Directions for installation and maintenance

image

Contents

1. This Heat pump is exclusively for heating swimming pools Any other use not in conformity and random will be considered as dangerous and unsuitable The assembly the electric connection and the start up must be carried out by specialized and professional person JA 16A 250V C When connect plug to socket power supply please make sure that live wire neutral wire earth wire to plug should be connected as right drawing It is essential to maintain the temperature in the swimming pool lower than the recommended value by the swimming pool s manufacturer Please make sure that minimum water flow speed is 3 0m h In a concern to a constant improvement our products can be modified without notice the present pictures in this note or the characteristics which are described are not contractual 3 Delivery s control At the delivery time check the condition of packing in case of damages have reservation about them to the carrier before 48 hours and by registered letter with acknowledged receipt Before any manipulation check the complete state of the machine 4 Technical description Characteristics Heating consumption power kW MENT Heating restored power kW Heating nominal intensity A Air flow m3 H 1400 Noise level d B A 48 Refrigerant gas H410a Rate of average filling of gas g 550 Overall sizes L x W x H cm 78 x 27 x 51 Possible variations of value according t
2. interface But can t change parameters If the heat pump is running the LED display shows current water temperature If the heat pump is turnoff the LED display shows current time Change Factory O Water temperature setting 15 40 C 5 Compressor protection 95 110 95 Exhaust temperature Automatic restart Water pump mode Water temperature 9 99 C 6 Compressor Exhaust temperature 9 125 C Parameter 0 Parameter 1 Parameter 2 Parameter 3 Water temperature setting 15 40 1 Water temperature setting 95 110 C 1 Automatic restarting 0 1 Water pump mode 0 1 factory setting 27 factory setting 95 factory setting 1 factory setting 1 Parameter 4 Parameter 5 Parameter 6 Water temperature difference Water temperature Compressor exhaust temperature to restart 1 40 C factory setting 2 C Setting the time press CLOCK botton to set the time The time displayed blinks press CLOCK botton again and then use the arrow 4 and P to change the hour setting To change the minutes press CLOCK botton again Once the correct time is set press CLOCK botton again the end The display returns to normal after 8 seconds Timer switch ON and Timer switch OFF Once the time has been set correctly this function allows a machine start time and a machi
3. pump to the filtration pump by contacting relay non supplied to insert in the feeding circuit of the heat pump The remmonded water flow speed is 3m h Removed control panel An extension cord allows the removal of the panel in inserting it in a standard electric box into the technical local the option is supplied with a cover allowing to seal the aperture let by the removal of the control panel Procedure of use External Appliance or Button of heat Display Heat pump answer Engage the circuit breaker of the heat Put the heat pump under tension Display current time Engage the circuit breaker of pump of Put in circulation filtration the swimming pool water into the pipes Set the water The heat pump heats temperature until the required into the dinsishlo temperature immi adjustable from swimming pool 7 Press the button Start between 60 second Press the button Immediate stop and wait Use the circuit breaker of pump of filtration and heat pump Switch off Complete stop 6 Water Flow and refrigerating circuit pressure After putting into service do the settings of pressure of the refrigerant circuit for having an optimal operating of the heat pump following Stage 1 Before starting the H
4. Pressure and gas intake Hot water lt Cold water Compressor Condenser exchanger Safety and control systems The heat pump is fitted out Temperature control Atemperature sensor placed on the exchanger ensuring the cut of the heat pump when the temperature of the water reaches the required temperature The normal cycle restarts when the temperature in the exchanger goes down to a temperature lower of 2 factory settings than this required With 4 safety systems gt A water flow detector placed at the exit of the exchanger A high pressure gas circuit breaker a low pressure gas circuit breaker An outlet compressor temperature sensor If a defect occurs on one of these systems defective system off line or abnormal measured value a message of defect appears on the display screen see the paragraph Error codes and what to do of this note Caution the removal or the shunt of one of the control or safety systems involves the cancellation of the guarantee Electric diagram 71 x CN19 Q CNA _ Compressor Temp Water inlet Temp 5 Installation Rules of installation Electric and hydraulic connections must be carried out according to standards in effect NF C 15 100 CE I 364 The machine must be installed outside The machine must be posed on its ant vibratory studs set and lying flat and on a massive base concrete slab this base must hav
5. Swimming pool heat pump Directions for installation and maintenance contents SE iiid trece Me p3 s GC AUCION EMITE p3 Delivery control aa eee p4 Technical description p4 Technical characteristics Outside Inside BP 50WS C explored view Wire control operation General diagram of the refrigerating circuit Safety and control systems Electric diagram ussssecikaxvEdduE p12 Rules of installation Hydraulic connections Electric connections Procedure of use Water flow and refrigerating circuit pressure p16 Environment problem c ee erre p17 Error messages and what to do eres p18 1 Introduction We thank you for having chosen our Heat pump This installation and maintenance notice contains the necessary information to its installation delivery control the installation the connections and to its repair It is a complementary document to the user s manual which describes its instructions for use We invite you to read it first 2 Caution This document is an integral part of the product and it must stays in the technical room
6. e a sufficient height to prevent any entry of water by the bottom of the machine Height must be adjusted to fit the connector collecting the condensates The obstacles such as wall and vegetation must be separated from the machine as indicated on the diagram below Exhausting side Do not to install the Heat pump in a confined place the fan would recycle its air and the Heat pump would be down performance The fan should not blow towards the windows or crossing point Safety distance between the swimming pool and the foot bath the fitter must imperatively refer to the standard C15 100 section 702 the machine should not be installed in volume 1 surrounding the swimming pool but at least in volume 2 so at a distance of 3 m minimum of the swimming pool and foot bath Other precautions of installation Do not to install the machine near a way with circulation of car in order to avoid mud projections Avoid directing blowing against dominant winds If the machine is intended to be used in winter put it in a place protected from the falls of snow The machine must be able to be supervised in order that children do not play around Hydraulic connections To respect imperatively Connection is carried out with a by pass located on the circuit of filtration upstream appliances of the chemical treatment of water Technical room Heat Pump Connect intake outlet water PVC pipes DN5O to the openings of the machine in follow
7. eat Pump ambient temperature around 20 C refrigerant meter shows pressure from 14 to 16kg cm Stage 2 Close completely the by pass valve and open large inlet and outlet valves of the Heat Pump in these conditions the totality of the water flow goes by the Heat Pump Put into service the Heat Pump in heating mode wait for the indicated pressure being stabilized the correct setting of the pressure is from 21 to 35 kg cm In most of cases pump of filtration given a flow until 20m h you do not have to open the by pass valve If the stabilized pressure is under 21kg cnv the progressive opening of the by pass valve will allow rising this pressure The adjustment of the by pass valve done you have in principle no reason to modify it during the season See the paragraph Environment problem too 7 Environment problem Under certain external conditions the heat exchanges between the refrigerant and the water on one hand and between the fluid and the air on the other hand are insufficient the consequence is that the refrigerating circuit runs up in pressure and the compressor consumes more electricity The temperature sensors compressor outlet and the magnetic circuit breaker on the compressor power supply protect the compressor from these extreme conditions the error messages EE 06 occur The condition causing this situation is as follows In heating mode insufficient water flow close the by pass valve for increasin
8. exhaust temperature sensor Wire control Communication error Signal cable of wire Control is loose Check the connection of signal cable
9. g the refrigerant exchange water Note these error codes are likely to occur if temperature of swimming pool water is high and the ambient air is hot 8 Error codes and what to do This table explains the error codes caused by a defective regulating component or by a security operation Screen and state Second reason if of the heat water Component Possible Intervention the intervention is without effect Sensor disconnected non supplied or defective Check the connections the wires change it or replace the electronic card Water temperature sensor compressor exhaust temperature sensor Sensor disconnected non supplied or defective Insufficient water v Check the water flow High pressure i Low pressure Replace the pressure switch Have protection Too much refrigerant the heat pump checked by a gas present refrigeration technician Not enough Have the heat pump checked by a Low pressure refrigerant gas refrigeration technician Check the connections the wires change it or replace the electronic card protecuen Leak in the cooling Have the heat pump checked by a conduits refrigeration technician Flow switch disconnected non supplied or defective Check the connections the wires change it or replace the electronic card Compressor exhaust temperature Environment problem detected up to 95 Refrigerant leakage more than 3 times Capillary is half blocked 1HR compressor
10. ing the inlet outlet indications grease the worms before screwing Blowing gt By pass Chemical treatme DHS Swimming Pool Drain of the condensates insert the plastic elbow in the hole of evacuation of the bottom and connect the pipe if need Electric connections CAUTION before connecting the machine make sure that the feeder is disconnected to the electrical network The electric installation must be carried out by an experienced electrician and the supply must come from a severing equipment and differential protection the whole must be carried out according to standards in force in the country where the material is installed Characteristics of the electric supply 230 V 10 single phase current 50 Hz Mode of neutral TT and TN S the circuit of heat pump must be connected to an earth circuit Characteristic minimum of the protection Protection must be of 16 A by circuit breaker or fuse it must protect the Heat pump exclusively the circuit breaker must be specified with curve D the fuse must be specified Am Differential protection 30 mA the length of cable between the connector block of the heat pump and the protection of should not exceed 12 m Control The heat pump is fitted out with a water flow detector which function is to apply the signal to the electronic card when the water flow is sufficient We recommend when it is possible to control the heat
11. ne stop time to be programmedduring the day Press TIMER botton the time displayed and ON to blink press TIMER ON botton again Change the hour using the and keys Press TIMER botton again to change the minutes using the 4 P keys Press TIMER botton again the end Press TIMER OFF botton the time displayed and OFF to blink press TIMER OFF botton again Change the hour using the and keys Press TIMER OFF botton again to change the minutes using the 4 gt keys Press TIMER OFF botton again the end The time setting is from O to 24 hours to recycle When the setting time for on and off is the same the setting time is not available When the setting timer Press CLOCK to deactivate TIMER General diagram of the refrigerating circuit Swimming pool water s heating mode The cold and liquid refrigerant fluid absorbs the heat contained in the air through the evaporator gilled radiator in which it is vaporizing it is then put up in pressure and in temperature by the compressor which sends it in the condenser exchanger where it loses its heat in giving it to the water of swimming pool and comes back in liquid state it loses its pressure and still cools in the expansion capillaries before turning back to the evaporator for a new cycle Evaporator gilled radiator Expansion capillary Cold air
12. o climatic conditions Outside N N se Control pane Fast connection for water outlet Fan protection grid blow side SSE 222 Refrigerant pressure manometer m uv Wire connection for power supply N Metal cabinet Top cover Fast connection for water intlet Inside Front sheet cover and panel removed 9 Evaporator BP 50WS C Explored view meum a Temm Topco amans 4 rama DC HEIL C Um Were 7m Um C mundus Fame Wire control operation The function of the LED display and control LED display SET button Press 4 gt to set and check the operation data TIMERON CLOCK ot Press 9 to turn on turn off the units TIMER button CLOCK button Set the operation parameter When the unit powered up but not running press 4 or toenter operation parameter interface parameter from 0 5 see Operation Parameter Table Press SET to enter current parameter setting press 4 or to set data for parameter press SET again exit the current parameter setting No press in 8s it will exit the setting interface If the heat pump is running press 4 or to enter operation parameter check