Informer Compact Series LINE-INTERACTIVE
Contents
1. Low LIL 14 a he Se Tr es a Yv Sa AA A ier H 1 Utility LED LINE 2 Fault LED A 3 On Switch 4 0ff Switch O 5 Battery Replacement LED 6 Battery Backup LED C 7 Battery Low C 8 Bypass 9 Utility Low UPS Boost 10 Utility High UPS Buck gt 11 UPS Output Indicator LOAD 12 Polarity Error Ground Fault 13 Over load 3 14 Load Battery Level tu 15 Load Battery Level Indication Control Button gt 1 RJ45 Port 2 DIP Switch 3 RS232 Communication Port 4 Outlet 5 Rating Label 6 Input Fuse 7 Input Power Cord Inlet 8 USB Port 10 DIP SWITCH SETTING The voltage of the UPS might be re set by the DIP Switch on the rear panel of the UPS The following charts may bring you clear pictures about how the settings are done by the DIP Switch FUNCTION VOLTAGE 220V Hora N A VOLTAGE 230V 4 4_ VOLTAGE 240V lt 11 INDICATORS AND ALARMS Replacement Indicator Color Description Alarm Utility Mode Green Steady None A LINE Output Load is supplied by Utility Backup Mode Amber Steady with alarm Every 2 seconds Output Load is supplied by Battery before battery Low and every 1 second before battery Cutoff Fault Red When Overload short circuit or Buzzer beeps A z Output Voltage Abnormal occurs continuo
2. Informer Compact Series LINE INTERACTIVE SINEWAVE UPS Uninterruptible Power System 1kVA 2kVA 3kVA USER MANUAL inform IMPORTANT SAFETY INSTRUCTIONS WARNING SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please follow up all instructions carefully during installation Read this manual thoroughly before attempting to unpack install or operate CAUTION To prevent the risk of fire or electric shock please install the unit in a temperature and humidity controlled indoor area which is free of conductive contaminants CAUTION risk of electric shock do not remove the cover No user serviceable parts Refer servicing to qualified service personnel CAUTION Risk of electric shock Hazardous live parts inside this UPS can be energized from the battery supply even when the input AC power is disconnected CAUTION Risk of electric shock Battery Circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Please test it before touching WARNING This is a Class A UPS Product In a domestic environment this product may cause radio interference in which case the user may be required to take additional measures NOTICE The UPS is designed to be for use with computer loads only 1 INSPECTION Inspect the UPS upon receipt Notify the carrier and dealer if there is damage The package is recyclable save it for reuse or dispose of it
3. e for at least 8 hours every 3 months to avoid from battery self over discharge naturally if the UPS is in an idle condition Auto Restart The UPS will automatically restart to provide energy to the output if the utility recovers in 24 hours after battery cut The Backup LED will flash every 5 seconds under the waiting situation On the contrary the UPS will not auto restart if the Utility doesn t recover within 24 hours You are required to start up the UPS manually If you don t need UPS auto restart you can turn off the UPS by proceeding the Turn Off procedure Alarm Silence The Alarm might be turned off by pushing the On Switch for approximately 1 second in the Backup mode Unless any other warning or fault condition occurs the alarm remains at Silence condition once the Alarm Silence is turned off Test Under Utility Normal condition push the On Switch for 3 seconds to execute the Battery Self test function In case the battery is normal it will enter into Battery Backup Mode for 10 seconds then return back to Utility Mode If the battery voltage is detected lower than set limit the Battery Replacement LED will blink for 5 seconds then extinguish to stop self test procedure And if battery is detected weak or dead the Battery Replacement LED will steadily illuminate 8 FRONT PANEL EXPLANATIONS 6 71 8 9 10 11 12 5 132 oe ara ENE T7 G lt 1 0 gt 3e INE UBB LOAD wir gt
4. lid Amber LED and the buzzer alarms every 2 seconds in case of blackout or over under voltage Caution 1 The UPS On will not be executed if the above procedure is not done completely which means the buzzer will be heard 2 The UPS will remain at NO output if the start up operation is not proceeded properly even though the Input Power Cord is connected to the wall receptacle IMPORTANT NOTICE Plug the UPS into the wall receptacle to charge the UPS for over 8 hours after initial installation STORAGE Store at 15 to 30 C 5 to 86 F charge the UPS battery every six months Store at 30 to 45 C 86 to 113 F charge the UPS battery every three months 7 OPERATION TEST Turn Off the UPS Push the Off Switch for at least 3 seconds to turn off the UPS If you press the Off Switch less than 3 seconds the UPS will not execute shutdown command due to insufficient pressing time 5 In some occasions the UPS will shut itself down in case of overload output short circuited or battery cutoff point reached in the Backup mode The UPS will automatically shut off the output and beep for 5 seconds then completely shut itself down Plug in Charge If the Input Power Cord is connected to the wall receptacle properly and the utility is normal the UPS will start to charge automatically without processing Turn On procedure This is indicated by a flashing amber color LED You have to charg
5. properly 2 PLACEMENT 3 LOAD CONNECTION First connect the UPS with Utility then plug the loads into the outlets on the rear of the UPS To use the UPS as a master On Off switch make sure that all of the loads are switch On These UPS outlets provide battery power and surge protection to the equipment when utility voltage is outside acceptable limits Caution Do not connect a laser printer to the outlets 4 CONNECTION OF TELEPHONE NETWORK SURGE PROTECTION Connect a 10 base T 100 base T network cable into the RJ 45 network surge protection IN jack on the rear panel of the UPS Connect from the OUT jack with network cabling to network equipment 5 CONNECTION OF COMPUTER INTERFACE PORT Connect the supplied interface cable RS 232 to the interface port on the rear of the UPS through the computer interface port See software installation guide in the CD ROM Optional for installation purpose 6 START UP 1 Connect the UPS to the wall receptacle and wait app 5 6 sec amber color LED should flash indicating the charging 2 Push the On Switch on the front panel of the UPS until Buzzer sounds then release it 3 The LCD Display lights up along with an LED If Utility is normal the UPS will run under Utility mode Green LED On the contrary the UPS will run under Backup mode So
6. usly Charging Amber Blinking every second no alarm None Mode battery charge utility available Battery Red Steady Battery is dead None