FactoryTalk EnergyMetrix Software Version 2.10.00 Release Notes
Contents
1. any other tab and the data is populated in the fields Real time Viewer Harmonic graph does not display positive and negative values When a power monitor has both positive and negative harmonic values unless the correct order of selection is done with the parameters the harmonic values are not displayed correctly System Status Logged in uses show no entries During normal navigation through FactoryTalk EnergyMetrix software if you click on the Systems tab then click on the Logged in User tab sometimes there are no entries Rate Schedule Season tab displays invalid warning message When the month entered is above 12 the system displays a message stating Start date is invalid but it is the start month that is incorrect When a new season name is given as the same name as that of an existing one in the list the error message is not understandable for the end user Currently you can add a different season name witha same set of values Also the seasons can be overlapped which is not true PowerMonitor 5000 RT Viewer Test Wiring Diagnostics does not work The Perform Test button in the Wiring Diagnostics tab currently does not work Currently the test has to be started from the PowerMonitor 5000 webpage instead Waveform for PowerMonitor 5000 DeviceNet and ControlNet only shows the first 30 cycles Because of bandwidth concerns only the first 30 cycles of waveform for the DeviceNet and ControlNet versi
2. Release Notes Rockwell Software FactoryTalk EnergyMetrix Software Version 2 10 00 Catalog Number 9703 Topic About This Publication Page 1 Package Contents 1 Upgrading or Updating FactoryTalk EnergyMetrix Software Enhancements with Version 2 10 00 w Corrected Anomalies with Version 2 10 00 Known Anomalies with Version 2 10 00 gt Additional Resources About This Publication These release notes describe software enhancements and anomalies for the FactoryTalk EnergyMetrix software version 2 10 00 IMPORTANT FactoryTalk EnergyMetrix software supports only FactoryTalk Activations If you are upgrading from RSEnergyMetrix software activated with EvRSI master disk activation please contact your local Allen Bradley distributor Rockwell Automation sales representative or Technical Support for information to migrate your activations to FactoryTalk activations Package Contents FactoryTalk EnergyMetrix software is an upgrade and re branding of RSEnergyMetrix software The contents of the software product packaging includes the following e The installation DVD contains only FactoryTalk EnergyMetrix Manager software Options such as Real Time RT ReportsPlus ChartsPlus and FTEMOPC third party OPC client are furnished with a FactoryTalk Activation only To install these options install their activations by using Factorylalk Activation Manager e The User Manual replaces the G
3. additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit http www rockwellautomation com support Installation Assistance If you experience a problem within the first 24 hours of installation review the information that is contained in this manual You can contact Customer Support for initial help in getting your product up and running United States or Canada 1 440 646 3434 Outside United States or Canada Use the Worldwide Locator at http www rockwellautomation com support americas phone_en html or contact your local Rockwell Automation representative New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve thi
4. another machine SQL Server 2005 or 2008 Express Edition must also be installed on the FactoryTalk EnergyMetrix server Scheduling auto run reports Scheduling many auto run reports to run at the same time can cause excessive server resource demand and cause reports to time out Viewing reports in web browser Reports run automatically in Excel format cannot be viewed in the web browser if the client has the Microsoft Office 97 operating system or later installed The report can still be saved and opened by using Microsoft Excel software New OPC meter set up When setting up a new OPC meter the first time the OPC Browser is used it can return an error To work around this save the meter with a blank access path edit and click OPC Browser again Validate button in MPR script editor page With IIS 7 clicking the Validate button gives a page error and doesn t validate the script A script with syntax errors can be saved To correct this open IIS Manager from Administrative Tools Drill into Application Pools and change the Managed Pipeline Mode in the default application pool to Classic from Integrated Roll up server functionality requires IE WebControls To utilize roll up server functionality Internet Explorer WebControls 1 0 must be installed on the server The installer for WebControls is provided on the FactoryTalk EnergyMetrix install DVD or install media Rockwell Automation Publication FIEM RNOO2A EN P Febr
5. d PowerMonitor Test Connection CORRECTED The Test COnnection button on the Device Setup page would sometimes display a failure even though there was a successful connection and vice versa ChartsPlus Chart Manager CORRECTED Attempting to load a chart from the ChartsPlus Chart Manager when no chart was selected caused an error RT Activation CORRECTED The RT activation missing message referenced RSEnergyMetrix software instead of FactoryTalk EnergyMetrix software Known Anomalies with The following are the known anomalies for FactoryTalk EnergyMetrix software Version 2 10 00 version 2 10 00 Known Anomaly Description RT Device configuration for the PowerMonitor 3000 unit RT Device configuration dialog box for the PowerMonitor 3000 unit needs to be closed and re opened following an initial upload to enable all the model related features in the dialog box Communication loss to PowerMonitor W250 unit FactoryTalk EnergyMetrix software version 2 0 does not detect communication loss to wireless PowerMonitor W250 units In case of communication loss energy and demand data is not logged and voltage and current data remains fixed Manually adding IP addresses of Ethernet network devices You must manually add the IP address of each Ethernet network device to the RSLinx Classic software Ethernet Devices driver on the server RSLinx Classic software user interface When RSLinx Classic software runs a
6. etting Results Guide and is provided on the installation DVD as an Adobe Acrobat PDF file e Manager products bundled with Microsoft SQL server are supplied with Microsoft SQL Server 2008 R2 Rockwell Allen Bradley Rockwell Software Automation 2 FactoryTalk EnergyMetrix Software Version 2 10 00 Upgrading or Updating FactoryTalk EnergyMetrix Software You can upgrade to FactoryTalk EnergyMetrix from RSEnergyMetrix software or update your FactoryTalk EnergyMetrix 2 x software to the latest version For customers who have purchased software support agreements these updates are available at no charge You can download an upgrade from the Rockwell Software updates page or request a DVD from Rockwell Software support IMPORTANT Ifyou are upgrading from RSEnergyMetrix software activated with EvRSI master disk activation please contact your local Allen Bradley distributor Rockwell Automation sales representative or Technical Support for information to migrate your activations to FactoryTalk activations An upgrade can be installed from a DVD or a downloaded upgrade file The downloaded file is a full image of the installation DVD and is approximately 2 GB in size During an upgrade FactoryTalk EnergyMetrix software reads configuration parameters from the existing web config file and stores them in the database ATTENTION If your installation of FactoryTalk EnergyMetrix software has been A customized by a solution provider Rock
7. ment Accelerator Toolkit for Monitoring and Analysis Integrated Architecture Accelerators Provides system design programming and analysis tools to assist in rapid development and deployment of an energy monitoring analysis and control system Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Provides general guidelines for installing a Rockwell Automation industrial system Product Certifications website http www ab com Provides declarations of conformity certificates and other certification details You can view or download publications at http www rockwellautomation com literature To order paper copies of technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative Rockwell Automation Publication FIEM RNOO2A EN P February 2014 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http www rockwellautomation com support you can find technical manuals technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools You can also visit our Knowledgebase at http www rockwellautomation com knowledgebase for FAQs technical information support chat and forums software updates and to sign up for product notification updates For an
8. nel Add Remove Programs application to remove FactoryTalk EnergyMetrix software Then re start the FactoryTalk EnergyMetrix software installer and install the new version The existing installation of FactoryTalk EnergyMetrix software is removed The database is not removed 7 When the un installer completes run setup exe again 8 When prompted enter the SQL system administrator account login credentials You see a message that the existing FactoryTalk EnergyMetrix database has been found and updated if needed The installer copies program options from the previous web config file into the database 9 When prompted click Yes to restart the server IMPORTANT The URL for the web site that FactoryTalk EnergyMetrix software runs under is different from that which RSEnergyMetrix software used The web site name is FTEnergyMetrix instead of RSEnergyMetrix Users that had bookmarked RSEnergyMetrix in their browser need to change that bookmark The following product enhancements are part of FactorTalk EnergyMetrix software version 2 10 00 Enhancement Description New product support FactoryTalk EnergyMetrix software supports the Allen Bradley PowerMonitor 5000 M6 unit PowerMonitor 5000 FactoryTalk EnergyMetrix software supports ControlNet for connecting to Allen Bradley ControlNet PowerMonitor 5000 units SEMI F47 0706 2006 Standard Added SEMI F47 0706 2006 standard to the PowerMonitor 5000 and Powe
9. on of the PowerMonitor 5000 unit is downloaded into FactoryTalk EnergyMetrix software If the full waveform is needed you can connect to the power monitor by using a USB cable Waveform not automatically deleted for PowerMonitor 5000 DeviceNet and ContolNet meters Because FactoryTalk EnergyMetrix software only downloads the first 30 cycles the system leaves the waveforms on the power monitor The waveforms have to be manually deleted from the RT Viewer Waveform tab PowerMonitor 5000 Trigger data log displays invalid value when logic inputs 1 and 4 are inverted Trigger data log displays invalid value when Logic Gate Inputs 1 and d4are inverted Rate Schedules Holidays data is incorrectly displayed with the print option Additional Resources When weekday is selected by using the By Day feature day is displayed incorrectly in the print report The weekday is incorrectly calculated based on the number instance in the month instead of the weekday number This has no effect on how the rate schedule is actually used within the billing and cost allocation system This is only an issue in the print report for the rate schedule These documents contain additional information concerning related products from Rockwell Automation Resource Description FactoryTalk EnergyMetrix Software Version 2 10 00 User Manual publication FTEM UM002 Provides information for using FactoryTalk EnergyMetrix software Energy Manage
10. rMonitor 3000 Sag Swell graph chart PowerMonitor 5000 3D Harmonics Added new PowerMonitor 5000 M6 Harmonics viewer with multiple channel display in 3D bar graph PowerMonitor 5000 Larger Waveforms Added new PowerMonitor 5000 M6 Waveform viewer with support for larger Waveform files displayed as multiple segments Power Quality Summary page Added new PowerMonitor 5000 M6 Power Quality Event Summary page with all waveforms grouped by event type and with support for larger Waveform files ADR Wizard on DVD Adding the ADR Wizard directly to the DVD so it can be run separately on not necessarily only from the FactoryTalk EnergyMetrix server Rockwell Automation Publication FIEM RNOO2A EN P February 2014 4 FactoryTalk EnergyMetrix Software Version 2 10 00 Corrected Anomalies with Version 2 10 00 The following product changes were included when the product shipped to you Corrected Anomalies Description Tag address character CORRECTED Meter Tags would only allow 50 characters for the tag address This has been length expanded to 255 characters to acommodate larger OPC and FactoryTalk LiveData tag addresses Deleting Domain CORRECTED Deleting a Domain that had a custom page link would cause an error PowerMonitor 5000 Test Connection CORRECTED The PowerMonitor 5000 Test Connection button on the Device Setup page always returns successful if PowerMonitor 5000 security is not enable
11. s document complete this form publication RA DU002 available at http www rockwellautomation com literature Allen Bradley Rockwell Softwate Rockwell Automation PowerMonitor RSLinx and FactoryTalk are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A S Kar Plaza Merkezi E Blok Kat 6 34752 erenk y stanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation NV Pegasus Park De Kleetlaan 12a 1831 Diegem Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication FIEM RNOO2A EN P February 2014 Copyright 2014 Rockwell Automation Inc All rights reserved Printed in the U S A
12. s a Windows service on Windows 2008 Server its user interface is not available The RSLinx Classic user interface is available only when RSLinx Classic software runs as an application Configuring EtherNet IP devices in RSLinx software and connecting to those devices in FactoryTalk EnergyMetrix software After configuring EtherNet IP network devices in RSLinx software it can be necessary to open RSWho and then browse to and select each device including Logix processor modules to enable FactoryTalk EnergyMetrix software to connect to the devices RT and ChartsPlus options on 64 bit operating systems The RT Real Time and ChartsPlus options do not run as rich client applications on a 64 bit operating system They run as ClickOnce applications NET Framework installation The NET Framework must be installed after IIS is installed and running If IIS is installed after these components then you must reinstall those components Creating PowerMonitor unit with unknown rack group address If a PowerMonitor unit on a remote 1 0 device is created with a rack group address that does not exist the RT device viewer can display bogus data DeviceNet communication to a PowerMonitor II meter FactoryTalk EnergyMetrix RT software does not support DeviceNet communication to the PowerMonitor II meter SQL server installed on another machine If FactoryTalk EnergyMetrix software is installed with a connection to an SQL server on
13. uary 2014 FactoryTalk EnergyMetrix Software Version 2 10 00 5 Known Anomaly FTEM Logger service to run under administrative account Description With FactoryTalk Live Data connection through RSLinx Enterprise both local and network scope can be used However you are required to set the FTEM Logger service to run under an administrative account Manual Data Entry limited to meters with maximum 35 tags Manually entering meter data is limited to meters with up to 35 tags Meters with more than 35 tags result in the system throwing an exception Power Quality Report does not support PowerMonitor 5000 Support for PowerMonitor 5000 in the Power Quality report is planned for a future version of FactoryTalk EnergyMetrix software Guest and User can delete waveforms and clear logs When logged in as a User or guest user can delete waveforms and clear logs through the RT viewer Power Quality Tab is displayed at the group level for non Power Quality power monitors When in the Meters Tab and a Group level is selected the Power Quality Summary tab is displayed in the Details pane for non Power Quality enabled power monitors RT Viewer does not show data in other tabs When you open the RT viewer and then quickly open another tab for example Energy Demand the value of the Energy Demand does not populate until the VI tab is clicked and the VI data is allowed to populate Once the VI data is available you can click on
14. well Automation or a system integrator contact the solution provider before attempting any software update Updating a customized installation without the necessary precautions can disable custom additions to the basic software Follow these steps to upgrade your RSEnergyMetrix installation to FactoryTalk EnergyMetrix software or to update your FactoryTalk EnergyMetrix software Installation from DVD or Downloaded DVD Image Follow these steps to install the software 1 Back up the FactoryTalk EnergyMetrix EMMA database 2 Obtain the login username and password of the SQL system administrator account used for the initial installation of FactoryTalk EnergyMetrix software 3 Download the upgrade file from the Rockwell Automation software updates page e Locate the downloaded file default is C Documents and Settings All Users Application Data RA FactoryTalk EnergyMetrix 2 10 00 FactoryTalk EnergyMetrix DVD e Or insert the installation DVD into the server s DVD drive 4 Browse to the FactoryTalk EnergyMetrix folder 5 Run the file setup exe Rockwell Automation Publication FIEM RNOO2A EN P February 2014 FactoryTalk EnergyMetrix Software Version 2 10 00 3 Enhancements with Version 2 10 00 6 On the dialog box that appears choose Remove all installed components TIP If an error message appears related to the installation script version exit the installation program Use the Windows Control Pa