamlessly with conventional sources Vivid R Luxeon Rebel 2 5W LED emitters Full 7 color x7 LED array Optimized for high output deep pastels and strong saturated colors Narrow optics for the longest throws Vivid Fire Luxeon Rebel 2 5W LED emitters e Specialized LED array e Optimized for saturated colors at the red end of the spectrum e Strong output for high intensity theatrical environments Vivid Ice Luxeon Rebel 2 5W LED emitters e Specialized LED array Optimized for saturated colors at the blue end of the spectrum Strong output for high intensity theatrical environments Pearl e Luxeon Rebel 2 5W LED emitters e Specialized LED array e High output warm and cool white LEDs for variable color temperature white only light output from 3200 to 5700K Information in this manual is applicable to all Series by ETC products Applications Theaters e Studios e Churches e Hotels e Convention Centers e Schools Application tin m meswme Fen J _ Seim Ke Fig _ Specials P pomi Baci
9. d periods such as channel checks or focusing id d 180mm 10 50 T m 9 25 235m 11 25 290mm 7 1 gt 10 00 255mm DNE 7 1 180mm Floor trunnion dimensions 18 25 465mm 9 25 235 8 75 225mm Paletta Front view dimensions oo 000 00 boo t m Oo z E Om 059 O52 2020200202020 9909 eS Eres eo Mo eco oco Seco m ego porno eco Sum Seco 9290 s g 95 OO A A 6 6 2 2 o2e2 9959 d le o eco oo 999 2020 99 ET S626 2020 2o20 2 5509 ORO e E 9959 0o00 H o 95 uuo NES edo ego e9e Mee O O O O 0202020202090 920 IE 5509 O26 illad Sogo 5 Sogo ME Seco l Sogo 25 gogo gogo m io ee Qo aN oo Qo s E N 9 95 Nt 9585 Qu Ooo E io RA D 9900 9909 ego ego eee 8 edo egeo 9959 bE 2 oso ROR MSS NE quo gt eo 26 0020 proud 26 S68 Seco poo 999 2020 2o20 S626 og 2020 S626 e ege DO ege ege m CR Y ud 9830 ege eo oo ego eco gogo 9959 HET at ogee ages iz oxo 5
10. enses Color Combine secondary lenses for desired beam spread Selador Seven color x7 LED products for superior broad spectrum color mixing Lustr Optimized for highest output in white and light tints in a 7 color fixture Paletta Optimized for strong saturated colors Vivid Vivid R Optimized for strong saturated colors at maximum brightness Selador special purpose LED fixtures Vivid Fire Optimized for high intensity saturated colors on the red end of the spectrum Vivid Ice Optimized for high intensity saturated colors on the blue end of the spectrum Pearl High output warm and cool white LEDs for variable color temperature white only light output Interacts seamlessly with conventional sources Achieves excellent 3200 or any other Correlated Color Temperature white light from 800 to 20 000 K except Vivid Fire Vivid Ice and Pearl Beautifully illuminates skin tones and other objects Deeply saturated colors across an exceptionally wide gamut Color rendering as high as 90 CRI except Vivid Fire Vivid Ice and Pearl Selador Series User Manual Control DMX512 A compliant in and thru 5 pin XLR connectors 8 channel 7 color plus intensity 3 channel warm cool intensity for Pearl Intensity channel minimizes color shift during dimming Digital LED display for address assignment Internal control electronics for smooth low end dimming at 15 bit resolutio
11. er up the software version is briefly displayed then the current DMX address setting is displayed Disconnect the AC Input cable Slide back the locking tab twist the connector counterclockwise and pull to unlock and disconnect the power connector q Power amp Data connections fuse locations 9669 ea m m ijj itl e e e oo e Addressing and fans repeat per cell A Fuse The quarter turn fuse holder requires a straight blade screwdriver to remove and reinstall a fuse Refer to Fuse Capacities page 16 for information about fuse types Control Use the two push buttons on the bottom of the fixture to set the starting address for the fixture View the LED display with the push buttons on the left The top push button increases the number and the bottom push button decreases the number Pressing and holding the push button increases the rate of change When fixtures are powered up they may temporarily respond to DMX address 001 for the first few seconds of operation New address settings take effect after the LED display turns off CAUTION Do not push the up and down address buttons simultaneously or internal fixture software settings can
12. es have complex thermal management systems to minimize these changes With typical usage a Selador fixture will still achieve 70 of its initial output after 50 000 hours of use In individual situations LEDs will be used for different durations and different levels This can eventually lead to minor alterations in color performance necessitating slight adjustment to presets cues or programs All LEDs exhibit a slight color shift as their temperature rises from ambient to operating temperature This may or may not be visible to the eye If this is a concern a five to ten minute warm up cue all color channels at 100 intensity channels at 50 prior to production can minimize this effect Selador Series User Manual Overview Congratulations on your purchase of a Selador Series by ETC product Selador s x7 Color System seven hue technology produces a light and color quality that conventional LED systems cannot duplicate This unique color system produces bright broad spectrum whites and intense colors equally well rendering pigments objects and skin tones in a natural way Vivid Fire and Vivid Ice fixtures use elements of the x7 Color System for superior performance in deep saturated colors Each member of the Selador Series product line is unique and optimized for a specific lighting task Lustr Luxeon Rebel 2 5W LED emitters e ull 7 color x7 LED array Broad spectrum color optimized for the best white and light tints in
13. gogo gogo 960 990 ege ege Smi 2 E Oo 9599 Oo Zozo Seco Soko 995 2020 99 ho N 2020 oS 2020 2o20 N 2626 oo 2020 2686 e eco a 505 26 foo 1 9 ORO O io N 2 ege eco Sozo 990 Zozo 2 9996 Y 9999 Y Selador Series User Manual Rear view to show power data connections and repeating addressing and fan locations Hanging dimensions Safety Cable The safety cable or other approved safety device should be attached to the fixture housing and wrapped around the hanging structure pipe Appropriate attachment points holes are provided in the protruding tabs on either end of the fixture housing Take care to leave as little slack as possible in the safety cable to avoid the cable catching the yoke of the fixture Safety cable attachment points ju e Fixture Weight Total weight depends on how the individual fixture is configured Weights shown do not include secondary lenses Lustr Vivid R Vivid Fire Vivid Ice and Pearl Lbs Lbs L ue Ke e e mp ms 52 e 89 a Does not include mounting hardware Paletta Lbs Lbs 15 Ke tbs a Does not include mounting hardware Installing Secondary Lenses Up to two secondary lenses can be installed in the slots toward
14. ity 0 100 Fixture address 1 Cool white 5700K 0 255 Intensity 0 100 Fixture address 2 Master intensity control 0 255 Intensity 0 100 Note Use individual color channels to create color mix Use Master Intensity Control to set fixture intensity Master Intensity Control Channel 8 must be above 0 for the fixture to output Routine Maintenance General Fixture Cleaning To ensure optimum performance of your Selador series fixture you should perform the following inspections and cleanings at least once a year You may need to inspect or clean the fixture more often depending on the type and amount of use your fixture experiences during the year CAUTION Allow fixture to cool down completely prior to cleaning A Disconnect all power and DMX cables prior to cleaning Check for excessive dust or debris in the heat dissipating fins around the entire fixture enclosure Clean using compressed air or a soft cloth Keeping the heat sink components of the enclosure clean facilitates efficient cooling and extends LED longevity NEVER spray liquids into the fixture NEVER spray compressed air into a fixture that is powered up A can of compressed air or oil free air from an air compressor set at a low setting can be used to blow through the vent holes and remove dust or other debris from the interior of the fixture Dust build up can cause overheating and premature shutdown Remove the secondary lenses
15. n 21 in fixture provides 2 independently controllable cells 42 in fixture provides 4 independently controllable cells 63 in fixture provides 6 independently controllable cells 8 Vivid Fire and Vivid Ice are available in 11 in and 21 in versions only Maximum Power Consumption at Full Intensity Lustr Vivid R Vivid Fire Vivid Ice and Pearl Current A Watts a 1 05 0 60 125W 144W 120 240 2 10 1 20 250W 288 4 20 2 40 500W 576 6 30 3 6 750W 864W a Vivid Fire and Vivid Ice are available in 11 in and 21 in versions only Current A Watts Paletta 0 90 0 50 108W 120W 120 240 1 80 1 00 216W 240W 3 60 2 00 432W 480W 5 40 3 00 648W 720W Vivid Manufactured January 2010 or before Current A Watts 1 35 0 74 162W 178W 120 240 2 70 1 48 324W 356W 5 40 2 96 648W 715W 8 10 4 44 972W 1 068W Dimensions and LEDs Lustr Vivid Vivid R Vivid Fire Vivid Ice and Pearl ___Sizeininches Number of LEDs 057157 2257171 5357171 a Vivid Fire and Vivid Ice are available 11 in and 21 versions only Paletta _Sizeininches Number of LEDs 10 71 x625 ZI8xT1x628 42574625 635 71 625 Note About LED Fixtures All LED sources experience some lessening of light output and some color shift over time Selador Series fixtur
16. nting Selador fixtures e Yoke with C clamp for 11and 21 in units Double yoke with C clamp for two 11 or two 21 in fixtures over under configuration Floor trunnions for all fixtures Pipe hanging brackets for all fixtures Note Trunnions should be installed with the feet inward so that fixtures can be lined up end to end if needed Installation Clearances Cooling and Duty Cycle Selador Series fixtures are equipped with ultra quiet cooling fans These fans are automatically controlled They permit fan free operation when possible and turn on only when needed to provide low noise predictable service for extended periods of time in ambient temperatures up to 104 F 40 C When the fan turns on its speed ramps up slowly in order to minimize the noise differential CAUTION Duty Cycle Operating the fixtures in higher ambient temperatures or low airflow situations may cause the power supply to shut down Following a cool down period the power supply will automatically reset and the fixture will return to operation It is good practice to power down any device with on board electronics to limit unnecessary wear on the devices and eliminate residual use of electricity When not in use Selador fixtures should be powered down by disconnecting from power either at the breaker or by unplugging LED life is adversely affected by high temperature operation Whenever possible avoid turning all channels to 100 for extende
17. res totaling more than 31 DMX devices split the DMX runs by using a DMX splitter 5 Note A fixture with a starting address higher than 505 will not have control of all parameters Therefore 505 is the highest address shown on the address display Selador Series User Manual Each cell of a Selador Series fixture except Pearl occupies eight DMX channels Seven are individual colors and the eighth is the master intensity The table below describes the order and function of each address Lustr Paletta and Vivid R Data Channo coor Function e 28s ensiy 0 103 Fintureaddress 5 Bue 025 01009 s address 7 Masterintenstyconro 0255 Overal intensiy 0 100 Vivid Fire Chann vawe Function Red 025 nensiy 0 103 5 Fixture Notus s Fixture address 7 Masterintenstyconro 255 Overalintensty 0 100 Vivid Ice paschae coor Fixture address Rea 025 904 72 Fixture address 1 Notus Fixture address 2 O SS Fixture address 5 Bue 9255 tensiy 6 100 s Fixture address 7 Master intensity control 0255 Overall intensity 0 100 Pearl Data Chann J Color Value Function Fixture address Warm white 3200 0 255 Intens
18. s the front of the fixture The stacking order and distance from the LED array are not important to the function of the lenses To avoid lenses being too loose and potentially overlapping each other use the narrower slots for thinner lenses To install secondary lenses Step 1 Loosen the screw on the end of the access panel that has the slot in it Loosen screw Step 2 Raise the panel out of the way but leave it attached to the fixture Step 3 Slide the secondary lenses into the slots above the LEDs Step 4 Lower the panel and tighten the screw Selador Series User Manual Connections and Addressing Connect AC input power and DMX data cables to the appropriate ports as shown below The Paletta connectors are located slightly differently than shown in the illustration below However the descriptions and functions described below are the same DMX Input DMX Thru gt gg Addressing Connect the incoming DMX data cable to the DMX Input connector If you are daisy chaining the data to other fixtures or DMX controlled devices connect the next DMX cable to the DMX Thru connector The Selador Series fixtures require that the last fixture on a DMX line be terminated with a 1000 resistor between pins 2 and 3 Connect the AC Input cable Align and insert the power connector Twist the connector clockwise until it locks into place Note Upon pow
19. selador Series by ETC Lustr Paletta Vivid Vivid R Vivid Fire Vivid Ice Pearl User Manual 2010 09 The Selador series of fixtures are intended for professional use only Read entire User Manual before using equipment Copyright 2013 Electronic Theatre Controls Inc All rights reserved Product information and specifications subject to change Part Number 7400M1200 Rev G Released 2013 02 ACCREDITATIONS AND RECOGNITIONS from ETL SEMKO www usa etlsemko com ETL SEMKO is recognized by OSHA in the U S as a Nationally Recognized Testing Laboratory ETL tests to standards developed or approved by the American National Standards Institute ANSI Underwriters Laboratories UL and others Other notable accreditations include the American Association of Laboratories Accreditations A2LA American National Standards Institute ANST International Conference of Building Officials ICBO and the International Electrotechnical Commission of Electrical Equipment IECEE ETL also has accreditations and recognitions from around the globe Visit www etlsemko com accred html for a complete listing Conforms to UL Std 1573 Certified to CSA Std C22 2 No 166 ETC intends this document whether printed or electronic to be provided in its entirety ETC and Selador are registered trademarks of Electronic Theatre Controls Inc in the United States and other countries Other product and company names men
20. tioned herein may be trademarks and or service marks of their respective owners This product is protected by one or more of the following U S Patents 6 016 038 6 150 774 6 788 011 6 806 659 6 683 423 and 7 023 543 Table of Contents Specifications 1 Maximum Power Consumption at Full Intensity 2 Dimensions and LEDs 3 Note About LED 3 4 Applications 5 Document 6 Safety ox Vasa betel damos qureei Cancer tnr dents Ped ene teet don 6 T Power and Data Cabling Requirements 7 E E E EAEE E 7 he ita ouest a 7 Installation Procedures 8 Installing Mounting 8 Installation 8 Safety 10 Fixture Weight 10 Installing Secondary Lenses 11 Connections and Addressing 12 ED E quits 13 Routine Maintenance 15 General Fixture Cleaning 15 Cooling Fan Filter Cleaning 16 Fuse 16 Specifications
Download Pdf Manuals
Related Search
Related Contents
Samsung Galaxy Note 2 manual do usuário(CLARO) Bush DFTA49DVD User's Manual 取扱説明書v1.1(84頁) (A4両面印刷用) User guide Filter coffee machines without discharge stop. - 第 10 章 - IGBT モジュールの EMC 設計 Manuale d`uso Baseo Q Salida en “T” FireLock® 10.52-SPAL Samsung LD190N Bruksanvisning Copyright © All rights reserved.
Failed to retrieve file