Home

User Manual

image

Contents

1. 8 Kanal Send Return Snake Sag _ Blelslelelelelels lalalalala e d bech Ah Sd E v v S Dn GE Dn KEN d aaa a ei e E MULT TRACK RECORDING Mischpult 8 Kanal Send 818 T amp 16T amp 8 87 amp J Ces Jeleleelelelelelle EE j 8 gt 5 8611816161816 1616161616161616 8 Kanal Send Return Snake v a Multi Track PC Rekorder Soundkarte Multi Track Monitoring F r Multi Track Abh rzwecke k nnen Sie den MZD 88 zwischen den Ausg ngen einer Soundkarte oder eines Multi Track Rekorders und den Eing ngen eines Mischpults anschlie en Sie erhalten so zus tzlich vier separate Mixe ohne den Signalfluss zum Mischpult zu beeintr chtigen 11 20 Multi Track Recording Ebenso besteht die M glichkeit den MZD 88 in die Insert Wege eines Mischpults einzuschleifen 00033027 DOC Version 1 0 9 REINIGUNG UND WARTUNG LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden Im Ger teinneren befinden sich au er der Sicherung keine zu wartenden Teile Wartungs und Service arbeiten sind ausschlie lich dem autorisierten Fachhandel vorbe
2. Je Ee Outputs Inputs sr sr 8 channel Send Return Snake sao COOC a e o leleieog H SE SEW ai AAL f ZS B Hlelelelelelelele lalelelelalelela _ v Uy In SP Y Ur sih J hi BMULTITRACK RECORDING Mixer 8 channel Send Return Snake m Multitrack Pi Recorder Soundcard Multitrack monitoring Use the MZD 88 s input connectors to insert it between the eight outputs of a multitrack recorder or a soundcard and the line inputs of another mixing console You can mix the outputs to four individual stereo cue mixes without interrupting the signal flow ot the mixing console 19 20 Multitrack recording You can also insert the MZD 88 into the insert paths of a mixing console 00033027 DOC Version 1 0 9 CLEANING AND MAINTENANCE DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a soft lint free and moistened cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the fuse Maintenance and service operations are only to be carried out by authorized dealers 9 1 Replacing the fuse If the fine wire fuse of the device fuses only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure Step 1 Open the fuseholder on the rear panel wit
3. OMNITRONIC BEDIENUNGSANLEITUNG USER MANUAL MZD 88 MATRIX ZONE DISTRIBUTOR Inhaltsverzeichnis Table of contents 1 EINFUHRUNG EE 4 2 SICHERHEITSHINWEISE viseecesccescccevessecrantecssacteaecetsvieecsete na ee san ann ann nal dehnen nad 4 3 BESTIMMUNGSGEM SSE VERWENDUNG ursususnsnnsnsnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennn 6 4 GER TEBESCHREIBUNG uuuuuussssnsnnnsnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnsnnnnnnnnnnnnnnnenn 7 6 INSTALLATION EE 8 e TT EN 9 Bs EDIE NUING EE 10 9 REINIGUNG UND WARTUNG uuzssusnnannennnnnnannnnnnnnnnnnnnnnannnnnannnnannnnnnnnnannnnnnannnnnnnnnnnnnnnsnnnnnnnnnnnnnnnannnnnannnnn 12 10 TECHNISCHE DAT EN PERRERERDERREPEORRRE RERBEREROLHFESPEREHECHETIERTE BEARRFES ER HEIFEESUHEEEEERERESSEHEKREFECEOFFFREESTEREFPENSTEEREFFEFEER 12 1 INTRODUCTION E 13 2 SAFETY INST RUG TIONS ees Eege See EE EE EES EES 13 3 OPERATING DETERMINATIONS u 4240444002040000nn0nnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnannnnnnnnnnsnnnnannnnnnnnnnnnnnnnennn nn 15 A DESCRIPTION ees eebe ge SEELEN 15 6 INSTALLATION 2 4 42244202202004240020 ee EEN EENS ann en u iene aaa ernten 17 Ts ei ei Il e tel FE 17 B OPERATION 2 ssiaieesesee eege EENS kann Dad tv Eaa EEEE aa PEPEES AEEA a AAO eaa anna aaa ER CAE 18 9 CLEANING AND MAINTENANCE uuussusnnsnnnnannnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnannnnnnnnnnnnnnnnannnnnsnnnnannnnnnnnnnsn
4. PAN Regler um das Signal zwischen dem linken und rechten Ausgang zu balancieren 10 20 00033027 DOC Version 1 0 Mit dem MZD S8 k nnen Sie jedes Standard Mischpult um acht zus tzliche Aux Wege erweitern um Stereo und Mono Mixe f r verschiedenste Anwendungen z B B hnen Monitoring Multi Track Aufnahmen und Monitoring Effektwege Zonen und Matrix Konfigurationen zu erstellen 8 1 Anwendungsbeispiele E PERSONAL MONITORING H annnnnnn eeeeeee gt e System drahtloses System Zone A E PERSONAL MONITORING v ZoneB rm Zonea 6 ZoneC w ZoneD w vy Vv v Vv Vv Vv Vv Vv Monitoring Mit dem MZD 88 haben Sie die M glichkeit separate Mixe fur Sanger oder Musiker bei Live Auftritten oder Studioaufnahmen zu erstellen ohne das bestehende Setup Ihres Mischpults neu zu konfigurieren und aufwendig zu verkabeln Lautsprecher Monitoring Mischpulte verf gen oft nicht ber genug Ausg nge f r Monitoring Zwecke Selbst wenn jedes Bandmitglied seinen eignen Monitor Lautsprecher hat m chte es zuatzlich auch seinen eigenen Mix h ren Mit dem MZD 88 k nnen Sie f r jedes Bandmitglied einen separaten Mix erstellen ganz gleich wie unterschiedlich jeder Mix sein muss E MULT TRACK MONITORING Mult Track Rekorder PC Soundkarte Mischpult
5. Use the PAN control to balance the signal between the left and right output 18 20 00033027 DOC Version 1 0 The MZD 88 extends the capabilities of a standard mixing console by providing eight additional auxiliary sends use it to create stereo or mono mixes for a variety of applications e g for personal and loudspeaker monitoring mulitrack recording and monitoring stereo effect sends zone mixing and matrix mixing 8 1 Application examples E PERSONAL MONITORING 00000000 ILILILILIL wired system wireless system E PERSONAL MONITORING Si In ZoneD mm ZoneC ZoneB ml ZoneA 6 ch er e sy SR SS H Bs i ea Wi eu Vd D Zone D it o l Monitoring Loudspeaker monitoring The MZD 88 gives you the possibility to create personal mixes for vocalists or instrumentalists for live and studio applications without having to reconfigure the existing setup of a mixing console Mixing consoles often do not provide enough dedicated outputs for monitoring applications Even if each performer has its own speaker cabinet he does not get his own mix With the MZD 88 you can provide those individual mixes for each band member regardless how different each mix needs to be BMULTITRACK MONITORING Multitrack p Recorder Soundcard
6. damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose that also a minimal amount of liquid may have entered the device it must immediately be disconnected This is also valid if the device was exposed to high humidity Also if the device is still running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the device Thi
7. dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Grifflache an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker besch digt werden was zu t dlichen Stromschl gen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbrochen werden und das Ger t mit einem trockenen Tuch gereinigt werden Staub kann die Isolation reduzieren was zu t dlichen Stromschl gen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden Es d rfen unter keinen Umst nden Fl ssigkeiten aller Art in Steckdosen Steckverbindungen oder in irgendwelche Ger te ffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Ger t eingedrungen sein
8. 2 HE Der MZD 88 ist f r den professionellen Anwendungsbereich vorgesehen Die Anschl sse befinden sich auf der R ckseite des Ger tes die Bedienelemente befinden sich auf der Frontseite Das Ger t besitzt vier Beschallungszonen mit je acht identischen Kan len FRONTSEITE Netzschalter PAN Regler Betriebsanzeige LEVEL Regler ZONE 1 S COOC 000 0080900808 S D 0 000 O SE A N a NETZSCHALTER Dr cken Sie den Netzschalter um das Ger t ein und auszuschalten Die Betriebsanzeige POWER LED zeigt den eingeschalteten Zustand des MZD 88 an a POWER LED Betriebsanzeige des MZD 88 LEVEL REGLER Mit den LEVEL Reglern legen Sie f r die jeweilige Eingangsquelle den Pegel an dem entsprechenden Stereo Ausgang auf der R ckseite fest Drehen Sie den Regler im Uhrzeigersinn um den Pegel ab der Mittelrastung um bis zu 12 dB zu erh hen 7 20 a PAN REGLER Mit den PAN Reglern bestimmen Sie f r die jeweilige Eingangsquelle den Signalanteil am linken und rechten Ausgang der entsprechenden Zone In der Mittelstellung erhalten beide Ausg nge den gleichen Signalpegel 00033027 DOC Version 1 0 RUCKSEITE Eing nge Spanngungswahlschalter D Zonen Ausg nge Netzanschluss E MZD 88 a Eing nge XLR Eingangsbuchsen sym f r den Anschluss von Audio Ger ten mi
9. clockwise beyond the detented position to increase the level up to 12 dB m PAN control Positions the input signal between the left and right output of the respective zone In mid position the signal level is equal at both outputs Voltage selector Make sure this switch is properly set AC input with fuseholder Used to plug the supplied power cord in Only replace the fuse when the device is disconnected from mains Only REAR PANEL INPUT section Voltage selector 00000000 00000000 OUTPUT sections AC input E MZD 88 Inputs XLR inputs bal for connecting audio units units with line level outputs Zone outputs Each zone disposes of a stereo output 2 x XLR bal for left and right The PAN control directs the signal to the respective output outputs STEREO A for PA zone 1 outputs STEREO B for PA zone 2 outputs STEREO C for PA zone 3 outputs STEREO D for PA zone 4 16 20 m PAN control Positions the input signal between the left and right output of the respective zone Voltage selector Make sure this switch is properly set AC input with fuseholder Used to plug the supplied power cord in The correct fuse value is specified on the rear panel 00033027 DOC Version 1 0 6 INSTALLATION This device is built for 19 racks 483 mm This rack should be a double door rack where you can open the front panel and the rear panel The rack should be provide
10. d with a cooling fan When mounting the device into the rack please make sure that there is enough space around the device so that the heated air can be passed on Steady overheating will damage your device You can fix the device with four screws M6 in the rack If several devices are to be installed make sure that you leave 1 unit space between the devices 7 CONNECTIONS t All connections have to be made or changed only if the mixer and all audio devices connected to it is are switched off 1 Connect the outputs of the audio sources to the input jacks 2 A PA amplifier for speakers mixers or a subsequent unit with line level can be connected to the XLR connectors OUTPUT Balanced use with XLR connectors 1 Ground Shield 1 2 Hot Gei 3 Cold on Output For unbalanced use pin 1 and pin 3 have to be bridged 7 1 Connection with the mains Connect the device to the mains with the enclosed power supply cable The occupation of the connection cables is as follows Cable Pin __ International L fee Blue Neutral ja e The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation The device must only be connected with an electric installation carried out in compliance with the IEC standards T
11. e die Originalverpackung um Transportsch den zu vermeiden Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag etc verbunden 6 20 00033027 DOC Version 1 0 4 GERATEBESCHREIBUNG 8 Kanal Audio Mischer Der OMNITRONIC MZD 88 ist ein Audiomischpult mit Matrixsystem das ultra flexible Konfigurationsm glichkeiten erlaubt Er verf gt ber 8 Eing nge die den 8 Ausg ngen beliebig zugeordnet werden k nnen Die Ausg nge des Mixers sind in 4 Gruppen unterteilt So kann z B das Stereo Ausgangsignal von 4 verschiedenen Eingangsquellen an 4 Beschallungszonen geroutet werden ohne das eine aufwendige Neuverkabelung des MZD 88 zuvor erfolgen muss Ebenso m glich sind 8 unterschiedliche Ausgangsignale da jeder Eingang einen eigenen Pegel und Pan Regler besitzt e Matrix Eingangszuordnung 8 Eingangsquellen k nnen allen 8 Ausg ngen frei zugeordnet werden e Unterteilung der 8 Ausg nge in 4 Gruppen jede mit separaten Pegel und Pan Reglern pro Kanal e Ultra flexible Konfigurationsm glichkeiten verteilt das Signal von max 8 Audioquellen auf z B 8 Mono zonen oder 4 Stereozonen jeweils mit unterschiedlichem Ausgangssignal e Ein und Ausg nge ber symmetrische XLR Buchsen Frequenzbereich 20 20 000 Hz e 19 Ma e f r Rackeinbau
12. er Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung 4 20 00033027 DOC Version 1 0 Der Aufbau entspricht der Schutzklasse Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung des Ger tes und zu t dlichen Stromschl gen f hren Den Netzstecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei eingesetzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zur Folge haben Netzleitungen nicht ver ndern knicken mechanisch belasten durch Druck belasten ziehen erhitzen und nicht in die N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausreichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf
13. etzschalter auf OFF steht Bevor die Verbindungen hergestellt werden m ssen alle Ger te ausgeschaltet sein 1 Schlie en Sie die Ausg nge der Audioquellen an die Eingangsbuchsen INPUT an 2 _ Endverst rker f r Lautsprecher Mischpulte oder andere nachfolgende Ger te mit Line Pegel k nnen die XLR Buchsen OUTPUT angeschlossen werden Symmetrische XLR Verbindung 1 Masse Schirm 1 2 Plus Phase 3 Minus Phase von Eingang Ausgang Um eine XLR Verbindung unsymmetrisch an zu schlie en m ssen Pin 1 und 3 gebr ckt werden 7 1 Anschluss ans Netz Schlie en Sie das Ger t ber die beiliegende Netzanschlussleitung ans Netz an Die Belegung der Anschlussleitungen ist wie folgt Leitung Im international Au enleiter L _ Blau Neutralleiter Gelb Gr n Schutzleiter zZ Der Schutzleiter muss unbedingt angeschlossen werden Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden Das Ger t darf nur an eine Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein 9 20 00033027 DOC Version 1 0 8 BEDIENUNG 1 Belassen Sie alle LEVEL Regler in der Mittelstell
14. g console for mixing different audio signals This product is allowed to be operated with an alternating current of 115 230 V 50 60 Hz and was designed for indoor use only This device is designed for mobile use and for permanent installations By operating amplifying systems you can produce excessive sound pressure levels that may lead to permanent hearing loss Please refer to the explanations under Legal instructions Please note operating an amplification system in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part The operator must therefore inform himself on the current safety instructions and consider them Do not shake the device Avoid brute force when installing or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others This device must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The ambient temperature must always be between 5 C and 45 C Keep away fro
15. ge your device Leave the device switched off until it has reached room temperature 13 20 00033027 DOC Version 1 0 Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer This device falls under protection class The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destruction of the device and to mortal electrical shock Always plug in the power plug least The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or
16. h a fitting screwdriver Step 2 Remove the old fuse from the fuseholder Step 3 Install the new fuse in the fuseholder Step 4 Replace the fuseholder in the housing Should you need any spare parts please use genuine parts If the power supply cable of this device becomes damaged it has to be replaced by a special power supply cable available at your dealer Should you have further questions please contact your dealer 10 TECHNICAL SPECIFICATIONS Power supply 115 230 V 50 60 Hz Input impedance 10 KQ Weight 3 5 kg Please note Every information is subject to change without prior notice 14 07 2011 20 20 00033027 DOC Version 1 0
17. halten 9 1 Sicherungswechsel Wenn die Feinsicherung des Ger tes defekt ist darf diese nur durch eine Sicherung gleichen Typs ersetzt werden Vor dem Sicherungswechsel ist das Ger t allpolig von der Netzspannung zu trennen Netzstecker ziehen Vorgehensweise Schritt 1 ffnen Sie den Sicherungshalter an der Ger ter ckseite mit einem passenden Schrauben dreher Schritt 2 Entfernen Sie die defekte Sicherung aus dem Sicherungshalter Schritt 3 Setzen Sie die neue Sicherung in den Sicherungshalter ein Schritt 4 Setzen Sie den Sicherungshalter wieder im Geh use ein Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Ger tes besch digt wird muss sie durch eine besondere Anschluss leitung ersetzt werden die von Ihrem Fachh ndler erh ltlich ist Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung 10 TECHNISCHE DATEN Max Eingangspegel Ma e BxTxH 482 x 195x 89 mm 3 5 kg Bitte beachten Sie Technische nderungen ohne vorherige Ank ndigung und Irrtum vorbehalten 14 07 2011 12 20 00033027 DOC Version 1 0 English USER MANUAL OMNITRONIC MZD 88 Matrix Zone Distributor CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing For your own safety please read this user manual carefully before you initially start up E
18. he electric installation must be equipped with a Residual Current Device RCD with a maximum fault current of 30 mA 17 20 00033027 DOC Version 1 0 8 OPERATION 1 Prior to switching on set all LEVEL controls to mid position to avoid damage to the hearing by a volume which is too high when switching on 2 Switch on the device via the power switch The power indicator on the front panel lights up Switch on the connected units always switch on your PA amplifier last 3 Adjust the desired volume ratio with the Level controls 4 Determine the balance of the input signal between the left and right output 5 Switch off the unit with the POWER switch after operation OPERATION Row CH 1 Zone A Zone B Zone C Zone D Geeeeeee Stereo outputs or mono outputs 1 8 MZD 88 ts The figure shows the signal of CH 1 routed to each pair of stereo outputs To add signal from the CH 2 input to the STEREO A outputs use the level controls in the same zone STEREO A OUT 1 2 in the second row CH 2 Create stereo mixes with the LEVEL and PAN controls on the front panel of the MZD 88 Each row on the front panel e g CH 1 corresponds to one input Each zone on the front panel e g STEREO A OUT 1 2 corresponds to a pair of stereo outputs Use the the LEVEL control to add signal to each pair of stereo outputs
19. k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einen Fachmann berpr ft werden ob durch den Fl ssigkeitseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Stromschl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben Bevor das Ger t eingeschaltet wird m ssen alle Fader und Lautst rkeregler auf Null bzw auf Minimum gestellt werden ACHTUNG Endstufen immer zuletzt einschalten und zuerst ausschalten Kinder und Laien vom Ger t fern halten GESUNDHEITSRISIKO Beim Betreiben einer Beschallungsanlage lassen sich Lautst rkepegel erzeugen die zu irrepa rablen Geh rsch den f hren k nnen Im Ger teinneren befinden sich keine zu wartenden Teile Eventuelle Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten 5 20 00033027 DOC Version 1 0 3 BESTIMMUNGSGEMASSE VERWENDUNG Bei diesem Gerat handelt es sich um ein professionelles Mischpul
20. m direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN The ambient contamination must never exceed level 1 and must not be conducting only dry Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Never remove the serial barcode from the device as this would make the guarantee void Please consider that unauthorized modifications on the speaker system are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock hearing loss etc 4 DESCRIPTION 8 channel audio mixer The OMNITRONIC MZD 88 is an audio mixer with matrix system of 8 input and 8 outputs which allows for multiple output configurations and inputs
21. mixing The 8 outputs are divided in 4 groups Thus it s possible to supply 4 different PA zones with a stereo output by routing different input signals to these zones without having to change the cable configuration It s also possible to obtain 8 outputs with different mixing as every input has its own level and PAN controls e Matrix input assignment 8 audio inputs are freely assignable to each of the 8 outputs Division of the 8 outputs into 4 groups each with separate level and pan control per channel e Ultra flexible configuration modes distributes the signal of up to 8 audio sources to e g 8 mono zones or 4 stereo zones each with a different output signal Inputs and outputs via balanced XLR jacks Frequency range 20 20 000 Hz 19 dimensions for rack installation 2 U 15 20 00033027 DOC Version 1 0 The IMZD 88 is designed for professional application The connectors are located on the rear panel the operating elements are on the front panel The unit features four PA zones with eight identical channels each FRONT PANEL POWER LED LEVEL control Power on off PAN control E MZD 88 Power on off Press this button to turn the MZD 88 on and off a POWER LED The power indicator lights up when the MZD 88 is powered on u LEVEL control For adjusting the input level at the respective stereo output at the rear panel Turn the control
22. nnnnannnnn 19 10 TECHNICAL SPECIFICATIONS 42 2 45524 424454 004404 4aa been are anna Bere nennen ine 20 Diese Bedienungsanleitung gilt f r die Artikelnummer 10304120 This user manual is valid for the article number 10304120 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www omnitronic com 2 20 00033027 DOC Version 1 0 ZH 09 0S A OE2 SII LNdNI IV Asll AOE2 WOS 2UO 31110 mmmM SINOELINING e VNOILNVD Y ANNE Lane LN WAINDIMOHS DINOHLINWO xkO U Aose vS03 NSH 3505 A0S2 VSO3 A OE2 Send MS uogdunsuo gt smod 2H 09 05 Dv A 0E2 Si med vmog 88 QZW DINOYLINNO zt RELENE 3 03431S 3S LNdNI a 034315 ZAINdNI 8 2 1N0 Q 03431S u 4 m EI m o a o S y a CO 23431 2343 11N0 V 034315 ve 1N0 8 034315 IINOHLINNWO CH 00033027 DOC Version 1 0 3 20 Deutsch BEDIENUNGSANLEITUNG OMNITRONIC MZD 88 Matrix Zonen Verteiler ACHTUNG Ger t vor Feuchtigkeit und N sse sch tzen Vor Offnen des Ger tes vom Netz trennen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleit
23. s is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the device the device must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries The device and all connections have to be lightning protected Never install the powered mixer next to highly sensitive devices like pre amplifiers or tape decks as the strong magnetic field of the integrated amplifier can produce hum in these devices The magnetic field is strongest directly above or below the power mixer Only connect the device when the power switch is off Never connect the inputs or outputs to any power source batteries etc Never connect output to output Before the device is switched on all volume controls have to be set to zero or minimum position CAUTION Turn the amplifier on last and off first Please note that damages caused by manual modifications on the device or unauthorized operation by unqualified persons are not subject to warranty Keep away children and amateurs HEALTH HAZARD By operating an amplifying system you can produce excessive sound pressure levels that may lead to permanent hearing loss There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers 14 20 00033027 DOC Version 1 0 3 OPERATING DETERMINATIONS This device is a professional mixin
24. t mit dem sich Audiosignale von verschiedenen Quellen mischen lassen Dieses Produkt ist fur den Anschluss an 115 230 V 50 60 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Vermeiden Sie Ersch tterungen und jegliche Gewaltanwendung bei der Installierung oder Inbetriebnahme des Ger tes Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene und die Sicherheit Dritter Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen Wagen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung Reinigen Sie das Ger t niemals mit L sungsmitteln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch Soll das Ger t transportiert werden verwenden Sie bitt
25. t Line Pegel Ausg ngen m Zonen Ausgange Jede Zone verf gt ber einen Stereo Ausgang 2x XLR sym f r links und rechts Mit dem PAN Regler bestimmen Sie die Balance zwischen dem linken und rechten Ausgang Ausg nge STEREO A f r Beschallungszone 1 Ausg nge STEREO B f r Beschallungszone 2 Ausg nge STEREO C f r Beschallungszone 3 Ausg nge STEREO D f r Beschallungszone 4 6 INSTALLATION Spannungswahlschalter Achten Sie auf die richtige Einstellung Netzanschluss mit Sicherungshalter Stecken Sie hier die Netzleitung ein Ersetzen Sie die Sicherung nur bei ausgestecktem Gerat und nur durch eine gleichwertige Sicherung Der korrekte Wert ist am Gerat angegeben Dieses Ger t ist f r ein 19 Rack 483 mm vorgesehen Bei dem Rack sollte es sich um ein Double Door Rack handeln an dem sich sowohl die Vorder als auch die R ckseite ffnen lassen Das Rackgeh use sollte mit einem L fter versehen sein Achten Sie bei der Standortwahl des Ger tes darauf dass die warme Luft aus dem Rack entweichen kann und gen gend Abstand zu anderen Ger ten vorhanden ist Dauerhafte berhitzung kann zu Sch den an dem Ger t f hren Sie k nnen das Ger t mit vier Schrauben M6 im Rack befestigen Werden mehrere Ger te bereinander montiert so ist darauf zu achten dass zwischen den Ger ten mindestens 1 H heneinheit Luft bleibt 8 20 00033027 DOC Version 1 0 7 ANSCHLUSSE ns Vergewissern Sie sich dass der N
26. ung um beim Einschalten das Geh r nicht durch eine zu hohe Lautst rke zu sch digen 2 Schalten Sie das Ger t ber den Netzschalter ein Die Betriebsanzeige POWER auf der Frontplatte leuchtet Schalten Sie anschlie end die angeschlossenen Ger te ein zuletzt immer den Endverst rker f r die Lautsprecher 3 Stellen Sie mit dem LEVEL Regler das gew nschte Lautst rkeverh ltnis f r die Signalquelle ein 4 Bestimmen Sie f r die Signalquelle mit dem PAN Regler die Balance zwischen dem linken und rechten Ausgang 5 Schalten Sie nach dem Betrieb das Ger t wieder mit dem Netzschalter aus BEDIENUNG Reihe CH 1 Zone A Zone B Zone C Zone D Geeeeeee Stereo Ausg nge oder Mono Ausg nge 1 8 MZD 88 ns Die Grafik zeigt die Zuordnung des Signals von CH 1 auf alle Stereo Ausg nge Verwenden Sie den LEVEL Regler in der gleichen Zone STEREO A OUT 1 2 der zweiten Reihe CH 2 um das Signal von CH 2 auf die STEREO A Ausg nge zu geben Verwenden Sie die Regler LEVEL und PAN auf der Frontplatte des MZD 88 um Stereo Mixe herzustellen Jede Reihe auf der Frontplatte z B CH 1 ist einer Eingangsbuchse zugeordnet Jede Zone auf der Frontplatte z B STEREO A OUT 1 2 ist einem Paar Ausg ngen zugeordnet Verwenden Sie den LEVEL Regler um ein Signal auf jeden Stereo Ausgang zu senden Verwenden Sie den
27. ung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden 1 EINF HRUNG Wir freuen uns dass Sie sich f r den OMNITRONIC Matrix Zonen Verteiler MZD 88 entschieden haben Sie haben hiermit ein zuverl ssiges und leistungsstarkes Ger t erworben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie das Ger t aus der Verpackung 2 SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender unbedingt die Sicherheits hinweise und die Warnvermerke beachten die in dieser Gebrauchsanweisung enthalten sind IZ Unbedingt lesen Bei Sch den die durch Nichtbeachtung dieser Bedienungsanleitung verursacht werden erlischt der Garantieanspruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an d
28. very person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet 1 INTRODUCTION Thank you for having chosen the OMNITRONIC Matrix Zone Distributor MZD 88 You have acquired a reliable and powerful device If you follow the instructions given in this manual we can assure you that you will enjoy this device for many years Unpack your OMNITRONIC MZD 88 2 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual US Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might dama

Download Pdf Manuals

image

Related Search

Related Contents

HP Wireless Mini Speaker S6000 (Purple)  Hafler DH-100 User's Manual  InLine 76133G networking cable  1 Press MENU.  ILX Lightwave -- LDT-5980  長瀬産業株式会社 第97回定時株主総会招集ご通知  the full 155-Point inspection checklist - Nissan Certified, Pre  Multi Function Controller User`s Manual  Thank you, and congratulations on your choice of  Manual do usuário  

Copyright © All rights reserved.
Failed to retrieve file