Home
GB-PAC-08E4 Manual 11112011
Contents
1. kit and exhaust hose must be installed When the unit is operating in fan mode the window kit and exhaust hose do not need to be installed MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches e Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise e Mount the exhaust hose onto the back of the unit by locking the hose adapters into place e For maximum efficiency do not bend the hose as much as possible SINGLE HOSE WINDOW KIT INSTALLATION Installation of the Venting Kit Innovative products for a cleaner more comfortable world FOR SINGLE HOSE PORTABLE AIR CONDITIONERS When installing the exhaust hose try and keep it as flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 This installation is OK The venting kit must be installed in order for the unit to work correctly in the air conditioning mode The venting kit should not be used while the unit is heating or fanning The window kit has been designed to fit into most vertical and horizontal window openings The window kit can also be used in a sliding door 1 Choose a suitable location near a grounded electric
2. 3 Attach the Drain Hose to the Drain Port using the Drain Hose Clip Insert the Drain Plug into the free end of the Drain Hose and guide the Drain Hose through the Clamp Once finished the unit can be easily drained by removing the drain plug and guiding the drain hose into a small pan to drain the water A Drain Plug D Drain Hose Clip B Drain Port E Clamp C Drain Hose 11 E MAINTENANCE Note Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clean or replace filter If the air filter is blocked with a dust the airflow volume may reduce Itis recommended to clean the filter once every two weeks or as needed 1 Remove the filter from the filter compartment on the back of the unit 2 Wash the air filter by immersing it gently into warm water with a neutral detergent Rinse the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the watranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the water drainage s
3. SOLEUSA ID Powered by GREE Model GB PAC 08E4 8 000 BTU Portable Air Conditioner Operating Instructions Powered by Thank you for choosing Soleus Air Powered by Gree Portable Air Conditioner This owner s man ual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit E IMPORTANT INSTRUCTIONS Before installing and using your portable air conditioner please read this owner s manual carefully Store this manual in a Safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the unit by inserting or pulling out the power plug 6 Do not use an adapter plug or extension cord 7 Do not use the unit in the immediate su
4. al outlet and a suitable window or door Remove packaging and locate components figure a 2 Slide the exhaust connector over the discharge opening on the back of the unit figure b 3 Connect the exhaust hose to the exhaust connector aligning the fitted grove figure c 4 Open the window or door and adjust the length of the window kit to fit the opening figure d If necessary mark the kit and cut one end down to properly fit the opening figures e amp f 5 Attach the window kit adapter to the window kit figure g 6 Place the window kit back into the window and attach the exhaust hose to the window kit adapter figures h amp i Close the window tightly figure j Your Portable Air Conditioner is now ready to cool NOTE When using the venting system keep the exhaust hose as straight as possible The exhaust hose can be shortened but it is not recommended to increase the length of the exhaust hose Do not use an extension cord with your portable air conditioner The is a poor installation angles like the pictures above Multiple bends will decrease performance and efficiency CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS CONTROL PANEL amp LED DISPLAY BUCKET FULL LIGHT COOL MODE LIGHT DRY MODE LIGHT REMOTE RECEIVER LED DISPLAY FAN MODE LIGHT ae MODE ON OFF 7 MODE BUTTON 1 TEMP SELECT BUTTON L POWER BUTTON CONTROL PANEL OPERATING INSTRUCTIONS 1 Power On and Of
5. f Press the POWER button once to manually turn the unit on Press the POWER button once more to turn the unit off 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Cool Dry and Fan only mode Each press of the MODE button will light up a different icon on the control panel The exhaust hose and window kit must be installed when the unit is in cool or dry mode When using the unit as a fan it is not necessary to keep the exhaust hose and window kit connected to the unit 3 Temperature Select the desired temperature by pressing either or key when using the unit in cooling mode The digital thermostat will display the set temperature 4 Louver Direction This unit has 4 Way directional louvers Use the louver guides to direct air where cooling or fanning 15 needed most Bucket Full When the unit cannot evaporate the collected moisture fast enough The excess water will collect in a backup water tank located inside the unit The bucket full icon will light up 1f this occurs ee REMOTE CONTROL OPERATING INSTRUCTIONS T 0H ALTO COOL NOTE Heat mode is not available a on the GB PAC 08E4 SHING LCD DISPLAY and rA MODE LABELS SPEED POWER BUTTON MODE BUTTON MODE TEMP SELECT BUTTONS FAN BUTTON FAN SWING BUTTON Not Available GB PAC 08E4 SLEEP BUTTON SLEEP TIMER TIMER BUTTON 1 Power On and Off Press
6. limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support amp Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 20035 E Walnut Dr North City of Industry CA 91789 USA www soleusair com 15 66129906767
7. omatically fan the room to circulate air When the room temperature is between 68 F 73 F the air conditioner will operate in Fan mode if it was previously selected or dehumidifier mode 1f another mode was used previously to remove humidity from the air as well as some cooling to help lower the room temperature When the room temperature is between 74 F 79 F the air conditioner will always operate in dehumidifier mode When the room temperature rises above 79 F the unit will operate in air conditioner mode to maximize cooling Auto mode uses pre determined settings to keep you comfortable by choosing the most energy efficient mode based on the temperature of the room DRAINING COLLECTED WATER When the temperature or humidity is too high the air conditioner may not be able to evaporate all of the water as quickly as needed All moisture that is unable to be evaporated is placed in a small bank up water tank 1 side the unit When this tank is completely full an alarm will sound the compressor will shut off and the bucket full icon will light up on the control panel To manually empty the tank please follow the instructions below ir f i AA i 1 Drain Hose Drain Hose Clip Drain Plug 1 Remove the pre installed Drain Cap from the unit See Below 2 Attach the Clamp with the provided Screw See Below A Drain Port A Drain Port B Drain Cap B Clamp
8. ontrol may not be e Lower the set thermostat tempera set correctly ture The air filter is dirty e Clean the filter See the Cleaning and Care Section of the manual The room may be too warm e Please allow time for the room to cool down after turning on the air conditioner Cold air is escaping e Check for open furnace registers and cold air returns The Evaporator is frozen The unit is defrosting and will re operation when done The Remote Control is not working The batteries are inserted incorrectly Check the position of the batteries The batteries may be dead e Replace the batteries 13 TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The LCD Display is showing E5 Low Voltage Protection Unplug for 10 minutes and then turn on the unit If E5 is still dis played contact customer service The LCD Display is showing H8 The backup water tank is full Drain the water tank If the H8 I still displayed after the water tank has been emptied con tact customer service 14 220 00 WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal u
9. power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If a test is performed and the indicator light remains ON current leakage has been detected Do not use the air conditioner or attempt to reset the LCDI Plug Contact Soleus Air Powered by Gree Customer Service for trou bleshooting recommendations WARNING 1 DO NOT press the TEST button while the air conditioner is operating 2 The TEST and RESET buttons should not be used as ON and OFF switches 3 The cord and plug are not intended to offer protection to externally connected loads or supply circuits 4 The and plug are intended for indoor use only PRODUCT DIAGRAM Control Panel a al TI Louver Guides 7 MERANA Louvers ane es lee in tee ss Remote Control Holder Cs Power Cord ajr EN A N WMA ANA Filters I ii gt Upper Air Intake Air Exhaust gt Lower Air Intake i 1 fs NN ca Fa 222 PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose 1 Exha
10. r is off it be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting To set the Auto on Timer press the TIMER button on the unit or remote control Each touch of the buttons on the remote will change the timer setting in 30 minute increments 5 hours The T ON and H lights will blink while the Auto on Timer is being set Once the timer is set press the TIMER button once more to save the setting Press the ON OFF button to cancel the timer Auto off Timer When the air conditioner is on it can be set to automatically turn off in 30 minutes to 24 hours To set the Auto off Timer press the TIMER button on the remote control Each touch of the buttons on the remote will change the timer setting in 30 minute 5 hour intervals The T OFF and H lights will blink while setting To cancel the timer press the ON OFF button Once the timer is set press the TIMER button once more to save the setting Press the ON OFF button to cancel the timer 6 Sleep Mode Press the SLEEP mode button to engage SLEEP mode Sleep mode automatically reduces the set temperature by 2 F after one hour and 4 F after two hours This feature limits compressor usage and enhances energy savings while you are sleeping 7 Auto Mode When AUTO mode is selected the air conditioner will automatically choose the operating mode base on the current room temperature When the room is below 68 F the air conditioner will aut
11. rroundings of a bath a shower or a swimming pool 8 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual 9 Do not let children play near this unit 10 Always inspect the cord for signs of damage before use If the power cord is damaged it must be replaced by the manufacturer or a qualified service technician 11 When cleaning the unit always turn the unit off and unplug the power cord LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI Leakage Current Detection and Interruption power cord and plug as required by US National Electric Code 440 65 This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side The LCDI power cord and plug will remove the supply source via electrical disconnect circuit trip if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value The cord will remain de energized until the devise has been manually reset This is intended to reduce the risk of a fire in the power cord or combustible materials nearby The cord shields are not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug
12. se Soleus International Inc will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As a condition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc e Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some states do not allow the
13. the ON OFF POWER button once to manually turn the unit on Press the Power button once more to turn the unit off When you manually power the unit on and off by pressing the ON OFF button the preset timer will be cancelled 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto Cool Dry and Fan only mode Once a mode is selected an arrow will light up on the LCD display next to the selected MODE label on the remote Auto mode automatically chooses the air conditioner dehumidifier or fan mode based on the current room temperature AUTO COOL DRY NOTE HEAT MODE NOT AVAILABLE HEAT lt FAN 3 Fan Speed Press the FAN speed button to cycle through low medium and high fan speeds The small fan icons will light up depending on which speed is selected The more fan icons light up the higher the speed The fan icons are located on the LCD display next to the SPEED label auto d gl 4 Fani 4 Fan2 dil Fan3 4 Temperature Setting When the unit is in Air Conditioner mode you can select your desired temperature Press the TEMP SELECT buttons or to select your desired temperature setting The temperature on the LCD display on the remote control will increase or decrease accordingly Hold the buttons for two seconds to rapidly increase or decrease the temperature REMOTE CONTROL OPERATING INSTRUCTIONS Cont 5 Auto on Timer When the air conditione
14. top in the back of the unit located at the bottom 2 Unplug the unit 3 The unit should be stored in a cool dry place DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN CE TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The air conditioner is unplugged or not e sure the air conditioner plug connected well is pushed completely into the out let The Air Conditioner will not start Check the house fuse circuit The fuse is blown circuit breaker is breaker box and replace the fuse tripped or reset the breaker e The unit will automatically re start Power Failure when power is restored There is a protective time delay approx 3 minutes to prevent tripping of the compressor overload For this reason the unit may not start normal cooling for 3 minutes after it is turned back on e Press the RESET button located The current interrupter device is on the power cord plug tripped Ifthe RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Airflow is restricted e Make sure there are no curtains blinds or furniture blocking the front of the air conditioner The Air Conditioner does not cool as should The temperature c
15. ust Hose Adapter 1 Window Kit Adapter 1 Hose Adapter 1 Remote Control amp AAA Batteries 2 batteries Window Kit 3 Sliding Panels 1 single hose panel 2 extension panels Drain Hose Assembly drain pipe clamp hose clip rubber plug amp screw Owner s Manual SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 86 F WB 78 F Noise level is measured at a distance of 3 28 ft away from the front of the unit when the unit is in cooling mode e Power consumption is measured when the fan runs at the highest speed setting e These specifications are for reference only For actual data please refer to the rating label on the back of the unit e If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature the air conditioner may not work properly OO Dimensions W x H x D Package Dimensions W x x D eee PARTS amp WINDOW KIT ASSEMBLY PARTS EXHAUST HOSE amp ADAPTERS Exhaust Hose Adapter Exhaust Hose Wood Screws 4 TTT TMT Nf PETE LL 7 11 Piet ty I TERRI fee Hose Adapter Adjustable Window Slider 3 8 2 ASSEMBLY amp INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier the window
Download Pdf Manuals
Related Search
Related Contents
MOPSIC – An Extended Version of MOPSI Kanex AirBlue Lpta410 GB-NL-FR-ES-D Pince B102 BenQ S52 Laptop User Manual TS-590S USB Audio Setting Manual Origin Storage 80GB 5400RPM Notebook Drive Notice constructeur Dépliant Multitud` Le plan Copyright © All rights reserved.
Failed to retrieve file