Home
RFR100 433MHz TCPIP Reader User Manual
Contents
1. DHCP Client Telnet Operation frequency Signal Strength Range Control Modulation Read Range Omni Angle Antenna 90m Environmental Operation Temperature 30C to 65C Storage Temperature 40 to 80C LED Indicators Power LED TX RX LED TX RX indicator Link LED LAN indicator SVG 12A Connectors RJ 45 female to host CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Mechanicals TOP View Reset NT i LED SE pu LED Power LED Ethernet Power M Antenna Power LED On when reader is powered TX RX LED On while reader is transmitting or receiving a packet LAN LED Blink when there are network activities Ethernet RJ 45 Ethernet jack Antenna SMA connector Power 5Vdc Reset Button Hardware Reset the Reader Network Configuration This section will introduce how to configure the network connection of RFR100 by utility TCPIP exe e RFR100 default IP 192 168 1 127 e Run Network Utility TCPIP exe e Homepage CHAMPTEK User Manual RFR100 433MHz TCPIP Reader 5 Search amp Configurate Utility v1 04 Humber Device Mame MACAddess IPAddress T Password ModelNama Device Mode Broadcast Search by IP e Search devices 1 Broadcast Search If don t know the IP of the device can utilize broadcast to search all the devices in the LAN to configure the parameters Broadcast search LT
2. TTT TTT 2 Search by IP If know the IP of the device not in the same LAN can search by IP to set the parameters search by Dialog Input IP T Cancel CHAMPTEK User Manual RFR100 433MHz TCPIP Reader e Search result 9 Scarch amp Configurate Utility v1 04 001348005477 pa 15815 Yes 1438 Select anyone of the device and will pop up a dialog to check password Senrch amp Configurate Utility v1 04 Conhgurate urbe Devoe Name MAC Addos LiF foyers Basen Modei Hame Devoe tode Broadcast 1 rr 100 13 48 00 5 4 77 192 Cm Search by IP Upgrade Reboot Check Password Default Password 00000000 Password Dialog Enter password CHAMPTEK User Manual RFR100 433MHz TCPIP Reader e Connect to the target device to configure the parameters E DER connect to device HHHH CE Progress get information 18 35 LITT TTT Titi titi T Cancel e Configuration page 1 1 Device Name 2 Network Setting Configuration Utility Firmware version 7 04b437 10 Device name MEREEN Basic Settings Operation Mode Settings Password Settings Network Settings Application IP Mode Stalic E Web Console Enable IP Address 192 168 1 5 DIO listen part Subnet Mask 255 255 255 0 son Gateway Using ping MAC address 10 13 48 00 5A 77 Ethemet Status 100M Ti Save to Module X Abort Not
3. CHAMPTEK User Manual RFR100 433MHz TCPIP Reader RFR100 433MHz TCPIP Reader User Manual Revision 02 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader User Manual Revision Date Description amp 2009 1 15 Preliminary draft 2009 31 00 _ 0 12009817 ___ PS BEE PS Copyright Champtek may have patents patent applications trademark copyrights or other intellectual property rights covering in this document The provision of this information does not grant you any license to these patents trademarks copyrights or other intellectual properties FCC Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation of the device FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against h armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Any changes or modification not expressly approved by the party responsible
4. a rssi const char cmsg char pdata Get the RSSI from a specific packet Parameter cmsg in Tag packet Return value The length of RSSI value WEN NE 15 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Prototype DWORD data data const char cmsg char pdata Get the data from a specific packet Parameter cmsglin Tag packet em Return value The length of tag data INN NE Prototype DWORD data readerid const char cmsg char IT rip Description Get the reader id id from a Get the reader id id from a specific packet packet Parameter cmsglin Tag packet wil NN Return value The length of reader ID INN RN Prototype DWORD data routerid const char cmsg char pdata Parameter cmsglin Tag packet emma Return value The length of router ID WENN RN 16
5. ailed Prototype bool con reconnect Re connect the selected device ref bool con selectdvc Parameter None Return value True False 11 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Command API Prototype void param settimeout int timevalue Setting the threshold of command timeout Timevalue in Command timeout int prtcl startdvc Description Start the reader to transfer the tag data back to the host through Ethernet Parameter None Return Value 0 Successful Successful operation 1 Time out No response 2 Error Failed operation EBENE EISEN Description Stop the reader to transfer the tag data back to the host through Ethernet Parameter None Return value 0 Successful operation successful 1 Timeout No response 2 Error Reader received command but failed Prototype int prtcl resetmcu Software reset the reader Return Value 0 Successful Successful operation 1 Time out No response 2 Error Failed operation Comment After reset the reader the Ethernet connection will be disconnected Need to re connect the reader for further operation 12 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Prototype int prtcl resettcp Software reset the Ethernet module Return Value 0 Successful Successful operation 1 Time out No response 2 Error Failed operation Comment After reset the Ethernet module the Ethernet connection wil
6. could void the user s authority to operate the device CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Introduction RFR100 433MHz Reader by Champtek is a RFID monitoring system designed to receive all tags data through transmission frequency of 433 92 MHz It was designed for easy setup configuration and usage RFR100 provides Ethernet interface to communicate with backend host Host can easily search all available Champtek reader s and setup related parameters Besides It made a significant achievement of the system throughput Up to 160 tag reports per second to prevent from the data loss for the high density implement RFR100 built in smart channel clear detection function indicates strength of channel interference that reduce the time and cost to setup the system Reader feedbacks all the RSSI value of the packet received from the tags that is useful for the application of the real time positioning system RFR100 uses cyclic redundancy check to ensure the data integrity and provide API to reduce the time to design the application software Features User configurable identification range 1m to 90m Smart channel clear detection function Complete command set and API support Advanced two layer anti collision technique identifying up to 160 tags per second CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Specification Reader Communication Protocol Ethernet 10 100M Fast Ethernet Protocols TCP IP UDP ICMP ARP
7. ice Do not change the value the DIO listen port 5001 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader e Configuration page 2 1 Reader Operation mode and listen port 2 Serial Setting Do not change the default setting Configuration Utility Fimware version mad JJ Device name TENERE Basic Settings Operation Mode Settings Password Settings Serial 1 Operation mode CP Serve gt 115200 gt Listen Port Save to Module X Abort e Configuration page 2 1 Change password Default password is 00000000 2 Change Device name Configuration Utility Firmware version 2 04bA3 Fi m Device name Basic Settings Operation Mode Settings Password Settings New password Contor Save Cancel Save to Module X Abort User Manual RFR100 433MHz TCPIP Reader e Utility Upgrade if needed 59 Search amp Configurate Utility vl 04 Configurate Password Model Broadcast PESTE 00 13 48 0054 77 92 5 res Search by IP Upgrade Reboot Name Device Mode d L CT MER 1 439 Packet Format End ode OxOd 000000 999999 00 63 000000999999 00 99 xOa Status indicates the tag s condition such as moving still etc The content of Data depends on different groups of tag Implementation Notice e Keep away from potential RF radiators such as electronic radio equipments for minimizing inte rfere
8. ime out No response 2 Error Failed operation Data Handling API Prototype int prtcl rssi start Get the channel RSSI information into buffer Return value 0 Successful operation successful 1 Timeout No response 2 Error Reader received command but failed int prtcl rssi stop Stop receiving the channel RSSI information Parameter None Return value 0 Successful operation successful 1 Timeout No response 2 Error Reader received command but failed DWORD data pop msg char Ipbuf DWORD nSize Move a tag packet from the buffer to specific memory Parameter Ipbuf Tag packet uem memes O Return value Tag Packet real size INN ______ 14 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Prototype DWORD data pop rssi Get the RSSI message from the buffer Return value RSSI message 1 No data in the buffer Prototype DWORD data group const char cmsg char pdata Get the group code from a specific packet Parameter cmsglin Tag packet ee O Return value The length of group code Prototype DWORD data tagid const char cmsg char pdata Get the tag id from a specific packet Parameter cmsglin Tag packet pdata Tag ID Return value The length of tag ID 0 Failed Prototype DWORD data tagstatus const char cmsg char pdata Parameter cmsglin Tag packet 5 5 5 5 5 5 Return value The length of tag status BEN ia Prototype DWORD dat
9. l be disconnected Need to re connect the reader for further operation Prototype int prtcl getidnumber DWORD idnum Inquire the ID of the reader Idnum out 000000 999999 decimal Return value 0 Successful Successful operation 1 Time out No response 2 Error Failed operation Prototype int prtcl setidnumber DWORD idnum Set the ID of the reader Idnum in 000000 999999 decimal Return value Successful Successful operation 1 Timeout No response 2 Error Failed operation 3 parameter The parameter is illegal Prototype int prtcl setRSSlrange unsigned short range Set the receiving RSSI range of the reader Parameter range in 00 99 decimal Ex If want to reader only send back the packet above 80dbm Set rangelin to 80 Return value 0 Successful Successful operation 1 Timeout No response 2 Error Failed operation 3 parameter The parameter is illegal 13 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader Prototype int prtcl getRSSlrange unsigned short range Inquire the RSSI range setting of the read er range out The receiving RSSI range of the reader Return value 0 Successful Successful operation 1 Time out No response 2 Error Failed operation Prototype int prtcl getfirmwareversion char version Inquire the firmware version of the reader Return value 0 Successful Successful operation 1 T
10. nce i e engine monitor etc utilize the channel clear detection feature to pre scan the interference and then choose the best place to setup the reader And readers should be mounted at reasonable height for better performance e RFR100 supports wide range of antennas for different coverage areas high quality SMA coaxial cable may be use to separate the antennas from Reader 10 CHAMPTEK User Manual RFR100 433MHz TCPIP Reader e Recommends CAT 5 5E or CAT 6 high quality Ethernet wire cable for RFR100 e RFR100 is typical indoor used for outdoor environment the Reader can be protected in a NEMA enclosure The operation performance will be reduced the negatively impacted by nature weather conditions such as moisture excessive temperature APIs Champtek also provides efficient C APIs to reduce the time of software development This section describes how to use the APIs to setup and control RFR100 Network Connection API DWORD con connectdvc char ip unsigned short port Connect the remote reader with assigned IP and Port Parameter iplinput The address of the IP port input The communication port of the reader Return value Connection ID Program automatically assigns this connection ID to the reader Null Failed Prototype bool con selectdvc DWORD handle Select a Pr E reader before send a command parameter Handlelinputl ConnectionID Connection ID Return value True False F