Home
Double Electric Breast Pump
Contents
1. 4 d oc 4 PAN Napoca ND T NE 6 Liz currus E Y eee 7 Expression Collection Combo Kit P rE ETETEN NE 8 How to Assemble the Expression Collection Kit cccssccccssecccseeeceececeeeecseeeecseeesaesesseeeses 9 How to Assemble Electric Pump Diaphragm Kit cccccesceceececeeseeceeseeceneeseeseesseeesgeessageess T2 How to Assemble Expression Collection Combo Kit ccccceeccceseeceeseeceeceseseessseesseeessaeeess 13 e i Mee RTT m RTT 15 Using your AC DC Adapter INC E 15 e Using 4 AA Alkaline Batteries Batteries not included Luiuuusssssssesese nemen meme nemen nere nere 16 Install the Batteries AA AIKaline 17 Ive ped ME VUCIONS errin e EET UT 19 CS ANI MNS RNC TINS NER RR E m UT 22 Sanitize Prior to First USG M m 22 A E E E E se pen sp E E E E E E E EE 22 LEc a cae uas d 22 T bing Cleaning SMO M CE Q 23 Breastmilk Storage GUNGSIINGS akcixata teiE tator uai Eu obtu utu va edd rented uc o UM ER uda t ui c iEn 24 Important Notes eso tates RR RNC 24 TDS bese ee 26 PUMPING TIPS peace cc RR
2. 26 e Breastfeeding Tips ax annae 27 Wieso VINNY aer a E E E E E E 28 e Interruption of Electrical Service 28 Radio Frequency EDS cussstaxereieDiersteieitixervrDet Festes N Ene EE butt rE r REOPEN EEEE EnA PUEIS EEEE VU Cw i EEEN ETEA 28 Decreased SUCtHON eae nc or eo E Rea oe CRT PO E ETE E RO OE ee ee 28 e Breastmilk Buildup in the Breastshield Body ccccceccecceceecceccueccucceceeceeceucecaeaueaecceeeeceueeeueaueeeaceauavaues 29 Pumping Doesnt Stant a geass is ieee st eee ic test ce ce cig os es ci cde tele teeta 29 e Where to get Replacement Parts c cccccccecececececuceceececececececucucueaeneaececececueueaeaeaeaesesececucuceeaeaeaenenenenes 29 e What Additional Accessories are Available essssssesseee nemen emen rnern Eran he mne insere EErEE re renes 29 Technical Data ETC 30 Power Requirements aceasta erer EE eneore baa deal e erae ede EEE Ero ndndubq sess EAEE EEn 30 rur E E E E EE E E A E E A A E EN tein tasvand ooabieineen 31 Important Safeguards The Viverity Tr Comfort Electric Breast Pump is designed for a single user and should never be shared or resold doing so will void the warranty READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce the risk of electrocution e Always unplug this product immediately after using e Do not use while b
3. Civerty TRU comfort live life wel Double Electric Breast Pump with collection combo kit User Manual Model ROS DBEL Congratulations Congratulations on your new Viverity Tr Comfort Electric Breast Pump The Viverity Tr Comfort Electric Breast Pump is perfect for many occasions e Collecting breast milk while you re away from your baby o for example when you re at work e Relieving engorgement o for example when your baby s feeding habits change because they re eating more solids e Maintaining your milk supply if you have to temporarily stop breastfeeding o for example to express unsuitable milk while you are undergoing medical treatment The Viverity Tr Comfort Electric Breast Pump provides many of the features busy moms love e 4 speed modes and levels of suction e Milk back flow protection e Quiet motor for discretion e Small and lightweight e 2 power options to fit your needs o AC DC Adapter o 4 AA Alkaline batteries not included Indication for Use The Viverity Tr Comfort Electric Breast Pump is a single user electrical powered device used to express milk from the breasts of lactating women This device is not intended for hospital use Table of Contents CONAS EON RR SE E ETA r 1 gts fore hi og 91 9 GW Lc eee nee ene E EE E E E E A ee E 1 gel alos cc piers iicts Urs TETTE TE ee eee T 4 o cc aes ores chess sn cc ec stag ac a cet ge eect oc so E elon are TE 4 TRON a8 oars
4. turn the pump off by pressing the Power Button U l Note Make sure there is no suction on the nipples before removing the Breastshield If necessary break the suction by inserting a finger between the Breastshield and the breasts similar to the way you break away from your baby s suction C ec Note If the Viverity Electric Breast Pump is left on but unattended for more than 30 minutes the Pump will automatically shut off 21 Cleaning Instructions Unless otherwise instructed by your healthcare provider follow these sanitizing and cleaning instructions Sanitize Prior to First Use Before you use your Viverity Electric Breast Pump for the first time disassemble and boil all parts of the Expression Collection Combo Kit in water for 10 minutes e Be sure to use enough water to keep all parts afloat while boiling e Do NOT boil Tubing or Tubing Adapter e Remove all parts from the water immediately after sterilizing To avoid scalds and burns do NOT touch the product with bare hands right after sterilizing e Completely air dry or towel dry before reassembling for next use Partially dry components may affect the operation of your Electric Breast Pump Please ensure that all parts are completely dry before use Before Each Use e Wash your hands thoroughly with soap and warm water before handling the Electric Breast Pump or any Expression Collection parts or attachments e Make sure all parts are clean and dry e E
5. running under warm water for several minutes ALWAYS test the temperature of the milk on the inside of your wrist before feeding it to your baby The milk should feel warm not hot e WHAT TO DO Storing milk in 2 to 4 oz amounts may reduce waste Write the date you expressed your milk on the container include your baby s name on the label if your baby is in a daycare setting Use the oldest milk first Throw away previously frozen milk that is not used within 24 hours e WHAT NOT TO DO Do NOT heat milk directly on the stove Do NOT thaw in hot or boiling water Do NOT microwave milk as microwaving alters the composition of the milk and may create hot spots that may burn your baby Do NOT refreeze thawed milk e NOTE Human milk may separate into a milk layer and a cream layer when it is stored This is normal Gently swirl to redistribute the cream before giving to baby Sometimes thawed milk may smell or taste soapy This is due to a breakdown in the milk fats The milk is safe and most babies will still drink it e STORAGE Expressed milk can be kept in a common refrigerator at the workplace or day care center The US Center for Disease Control CDC and the US Occupational Safety and Health Administration OSHA agree that human milk is not among the body fluids that require special handling or storage in a separate container 24 Breastmilk Storage Guidelines Continued 39 F or colder Refrigerator O F or colder Smaller cooler
6. with a blue ice pack Room temp 60 F 85 F Countertop table e Up to 72 hours is best e Up to 5 8 days is okay for very clean expressed milk e Up to 6 months is best e Up to 12 months is okay 24 hours e Up to 3 4 hours is best e Up to 6 8 hours is okay for very clean expressed milk Store milk in the back of the main body of the refrigerator Store milk toward the back of the freezer where temperature is most constant Milk stored at O F or colder is safe for longer durations but the quality of the milk might not be as high Keep ice packs in contact with milk containers at all times limit opening cooler Containers should be covered and kept as cool as possible covering the container with a clean cool towel may keep milk cooler Throw out any leftover milk within 1 to 2 hours after the baby is finished feeding CAUTION Do not refreeze thawed milk Discard any remaining thawed milk if not used within 24 hours Source Breastfeeding Made Easier at Home and Work www womenshealth gov 25 Pumping Tips The most important and successful part of pumping is the let down reflex The let down reflex is when your milk begins to flow freely e Try relaxing with a warm wet compress on your breasts e Drink plenty of fluids e Avoid outside distractions e Visualize yourself happy well rested and successful at pumping e Sometimes a light circular massaging of the breasts prior to and or during a p
7. LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO REPLACEMENT COSTS RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANT Y 31 Warranty Continued If you wish to make a claim under this warranty please contact your local DME dealer retailer where you purchased the unit from You will need the following information when making your claim e The entire original Viverity product and packaging e he original receipt showing date of purchase e Detailed description of the problem 32 VIVERIT Y live life well Manufactured for C OMscor Roscoe Medical Inc 21973 Commerce Parkway 9g Better Living Strongsville OH 44149 USA
8. Tips e The Viverity Electric Breast Pump helps you maintain a supply of milk and can help you prepare for planned events such as Date Night or unexpected events such as power outages medical treatment or relief from tender nipples 27 Troubleshooting Interruption of Electrical Service If you experience an interruption of electrical service due to a power surge or other factors during normal operation of your Viverity Electric Breast Pump try the following e Unplug the AC DC Adapter cord from the electrical outlet and wait for five seconds before plugging the AC DC Adapter cord back into the electrical outlet e Try a different electrical outlet in another room or on a different circuit Radio Frequency Energy This equipment generates uses and can radiate radio frequency energy If not installed properly and used in accordance with the instructions it may cause harmful interference with other devices in the vicinity Try the following e Reorient or relocate the device receiving interference e Increase the distance between the equipment e Connect the equipment into an outlet on a different circuit from that which the other device s are connected e Consult the manufacturer or a field service technician of the device receiving interference for help e There is no guarantee that interference will not occur Decreased Suction If it feels like the suction has decreased try the following e Make sure the Expression Colle
9. Way Valve when twisting the Breastshield Body and the Bottle Adapter pieces together If you bump the One Way Valve repeat step 3 10 How to Assemble the Expression Collection Kit Continued 5 With the Bottle Adapter in one hand twist on the Collection Bottle for a secure fit How to Assemble Electric pump Diaphragm Kit 1 With the Cup in one hand place the Diaphragm in the Cup matching the shape of the Cup Press around the edges of the Diaphragm for a secure fit Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them 2 Place the Cap on the Cup amp Diaphragm Be sure to align the hinge and hinge cover Press tightly to seal Hinge cover 12 How to Assemble the Expression Collection Combo Kit 1 With the O Ring side down put the Electric Pump Diaphragm Kit into the top of the Breastshield Body opening Twist the Electric Pump Diaphragm Kit clockwise into the Breastshield Body until it locks into place Turn Clockwise 2 Take the open end of Vacuum Tubing the end without the adapter and connect to the Tubing Connector located on the Cap Push together firmly for a tight seal Note Make sure there is no moisture in the Tubing Tubing Connector How to Assemble the Expression Collection Combo Kit Continued 3 With the Breastshield Body in one hand place the Silicone Cushion in the Breastshield Body matching the shape of the horn Secure the lip of the Cushi
10. athing e Do not place or store this product where it can fall or be pulled into a tub or sink e Do not place or drop into water or other liquid e Do not reach for an electrical product that has fallen into water Unplug immediately CAUTION e Do not use this product for any other purpose than as indicated in the Instructions and Assembly e Make sure all the parts are assembled correctly before operating e Stop using the breast pump immediately if your breasts or nipples experience any discomfort e Please wash hands before using this product e Keep this product out of reach of babies and children e Do not drop or hit the product to avoid damage e Do not touch the product with bare hands right after sterilizing by boiling water to avoid scalds and burns e Do not over boil to avoid premature aging of the product materials WARNING To reduce the risk of burns electrocution fire or injury to persons e his product should never be left unattended when plugged in e Close supervision is necessary when this product is used near children or invalids e Use this product only for its intended use as described in this manual Do not use attachments or parts not recommended by Viverity e Do not operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or if it has been dropped in water e Keep the cord away from heated surfaces e Do not use while sleeping or drowsy e Do n
11. ction Combo Kit is assembled correctly see pages 9 14 o Inspect the One Way Valve for any tears or pinholes This component is critical to achieving proper suction If damaged replace the One Way Valve with one of the spare valves that is provided with your Viverity Electric Breast Pump e Detach the Tubing and Tubing Adapter from the back of your Electric Breast Pump and place a finger over the Tubing Adapter Inlet o If you do feel suction the Electric Pump Base is operating properly o If you do NOT feel suction or feel that the suction has decreased to an unexpected strength contact your local DME dealer retailer where you purchased the unit from for warranty service see Page 31 28 Troubleshooting Continued Breastmilk Buildup in the Breastshield Body If breastmilk doesn t appear to be draining fast enough into the Collection Bottle reduce the suction setting on your Electric Breast Pump to allow the milk to drain before gradually increasing Pumping Doesn t Start e Make sure the adapter is properly plugged e f you are using the battery make sure the battery is fully charged eWhen battery runs low power button LED flashes and then turn off automatically Where to get Replacement Parts If you are missing a part or need a replacement part please contact your local DME dealer retailer where you purchased the unit from Additional Accessories Parts Part Number e Bottle Set 6 sets ROS BOTTLESET e Si
12. ent regulations for environmental protection and recycling Note Alkaline Batteries may present a risk of fire or chemical burn if mistreated Do NOT disassemble any battery Do NOT place batteries near heat source or fire Dispose of used batteries properly Do NOT dispose of batteries in fire Keep away from children Install the Batteries AA Alkaline 1 Open the Battery Cover Install the Batteries AA Alkaline Continued 3 Insert 4 new AA Alkaline Batteries Note Make sure the polarity is correct as indicated Pumping Instructions 1 Hold the Expression Collection Kit to your breast so that your nipple is centered inside the Breastshield qu Note Please check for correct fitting of the shield Pumping Instructions Continued 3 Start pumping with T1 speed T1 LED on top panel lights up 4 If you prefer a different pumping speed just press the Expression Button to switch between 4 different speed modes Suction speed gradually slows down from T1 to T4 Note The Expression suction speed is switched in following sequence T1 gt T2 gt T3 gt T4 gt T3 gt T2 gt T1 T1 fastest and T4 slowest 20 Pumping Instructions Continued 5 Adjust the suction to your comfort level by rolling the Vacuum Adjusting Wheel The current level is shown with the number marked on the Vacuum Adjusting Wheel The suction power gradually increases from 1 to 7 6 When your pumping session is finished
13. ith clean hot water Hang to AIR DRY COMPLETELY BEFORE USING Do NOT insert any object into the tubing Note Before each use visually inspect the individual components for cracks chips tears discoloration or deterioration as they may affect the efficiency of the Viverity Electric Breast Pump In the event that damage to the device is observed please discontinue use until the parts have been replaced 23 Breastmilk Storage Guidelines Check with your healthcare provider or an International Board Certified Lactation Consultant for specific storage instructions This information is based on current research and applies to mothers who have healthy full term babies who are storing their milk for home use Important Notes e STORAGE CONTAINERS The best option for storing human milk is glass or hard sided plastic containers with well fitting tops When you are freezing your breastmilk do not fill the container more than 3 4 full to allow for expansion from freezing Store milk in the main refrigerator or freezer compartment away from the door to avoid changes in temperature that may compromise the milk e RE WARMING THE FROZEN MILK Frozen milk can be thawed in the refrigerator overnight or under cool running water Gradually increase the temperature of the water to heat the milk to feeding temperature Be sure to use thawed milk within 24 hours Discard any leftovers e RE WARMING THE REFRIGERATED MILK Refrigerated milk can be warmed by
14. lly acceptable for the period of one year from the date of purchase on the pump mechanism and a period of 120 days on all other components Warranty coverage terminates if you sell or otherwise transfer this product to another person This warranty gives you specific legal rights and you may also have other rights which vary by location VIVERITY MAKES NO EXPRESS WARRANTY OF ANY KIND REGARDING THIS PRODUCT OTHER THAN THOSE WARRANTIES SET FORTH HEREIN ANY IMPLIED WARRANTY INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW SHALL BE LIMITED IN DURATION TOA PERIOD OF 120 DAYS FROM THE DATE OF PURCHASE BY THE ORIGINAL PURCHASER In the event that this product is found by Viverity to not meet the above limited warranty as purchaser s sole and exclusive remedy Viverity will repair or at the option of Viverity replace this product without charge for such replacement parts or labor The purchaser shall bear all expenses related to returning this product to Viverity This warranty does not apply to any part of the product that has been subject to misuse abuse or alteration Only Viverity brand replacement parts are recommended for use with Viverity breastfeeding products Improper or incorrectly performed maintenance or repair or use of non Viverity brand replacement parts voids this warranty TO THE EXTENT PERMITTED BY LAW VIVERITY SHALL NOT BE
15. ngle Collection Kit ROS SGKIT e Double Collection Kit ROS DBKIT e One Way Valve 4 pieces ROS 1VLVE Bottle Set Bottle Cap Sealing Disc and Bottle Ring Single Collection Kit Cap Diaphragm Cup with O Ring Breast Shield One Way Valve Bottle Adapter Collection Bottle and Bottle Base Double Collection Kit Cap Diaphragm Cup with O Ring Breast Shield One Way Valve Bottle Adapter Collection Bottle and Bottle Base One Way Valve Includes four 4 individual valves 29 Technical Data Power Requirements e AC DC Adapter included North American Plug configuration Model GDP 12AV 1201000 100V 240V AC 50 60 Hz 0 45A wall plug type AC DC Adapter with DC 12V 1A output e Batteries 4 AA Batteries 1 5V Alkaline Technical Specifications VACUUM T1 phase 177mmHg T2 phase 216mmHg T3 phase 240mmHg 32kpa T4 phase 250mmHg 33 4kpa Ambient temperature range 10 C to 40 C 50 F to 104 F Relative Humidity range 2096 to 8096 23 6kpa 28 9kpa NN Key to Box Symbol e Type BF equipment Breastshield e i Consult instructions for use e X Disposal of Electrical amp Electronic Equipment WEEE Made in China Manufactured by RumbleTuff 30 Limited Consumer Product Warranty United States This Viverity Tr Comfort Electric Breast Pump is warranted to the original consumer the purchaser to be free from defects in material and workmanship which are not commercia
16. nlet AC DC Adapter Inlet Parts Guide e Expression Collection Combo Kit Cap Electric pump Diaphragm Diaphragm Kit Cup with O Ring Silicone Cushion Breastshield Body Expression One Way Valve Collection Kit Bottle Adapter Collection Bottle Bottle Base How to Assemble the Expression Collection Kit Your Viverity Electric Breast Pump comes pre assembled however you will need to re assemble it after each cleaning For cleaning instructions see page 22 Below is a step by step guide for assembling the Expression Collection Kit 1 Hold the horn of the Breastshield Body in one hand Make sure the bottle thread side opening is facing up 2 With the thumb and forefinger of the other hand hold the tip of the One Way Valve and place the flat circular bottom into the opening Be sure not to stretch bend or twist the tip of the One Way Valve Seal all the edges firmly Note The One Way Valve tip does not have to align with anything as long as all the edges are securely sealed z i j Flat Circular Bottom Tip How to Assemble the Expression Collection Kit Continued 3 With your thumb and forefinger gently seal any openings on the tip of the One Way Valve and shape into a straight line Note This is critical to the performance of the pump L 4 Carefully twist on the Bottle Adapter to the Breastshield Body for a secure fit Note Be sure not to bump the One
17. nsure the tubing is free from any liquid Do NOT operate your Viverity Electric Breast Pump if any liquid is visible in the tubing See Tubing Cleaning Instructions on page 23 General Cleaning Instructions Caution Take care when cleaning the One Way Valve If it gets damaged your breast pump will not function properly To clean the One Way Valve rub it gently between your fingers in warm soapy water be P then rinse thoroughly in clean warm water Do not insert any objects into the One Way Valve as this may damage the valve e Set aside the tubing and tubing Connector Under the normal working conditions of the pump the diaphragm prevents the back flow of milk Therefore these items do not need to be washed In case of finding any liquid or liquid vapor inside the tubing follow the Tubing Cleaning Instructions on page 23 carefully before use e All parts of the Expression Collection Combo Kit may be cleaned in the upper compartment of your dishwasher or hand washed with dish soap in hot water 22 Cleaning Instructions Continued e Do NOT use solvents or abrasives e Rinse with hot clean water e To clean the Electric Pump Main Unit wipe it with a wet wipe or damp cloth using only water or water mixed with a mild soap Tubing Cleaning Instructions e Wipe the outside of the tubing with a clean damp cloth Avoid getting water or other fluids inside the tubing e f liquids are found inside tubing rinse the tubing w
18. on around the edges of the horn Note Your Electric Breast Pump will work with or without the Silicone Cushion Your comfort depends on your preference 4 Take the open end of Vacuum Tube the end without the adapter and connect to the Tubing Connector located on the Cap Push together firmly for a tight seal Note Make sure there is no moisture in the tubing To Use As a Single Pump Remove one tube and close the T connector Connector 5 Make sure the Tubing Connector is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit pu T 14 Power Options Your Electric Breast Pump may be operated under any of the following power supply modes Using your AC DC Adapter included e Electrical safety can only be achieved when using the AC DC Adapter which was provided with the pump Use of any another Adapters causes concern for the safety of the product and or the user and voids the warranty 1 Plug the AC DC Adapter into an electrical outlet 2 Attach the Power Cord to the AC DC Adapter Inlet on the Electric Pump Main Unit Using 4 AA Alkaline Batteries not included a 4 AA Batteries 7 not included AA Battery Compartment e Always replace all 4 AA Batteries at the same time e Remove all batteries from the Electric Pump Main Unit if the Pump is not going to be used for extended periods of time e Properly dispose of all batteries according to governm
19. ot drop or insert any object into any opening or tubing e Do not use outdoors with the AC DC Adapter or operate where aerosol spray products are being used or where oxygen is being administered Important Safeguards Continued e Make sure the voltage of the AC DC Adapter is compatible with the power source e Plug the AC DC Adapter into the electrical outlet first then plug the power cord into your Viverity Electric Breast Pump e Viverity has provided an AC DC Adapter with this device Using any other AC DC Adapter not approved by the manufacturer voids the warranty e f you are infected with Hepatitis A Hepatitis B or have HIV Human Immunodeficiency Virus pumping breast milk does not reduce or remove the risk of transmitting the virus to your baby through breast milk e Wash the Expression Collection Combo Kit parts before each use e Do not operate a motor vehicle while using the Viverity Electric Breast Pump e Do not attempt to modify the product SAVE THESE INSTRUCTIONS along with your receipt for future reference Vacuum Tubing with Adapter Breast Pump Main Unit Parts Guide Qe Spare Parts AC DC Adapter 2 Valve and 4 O Ring a Bottle Adapter Kit Set of 2 Expression Collection Combo Kit Parts Guide e Electrical Pump Main Unit TOP VIEW T1 T2 T3 T4 LED Screen Vacuum Adjusting Wheel Expression Button Power Button BOTTOM VIEW Battery Cover Tubing Adapter I
20. umping session will help your let down reflex start continue e Go to a non stressful environment e Use a comfortable chair that gives lower back support with or without a footstool After all you re the one who has to be comfortable Depending on your health and milk production condition you may be able to achieve more than one let down in one pumping session Most mothers have more than one let down while breast feeding and don t even notice the change To achieve multiple let downs which mimics the natural reflex found in breast feeding you can switch the suction speeds T1 fastest and T4 slowest just by pressing the Expression Button The suction speed is switched in the following sequence T1 gt T2 gt T3 gt T4 gt T3 gt T2 gt T1 Remember that successful pumping is a learned skill Don t get discouraged and keep working at it to obtain the best results Breastmilk is produced on a supply and demand basis expressing your breastmilk regularly stimulates and maintains your milk supply If it feels uncomfortable or painful on your breasts while using the pump try decreasing the suction level by rolling the Vacuum Adjusting Wheel down If these tips do not help turn the product off and remove the pump from your breasts for a few minutes If you are still experiencing pain or discomfort consult your healthcare professional or an international board certified lactation consultant 26 Tips Continued Breastfeeding
Download Pdf Manuals
Related Search
Related Contents
GE AMH12 Air Conditioner User Manual VX-7R Operating Manual Owner's manual - Allied Hand Dryer GFI MailEssentials Administrator Guide Dell PowerEdge R430 Manual del propietario Philips EcoClassic Candle deco lamp Halogen candle bulb 872790092506700 R.S.V.P. - vendaModa.com.br SE260 User Manual InLine 33056I audio converter Copyright © All rights reserved.
Failed to retrieve file