Home
USER`S GUIDE - Digital Loggers
Contents
1. Web Power Switch 7 USER S GUIDE 9 DIGITAL LOGGERS INC Product Features Congratulations on selecting the DLI Web Power Switch a surge suppressed AC power switch with automatic reboot and programmable power control Features include Simple Web Interface The internal web server is accessible from any standard browser Simply enter an IP address The controller may be configured and controlled via the web Auto Ping Reboot This automatic feature monitors a remote IP address If a server router or other peripheral goes down the switch will automatically reboot it without user intervention Up to 8 devices can be monitored individually 8 Switched Outlets 2 Unswitched Outlets Eight individually switched controlled circuits are provided with single outlets Outlets are spaced for large adapters and plugs Un switched outlets are provided for always on devices LCD Display A 2x16 LCD displays status for each outlet Custom messages can be displayed using a simple scripting language Password Security Multi user password security is provided to limit access to the power controller The administrator selects which outlets each user controls Sequenced On Timer A programmable delay timer allows outlets to be switched on in sequence rather than simultaneously Most devices draw more power when they are initially switched on Using this timer more Web Power Switch 7 digital loggers com equipment can b
2. each change click Submit and wait for the page to refresh before continuing gt Tips e Athree bulb electrical safety tester is handy for configuring the controller before attaching your equipment e Please register your product for better support and free firmware updates IP Setup If your network settings won t access the default IP use a direct cable connection temporarily bypass any switch or router and follow these steps to add a compatible static IP such as 192 168 0 50 Before adding an IP close programs and browsers After the link is established you can revert to DHCP if desired or use a combination of DHCP and static IPs Kd DIGITAL LOGGERS INC Web Power Switch 7 Windows Step 1 In Windows the first step is locating the network adapter TCP IP properties The procedure differs for each Windows version Windows XP 2000 2003 Open Start Control Panel Network Connections If you re using classic view it s Start Settings Control Panel Network Connections Right click on Local Area Network Connection and select Properties Proceed to step 2 Windows Vista Open Start right click on Network then on Properties Double click Network and Sharing Center click Manage Newtork Connections A Network Connections window appears Right click on the network connection to the switch ie Local Area Network Proceed to step 2 Windows 7 Open the Start orb click on Control Panel Use the default Catego
3. the outlet name or number Switching is immediate Individual Control Name State Action 1 DSL Router ON Switch OFF Cycle Use the keypad for local control Select an outlet using the arrow keys then press on off or cycle Press ON or OFF for 5 seconds to lock or unlock an outlet Locking prevents web access You may also Cycle a device which is connected to the controller This feature is useful for rebooting Ethernet devices which may interrupt the web link to the controller Clicking Cycle switches power off waits for the ON Delay time and then switches power back on This reboots the attached device Web Power Switch 7 digital loggers com You can also cycle all outlets using the Master Control on the bottom of the page An adjustable ON sequence delay takes effect when cycling when using All Outlets ON and on power up Master Control All Outlets GFF All Outlets ON Cycle all Outlets Sequence delay 3 Depending on your web browser settings you may need to click the Refresh button or F5 key to update the on screen status display after changing settings Screen refresh rate is adjusted in two places on the Setup page and in your browser settings Setup Page The Setup page allows the administrator to configure the power controller These settings are supported Controller and Outlet Names Use the controller name field to assign a Controller Name to the power controller itself Examples are Server Rack 4 PDU o
4. times a target device will be rebooted by entering a value here For example entering 5 will reboot your server up to 5 times before giving up and leaving it on Device Reboot Delay After power cycling to reboot a device a waiting period will occur before the IP address is re checked by Auto ping This delay allows the device time to reboot Most devices take some time to reboot Windows and Linux servers can force automatic file system checks which may take several minutes to complete To allow for startup delays enter a time delay in the Device Reboot Delay period For example a reasonable value for a typical server might be 10 minutes 600 seconds Entering 600 would cause the power controller to start checking the server for normal IP operation 10 minutes after reboot Find a detailed explanation at digital loggers com Autoping html Auto Ping Example In this example we use Auto Ping to automatically reboot a DSL router Since the switch is connected inside the router we select a target IP of 8 8 8 8 This is a multi cast address which connects to a multidude of Google name servers We can safely assume that if none of them respond we have lost network connectivity We connect the router to outlet 1 and add the external IP here leaving all timing values at defaults We first add the IP here eee r r IP Script Action 1 Ae ee ee ec ee es O08888 MOoOooododoodda i Add IP Address to AutoPing P Address Web Power
5. Switch 7 digital loggers com After clicking the green checkbox Auto Ping will check for several responses before enabling itself After that the router will be monitored and automatically rebooted Had we entered a number in the Script box a program would be excuted starting at that line number when the target router required reboot Find more examples at digital loggers com Autoping html Mobile Device Access The power controller will automatically zoom webpages to fit smaller mobile device screens To use this feature first log in as admin Then create a user such as mobile The webserver will auto detect the screen size of the mobile user This feature is not avilable when logged in as admin The larger admin pages require a full size screen Anumber of third party applications are available to control the switch from Android and loS Find more information here digital loggers com mobile html Real Time Clock The internal Real Time Clock RTC is provided This clock can be set manually using the Date Time link The time zone can be selected based on GMT To syncronize the clock to a networked time standard an NTP command is provided in the scripting language Internal batteries have an estimated 15 year lifetime Scripting Example The controller can be used as is in most applcations or customized using a BASIC scripting language A full description is beyond the scope of this manual so please visit our we
6. bsite for other examples and a full command list Here s a simple example a lighting economizer Kd DIGITAL LOGGERS INC Web Power Switch 7 This simple program shuts the lights off at 9 30PM daily Users can turn them on using a web browser Should they forget to turn them off the power switch takes care of it User strings 3 A EAk Ense Script listing 1 WATI ee D OFS ETRE 2 OFF 12345678 Find more scripting examples and a full list of commands at digital loggers com Scripting html Windows Logging and Email Notification A Windows utility can be used to record activity and notify you when specified trigger events occur This utility also logs power consumption and generates reports when used in conjunction with our larger power controllers Learn more and download the utility free at digital loggers com pcl html Web Power Switch 7 digital loggers com Specifications Alert Beeper 73dBa at 12 Programmable power control and reboot Indoor use only Circuit Breaker Manual reset 15A Thermal UL Clock RTC 15 year Li battery NTP support Control Display Reset to factory default switch 2x16 Backlit LCD w PowerSave Dimensions Outside 1 6x5 8x13 12 3 Between mtg holes EEPROM 512Kb I2C Standard Enclosure Aluminum chassis double grounded Injection olded high temp thermoplastic base plate Vented 2 sides Fanless 8 pin RJ 45 w internal FCC filtering FCC Testing Part 15 S D Humidi
7. ched to two different circuits Learn more digital loggers com auto ping html System Log The power controller keeps a log of system events including logins successful and attempted outlet switching power interruptions and Auto Ping events Recent events are stored in the log and accessible from the System Log page Multiple controllers can export logs to a single external SYSLOG server For more information on syslog digital loggers com syslog html Logout The controller will automatically log out when your browser session is closed Click this link to log out in advance K DIGITAL LOGGERS INC Web Power Switch 7 E Help The Help link displays the latest online manual Since features are subject to change without notice this manual may not be an exact match for earlier controllers and earlier firmware versions Find the firmware revision history here Programmable Web Links Four additional user defined web links are provided on the outlet control page Factory defaults are Manual FAQ etc You may change the name and destination URL for these links on the Settings page These links are convenient for connecting to other power controllers or to remote sites Switching Outlets On and Off The outlet control page lets you control any outlet except the always on pair A master setting also allows users with security access to switch all outlets on or off To switch an outlet on or off simply click to the right of
8. e attached to a single circuit without overloading Programmable scripts can also be used to create customized power up and power down sequences with variable timing MOV Surge Suppression A 3600W metal oxide varistor clamps power surges and spikes protecting all attached devices Scripting Language Syslog and Utilities A scripting language can be used to create custom control and reboot sequences schedule periodic reboots customize the LCD and control serial devices Both internal and external system logs are provided Windows utilities send status notifications warnings and power bills via email New Features New features include a larger keypad extended real time clock battery life scheduling function removable power cord Wake on Lan WOL support NTP sync Apple iOS and Android support Learn more about new features here Field Upgradeable Firmware Firmware is field upgradeable via Ethernet using the web or a command line utility Standard Package Contents e Web Power Switch 7 e Power Cord e Registration Card e Manual Please contact the shipping carrier immediately if your package appears opened or damaged in transit Call DLI at 408 330 5599 for tech support service and hardware upgrades K DIGITAL LOGGERS INC Web Power Switch 7 Important Factory Defaults DEFAULT IP ADDRESS The factory default is 192 168 0 100 DEFAULT ADMINISTRATOR LOGIN Username admin lower case Password 1234 j yo P
9. em for rebooting IP equipment without human intervention Auto Ping will monitor a device If it stops responding Auto Ping will cycle power to reboot it For example you might use Auto ping to monitor an external multi cast IP to automatically reboot a DSL router or WiFi AP To use Auto Ping first add an IP address Next link that IP address to one or more outlets Timing settings must be considered Add IP Address to Auto Ping Use this option to specify the address of an IP device you wish to monitor After entering the IP address the settings page will refresh and you can select the outlets associated with this address Use the checkboxes in the Auto Ping section to correlate the IP address to one or more outlets If communications to the target IP is lost these outlets will be rebooted Four parameters control Auto ping operation Time between pings This is the time between each ping check of the IP address 60 seconds should be useful for most applications Ping failures before reboot This sets the number of failed communications attempts that must be sequentially detected before a power cycle For example when set to 5 the target system must fail to respond 5 times in a row before it is rebooted Since occasional network Kd DIGITAL LOGGERS INC Web Power Switch 7 timeouts and packet loss can occur during normal Ethernet operation between 5 and 10 pings is suggested Times to Attempt Reboot Limit the number of
10. hen log in User admin has access to all features Other users have limited access to outlets as assigned by the administrator When configuring the power controller for the first time use the default admin username and 1234 password The home page contains 13 external hyperlinks The first nine are fixed internal links The four links in the lower left corner of the screen are user programmable EJ Web Power Switch 7 digital loggers com Outlet Control Clicking Outlet Control links to the home page used for manually switching outlets on and off Access to specific outlets is determined by your login User admin has access to everything Setup The setup page lets you select outlet names program web links startup delays and the power loss recovery mode You can also change login credentials on this page Scripting A scripting language using BASIC commands lets you customize the power controller Scripts may be started manually automatically on power up by external http commands or by Auto Ping events Find a full list of commands and example scripts at digital loggers com scripting html Auto Ping The Auto Ping link lets you set parameters for automatically reboot attached equipment First specify an IP address to ping Next adjust the timing settings and use the checkboxes to link the IP to specific circuits For example if a router is unreachable you may choose to automatically reboot both a router and a switch atta
11. ication Buyer acknowledges and agrees that it is solely responsible for proper use certification and safety testing of components supplied by DLI DLs entire liability and exclusive remedy as to defective hardware shall be at DLI s option either a return of the purchase price or b replacement or repair of the hardware that does not meet DLI s quality control standards and has been returned through proper RMA procedures DLI s liability for repair or replacement is to DLI s customer ONLY WARRANTY SERVICE DOES NOT INCLUDE SOFTWARE OR HARDWARE UPGRADES No warranty service will be provided without an original invoice from DLI and an RMA number provided by technical support RMA material must be shipped prepaid to DLI RMA numbers are valid for 15 days from date of issue This warranty does not cover products modified subjected to rough handling or used in applications for which they were not originally intended Batteries are not covered under warranty Physical damage caused by customer or in transit to DLI is not covered under warranty No oral advice or verbal warranties made by DLI s employees dealers or distributors shall in any way increase the scope of this warranty DLI makes no warranty as to merchantability or fitness for any particular purpose DLI assumes no liability for incidental or consequential damages arising from the use or inability to use this product This warranty gives you specific legal rights You may also have
12. m mac_ip_setup pdf Basic Operation After power up the controller performs a sequence of self tests to ensure reliability Network settings on the Settings page are used Network MAC Address HTTF port IP address Subnet mask Kd DIGITAL LOGGERS INC Web Power Switch 7 The IP address of the controller needs to match the class C of your system In other words the first three bytes 192 168 0 must be the same as the IP address on your computer in order to access the controller Using a Ping utility is a good way to confirm you have a valid network configuration A gateway setting is Once you have a connection the controller may be operated via a web browser To access the controller enter the IP address in the URL field of your web browser The default is http 192 168 0 100 Home Outlet Control Page Controller WISP Tower 1 Ethernet DIGITAL Power Mon Apr T IT3232 2013 DLI LOGGERS INC Controller Individual Control Outlet Control Name State Action Setup Set Device Names Here ON Switch OFF Cycle Scripting VYiathe SETUP Page OFF Siwitch ON Date Time 3 Cisco Router 3825 OFF Switch ON AutoPing 4 DSL Router ON Switch OFF Cycle system Log o Solar Charge Controller ON Siwitch OFF Cycle Logout 6 WiFi AP South ON Switch OFF Cycle support T Cooling Fans ON Siwitch OFF Cycle Help 6 Backup Router ON Siwitch OFF Cycle To access the home page first enter the IP address in web browser URL field t
13. other rights that vary from state to state Since some states do not allow the exclusion of liability for consequential damages some of the above limitations may not apply to you Auto Ping is a registered trademark of Computer Performance Inc Since this is a FLASH based product firmware should not be updated over the Internet or a busy LAN Packet loss could result in FLASH corruption requiring mail in service This product is designed for indoor use only It is not intended for and should not be used in outdoor mobile airborne or FDA Class III applications DIGITAL LOGGERS INC 2695 Walsh Avenue Santa Clara CA 95051 FAX 408 541 8459 digital loggers com SUPPORT DIGITAL LOGGERS COM 2013 DLI This product is protected by pending US patents and foreign patents Release 1 6 D 4 15 2013 Web Power Switch 7 digital loggers com Related Products Web Enabled DIN Relay 48V Smart Switch Smart PoE Injector Call 408 330 5599 x DIGITAL LOGGERS INC Web Power Switch 7 Auto ping Function Online Manual Scheduling Function Product Suggestions BASIC Scripting DIGITAL LOGGERS INC 2695 Walsh Avenue Santa Clara CA 95051 Tel 408 330 5599 Fax 408 541 8459 digital loggers com
14. ower Controller x C D 192 165 0 100 User Name Fassword 1234 To reset the IP address and admin login to factory defaults gently press the reset to defaults button to the left of the LCD Note Reset to defaults sets the admin login and IP address but it doesn t affect outlet names links and stored scripts Auto Ping and auto start of custom scripts are disabled Quick Setup Use these shortcuts if you are an experienced installer If this is your first time please skim the entire manual first 1 Remove the switch from its shipping carton Save the carton and packing for future hardware upgrade 2 Attach the power cord to a protected power source with a capacity of at least 15 amperes 3 Attach the cable from the controller to a port on your Web Power Switch 7 digital loggers com LAN Switch power on If you are connected to a switch you may need to cycle power to the switch to establish a connection 4 Ping the default address 192 168 0 100 to confirm a network connection is established If you don t receive a response see the IP Setup section below 5 Log in to the power controller using the default user name admin and the password 1234 admin must be entered in lower case Click on the Settings link to reach the configuration page 7 Select the safest power loss configuration for your installation all OFF all ON or pre powerloss 8 Configure the power switch as described below After
15. r Phone Room Power Switch The Controller Name appears on top of all pages Assign a separate name to each outlet such as DSL Router 1 or Backup Email Server to aid identification Check the Confirm check box to the right of the outlet name if you would like a pop up window to appear before switching critical outlets Power On Sequence Delay The power controller will pause for a period specified in the All ON Sequence Delay before switching each outlet on This delay helps prevent power surges and blown circuit breakers which can occur when multiple devices are switched on simultaneously A delay of 60 seconds is suggested for server applications This delay value is also used in the Cycle function You may also enter a screen refresh delay in this section If Enable screen refresh is checked and a delay value is entered your browser should periodically update the status screen Wrong Password Lockout Kd DIGITAL LOGGERS INC Web Power Switch 7 After three failed login attempts the switch can disable access for a selected period of time 0 60 Minutes Power Loss Recovery Modes The power loss recovery mode setting has three settings which take effect after a power failure When recovering O Turn all Outlets off after power loss O Turn all Outlets on in delayed sequence Return to pre powerloss state 1 You can turn all outlets off all systems will be switched off until manually turned on later 2 You can automatically t
16. ry View Click View Network Status and Tasks then Change Adapter Settings Proceed to step 2 Windows 8 Mouse or swipe to the bottom right corner Select Settings Select Control Panel Use Category View Select Network and Sharing Center Change Adapter Settings Right click on the connected network and select Properties Go to step 2 Windows Step 2 The second step is adding an IP such as 192 168 0 50 If you are using DHCP it s easiest to temporarily disable it while configuring the switch Select Internet Protocall TCP IP V4 Properties and Obtain an IP address automatically click Properties IP address 132 168 0 50 Enter a compatible su ask 255 255 255 0 static IP such Default gateway 192 168 0 1 as this Fal Web Power Switch 7 www digital loggers com Click Apply and close windows Ping the power switch to confirm the connection Point your browser at 192 168 0 100 and log in Find detailed instructions at digital loggers com ip_setup html Max OS X Turn AirPort off temporarily Click the Apple logo then System Preferences then Network Select Built In Ethernet and then Configure Under the TCP IP tab select Manually and enter an IP address sucha s 192 168 0 50 as shown gt AirPort Configure IPv4 Manually IPv4 Address 1927 168 0 50 Subnet Mask 255 255 0 0 Make changes shown Point your browser at 192 168 0 100 and log in Find detailed instructions at digital loggers co
17. ty 8 80 RH Operating Input Power Cord Removable C19 14AWG 6 length standard Inlet and Outlet Rating UL CSA 15A 120VAC only Input Frequency Power supply DC 400Hz Operating Temperature 30 to 170 F 34 to 77 C Options User e Right Angle 19 rack mount bracket Power Supply Rating 90 240V AC DC Autosensing Password Transmission Encrypted base 64 Movable HTTP port for security Power Dissipation 3 9W Typ Max all on lt 3 W idle Power Fail Hold Over 350ms minimum all relays on Power Up Modes Last used settings all power on or off sequential on or run BASIC program script Relay Contact Spec 15 25A AC DC 1 2HP Software Controls Individual outlets on off all on off cycle Net settings Web UI Surge Protection 3600W Metal Oxide Varistor Size Single Pack Carton 2 4x7 7x15 8 Weight bare Single unit 3 6 lbs excl cord amp packaging e DIGITAL LOGGERS INC Web Power Switch 7 IE Limited Five Year Warranty The terms of this warranty may be legally binding If you do not agree to the terms listed below return the product immediately in original unopened condition for a full refund The purchaser assumes the entire risk as to the results and performance of the unit DLI warrants this power controller to be free from major defects No agency country or local certifications are included with this unit It is the responsibility of the user to obtain such certifications if necessary for the customer s appl
18. urn all outlets on using the All ON sequence delay timer described above 3 You can return to the same outlet settings that were used prior to the power loss ie 1 On 2 Off etc The ON Sequency delay timer is used Note If you have written a script and enabled scripting the script will start automatically on power up at LINE 1 User Defined Links You may link to other power controllers your own web pages or remote web sites by entering up to four URLs and descriptions in the Setup page For example enter Site Two Power Controller in the description field with a URL of 192 168 0 250 These links appear on the home page Access Control The administrator can restrict user permissions to certain outlets To set permissions login as admin then create a permissions matrix by entering user names on the left and checking permitted outlets to the right of each user name Network Settings A valid fixed IP address network mask and gateway must be entered in this section Web Power Switch 7 digital loggers com When changing IPs you may need to restart your network switch to validate the new IP on an auto configuring switch port Be sure to record the new IP address Use the Protect button to lock the network settings Once protected the network settings cannot be changed except by pressing the physical reset button below the LCD Auto Ping Auto Ping Operation and Settings Auto Ping is an automatic syst
Download Pdf Manuals
Related Search
Related Contents
Origin Storage 3TB SATA 7.2K 3.5" mundocontrol Electrolux 55 GLXA User's Manual transportables high-power-verstärkersystem txa-900cd specifications - Webstaurant Store Olympus Stylus 1040 Instruction Manual USER`S MANUAL Halsey Taylor Owners Manual Manual del Propietario – Halsey Keysight 53220A/53230A Universeller 350-MHz Copyright © All rights reserved.