Home
TDMoE Card for Loop-O9500R
Contents
1. re TDMoE Card for Loop O9500R Features e Hot pluggable interface card for O9500R e Four Ethernet Ports for WAN or LAN port assignment e Two combo Gigabit Ethernet GbE with 2 RJ45 and 2 SFP housing e Two 10 100 1000 BaseT Ethernet e WAN 1 1 Link Aggregation IEEE 802 1d e Max backplane bandwidth 8M Nx64K bps e Jumbo Frame reach up to 10K bytes e Switching amp Bridging e VLAN e Concurrent 255 out of 1 4094 VLAN e Q in Q e Qos e User configurable CoS e User configurable ToS in outgoing IP frame e Pseduo wire circuits bundles e For the entire card Max 64 PW e For E1 Max 32 PW per E1 Average 16 PW per E1 e MAC learning max MAC table 8192 entry e Packet Delay Variation e Max 256ms for E1 e Max 340ms for T1 e L2 switch protocol RSTP STP VLAN e Jitter amp Wander e PPM per G 823 Traffic e IETF TDMoIP RFC5087 SAToP RFC4553 and CESoPSN RFC5086 compliant e ROHS Compliant Description Loop Telecom s TDMoE plug in card is designed for the Loop O9500R TDMoE card is used to transport TDM traffic over IP network in addition to Ethernet traffic As the communications network migrates from TDM to IP the TDMoE card provides a flexible and cost effective choice for the transport of legacy TDM signals It provides four Ethernet ports with no limitation for WAN or LAN port assignment The TDMoE card support point to point and point to multi point voice and date application For t
2. 1 bR YA YA AA UKA KA AA AYA AA AYA YA YA YA AYA AA o o e LOOP TELECOMMUNICATION INTERNATIONAL INC EENET ISO 9001 ISO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 1 03 MAR 2009 Subject to change without notice Magneto Interface Card for Loop O9500R Features e 12 telephone connections for Magneto e Supports MRD Manual Ring down e Supports Magneto to FXS speak PLAR function e Supports dual type L1 L2 and L1 GND magneto phone or MRD e 16Vrms minimum detectable ring Description The twelve channel MAG plug in card is designed of the low speed single slot of Loop O9500R series This module allows communications between magneto telephones With the card set in PLAR mode communications can take place between a magneto telephone and a regular telephone All signaling is carried transparently by the
3. Model ROHS compliant Description Note Main Unit Loop O9500 R 4E1 cc G 4 channel E1 plug in card For cc option This card can also be used in the please refer to the table below for detail Loop AM3440 A B C information Loop 09500 R 41T1 G 4 channel T1 plug in card This card can also be used in the Loop AM3440 A B C Accessories User s Manual All User s Manuals are RoHS compliant Loop O9500 R 4E1T1 UM Optional hard copy paper User s Manual ACD version of the manual is already included as a standard package m Where cc Is used to select connector cC Description Note RJ RJ48C connector BNC BNC connector Product Specifications for 4E1 T1 Interface Card Network Line Interface 4E1 Line Rate 2 048 Mbps 50 ppm Framing ITU G 704 Line Code AMI or HDB3 Connector BNC RJ48C Input Signal ITU G 703 Electrical 75 ohm Coax 120 ohm twisted pair Output Signal ITU G 703 Jitter ITU G 823 Network Line Interface 4T1 Line Rate 1 544 Mbps 32 ppm Output Signal DSX1w 0 7 5 15 dB LBO Line Code AMI or B8ZS Framing D4 ESF selectable Input Signal DSX 1 0 dB to 30 dB w ALBO Connector RJ48C Application Illustration All Other Cards QE1 QT1 avs LOOP TELECOMMUNICATION INTERNATIONAL INC Loop Telecom com ISO 900 1 150 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Ru
4. i AM3440 1 FOM Card 2 Protection ho Protection FOM Card 2 Port 1 Port 1 FOM Card 1 FOM Card 1 Port 1 Port 1 09500R AM3440 1 FOM Card 2 lt r ers _y FOM Card 2 Port 1 Port 1 sass LOOP TELECOMMUNICATION INTERNATIONAL INC ISO 9001 1ISO 14001 mm PATA VA Telecom Loop Ielecom com Worldwide 8F No 8 Hsin Ann Road Science Based Industrial Park Hsinchu Taiwan 30078 Tel 886 3 578 7696 Fax 886 3 564 6272 www LoopTelecom com sales loop com tw 2011 Loop Telecom Version 2 25 OCT 201 Taipei Taiwan 6F No 36 Alley 38 Lane 358 Rueiguang Road Neihu Taiwan 11492 Tel 886 2 2659 0399 Fax 886 2 2659 2325 michael_tzeng loop com tw munication International Inc 1 North America 8 Carrick Road Palm Beach Gardens Florida 33418 U S A Tel 1 561 627 7947 Fax 1 561 627 6615 jimber561 aol com Tianjin China No 240 Baidi Road Nankai District Tianjin 300192 China Tel 86 22 8789 4027 Fax 86 22 8789 0344 wym loop tj com All Rights Reserved Subject to change without notice yA 8RS232 Interface Card for Loop O9500R Features Support X 50 division 2 and X 54 Single slot Two card types 8 RJ48 only card 8 ports RS232 Async 2 RJ48 2 DB44 card Up to 4 ports RS232 Sync 4 ports RS232 Async YS ONASWONAS e LED status indicator e Hot swappable a e Support Async rates from 600bps to 38400 bps ca e Support Sync rates from 600bps to 64000 b
5. without Ground Start and Metering Pulse Used with 12 RJ11 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR without Ground Start and Metering Pulse PLAR bit programmable function Used with 12 RJ11 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR Metering Pulse Used with 12 RJ11 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR and PLAR bit programmable function Metering Pulse Used with 12 RJ11 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR Ground Start Used with 12 RJ11 Note 12FXS x cards with H W ver L and F W V 3 01 01 or newer versions It can also be used in the Loop AM3440 A B C 12FXS GMP includes all FXS card functions For sn option please refer to the table below for detail information pt power type For pt option please refer to the table below fro detail information Loop O9500 R 12FXS GM pt G 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR Ground Start and Metering Pulse Used with 12 RJ11 Loop O9500 R 12FXS GMP pt G 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR and PLAR bit programmable function Ground Start and Metering Pulse Used with 12 RJ11 Loop 09500 R 12FXO G 12 channel FXO plug in card with 600 900 Impedance Battery Reverse and Loop Start l Without Ground Start and Metering Pulse 12FXO GM inc
6. 12KHz and 16KHz metering pulse option A B C D signaling bit software programmable A law or u law coding Most signaling conventions supported Multi color LED indicators for each card Intended for use with 48Vdc powered main units RJ 21X Telco 50 pin Connector Occupies two full size slot slots 11 16 of O9500R device Description The 24FXS 24FXO plug in cards are designed for the dual slot of Loop O9500R device It allows voice frequency interfaces to be multiplexed as a 64 Kbps DSO signal onto a digital network The 24FXS provides 24 voice interfaces connect to telephones The 24FXO provide connections from telephone lines either from a central office or from a PBX in a single RJ21X Telco 50pin connector Coding is either A law or u law selectable by user Most popular signaling conventions are supported including PLAR Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Description Note ROHS compliant Loop O9500 R 24FXS sn pt G 24 channel FXS plug in card with 600 900 Impedance Battery Reverse Loop Start and PLAR Without Ground Start and Metering Pulse Loop O09500 R 24FXS P sn pt G 24 channel FXS plug in card with 600 900 MACH ONS Impedance Battery Reverse Loop Start PLAR and PLAR bit programmable Without Ground Start and Metering Pulse These card
7. Information To specify options choose from list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Model Description Note Main Unit Loop 09500 R 8RS232 Ru G 8 port RS232 plug in card with X 50 subrate This card can also be used in the multiplexing scheme and X 54 encoding with Loop AM3440 A B C 8 RJ48 connectors for 8 RS232 Async ports Loop 09500 R 8RS232 DB G 8 port RS232 plug in card with X 50 subrate Two conversion cables are included Each cable has one multiplexing scheme and X 54 encoding with DB44 connector to one DB9 and 2 RJ48 connectors and 2 DB44 connectors two DB25 connectors for Async and Sync ports This card can also be used in the Loop AM3440 A B C Conversion Cables All conversion cables are RoHS compliant Loop ACC CAB DB44M DSUB 44 pin Male to two DSUB 25 Used in Loop 09500 R 8RS232 DB G 100 2DB25F 1DBO9F DB pin Female one DSBU 9 pin Female plug in card Accessories Length 100cm User s Manual All User s Manuals are RoHS compliant Loop 0O9500 R 8RS232 UM Optional hard copy paper User s Manual ACD version of the manual is already included as a standard package Product Specifications for DTE Interface Cards DTE RS232 X 50 mux 8 port Interface RS232 V 24 Data Port MUX Data Rate Card Type Eight RJ48 Two DB44 Two RJ48 Connector Conversion Cable Electrical Up to twelve 8 port RS232 cards Maximum 5
8. Manual paper copy Loop 09500 R RTB UM Note A CD version of the manual is already included as standard package Product Specifications for Router B Interface Card Number of ports 8 LAN ports Max 64 WAN ports Each WAN port has data rate n x 64K bps 1 lt n lt 32 lt 8Mbps for total of all 64 WAN ports Physical Interface 10 100 BaseT x 8 Connector RJ45 Routing protocol RIP I RIP II OSPF Static Supporting Protocols PPP IPCP BCP MLPPP HDLC Frame Relay and Cisco compatible HDLC NAT NAPT DHCP Diagnostic Ping Trace route QoS Rate limit Application Illustrations Application A As a Router E1 11 E1 T1 Application B As an Inband Management Element Network AA Managemen __Work amp tation Network Element Application C As a LAN Bridge s LOOP TELECOMMUNICATION INTERNATIONAL INC LoopTelecom com ISO 9001 ISO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj
9. Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 300 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2010 Loop Telecommunication International Inc All Rights Reserved Version 4 16 MAR 2010 Subject to change without notice TOE 4E1 T1 Interface Card ame for Loop O9500R Features e Contains four E1 T1 Interface e Usable as a CSU DSU T1 to E1 converter e Full TSI capability among all time slots in the main unit e Remote diagnostics e Single LED indicator per port e Software field upgradable Description Loop Telecom s QT1 QE1 plug in cards are a series of 2 different plug in cards designed for the Loop O9500R They allow each DSO time slot in QT1 or QE1 interfaces to be interchanged and multiplexed onto a digital network Continuous error checking performance polling and in service diagnostics are provided through the main controller of the Loop O9500R In addition an LED on the plug in provides status indication Ordering Information To specify options choose from list below
10. V 35 V 36 cards Data Rate 56 or 64 Kbps n 1 to 32 Connector For V 35 card DB25S optional conversion cable DB25S to M34 connector For V 36 card DB25S optional conversion cable DB25S to DB37 connector DTE EIA530 RS449 Interface 6 EIA530A 6RS449A Data Port Up to six 6 port EIA530 DTE card Data Rate 56 or 64 Kbps n 1 to 32 Connector DB25S optional conversion cable DB25S male to DB37 female connector for RS449 Application Illustration V 35 X 21 V 36 RS449 HUA E1530 RS232 Interfaces Interfaces zwa LOOP TELECOMMUNICATION INTERNATIONAL INC Telecom wawi ISO 900 11SO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 1 08 MAR 2009 Subject to change without notice FO E amp M Voice Card for Loop 09500R Features e RJ45 x 8 connector for E amp M Ss e E amp M signaling types are
11. contact from the E1 or fiber cable to a dry relay contact output Support Normal Closed Open BUBB SS N wee 4 j n Description Loop Telecom s Dry Contact card and Dry Contact type B plug in card are designed for the Loop O9500R These Dry Contact cards which can be assigned to 2 DSO time slots or 16 DSO time slots are used for 1 collecting alarm inputs from non SNMP devices and issuing alarm via SNMP trap 2 sending commands to close remote contacts for relay devices and 3 repeat a remote contact closure with a local contact closure The difference between Dry Contact and Dry Contact type B interface cards is the higher voltage for type B interface card These cards are used to detect remote contact closures activated by alarms and to provide remote contact closures to control network operation where needed When 2 DSO time slots are chosen to carry the dry contact signals 8 bits of one time slot carry the input contact status and 8 bits of the other carry the output contact commands When 16 DSO time slots are chosen to carry the dry contact signals one bit of each of 8 DSO time slot carry the input contact status and one bit of each of other 8 DSO carry the output commands Ordering Information To specify options choose from list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Description Note Main Unit Loop 09500 R 8DC G 8 channel dry c
12. entry Packet Delay Variation Unframed T1 Up to 340 ms Framed T1 Up to 256 ms E1 up to 256 ms Framed T1 with CAS Up to 192 ms Packet transparency support for all types of packet types including IEEE 802 1q VLAN and 802 1ad Q in Q Up to 10K bytes User configurable 802 1p CoS ToS in out going IP frame Ingress packet Rate limiting buckets per port for ethernet port Supporting Rate based and Priority based rate limiting for LAN port Granularity a From 64 Kbps to 1 Mbps in increments of 64 Kbps b From 1 Mbps to 100 Mbps in increments of 1 Mbps c From 100 Mbps to 1000 Mbps in increments of 10Mbps Pause frame issued when the traffic exceeding the limited rate before packet dropped following IEEE802 3X WAN supports 1 1 Link Aggregation TDMolP RFC5087 SAToP RFC4553 CESoPSN RFC5086 802 1q 802 1p 802 1d 802 3 802 3u 802 3x 802 32 802 1s 802 1w 802 1AX Application Illustrations TDMoE plug in card in O9500R is to transport TDM traffic voice signals E1 T1 DTEs Ethernet into IP Traffic O9500R with TDMoE Card TDM Ethernet DE m W8110 W8110 IP6700 Point to Point Application with WAN 1 1 Aggregation O9SOOR at A site O9SOOR at B site Ethernet WAN 1 1 Link Aggregation i Ethernet Point to Multipoint Application ETI El TI El T1 DTE El T1 DTE Ethernet Network 2 waza ag lt Voice Signals E1 T1 DTE Etherne E1 T1 El TI E1 T1 DT
13. subrate port per 64K bps Aevne montis Mux mode 0 6K 1 2K 2 4K 4 8K 9 6K y Independent mode 0 6K 1 2K 2 4K 4 8K 9 6K 19 2K 38 4K Mux mode 0 6K 1 2K 2 4K 4 8K 9 6K Synchronous Independent mode 0 6K 1 2K 2 4K 4 8K 9 6K 19 2K 38 4K 48K 64K Port Number 1 2 3 4 5 6 7 8 Async Async Async Async Async Async Async Async Async Sync Async Sync Async Async Sync Async Sync Async Async Async Eight RJ48 port 1 to port 8 DB44 port1 port2 port3 DB44 port4 port5 port6 RJ48 port7 and RJ48 port8 A three into one conversion cable adapts the DB44 connector to 3 connecters one DB9S and two DB25S RS232 Interface DCE Application Illustration Loop 09500R RS232 E1 T1 X 50 G shdsl Interfaces H U Interfaces LOOP TELECOMMUNICATION INTERNATIONAL INC ma Ts t a a mm FATATA YE a eom ta ISO 9001 ISO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2010 Loop Telecommu
14. 24 channel FXO plug in module with 600 900 Impedance Battery Reverse Ground Start and Metering Pulse Accessories User s Manual Loop O9500 R FXSFXO UM User s Manual paper copy Note A CD version of the manual is already included as standard package For 24 channel FXS card E Where sn is used to select special function If this option is not required omit the sn field in the ordering code sn Description Note Si FXS Loop Feed 48 Vdc with 35 mA current limit S4 Remove alarm tone S5 Double ring tone transmit Note For sn special function please contact your nearest Loop sales representative E Where pt is used to select the following functions pt Description Note PWR complied with 48 Vdc SD48 power modules PWRIE1613 complied with IEEE1613 standard and with 48 Vdc SD48 power modules 24 FXS FXO Product Specifications Voice Card 24FXS 24FXO Connector Alarm Conditioning Encoding AC Impedance Longitudinal Conversion Loss Cross talk measure Gain Adjustment Signal Distortion Frequency Response Idle Channel Noise Variation of Gain FXO FXS Loop Feed FXS signalling FXS Ringing Signaling Optional Signaling for special order Signaling Bit A B C D One RJ21X CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable together for all Balanced 600 or 900 ohms selectable together for all gt 46dB Max 70dBm0 21 to 10 dB 0 1dB step transmit amp receive gt
15. 25dB with 1004 Hz OdBm input 0 25 to 1 dB from 300 to 3400 Hz coincide with ITU T G 712 Max 65 dBm0p 0 5dB Ringing REN 0 5B AC Detectable Ringing 25 Vrms Loop Resistance lt 1800 Q DC Impedance ON HOOkK gt IMO DC Impedance OFF HOOK 235 O 25 mA feed 90 O 100 mA feed 48Vdc with 25mA current limit per port Jumper Selectable 25mA 30mA 35mA Normal Automatic Ring down 1 REN at 5K meters per port 16 7Hz 20Hz 25Hz 50Hz user selectable for all ports 38 to 85 Vrms sine wave 76 Vrms for default Ring Voltage 2 sec on 4 sec off or 1 sec on 2 sec off optional for PLAR Loop Start DTMF pulse PLAR Battery Reverse Ground Start Metering pulse 12 KHz 16 KHz and P in PLAR mode PLAR signalling bits are programmable Programable bit e All in band signaling tones are carried transparently by the digitizing process e Customer is responsible for in band signaling compatibility between a telephone and a switch or between a PBX and a switch Application Illustrations Digital C O PLAR ON Loop 09500R X FXS Card Metering Pulse 12KHz 16KHZ x_x CO oe e D O Support Telephones line GND start Caller ID Modem Pay Phone Digital C O Loop 09500R Pulse Detect 12KHz 16KHz l am D Support pay Support phone GND start gt LOOP TELECOMMUNICATION INTERNATIONAL INC OOE LoopTelecom com ISO 900 1 150 1400 1 Worldwide Taipei Taiwan North America
16. 6KHz metering pulse option e A B C D signaling bit software programmable e Alaw or u law coding e Most signaling conventions supported e Mulfti color LED indicators for each port e Intended for use with 48Vdc powered main units Description 12 telephone connections for FXS e 12 central office or PBX line connections for FXO 12FXS 12FXO Voice Card for Loop O9500R ac 6 TULETEE eae Aii et i ii ir ee T Pa Daa i i i j oF pa 5 Yeye E f Ty E De t J 12 Channel FXO Card 12 Channel FXS Card The 12FXS 12FXO plug in cards are designed for the single slot of Loop O9500R It allows voice frequency interfaces to be multiplexed as a 64 Kbps DSO signal onto a digital network 12 FXS provides 12 voice Interfaces connect to telephones 12FXO provides connections from telephone lines either from a central office or from a PBX in RJ11X12 connector Coding is either A law or u law selectable by user Most popular signaling conventions are supported including PLAR Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Loop 0O9500 R 12FXS sn pt G Loop 0O9500 R 12FXS P sn pt G Loop 09500 R 12FXS M pt G Loop O9500 R 12FXS MPP pt G Loop 09500 R 12FXS GS pt G Description 12 channel FXS plug in card with 600 900 Impedance Battery Reverse PLAR
17. E E1 T1 DTE 8 bundles l l i I B IE Y ir Se ee oe ne oe _ _ a 16 bundles gt a a AA O9500R E1 T1 E1 T1 E1 TI DTE Voice E1 T1 DTE Voice AM3440 El Tl E1 T1 E1 T1 DTE Voice E1 T1 DTE Voice Ethernet Topology Link Bundle Circuit different color represents different bundle numbers AM3440 z LOOP TELECOMMUNICATION INTERNATIONAL INC mm PATA VA Telecom SRE ISO 9001 1SO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2011 Loop Telecommunication International Inc All Rights Reserved Version 4 25 OCT 2011 Subject to change without notice Telecom Features e PLAR supported e Loop start or Loop start ground start option e Battery reverse supported e DID supported e 12KHz and 1
18. MUNICATION INTERNATIONAL INC LoopTelecom com ISO 9001 1SO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 1 08 MAR 2009 Subject to change without notice es Dry Contact Interface Card for Loop O9500R Features e Two Dry Contact plug in card are available Dry Contact Dry Contact B Dry Contact Card Dry Contact type B card e Dry Contact Inputs 8 pairs per card 2 ports per card 4 pairs per port Connector RJ45 Collect dry contact input signals and send alarm traps via SNMP port or inband to LoopView EMS management system Collect dry contact to be transferred via the E1 or fiber optic cable to a dry relay contact output e Dry Contact Outputs 8 pairs per card Connector Screw Enable dry contact output signals through instructions via SNMP port or inband to LoopView EMS management system Enable dry
19. NI ISO 9001 1ISO 14001 LoopTelecom com Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 2 03 DEC 2009 Subject to change without notice DE V 35 X 21 V 36 RS449 EIA530 RS232 Interface Card for Loop O9500R Features e Maximum data rate of n x 64K n lt 32 e Mapping to any sequential time slots e Supports ANSI V 54 e Built in BERT for diagnostics Description The V 35 V 36 EIA530 RS232 X 21 plug in cards are a series of 4 different plug in cards designed for the dual slot of Loop O9500R They allow multiplexing of n x 64 Kbps data to multiples of DSO time slots onto a digital network An LED on the front panel of the Loop O9500R provides status indication Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the
20. air per card Screw type Min 1000M ohm at 500 Vdc 2A 220 Vdc 250 Vac When the alarm occurs this is detected by the dry contact input The dry contact card will send alarm trap to Control Center via SNMP port for management System Control Remote Command Dry Contact Control Outputs Point to Point Application Using both input and output dry contacts Using one DSO for alarm input and one DSO for alarm out put and vice versa When the alarm occurs it will send alarm trap via SNMP port for management Also the dry contact inputs at local site can be detected and transmitted to the dry contact outputs at the control site E1 T1 FOM Dry Contact Dry Contact Dry Contact Dry Contact Alarm Inputs Alarm Relay Port Control Alarm Panel Outputs Point to Multi Point Application Using the 16 DSO to carry the alarm input and alarm output 8 DSO for input 8 DSO for output and vice versa When the any of the assigned of the alarm occurs it will send alarm trap via SNMP port for management From the central management point all dry contact outputs can be controlled aS a _ Dry Contact Dry Contact Alarm Inputs Dry Contact Dry Contact Control Outputs Alarm Panel Dry Contact Dry Contact Alarm Inputs SE Dry Contact Dry Contact Alarm Inputs x Alarm Relay port Fe LOOP TELECOMMUNICATION INTERNA TIONAL INC YA
21. and a switch or between a PBX anda switch Application Illustration Loop 09500R Loop 09500R E1 T1 Switch EM E1 T1 E1 T1 EM Modem ELI ae PBX lt Microwave System Standard E amp M Interface Equipment Link or Tandem Connection LOOP TELECOMMUNICATION INTERNATIONAL INC Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2011 Loop Telecommunication International Inc All Rights Reserved Version3 28 MAR 2011 Subject to change without notice OOP G SHDSL Interface Card for Loop O9500R Features e Data rate of n x 64 Kbps n 1 to max n where max n 1 31 e Distances vary by line rate e Uses industry standard PAM line format e Software field upgradable e One LED indication per port e Two Port G SHDSL card supports 1 1 protection 2 channel G SHDSL 4 channel G SHDSL Description Loop Telecom s G SHDSL plug in card is designed for the Loop O9500R This card allows direct c
22. by the letter G appearing immediately at the end of the ordering code Model Description Note 7 Ports Fiber Optical Interface with 7 SFP housings This card can also be used in the Loop 09500 R FOM G SFP not included Loop 09400 R Accessories SFP Optical Modules Please place your order using the 5 digit alohanumeric codes listed in the separate SFP Optical Module Brochure User s Manual Loop O9500 R 7FOM UM User s Manual paper hard copy optional A CD version of the manual is already included as standard package Product Specifications Fiber Optical Interface Port number 7 Source Laser Line Code Scrambled NRZ Wavelength 1310 50 nm 1550 40 nm Optical Line Rate 38 84Mbps Connector SFP housing with LC type Reach 2 240 Km please refer to the SFP brochure for detail Protection 1 1 Line Protection Optical Fiber Interface Characteristics Pleaer refer to SFP optical brochure for detail Diagnostics Test Optical Fiber E1 Test Pattern Local and remote loopbacks To optical direction or backplane direction Application Illustrations Point to Point FOM Other Controller a cards Card hani 09310 E1 Fiber Optical 09500R Cable E1 E1 FOM FOM Other Controller Controller Other a cards Card JI Piao Pink Card cards lt gt Datal D Fiber Optical P Voice O9500R AM3440 1 1 Line Protection FOM Card 1 l4 Working h Working FOM Card 1 Port 1 Port 1 09500R Port alles
23. com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 1 03 MAR 2009 Subject to change without notice
24. digitizing process Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Description Note ROHS compliant Loop 09500 R 12MAG 1G x G 12 channel Magneto plug in module w L1 GND Loop 09500 R 12MAG 12 x G 12 channel Magneto plug in module w L1 L2 12MAG 1G2 includes all Loop 09500 R 12MAG 1G2 x G 12 channel Magneto plug in module w L1 L2 and L1 GND function of 12MAG cards Loop O9500 R 12MAG A 1G x G 12 channel Magneto ring one time plug in module w L1 GND Loop O9500 R 12MAG A 12 x G 12 channel Magneto ring one time plug in module w L1 L2 12MAG A 1G2 includes Loop 09500 R 12MAG A 1G2 x G 12 channel Magneto ring one time plug in module w L1 L2 all function of 12MAG A and L1 GND cards Accessories User s Manual Loop 0O9500 R 12MAG UM User s Manual paper copy Note A CD version of the manual is already included as standard package m Where x is used to select version type Description Note 16 16 Hz ring generator 20 Hz is the general setting for all MAG 20 20 Hz ring generator cards For special settings 16 25 50 25 25 Hz ring generator please specify your need by filling in the x 90 50 Hz ring generator option Magneto Interface Card Product Specifications Magneto old crank handle hot line telephones MRD Manual Ring Down Voice Card Connector Alarm Conditioning Encod
25. ditioning Encoding AC Impedance Longitudinal Conversion Loss Cross talk measure Gain Adjustment Signal Distortion Frequency Response Idle Channel Noise Variation of Gain FXO FXS Loop Feed FXS signalling FXS Ringing Signaling Optional Signaling for special order Signaling Bit A B C D Twelve RJ11 CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable together for all Balanced 600 or 900 ohms selectable together for all gt 46dB Max 70dBm0 21 to 10 dB 0 1dB step transmit amp receive gt 25dB with 1004 Hz OdBm input 0 25 to 1 dB from 300 to 3400 Hz coincide with ITU T G 712 Max 65 dBm0p 0 5dB Ringing REN 0 5B AC Detectable Ringing 25 Vrms Loop Resistance lt 1800 Q DC Impedance ON HOOk gt IMO DC Impedance OFF HOOK 235 O 25 mA feed 90 O 100 mA feed 48Vdc with 25mA current limit per port Jumper Selectable 25mA 30mA 35mA Normal Automatic Ring down 1 REN at 5K meters per port 16 7Hz 20Hz 25Hz 50Hz user selectable for all ports 38 to 85 Vrms sine wave 76 Vrms for default Ring Voltage 2 sec on 4 sec off or 1 sec on 2 sec off optional for PLAR Loop Start DTMF pulse PLAR Battery Reverse Ground Start Metering pulse 12 KHz 16 KHz and P in PLAR mode PLAR signalling bits are programmable Programable bit e All in band signaling tones are carried transparently by the digitizing process e Customer is responsible for in band signaling compatibi
26. eiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version v1 08 MAR 2009 Subject to change without notice ZA a Yaw a Vl wavasa 7 Fiber Optical Interface for Loop O9500R Features e Hot pluggable high speed interface card for O9500R IMAP e Aggregate ports e 7 aggregate ports with SFP housing each supports 4 E1s e Port Protection e Line 1 1 requires two cards e Switching time within 50ms e Automatic Laser Shutdown ALS function e Single mode and multi mode fiber modules e Local and remote FOM alarm indication g Description The Loop O9500R 7 FOM card is a high speed module that can connect with the AM3440 series and Loop 09310 E1 using Loop proprietary FOM interface Each card has 7 FOM interfaces Each FOM interface supports up to 4 E1 aggregate channels The 7 FOM card is E1 mode configurable and supports Tributary Line 1 1 Protection When protection enable with 1 1 the O9500R can support up to 14 ports of FOM Ordering Information Note RoHS compliant unit is identified
27. end of the ordering code Model Description Note ROHS compliant Loop O9500 R 6X21A G 6 channel X 21 V 11 card with DB15 connector These cards will occupy two slots These cards can also be used in Loop O9500 R 6V35A G 6 channel V 35 plug in card with DB25S connector for the Loop AM3440 A BIC M34 2Mbits per channel Please order conversion cable connector below Loop O9500 R 6V36A G 6 channel V 36 card with DB25 connector via conversion cable to DB37 Loop O9500 R 6E530A G 6 channel EIA530 plug in card with DB25 connector Loop O9500 R 6RS449A G 6 channel EIA530 RS449 plug in card with DB25 connector via conversion cable to DB37 Accessories Conversion Cables All conversion cables are ROHS compliant Loop ACC CAB DB25M 30 DSUB 25pin Male to M34 Female V 35 Conversion cable Used in 1M34F Length 30 cm Loop 0O9500 R 6V35A G plug in card Loop ACC CAB DB25M 30 DSUB 25pin Male to DSUB 37 Female RS449 Conversion Used in 1DB37F cable Length 30 cm Loop 0O9500 R 6V36A G and Loop O9500 R 6R449A G plug in cards User s Manual Loop O9500 R DTE UM User s Manual paper copy Note A CD version of the manual is already included as standard package Product Specifications for DTE Interface Cards DTE X 21 V 11 Interface 6X21A Data Port Up to six 6 port DTE X 21 card 1 port DTE X 21 card future option Data Rate 56 or 64 Kbps n 1 to 32 Connector DB15 DTE V 35 V 36 Interface 6V35A 6V36A Data Port Up to six 6 port DTE
28. ic Test G SHDSL Loopback To LINE To bus BERT QRSS Application Illustration J 200Kbps 2056 Kbps avs LOOP TELECOMMUNICATION INTERNATIONAL INC mm PATA YS LoopTelecom com ISO 900 11SO 1400 1 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2009 Loop Telecommunication International Inc All Rights Reserved Version 1 08 MAR 2009 Subject to change without notice LS Fiber Optical Interface for Telecom Loop O9500R Features e 4 1 port per card single slot to O9500R e Supports data rates up to 12x64kb e Provide multi color LED indicator e With ALS Automatic Laser Shutdown Description The LS Fiber Optical plug in card is designed for slots 11 16 of Loop O9500R as embedded 1 or 4 C37 94 low speed optical interface This plugged in card can be used to aggregate 1 12 DSO channels to single fiber optical interface to connect with other Loop O9500R device or C37 94 Modem Orderi
29. ing Impedance Longitudinal Conversion Loss Gain Adjustment Signal Distortion Frequency Response Idle Channel Noise Signaling Minimum Detectable Ringing Voltage Crank Detectable Across Crank Detected time Ringing Generation Ring duration Ringing Send Across Signaling Signaling Bit A B C D RJ11 x 12 CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable together for all Balanced 600 or 900 ohms for magneto telephone impedance gt 46dB 21 to 10 dB 0 1dB step transmit amp receive gt 25dB with 1004 Hz OdBm input 0 25 to 1 dB from 300 to 3400 Hz coincide with ITU T G 712 Max 65 dBm0p 16 Vrms L1 amp L2 Mode Tip and Ring L1 amp GND Mode Tip and GND Valid carnk more than 250 ms Invalid crank less than 160 ms Voltage 76 Vrms sine wave Frequency 20Hz with optional choices of 16 25 50 Hz Two optional modules are available for your choice 1 12MAG Normal operation Ring duration depends on cranking time PLAR ON operation when FXS pone off hooked the ring duration of the far end magneto phone could be 0 5 1 0 2 0 or 4 0 sec 2 12MAG A Normal operation Crank the phone for one time and the ring duration of the far end phone could be 0 7 1 5 or 2 0 sec PLAR ON operation when FXS phone off hooked the ring duration of the far end magneto phone could be 0 7 1 5 or 3 0 sec L1 amp L2 Mode Tip and Ring L1 amp GND Mode Tip and GND Turn Magneto Phone cran
30. its and reverse bit channels S4 Disable the function of the test button S5 Forcing all ports to be OFF HOOK when an alarm occurs S6 Forcing all ports to be ON HOOK when an alarm occurs Note For S customer s special bit please refer to SFP brochure or contact your nearest Loop sales representative Product Specification for E amp M Interface Card Connector Eight RJ45 Alarm Conditioning CGA busy after 2 5 seconds of LOS LOF Encoding A law or u law user selectable together for all Impedance Balanced 600 or 900 ohms Longitudinal Conversion Loss gt 46dB Longitudinal Balance gt 638dB Gain Adjustment Per port setting 10 to 7 dB 0 1dB step for transmit D A gain 10 to 14 dB 0 1dB step for receive A D gain I O voice power range A D digital input level 66 dBm 0 00039 Vrms 3 dBm 1 09 Vrms D A analog output level 66 dBm 0 00039 Vrms 7 dBm 1 74 Vrms Signal Distortion gt 25d0B with 1004 Hz O0dBm input Frequency Response 0 5 to 0 9 dB from 300 to 3400 Hz Carrier connection Side A exchange side and Side B carrier side setup by side switch Idle Channel Noise Max 65 dBm0p wire mode 2 wire and 4 wire programmable Signaling Type 1 Type 2 Type 3 Type 4 and Type 5 Transmit only programmable Modems Full compatibility with V 90 modems All in band signaling tones are carried transparently by the digitizing process Customer is responsible for in band signaling compatibility between a telephone
31. k Ringing across Tip and Ring or Tip and Ground Programable e Signaling is carried transparently by the digitizing process e Use Magneto card default setting for communications between magneto telephones e Use Magneto card PLAR mode setting for communications between a magneto telephone and a regular telephone Application Illustrations Loop O9500R E1 T1 MAG ae Card Card Magnet Phone Loop 09500R MAG E1 T1 Card Card MRD Standard Magneto Phone to Magneto Phone Loop 09500R E4 T1 MAG Card Card PLAR Mode Loop O9500R FXS E1 T1 Card Card standard ji Phone PLAR Mode Magneto Phone MRD Note The Magneto card in both figure 1 1 and 1 2 support two ring duration types MAG or MAG A For detailed information please refer to Specification Telephone to Hand cranked Magneto Phone LOOP TELECOMMUNICATION INTERNATIONAL INC W WAVAVI VA LoopTelecom com ISO 900 11SO 1400 1 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom c
32. lity between a telephone and a switch or between a PBX and a switch Application Illustrations Digital C O PLAR ON oop 09500R FXS Card Metering Pulse 12KHz 16KHz CO Support Telephones Pay Phone line GND start Caller ID Modem Digital C O Loop 09500R Pulse Detect 12KHz 16KHz 6 l lt _ x S Support pay Support phone GND start gt LOOP TELECOMMUNICATION INTERNATIONAL INC me WAA TE Loop Telecom com ISO 900 TSO 1400 1 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 300 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2012 Loop Telecommunication International Inc All Rights Reserved Version 5 21 MAR 2012 Subject to change without notice 7 24 FXS FXO Voice Card for Loop O9500R Features 24 telephone connections for FXS 24 central office or PBX line connections for FXO PLAR supported Loop start or Loop start ground start option Battery reverse supported DID supported
33. ludes all FXO card Used with 12 RJ11 functions Loop 09500 R 12FXO M G 12 channel FXO plug in card with 600 900 Impedance Battery Reverse Loop Start and 12FXO GM includes all FXO Card Metering Pulse Used with 12 RJ11 functions Loop 09500 R 12FXO GS G 12 channel FXO plug in card with 600 900 Impedance Battery Reverse Loop Start and 42FX0O x cards with H W ver G and Ground Start Used with 12 RJ11 F W V2 01 01 or newer versions It can Loop 09500 R 12FXO GM G 12 channel FXO plug in card with 600 900 also be used in the AM3440 A B C Impedance Battery Reverse Loop Start Ground Start and Metering Pulse Used with 12 RJ11 Accessories User s Manual User s Manual paper copy Loop O9500 R FXSFXO UM Note A CD version of the manual is already included as standard package For 12 channel FXS Card E Where sn is used to select special function If this option is not required omit the sn field in the ordering code sn Description Note Si FXS Loop Feed 48 Vdc with 35 mA current limit S4 Remove alarm tone S5 Double ring tone transmit Note For sn special function please contact your nearest Loop sales representative E Where pt is used to select the following functions pt Description Note PWR complied with 48 Vdc SD48 power modules PWRIE1613 complied with IEEE1613 standard and with 48 Vdc SD48 power modules 12FXS FXO Product Specifications Voice Card 12FXS 12FXO Connector Alarm Con
34. ng Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Description Note Main Unit Loop O9500 R 1C37 G 1 channel C37 94 plug in card These cards can also be used in the Loop AM3440 A B C Loop O9500 R 4C37 G_ 4 channel C37 94 plug in card Accessories User s Manual Loop 09500 R C37 UM Optional hard copy paper User s Manual A CD version of the manual is already included as standard equipment Product Specifications for LS Fiber Optical Interface Card C37 94 Interface 1 4C37 Source LED Wavelength 820nm 2Km reach Connector ST Optical Budget 50 Mircon core 9 6 db 62 5 Mircon core 15db Application Illustration e eeeaeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eae e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eae Central Office T1 E1 Loop 09500R Protective Relay Customer Site r eo enoenoeoooanoaoeoeoononoanonanonen Se CA AA AA AYA YA YA YA UA AA YA UA AA AA UA YA YA UA UA AA AA AA AA AA Ed AA AA AA AA AAA AAA AA UA AAA AA AA AA AAA AA AAA AA AAA AA AAA AA AAA CA AA AA AA AA AA AA AA 4 S eaeaeaeeeeeeeeeeeeaee G AA e f eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee Protective Relay S eeaeeeeeeeeeeeeeeeeeecee YA Loop 09500R LS Optical Network Service Provider 92 1 1 1 1 1 1 1 0 0 1 r h 1 1
35. nication International Inc All Rights Reserved Version 2 28 MAY 2010 Subject to change without notice G 703 Interface Card for Loop O9500R Features 8 port G 703 plug in card single slot to O9500R chassis e Support data rate at 64 Kbps e Support G 703 transmission over balanced wire e Eight LED indications per card Description The G 703 plug in card is designed for the single slot of Loop O9500R This interface supports 64 Kbps data transport using the G 703 co directional timing standard The G 703 plug in card supports diagnostics and alarm setup using a local or remote terminal connected to the main unit This allows in service diagnostics and fault isolation Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Model Description Note Loop O9500 R 8CD G 8 channel G 703 plug in card at 64 Kbps data This card can also be used in the rate Loop AM3440 A B C Accessories User s Manual Loop O9500 R 8CD UM User s Manual paper copy Note A CD version of the manual is already included as standard package Product Specifications for G 703 Interface Card Interface ITU G 703 64 Kbps co directional interface Connector 1200hm RJ48 Line Distance Up to 500 meters Loopback DTE Payload Loopback Local Loopback Application Illustration G 703 64Kbps WAN LOOP TELECOM
36. om michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw All Rights Reserved 2011Loop Telecommunication International Inc Subject to change without notice Version 1 09 MAR 2011 FE Router B Interface Card for Loop 09500R Features Eight ports of 10 100BaseT interfaces Auto MDI MDI X crossover Routing Protocol RIP I RIP II OSPF Open Shortest Path First and static route Remote Software Upgradeable Supporting Protocols PPP MLPPP HDLC Frame Relay and Cisco compatible HDLC VLAN ID mapping Up to 64 WAN ports with aggregate data rate of 8 Mbps Remote bridge support padding un padding Ethernet FCS Support of QoS Quality of Service Description The Router B plug in card is designed for the single slot of Loop O9500R When used within the Loop O9500R this card combines the function of a router and directs Ethernet traffic to from multiple WAN channels With this card access from LAN to WAN is accomplished within one card resulting in savings in cost and in space Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Model Description Note ROHS compliant Loop O9500 R RTB G 8 LAN port 64 WAN ports router bridge plug in card This card can also be used in the Loop AM3440 A B C Accessories User s Manual ji mn f User s
37. onnection to wire pairs using 16PAM transmission technology Versatility of this card comes from the choice of data rates with the lower data rates applicable to longer reaches The G shdsl plug in card can work with Loop H 3300 38 and is compatible with other G SHDSL equipment The G SHDSL plug in card supports configuration and diagnostics using a local or remote terminal connected to the main unit This allows in service diagnostics and fault isolation Ordering Information To specify options choose from list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Model Description Note Loop O9500 R 2GH G 2 channel G SHDSL plug in card 2 pair This card can also be used in the Loop AM3440 A B C Loop 09500 R 4GH G 4 channel G SHDSL plug in card 1 pair This card can also be used in the Loop AM3440 A B C Accessories User s Manual User s Manual paper copy BOOP ao eine Note A CD version of the manual is already included as standard package Product Specifications for G SHDSL Interface Card G shdsl Line Interface 2GH 4GH Number of ports 2or4 Line Rate for 4 channel G shdsl n x 64Kbps n 3 to 31 Line Rate for 2 channel G shdsl n x 64Kbps n 3 to 15 Line Code 16 TCPAM full duplex with adaptive echo cancellation Connector RJ45 Electrical Unconditioned 19 26 AWG twisted pair Sealing current Max 20 MA source current Clock Source From System Line Diagnost
38. ontact I O plug in card These cards can also be used in the Loop AM3440 A B C Loop O9500 R 8DCB G 8 channel dry contact type B plug in card with maximum voltage 220 Vdc or 250 Vac Accessories User s Manual All User s Manuals are RoHS compliant Loop 0O9500 R 8DC UM Optional hard copy paper User s Manual A CD version of the manual is already included as a standard package Product Specifications for Dry Contact Card Dry Contact I O card 8DC Inputs 8 channel 2 port per card 4 pair per port Connector RJ45 Internal Resistance 1K Activation Current 3 ma Deactivation Current 1 5ma Allowable Current 4ma Dry Contact Type B Interface Inputs 8 channel 2 port per card 4 pair per port Connector RJ45 Internal Resistance 100 K Activation Current 3 ma Deactivation Current 1 5ma Allowable Current 4ma Application Illustrations Outputs 8 channel Connector Initial Insulation Resistance Max Current Max Voltage Outputs 8 channel Connector Initial Insulation Resistance Max Current Max Voltage Dry Contact Input Application SNMP Trap System Control SNMP Trap Dry Contact Dry Contact Control Outputs Dry Contact Dry Contact Output Application Remote Contact Control From the Control Center any dry contact can be made to close by remote commands Dry Contact 8 pair per card Screw type Min 100M ohm at 500 Vdc 5A 100 Vdc 250 Vac 8 p
39. ps z Description The 8RS232 Interface Card for Loop O9500R has 8 interface ports For the RJ version 8 RJ48 connectors are available in Asynchronous mode only For the DB version 2 RJ48 provide 2 ports and 2 DB44 connectors provide 3 ports each Two cables are included Each cable converts from DB44 connector to two DB25 and one DB9 connectors For Asynchronous signals the card can be used in either INDEPENDENT mode or MUX mode In the INDEPENDENT mode each of the 8 Asynchronous ports up to 38 4 Kb s rate is assigned a separate 64 Kb s channel In the MUX mode up to 5 ports each up to 9 6 Kb s can share a single 64 Kb s channel The rest 3 ports will be multiplexed to another 64Kb s channel For Synchronous signals only four of the ports can be used leaving another 4 ports as Asynchronous In the INDEPENDENT mode each of the 4 Synchronous ports can be up to 64 Kb s The rest of the 4 Asynchronous ports each up to 38 4 Kb s rate is assigned a separate 64 Kb s channel per port In the MUX mode the 4 Synchronous ports each up to 9 6 Kb s share a single 64 Kb s channel The other 3 Asynchronous ports will be multiplexed to another 64Kb s channel The 8RS232 Interface Card uses the multiplexing format defined in ITU T X 50 Div 2 and in X 54 for rates below 64kbps For 64kbps transport standard RS232 format is used In the INDEPENDENT mode when only one subrate signal is transported the unused bandwidth is filled with 1s Ordering
40. ransport of TDM signals E1 T1 Jitter and Wander adheres to G823 Traffic and G823 Synchronous Ordering Information Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Description Note ROHS compliant Loop O9500 R TDMoE PPM G Accessories User s Manual Loop O9500 R TDMoE UM SFP Optical Modules TDMoE card with 2 GbE combo interfaces and 2 Ethernet interfaces 10 100 1000BaseT plug in module Support G 823 Traffic User s Manual paper copy Note A CD version of the manual is already included as standard package Please place your order using the 5 digit alohanumeric codes listed in the separate SFP Optical Module Brochure TDMoE for Loop O9500R Product Specifications Optical SFP Module Characteristic please refer to SFP optical module brochure for detail Combo Gigabit Ethernet GbE Interface Number of Ports Speed Connector 2 10 100 1000M bps RJ45 for twisted pair GbE LC for optical GbE auto detection Gigabit Ethernet GbE Interface Number of Port Speed Connector Ethernet Function Basic Features Packet Transparency Jumbo Frame QoS Traffic Control Link Aggregation Jitter amp Wander PPM per G 823 Traffic Standard Compliance 2 10 100 1000 BaseT RJ45 MDI MDIX for 10 100 1000M BaseT auto sensing Ping function contained ARP Per port programmable MAC hardware address learn limiting max MAC table 8192 8k
41. s will occupy two slots Loop O9500 R 24F XS M pt G 24 channel FXS plug in card with 600 900 These cards can also be used in the Impedance Battery Reverse Loop Start PLAR and Loop AM3440 A B C Metering Pulse Loop O9500 R 24FXS MPP pt G 24 channel FXS plug in card with 600 900 Impedance Battery Reverse Loop Start PLAR F ti foarte th PLAR bit programmable and Metering Pulse OFS OPHON T P a me s S Loop 09500 R 24FXS GS pt G 24 channel FXS plug in card with 600 900 table below for detail information Impedance Battery Reverse Loop Start PLAR and Ground Start Loop 09500 R 24FXS GM pt G 24 channel FXS plug in card e with 600 900 pt power type Impedance Battery Reverse Loop Start PLAR Ground Start and Metering Pulse Loop O9500 R 24FXS GMP pt G 24 channel FXS plug in card with 600 900 Impedance Battery Reverse Loop Start PLAR table below fro detail information PLAR bit programmable Ground Start and Metering Pulse Loop O9500 R 24FXO pt G 24 channel FXO plug in module with 600 900 Impedance Battery Reverse without Ground Start and Metering Pulse 24FXS GMP includes all FXS card For pt option please refer to the Loop O9500 R 24FXO M pt G 24 channel FXO plug in module with 600 900 Impedance Battery Reverse Metering Pulse 24FXO GM includes all FXO card Loop O9500 R 24FXO GS pt G 24 channel FXO plug in module with 600 900 functions Impedance Battery Reverse Ground Start Loop O9500 R 24FXO GM pt G
42. supported Type 1 H Type 2 Type 3 Type 4 and Type 5 HHS e Programmable gain setting per port adi e Aside and B side supported A side is exchange side B side is carrier side e 2 wire 4 wire supported e Transmit only TO type supported e law or u law coding e Intended for use with 48Vdc powered main units 2 Description Loop Telecom s E amp M plug in card is designed for the Loop O9500R device It allows 8 ports E amp M interfaces to be multiplexed to 64 Kbps DSO signals It can also be used as TO Transmit Only Voice coding can be selected as either A law or u law This unit can be used on systems running 48Vdc power supply Ordering Information To specify options choose from list below Model Description Note ROHS compliant Loop 0O9500 R 8EM x G 8EM card with H W ver F and later versions F W 8 channel 2W 4W E amp M plug in V4 01 01 and later versions can also be used in the Loop card AM3440 A B C For x option please refer to the table below Accessories User s Manual User s Manual paper copy EDO OE BENT Note A CD aa of ean is already included as standard package E Where x is used to select signaling bits type and special functions 8EM x Description Note E Follows ETSI signaling bits A Follows ANSI signaling bits R Reverse for ON HOOK and OFF HOOK signaling bits exchange S Follows customer s special bit or function assignment Jumper selectable for all AR Follows ANSI signaling b
Download Pdf Manuals