1. Model CP622 CP8201 CP6201 CP4201 CP2201 GP8201 Weighing capacity g 620 8 200 6 200 4 200 2 200 Readability scale interval g 0 01 0 1 0 1 0 1 0 1 Tare range subtractive g 620 8 200 6 200 4 200 2 200 Repeatability std deviation lt g 0 01 0 1 0 1 0 1 0 1 Linearity lt tg 0 02 0 2 0 2 0 2 0 2 Response time average s lt 1 Operating temperature range C 10 30 C 50 F to 86 F Allowable ambient operating temperature 7 0 40 C 32 F to 104 F Sensitivity drift lt K 5 10 5 10 5 1078 10 1078 10 1078 within 10 30 C External calibration weight g 500 F2 5 000 F1 5 000 F2 2 000 F2 2 000 F2 of at least accuracy class Net weight approx kg 2 8 3 6 3 6 3 6 3 6 Pan size mm 154 190x204 190x204 190x204 190x204 Pan surface cm 227 369 369 369 369 Dimensions WxDxH mm 213x342x90 AC power source Vw AC adapter 230 V or 115 V 15 20 power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO5Z rechargeable battery pack h 40 Selectable weight units Grams kilograms carats pounds ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface RS 232 V24 V28 Format 7 bit ASCII 1 start
2. Model CP2P CP2P F Weighing capacity mg 500 1000 2000 500 1000 2000 Max loading capacity mg approx 2000 approx 2000 Readability mg 0 001 0 002 0 005 0 001 0 002 0 005 Tare range subtractive mg approx 2000 approx 2000 Repeatability std deviation lt tmg 0 001 0 002 0 003 0 002 0 003 0 004 Linearity stmg 0 002 0 004 0 005 0 002 0 004 0 005 Response average 10 10 Operating temperature range C 15 30 C 59 F to 86 F Allowable ambient operating temperature C 5 40 C 41 F to 104 F Sensitivity drift within 15 30 C lt K 5 10 External calibration weight g 2 E2 2 E2 of at least accuracy class Weighing pan diameter mm 20 125 or 20 Dimensions Wx Dx H mm 213x342x151 213x342x115 Weighing chamber WxDxH mm 54x49 5x55 5 Height 12 Net weight approx kg 4 35 5 0 AC power source Vw AC adapter 230 V or 115 V 15 20 Power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO8Z rechargeable battery pack h 22 22 Selectable weight units Grams carats pounds ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface Format Parity Transmission rates Handshake mode RS 232 V24 V28 7 bit ASCII 1 star
3. Function Keys Begin determination of piece weight Application program initialized with predefined reference sample quantity End application program clear initialization data Changing the reference sample quantity Press and hold CFD 2 sec gt Current reference sample quantity is displayed O Press CFD briefly to change the value press repeatedly until the desired reference sample quantity is displayed Quantities to choose from 1 2 5 10 20 50 100 Store setting in long term memory Press and hold CF 39 Reference Sample Updating Automatic reference sample updating optimizes the counting accuracy You can activate or de activate this function in the menu Automatic reference sample updating is performed when the criterion for the stability parameter selected in the menu has been met the current piece count is less than twice the original piece count the current piece count is less than 100 x the initialization value the internally calculated piece count such as 17 24 pes differs by less than 0 3 pes from the whole number 17 pes in this example The abbreviation oft for optimizing is displayed briefly with the new reference sample quantity 40 Reference Weighing Counting with two balances scales Purpose Use of a reference balance scale affords higher precision in counting large amounts of parts The CP balance is used to deter mine the referen
4. s Space H Overload C Calibration adjustment Ls Underload Error Codes Position 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 Ets spi CR LF x Space BR Error code number 56 Data output example 123 56 g Position 1 2 3 4 5 6 8 9 O 1 2 3 4 1 2 5 6 g CR LF 1 2 3 5 6 g CR LF 1 2 3 5 6 g CR LF Position 1 Plus or minus sign or space Position 2 Space Positions 3 10 Weight with a decimal point leading zeros space Position 11 Space Positions 12 14 Unit symbol or space Position 15 Carriage return Position 16 Line feed Data Output with an ID Code 22 Characters When data is output with an ID code the ID code consisting of 6 characters precedes the data with the 16 character format These 6 characters identify the following value 1 1 DDD DOD DOD D U UU CR LF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 l 1D code character U Unit symbol Space CR Carriage return D Digit or letter LF Line feed Example 1 2 3 4 5 6 7 8 9 O 1 2 4 5 6 7 8 9 O N 1 2 5 6 g CR LF N 1 2 3 5 6 g CR LF N 1 2 3 5 6 g CR LF depends on balance scale type e g not all units and characters are available on balances verified for use in legal metrology 57 Special Codes 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Sta oe 8 8 RR
5. 53 On for FB FC LA LP models _8 84 On for isi terminals o Factory setting Reference sample quantity Reference weight Calculated quantity 41 Example Counting pieces of equal weight Settings Menu Counting program menu code 14 Print application parameters On all parameters menu code 7 i Line format for printout 22 characters menu code 7 2 Step Key or instruction Display Printout 1 Turn on the balance scale Ce if necessary 2 Place empty container ec 6 g on the balance scale 3 Tare the balance scale UU g 4 Add reference sample quantity to container in this example 10 pcs 5 Initialize the balance scale CFD rEF id briefly Z iHg iD pes nRef 10 pcs wRef 2 14 g 6 Add desired number 500 pes of pieces 7 Print piece count if desired CQ gt C gt ant 500 pcs 8 Display weight IW iD g 9 Display piece count 10 Unload the balance scale _ Gii pes 11 Repeat as necessary starting from step 6 12 Delete reference ou g sample quantity 42 ple q ty Weighing in Percent Menu code 2 5 Display symbol Purpose This application program allows you to obtain weight readouts in percent which are in proportion to a reference weight Features The minimum load is equal to one digit defined according to the resolution of the active weight unit Press and hold the CFD key 2 seconds to set the reference percenta
6. 64 output is blocked factory settings or Contact your local Sartorius Service Center Display Cause Solution Err 235 on the CP225D Connecting cable not connected correctly Connection to junction on a different balance scale Connect the cable correctly Connect the equipment correctly The weight readout changes constantly Unstable ambient conditions A foreign object is caught between the load plate and the balance scale frame Set up the balance scale in another area Remove the foreign object The weight readout is obviously wrong The balance scale has not been calibrated adjusted The balance scale was not zeroed before weighing Calibrate adjust the balance scale Tare or zero the balance scale before weighing If any other errors occur contact your local Sartorius Service Center Contact information Please point your Internet browser to www sartorius com Preparing CP2P Models for Transport Model CP2P Remove the weighing pan Remove the interior draft shield from the chamber Use your fingers to raise the draft shield carefully until it is free Place these parts in the accessory kit Fasten the chamber doors by placing a rubber band around the door handles Model CP2P F until it is free Remove the filter pan lid from the chamber Use forceps to remove the filter weighing pan care fully from the chamber Remove the interior dr
7. 84 Declaration of Conformity Weighing Instruments for Use in Legal Metrology Council Directive 90 384 EEC Non automatic weighing instruments This Directive regulates the determination of mass in legal metrology For the respective Declaration of Type Conformity for weighing instruments that have been verified by Sartorius for use as legal measuring instruments and that have an EC Type Approval Certificate see the page after next This Directive also regulates the performance of the EC verification by the manufacturer provided that an EC Type Approval Certi ficate has been issued and the manufacturer has been accredited by an officer of a Noti fied Body registered at the Commission of the European Community for performing such verification Sartorius complies with EC Directive No 90 384 EEC for non automatic weigh ing instruments which has been in effect since January 1 1993 within the Single European Market as well as the accredita tion of the Quality Management System of Sartorius AG by Lower Saxony s Regional Administrative Department of Legal Metrolo gy Nieders chsisches Landesverwaltungsamt Eichwesen from February 15 1993 For additional information on the C mark on Sartorius equipment see Sartorius Publication No W 0052 e93081 New Installation Service Initial verification is covered in our New Installation service package In addition to initial verification thi
8. 32 Sartorius Operating Instructions Sartorius Competence CP Series Sartorius GemP CP GC and GP Models Electronic Micro and Analytical Precision Balances and Precious Metal Scales UA UMD TA AAA A 98648 009 91 15 15 16 18 20 24 24 25 26 31 34 35 39 40 43 46 49 Contents Contents Intended Use Warnings and Safety Precautions Getting Started Operating the Balance Scale Overview of Display and Operating Elements Basic Weighing Function Below Balance Under Scale Weighing Calibration Adjustment Configuring the Balance Scale Printing the Settings Setting the Parameters Menu Codes Parameter Settings Overview Setting IDs Time Date and Display Brightness Application Programs Net Total Formulation Counting Reference Weighing Weighing in Percent Animal Weighing Averaging Toggle between Weight Units 50 53 55 59 62 63 64 65 66 68 69 69 82 85 89 Generating a Printout 1SO GLP compliant Printout Data Interface Data Input Format Pin Assignment Chart Cabling Diagram Error Codes Preparing CP2P Models for Transport Care and Maintenance Instructions for Recycling Overview Specifications Accessories Options Declaration of Conformity Plates and Markings Intended Use The models of the CP GP and GC Series are weighing instruments of special and high accuracy designed for the measure ment of mass covering a range f
9. order number 6971966 and replaceable power cable 6900900 Europe 6900901 US CDN 6971945 UK 6900905 AUS 6900902 ZA Balances Scales with a Weighing Capacity of over 10 kg Insert the right angle plug into the jack and tighten the screw Safety Precautions The AC adapter rated to Class 1 can be plugged into any wall outlet using a protective bonding conductor grounding without any additional safety precautions The ground or earth terminal is connected to the balance scale housing which can be additionally grounded if required The data interface is also electrically connected to the balance scale housing ground Information on Radio Frequency Interference This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to Sub part J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to cor rect the interference 30 Connecting Electronic Peripheral Devices Make absolutely sure to unplug the balan
10. lt 1 mg meet IP32 requirements AC adapters meet IP20 requirements Protect the AC adapter and the weighing instrument from contact with liquids When cleaning your balance scale make sure that no liquid enters the balance scale housing use only a slightly moistened cloth to clean the balance scale Do not open the balance scale housing If the seal is broken this will result in forfeiture of all claims under the manufacturer s warranty If you have any problems with your balance scale Contact your local Sartorius office dealer or service center Getting Started Storage and Shipping Conditions Do not expose the balance scale to extreme temperatures blows shocks vibration or moisture Unpacking the Equipment After unpacking the balance scale check it immediately for any visible damage as a result of rough handling during shipment O If you see any sign of damage proceed as directed in the section on Safety Inspection in the chapter entitled Care and Maintenance It is a good idea to save the box and all parts of the packaging until you have successfully installed your balance scale Only the original packaging provides the best protection for shipment Before packing your balance scale unplug all connected cables to prevent damage Equipment Supplied The equipment supplied includes the components listed below CP2P CP2P F Balance Scale with display and control unit Kit
11. mm 213x342x270 AC power source Ve AC adapter 230 V or 115 V 15 20 Power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO8Z rechargeable battery pack h 22 22 22 27 Selectable weight units Grams carats pounds ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface Format Parity Transmission rates Handshake mode RS 232 V24 V28 7 bit ASCII 1 start bit 1 or 2 stop bits Mark odd even or space 150 to 19 200 baud Software or hardware For readability 0 005 ct select menu code 1 8 1 or 3 2 1 see Configuring the Balance Scale 2 ZZ Three sided weighing pan Diameter of inner circle Z The cross hatched section can be fully utilized 71 Competence Series CP Series Model CP423S CP323S CP323P CP153 Weighing capacity g 420 320 80 160 320 150 Readability 0 001 0 001 0 001 0 002 0 001 0 005 Tare range subtractive g 420 320 320 150 Repeatability std deviation lt g 0 001 0 001 0 001 0 001 0 001 0 003 Linearity stg 0 002 0 002 0 002 0 002 0 001 0 005 Response time average s lt 1 5 Operating temperature range C 10 30 C 50 F to 86 F
12. mm 213x342x340 Electronics box WxDxH mm 134x51x155 AC power source Vw AC adapter STNG6 230 VAC or 115 VAC Power requirements 15 20 protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 average 8 Approx hours of operation with the YRBO5Z rechargeable battery pack h 20 22 22 22 22 Selectable weight units Grams milligrams carats Grams carats Built in interface RS 232C S V24 V28 7 bit parity even mark odd space transmission rates 150 19 200 baud 1 or 2 stop bits software hardware handshake 1 CD Council Directive 90 384 EEC on non automatic weighing instruments applicable to the European Economic Area 2 IZ Three sided weighing pan Diameter of inner circle La The cross hatched section can be fully utilized 76 Gem Series Model GC1603S 0CE GC803S 0CE Type BC BL 100 BC BL 100 Accuracy class Maximum capacity Max ct 1 600 800 Readability ct 0 001 0 001 Tare range subtractive ct lt 100 of the maximum capacity Verification scale interval e mct 10 10 Minimum capacity Min ct 0 1 0 1 Stabilization time average s lt 2 Range of use ct 0 1 1 600 0 1 800 according to CD Allowable ambient operating temperature C 15 25 59 F to 77 F External calibration weight g 200 100 E2 of at least accuracy class 100 E2 Net weight approx kg
13. 02 420 0 01 320 0 02 320 0 02 150 Allowable ambient operating temperature eC 10 30 50 F to 86 F Net weight approx kg 4 6 Pan size inner diameter mm 110 Pan area cm 120 Weighing chamber height from pan to sliding cover mm 50 Dimensions WxDxH mm 213x342x153 AC power source Vw AC adapter STNG6 230 VAC or 115 VAC Power requirements 15 20 protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 average 8 Approx hours of operation with the YRBO5Z rechargeable battery pack h 27 Selectable weight units Grams carats Built in interface RS 232C S V24 V28 7 bit parity even mark odd space transmission rates 150 19 200 baud 1 or 2 stop bits software hardware handshake 1 CD Council Directive 90 384 EEC on non automatic weighing instruments applicable to the European Economic Area ZZ Three sided weighing pan Diameter of inner circle Le The cross hatched section can be fully utilized 78 Competence CP and Gem Series Model CP4202S OCE CP3202S OCE CP3202P OCE CP2202S 0CE CP4202S ACE CP3202S ACE GP3202 0CE Type BD BL 200 BD BL 200 BD BL 200 BD BL 200 Accuracy class Maximum capacity Max g 4 200 3 200 800 1 600 2 200 3 200 Scale interval d g 0 01 0 01 0 01 0 02 0 01 0 05 Tare range subtractive g lt 100 of the maximu
14. 5 16 000 5 12 000 150 34 000 Allowable ambient operating temperature C 10 30 50 F to 86 F Net weight approx kg 16 Pan size mm 300x400 Dimensions WxDxH mm 313x532x 120 AC power source V AC adapter STNG6 2 230 VAC or 115 VAC Power requirements 15 20 protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 average 8 Approx hours of operation with the YRBO6Z rechargeable battery pack h 22 Selectable weight units Grams kilograms carats Built in interface RS 232C S V24 V28 7 bit parity even mark odd space transmission rates 150 19 200 baud 1 or 2 stop bits software hardware handshake 1 CD Council Directive 90 384 EEC on non automatic weighing instruments applicable to the European Economic Area 81 Accessories Options Product Order No Data printer YDPO3 OCE with date time statistics evaluation and transaction counter functions and LCD Remote display reflective data interface required YRDO2Z Remote display transmissive for overhead projectors data interface required YRD13Z External rechargeable battery pack for models with weighing capacities under 10 kg YRBO5Z for models with weighing capacities over 10 kg YRBO6Z gt with battery level indicator LED can be recharged using the AC adapter time it takes to charge the discharged battery pa
15. Allowable ambient operating temperature iC 0 40 C 32 F to 104 F Sensitivity drift within 10 30 C lt K 2 107 External calibration weight g 200 F1 200 F1 100 F1 100 F1 of at least accuracy class Net weight approx kg 3 7 Pan size inner diameter mm 110 Pan surface cm 120 Weighing chamber height from pan to cover mm 50 Dimensions WxDxH mm 213x342x153 AC power source Vw AC adapter 230 V or 115 V 15 20 Power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO8Z rechargeable battery pack h 27 Selectable weight units Grams carats pounds ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface Format Parity Transmission rates Handshake mode 2 72 RS 232 V24 V28 7 bit ASCII 1 start bit 1 or 2 stop bits Mark odd even or space 150 to 19 200 baud Software or hardware AA Three sided weighing pan Diameter of inner circle Z The cross hatched section can be fully utilized Competence CP Series and Gem Series Model CP4202S CP3202S CP3202P CP2202S GP3202 Weighing capacity g 4 200 3 200 800 1 600 2 200 3 200 Readability g 0 01 0 01
16. C dependent on or independent of stability 50 You can have the following values output automatically when using the application programs if menu code i cis configured printout with data ID codes Net total Component or total weight Counting Reference sample quantity nRef Reference weight for one piece average piece weight wRef Weighing in percent Reference percentage pRef Reference weight Wxx Animal weighing averaging Number of subweighing operations mDef Calculated average x Net Factory Settings Print manual automatic Individual printout dependent on stability Manual at stability menu code 6 i 2 Line format Up to 6 characters at the beginning of each line to identify the weight or calculated value Print net tare or gross value reference sample quantity or average piece weight with ID menu code 7 2 2 Print application parameters Printout of one or more initialization val ues for the active application program On menu code 7 2 1SO GLP compliant printout No 1SO GLP compliant printout menu code amp i0 Auto print Automatic printout of weight values No default setting see print manual automatic menu code amp 2 Automatic printout after each display cycle menu code 6 3 1 cannot be interrupted by pressing CQ C gt menu code 6 2 2 Set the following parameters See Configuring the Balance Scale 51 Printout without Da
17. Mess und Eichwesen verification act vom dated 23 M rz 1992 BGBI S 711 in Verbindung mit Richtlinie in connection with council directive 90 384 EWG ge ndert durch amen ded by 93 68 EWG Nichtselbsttatige elektromechanische Waage Nonautomatic electromechanical weighing instrument BC BL 100 BD BL 200 BF BL 500 amp Max 50 320g e 1 5mg n lt 320000 aD Max 1 34000 g e 0 01 59 n lt 52000 dD Max 100 34000 g e 1 50g n lt 10000 Option Mehrteilungswaage multi interval instrument D01 09 019 1 Revision 2011 09 03 1 14 02000687 0102 Braunschweig 2002 05 28 Siegel Seal ist Hinweise und eine Recntsver Bedungen und Auflagen sind in der Anlage enthalten die Bestandteil der EG Bauartzulassung sbelehrung befinden sich auf der ersten Seite der Anlage The principal characteristics approval conditions and special conditions if any are set out in the Annex which forms an integral part of the EC type approval certificate For notes and information on legal remedies see first page of the Annex Plates and Markings Types BC BL 100 BD BL 200 locked Sen I unlocked locked Menu access switch External electronics unlocked alternative for type BC BL 100 Type BF BL 500 View of unlocked Menu access switch K Descriptive plate with CE mark of conformity M Mark for EC verification green metrolo
18. average s lt 1 Range of use according to CD g 0 5 620 5 8 200 5 6 200 5 2 200 Allowable ambient operating temperature C 10 30 50 F to 86 F Net weight approx kg 4 7 Pan size mm 190x204 Pan area cm 369 Dimensions WxDxH mm 213x342x90 AC power source Vw AC adapter STNG6 230 VAC or 115 VAC Power requirements 15 20 protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 average 8 Approx hours of operation with the YRBO5Z rechargeable battery pack h 40 Selectable weight units Grams kilograms carats Built in interface CD Council Directive 90 384 EEC on non automatic weighing instruments RS 232C S V24 V28 7 bit parity even mark odd space transmission rates 150 19 200 baud 1 or 2 stop bits software hardware handshake applicable to the European Economic Area 80 Competence Series CP Series Model CP34001S OCE CP34001P OCE CP16001S OCE CP12001S OCE CP34000 0CE Type BF BL 500 BF BL 500 BF BL 500 BF BL 500 BF BL 500 Accuracy class Maximum capacity Max kg 34 8 16 34 16 12 34 Scale interval d g 0 1 0 1 0 2 0 5 0 1 0 1 1 Tare range subtractive g lt 100 of the maximum capacity Verification scale interval e g 1 1 1 1 1 Minimum capacity Min g 5 5 5 5 50 Response time average s lt 2 lt 2 lt 2 lt 2 lt 1 5 Range of use according to CD g 5 34 000 5 34 000
19. below along with the respective type accuracy class and number of the EC Type Approval Certificate Model Type Accuracy Class EC Type Approval No CP OCE BC BL 100 D D01 09 019 CP OCE BD BL 200 D D01 09 019 CP OCE BF BL 500 D D01 09 019 CP ACE BC BL 100 D D01 09 019 CP ACE BD BL 200 D D01 09 019 GC OCE BC BL 100 D D01 09 019 GP 0CE BD BL 200 en D01 09 019 SARTORIUS AG declares that its weighing instrument types comply with the requirements of the Council Directive on non automatic weighing instruments no 90 384 EEC of 20 June 1990 the associated European Standard Metrological aspects of non automatic weighing instruments No EN 45501 the amended currently valid versions of the national laws and decrees concerning legal metrology and verification in the Member States of the European Union the EU and the Signatories of the Agreement on the European Economic Area which have adopted this Council Directive into their national laws and with the requirements stipulated on the Type Approval Certificate for verification This Declaration of Type Conformity is valid only if the ID label on the weighing instrument has the CE mark of conformity and the green metrology Sartorius AG 37070 Goettingen Germany Signed in G ttingen 22 08 2002 ppe Koot President of the Mechatronics Division sticker with the stamped letter M the two digit number in large print sta
20. bit 1 or 2 stop bits Parity Mark odd even or space Transmission rates 150 to 19 200 baud Handshake mode Software or hardware 7 0 Three sided weighing pan Diameter of inner circle Z The cross hatched section can be fully utilized 74 Competence Series CP Series Model CP34001S CP34001P CP16001S CP12001S CP34000 Weighing capacity kg 34 8 16 34 16 12 34 Readability scale interval g 0 1 0 1 0 2 0 5 0 1 0 1 1 Tare range subtractive kg 34 34 16 12 34 Repeatability std deviation lt g 0 1 0 05 0 05 0 1 0 05 0 05 0 5 Linearity lt itg 0 2 0 2 0 2 0 2 0 5 Response time average s lt 2 lt 2 lt 2 lt 2 lt 1 5 Operating temperature range C 10 30 C 50 F to 86 F Allowable ambient operating temperature RQ 0 40 C 32 F to 104 F Sensitivity drift within 10 30 C lt K 2 10 External calibration weight kg 10 F1 10 F2 10 F1 10 F1 10 F2 of at least accuracy class Net weight approx kg 16 Pan size mm 300x400 Dimensions WxDxH mm 313x532x120 AC power source Ve AC adapter 230 V or 115V Power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO6Z rechargeable battery pack h 22 Selectable weight units Grams kilograms carats pounds ounces Troy ounces Hong Kong taels Singapore
21. equipment in installations and under ambient conditions requiring higher safety standards you must comply with the provisions as specified in the applicable regulations for installation in your country N Make sure that the voltage rating printed on the AC adapter is identical to your local line voltage A Warning when using pre wired RS 232 connecting cables The pin assignments in RS 232 cables purchased from other manufacturers may be incompatible with Sartorius balances scales Be sure to check the pin assignment against the chart on page 62 before connecting the cable and disconnect any lines marked Internally Connected The only way to switch the power off completely is to disconnect the AC adapter Connect only Sartorius accessories and options as these are optimally designed for use with your Sartorius balance scale Note on Installation The operator shall be responsible for any modifications to Sartorius equipment and for any connections of cables or equipment not supplied by Sartorius and must check and if necessary correct these modifications and connections On request Sartorius will provide information on the minimum operating specifications in accordance with the Standards for defined immunity to interference IP ratings CP34001S CP34001P CP34000 CP16001S and CP12001S meet IP44 requirements Additional models with readabilities gt 10 mg meet IP53 requirements Models with readabilities
22. handshake XON XOFF Hardware Handshake With a 4 wire interface 1 more character can be transmitted after CTS Clear to Send Software Handshake The software handshake is controlled via XON and XOFF When a device is switched on XON must be transmitted to enable any connected device to communicate Data Output by Print Command The print command can be transmitted by pressing CQ gt C gt or by a software command Esc P Automatic Data Output In the auto print operating mode data is output to the interface port without a print command You can choose to have data output automatically at defined print intervals with or without the stability parameter Whichever parameter you select the data will be output as the readouts appear on the bal ance scale display The display update frequency depends on the settings for Adapting the filter 1 1 x and Time dependent automatic printing 6 3 x If you select the auto print setting data will be transmitted immediately the moment you turn on the balance scale In the operating menu you can define whether automatic printing can be stopped by pressing CQ C Faster Output Speeds If you require output speeds faster than 10 Hz please contact Sartorius for information 61 Pin Assignment Chart Female interface connector 25 contact D Submini DB25S with screw lock hardware Male connector used please use connectors with the
23. is firmly in position Place the components listed below inside the chamber in the order given Base plate Pan support Weighing pan O Accessing the weighing chamber from the side Pull out the side panels one at a time CP622 Place the components listed below on the balance scale in the order given Pan support Weighing pan Balances Scales with a Rectangular Weighing Pan and a Weighing Capacity of up to 10 kg Place the components listed below on the balance scale in the order given Weighing pan Gem tray GP scales only Balances Scales with a Rectangular Weighing Pan and a Weighing Capacity over 10 kg Place the weighing pan on the balance scale Connecting the Balance Scale to AC Power Safety Precautions Use only original Sartorius AC adapters The protection rating on the AC adapter is 1P20 in accordance with EN60529 O See the Accessories for information on using an IP65 protected industrial AC adapter or an external rechargeable battery pack with your balance scale CP225D Insert the right angle plug into the jack on the electronics box All Other Balances Scales with a Weighing Capacity of up to 10 kg Insert the right angle plug into the jack on the balance scale Connect the power cable to the AC adapter on balances scales with weighing capacities of up to 10 kg O Use an original Sartorius AC adapter with a wide input voltage range 100 240 V
24. normal net weight printout is generated DIE key Toggling between component weight and total weight by pressing and holding CFD Printout of the total of the individual component weights T COMP Factory setting on CP ACE models only 35 Preparation Set parameters for Net Total Formulation O Select the application program in the operating menu Set parameters for automatic printout when component stored 2 Application programs Z Program selection 2 i 6 Net total m 1 Print for Application a4 i Print application parameters 4 it Off i 20 On all parameters i 3 On only main parameters Sc 7 3 Printout of net total formulation data 3 io Autom print of last net value 332 Autom print of tare value o Factory setting Factory setting on CP ACE models only Printout of Net total Formulation Data Comp2 278 1 g Second component T COMP 2117 5 g Sum of components T1 1821 5 g Tare weight 2nd tare memory N1 278 1 g Net weight Gross Tare 2nd Tare memory N 2099 6 g Net weight Gross Tare 36 Example Weighing in several components Settings Application program Net total formulation 2 6 Print application parameters On print all 7 2 Line format for printout 22 characters 2 Automatic printout of last net value 7 3 Step Key or instruction Display Printout 1 Turn on the balance scal
25. same specifications 25 pin D Submini DB25 with integrated shielded cable clamp assembly Amp 826 985 1C and fastening screws Amp type 164868 1 Z Warning When Using Pre wired RS 232 Connecting Cables RS 232 cables purchased from other manufacturers often have incorrect pin assignments for use with Sartorius balances scales Be sure to check the pin assignment against the chart below before connecting the cable and disconnect any lines marked Internally Connected e g pin 6 Failure to do so may damage or even completely ruin your balance scale and or peripheral device Pin Assignment Chart Pin 1 Shield Pin 2 Data output TxD Pin 3 Data input RxD Pin 4 Internal ground GND Pin 5 Clear to send CTS Pin 6 Internally connected Pin 7 Internal ground GND Pin 8 Internal ground GND Pin 9 Reset _ In Pin 10 Not connected Pin 11 12V Pin 12 Reset _ Out A For remote switch Pin 13 5V Pin 14 Internal ground GND Pin 15 Universal remote switch Pin 16 Not connected Pin 17 Not connected Pin 18 Not connected Pin 19 Not connected Pin 20 Data terminal ready DTR Pin 21 Ground input for external supply voltage Pin 22 Not connected Pin 23 Not connected Pin 24 Ext supply voltage input 12 30 V Pin 25 5V Hardware restart 62 Cabling Diagram For connecting a computer or other peripheral device to the balance scale using the RS 232 C V24 protocol and cabl
26. taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface Format Parity Transmission rates Handshake mode RS 232 V24 V28 7 bit ASCII 1 start bit 1 or 2 stop bits Mark odd even or space 150 to 19 200 baud Software or hardware 75 Specifications Verified models with EC type approval Competence Series CP Series Model CP225D OCE CP324S OCE CP224S OCE CP124S OCE CP64 0CE CP124S ACE Type BC BL 100 BC BL 100 BC BL 100 BC BL 100 BC BL 100 Accuracy class Maximum capacity Max g 80 220 320 220 120 64 Scale interval d mg 0 01 0 1 0 1 0 1 0 1 0 1 Tare range subtractive g lt 100 of the maximum capacity Verification scale interval e g 0 001 0 001 0 001 0 001 0 001 Minimum capacity Min g 0 001 0 01 0 01 0 01 0 01 Stabilization time average s lt 12 3 lt 3 lt 2 lt 2 lt 2 Range of use g 0 001 220 0 01 320 0 01 220 0 01 120 0 01 64 according to CD Allowable ambient operating temperature C 15 25 59 F to 77 F External calibration weight g 200 E2 200 200 E2 100 E2 50 E2 of at least accuracy class 100 E2 Net weight approx kg 7 6 6 5 6 5 6 5 6 5 Pan size inner diameter mm 80 Pan area cm 64 Weighing chamber height from pan to sliding cover mm 232 Dimensions WxDxH
27. weights can also be supplied with a DKD certificate if requested by adding 02 to the order number YCW 02 DKD certificates issued by the German Calibration Service are recognized throughout the member states of the Western European Calibration Cooperation 83 Product Order No Industrial AC adapter model ING1 for balances scales with weighing capacities of up to 10 kg protection rating IP65 in accordance with DIN VDE 0470 DIN EN 60529 for 230 V 69 71476 for 120 V 69 71480 Industrial AC adapter model ING2 for balances scales with weighing capacities over 10 kg protection rating IP65 in accordance with DIN VDE 0470 DIN EN 60529 for 230 V 69 71899 for 120 V 69 71500 Analytical draft shield chamber for CP423S CP323S CP323P CP153 GC2502 YDSO1CP Draft shield cover with opening for CP423S CP323S CP323P CP153 GC2502 YDSO2CP Data cable for PC connection 25 pin 7357312 for PC connection 9 pin 7357314 Adapter D Sub 25 pin 6965619 to D Sub 9 position length 0 25 m Universal remote control switch for remote control of one of the following functions configured in the balance scale menu DID CAD Door GD see Configuring the Balance Scale for details Foot switch with T connector YFSO1 Hand switch with T connector YHSO2 T connector YTCO1 A The T connector is not intended for use with multiple intelligent peripheral devices such as PCs or YDPO3 0CE printers
28. without built in motorized calibration weight External calibration 19 Calibration adjustment mode for models with built in motorized calibration weight Internal calibration 19 3 Calibration adjustment sequence Adjustment automatically follows calibration in a single operation 1 0 i Weight unit for calibration grams 1 ti 1SO GLP compliant printout off E iG 21 Internal Calibration for models with built in calibration weight only The built in calibration weight is standard equipment on all verified balances scales and on the following standard non verified models CP2P CP225D CP324S CP224S CP64 GC1603P GC803S GC803P Settings Calibration adjustment mode Internal calibration adjustment menu code 9 3 There is a motorized calibration weight within the balance scale housing which is applied and removed automatically for internal calibration Step Key or instruction Display Printout 1 Turn on balance scale CO H g if necessary 2 Tare the balance scale HH g if necessary 3 Start calibration adjustment a Internal weight is applied CAL automatically 4 Balance scale is calibrated _ oo g displayed only if menu CAL A code i0 is set 5 If the menu code for AduuSte calibration and adjustment CAL in a single step i id N is set the balance scale is adjusted automatically now 6 At this point adjustment co is completed CAL 7 Internal weight is unl
29. 0 01 0 02 0 01 0 05 Tare range subtractive g 4 200 3 200 3 200 2 200 Repeatability std deviation lt g 0 01 0 01 0 01 0 01 0 03 0 01 Linearity stg 0 02 0 02 0 02 0 02 0 05 0 02 Response time average s lt 1 5 Operating temperature range C 10 30 C 50 F to 86 F Allowable ambient operating temperature C 0 40 C 32 F to 104 F Sensitivity drift within 10 30 C lt K 2 1076 External calibration weight g 2 000 F1 2 000 F1 1 000 F1 1 000 F1 of at least accuracy class Net weight approx kg 4 0 Pan size mm 190x204 Pan surface cm 369 Dimensions WxDxH mm 213x342x88 AC power source Vw AC adapter 230 V or 115 V 15 20 Power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO8Z rechargeable battery pack h 27 Selectable weight units Grams kilograms carats pounds ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface Format Parity Transmission rates Handshake mode RS 232 V24 V28 7 bit ASCII 1 start bit 1 or 2 stop bits Mark odd even or space 150 to 19 200 baud Software or hardware 73 Competence Series CP Series
30. 3 i ie Pennyweights 0 64301493100 dwt wt 1713 31130 Milligrams 1000 00000000 mg mg E04 31H Parts per pounds 1 12876677120 o Ib 17145 3135 Chinese taels 0 02645547175 tl tle 17 16 3 16 Mommes 0 26670000000 m mom it Ee ae Austrian carats 5 00000000000 K K i718 318 Tola 0 08573333810 t tol 1719 319 Baht 0 06578947437 b bat iigb 31280 Mesghal 0 21700000000 m MS o Factory setting depends on model Not available in verified balances scales GP3202 readability with Taiwanese taels reduced by one decimal place GC1603P GC 803P S readability 0 0002 g GC2502 readability 0 001 g 3 Not available in the CP64 OCE 4 Not available in verified balances scales of accuracy class GD 1 2 Function Press CF gt to toggle between weight unit 1 and weight unit 2 49 Generating a Printout Purpose You can generate a printout of weights as well as other measured values and identification codes for documentation purposes You can format the printout to meet individual requirements Features Printouts generated automatically or manually at the press of a key weight or calculated value is output Line format Each value printed with up to 6 preceding characters for identification Print application parameters Printout of initialization values before printing measurement results 1SO GLP compliant printout Printout of ambient characteristics Printouts generated automatically or by pressing CQ
31. 6 1 Pan size inner diameter mm 80 80 Pan area cm 64 64 Weighing chamber height from pan to sliding cover mm 162 Dimensions WxDxH mm 213x342x270 AC power source Ve AC adapter STNG6 230 VAC or 115 VAC Power requirements 15 20 protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 average 8 Approx hours of operation with the YRBO5Z rechargeable battery pack h 22 22 Selectable weight units Grams milligrams carats Built in interface RS 232C S V24 V28 7 bit parity even mark odd space transmission rates 150 19 200 baud 1 or 2 stop bits software hardware handshake CD Council Directive 90 384 EEC on non automatic weighing instruments applicable to the European Economic Area 2 ZZ Three sided weighing pan Diameter of inner circle La The cross hatched section can be fully utilized 77 Competence Series CP Series Model CP423S 0CE CP323S 0CE CP323P 0CE CP153 0CE Type BD BL 100 BD BL 100 BD BL 100 BD BL 100 Accuracy class Maximum capacity Max g 420 320 80 160 320 150 Scale interval d g 0 001 0 001 0 001 0 002 0 001 0 005 Tare range subtractive g lt 100 of the maximum capacity Verification scale interval e g 0 01 0 01 0 01 0 01 Minimum capacity Min g 0 02 0 02 0 02 0 02 Response time average 5 lt 1 5 Range of use according to CD g 0
32. CR LE H L gt Space H Overload L Underload Error Codes 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 S t a t mM ot Be Omt opo a e o OBB SH CRE LE Space Error number ID code characters Meaning Stat Status T1 Tare Ti N Net N N1 Net N1 COMPxx _ Net total Component no T COMP _ Net total Total weighed in Qnt Counting Quantity wRef Counting Reference weight nRef Counting Reference sample quantity Prc Weighing in percent Reference percentage Wxx Weighing in percent Reference weight pRef Weighing in percent Reference percentage mDef Animal weighing No of measurements remaining x Net Animal weighing Calculated average 58 Data Input Format You can connect a computer to your balance scale to send commands via the balance scale interface port to control balance scale functions and applications The commands sent are control commands and may have different formats Control commands consist of up to 4 characters Each character must be transmitted according to the settings configured in the operating menu for data transmission Format for Control Commands Format 1 Esc CR LF Format 2 Esc CR LF Esc Escape CR Carriage return optional I Command character LF Line feed optional Command character Format 1 Meaning Weighing mode 1 very stable conditions Weighing mode 2 stable conditions Weighing mode 3 unstable conditions Weighing mode 4 ver
33. Tola Baht Mesghal v ee a a We We Menu 1 Weighing 1 1 through 17 1 8 Display accuracy 1 19 CAD key function 1 10 Calibration adjustment sequence 1 11 Weight unit for calibration weight H 2 Application 2 1 Program selection programs L 3 through 9 see following pages Setting cannot be changed on verified balances scales Not available in balances scales of accuracy class CD 2 On models with built in motorized calibration weight only 3 Not available in CP ACE models see previous page 1 1 1 1 1 1 1 1 1 1 2 pa 2 2 2 22 2 0 sn ov nn o AN digits Reduced by 1 digit External cal adj Internal cal adj CAD key blocked Calibrate then auto adjust in one operation Calibrate then manual adjust Grams Kilograms Pounds Weighing Toggle weight units Counting Weighing in percent Net total tare memory Animal weighing Averaging 27 vet N NS Menu 1 and2 3 Application parameters m 4 Application parameters Counting 5 through 9 3 1 E A NY xo see previous pages Weight unit 2 Display accuracy 2 Storage parameter Counting and Weighing in Percent Decimal places for calculations Animal activity Start Animal weighing Autom reference s
34. aft shield from the chamber Use your fingers to raise the draft shield carefully O Place these parts either in the accessory kit or in the original packaging The balance scale must be conditioned again any time it is set up in a new location see Installation Instructions on page 6 65 Care and Maintenance Service Regular servicing by a Sartorius technician will extend the service life of your balance scale and ensure its continued weighing accuracy Sartorius can offer you service contracts with your choice of regular maintenance inter vals ranging from 1 month to 2 years The optimum maintenance interval depends on the operating conditions at the place of installation and on the individual tolerance requirements Repairs Repair work must be performed by trained service technicians Any attempt by untrained persons to perform repairs may lead to hazards for the user 66 Cleaning A Unplug the AC adapter from the wall outlet mains supply If you have an interface cable connected to the balance scale port unplug it from the port A Make sure that no liquid enters the balance scale housing A Do not use any aggressive cleaning agents solvents or similar agents Clean the balance scale using a piece of cloth which has been wet with a mild detergent soap After cleaning wipe down the balance scale with a soft dry cloth Cleaning Stainless Steel Surfaces Clean all stainless steel par
35. ample updating see next page Setting cannot be changed on verified balances scales 1 Not available in the CP64 0CE 2 Not available in verified balances scales of accuracy class 28 N 311 312 3 1 3 3 14 315 316 3 17 318 3 19 3 1 10 3111 3 1 12 3 1 13 3 1 14 3 115 3 1 16 3 117 3 1 18 3 1 19 3 1 20 r321 3 25 351 352 3 61 3 6 2 3 6 3 364 3 71 372 373 3 81 3 8 2 411 412 Grams Display o Grams Display g Kilograms Carats Pounds Ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels Grains Pennyweights Milligrams 2 Parts per pound Chinese taels Mommes Austrian carats Tola Baht Mesghal All digits Reduced by 1 digit With stability internal resolution With higher stability None 1 decimal place 2 decimal places 3 decimal places Calm Normal Active Manual start Automatic start Off On RS N NS Menu 1 through 3 5 Data interface H 6 Print for weighing 7 through 9 er we we see previous page 5 1 Baud rate 7 51 51 5 1 5 1 5 1 5 1 5 1 1 5 2 Parity 52 5 2 m52 2 5 3 No of stop bits 7 53 53 5 4 Handshake mode 54 54 5 4 5 5 Communications mode 5 5 5 5 6 1 Manual auto print 6 1 mode 6 1 H6 1 6 1 H6 1 6 1 6 2 Stop automatic 6 2 printing 62 6 3 Time dependent 63 autom printing 63 6 4 Tare the balance scale 6 4 after ind pr
36. c and Precision Balances Microbalance CP2P Below Balance Under Scale Weighing A port for a below balance under scale weighing hanger is located on the bottom of the balance scale You can order the hanger directly from Sartorius for balances scales with a weighing capacity over 12 kg see Accessories Open cover plate on the bottom of the balance scale Using the built in hanger 1 Attach the sample e g using a suspension wire to the hanger Bore hole 2 Carefully fasten the special hanger or order a hanger directly from Sartorius O If necessary install a shield for protection against drafts Important Note Concerning Verified Balances Scales Approved for Use as Legal Measuring Instruments in the EU The below balance under scale weighing port may not be opened or used when an approved balance scale is being operated as a legal measuring instrument Remove the brass screw Suspend the below balance weighing hook supplied from the hanger If necessary install a shield for protection against drafts including the Signatories of the Agreement on the European Economic Area Example Simple Weighing Setting in Balance Scale Operating Menu Line format for printout For other applications GLP 7 2 2 Step Key or instruction Display Printout 1 Turn on the balance scale lt p Log Self test is performed followed by automatic
37. cating the active program Press here to start calibration adjustment 10 Delete Clear Function This key is generally used to interrupt cancel functions for example to end an application program to interrupt calibration adjustment routines On Off key Switches the display on off The balance scale may remain in standby mode depending on the settings Symbol indicating that the cal ibration adjustment function is active Symbol indicating that the animal weighing program is active with automatic start function Symbol indicating stand by mode or zero range Weight readout in the selected weight unit Basic Weighing Function Purpose The basic weighing function is always accessible and can be used alone or in combination with an application program counting weighing in percent etc Features Taring the balance scale You can tare the balance scale within the entire weighing range Assigning IDs to weights as needed Printing weights Using Verified Balances Scales as Legal Measuring Instruments in the EU The type approval certificate for verification applies only to non automatic weighing instruments for operation with or without auxiliary measuring devices you must comply with the regulations of your country applicable to the place of installation of your balance scale Before using the balance scale as a legal measuring instrument calibrate and adjust it at the pla
38. ce scale from AC power before you connect or disconnect a peripheral device printer or PC to or from the interface port Warmup Time To deliver exact results the balance scale must warm up as listed below after initial connection to AC power or after a relatively long power outage Model CP2P microbalance at least 4 hours All other precision and analytical models at least 30 minutes Only after this time will the balance scale have reached the required operating temper ature Using Verified Balances Scales as Legal Measuring Instruments in the EU The balance scale must warm up for at least 24 hours after initial connection to AC power Leveling the Balance Scale Purpose To compensate for unevenness at the place of installation To achieve perfectly horizontal positioning of the balance scale for consistent reproducibility Always level the balance scale again after any time it has been moved including the Signatories of the Agreement on the European Economic Area Leveling Balances Scales with a Weighing Capacity of up to 10 kg Only the 2 front feet are used for leveling Retract the 2 rear feet on models with rectangular weighing pans only Turn the 2 front feet as shown in the diagram until the air bubble is centered within the circle of the level indicator In most cases this will require several adjustment steps For weighing heavy samples Extend the 2 rear feet until they to
39. ce Ist animal in bowl Weight value fluctuates due to animal activity 5 Start automatic animal weighing CF gt z The balance scale delays eu starting the subweighing 9 operation until successive iB subweights lie within a the range defined i 6 After 20 subweighing operations 4Yihiga the arithmetic average x Net mDef 20 is displayed x Net 410 1 g 7 Unload the balance scale oo g 8 Weigh next animal if applicable 48 Next weighing series begins automatically Toggle between Weight Units Menu code 2 td Display symbol R Purpose With this application program you can switch the display of a weight value back and forth between two weight units Configure the Toggle Weight Units application in the operating menu See Configuring the Balance Scale menu code 2 Toggle weight units factory setting in GC and GP scales Menu code Unit Conversion Display Printout Weight unit 1 Weight unit 2 iad 3110 Grams 1 00000000000 o o 1120 3120 Grams 1 00000000000 g g 113 Iia Kilograms 3 0 00 100000000 kg kg i tT4o 344 Carats 5 00000000000 ct ct 115 315 Pounds 0 00220462260 Ib Ib 116 316 Ounces 0 03527396200 oz oz iG 31 Troy ounces 0 03215074700 ozt ozt i176 318 Hong Kong taels 0 0267 1725000 tl tlh 119 319 Singapore taels 0 02645544638 tl tls 171g 31 Taiwanese taels 0 02666666000 tl tlt II I Grain 15 4323583500 GN GN iT ie
40. ce of use using the built in motor ized calibration and adjustment weight span adjustment device see the Calibration Adjustment section in this chapter The temperature range C indicated on the verification label may not be exceeded during operation Example BD BL 200 10 30 C including the Signatories of the Agreement on the European Economic Area 16 Working with CP2P Models Working with the microbalance requires a steady hand and a smooth uninterrupted technique Use forceps or other suitable utensil to place the sample on the weighing pan Perform a number of test measurements before you begin weighing to allow the temperature inside the weighing chamber to adjust to the ambient temperature outside the chamber Otherwise if the chamber door was closed for a longer period of time prior to beginning weighing the sudden change in temperature inside the chamber when you open the door might affect the weight readout This is why we recommend starting with a series of test measurements the repeated opening and closing of the weighing chamber door at the same rate as you will be doing during the actual weighing sequence will both compensate this differ ence in temperature to some extent and help you develop a smooth working rhythm Place the sample gently on the weighing pan The weight readout should stabilize within 15 to 20 seconds The degree of precision attained increases in pro
41. ce weight The following Sartorius terminals can be used for sample weighing in conjunction with a reference balance scale For QC scales menu code amp 8 2 For FB FC LA LP series balances scales menu code 8 8 3 For isi terminals menu code 8 8 4 Please order the required connecting cables directly from Sartorius The following settings must have the same configurations in both balances scales Counting program Weight units Settings in the CP balance Set menu codes i candice All data interface parameters Baud rate Parity Number of stop bits Handshake mode Transfer Function in the CP Balance Press the CFD key The reference value is transferred to the reference balance scale Reference Balance Scale O See the operating instructions of the balance scale in question for details Printout Counting nRef wRef Ant 10 DAR 500 pes Preparation Set parameters for the Counting program O Select the application program in the operating menu Set the following parameters 2 Application programs 2 i Program selection 2 4 Counting 3 Application parameters 3 5 Storage parameter 35 With stability internal resolution 3 5 co With higher stability 4 Application parameters for Counting 4 i Autom ref sample updating ff n o y Ly 100 eo B Extra functions B amp Reference balance scale 8 B io Off 8 amp Z On for QC scales
42. ck 15 hours see Specifications for hours of operation To recharge the battery pack Unplug the AC adapter from the balance scale and plug it into the battery pack Carrying case for models with analytical draft shield chamber YDBO1CP for models with weighing capacities up to 10 kg and without analytical draft shield chamber YDBO2CP 82 Calibration weights For model Accuracy Weight Order no class OIML in grams CP2P E2 1x2 YCW3228 00 CP64 E2 1x50 YCW4528 00 CP124S GC803S GC803P E2 1x100 YCW5128 00 CP323P CP153 F1 1x100 YCW5138 00 CP225D CP224S E2 1x200 YCW5228 00 CP324S GC1603P E2 1x200 YCW5228 00 1x100 YCW5128 00 CP423S CP323S GC2502 F1 1x200 YCW5238 00 CP622 F2 1x500 YCW5548 00 CP3202P CP2202S F1 1x1000 YCW6138 00 CP4202S CP3202S GP3202 CP4201 CP2201 F1 1x2000 YCW6238 00 CP8201 CP6201 F1 1x5000 YCW6538 00 CP34001S CP34001P CP16001S CP12001S CP34000 F1 1x10000 YCW7138 00 SartoConnect data transfer software YSCO1L for connecting your Sartorius balance scale to a PC running the Windows 95 98 or NT operating system This software lets you transfer the data recorded by your balance scale to any PC application program e g Excel Density determination kit for CP225D CP324S CP124S CP64 YDKO1 Antistatic weighing pan for CP225D CP324S CP124S CP64 YWPO1CP Dust cover Information for precision balances scales on request All
43. diately gt Lock the equipment in a secure place to ensure that it cannot be used for the time being Safe operation of the balance scale with the AC adapter is no longer ensured when there is visible damage to the AC adapter the AC adapter no longer functions properly the AC adapter has been stored for a relatively long period under unfavorable conditions Maintenance and repair work may be performed only by service technicians who are authorized by Sartorius and who have access to the required maintenance manuals have attended the relevant service training courses We recommend having the power supply inspected by a certified electrician at regular intervals according to the checklist given below Insulating resistance gt 7 megaohms measured with a constant voltage of at least 500 V at a 500 kohm load Leakage current lt 0 05mA measured with a properly calibrated multimeter 67 Instructions for Recycling the Packaging To ensure safe shipment your balance scale has been packaged using environmentally friendly materials After successful installa tion of the balance scale you should return this packaging for recycling For information on recycling options including recycling of old weighing equipment contact your municipal waste disposal center or local recycling depot 68 Overview Specifications Competence Series CP Series
44. e if necessary Place empty container on the balance scale Tare the balance scale Add first component Store component data Add next component Store component data Weigh in further components if desired Fill to target if desired Repeat steps 5 and 6 Press and hold CFD 2 sec mm Li COMP1 9 ner 120 5 g 3 wn Ko nn LILLI yer COMP2 70 5 g 5 ou we 37 Step Key or instruction Display Printout 10 Add last component 11 Store component data 12 Display total weight 38 i2 5g G mm LILI O ye COMP 3 12 5 g 203 59 T COMP 203 5 g Counting Menu code 2 4 Display symbol s amp Purpose With the Counting program you can determine the number of parts that each have approximately equal weight Features The minimum load is equal to one digit defined according to the resolution of the active weight unit Press and hold the CFD key 2 seconds to set the reference sample quantity Configure the resolution used when reference sample quantity is stored and piece counts are calculated Optional automatic output of the piece count and average piece weight to the data interface port when the menu code 7 i print application parameters is set Long term storage of the last reference sample quantity nRef entered Toggling between piece count and weight by pressing CF gt
45. ers 722 For other apps 22 characters 731 Autom printout of last net value 732 Autom printout of tare value 811 Parameter settings alterable 812 Parameter settings read only 821 On 822 off 831 Accessible 832 Blocked 841 DIE key 8 42 key 8 43 QAD key 8 4 4 CFD key 8 45 Cer gt key 8 5 1 Off on standby 8 5 3 Off on 8 54 Automatic on 81 Off 8 8 2 On for QC scale 8 8 3 On for FB FC LA LP balance scale 884 On for isi terminal 10 1 No 1SO GLP printout 8 10 2 For calibration adjustment only 8 10 3 Always on 9 1 Restore 9 2 Do not restore Setting IDs Time Date and Display Brightness Purpose Configuring measurement environment parameters for ISO GLP compliant data records Setting date and time for ISO GLP compliant records only Adapting display to ambient lighting conditions Features Enter up to 8 characters to identify a measurement series Permissible characters include the numbers 0 through 9 the dash or minus sign and spaces Leading zeroes are output as spaces Date and time of beginning and end of series recorded Display brightness 0 off levels of brightness 1 through 9 Activate the ID number date and time configuration menu Press CO to turn the balance scale off and back on again While all display segments are lit press CFD briefly Scroll upward 7 press Scroll right press CQ C gt Press to confirm input and toggle between ID
46. es up to 15 m 50 ft long V24 CELAN Peripheral Device PC PC 25 pin or 9 pin 2 3 20 4 3 2 5 8 6 6 7 5 Type of cable AWG 24 specification 63 Error Codes Error codes are shown on the main display for 2 seconds The program then returns automatically to the previous mode e g weighing Display Cause Solution No segments appear on the display No AC power is available The AC adapter is not plugged in Check the AC power supply Plug in the AC adapter H The load exceeds the Unload the balance scale balance scale capacity L or Err 54 Something is touching Move the object that is the load plate touching the load place Err dt Data output not compatible Change the configuration in with output format the operating menu Err ae Calibration parameter Calibrate only when zero not met e g is displayed balance scale not zeroed Press to zero the balance scale balance scale is loaded Unload the balance scale Err 0 The key is blocked Press cr to clear the when there is data in tare memory and release the second tare memory the tare key net total only 1 tare function can be used at a time Err ii Tare memory not allowed Press Err dd Weight is too light or there is no Increase the weight on the sample on the balance scale balance scale Err 30 Interface port for printer Reset the menu restore
47. ge Storage parameter rounding off factor for storing the reference weight to calculate the percentage can be configured Configuration of decimal places displayed with a percentage Optional automatic output of the reference weight Wxx and reference percentage to the data interface port when the menu code 7 i print application parameters is set Long term storage of the last reference percentage pRef entered Toggling between percentage and weight by pressing CF Function Keys Begin calculation of percentage Current weight value stored as reference weight Wxx to be loaded at initialization End application program clear initialization data Changing the reference a Press and hold CFD 2 sec Current reference percentage is displayed O Press CFD briefly to change the value press repeatedly until the desired reference percentage is displayed Quantities to choose from 1 2 5 10 20 50 100 Store setting in long term memory Press and hold CFD 43 Printout Weighing in Percent pRef 100 Wxx 111 6 g Prc OA Tt 44 Preparation Set parameters for the Weighing in Percent program O Select the application program in the operating menu Set the following parameters 2 Application programs Z Program selection 45 Weighing in percent 3 Application parameters 3 5 Storage parameter 3 5 io With stability internal resolution 1 3 502 W
48. gram Store component Toggle between component weight and total weight net total formulation change reference quantity counting reference percentage weighing in percent or number of measure ments animal weighing End application program delete Using Verified Balances Scales as Legal Measuring Instruments in the EU All application programs can be selected on balances scales used as legal measuring instruments Calculated values can be indicated as follows Percent Piece count counting pcs Computed value 0 including the Signatories of the Agreement on the European Economic Area 34 Net Total Formulation Menu code 2 i 6 amp Display symbol amp Purpose With this application program you can weigh in different components up to a defined total You can also print out the total weight and the individual weights of the components Features Tare function Weigh up to 99 components from 0 to a defined total component weight Store component weights Store xx comp with display zeroed automatically after value is stored and automatic printout print application parameters either of the last component weight net value or of the total weight tare value Clear component memory when weighing series is canceled by pressing CF total weight printed if Print all parameters is selected in the operating menu otherwise the
49. gy sticker S Protective seal for accuracy classes CIM and iD only MD Metrological data T Plate with model designation Example of descriptive plate on a weighing instrument already verified k SARTORIUS AG GOT TINGEN Germany BD BL 200 201 09 019 ce01 ee Loa CHD mas Example of plate with model designation fr SARTORINS AG GETTINGEN Beman CE BL Type BC BL 100 BD BL 200 BF BL 500 PPCP220802e EC type approval certificate DO1 09 019 89 Sartorius AG Weender Landstrasse 94 108 37075 Goettingen Germany Phone 49 551 308 0 Fax 49 551 308 3289 www sartorius com Copyright by Sartorius AG Goettingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the tight to make changes to the technology features specifications and design of the equipment without notice Status May 2003 Sartorius AG Goettingen Germany Printed in Germany on paper that has been bleached without any use of chlorine W3A000 KT Publication No WCP6001 e03058
50. haracter format 1 start bit 7 bit ASCII parity 1 or 2 stop bits Handshake 2 wire interface via software XON XOFF 4 wire interface via hardware handshake lines CTS DTR Operating mode SBI Data output format of the balance scale 16 or 22 characters Factory settings Transmission rate 1 200 baud 5 4 Parity Odd 5 3 Stop bits 1 stop bit 53 Handshake Hardware 2 characters after CTS 5 42 Operating mode Standard SBI 55 Print manually automatically Manual at stability 6 2 Preparation see Pin Assignments and Pin Assignment Chart Identification of Non Verified Digits Non verified digits for e d are auto matically identified on the printout Select universal printer code 55 2 Brackets see examples are used to identify a maximum of 2 decimal places Up to 7 digits max can be identified if 8 digits are shown they are not identified 55 Output Format with 16 Characters Display segments that are not activated are output as spaces The following characters can be output depending on the characters displayed on the balance scale Normal Operation Position 1 2s Bin 4 5 16 TS 10 11 12 13 14 15 16 DD D D D U U CR LF or A res or T Space CR Carriage return D Digit or letter LF Line feed U Unit symbol Special Codes Position 1 2 3 4 5 6 8 10 11 12 13 14 15 16 or H or E or
51. he sample on the balance scale must not differ from the nominal weight by more than 2 You can use any of the following weight units to calibrate adjust g kg Ib I ii to 3 You can block calibration adjustment of the balance scale Select menu code 9 7 and Close the menu access switch on the back of the balance scale You can have the calibration adjustment results documented in a ISO GLP compliant printout see page 53 For service technicians only External Calibration in Verified Balances Scales of Accuracy Class GD External calibration can be made accessible only after removing the verification control seal In this case the validity of the verification becomes void and the balance scale must be re verified Calibration Adjustment Sequence You can configure the operating menu so that adjustment automatically follows calibra rime tion in a single operation i 5 or the operator chooses whether to end the calibration adjustment routine or cin have adjustment performed i 10 2 If there is no deviation or if the difference is within the effective require ments for accuracy of measurements it is not necessary to adjust the balance scale In this case you can end the calibration routine following calibration Two keys are active at that point start adjustment end the calibration adjustment routine Factory Settings Calibration adjustment mode for models
52. ient conditions With this program the balance scale calculates the weight as the average of a defined number of individual weighing operations also referred to as subweighing operations Features Animal weighing started manually or automatically Minimum load threshold for starting animal weighing for automatic start 100 display intervals for manual start 50 display intervals Automatic start Begin the averaging operation by pressing CFD AUTO is displayed dur ing weighing to indicate that the following values will be averaged automatically Animal activity Averaging begins automatically once two subweights are measured within a predefined tolerance range calm 2 normal 5 active 20 Number of weighing operations for calculation of an average mDe f can be set before the beginning of each series Number of remaining weighing operations in the current series is shown during weighing 46 e gt Arithmetic average displayed as a result in the pre set weight unit identified by the A The amp symbol flashes during this time Toggling between weighed and calculated results by pressing CFD after initialization Unload threshold is one half of the minimum load Balance scale returns to the basic weighing mode when unloaded i e when the load is below the unload threshold Function Keys Activate animal weighing program End application program delete result i
53. initial tare function 2 Place container on balance scale 115 g in this example 11 5 g 3 Tare the balance scale UU g 4 Place sample in container uh 1300 g on balance scale in this example 132 g 6 Print weight gt N 132 0 g Calibration Adjustment Purpose Calibration is the determination of the difference between the weight readout and the true weight mass of a sample Calibration does not entail making any changes within the balance scale Adjustment is the correction of any difference between the measured value displayed and the true weight mass of the sample or the reduction of the difference to an allowable level within the maximum permissible error limits Using Verified Balances Scales as Legal Measuring Instruments in the EU Before using your balance scale as a legal measuring instrument you must perform internal calibration at the place of installation after the warmup period Features Calibration adjustment can be performed only when there is no load on the balance scale the balance scale is tared the internal signal is stable lf these conditions are not met an error message is displayed Err Ge Adjustment can be performed automatically following calibration menu code id or manually at operator discretion after calibration i0 2 including the Signatories of the Agreement on the European Economic Area 20 The weight displayed for t
54. intout 64 see next page Auto print when load change is gt 10 d and stability is reached no prin in load value is lt 5 d not available in CP ACE models ANDO APWN PUN 150 baud 300 baud 600 baud 1 200 baud 2 400 baud 4 800 baud 9 600 baud 19 200 baud Mark Space Odd Even 1 stop bi 2 stop bits Software Hardware 2 char after CTS Hardware 1 char after CTS SBI ASCII Universal printer Manual without stability with CQ gt C key Manual at stability with CQ gt C key Manual at stability with CQ gt C key Automatic without stability Automatic at stability Automatic when load changed Manual C gt C amp key Not stoppable 1 display cycle 2 display cycles Off On out until residual difference 29 Menu 4 A r ee se we we m 1 through 6 see previous pages 7 Printing with 7 1 Print application application programs parameter 7 2 Line format of printout 7 3 Printout with Net total program 8 Extra 8 1 Menu functions 9 Reset menu Acoustic signal Keypad 8 4 External switch function 8 5 Power on mode for balance scale 8 8 Reference balance scale 8 10 1SO GLP compliant printout 9 Factory settings Setting cannot be changed on verified balances scales 30 8 8 4 ROJ we KO wer gat we 711 off 712 On all parameters 713 On main parameters ony 721 For raw data 16 charact
55. ith higher stability 3 6 Decimal places i none Zo 1 decimal place 3 2 decimal places 4 3 decimal places o Factory setting Reference percentage Reference weight net xx Calculated reference percentage Example Determining residual weight in percent Settings Menu Weighing in percent program menu code 15 1 Print application parameters On all parameters menu code 7 i Line format for printout 22 characters menu code 7 2 Reference percentage rEF 155 Step Key or instruction Display Printout 1 Turn on the balance scale if necessary Place empty container cc g on balance scale Tare the balance scale ag g Place sample equal to 100 of reference percentage on the balance scale in this example 111 6 g Initialize the balance scale rEF iad displayed briefly 1116 ULL pRef 100 Wxx 111 6 g Remove container for example to treat sample in this example the sample is now dried Place container with sample 44 5 on the balance scale again after treatment Optional print percentage Cy Pro 94 9 Display residual weight and Cer 105 99 delete reference value Optional print net DD N 105 9 g residual weight 45 Animal Weighing Averaging Menu code 2 i7 Display symbol Purpose Use this program to determine the weights of unstable samples e g live animals or to determine weights under unstable amb
56. le on a stable even surface Avoid placing the balance scale in close proximity to a heater or otherwise exposing the balance scale to heat or direct sunlight Protect the balance scale from drafts that come from open windows or doors Avoid exposing the balance scale to extreme vibrations during weighing Protect the balance scale from aggressive chemical vapors Do not expose the balance scale to extreme moisture over long periods Level the balance scale at the place of installation Conditioning the Balance Scale Moisture in the air can condense on the surfaces of a cold balance scale whenever it is brought into a substantially warmer place If you transfer the balance scale to a warmer area make sure to condition it for about 2 hours at room temperature leaving it plugged into AC power Seal on Balances Scales Verified for Use in Legal Metrology in the EU EU legislation requires that a control seal be affixed to verified balances scales of accuracy class GD The control seal consists of a sticker with the Sartorius logo This seal will be irreparably damaged if you attempt to remove it If the seal is broken the validity of verification will become void and you must have your balance scale re verified Including the Signatories of the Agreement on the European Economic Area Setting up the Balance Scale Model CP2P Remove the adhesive tape from the chamber doors Please the components listed be
57. low inside the chamber in the order given Interior draft shield Weighing pan Modell CP2P F 1 Weighing filters of up to 125 mm Lift the chamber lid gently and turn it to the left or right Place the components listed below inside the chamber in the order given Interior draft shield Filter pan Cover the sample filter with the lid or 2 Weighing with the standard weighing pan 20 mm Lift the chamber lid gently and turn it to the left or right Place the components listed below inside the chamber in the order given Interior draft shield Spacer ring Weighing pan Balances Scales with an Analytical Draft Shield Chamber A Move the sliding lock on the back of the draft shield to the right open position Position the draft carefully on the balance scale Secure the draft shield in position by moving the sliding lock device on the back of the balance scale to the left while pressing down gently on the floor of the draft shield Place the components listed below inside the chamber in the order given Base plate Shield disk Weighing pan Gem tray GC models only Connecting the Electronics Box to Model CP225D OCE Insert the connector on the cable in to the socket on the electronics box Balances Scales with a 3 sided Draft Shield Place the draft shield on the balance scale with the cover opening in front on the right Turn the draft shield clockwise until it
58. m capacity Verification scale interval e g 0 1 0 1 0 1 0 1 Minimum capacity Min g 0 5 0 5 0 5 0 5 Response time average s lt 1 5 Range of use according to CD g 0 5 4 200 0 5 3 200 0 5 3 200 0 5 2 200 Allowable ambient operating temperature C 10 30 50 to 86 F Net weight approx kg 4 7 Pan size mm 190x204 Pan area cm 369 Dimensions WxDxH mm 213x342x88 AC power source Vw AC adapter STNG6 230 VAC or 115 VAC Power requirements 15 20 protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 average 8 Approx hours of operation with the YRBO5Z rechargeable battery pack h 27 Selectable weight units Grams kilograms carats Built in interface 1 CD Council Directive 90 384 EEC on non automatic weighing instruments RS 232C S V24 V28 7 bit parity even mark odd space transmission rates 150 19 200 baud 1 or 2 stop bits software hardware handshake applicable to the European Economic Area 79 Competence Series CP Series Model CP622 0CE CP8201 0CE CP6201 0CE CP2201 0CE Type BD BL 200 BD BL 200 BD BL 200 BD BL 200 Accuracy class Maximum capacity Max g 620 8 200 6 200 2 200 Scale interval d g 0 01 0 1 0 1 0 1 Tare range subtractive g lt 100 of the maximum capacity Verification scale interval e g 0 1 1 1 0 1 Minimum capacity Min g 0 5 5 5 Response time
59. nds for the year in which the mark has been affixed C 02 If these marks are not on the ID label this Declaration of Type Conformity is not valid Validity can be obtained for example by submitting the weighing instrument for final action to be taken by an authorized representative of SARTORIUS AG The period of validity of this Declaration of Type Conformity shall expire upon any tampering with repair or modification of this weighing instrument or in some Member States on the date of expiration The operator of this weighing instrument shall be responsible for obtaining an authorized renewal of the verification such as subsequent or periodic verification of the weighing instrument for use as a legal measuring instrument J Rehwald Head of thg Production Department Mechatrokfes Weighing Technology Division OAW 113 2 02 96 P106ea01 doc 87 88 394 06 bb Physikalisch Technische Bundesanstalt PIB Braunschweig und Berlin Zulassungsinhaber Issued to Rechtsbezug In accordance with Bauart tn respect of Zulassungsnummer Approval number G ltig bis Valid until Anzahl der Seiten Number of pages Gesch ftszeichen Reference No Benannte Stelle Notified Body im Auftrag EG Bauartzulassung EC type approval certificate Sartorius AG Weender Landstra e 94 108 37075 G ttingen Bundesrepublik Deutschland 13 des Gesetzes ber das
60. nterrupt measuring operation Changing the number of subweighing operations Press and hold CFD 2 sec Current number of subweighing operations is displayed Press CFD briefly to change the value press repeatedly until the desired number is displayed Quantities to choose from 5 10 20 50 100 Store setting in long term memory Press and hold Cr gt Printout Animal Weighing mDef 20 x Net 401 1 g Preparation Set parameters for the Animal Weighing program O Select the application program in the operating menu Set the following parameters 2 Application programs 2 Program selection Z i i Animal weighing 3 Application parameters 3 7 Animal activity 3 7 Calm 2 of the animal object 3 7 20 Normal 5 of the animal object 3 74 Active 20 of the animal object 3 8 Start 3 B i Manual 3 B 2 o Automatic o Factory setting Number of subweighing operations Calculated average 47 Example Determining animal weight with automatic start of 20 subweighing operations Settings Menu Animal weighing program menu code 7 Print application parameters On all parameters menu code 7 ic Line format for printout 22 characters menu code 72 2 Step Key or instruction Display Printout 1 Turn on the balance scale Ce if necessary 2 Place animal weighing bowl ecb g on the balance 3 Tare the balance scale oo g 4 Pla
61. number time and date Store settings and exit menu Press and hold 2 sec No display backlighting on models CP2P CP225D and CP225D 0CE 31 Example Setting the time date and display brightness Step Key or instruction Display Printout 1 Turn off the balance scale 2 Turn on the balance scale and O Move cursor in 8 character ID O 32 while all segments are displayed Set or change 1D Confirm ID and activate time Select 24 hour clock H or 12 hour clock P Toggle between hours minutes and seconds Synchronize seconds with reference clock Confirm time and activate date Set date Day Month and if desired set Year Confirm date and activate display brightness cD gt CFD briefly repeatedly repeatedly DED repeatedly ED repeatedly ED repeatedly BARRRBAHK gt 0 5 AUTOCALE RB BYLCNETAIQ E 1 nn DHH H i0 14 19 Hiv 15 19 Step Key or instruction Display Printout 9 Set display brightness 10 Store settings and exit the menu or O Exit menu without storing changes gt Restart application repeatedly Press and hold 2 sec I m 1 LA iF I ABBA ABBE ES gt 0 S AUTOCALERBKMBYLGCNETAIQE 33 Application Programs Function Ke press and hold for gt 2 seconds CP ys Start application pro
62. oaded ou g displayed only if menu item 0 is selected 22 External Calibration Settings Calibration adjustment mode External calibration adjustment menu code 3 3 The weight required for calibration adjustment is defined in the factory settings see Specifications Step Key or instruction Display Printout 1 Turn on the balance scale lt gt ag g if necessary 2 Tare the balance scale ag g if necessary 3 Start calibration adjustment 5000 0 g Calibration weight is displayed CAL A without a unit symbol 4 Apply the prompted calibration weight in this example 5000 g 5 Balance scale is calibrated _ ie g displayed only if menu CAL A code IU 2 is set 6 If the menu code for Adu Se calibration and adjustment CAL in a single step i id 1 is set the balance scale is now adjusted automatically 7 At this point adjustment CL is completed CAL 8 After calibration the weight 5000 0 g unit is shown CAL 9 Remove the calibration weight ug 23 Configuring the Balance Scale Purpose You can configure your balance scale to meet individual requirements by selecting from parameter settings in a software menu Key functions during configuration Activate the settings menu Press QOD to turn the balance scale off and back on again While all display segments are lit press briefly Scroll upward 1 press Scroll right press CD CD Confirm inpu
63. of standard accessories AC adapter Dust cover Gem tray GC scales only Filter pan and lid Spacer model CP2P F only The kit of standard accessories contains the following Weighing pan Interior draft shield Hanger for below balance weighing 1 brush 1 pair of forceps 1 piece of lint free cloth Equipment Supplied The equipment supplied includes the components listed below CP Balances with Readability of lt 0 1 mg GC Scales Balance scale with display and control unit Electronics box model CP225D only Draft shield with base plate not available for the CP64 WDS AC adapter Weighing pan Shield disk Dust cover Gem tray GC scales only CP Balances with Readability of 1 mg Balance with display and control unit Draft shield with cover AC adapter Z Weighing pan Pan support Base plate CP Balances with Readability of 0 01 g 0 1 g GP Scales Balance scale with display and control unit AC adapter Weighing pan Pan support model CP622 only Gem tray GP scales only CP34001S CP34001P CP16001S CP12001S CP34000 Balance with display and control unit AC adapter Weighing pan Installation Instructions Your balance scale is designed to provide reliable weighing results under normal ambient conditions When choosing a location to set up your balance scale observe the following so that you will be able to work with added speed and accuracy 6 Set up the balance sca
64. p BY 4LGNETAIO E Mi UD ABBA AEO S gt 0 5 AUTOCAL KA RB BY LGNETAIO E 25 Parameter Settings Overview o Factory settings V User defined setting x oe EN NS Menu 1 Weighing 2 through 9 1 1 1 8 N N ar Adapt filter ambient conditions Application filter Stability range The stability symbol is displayed when the value is stable within this number of digits Tare function Auto zero Weight unit 1 see next page see next pages Setting cannot be changed on verified balances scales Not available in the CP64 0CE 2 Not available in verified balances scales of accuracy class 26 a NS 111 F112 1 13 114 12 1 122 13 1 132 1 3 3 134 F135 136 151 152 161 162 171 1 72 1 73 174 1 75 1 76 177 1 78 1 79 1 710 1711 1 712 1 713 1714 1 715 1716 1 717 1 718 1 719 1 7 20 x08 ROSS ee KOX Very stable conditions Stable conditions Unstable conditions Very unstable conditions Final readout Filling mode 1 4 digit 1 2 digit 1 digit 2 digits 4 digits 8 digits Without stability After stability On off Grams Display 0 Grams Display g Kilograms Carats Pounds Ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels Grains Pennyweights Milligrams Parts per pound Chinese taels Mommes Austrian carats
65. portion as each weighing operation in a sequence of measurements becomes more identical Preparation O A circle displayed in the upper right hand corner indicates that the balance scale has been disconnected from power the power cable was unplugged or due to power failure Turn on the balance scale Press Gi m fpes o gt All symbols on the display light up briefly GN HABE eae 30 S AUTOCAL KA RB B LGNETAIO E The balance scale performs a display test N F c Inn 3 _ EESE tuu To change configurations see the chapter entitled Configuring the Balance Scale To load factory set default configurations see Configuring the Balance Scale menu code To tare the balance scale Press When the balance scale is switched on the lt is displayed until you press a key a If the lt gt symbol is displayed during operation this indicates that the processor is performing a function and cannot receive further commands at the moment Additional Functions Turning off the balance scale Press Ci 0 A zero in the lower left hand corner indicates that the balance scale has been switched off and is in stand by mode Filter Weighing with Model CP2P F The CP2P F filter microbalance comes with a filter pan that has a utilizable diameter of 125 mm as standard equipment Place the filter on the pan and close the lid Analyti
66. rial number Software version ID Dotted line Measurement series no Counting Reference sample quantity Counting Reference weight Counting result Counting result Dotted line Date time end of measurement Field for operator signature Blank line Dotted line 1SO GLP compliant printout for external calibration adjustment 17 Jan 2001 10 30 SARTORIUS AG Mod CP8201 Ser no 10105355 Ver no 00 13 01 ID 2690 923 Cal Ext Set 5000 0 g DAE 0 2 g Cal Ext Complete Diff 0 0 g 17 Jan 2001 10 32 Name 54 Dotted line Date time beginning of measurement Balance scale manufacturer Balance scale model Balance scale serial number Software version ID Dotted line Calibration adjustment mode Calibration weight Difference after calibration Confirmation of completed calibration Difference from nominal value after calibration Dotted line Date time end of measurement Field for operator signature Blank line Dotted line Data Interface Purpose Your balance scale is comes equipped with an interface port for connection to a computer or other peripheral device You can use an on line computer to change start and or monitor the functions of the balance scale and the application programs Features Type of interface Serial interface Operating mode Full duplex Standard RS 232 Transmission rates 150 300 600 1 200 2 400 4 800 9 600 19 200 baud Parity Mark space odd even C
67. rom 0 001 mg to 34 kg CP GP and GC models meet the highest requirements on the accuracy and reliability of weighing results through the following features Efficient filtering out of unfavorable ambient conditions such as vibration drafts etc Stable and reproducible weighing results Excellent readability under any lighting conditions Rugged durable weighing system These weighing instruments save work and speed up simple routine applications through these features Extremely fast response times Built in applications counting net total formulation animal weighing weighing in percent etc Total ease of operation 1SO GLP compliant recording capability for printouts Serial RS 232 port for optional connection toa PC Warnings and Safety Precautions The balance scale has been constructed in accordance with the European Directives as well as international regulations and standards for operation of electrical equipment electromagnetic compatibility and stipulated safety requirements Improper use or handling however can result in damage and or injury To prevent damage to the equipment please read these operating instructions carefully before using your balance scale Keep these instructions in a safe place Follow the instructions below to ensure safe and trouble free operation of your balance scale A Do not use this balance scale in a hazardous area location A If you use electrical
68. s package provides you with a series of important services which will guarantee you optimal results in working with your weighing instrument Installation Startup Inspection Training Initial verification EC Verification A Service Offered by Sartorius Our service technicians authorized to per form the verification of your weighing instruments that are acceptable for legal metrological verification can inspect and verify the metrological specifications at the place of installation within the Member States of the European Union and the Signa tories of the Agreement on the European Economic Area Subsequent Verifications within the European Countries The validity of the verification will become void in accordance with the national regula tions of the country in which the weighing instrument is used For information on verification and legal regulations currently applicable in your country and to obtain the names of the persons to contact please contact your local Sartorius office dealer or service center For more information on the verification of weighing instruments for use in legal metrology contact the Sartorius Service Center in accordance with the accreditation certificate received by Sartorius AG 85 86 Declaration of Conformity to Council Directives 89 336 EEC and 73 23 EEC The electronic precision weighing instrument of the series CP GP GC meets the requirements of
69. t press Store settings and exit menu Press and hold 2 sec 24 Print Current Settings At the 3rd menu level lowest level Press and hold C C Printout Example Menu 7 1 1 At the 2nd menu level Press and hold DD Printout Example Menu 7 1 Menu 7 2 1 Menu 7 3 1 All current menu settings are printed when the 1st menu level highest level is displayed Press and hold CQ C gt All current settings are printed Setting the Parameters Menu Codes Example Adapting the balance scale to very unstable ambient conditions menu code i 4 Step Key or instruction Display Printout 1 Turn off the balance scale 2 Turn on the balance scale and while all segments are displayed Scroll upward within a menu level after the last menu code the first code is displayed again 3 Select the second level scroll to the right 4 Select the third level scroll to the right 5 3 menu level Scroll until the desired number is shown nn 6 Confirm change o on display indicates active setting O Return to higher menu level from the 3 level O Set other codes as desired 7 Store settings and exit the menu or O Exit menu without storing changes gt Restart application gt lt gt briefly repeatedly QI QI repeatedly DD DD Press and hold 2 sec lt gt ABBA AB RO Re 70 S AUTOCAL KA RB am
70. t bit 1 or 2 stop bits Mark odd even or space 150 to 19 200 baud Software or hardware 69 Competence Series CP Series Model CP225D CP324S CP224S CP124S CP64 CP64 WDS Weighing capacity g 40 80 220 320 220 120 64 64 Readability mg 0 01 0 01 0 1 0 1 0 1 0 1 0 1 0 1 Tare range subtractive g 220 320 220 120 64 64 Repeatability std deviation lt mg 0 02 0 05 0 1 0 2 0 1 0 1 0 1 0 1 Linearity stmg 0 03 0 1 0 2 0 3 0 2 0 2 0 2 0 2 Response time average s lt 12 3 lt 3 lt 2 lt 2 lt 2 lt 2 Operating temperature range C 10 30 C 50 to 86 F Allowable ambient operating temperature C 5 40 C 41 F to 104 F Sensitivity drift within 10 30 C lt K 110 External calibration weight g 200 E2 200 200 E2 100 E2 50 E2 50 E2 of at least accuracy class 100 E2 Net weight approx kg 7 6 6 5 6 5 6 5 6 5 4 1 Pan size inner diameter mm 80 Pan surface cm 64 Weighing chamber height from pan to cover mm 232 232 232 232 232 Dimensions WxDxH mm 213x342x340 213x342x92 Electronics box WxDxH mm 134x51x155 5 2 AC power source Vw AC adapter 230 V or 115 V 15 20 Power requirements protection rating IP20 Frequency Hz 48 60 Power consumption average VA maximum 16 typical 8 Approx hours of operation with the YRBO8Z rechargeable battery pack h 20 22 22 22 22 22 Selectable weight uni
71. ta ID Codes The value currently displayed is printed weight or calculated value with unit Printout with Data ID Codes The current value displayed ID can be printed with a data N ID code of up to 6 characters T1 at the beginning of the line Ant Pre Print Application Parameters You can generate a print Comp out of one or more of the values configured for T COMP initialization of an appli nRef cation as soon as you initialize the balance scale wRef Wxx Auto Print You can have the weight N readout printed automatically Stat Stat Stat 52 1530 0 58 562 253 88 2 g ozt pcs 12345678 153 0 23 4 253 88 23 278 1 21 14 10 Zi 1200 0 153 0 Weight in grams Weight in Troy ounces Piece count Percentage Identification Current net weight Value in 2nd tare memory Piece count Percentage on ISO GLP records only Net total 7 compo nent weight Net total Total Counting Reference sample quantity Counting Reference weight Weighing in percent Reference weight Net weight Display blank Display underload Display overload ISO GLP compliant Printout Record Features You can have the parameters pertaining to the ambient weighing conditions printed before GLP header and after GLP footer the values of a weighing series These parameters include GLP header Date Time at beginning of measurement Balance scale man
72. the test standards listed below in conjunction with the associated power supplies auxiliary peripheral devices and installation equipment listed in Annex A2 see Annex Alfor a technical description and variants 1 Electromagnetic Compatibility 1 1 Source for 89 336 EEC EC Official Journal No 2000 C99 03 EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements Emission Residential areas Class B Immunity Industrial areas continuous unmonitored operation 2 Safety of Electrical Equipment 2 1 Source for 73 23 EEC EC Official Journal No 2000 C108 08 EN 61010 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements EN 60950 Safety of information technology equipment including electrical business equipment Sartorius AG 37070 Goettingen Germany 2001 eS ER Oz Het Med Dr G Maaz C Oldendorf Senior Vice President R amp D Senior Vice President R amp D Technical Operations Mechanical Electronic Engineering Engineering Mechatronics Division Mechatronics Division Declaration of Type Conformity to Directive No 90 384 EEC This declaration is valid for non automatic electromechanical weighing instruments for use in legal metrology These weighing instruments accepted for legal metrological verification have an EC Type Approval Certificate The model s concerned is are listed
73. ts Grams carats pounds ounces Troy ounces Hong Kong taels Singapore taels Taiwanese taels grains pennyweights milligrams parts per pound Chinese taels mommes Austrian carats tola baht and mesghal Built in interface Format Parity Transmission rates Handshake mode 2 70 RS 232 V24 V28 7 bit ASCII 1 start bit 1 or 2 stop bits Mark odd even or space 150 to 19 200 baud Software or hardware 2 Three sided weighing pan Diameter of inner circle Z The cross hatched section can be fully utilized Gem Series Model GC1603P GC803S GC803P GC2502 Weighing capacity ct 800 1 600 800 400 800 2 500 500 g Readability ct 0 001 0 01 0 001 0 001 0 01 0 01 Tare range subtractive ct 1 600 800 800 2 500 Repeatability std deviation lt ct 0 001 0 01 0 001 0 001 0 01 0 01 Linearity s ct 0 002 0 001 0 001 0 01 Response time average s lt 2 Operating temperature range C 10 30 C 50 F to 86 F Allowable ambient operating temperature RG 5 40 C 41 F to 104 F Sensitivity drift within 10 30 C lt K 1 10 110 1 10 2 10 External calibration weight g 200 100 E2 100 E2 200 F1 of at least accuracy class 100 E2 Net weight approx kg 6 1 Pan size inner diameter mm 80 80 80 110 Pan surface cm 64 64 64 120 Weighing chamber height from pan to cover mm 162 Dimensions WxDxH
74. ts regularly Remove the stainless steel weighing pan and thoroughly clean it separately Use a damp cloth or sponge to clean any stainless steel parts on the scale You can use any commercially available household cleaning agent that is suitable for use on stainless steel Clean stainless steel surfaces by wiping them down Then clean the weighing pan thoroughly making sure to remove all residues Use a damp cloth or sponge to wipe down any stainless steel parts on the scale again Afterwards allow the scale to dry If desired you can apply oil to the cleaned surfaces as additional protection A Do not use stainless steel cleaning agents that contain soda lye caustic acetic acid hydrochloric acid sulfuric acid or citric acid The use of scrubbing sponges made of steel wool is not permitted Solvents are permitted for use only on stainless steel parts Cleaning the Weighing Chamber and Draft Shield Open the draft shield cover and take out the removable parts Use a hand held vacuum cleaner and mini hose to remove any powdered sample material carefully Use blotting paper to remove any liquid sample material On models with a 3 sided draft shield pull the 3 draft shield walls upwards to remove if necessary Safety Inspection If there is any indication that safe operation of the balance scale with the AC adapter is no longer warranted Turn off the power and disconnect the equipment from AC power imme
75. uch the surface on which the balance scale rests on models with rectangular weighing pans only Leveling Balances Scales with a Weighing Capacity over 10 kg Adjust the leveling feet until the air bubble is centered within the circle of the level indicator Antitheft Locking Device on Balances Scales with a Weighing Capacity of up to 10 kg To fasten an antitheft locking device use the lug located on the rear panel of the balance scale Secure the balance scale at the place of installation e g with a chain or a lock Operating the Balance Scale Overview of Display and Operating Elements 15 14 13 12 11 10 9 BABBAHAA GN f mkglIb TARE TARE 06 5 AUTOCAL DA RE amp DYL GNET A i OQ E 3 Ze It a I 4 Wt N KW CaF Coat C FD Ola 6 8 Designation Description Designation Description 1 2 Weight units Tare function Press here to tare the weight of any container so that the readout shows the net weight of samples Symbol indicating that a GLP compliant printout is being generated Symbol indicating that a printout is being generated Symbol indicating data in memory when using the net total formulation program Data output function DID Press this key to send displayed values over the built in data interface to a DataPrint printer or a PC Function key Starts an application program Symbol indi
76. ufacturer Balance scale model Balance scale serial number Software version number Identification number of the current sampling operation GLP footer Date Time at end of measurement Field for operator signature The record is output to a Sartorius data printer or a computer Settings Set the following menu codes see Configuring the Balance Scale 1SO GLP compliant record after calibration adjustment only menu code amp or 1SO GLP compliant record always on menu code 8 ia Line format for printout With data ID codes 22 characters menu code 722 Z No 1SO GLP compliant record is output if any of the following settings are configured menu codes 5 4 5 15 56 5 automatic printout and 12 i Function Keys Press CQ C gt to output header and first measured value Header is output the first time CQ gt C is pressed To output header and reference data automatically with an application program active Press End an application 1 Output GLP footer Press cr gt 2 End application program Press cr gt 53 The ISO GLP compliant record can contain the following lines 17 Jan 2001 10 15 SARTORIUS AG Mod cP8201 Ser no 10105355 Ver no 00 13 01 ID 2690 923 L ID nRef 10 pcs wRef 21 14 g Qnt 235 pcs Ant 567 pcs 17 Jan 2001 10 20 Name Dotted line Date time beginning of measurement Balance scale manufacturer Balance scale model Balance scale se
77. y unstable conditions Block keys C D key print auto print activate or block Release keys Restart Self test key Internal calibration adjustment Nu so zZr r Command character Format 2 Meaning fo Function key CF gt fl Function key s3 CD key x0 Perform internal calibration x1 Print balance scale model x2 Print weighing cell serial number for models with built in motorized calibration weight only 59 Synchronization During data communication between the balance scale and an on line device computer messages consisting of ASCII characters are transmitted via the interface For error free data communi cation the parameters for baud rate par ity handshake mode and character for mat must be the same for both units You can set these parameters in the Setup menu so that they match those of the on line device You can also define parameters in the balance scale to make data output dependent on various conditions The conditions that can be configured are described under each of the application program descriptions lf you do not plug a peripheral device into the balance scale interface port this will not generate an error message 60 Handshake The balance scale interface Sartorius Balance Interface SBI has transmit and receive buffers You can define the handshake parameter in the Setup menu Hardware handshake CTS DTR Software