Home

Installation - Cedgreentecheast.com

image

Contents

1. 7 2 Packaging the Webconnect Data Module for Shipping e Pack the Webconnect Data Module Use either the original packaging or other packaging suitable for the weight and size of the module see Section 9 Technical Data page 29 7 3 Disposing of the Webconnect Data Module Dispose of the Webconnect Data Module in accordance with the regulations for the disposal of electronic waste applicable at the site of installation or Return the Webconnect Data Module to SMA at your own expense labelled ZUR ENTSORGUNG FOR DISPOSAL see Section 11 Contact page 31 Installation Manual WebconnectDM IA US_en 10 27 8 Troubleshooting SMA America LLC 8 Troubleshooting Problem Cause and corrective measures The Webconnect Data Module There is no Speedwire connection cannot be accessed Corrective measures Check whether all network cable plugs are inserted and locked Check whether all inverters in the plant are in operation Check whether the plant router is switched on Check whether the ribbon cable plug of the Webconnect Data Module is correctly plugged into the center connector strip in the inverter The inverter does not recognize the Webconnect Data Module Corrective measures e Update the inverter firmware download the update file from www SMA Solar com Firewall or IP filter settings are not correct Corrective measures e Adjust firewall or IP filter settings see firewall or router manual The Web
2. Communication Interface for SMA Inverters SMA WEBCONNECT DATA MODULE Installation Manual 767 Z ti LI WebconnectDM IA US_en 10 98 4111010 Version 1 0 CCA GS SMA America LLC Legal Restrictions Copyright 2013 SMA America LLC All rights reserved No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photographic magnetic or otherwise without the prior written permission of SMA America LLC Neither SMA America LLC nor SMA Solar Technology Canada Inc makes representations express or implied with respect to this documentation or any of the equipment and or software it may describe including with no limitation any implied warranties of utility merchantability or fitness for any particular purpose All such warranties are expressly disclaimed Neither SMA America LLC nor its distributors or dealers nor SMA Solar Technology Canada Inc nor its distributors or dealers shall be liable for any indirect incidental or consequential damages under any circumstances The exclusion of implied warranties may not apply in all cases under some statutes and thus the above exclusion may not apply Specifications are subject to change without notice Every attempt has been made to make this document complete accurate and up to date Readers are cautioned however that SMA America LLC and SMA Solar Technology Cana
3. 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help The user is cautioned that changes or modifications not expressly approved by SMA America LLC could void the user s authority to operate this equipment IC Compliance This device complies with Industry of Canada l
4. 5 Connection 6 If a conduit is to be used proceed as follows Insert one rain or water proof sleeve diameter 1 in 25 4 mm into the enclosure opening and tighten from the inside using a counter nut Fit one conduit diameter 1 in 25 4 mm to the enclosure opening Lead one or two cables through the conduit into the inverter 7 If no conduit is to be used proceed as follows Attach the cable gland to the enclosure opening with the counter nut Unscrew the swivel nut of the cable gland on the inverter Press the seal out of the cable gland from the inside e Depending on the plant topology lead 1 or 2 network cables from the outside into the inverter through the loose swivel nut and the cable gland Installation Manual WebconnectDM IA US_en 10 21 5 Connection SMA America LLC Remove one of the filler plugs from the seal for each network cable gn Insert I or 2 network cables into the seal Route the network cable plugs into the inverter to the f network jacks 4 e Press the seal into the cable gland Make sure that any unused cable openings are sealed with filler plugs e Screw the swivel nut of the cable gland on lightly 8 Insert the network cables into the network jacks This can be done in any order 9 Fasten the swivel nut on the cable gland hand tight This will fix the network cables in place 10 Flip the display down and fasten it hand tight with the
5. SMA recommends the following cable types For outdoor use SMA COMCAB OUTxxx e For indoor use SMA COMCAB INxxx available in the following lengths xxx 328 ft 100 m 656 ft 200 m 1 640 ft 500 m 3 280 ft 1 000 m 5 3 Installing the Webconnect Data Module in the Inverter 1 A DANGER Danger to life due to electric shock when opening the inverter Lethal voltages are present in the conductive parts of the inverter e Disconnect the inverter from voltage sources on the AC and DC sides see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Open the inverter see inverter installation manual Release the screw of the display far enough to allow the display to be flipped up 4 Flip the display up until it clicks into place 18 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 5 Connection 5 Insert the Webconnect Data Module and slide the Tie ribbon cable upwards behind the display The key Pe at the top edge of the Webconnect Data Module AN N must fit into the hole in the plastic retainer in the inverter 6 Fasten the Webconnect Data Module hand tight with the hexagon socket screw 7 Flip the display down 8 Plug the ribbon cable plug onto the center connector strip 9 Attach one of the two supplied stickers with PIC and RID next to the type label of
6. deal with the dangers and risks associated with installation and operation of electrical devices and plants Knowledge of all applicable standards and directives e Knowledge of how an inverter works and is operated e Acquaintance with this document and all safety precautions 2 3 Safety Precautions A DANGER Danger to life due to electric shock Lethal voltages are present in the conductive parts of the inverter e Prior to performing any work on the inverter disconnect the inverter from all voltage sources on the AC and DC sides see inverter installation manual Observe the waiting time to allow the capacitors to discharge A CAUTION Burns from hot surfaces Some parts of the inverter enclosure may get hot during operation e During operation touch the inverter on the enclosure lid only NOTICE Damage to the inverter due to electrostatic discharge By touching electronic components you can damage or even destroy the inverter through electrostatic discharge ESD e Ground yourself before touching any inverter components Installation Manual WebconnectDM IA US_en 10 13 3 Scope of Delivery SMA America LLC 3 Scope of Delivery 3 1 Order Option Webconnect Data Module Pre installed in the Inverter Check the scope of delivery for completeness and any visible external damage Contact your specialty retailer if the delivery is incomplete or you find any damage A B C Figure 3 Components includ
7. display screw 11 Close inverter see inverter installation manual 12 Depending on the plant topology connect at least one inverter directly to the router 22 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 6 Commissioning 6 Commissioning 6 1 Commissioning the Plant Requirements L The Webconnect Data Module must be installed in the inverter see Section 5 3 Installing the Webconnect Data Module in the Inverter page 18 L The Webconnect Data Module must be connected see Section 5 4 Connecting the Webconnect Data Module page 20 1 Depending on the plant topology at least one inverter must be connected to the router LD DHCP must be enabled in the router Commission all inverters with installed Webconnect Data Module see inverter operating manual 6 2 Plant Management with Sunny Explorer 6 2 1 Functions and Parameter Settings in Sunny Explorer The following functions for plant management in Sunny Explorer are available Overview of the plant status Graphic display of key plant data device data and energy values Parameterization of individual devices or an entire device class Simple diagnostics due to display of faults and events Data export of inverter energy values and events in CSV format Device updates You can change the following parameters in Sunny Explorer Device name of the inverter Automatic IP configuration On Off DNS IP gateway IP IP address subnet mask Webconnect
8. the inverter on the inverter enclosure Installation Manual WebconnectDM IA US_en 10 19 5 Connection SMA America LLC 5 4 Connecting the Webconnect Data Module Requirements O O All electrical installations must be carried out according to all electrical standards applicable on site and the National Electrical Code NE ANSI NFPA 70 Installations in Canada must be carried out in accordance with the applicable Canadian standards Supplementary material not included in the scope of delivery O O 20 Cable for connection of the Webconnect Data Module see Section 5 2 Cabling of the Local Speedwire Network page 18 If cables are routed in a conduit 1 rain or water proof sleeve diameter 1 in 25 4 mm 1 conduit diameter 1 in 25 4 mm A DANGER Danger to life due to electric shock when opening the inverter Lethal voltages are present in the conductive parts of the inverter e Disconnect the inverter from voltage sources on the AC and DC sides see the inverter installation manual Observe the waiting time to allow the capacitors to discharge Open the inverter see inverter installation manual Release the screw of the display far enough to allow the display to be flipped up Flip the display up until it clicks into place Push the pre mounted filler plug out of the second hole from the left in the inverter enclosure WebconnectDM IA US_en 10 Installation Manual SMA America LLC
9. A America LLC 2 Safety 2 Safety 2 1 Intended Use The Webconnect Data Module is a Webconnect communication interface for inverters which is based on the SMA Speedwire technology Speedwire is a wire based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimized 10 100 Mbit data transmission between Speedwire devices in PV plants The Webconnect function enables data transmission between the Internet portal Sunny Portal and the inverters This data transmission takes place via a router with Internet access A PC with the software Sunny Explorer is also connected to the router As of software version 1 04 Sunny Explorer is available free of charge at www SMA Solar com The Webconnect Data Module performs the following tasks e Set up of a Speedwire network e Data exchange with the Internet portal Sunny Portal and Sunny Explorer via a router A plant in Sunny Portal can consist of a maximum of four inverters with installed Webconnect Data Module The Speedwire network can be set up with the following optional topologies e Linear topology e Star topology Sunny Portal B B a oy Ma Si Rouier Internet Local Speedwire Network Sunny Explorer Figure 1 PV plant with a Speedwire network in linear topology example Installation Manual WebconnectDM IA US_en 10 11 2 Safety SMA America LLC Sunny Boy Sunny
10. Boy Sunny Portal Internet Router Figure 2 PV plant with a Speedwire network in star topology example The Webconnect Data Module is provided as a retrofit kit or is pre installed in the inverter The Webconnect Data Module can only be installed in the following inverters as of firmware version 2 51 e Sunny Boy 3000TL US 22 AOOOTL US 22 5000TLUS 22 e Sunny Tripower 1 2000TL US 10 15000TL US 10 20000TL US 10 24000TLUS 10 For information on firmware updates refer to the Technical Description Firmware Update with SD Card at www SMA Solar com For safety reasons it is forbidden to modify the product or install components that are not explicitly recommended for this product or distributed by SMA The enclosed documentation is an integral part of this product e Read and adhere to the documentation e Keep the documentation in a convenient place for future reference Only use the additional Webconnect Data Module in accordance with the specifications provided in the enclosed documentation Any other use can result in personal injury or material damage 12 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 2 Safety 2 2 Skills of Qualified Persons The tasks described in this document must be performed by qualified persons only Qualified persons must have the following skills e Training in the installation and commissioning of electrical devices and plants Knowledge of how to
11. D must be available for the Webconnect Data Module Your computer must have an Internet connection A JavaScript enabled browser must be installed Maximum permissible number of devices for a plant in Sunny Portal In Sunny Portal you can manage several plants A maximum of four interconnected inverters with installed Webconnect Data Module per plant is permitted Starting the Plant Setup Assistant in Sunny Portal The Plant Setup Assistant is a step by step guide of the processes required for user registration and the registration of your plant in Sunny Portal l Go to www SunnyPortal com Register see user manual for Webconnect plants in Sunny Portal The Plant Setup Assistant opens Select Next The User Registration page opens Plant with Webconnect Data Module cannot be combined with other plants Even if you already have a plant registered in Sunny Portal with another communication device e g Sunny WebBox you will still need to create a separate plant with Webconnect Data Module It is not possible to combine the Webconnect Data Module and other communication devices within one plant in Sunny Portal Sunny Portal treats the existing plant and the new plant with Webconnect Data Module as separate plants An inverter with integrated Webconnect function can be assigned to max 1 plant e If applicable delete any existing WebBox plant in Sunny Portal When doing so ensure that the entire plant data is irrevocably era
12. and operation of the product you must carefully read and follow all instructions cautions and warnings in this manual Warnings in this document A warning describes a hazard to equipment or personnel It calls attention to a procedure or practice which if not correctly performed or adhered to could result in damage to or destruction of part or all of the SMA equipment and or other equipment connected to the SMA equipment or personal injury Symbol A DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury A WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury A CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE is used to address practices not related to personal injury 4 WebconnectDM IA US_en 10 Installation Manual SMA America LLC Important Safety Instructions General Warnings A WARNING General Warnings All electrical installations must be made in accordance with the local and National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 This document does not and is not intended to replace any local state provincial federal or national laws regulations or codes applicable to the installation and use of the product including without limitation applicable electrical safety codes All installations mus
13. connect Data Module does not have a valid IP address Corrective measures e Double tap the computer to check whether a valid IP address has been assigned If N A appears on the display no IP address has been assigned to the Webconnect Data Module Check whether DHCP is activated in the router or assign a manual IP address to the Webconnect Data Module 28 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 9 Technical Data 9 Technical Data General Data Voltage supply via inverter Mechanical Data Width x height x depth 2 iginx3 Mo in x 1 in 73 mm x 88 mm x 34 mm Communication ee Maximum cable length 328 ft 100 m Maximum data volume per Webconnect Data 550 MB Module per month Additional data volume per hour when using the 600 kB Sunny Portal Live interface Connections Type of plug RJ45 2 Number of RJ45 terminals Ambient Conditions during Operation Ambient temperature 40 F 185 F Maximum height above sea level MSL Ambient Conditions for Storage Transport Ambient temperature AO Fa HEST 40 C 85 C Relative humidity non condensing 10 100 Maximum height above sea level MSL 9 842 ft 3 000 m Installation Manual WebconnectDM IA US_en 10 29 10 Compliance Information SMA America LLC 10 Compliance Information FCC Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions
14. da Inc reserve the right to make changes without notice and shall not be responsible for any damages including indirect incidental or consequential damages caused by reliance on the material presented including but not limited to omissions typographical errors arithmetical errors or listing errors in the content material All trademarks are recognized even if these are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by SMA America LLC and SMA Solar Technology Canada Inc is under license SMA America LLC 3801 N Havana Street Denver CO 80239 U S A SMA Solar Technology Canada Inc 2425 Matheson Blvd E 8th Floor Mississauga ON LAW 5K5 Canada Installation Manual WebconnectDM IA US_en 10 3 Important Safety Instructions SMA America LLC IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for the following product e SMA Webconnect Data Module This manual must be followed during installation and maintenance The product is designed and tested according to international safety requirements but as with all electrical and electronic equipment certain precautions must be observed when installing and or operating the product To reduce the risk of personal injury and to ensure the safe installation
15. ed in delivery Webconnect Data Module pre installed in the inverter item Quantity Designation Installation manual B 1 Cable gland Sticker with PIC and RID for registration in Sunny Portal 3 2 Order Option Webconnect Data Module as Retrofit Kit Check the scope of delivery for completeness and any visible external damage Contact your specialty retailer if the delivery is incomplete or you find any damage B C D Figure 4 Components included in delivery Webconnect Data Module as retrofit kit Hem Quantity Webconnect Data Module B 1 Installation manual Cable gland o ie Sticker with PIC and RID for registration in Sunny Portal 14 WebconnectDM IA US_en 10 Installation Manual SMA America LLC A Product Description 4 Product Description 4 1 Webconnect Data Module The Webconnect Data Module is a Webconnect communication interface for inverters which is based on the SMA Speedwire technology Speedwire is a wire based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimized 10 100 Mbit data transmission between Speedwire devices in PV plants The Webconnect function enables data transmission between the Internet portal Sunny Portal and the inverters This data transmission takes place via a router with Internet access A PC with the software Sunny Explorer is also connected to the router As of software version 1 04 Sunny Explo
16. function On Off Installation Manual WebconnectDM IA US_en 10 23 6 Commissioning SMA America LLC 6 2 2 Connection to Sunny Explorer Requirement L The plant must be commissioned see Section 6 1 Commissioning the Plant page 23 1 Connectthe computerto the plant router with a network cable 2 Start Sunny Explorer and create plant see Sunny Explorer user manual 6 3 Monitoring the Plant in Sunny Portal Sunny Portal is an Internet portal for the monitoring of plants as well as the visualization and presentation of plant data The following functions for monitoring your plant in Sunny Portal are available e Sending of status reports via e mail to computer or cell phone e Summary of key plant data in a plant overview and a plant profile e Overview of the energy and power curves of your plant e Report of plant yields in form of daily or monthly reports or as an annual summary Communication monitoring between Sunny Portal and a maximum of four inverters with Webconnect function per plant e Plant monitoring based on inverter comparison provided that there are at least two inverters in the plant e Overview of device properties parameters and messages 24 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 6 Commissioning 6 3 1 Registering a Plant in Sunny Portal Requirements O i The plant must be commissioned see Section 6 1 Commissioning the Plant page 23 PIC and RI
17. hich if not avoided can result in death or serious injury A CAUTION Indicates a hazardous situation which if not avoided can result in minor or moderate injury NOTICE Indicates a situation which if not avoided could result in property damage Information that is important for a specific topic or goal but is not a wii relevant O Indicates a requirement for meeting a I Indicates a requirement for meeting a specific goal goal x A problem that could occur Typographies Typography Display texts e The value can be found in the Energy field Elements on a user interface Connections Select Settings e Enter value 10 in the Minutes field Connects several elements to Select Settings gt Date be selected Button Key Button or key to be selected or Select Next pressed Installation Manual WebconnectDM IA US_en 10 9 Elements to be selected Elements to be entered 1 Information on this Document SMA America LLC Nomenclature Abbreviations DHCP Dynamic Host Configuration Protocol Protocol for the dynamic assignment of IP configurations ESD Electosttie Discharge ee Product Identification Code Identification key for registration in Sunny Portal Registration Identifier Registration key for registration in Sunny Portal Figures In this document the illustrations of the inverter type SB x000 TL US 22 may deviate slightly 10 WebconnectDM IA US_en 10 Installation Manual SM
18. icence exempt RSS standard s Operation is subject to the following two conditions e This device may not cause interference and This device must accept any interference including interferences that may cause undesired operation of the device 30 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 11 Contact 11 Contact If you have technical problems concerning our products contact the SMA Service Line We require the following information in order to provide you with the necessary assistance e Type serial number and firmware version of the inverter e Type serial number and firmware version of the Webconnect Data Module e PIC and RID numbers of the Webconnect Data Module e Number of connected inverters with integrated Webconnect function America SMA America LLC Rocklin CA 1 877 MY SMATech 1 877 697 6283 1 916 625 0870 Canada SMA Canada Inc Toronto 1 877 MY SMATech 1 877 697 6283 toll free for USA Canada and Puerto Rico international toll free for Canada Installation Manual WebconnectDM IA US_en 10 31 SMA Solar Technology SMA America LLC www SMA America com
19. nag rs Ria aa 6 1 Commissioning the Plant i 6 2 Plant Management with Sunny Explorer 0000000 6 2 1 Functions and Parameter Settings in Sunny Explorer 6 2 2 Connection to Sunny Explorer 6 3 Monitoring the Plant in Sunny Portal 6 3 1 Registering a Plant in Sunny Portal ii Installation Manual WebconnectDM IA US_en 10 Table of Contents SMA America LLC 7 DECOMMISSIONING 26 7 1 Disassembling the Webconnect Data Module 26 7 2 Packaging the Webconnect Data Module for Shipping 27 7 3 Disposing of the Webconnect Data Module 27 8 Troubleshooting 28 9 Technical Data ee 29 10 Compliance Information 30 PI COniacdt a italien 31 8 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 1 Information on this Document 1 Information on this Document Validity This document is valid for device type SWDM US 10 with firmware version 1 00 00 R or higher Target Group This document is intended for qualified persons Only qualified persons with the appropriate skills are allowed to perform the tasks described in this document see Section 2 2 Skills of Qualified Persons page 13 Symbols Symbol DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury A WARNING Indicates a hazardous situation w
20. nnection of the network cables with the inverter enclosure The cable gland also protects the inverter from dust and moisture penetration Figure 6 Product description Cable gland Designation Filler plug Swivel nut Counter nut 16 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 5 Connection 5 Connection 5 1 Device Overview Designation Flipped up display with screw Cable route to the network jacks Opening in the inverter enclosure with filler plug Mounting position of the Webconnect Data Module in the inverter Installation Manual WebconnectDM IA US_en 10 17 5 Connection SMA America LLC 5 2 Cabling of the Local Speedwire Network The cable length and quality have an effect on the signal strength in the Soeedwire network Note the following information regarding network cabling Interference of network data transmission due to AC cables When AC cables are in operation they generate an electromagnetic field which may induce leading or lagging interference in network cables during data transmission e Lay the network cables using suitable fastening material and with a minimum clearance of 2 in 50 mm to AC cables Cable requirements 1 Maximum cable length 328 ft 100 m O Cross section min 2 x 2 x 0 22 mm or min 2 x 2 AWG 24 Q Cable type 100BaseTx CATS with shielding S UTP F UTP or higher 1 UV resistant for outdoor use 1 Type of plug RJ45
21. rer is available free of charge at www SMA Solar com The Webconnect Data Module performs the following tasks e Set up of a Speedwire network e Data exchange with the Internet portal Sunny Portal and Sunny Explorer via a router The Webconnect Data Module is provided as a retrofit kit or is pre installed in the inverter Figure 5 Components of the Webconnect Data Module tom Designation CC fe Network jock E ee on C Installation Manual WebconnectDM IA US_en 10 15 A Product Description SMA America LLC Sticker with PIC and RID To activate the data module in the Sunny Portal you will need the PIC and RID numbers printed on the supplied sticker One of the two stickers should be affixed next to the type label on the inverter The second sticker is for the customer or plant operator 4 2 Type Label The type label clearly identifies the Webconnect Data Module The type label is located in the top right hand corner at the front of the Webconnect Data Module You can read the following data from the type label e Product designation e Device type and hardware version e Serial number e MAC Address e PIC and RID The information on the type label is required for safe use of the Webconnect Data Module and for reference if customer support from the SMA Service Line is needed The type label must be permanently affixed to the Webconnect Data Module 4 3 Cable Gland The cable gland provides a sturdy tightly sealed co
22. sed e Create a new plant with Webconnect Data Module Installation Manual WebconnectDM IA US_en 10 25 7 Decommissioning SMA America LLC 7 Decommissioning 7 1 Disassembling the Webconnect Data Module 1 A DANGER Danger to life due to electric shock when opening the inverter Lethal voltages are present in the conductive parts of the inverter e Disconnect the inverter from voltage sources on the AC and DC sides see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Open the inverter see inverter installation manual Press the left and right lock catches outwards and remove the ribbon cable plug from the center connector strip of the inverter Release the screw of the display far enough to allow the display to be flipped up Flip the display up until it clicks into place Unscrew the swivel nut of the cable gland Remove the network cables from the Webconnect Data Module o Sa SS Unscrew the counter nut of the cable gland 9 Pull the cable gland and network cables out of the inverter 10 Release the screw of the Webconnect Data Module and remove it 11 Flip the display down and fasten the display screw hand tight 12 Close the enclosure opening with an appropriate filler plug 13 Close inverter see inverter installation manual M The Webconnect Data Module is now disassembled 26 WebconnectDM IA US_en 10 Installation Manual SMA America LLC 7 Decommissioning
23. t conform with the laws regulations codes and standards applicable in the jurisdiction of installation SMA assumes no responsibility for the compliance or noncompliance with such laws or codes in connection with the installation of the product The product contains no user serviceable parts For all repair and maintenance always return the unit to an authorized SMA Service Center Before installing or using the product read all of the instructions cautions and warnings in this manual Wiring of the product must be made by qualified personnel only Installation Manual WebconnectDM IA US_en 10 5 General Warnings SMA America LLC 6 WebconnectDM IA US_en 10 Installation Manual SMA America LLC Table of Contents Table of Contents Information on this Document 2 af Dali ne 2 2 Skills of Qualified Persons i 2 9 Solety PreCGUilONs lieto a 3 Scope of Delivery 3 1 Order Option Webconnect Data Module Pre installed in the WY OT CD sb 0 h da eee ri 3 2 Order Option Webconnect Data Module as Retrofit Kit 4 Product Description 4 1 Webconnect Data Module 2 Te S CONNECHON se ee a S DENG NEMNE OE 5 2 Cabling of the Local Speedwire Network ii 5 3 Installing the Webconnect Data Module in the Inverter 5 4 Connecting the Webconnect Data Module 6 Comniissoni