Home
EB6F User Manual - Catering Equipment Supplier
Contents
1. Lincat User and Installation Instructions Electric Auto Fill Water Boilers EB3F EB4F EB6F EB6TF Please make a note of your product details for future use Date Purchased Model Number Serial Number Dealer IS339 ECN3539 Dear Customer Thank you for purchasing this Lincat product With correct use and careful maintenance as described in these instructions your Lincat product will give years of trouble free use y We produce over 450 different items of catering equipment and our range is constantly being extended and improved Find out more about Lincat products from your local distributor or direct from us CONTENTS CONTENTS aneneen A e ae eea a enta Aa a Aaea 2 SAFETY INFORMATION issscccc oes tensvecdinenteieneasntns a a aa 3 DELIVERY CHECKUIS T 2sesat career oiean aN A T A 3 TECHNICAL SPECIFICATIONS iscrns cpcsuce cusel te Gisela te Sofa ee le the 4 ACCESSORIES ease a aaa ei de ae a A ea eh 4 INSTALLATION acs ca ees seca cease eases cen E ae aie 4 CIE AINIIN Gia ascetic E E E T ianapdande 8 AN NANN O as EN Aa Nada sae tera ON hed 9 DIAGNOSTIC MESSAGE Sinnani el ed eee se ede comes 11 SERVICE INFORMATION kratcumiin nenon aaa EE baeiecdeagias 11 GUARANTEE aeaa eE e a EER RA uae aAa E L a AAE ARETA 12 IS339 ECN3539 2 AN SAFETY INFORMATION To prevent injury to yourself or your staff and to avoid damaging the product please read and follo
2. the power button until the software version is displayed Press Fn and the temperature will be displayed 3 Press the power button to cycle through the values 70 to 96 deg C Press the Fn button to select the required value The backlight adjustment screen is displayed next 5 Press the power button to cycle through the values 1 to 25 Press the Fn button to select the required value 6 The contrast adjustment screen is displayed next IS339 ECN3539 7 7 Press the power button to cycle through the values 35 to 60 Press the Fn button to select the required value 8 Press the power button to exit Standby If the boiler is to be left unused for a long period the element can be turned off by pressing the power button Filter replacement The FILTER display shows the estimated remaining life in the current filter cartridge When the filter needs replacing a reminder message is displayed This is followed by the change filter screen FILTER CHANGE S FILTER STANDBY CLEAR READ The boiler can be used without a and water taste may be affected Replace the filter as follows filter but scale may build up more quickly 1 Twist the base of the filter 90 degrees to the left and carefully lower the filter cartridge out of the unit It will contain a small amount of water Remove the black cap and place on the new filter Insert the filter fully into its recess and twist to the right to lock in p
3. ces may become hot For safety regulations the plug or means of disconnection must always be accessible Connecting to the electricity and water and waste supplies The boiler must be earthed Check that the voltage of your electricity supply corresponds to the voltage shown on the serial plate EB3F The boiler is supplied with a 13 amp plug If replacing the plug connect the terminals as follows e Green and yellow wire Earth E e Blue wire Neutral N e Brown wire Live L For safety regulations the plug or means of disconnection must always be accessible IS339 ECN3539 EB4F The boiler is supplied with a bulkhead cable connector and must be fitted with 2 5mm 3 core cable The supply end of the cable must be fitted with an all pole disconnection isolator switch with a minimum of 3mm contact separation For safety regulations the means of disconnection must always be accessible EB6F EB6TF The boiler is supplied with a bulkhead cable connector and must be fitted with 4mm single or 3 phase cable The supply end of the cable must be fitted with an easily accessible all pole disconnection isolator switch with a minimum of 3mm contact separation For safety regulations the means of disconnection must always be accessible Water supply and waste connection all models Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the mains water supp
4. e Fn button and turn the boiler off and on again at the mains supply If the fault persists call service for advice Message Displayed Possible cause Corrective action FILTER DESCALE Scale on level sensors e Descale Boiler overfilling e Check water inlet CAUTION valve SEE MANUAL STAMOBY CLEAR FILTER HO WATER Water turned off e Check water Inlet hose bent or blocked are and drain FAULT Water pressure too high i ce if faul SEE MAHUAL or low e Call service if fault Drain valve open ee STAMOBY CLEAR Boil dry overheat e Check FILTER HOT HEAT IHG protector tripped connections Temperature sensor fault e Call service if fault FAULT Element failed persists SEE MANUAL PCB fault STAHDEY CLEAR Faulty loose connection Temperature set too high e Reduce F TEER OWER TEMP Temperature sensor fault era za setting and try FAULT Boiler net filling again Excessive scale in tank poi SEE MANUAL e Call service if fault PCB fault persists STAMOBY CLEAR FILTER THERMISTOR Temperature sensor fault e Call service FAULT SEE MANUAL STAMOBY IS339 ECN3539 SERVICE INFORMATION For help with the installation maintenance and use of your Lincat equipment please contact our service department T UK 01522 875520 All service work other than routine cleaning should be carried out by one of our authorised service agents We cannot accept respo
5. lace Press and hold the Fn button for 5 seconds to reset the filter life monitor 5 Drain off approximately 5 litres of water to remove any loose carbon particles from the filter IS339 ECN3539 CLEANING Clean the external surfaces of the unit regularly to maintain hygiene Empty the drip tray regularly Wipe the dispensing tap daily to remove any limescale deposits and check that the water outlet is clear Wipe the unit down with a damp soft cloth Do not allow excess water to run into the unit Do not use abrasive creams or scourers MAINTENANCE Drip Tray Slide tray out to remove and empty Filter Twist to the left and remove See section on filter replacement Descaling The descaling procedure must be performed by trained personnel as it requires the removal of panels from the boiler and access to live electrical components The boiler should be descaled regularly to maintain efficient operation and water quality The frequency depends on the hardness of the local water and timely replacement of the filter The boiler is best descaled at the end of the working day to allow the descaling agent several hours to work Lincat recommends its own descaling agent available from Lincat spares department part code MS19 Wear protective clothing Isolate the boiler from the electricity supply Turn off the power and let the water cool to approximately 60 C to avoid injury Using a 3mm Allen key remove
6. ly via an accessible isolating tap with a 34 BSP thread The drip tray has a large capacity but if required it can be connected to a waste water outlet using a 2 bulkhead connector not supplied If cables are required to exit at either side of the boiler the thinner section between the moulded feet may be cut away using a junior hacksaw IS339 ECN3539 5 Control panel Water dispensing tap Filter cartridge Drip tray and cover ar OO N gt Serial plate IS339 ECN3539 OPERATION First use 1 Switch on the mains water supply and the electricity supply Leave the boiler for 30 minutes to allow it to fill completely Drain off approximately 5 litres of water to remove any loose carbon particles from the filter Regular operation The boiler starts automatically when the mains water supply is turned on After a short delay it fills with water and heats up During the heating cycle small quantities of water are added to ensure that hot water is always available at the tap The water temperature screen backlight and screen contrast can be adjusted as required The boiler is designed to be left permanently switched on it is only necessary to turn it off for descaling or maintenance Changing water temperature screen backlight and contrast 1 Turn power off and on again The Filter Flow screen is displayed LAKE Power Standby button Fn Function button 2 _ Press and hold
7. nsibility for work carried out by other persons To ensure your service enquiry is handled as efficiently as possible please tell us Brief details of the problem Product code Type number From serial plate beside dispensing tap Serial number Lincat reserve the right to carry out any work under warranty during normal working hours Monday to Friday 08 30 am to 17 00 pm GUARANTEE This unit carries a comprehensive UK twelve month warranty The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the instructions in these instructions Consumable items Damage due to incorrect installation modification unauthorised service work or damage due to scale The manufacturer disclaims any liability for incidental or consequential damages IS339 ECN3539 12 IS339 ECN3539 This page intentionally left blank
8. the screw on the top of the boiler Remove the insulation on top of the tank then unscrew and remove the tank lid 6 Add the descaling agent a little at a time as some types can cause hot water to erupt Always follow the manufacturer s instructions 7 Replace the tank lid and outer lid and attach an Out of Use notice to the boiler to prevent use during descaling 8 Turnon the electricity and allow the boiler to heat and run normally for approximately 30 minutes 9 Isolate the boiler and allow the water to cool IS339 ECN3539 11 12 13 Remove the outer and tank lids again and inspect the tank and level sensor housings for scale deposits If necessary repeat the descaling process Drain and flush all descaling agent from the tank completely as follows i Remove the two screws behind the drip tray that secure the lower front panel ji Connect a hose from the overflow pipe to a bucket and turn the service valve to drain the remainder of the water from the tank iii Flush out the tank with clean water iv When empty shut the valve and replace the cover Replace the tank lid ensuring that the gasket is sealing the top of the tank correctly Fit the outer lid and turn on the boiler IS339 ECN3539 DIAGNOSTIC MESSAGES The control panel displays messages and information that can help with fault diagnosis Before calling for service draw off a litre of water clear the fault code by pressing th
9. w the safety precautions below before setting up and using the unit Remove all plastic coatings and clean the unit before use Ensure that the electrical supply cable is not damaged If it is it must be replaced by Lincat Ltd or by qualified personnel Always disconnect the unit from the electricity supply before servicing The unit must be earthed Do not try to modify this unit Never clean the unit with a water jet or steam cleaner Inform staff that the surfaces will become hot Keep these instructions in a safe place near the unit for future reference DELIVERY CHECKLIST If an item is missing please contact your dealer immediately Electric water boiler Drip tray and insert White water inlet hose with 3 4 BSP connection User instructions Guarantee card Filterflow badge Sample of descaling agent IS339 ECN3539 TECHNICAL SPECIFICATION Model EB3F EB4F EB6F EB6TF Width mm 290 290 455 455 Depth mm 465 465 465 465 Height mm 655 655 655 655 Power Rating kW 3 0 4 5 6 0 6 0 Net weight net kg 13 13 17 17 Ambient temperature C 5 to 30 Water inlet pressure Bar 1to 8 ACCESSORIES Wall mounting kit for EB3F EB4F BR49 Wall mounting kit for EB6F EB6TF BR50 Replacement filter cartridge FC02 INSTALLATION The boiler must be installed on a horizontal surface in a location where it can be supervised by trained personnel Inform all users that the surfa
Download Pdf Manuals