Home

E1330A/E1330B Quad 8-Bit Digital Input/Output Modules

image

Contents

1. 3 1 Replaceable Parts List goe awe ES v Gees RC S ai 3 1 Mechanical Parts Locator 3 5 Chapter 4 Service Introduction 4 varied te SR RR unu BE ee tenute 4 1 Equipment 4 1 Service Aids Bat RO PER ERE qn d 4 1 Digital I O Module Description 4 1 Strate sy 4 5 ste sl th pie ha is Bod eye Sa dian 4 2 Troubleshooting Techniques 4 2 Identifying the Problem 4 2 Making Visual 4 2 Testing the Module 4 3 Repair and Maintenance 4 4 ESD Precautions zv hoy ae i SOEUR c EU ie Re RU ee 4 4 Soldering Printed Circuit Boards 4 4 Post Repair Safety 4 4 Appendix A Verification Tests C Programs Funcitonal Verification Test via ee ee ee A 1 Performance Verification A 2 1 General Information I n t rod u cti on This manual contains information required to test troubleshoot and repair the Agilent E1330A B Quad 8 Bit Digital I O Module See the Agilent E1330A B User s Manual for additional information on the Agilent E
2. 1 4 Digital I O Module Environment 1 4 Digital I O Module Serial Numbers 1 5 Digital I O Module Options 1 5 Recommended Test Equipment 1 6 Inspection Shipping 22 22 2 4 1 6 Initial Inspection SR EO de So So a 1 6 Shipping Guidelin s ee 1 8 Chapter 2 Verification Tests Introduction 2 1 Test Conditions Procedures 2 1 Performance Test Record 2 1 Verification Test Examples 2 1 Functional Verification 2 2 Procedure Lorum DIM qid ee e eoe Nb 2 2 Operation Verification Test 2 2 Performance Verification Tests 2 3 Test Cable ai pees et ee Ee ded 2 3 Test 2 T Digital Test umb y eub Se aro ie Us ates 2 3 Performance Test Record 2 8 Test amp 8A Ag BEA EES m aeu qus 2 8 Measurement Uncertainty 2 8 Test Accuracy Ratio TAR ir grin RR ee 2 8 Chapter 3 Replaceable Parts Intfoduction 4 Sh de PSS us igh EAS
3. Digital I O Module Description This chapter contains service information for the Agilent E1330A B Quad 8 Bit Digital I O Modules Also included are trouble shooting repair and maintenance guidelines Do not perform any of the service procedures shown unless you are a qualified service trained technician and have read the WARNINGS and CAUTIONS in Chapter 1 Equipment required for module troubleshooting and repair is listed in Table 1 1 Recommended Test Equipment Any equipment that satisfies the requirements given in the table may be substituted To avoid damage to the screw head slots use a T8 Torx driver to remove the front panel handles See Chapter 3 Replaceable Parts for descriptions and locations of Agilent E1330A B replaceable parts Service notes manual updates and service literature for the modules may be available through Agilent Technologies For information contact your nearest Agilent Technologies Sales and Service Office The Agilent E1330A B provides four independent 8 bit digital I O ports compatible with TTL logic levels Each port can be software configured for operation as either input or output with either positive or negative true logic The ports can be combined to provide 16 bit WORD or 32 bit LWORD operations In addition to the eight digital data lines six handshake lines are included per port The handshake lines can also be combined via jumpers on the component assembly to provide proper hand
4. 1330 002121 0515 2140 0515 1968 0515 2743 76 229685 T These parts are not compatible with older version fixed handles or their corresponding front panels To replace or more of these old parts you must order all three new parts Top and Bottom Handle Kits AND Front Panel NOTE If the 4 IC s placed in the sockets are square in shape rather than rectangular the PC assembly 1 reference designator is the most recent Agilent E1330B release as listed above If the 4 IC s are rectangular see Figure 3 1 the PC assembly is an earlier E1330B release and must be replaced with a new Replacement Assembly Part Number E1330 66202 Replaceable Parts 3 3 Table 3 3 Agilent E1330A B Reference Designators Agilent E1330A B Reference Designators Table 3 4 Agilent E1330A B Code List of Manufacturers Manufacturer s Manufacturer s Name Address AMP Inc Harrisburg Dupont E De Nemours amp CO Wilmington Berg Electronics Inc Ettersill Molex Inc Lisle Agilent Technologies Corporate Palo Alto Littelfuse Inc Des Plaines 3M CO St Paul Grayhill Inc La Grange 3 4 Replaceable Parts Mec ha n ical Figure 3 1 shows the location of selected mechanical parts for the Agilent Pa 15 E1330A B Quad 8 Bit Digital I O Module Locator Figure 3 1 Mechanical Parts Replaceable Parts 3 5 3 6 Replaceable Parts 4 Service Introduction WARNING Eduipment Required Service Aids
5. 350 360 370 380 390 400 410 420 430 440 450 460 470 480 OUTPUT QDio SOUR DIG DATA amp VAL J amp IF J 2 THEN OUTPUT Dio MEAS DIG DATA amp VAL J 2 amp 2 ELSE OUTPUT QDio MEAS DIG DATA amp VAL J 2 amp END IF ENTER Dio A Number VAL A B DVAL Number 2 IF B 25 32 lt gt Bit_walk l THEN Fail 1 PRINT Failure of bit walk PRINT WRITE at port J IF J lt 2 THEN PRINT READ at port J 2 ELSE PRINT READ at port J 2 END IF END IF NEXT J NEXT I 2 6 Verification Tests 490 PRINT End of bit walk test 500 PRINT 510 PRINT Handshake line test 520 FOR T 1 TO 0 STEP 1 530 FOR I 20 540 OUTPUT QDio SOUR DIG CONT amp VAL I amp amp VALS T 550 IF 2 THEN 560 OUTPUT QDio MEAS DIG FLAG amp VAL I4 2 amp 570 ELSE 580 OUTPUT QDio MEAS DIG FLAG amp VAL I 2 amp 590 END IF 600 ENTER DIO A 610 IF VAL A lt gt T THEN 620 Fail 1 630 PRINT Failure of handshake lines 640 IF 1 lt 2 THEN 650 PRINT CTL line on port l to FLG line on l 2 660 ELSE 670 PRINT CTL line on port l to FLG line on port l 2 680 END IF 690 END IF 700 NEXT I 710 NEXTT 720 PRINT End of handshake line test 730 PRINT 740 0 THEN 750 PRINT Digital PASSED all tests 760 ELSE 770 PRINT Digital I O failed tests 780 ENDIF 790 END Typical Result Bit walk test of all ports for read and write no handshake En
6. TAR Test 2 1 Digital Test Read Write Test Port 0 Write Port 2 Read Port 1 Write Port 3 Read Port 2 Write Port 0 Read Port 3 Write Port 1 Read Handshake Test Port 0 CTL Port 2 FLG Port 1 CTL Port 3 FLG Port 2 CTL Port 0 FLG Port 3 CTL Port 1 FLG 2 10 Verification Tests 3 Replaceable Parts I ntrod u cti on This chapter contains information to order replaceable parts for the Agilent E1330A Quad 8 Bit Digital I O Modules with serial number prefixes 2934A and Agilent E1330B with serial number prefixes 3221A Table 3 1 lists replaceable parts for the Agilent E1330A Module and Table 3 2 lists replaceable parts for the Agilent E1330B Module Table 3 3 shows reference designators for parts in Tables 3 1 and 3 2 Table 3 4 shows the manufacturer code list for these parts To order a part listed in Table 3 1 or 3 2 specify the Agilent Technologies part number and the quantity required Send the order to your nearest Agilent Technologies Sales and Support Office Rep laceab le Table 3 1 lists mechanical replaceable parts for the Agilent E1330A Quad arts Li st 8 Bit Digital I O Module with serial number prefix 2934A Table 3 2 lists mechanical replaceable parts for the Agilent E1330B Quad 8 Bit Digital I O Module with serial number prefix 3221 A See Figure 3 1 for locations of mechanical parts Replaceable Parts 3 1 Reference Designator 1 CBL1
7. CBL2 CBL3 MP1 MP2 F1 J1 J2 J12 J15 J16 J51 J54 P1 P15 P51 P57 PNL1 SCR1 SCR2 SCR3 SCR4 SCR5 SCR6 swt Agilent Part Number E1330 66201 E1330 66501 E1330 61603 E1330 61601 1300 451011 1300 451021 2110 0712 1252 1044 1251 6515 1251 4927 1251 4682 1252 1596 1258 0247 1258 0141 1330 002121 0515 2140 0515 1968 0515 2743 3101 3066 Table 3 1 Agilent E1330A Replaceable Parts Part Description ASSEMBLIES and CABLES See Figure 3 1 REPLACEMENT ASSEMBLY PC Assembly Digital I O 32 Channel Test Cable issued with Service Kit Ribbon Cable not illustrated HNDL KIT TOP Agilentt HNDL KIT BTM VXIT Fuse subminiature 4A 125V NTD AX Connector post type 100 pin spcg 60 contact Connector post type 100 pin spcg 6 contact Connector post type 100 pin spcg 16 contact Connector post type 100 pin spcg 3 contact Connector post type 2 54 pin spcg 96 contact Four position Jumper Removable Jumper PNL RR 4 CH DACT SCR THD RLG 2 5 X0 45 14mm Screw M2 5 X 0 45 11mm long pan head SCR FH M2 5 X 8 THREAD ROLLING Switch dip Rocker 8 1A 0 15A 30 VDC Mfr Part Number E1330 66201 E1330 66501 E1330 61603 E1330 61601 1300 451011 1300 451021 R251004T1 3372 5302 67996 606 2416 6182TB 22 10 2031 536010 5 69146 204 530153 2 1330 002121 0515 2140 0515 1968 0515 2743 76 229685 T These parts are not compatible with older version fixed handles or their corresponding fr
8. Documentation have been developed entirely at private expense They are delivered and licensed as commercial computer software as defined in DFARS 252 227 7013 Oct 1988 DFARS 252 211 7015 May 1991 or DFARS 252 227 7014 Jun 1995 as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 Jun 1987 or any equivalent agency regulation or contract clause whichever is applicable You have only those rights provided for such Software and Documentation by the applicable FAR or DFARS clause or the Agilent standard software agreement for the product involved Agilent E1330A E1330B Quad 8 Bit Digital Input Output Modules Service Manual Edition 3 Rev O Copyright 1996 2006 Agilent Technologies Inc All Rights Reserved Printing History The Printing History shown below lists all Editions and Updates of this manual and the printing date s The first printing of the manual is Edition 1 The Edition number increments by 1 whenever the manual is revised Updates which are issued between Editions contain replacement pages to correct the current Edition of the manual Updates are numbered sequentially starting with Update 1 When a new Edition is created it contains all the Update information for the previous Edition Each new Edition or Update also includes a revised copy of this printing history page Many product updates or revisions do not require manual changes and conversely manual
9. X module s ability to set and reset the handshake lines on each port Digital I O Test E1330A include lt stdio h gt include lt stdlib h gt include lt sicl h gt define ADDR hpib7 9 18 Address of device void main void INST id Define id as an instrument char a 255 b 32 char bit walk 00000001 00000010 000001 00 00001000 00010000 00100000 01000000 10000000 int bit val 1 2 4 8 16 32 64 128 int fail i j number int atoi const char a if defined __BORLANDC amp amp defined WIN32 _InitEasyWin endif ionerror ERROR EXIT id iopen ADDR Open instrument session iprintf id CLS n fail 0 printf nInstall component assembly and test cable printf n n 1 Turn mainframe power off printf n 2 Install E1330A B component assemby into mainframe printf n 3 Attach test cable to component assembly printf n 4 Turn mainframe power on printf n 5 Press ENTER when ready to begin testing gets a A 2 Example C Programs printf n nBit walk test of all ports for read and write handshake for i O i lt 7 i p j 0 j lt 3 j iprintf id SOUR DIG DATA u B s n j bit walk i D d MEAS DIG DATA u n j 2 yet id MEAS DIG DATA u n j 2 iscanf id t a number atoi a if number bit val i fail 1 printf nFailure
10. number For Port 1 CTL use Port 3 FLG For Port 2 CTL use Port O FLG For Port 3 CTL use Port 1 FLG 6 Reset the module jumpers Turn mainframe power OFF Remove the Test Cable from the module Remove the module from the mainframe Reset the module jumpers to the positions recorded in Step 1 This example performs a bit walk test of all bits on all ports and checks the module s ability to set and reset the handshake lines on each port 10 20 30 40 50 60 RE SAVE DIO TEST DISP CHR 129 ASSIGN Dio TO 70918 OUTPUT Dio CLS Fail 0 DIM A 255 B 32 Bit walk 7 8 70 00000001 00000010 00000100 00001000 00010000 00100000 01000000 10000000 Verification Tests 2 5 80 READ Bit walk 90 CLEAR SCREEN 100 PRINT Install Component Assembly and Test Cable 110 PRINT 120 PRINT 1 Turn mainframe power OFF 130 PRINT 2 Install Agilent E1330A B component assembly into mainframe 140 PRINT 3 Attach test cable to component assembly 150 PRINT 4 Turn mainframe power ON 160 PRINT 5 Press Continue when ready to begin testing 170 PAUSE 180 CLEAR SCREEN 190 OUTPUT QDio IDN 200 ENTER Dio A 210 IF A 17 21 lt gt E1330 THEN 220 PRINT Incorrect Card Type detected 230 STOP 240 END IF 250 PRINT Bit walk test of all ports for read and write no handshake 260 FOR l 0 TO7 270 FOR J 0 TO 280 B amp Bit_walk 1 290 300 310 320 330 340
11. sent Repeat this step using the following binary data strings 00000010 00000100 00001000 00010000 00100000 01000000 and 10000000 Use the command SOUR DIG DATAO Bssssssss where ssssssss the binary data string e Enter a Pass or Fail in Table 2 1 Verification Tests 2 3 N Port 2 Disable b 3 Disable 1 B Size Mainframe Rear View E1330 61603 Test Cable E1330A B Figure 2 2 Test Cable Installation 2 4 Verification Tests Example Digital Test 3 Repeat for Ports 1 through 3 Repeat step 2 for ports 1 2 and 3 Use SOUR DIG DATAn Bssssssss and MEAS DIG DATAn where port number and ssssssss the binary string For Port 1 Write use Port 3 Read For Port 2 Write use Port 0 Read For Port 3 Write use Port 1 Read 4 Check Port 0 CTL and Port 2 FLG handshake lines Send RST to the module Send SOUR DIG CONTO 1 to the module Send MEAS DIG FLAG2 to the module Enter the response The response should be 1 Enter a Pass or Fail in Table 2 1 Send SOUR DIG CONTO 0 to the module Send MEAS DIG FLAG2 to the module Enter the response The response should be 0 Enter a Pass or Fail in Table 2 1 5 Repeat for Ports 1 2 and 3 Repeat step 4 for ports 1 2 and 3 Send SOUR DIG CONTn f to the module where port number and f is a binary toggle 0 and 1 Send MEAS DIG FLAGn to the module where n port
12. 1330A B Figure 1 1 shows the Agilent E1330A B Quad 8 Bit Digital I O Module Figure 1 1 Agilent E1330A B Digital I O Module General Information 1 1 Safety Considerations Warnings WARNING This product is a Safety Class I instrument that is provided with a protective earth terminal when installed in the mainframe Check the mainframe Digital I O Module and all related documentation for safety markings and instructions before operation or service Refer to the WARNINGS page page iii in this manual for a summary of safety information Safety information for preventive maintenance testing and service follows and is also found throughout this manual This section contains WARNINGS which must be followed for your protection when performing equipment maintenance or repair SERVICE TRAINED PERSONNEL ONLY The information in this manual is for service trained personnel who are familiar with electronic circuitry and are aware of the hazards involved To avoid personal injury or damage to the instrument do not perform procedures in this manual or do any servicing unless you are qualified to do so CHECK MAINFRAME POWER SETTINGS Before applying power verify that the mainframe setting matches the line voltage and that the correct fuse is installed An uninterruptible safety earth ground must be provided from the main power source to the supplied power cord set GROUNDING REQUIREMENTS Interruption of the protective gro
13. Agilent 75000 Series B Agilent 1330 1330 Quad 8 Bit Digital Input Output Modules Service Manual Enclosed is the Service Manual for the Agilent 1330 1330 Quad 8 Bit Digital Input Output Modules Insert this manual along with any other V XIbus manuals that you have into the binder that came with your Agilent Technologies mainframe HE Agilent Technologies Manual Part Number E1330 90012 Printed in Malaysia E 6 NOTICE In August 2014 Agilent Technologies former Test and Measurement business became Keysight Technologies This document is provided as a courtesy but is no longer kept current and thus will contain historical references to Agilent For more information goto www keysight com KEYSIGHT TECHNOLOGIES Certification Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology formerly National Bureau of Standards to the extent allowed by that organization s calibration facility and to the calibration facilities of other International Standards Organization members Warranty This Agilent Technologies product is warranted against defects in materials and workmanship for a period of one 1 year from date of s
14. corrections may be done without accompanying product changes Therefore do not expect a one to one correspondence between product updates and manual updates Edition 1 Part Number 1330 90010 December 1992 Edition 2 Part Number 1330 90011 November 1994 Edition 3 Part Number 1330 90012 April 1996 Edition 3 Rev 2 Part Number 1330 90012 June 2006 Bafdl 09 00 b3j Safety Symbols Instruction manual symbol affixed to product Indicates that the user must refer to the man Alternating current ual for specific WARNING or CAUTION information to avoid personal injury or dam III age to the product Direct current DC Indicates hazardous voltages Indicates the field wiring terminal that must _ be connected to earth ground before operating t the equipment protects against electrical Calls attention to a procedure practice or con shock in case of fault WARNING dition that could cause bodily injury or death Calls attention to a procedure practice con o Frame or chassis ground terminal typically CAUTION dition that could possibly cause damage to connects to the equipment s metal frame equipment or permanent loss of data WARNINGS The following general safety precautions must be observed during all phases of operation s
15. d damage to the equipment when performing instrument maintenance or repair MAXIMUM VOLTAGE CURRENT The maximum voltage that may be applied between any connector pin and any other point shield or chassis is 5 VPeak STATIC ELECTRICITY Static electricity is a major cause of component failure To prevent damage to the electrical components in the Digital I O module observe anti static techniques whenever working on a Digital I O module General Information 1 3 Digital I O Description NOTE Agilent E1330A B Description Digital I O Module Specifications Digital I O Module Environment The Agilent E1330A B Digital I O Module is an instrument in a VXIbus mainframe As such each Digital I O module is assigned an error queue input and output buffers and a status register Instruments are based on the logical addresses of the plug in modules See the Agilent 75000 Series B Installation and Getting Started Guide to set the addresses to create an instrument The Agilent E1330A B provides four independent 8 bit digital I O ports compatible with TTL logic levels Each port can be software configured for operation as input or output with either positive or negative true logic The ports can be combined to provide 16 bit WORD or 32 bit LWORD operations In addition to the eight digital data lines six handshake lines are included per port The handshake lines can also be combined via jumpers on the component assembly t
16. d of bit walk test Handshake line test End of handshake line test Digital PASSED all tests Verification Tests 2 7 Performance Test Record Test Limits Measurement Uncertainty Test Accuracy Ratio TAR Table 2 1 Performance Test Record 18 a form you and use to record performance verification test results for the Module Agilent E1330A B test is pass fail test and has no test limits Minimum and Maximum values are marked NA Not Applicable in Table 2 1 The Agilent E1330A B test is a pass fail test and has no measurement uncertainty The measurement uncertainty column is marked NA Not Applicable in Table 2 1 Test Accuracy Ratios TAR are not defined for pass fail measurements so all measurements show NA Not Applicable in the TAR column 2 8 Verification Tests Table 2 1 Performance Test Record Page 1 of 2 Report No General Information Test Facility Name Report No Address Date City State Customer Phone Tested by Special Notes Test Record Test Eguipment Used Model No Description Trace No Cal Due Date Verification Tests 2 9 Table 2 1 Performance Test Record Page 2 of 2 Report No Performance Test Record Test No Description Minimum Measured Value Maximum Test Acc Value Value Ratio
17. end IDN to the module see example following 4 The return should be as follows revision number may vary HEWLETT PACKARD E1330A 0 A 06 00 If the primary address setting secondary address setting or the interface select code is set incorrectly the module will not respond Verify proper address selection before troubleshooting Both the Agilent E1330A and Agilent E1330B return the string shown in Step 4 The E1330B will return E1330A in response to the IDN query An example follows which uses an HP 9000 Series 300 computer with BASIC and a module address of 70918 10 DIM A 100 20 OUTPUT 70918 IDN Send the ID command 30 ENTER 70918 A Get response 40 PRINT A 50 END Operation Verification Test The procedures in this section are used to provide a high level of confidence that the module is meeting published specifications The Operation Verification test is a subset of the Performance Verification tests and is suitable for checkout after performing repairs The Operation Verification Test is performed by completing the Digital Test Test 2 1 as described in the Performance Verification test procedures This test is usually sufficient to verify that the module is meeting its specifications 2 2 Verification Tests Performance Verification Tests Test Cable Test 2 1 Digital Test Data Line Test The procedure in this section is used to test the module s electrical performance using the spec
18. er reason REMOVE POWER and do not use the product until safe operation can be verified by service trained personnel If necessary return the product to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained DO NOT service or adjust alone Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present DO NOT substitute parts or modify equipment Because of the danger of introducing additional hazards do not install substitute parts or perform any unauthorized modification to the product Return the product to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained Declaration of Conformity Declarations of Conformity for this product and for other Agilent products may be downloaded from the Internet There are two methods to obtain the Declaration of Conformity e Go to http regulations corporate agilent com DoC search htm You can then search by product number to find the latest Declaration of Conformity Alternately you can go to the product web page www agilent com find E1330B click on the Document Library tab then scroll down until you find the Declaration of Conformity link Agilent 75000 Series B Service Documentation Suggested Seduence to Use Manuals Installation and Getting Started Guide Instru
19. ervice and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the product Agilent Technologies assumes no liability for the customer s failure to comply with these requirements Ground the equipment For Safety Class 1 equipment equipment having a protective earth terminal an uninterruptible safety earth ground must be provided from the mains power source to the product input wiring terminals or supplied power cable DO NOT operate the product in an explosive atmosphere or in the presence of flammable gases or fumes For continued protection against fire replace the line fuse s only with fuse s of the same voltage and current rating and type DO NOT use repaired fuses or short circuited fuse holders Keep away from live circuits Operating personnel must not remove equipment covers or shields Procedures involving the removal of covers or shields are for use by service trained personnel only Under certain conditions dangerous voltages may exist even with the equipment switched off To avoid dangerous electrical shock DO NOT perform procedures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this product have been impaired either through physical damage excessive moisture or any oth
20. es for the Digital I O module Use the steps in Figure 1 2 as guidelines to perform initial inspection of a Digital I O module Performance Verification tests are optional To avoid possible hazardous electrical shock do not perform electrical tests if there are signs of shipping damage to the shipping container or to the instrument 1 6 General Information INITIAL INSPECTION Check Carton E di m ITN Notify Agilent and carrier eo TES Keep carton for carrier inspection A FTN i Inventory Contents Contents ra 2 No Notify Agilent Complete ves j Nuus 5 Install Modul x See Series B Installation Cetting Started Gunder y 5 N Perform vA See Chapter 2 Verification Tests a Verification Tests p cw A N Return Module to HP Pass OM See Shipping Guidelines ves _ Deliver Module to User Optional Figure 1 2 Initial Incoming Inspection Guidelines General Information 1 7 Shipping Follow the steps in Figure 1 3 to return a Digital I O module to Agilent Guidelines Technologies Sales and Support Office or Service Center ANTI STATIC 1 Prepare the Dig
21. fication performance verification adjustment preventive maintenance troubleshooting and repair are also provided What s in this Manual Manual Overview This manual shows how to service the Agilent E1330A B Quad 8 Bit Digital I O Module Consult the Agilent E1330A B User s Manual for additional information on installing configuring and operating the Agilent E1330A B Consult the appropriate mainframe user s manual for information on configuring and operating the mainframe Manual Content Chapter Title Content 1 General Provides a basic description and lists the test equipment required for service Information Verification Functional verification operation verification and performance verification tests Tests Replaceable Lists replaceable parts for the module Parts Service Procedures to aid in fault isolation and repair of the module Table of Contents Agilent E1330A B Service Manual Chapter 1 Introduction ete EE Ede dedu gue 1 1 Safety Consider tions Rd m 1 2 os ALAS SU or Ae PA ae don a a 1 2 4 oed eos Ce duit d mco te oed 1 3 Digital O Description ee 1 4 Agilent E1330A B Description 1 4 Digital I O Module
22. he Buyer s circuitry In addition Agilent does not warrant any damage that occurs as a result of the Buyer s circuit or any defects that result from Buyer supplied products NO OTHER WARRANTY IS EXPRESSED OR IMPLIED Agilent SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Exclusive Remedies THE REMEDIES PROVIDED HEREIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES Agilent SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CON TRACT TORT OR ANY OTHER LEGAL THEORY Notice The information contained in this document is subject to change without notice Agilent Technologies MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Agilent Technologies Inc Agilent assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Agilent U S Government Restricted Rights The Software and
23. hipment Duration and conditions of warranty for this product may be superseded when the product is integrated into becomes a part of other Agilent products During the warranty period Agilent Technologies will at its option either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility designated by Agilent Technologies Buyer shall prepay shipping charges to Agilent and Agilent shall pay shipping charges to return the product to Buyer However Buyer shall pay all shipping charges duties and taxes for products returned to Agilent from another country Agilent warrants that its software and firmware designated by Agilent for use with a product will execute its programming instructions when properly installed on that product Agilent does not warrant that the operation of the product or software or firmware will be uninterrupted or error free Limitation Of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied products or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance The design and implementation of any circuit on this product is the sole responsibility of the Buyer Agilent does not warrant the Buyer s circuitry or malfunctions of Agilent products that result from t
24. ifications in Appendix A Specifications of the Agilent E1330A B Modules User s Manual as the performance standard The Performance Verification test is a test of each Digital I O line on each port and a test of the three main handshake lines for each port This test is sufficient to determine that the module is operating within specifications This test is suitable for incoming inspection troubleshooting and preventive maintenance A test cable is required to run the Performance Verification test This test cable is available from Agilent Technologeis Part Number E1330 61603 This test verifies that all ports meet the specification for the module 1 Setup and Install the Digital O module e Remove power from the mainframe Remove Agilent E1330A B from the mainframe as required Record the locations of the Pull up Enable and any FLG Combine jumpers on the Agilent E1330A B e Set Port and Port 1 Pull up Enable jumpers to the Enable position as shown in Figure 2 1 e Set Port 2 and Port 3 Pull up Enable jumpers to the Disable position as shown in Figure 2 1 Remove any FLG Combine jumpers installed Install the Agilent E1330A B in the mainframe Install the Test Cable as shown in Figure 2 2 Turn the mainframe power ON 2 Check Port 0 Write and Port 2 Read Send RST to the module Send SOUR DIG DATAO B00000001 to the module Send MEAS DIG DATA2 to the module Enter the response and compare to the binary data
25. ital I O module e Remove user wiring from the module e Attach tag to module pod that identifies Owner Model Number Serial Number Service Required e Place tagged device in approved anti static bag 2 Package the Digital I O module Place packaged Digital I O module in shipping carton Place 75 to 100 mm 3 to 4 inches of shock absorbing material around the Digital I O module Seal the shipping carton securely Mark the shipping carton FRAGILE ONSNSWS 3 Ship the Digital I O module to Agilent Technologies e Place address label on shipping carton Shock Absorbing e Send carton to Agilent Technologies Material Figure 1 3 Packaging Shipping Guidelines We recommend that you use the same shipping materials as those used in factory packaging available from Agilent Technologies For other commercially available shipping materials use a double wall carton with minimum 2 4 MPa 350 psi test 1 8 General Information 2 Verification Tests Introduction Test Conditions Procedures Performance Test Record Verification Test Examples This chapter describes the verification tests for the Agilent E1330A B modules The three levels of test procedures described in this chapter are used to verify that the Agilent E1330A B is functional Functional Verification Test e meets selected testable specifications Operation Verification e meets all testable specifications Performance Verification See Tab
26. le 1 1 for test equipment requirements You should complete the Performance Verification tests at least once a year For heavy use or severe operating environments perform the tests more often The verification tests assume that the person performing the tests understands how to operate the mainframe the module and the specified test equipment The test procedures do not specify equipment settings for test equipment except in general terms It is assumed that a qualified service trained technician will select and connect the cables adapters and probes required for the test The results of each Performance Verification test may be recorded in Table 2 1 Performance Test Record at the end of this chapter You can make a copy of this form if desired Each verification test procedure includes an example program that performs the test All example programs assume the following configuration HP 9000 Series 200 300 computer BASIC programming language Module address 70918 Verification Tests 2 1 Functional Verification Test Procedure NOTES Example Functional Verification Test for the Agilent 1330 modules consists of sending the IDN command and checking the response This test can be used to verify that the module is connected properly and is responding to a basic command 1 Verify that the module is properly installed in mainframe 2 Verify that the mainframe has passed its power on test 3 S
27. making repairs to the module inspect the module for any signs of abnormal internally generated heat such as discolored printed circuit boards or components damaged insulation or evidence of arcing Determine and correct the cause of the condition Then perform Test 2 1 as described in Chapter 2 Verification Tests to verify that the module is functional 4 4 Service A Verification Tests C Programs Fu n cti on al This program is designed to do the Functional Verification Test found in Chapter 2 Verification Tests Verification Test Example This example sends a IDN command to the Digital I O Module This test can be used to verify that the module is connected properly and is responding to a basic command include lt stdio h gt include lt sicl h gt define ADDR hpib7 9 18 Address of Device void main INST id Define id as an instrument char a 256 0 Result variable id iopen ADDR Open instrument session ipromptf id IDN W t a ID command printf n 96s a Print result getchar Pause iclose id Close instrument session Example Programs 1 Pe rformance This program is designed to do the Performance Verification Test found in Ve rifi cat i on Chapter 2 Verification Tests Test Example This example performs a bit walk test of all bits on all ports and checks the Dig ital Test
28. ment Applications Using the Mainframe Module rame anuals anuals Repairing the Mainframe Plug in Module Mainframe Service Manuals Service Manual Manual Descriptions Installation and Getting Started Guide This manual contains step by step instructions for all aspects of plug in module and mainframe installation Introductory programming information and examples are also included Mainframe User s Manual This manual contains programming information for the mainframe front panel operation information for the Agilent E1301B mainframe and general programming information for instruments installed in the mainframe Plug In Module User s Manuals These manuals contain plug in module programming and configuration information Each manual contains examples for the most used module functions and a complete SCPI command reference for the plug in module Mainframe Service Manual This manual contains service information for the mainframe It contains information for ordering replaceable parts and exchanging assemblies Information and procedures for performance verification adjustment preventive maintenance troubleshooting and repair are also included Plug In Module Service Manuals These manuals contain plug in module service information Each manual contains information for exchanging the module and or ordering replaceable parts Depending on the module information and procedures for functional verification operation veri
29. nes for repairing and maintaining the Agilent E1330A B Quad 8 Bit Digital I O Module including e ESD precautions e Soldering printed circuit boards e Post repair safety checks Electrostatic discharge ESD may damage static sensitive devices in the module This damage can range from slight parameter degradation to catastrophic failure When handling the module observe the following guidelines Always use a static free work station with a pad of conductive rubber or similar material when handling module components f a device requires soldering be sure the assembly is placed on a pad of conductive material Also be sure that you the pad and the soldering iron tip are grounded to the assembly The etched circuit board of this module has plated through holes that provide a solder path to both sides of the insulating material Soldering can be done from either side of the board with equally good results When soldering to any circuit board keep in mind the following guidelines Avoid unnecessary component unsoldering and soldering Excessive replacement can result in damage to the circuit board adjacent components or both Do not use a high power soldering iron on etched circuit boards as excessive heat may lift a conductor or damage the board Use a suction device or wooden toothpick to remove solder from component mounting holes When using a suction device be sure that the equipment is properly grounded After
30. o provide proper handshaking for combined ports The data lines of each port are provided with a jumpered pull up for dry contact closure sensing User connections to the Digital I O module are made through two 60 pin connectors on the rear panel The Agilent E1330B added SCPI command capabilities related to LWORD and Block operations The procedures in this manual work equally well with either an Agilent E1330A or Agilent E1330B See Appendix A of the Agilent E1330A B User s Manual for Agilent E1330A B specifications These specifications are the performance standards or limits against which the instrument may be tested The recommended operating environment for the Agilent E1330A B Digital I O module is Environment Temperature Humidity Operating 0 C to 55 C lt 65 relative 0 C to 40 C Storage and 40 C to 75 C lt 65 relative 0 C to 40 C Shipment 1 4 General Information Digital I O Module Serial Numbers Digital I O Module Options Digital VO modules covered by this manual are identified by serial number prefix listed on the title page Agilent Technologies uses a two part serial number in the form XXXXAY YYYY where XXXX is the serial prefix A is the country of origin A USA and Y Y YYY is the serial suffix The serial number prefix identifies a series of identical instruments The serial number suffix is assigned sequentially to each instrument The serial number plate is located on
31. of bit walk printf n WRITE at port 9eu j if j lt 2 printf n READ at port u j 2 else printf n READ at port u j 2 printf n nHandshake line test j 1 gt 0 1 for i 0 i lt 3 i iprintf id SOUR DIG CONT u i j if i lt 2 iprintf id MEAS DIG FLAG u n 2 else iprintf id MEAS DIG FLAG u n i 2 iscanf id 1t a if atoi a j fail 1 printf nFailure of handshake lines if i lt 2 printf n CTL line on port u to FLG line on port i i 2 else printf n CTL line on port u to FLG line on port i 1 2 Example C Programs A 3 printf nEnd of handshake line test n if fail 0 printf nDigital I O PASSED all tests else printf nDigital I O failed tests iclose id Close instrument session A 4 Example C Programs
32. ont panels To replace or more of these old parts you must order all three new parts Top and Bottom Handle Kits AND Front Panel 3 2 Replaceable Parts Reference Designator 1 1 CBL2 CBL3 P51 P57 PNL1 SCR1 SCR2 SCR3 SCR4 SCR5 SCR6 SW1 Agilent Part Number E1330 66202 1330 66521 1330 61603 1330 61601 1300 451011 1300 451021 2110 0712 1252 1044 1251 6515 1251 4927 1251 4682 1252 1596 1258 0247 1258 0141 1330 002121 0515 2140 0515 1968 0515 2743 3101 3066 Table 3 2 Agilent E1330B Replaceable Parts Part Description ASSEMBLIES and CABLES See Figure 3 1 REPLACEMENT ASSEMBLY PC Assembly Digital I O 32 Channel Test Cable issued with Service Kit Ribbon Cable not illustrated HNDL KIT TOP Agilent HNDL KIT BTM VXIT Fuse subminiature 4A 125V NTD AX Connector post type 100 pin spcg 60 contact Connector post type 100 pin spcg 6 contact Connector post type 100 pin spcg 16 contact Connector post type 100 pin spcg 3 contact Connector post type 2 54 pin spcg 96 contact Four position Jumper Removable Jumper PNL RR 4 CH DACT SCR THD RLG 2 5 X0 45 14mm Screw M2 5 X 0 45 11mm long pan head SCR FH M2 5 X 8 THREAD ROLLING Switch dip Rocker 8 1A 0 15A 30 VDC Mfr Part Number E1330 66202 1330 66521 1330 61603 1330 61601 1300 451011 1300 451021 R251004T1 3372 5302 67996 606 2416 6182TB 22 10 2031 536010 5 69146 204 530153 2
33. shaking for combined ports The data lines of each port are provided with a jumpered pull up resistors for dry contact closure sensing User connections to the Digital I O module are made through two 60 pin connectors on the rear panel Service 4 1 r St rategy Agilent Technologies recommends replacement of the entire assembly in the event of a failure Procedures in this chapter describe troubleshooting techniques Tro u b les h ooti n g To troubleshoot an Agilent E1330A B module problem you must first Techniques Identifying the Problem Making Visual NOTE Checks identify the problem and then isolate the cause of the problem to a replaceable assembly See Chapter 3 Replaceable Parts for descriptions and locations of Agilent E1330A B replaceable parts Table 4 1 lists some common problems for the Agilent E1330A B modules along with symptoms and possible solutions If the problem cannot be identified using these steps replace the assembly Table 4 1 Agilent E1330A B Typical Problems Symptom Possible Solutions Non zero error code in See Appendix A of the Agilent response to SYST ERR E1330A B Quad 8 Bit Digital I O Module User s Manual Module not responding to See Making Visual Checks in this commands chapter Module fails Digital Test See Testing the Module in this Test 2 1 chapter Visual checks for the Agilent E1330A B modules include the following See Table 4 2 for t
34. the backplane connector If the serial number prefix of your instrument is greater than the one listed on the title page a Manual Update as required will explain how to adapt this manual to your instrument There are no electrical or mechanical options available for the Agilent E1330A B Digital I O Modules General Information 1 5 Recommended Test Equipment Table 1 1 lists the test equipment recommended for testing adjusting and test equipment are described in the Requirements column Table 1 1 Recommended Test Equipment servicing the Digital I O modules Essential requirements for each piece of Instrument Requirements Recommended Use Model Controller GPIB GPIB compatibility as defined by IEEE HP 9000 Series 300 F O Standard 488 1987 and the identical or ANSI Standard MC1 1 SH1 AH1 2 IBM compatible PC with TEO L2 LEO SR0 RLO PP0 DCO BASIC C1 2 3 4 5 Mainframe Compatible with Digital I O Module Agilent E1300A F O E1301A E13002A or 1401 1421 requires E1405A B Test Cable Connects handshake and data lines Agilent E1330 61603 from Port 0 to Port 2 and from Port 1 to Port 3 F Functional Verification Tests O Operation Verification Tests P Performance Verification Tests T Troubleshooting Inspection Shipping Initial Inspection WARNING This section contains initial incoming inspection and shipping guidelin
35. unding conductor inside or outside the mainframe or disconnecting the protective earth terminal will cause a potential shock hazard that could result in personal injury Grounding one conductor of a two conductor outlet is not sufficient protection IMPAIRED PROTECTION Whenever it is likely that instrument protection has been impaired the mainframe must be made inoperative and be secured against any unintended operation REMOVE POWER IF POSSIBLE Some procedures in this manual may be performed with power supplied to the mainframe while protective covers are removed Energy available at many points may if contacted result in personal injury If maintenance can be performed without power applied the power should be removed 1 2 General Information WARNING Cautions CAUTION USING AUTOTRANSFORMERS If the mainframe is to be energized via an autotransformer for voltage reduction make sure the common terminal is connected to neutral that is the grounded side of the main s supply CAPACITOR VOLTAGES Capacitors inside the mainframe may remain charged even when the mainframe has been disconnected from its source of supply USE PROPER FUSES For continued protection against fire hazard replace the line fuses only with fuses of the same current rating and type such as normal blow time delay etc Do not use repaired fuses or short circuited fuseholders This section contains CAUTIONS which must be followed to avoi
36. ypical checks Check switches jumpers Check for heat damage Check connector contacts See the Agilent E1330A B Quad 6 Bit Digital I O Module User s Manual for information on logical address and IRQ settings If there are no apparent problems following the visual checks run the Performance Verification Tests in Chapter 2 to see if the module is defective 4 2 Service Test Check Heat Damage Table 4 2 Agilent E1330A B Visual Tests Checks Reference Designator Discolored PC boards Damaged insulation Evidence of arcing Action Notes l there is damage do not operate the module until you have corrected the problem Switch Jumper Settings J15 J16 SW1 J51 J52 J53 J54 J12 IRQ Level setting Logical address setting Pull up Enable FLG Combine Factory set at 1 Factory set at 144 Factory set to Enable Factory set to no jumpers Component Assembly F1 J1 J2 P1 Fuse continuity Dirty or bent connector pins Dirty or bent connector pins Check fuse with ohmmeter Straighten clean pins Straighten clean pins Testing the Module You can use the tests and checks in Chapter 2 Verification Tests to identify a problem with the assembly See Chapter 3 Replaceable Parts for locations of mechanical parts Service 4 3 Repair and Maintenance Guidelines ESD Precautions Soldering Printed Circuit Boards Post Repair Safety Checks This section provides guideli

Download Pdf Manuals

image

Related Search

Related Contents

Moniteur Wattbike Mode d`emploi    取扱説明書 - Panasonic  Microsoft Xbox 360 Pro System Console  C-10/C-20  Pando P-402  TN245 Client-Side SSL Workaround Using Rabbit Server  Service Manual For  Oracle9iAS TopLink Troubleshooting Guide    

Copyright © All rights reserved.
Failed to retrieve file