1. zinc 1 pc hexagon nut DIN 934 MS zinc 6 RightSight bracket 60 2649 mounting hardware 2 pcs Hexagon socket head cap screw DIN 912 M6x 14mm 0 55 in 2 pcs T slot nut 6 steel M6 zinc plated Optional parts for muting not supplied 8 RightSight retroreflective sensor 42EF P2MPB Y4 7 RightSight swivel tilt bracket 60 2649 4 pin straight DC micro QD patchcord 889D F4ABPM X X is length in meters not shown 5 Large reflector 92 39 76 mm 3 in diameter or small reflector 92 47 32 mm 1 25 in diameter Step 2 Assemble 500 mm cantilever post Slide the four universal fastening sets in each slot on the left or the right side of floor mounting stand Place the lower universal fastening sets at the desired height Make sure that the bezels of the lower universal fastening sets are on the upside Place the upper universal fastening sets about 100 mm higher than the lower ones Make sure that the upper bezels of the universal fastening sets are on the underside AB Allen Bradley 4 Original instructions Guard marte Floor Mounting Stand and Cantilever User Manual Step 3 Securing 500 mm cantilever to post Hold the cantilever profile between the universal fastening sets Using a 4 hex tool tighten the hex head screws i Step 4 Installing muting sensors and reflectors Mount the muting sensor to the bracket Mount the muting sensor and the bracket to the slot in the extrusion using the su
2. Floor Mounting Column and Allen Bradley Cantilever User Manual Guardimaste Rockwell Allen Bradley Rockwell Software Automation Important User Information Because of the variety of uses for the products described in this publication those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements including any applicable laws regulations codes and standards The illustrations charts sample programs and layout examples shown in the guide are intended solely for purposes of example Since there are many variables and requirements associated with any particular installation Rockwell Automation does not assume responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication Rockwell Automation publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation sales office describes some important differences between solid state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication Reproduction of the contents of this copyrighted publication in whole or part without written permission of Rockwell Automation is prohibit
3. c hexagon socket head cap screws DIN 912 M6 x 25 mm 0 98 in Zinc washer flat M6 x 12 mm 0 47 in Zinc set screw DIN 913 M12 x 12 mm 0 47 in Aluminum black anodized floor mounting plate Micro 400 bracket hardware bracket not included Zinc plated T slot nut 6 steel M4 Hexagon socket head cap screw DIN 912 M4x 14mm 0 55 in Brackets 445L AF6145 Micro 400 flat bracket not included Safe 4 bracket 445L AF6140 hardware bracket not included Zinc plated T slot nut 6 steel M6 Hexagon socket head cap screw DIN 912 M6 x 20 mm 0 79 in Brackets 445L AF6140 Safe 2 4 bracket not included Muting box hardware muting box not included Zinc plated T slot nut 6 steel M5 Zinc washer flat M5 x 10 mm 0 39 in Hexagon socket head cap screw DIN 912 M5 x 12 mm 0 47 in Cover profiles for hiding cables aluminum 300 mm 11 8 in Profile top cap 60 x 60 mm 2 4 x 2 4 in Position the floor plate to the bottom of the two meter post with the recessed holes opposite the post Premount the screws with the washer in the holes of the floor plate For use as a muting system assemble WOLU cantilevered arms prior to installing the floor mounting plate AB Allen Bradley H Guard Imaster Floor Mounting Stand and Cantilever User Manual Step 3 Leveling hardware Three hexagon socket head cap screws are supplied to level the floor plate If necessary premount these screws before attaching the f
4. ed Throughout this manual we use notes to make you aware of safety considerations Identifies information about Ha Or circumstances that can cause an explosion in RE a hazardous environment which may lead to personal injury or death property N damage or economic loss Identifies information that is critical for successful application and understanding of edital the product Identifies information about practices or circumstances that can lead to personal injury or death BLER damage or economic loss Attentions help you identify a A hazard avoid a hazard and recognize the consequences Labels may be on or inside the equipment for example drive or motor to alert people that dangerous voltage may be present SHOCK HAZARD A Labels may be on or inside the equipment for example drive or motor to alert people that surfaces may reach dangerous temperatures It is recommended that you save this user manual for future use Introduction The Allen Bradley Guardmaster aluminum mounting stand is offered in a two meter length and is supplied with a floor mounting plate and the hardware necessary to mount the floor plate to the aluminum extrusion as well as leveling hardware for the floor plate The two meter aluminum extrusion has a cross section of 60 x 60 mm 2 36 x 2 36 in The two meter mounting stand is designed for mounting safety light curtains corner mirrors and the 445L muting box The two meter mountin
5. g stand can also be used for entry and exit end muting A 500 mm long 60 x 60 mm aluminum section is offered with mounting hardware and a black end cap cover One section attached to the two meter mounting stand allows an L type two sensor muting solution two 500 mm sections allow for two or four sensor T type muting The slots in the extrusion allow easy assembly and positioning of muting sensors and reflectors Light Curtain Nae f an L or T type configuration is GuardShield Micro 400 planned it is best to assemble the 500 mm Safe 2 Safe 4 or 440L Micro 400 example sections to the two meter post prior to installing the floor plate Muting Controller Box MSR42 445L AMUTBOX1 pe Mounting Stand Reflector a Cantilever Muting Sensor Floor Mounting Plate included with mounting column Safe 4 example Figure Mounting stand used for safety light curtain in a muting system Allen Bradley Original instructions a 6 Guard Fmaster Floor Mounting Stand and Cantilever User Manual 445L AMSTD2M Floor Mounting Stand Step 1 Supplied parts Step 2 Assembling floor plate to post 2 Original instructions Pos Qty 1 pe 2 4 pes 6 pcs 3 pes 4 1 pe 2 pcs 2 pcs 6 7 2 pcs 2 pcs 8 9 2 pcs 2 pcs 2 pcs Not shown 4 pes l pcs Description Profile 60 x 60 x 2000 mm 2 4 x 2 4 x 78 7 in Floor plate to extrusion mounting hardware Zin
6. loor plate to the aluminum post Step 4 Install profile covers Four 300 mm profile covers are supplied with each two meter post to hide the cables Install these after the cables are assembled and connected Use a rubber mallet to secure these profile covers to the two meter post b Step 5 Leveling the two meter post kit When the floor plate is positioned and loosely secured to the floor adjust each leveling screw to assure the two meter post is attached to the floor Then tighten the floor plate to the floor a A A Allen Bradley Original instructions 3 a 6 Guard Fmaster Floor Mounting Stand and Cantilever User Manual 445L AMSTDMUT Cantilever Assembly Steps Step 1 Supplied parts Pos Qty Description 1 Ipc Aluminum profile 60 x 60 x 500 mm 2 4 x 2 4 x 19 7 in l pc Black end cap 60 x 60 2 Ipc Aluminum cover profiles for hiding cables 300 mm 11 8 in 1 3 To attach cantilever post to the floor stand post 4 pcs Stainless steel universal fastening set 6 item no 0044174 4 1pc Mounting kit for reflector reflector not supplied 1 pc bracket 80 x 40 x 20 Zn Item No 0047463 Bracket mounting hardware 1 pc washer flat M6 x 12 mm 0 47 in zinc 1 pc hexagon socket head cap screw DIN 912 M6x 16 mm 0 63 in 1 pc T slot nut 6 steel M6 zinc plated Reflector mounting hardware 1 pc hexagon socket head cap screw DIN 912 M5 x30 mm 1 18 in 1 pc washer flat M5 x 10 mm 0 39 in
7. pplied hardware Step 5 Installing reflector Mount the reflector to the supplied bracket Mount the bracket to the extrusion slot using the supplied hardware Position the reflector and tighten bracket hardware Allen Bradley Original instructions 5 Guard maste Floor Mounting Stand and Cantilever User Manual Step 6 Mount cover profiles positioning the profile covers Using a rubber mallet or a block of material a Run cables in the slots once the system is complete Finish the assembly by that will not damage the material lightly tap the cover profiles in place Dimensions mm in 20 0 79 defined at installation cover for cable locate appropriately 60 2 36 12 0 47 Base Plate 6 Original instructions Allen Bradley H Guard Imaster Floor Mounting Stand and Cantilever User Manual D Allen Bradley Original instructions 7 Guard maste Floor Mounting Stand and Cantilever User Manual 8 Original instructions Allen Bradley H Guard Imaster Floor Mounting Stand and Cantilever User Manual D Allen Bradley Original instructions 9 Guard maste GuardShield is a trademark of Rockwell Automation Inc www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automa
8. tion Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 10000127396 Ver 01 Copyright 2011 Rockwell Automation Inc All Rights Reserved Printed in USA July 2011

Download Pdf Manuals

image

Related Search

Related Contents

平成26年度諫早市ボランティアセンター登録団体 (情報公開団体のみ)  Instruction Manual  NE-9000 Peristaltic Pump User Manual  Descargar  HP Sprinkler 54510A User's Manual  Exceleram ES0060S solid state drive  Serie Satellite 1800  Philips CDR-795 CD Player User Manual  JVC GR-FX14 Camcorder User Manual  Samsung SyncMaster S27A750D User Guide Manual  