NuTAP-S61 User`s Manual

image

Contents

1. eese 10 3 NUTAP S61 Management caseus eor iex vi ik Soa Fa ka a V ru Eon uy xr A A Ek n RES 11 3 1 Managing NuTAP S61 with NuSet MiniTAP ee eeeeeee er reeee enne nnn 11 3 2 Managing NuTAP S61 with PC s Web Browser e ee eeeee eere eene nennen nnn 13 3 2 1 Accessing NuTAP S61 Configuration Webpage eese 14 3 2 2 NuTAP S61 Configuration Webpage Overview eee 15 3 2 3 NUTAP S61 Configuration Webpage System sees 16 3 2 4 NUTAP S61 Configuration Webpage Statistics 19 3 2 5 NuTAP S61 Configuration Webpage Maintenance 21 3 3 Managing NuTAP S61 with HyperTerminal eeeeee e reeee eene een 23 3 3 1 HyperTerminal Settings for NuTAP S61 e eeceee eee eeeeeer eene enne n nnn 23 3 3 2 NUTAP S61 HyperTerminal Commands ee eeeeeeeee rere eene 25 A NuTAP S61 HyperTerminal Command system eere 26 B NUTAP S61 HyperTerminal Command counter eres 28 C NuTAP S61 HyperTerminal Command mode
2. cseeee eese 29 D NUTAP S61 HyperTerminal Command monitor cesses 29 E NuTAP S61 HyperTerminal Command tapport sseeuss 30 E NuTAP S61 HyperTerminal Command ip 11 eeee eese reee eene 34 F NUTAP S61 HyperTerminal Command CIS eese 34 G NuTAP S61 HyperTerminal Command logout esee 34 XTRAMUS TECHNOLOGIES 4 E mail sales Qxtramus com Website www Xtramus com XTRAMUS 1 NUTAP S61 Overview 1 1 General Description of NUTAP S61 NuTAP S61 is a portable network TAP device Embedded with 2 Network Ports and 2 Monitor Ports NuTAP S61 can monitor and redirect any data streams which flow through it Moreover Nu TAP S61 s Console Port allows users to access test data and configure test variables while serving as an optional power source for NuTAP S61 Network TAP is a hardware device which allows monitoring data flows in a network environment dynamically without any interference As mentioned above NuTAP S61 is embedded with two Network Ports and is capable of monitoring all data flows between two network points All data traffic flows between NuTAP S61 s Network Port AO and A1 can be brought out for further analysis and research dynamically and without intervening network environment
3. po AAA 114 448 178 352 The Monitor Port button allows you to view Counter Report of Nu TAP S61 NuTAP 311 s Monitor Ports XTRAMUS TECHNOLOGIES 71 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 8 Universal Stream Counter USC Report Each of NuTAP S61 NuTAP 311 s Network Port contains two sets of USC Universal Stream Counter allowing you to view real time statistics of network events during packet monitoring and capturing There are two ways to access Universal Stream Counter Report Accessing Universal Stream Counter USC Report T NuSet MiniTAP File Contig Report Service Languages Help Counter Report e Click Universal Stream Counter USC Reconnect Universal Stream Counter LUSC Report Report located on Report in the Menu Bar Capture Network Port AD Packets Iu TAP j Capture Network Port 41 Packets NuSet MiniTAP Fil Config Report Service Languages Help Click the Universal Stream Counter USC i in E p E To Y Report button located on Quick Launch Reconnect Counter USE Cap 40 Cap Al Net Buttons NuTAP S61 Univel Universal Stream Counter Report m i Ji i E Save Update Clear Hide Show Setting Port amp OJLIS CLE For amp OJLIS CX Port A USCH Port ATILISCHT Network Port ADILISCAO Network Port AD LIS C DA Line A ate M bps Packets DA Line Hate Mbps Packets ot DO DD DO DD 0 00 Zewo 00 00 00 00 0 00 AA 00 00 00 01 0 00 Awa 00 00 00 01 0 00
4. C System Status Overview D Test Running Status Icon This icon shows the test running status of NuSet MiniTAP You can make detail configurations and view real time testing diagrams on the Main Display Screen This icon shows the connection status between your PC and NuTAP S61 NuTAP 311 Main Display Screen F USB Connection Status XTRAMUS TECHNOLOGIES 44 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 NuSet MiniTAP Functions 3 1 Menu Bar Fie Config Report Service Languages Help NuSet MiniTAP s Menu Bar contains configuration options such as File Config Report Service Languages and Help Please refer to the sections down below for detail information regarding to each configuration option 3 1 1 File Eile Load Default Config Profile Load Existing Config Profile Save Contig Exit Function Descriptions File The Load Default Config function allows xl you to set all NuSet MiniTAP s settings to default value Click YES to load NuSet MiniTAP s default value or click NO to cancel Load Default Are you sure to load default Config Profile Load a previously saved configuration file Load Existing and applies these settings to NuSet MiniTAP Config Profile Ai the configurations you ve made will be saved as k tcfg files Save the current configuration as a k tcfg Save Config file All saved configuration files can be loaded wit
5. This field displays how NuTAP S61 acquires its IP address e Static NuTAP S61 s IP subnet mask and gateway addresses are assigned manually e DHCP NuTAP S61 s IP subnet mask and gateway addresses are assigned automatically by a DHCP server IP Address NuTAP S61 s IP address Subnet Mask NuTAP S61 s subnet mask Gateway Network Port A0 A1 Nu TAP S61 s gateway address Link status of NuTAP S61 s Network Port A0 A1 MO M1 XTRAMUS TECHNOLOGIES 16 Link status of NuTAP S61 s Monitor Port MO M1 E mail sales xtramus com Website www Xtramus com XTRAMUS System Configuration There are 3 options available for System Configuration which includes e IP Settings Allows you to set how NuTAP S61 will acquire its IP subnet mask and gateway addresses Also you could input these addresses manually here e User Settings Allows you to change NuTAP S61 s configuration webpage User Name and Password e Device Name You can assign an alias for NuTAP S61 here Please see the sections for detail descriptions about settings available in System Configuration A IP Settings IP Configuration IP Address subnet Mask Gateway 1 32 168 1 1 You can choose how NuTAP S61 acquires its IP subnet mask and gateway addresses There are two modes available IP Mode e Static You have to input NuTAP S61 s IP subnet mask and gateway addresses manually in the fields down below e DHCP NuTA
6. e Default User Name admin e Default Password admin x Please note that the User Name and Password are case sensitive For safety issues it is highly recommended that you should change the User name and Password when logging to Nu TAP S61 s configuration webpage for the first time Please refer to B User Settings on Page 19 for more detail descriptions about how to change NuTAP S61 s User Name and Password After inputting NuTAP S61 configuration webpage s User Name and Password you should be able to see NuTap S61 s configuration webpage displayed on your web browser as shown in the figure down below NuTAP S61 Windows Internet Explorer inl x Gro v EN http 192 168 1 20 a W QyNurAP S61 NuTAP 561 Y System System Information System Information b System Configuration gt Statistics MAC Address 00 22 42 2D 00 00 gt Maintenance FPGA Version v1 0b005 Firmware Version v0 9b007 Management Port IP Mode Static IP Address 192 168 1 20 Subnet Mask 255 255 253 0 Gateway 192 168 1 1 Network Port AO Link Down A1 10M Full MO Link Down M1 Link Down XTRAMUS TECHNOLOGIES 14 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 2 2 NuTAP S61 Configuration Webpage Overview NuTAP 561 gt System P Statistics Sy stem Information Maintenance TM MAC Address DOUZ AC DOUDOU FPGA Versio
7. 2 Select the COM port of PC for this connection Click OK to continue Phone number Connect using cara Port Settings Bits persecone 38400 WI 3 Set the COM port parameters according to the settings listed down below Data bits ic E e Bits per second 38400 Parity Noe e e Data bits 8 e Parity None o nn e Stop bits 1 erem e Flow control None Click OK to continue Restore Defaults ENPUN p MUTAP S61 liyperTernminal Dji fl EA yen Cab Jede Heb HulHP S61 Ethernet TAP Equipment Command Line Interface Copyright C 2010 XKtranus Technologies All rights reserved at Login NuTAP S61 Series gt User Mame contacted 00110 Raho detect AH U N 1 Num Click the Enter key on your keyboard to start setting NuTAP S61 via HyperTerminal To log in please type NuTAP S61 s user name and password e Default User Name admin e Default Password admin Both the User Name and Password are case sensitive If you change NuTAP S61 s user name and password with NuTAP S61 s configuration webpage please log in with the new user name and password here XTRAMUS TECHNOLOGIES 24 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 3 2 NUTAP S61 HyperTerminal Commands g NuTAP S61 HyperTerminal l loj x File Edit View Cal Transfer Help Dae 9 3 S e user name admin user passworg Melcome NuTAP 361 Command Menu Command des
8. 2o 00 00 00 02 0 00 Awa 00 00 00 02 0 00 om o 00 00 00 03 0 00 Awa 00 00 00 03 0 00 om o 00 00 00 04 0 00 Awa 00 00 00 04 0 00 om 00 00 00 05 0 00 Aa DD DO DO 05 0 00 AA 00 00 00 06 0 00 A 00 00 00 06 0 00 om 00 00 00 07 0 00 Aa 00 00 00 07 0 00 om 00 00 00 08 0 00 Awa 00 00 00 08 0 00 T AN 7 a rl Network Pon AVUSCHO Network Port A1 LISCE DA Line A ate M bps Packets DA Line Hate Mbps Packets om 00 00 00 00 0 00 Ao DD DO DO DD 0 00 Pe 00 00 00 01 0 00 AZA 00 00 00 01 0 00 res 00 00 00 02 0 00 Awa 00 00 00 02 0 00 rese 00 00 00 03 0 00 Awa 00 00 00 03 0 00 om 00 00 00 04 0 00 ot DD DO DD D4 0 00 AA 00 00 00 05 0 00 Awa 00 00 00 05 0 00 AA ot 00 00 00 06 0 00 Aa 00 00 00 06 0 00 om 00 00 00 0 0 00 ees DD DD DD D 2 0 00 om 00 00 00 08 0 00 Zewo 00 00 00 06 0 00 7 2 T A 2 a rl Please see the sections down below for detail description regarding to Universal Stream Counter Report XTRAMUS TECHNOLOGIES 72 E mail sales xtramus com Website www Xtramus com XTRAMUS rd Save Update m Hh dp F Clear Hide Show Setting Port AD USC 0 Port AWUSCH Port AT USCREO Part A1 LISCH1 Universal Stream Counter USC Control Buttons Descriptions SAVE The Save button allows you to save the current Universal Stream Counter reporis to Microsoft Excel amp format files Ipdate The Update button allows you to start stop updating statistics displayed in the Main Display Window On Clear
9. 3 A Send File window will pop up Please set the Protocol to Xmodem and click the Browse button LITTLE risi Folder C Documents and Settings NuTAP SB1 ATC vo 96007 Filename Browse Frotocol modem Send Close Cancel 4 Choose the firmware you would like to upgrade to and click Open Look in C3 NuTAP S61 RTC v0 9b007 v E F 9 Er My Recent Documents Desktop MuTAP S61 RTC vO 9b007 E NuTAP 561 RTC v0 9b007 hex KA My Documents s My Computer ETE File name NuTAP S61 RTC w0 9b007 fi m Wa re F P G A Pis Files of type aumes S v Cancel l A Contd 5 Click the Send button to start sending firmware Misendrile o2 Folder D 4MuTAP SB1 Firmeare amp FFGASSMuTAP S61 ATC vo 9bl Filename D ANuTAP SE1 FirmwaretFPGANH uTAP 561 RTI Protocal modem Send Close Cancel 6 System is sending firmware to NuTAP S61 xmodem file send for test Sending D ANuTAP S61 Firmware amp FPGASNuTAP SB81 RTC wO 3b00ANuTAP SE6 Packet n Error checking CRC Retries o Total retries o Last error Fie 3K of 337K Elapsed 00 00 01 Remaining Throughput 7 NuTAP S61 will reboot when finishing upgrading its firmware reset The system reset command allows you to reset all NuTAP S61 s settings back to the default values reboot The system reboot com
10. NuTAP S61 User s Manual XTRAMUS Foreword Copyright Copyright 2010 Xtramus Technologies all rights reserved The information contained in this document is the property of Xtramus Technologies No part of this publication shall be reproduced stored in a retrieval system or transmitted in any form or by any means without the prior written permission of Xtramus Technologies Disclaimer The information contained in this document is subject to change without notice and does not represent a commitment on the part of Xtramus Technologies The information in this document is believed to be accurate and reliable However Xtramus Technologies assumes no responsibility or liability for any errors or inaccuracies that may appear in the document Trademarks NuTAP S61 is a trademark or registered trademark of Xtramus Technologies All other trademarks and registered trademarks are the property of their respective owners Warranty Xtramus Technologies warrants for the hardware provided along with this document under proper usage and conditions in normal environment any improper operation or in irregular environment may possibly cause this product NOT function well For detailed terms please contact your local dealer Contact Information Xtramus Technologies E mail sales xtramus com Website www xtramus com Tel 886 2 8227 6611 Fax 886 2 8227 6622 XTRAMUS TECHNOLOGIES 9 E mail sales xtramus com Website www Xtramus c
11. NuTAP S61 is a compact lightweight and highly cost effective device that provides 3 different filters for users to choose Forwarding Filter Re Direct Filter and Capture Criteria All these filters are powered by Xtramus SDFR Self Discover Filtering Rules which makes packet capturing filtering over Ethernet easy and convenient NuTAP S61 block diagram Nework Port 2 10M 100M PHY Power loss MUX Relays Rate Control Li bu Captrue Buffer Packet Parser Port Counters p 255set Universal Filters amp Selection CPU and q gt Stream Counters Management Unit Monitor Add 10M Port B Tet ME m eaders PHY Monitor Nework 10M Port 1 100M PHY FS Rate Control n 255set Universal Stream Counters a iui Add 10M Port A Head 100M eaders PHY Packet Parser Port Counters Captrue Buffer XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com XTRAMUS 1 2 Key Features of NuTAP S61 Portable and light weighted with high performance and reliable test results Filter and redirect TAP streams to monitor port by SDFR technique which can ease the loading of monitor PC SDFR Self Discover Filtering Rules a set of filtering rules including Destination Address Source Address VLAN Destination IP Source IP Destination Port and Source Port 2 Network Ports and 2 Monitor Ports of 10 100 Mbps RJ45 Ethernet port 1
12. The Clear button allows you to clear all statistics displayed in the Main Display Window M Hide The Hide button allows you to hide all statistics displayed in the Main Display Window A Show The Show button allows you to show all statistics displayed in the Main Display Window Setting USC Setting X Port AD USC O Port ABDJUSCsH Port A1fUSC O Port atuse Operation Mode MormalMade Jitter Mode Rule Rule Based an DA vi Begin Stream DA Ez xx 00 D0 00 00 A USC Setting window will pop up if you click the Setting button allowing you to set USC criteria for Port AO USCZO Port A0 USC 1 Port A1 USC 0 and Port A1 USC 1 To choose the Universal Stream Counter you would like to configure please click the tab menu on the upper part of the USC Setting window Operation Mode e Normal Mode The Universal Stream Counter will run under Normal Mode e Jitter Mode The Universal Stream Counter will run under Jitter Mode Please note that when under Jitter Mode additional statistics regarding to packet jitter will be displayed in the Universal Stream Counter Report Delta Current Current time interval between packets Time Maximum Maximum time interval between packets ns Minimum Minimum time interval between packets Jitter ns Max Delta Time Min Delta Time Jitter Rule e Rule You can set the USC rule base on DA SA VID MPLS DIP SIP DPort SPort
13. 0 MAC 00 22 2 27 00 01 Er 2 Network Part AU Status E yo Connection Mode Auto All A e Link Status Bee D Link Link Up a Speed 100M Full D Flow Control Off 20 Rate Control Off B T Network Part amp 1 Status a 9 Connection Made Auto All 2o Link Status be D Link Link Up MEM f3 Speed 100M Full O Flow Control Ott 0 Rate Control Off A T Monitor Part MO Status B o Connection Mode Auto All A e Link Status Be i Link Link Up a aa AQ Speed 100M Full E Flow Control Off ta Monitor Part ki Status c o Connection Made Auto All m e Link Status Be 0 Link Link Up a Q Speed 100M Full LAJ Flow Control Off The System Status Overview allows you to view NuTAP S61 NuTAP 311 s system information Network Port AO A1 status and Monitor Port MO M1 status You can unfold the list with the button and fold the list with the zi button 3 4 Test Running Status Icon The Test Running Status Icon indicates if there s a test running Test Running Status Icon No test is underway Test is running XTRAMUS TECHNOLOGIES 54 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 5 Network Port Setting You can configure filtering capture criteria and pattern check for Network Port AO A1 in the Port Config Network Port screen There are two ways to access Port Config Network Port Accessing Port Config Network Port 4 NuSet MiniTAP
14. DPort Destination Port and VLAN TAG VID VLAN ID SPort Source Port IP Fragment MTU Maximum Transmission Unit m Apply Apply and save the changes you ve made on this page After making any settings iid on this page you must click the Apply button or all changes will be lost XTRAMUS TECHNOLOGIES 67 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 7 Counter Report You can view NuSet MiniTAP s counter report chart of NuTAP S61 NuTAP 311 s Network Port and Monitor Port with Counter Report There are two ways to access Counter Report Accessing Counter Report oT NUSet MiniTAP File Config Counter Report Reconnect Capture Network Port AD Packets Nu TAP ji Capture Network Port 41 Packets El Sf NuTAP S61 EQ System Information wolf SIM 10TAPOOOOO1 NuSet MiniTAP File Config Report Service Languages Help EE usc NuTAP 361 El Sf NuTAF 8B1 EE System Information SIN 10TAPO00001 Reconnect Cap 40 Cap 41 Universal Stream CounteriLISC Report 2 Save Counter Report 2 Save jork Port AD Net e Click Counter Report located on Report in the Menu Bar er Report LUI Clear 9 Update Network Port AQ Net e Click the Counter Report button located on Quick Launch Buttons 9 Lpdate Bon Clear Counter Report 000 at Hide as QY Save Update Clear E Tx Collision Te Single Collision i Tx Multi Co
15. File Config Report Service Languages Help Network Port 40 Le E AA mem AD Se ed MM c x e Click Network Port A0 A1 located on Config Monitor Port M1 Port Config Network Port A0 in the Menu Bar Port Configuration EE 2 Forwarding Filter Capture Criteria Re dire System Configuration i Sik 1 TAPODODD coal MAC nn 22 A2 27 nn m Filter all packets Protocol SOFR Result 4 NuSet MiniTAP File Config Report Service Languages Help I o Network Port AD RA Cap AD Cap Al Network Port AB Network Port A1 f Monitor w Click the Network Port AO A1 button located Monitor Part MO Manitor Part M1 Port Config Network Port A0 Pork Configuration on Quick Launch Buttons Farwarding Filter Capture Criteria Fe dire System Configuration siN 10TAP000001 OH MAC nn 22 2 27 nn nt Filter all packets Port Config Network Port A0 Forwarding Filter Capture Criteria Re direct Filter Pattern Check Protocol SDFR Result Filter all packets Protocol BDFR Result MAC Network Protocol Broadcast ARP m TCP Multicast IPv4 UDP Unicast IPv6 PAP VLAN ICMP m RTP M QinQ Double VLAN Tag IPCS Error CRC Error Pattern Check Description Transmitted packets from Network Port AD to Al or the other way around that meetthe criteria set in Forwarding Filter will be filtered out or through Forwa
16. SIP amp DIP and DA amp SA amp SIP amp DIP DFR Rule Setting The Rule Setting field allows you to set and input the value of DA SA DIP and SIP The value of SDFR parameters can be set as Single Pair and Range The following descriptions will use DA as example gt DIP Destination IP Address gt SIP Source IP Address As mentioned above each parameter is independent and can be activated in any combinations of DA SA SIP DIP DA amp SA DA amp SIP DA amp DIP SA amp SIP SA amp DIP D pa O sa 7 sp pip DA 4 SA DA a SIP DA amp DIP 7 sA a SIP 4 amp DIP SIP amp DIP DA amp SA amp SIP amp DIP DA Singe n0 00 00 00 00 00 Single A single value will be used as SDFR parameter DA Pair no 00 00 00 00 00 er n0 00 00 00 00 00 Pair Two values will be used as SDFR parameters D Range 00 00 00 00 00 00 lt DAS 00 00 00 00 00 00 DFR Current Filter Technical Terms Range Values within the range of the two values set here will be used as SDFR parameters The Current Filter field displays the settings you ve made while the Technical Terms field displays the explanations for DA SA DIP and SIP DFR Button apply XTRAMUS TECHNOLOGIES 57 Apply Apply and save the changes you ve made on this page After making any settings on this page you must click the Apply button or all changes will be lost
17. allows you to set the criteria for Capture Criteria for packets flow from Network Port A0 to A1 If you would like to set Capture Criteria for packets flow from Network Port A1 to AO please use the a1toa0 sub command instead The following sections will use a0toa1 as example Please see the sections down below for detailed descriptions regarding to the commands and parameter available here tapport Contd The tapport a0toa1 cap type all pattern qing vlan rtp ftp udp tcp arp icmp lipv6 ipcserror ipv4 crcerror uc mc bc sdfr command allows you to set the packet criteria for Capture Criteria from Network Port AO to A1 The criteria available here includes e all Select all e all Select all e all Select all e pattern Pattern Check e pattern Pattern e pattern Pattern e qinq QinQ Double Check Check VLAN TAG e ging QinQ Double e ging QinQ Double e Vlan VLAN VLAN TAG VLAN TAG e rtp RTP Protocol e Vlan VLAN e Vlan VLAN e ftp FTP Protocol e rtp RTP Protocol e rtp RTP Protocol e ftp FTP Protocol e ftp FTP Protocol For example to add UDP RTP and ICMP as Capture Criteria for packets flow from Network Port AO to A1 please input the command tapport a0toa1 cap type udp rtp icmp SDFR stands for Self Discover Filtering Rules The tapport a0toa1 capsdfr da a da b da s sa a sa b sa s dip a dip b dip s sip a sip b sip s Parameter allows you to set
18. 00 00 05 2X 00 00 00 06 2X 00 00 00 07 2X 00 00 00 08 Line Rate Mbps 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 moo Packets 20s 00 00 00 00 28 0 00 00 00 01 2X 00 00 00 02 2X 00 00 00 03 2X 00 00 00 04 8 2 00 00 00 05 2 00 00 00 06 X 8 00 00 00 07 2X 00 00 00 08 Network Port ATIUSCH1 Line Rate Mbps Packets n Te Up to four Universal Stream Counter Reports can be displayed at the same time as shown in the figure above You can view each Universal Stream Counter s DA Destination MAC Address Line Rate Mbps Packets Bytes Broadcast Multicast IPCS Error and CRC Error on the Universal Stream Counter Report E mail sales xtramus com XTRAMUS TECHNOLOGIES 74 Website www Xtramus com XTRAMUS Note Information and specifications contained in this document are subject to change without notice All products and company names are trademarks of their respective corporations Copyright 2010 Xtramus Technologies all rights reserved Do not reproduce redistribute or repost without written permission from Xtramus Doc USM NuTAP S61 V1 2 ENG Draft 20110728 XTRAMUS TECHNOLOGIES 75 E mail sales xtramus com Website www Xtramus com
19. 10M Full duplex Force 100M Full Set all Network Ports and Monitor Ports to 100M Full duplex x When Flow Control is enabled the Media Type Flow Control Rate Control transmitting rate will drop if traffic overflow b ER t Nu TH Port OCCUIS C On Of C On it Off Configuration You can set the transmitting receiving rate for Network Port A0 A1 if Flow Control is enabled gt On Enable Flow Control ae ee gt Off Disable Flow Control Mate i Changing Flow Control or Rate Control settings might cause Please note that before making Rate Link nee changes and packet loss i Control settings Network Port AO A1 s Flow Control function must be enabled Port Configuration xj Media Type Flow Contro Rate Control Network Port AU Network Port Al on i Off Hate 0 00 hibps C On v Off Hate 0 00 Mbps gt On Off Enable Disable Rate Control Rate When Rate Control is enabled you can set the transmitting receiving rate for Network Port A0 A1 XTRAMUS TECHNOLOGIES 46 E mail sales xtramus com Website www Xtramus com XTRAMUS Function Descriptions Config LLL unction Descriptions Config System Configuration You can set NUTAP S61 NuTAP 311 s IP DNS and TFTP here in this field These settings will be used when connecting NuTAP S61 NuTAP 311 to an existing network and access NuTAP S61 NuTAP 311 via configuration web pages Click Apply located on the bu
20. Destination IP Address A da b Destination Address B dip b Destination IP Address B da s Destination Address Single dip s Destination IP Address Single sa a Source Address A sip a Source IP Address A sa b Source Address B sip b Source IP Address B e Sa s Source Address Single e Sip s Source IP Address Single The Parameters should follow the format listed in the table down below e DA SA XX XX XX XX XX XX e DIP SIP XXX XXX XXX XXX For example to set SDFR for filtering packets with the destination IP address of 192 168 1 1 from Network Port AO to A1 please input the command tapport a0toa1 fwf sdfr dip s 192 168 001 100 sdfr Sub Commands The tapport a0toa1 fwf sdfr mode da sa dip sip range pair single command allows you to set the SDFR rule settings You can set SDFR for filtering DA SA DIP SIP in range pair or for single one mode The tapport a0toa1 fwf sdfr trig mac amp ip ip sa amp dip sa amp sip da amp dip da amp sip mac dip sip sa da command allows you to set the criteria to trigger trig SDFR trig reset The tapport a0toa1 fwf reset command allows you to reset all Forwarding Filter settings for packets flow from Network Port AO to A1 XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com ATRAMUS Command Descriptions tapport Setting Capture Criteria cap The tapport a0toa1 cap Command Parameter
21. E mail sales xtramus com Website www Xtramus com ATRAMUS C Forwarding Filter Result Frotocol BDFR Result CRO error DA Si amp SIP DIP 4 DA Range OO O0 00 00 00 00 FF FF FF FF FF FF Si Range 11 11 11 11 11 11 22 22 22 22 22 22 DIP Range 192 188 1 1 192 168 1 100 SIP Range 192 168 10 1 192 168 10 100 Result The Result page will display the settings you ve made in Protocol and SDFR pages XTRAMUS TECHNOLOGIES 58 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 5 2 Capture Criteria Capture Criteria Network Port AD Criteria Trigger H hui Network Port J AT1 With Capture Criteria transmitted packets from NuTAP S61 NuTAP 311 s Network Port AO to A1 or the other way around that meet the criteria set in Capture Criteria will be captured and stored in Nu TAP S61 s buffer memory All packets captured and stored this way can be accessed via any Monitor Port upon user requests A Capture Criteria Protocol Forwarding Filter Capture Criteria Re direct Filter Pattern Check Protocol amp DFR Result Capture all packets MAC Network Protocol Broadcast ARP m TCP Multicast IPv4 UDP Unicast Pv6 BENE VLAN ICMP RTP QinQ Double VLAN Tag IPCS Error CRC Error Pattern Check Description Transmitted packets from Network Port AD to Al forthe other way around
22. The tapport a0toa1 fwf Command Parameter command allows you to set the criteria for Forwarding Filter from Network Port A0 to A1 If you would like to set Forwarding Filter from Network Port A1 to AO please use the a1toa0 sub command instead The following sections will use a0toa1 as example tapport fwf Command type The tapport a0toa1 fwf type all pattern ging vlan rtp ftp udp tcp arp icmp ipv6 ipcserror ipv4 crcerror uc mc bc sdfr command allows you to set the packet criteria for Forwarding Filter from Network Port AO to A1 The criteria available here includes e all Select all e udp UDP Protocol e ipv4 IPv4 e pattern Pattern Check e tcp TCP Protocol e crcerror CRC Error e ging QinQ Double e arp ARP e uc Uni cast VLAN TAG e icmp ICMP e mc Multi cast e vian VLAN e ipv6 IPv6 e bc Broadcast e rtp RTP Protocol e ipcserror IPCS Error e sdfr Self Discover e ftp FTP Protocol Filtering Rules For example to add UDP RTP and ICMP filter from Network Port AO to A1 please input the command tapport a0toa1 fwf type udp rtp icmp sdfr SDFR stands for Self Discover Filtering Rules The tapport a0toa1 fwf sdfr da a da b da s sa a sa b sa s dip a dip b dip s sip a sip b sip s Parameter allows you to set the SDFR for Forwarding Filter from Network Port AO to A1 The criteria available here includes e da a Destination Address A dip a
23. XTRAMUS 2 NuSet MiniTAP Overview 2 1 Starting NuSet MiniTAP Before starting NuSet MiniTAP please be sure that your NUTAP S61 or NuTAP 311 is properly connected to your PC The figure down below is an example for connecting NUTAP S61 to PC via an RJ45 to USB cable PC s USB Port rA E PC Running NuSet MiniTAP You can start NuSet MiniTAP by Starting NuSet MiniTAP iNuSet MiniT P y1 0b000 rG Muset MiniTAP v1 0b000 947 Connected via RJ45 to USB Cable NuSet MiniTAP v1 0b000 Uninstall NuSet MiniTAP v1 Ob000 Welcome to Xtramus Settings Search Help and Support Ri un De Gong Repot Zee Legum wo If your PC is not connected with NuTAP S61 NuTAP 311 you can still run NuSet MiniTAP under Demo Mode Almost all NuSet MiniTAP s functions are available under Demo Mode However please note that Demo Mode is for system demo purposes only and does not serve any testing purposes at all e usc Cap AD Cap Al NuTAP S61 Console Port Double click NuSet MiniTAP icon located on your PC s desktop gt Click Start gt Programs gt Xtramus NuSet MiniTAP gt NuSet MiniTAP PA mi xi DEMO x v v e e e o Network Port AO Network Pert AL Porter Port MO Morto Port Mi System Jen Connected XTRAMUS TECHNOLOGIES 43 E mail sales xtramus com Website www Xtramus com ATRAMUS 2 2 NuSet MiniTAP Main Window Overview NuSet M
24. XTRAMUS TECHNOLOGIES 52 E mail sales xtramus com Website www Xtramus com ATRAMUS 3 2 5 Network Port A0 A1 Function Descriptions Network Port A0 A1 Network Part an e Network Port A0 A1 buttons located on the Quick Launch Buttons allow you to make settings regarding to Network Port A0 A1 on the Main Display Screen For more detail information please refer to 3 5 Network Port Settings on page 21 Network Port A1 3 2 6 Monitor Port MO M1 Function Descriptions Monitor Port MO M1 The Monitor PortM0 M1 buttons located on the Quick Launch Buttons allow you to make settings regarding to Monitor Port MO Mi1 on the Main Display Screen For more detail information please refer to 3 6 Monitor Port Settings on page 33 Monitor Part MO Monitor Part Mi 3 2 7 System Function Descriptions System The System button located on the Quick Launch Buttons allows you to set Nu TAP S61 NuTAP 311 s IP DNS and TFTP here in this field These settings will be o used when connecting NuTAP S61 NuTAP 311 to an existing network and access HEEM NuTAP S61 NuTAP 311 via configuration web pages For detail description regarding to this function please refer to 3 1 2 Config System Configuration on page 13 XTRAMUS TECHNOLOGIES 53 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 3 System Status Overview NuTAP S61 ELS NuTAP S61 E 9 System Information O4 Sin 1 TAPODDOD
25. and VLAN CoS VLAN Class of Service with the Rule scroll down menu e Begin String You can input the value of DA SA VID MPLS DIP SIP DPort SPort and VLAN CoS VLAN Class of Service here in this field gt OK Apply the changes you ve made and exit Cancel Cancel the changes you ve made and exit gt Apply Apply the changes you ve made without exit XTRAMUS TECHNOLOGIES T3 E mail sales xtramus com Website www Xtramus com XTRAMUS Universal Stream Counter USC Control Buttons Descriptions The Port A0 USC 0 Port AO USCH1 Port A1 USC 0 and Port A1 USC 1 buttons allows you to display Network Port A0 s USC Counter 0 Network Port A0 s USC Counter 1 Network Port A1 s USC Counter 0 and Network Port A1 s USC Counter 1 Network Port A0 USCX Network Port amp 0 US C3 Port AUS Cao Port ADILISLAN Port ATILISCADO Port ATIS CA 4X 00 00 00 00 4X 00 00 00 01 2X 00 00 00 02 X 4X 00 00 00 03 8 X 00 00 00 04 2X 00 00 00 05 2X 00 00 00 06 X 2X 00 00 00 07 4X 00 00 00 08 Line Rate Mbps 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 oo Packets z ow E 22x 22 00 00 00 00 8 X 00 00 00 01 X 24X 00 00 00 02 4X 00 00 00 03 2X 00 00 00 04 X 4X 00 00 00 05 X 2X 00 00 00 06 XX 2X 00 00 00 07 4X 00 00 00 08 Network Port A1 USCHO Line Rate Mbps Packets 2X 00 00 00 00 44 00 00 00 01 2 00 00 00 02 2 00 00 00 03 2 00 00 00 04 2X 00
26. connect to Connection NuTAP S61 NuTAP 311 s configuration webpage 3 1 5 Language Languages w English Simplified Chinese Function Descriptions Language English Chinese Simplified NuSet MiniTAP has 2 different languages for its Ul available You can set the language of UI to either English or Simplified Chinese 3 1 6 Help Help About atramus Web Function Descriptions Help About An About window will pop up and show detailed system information Xtramus Web Open your default web browser and access Xtramus Website www xtramus com XTRAMUS TECHNOLOGIES 54 E mail sales xtramus com Website www Xtramus com ATRAMUS 3 2 Quick Launch Buttons dt iss EE E l OQ Reconnect Counter LIS C Cap 40 Cap Al Network Port 40 Network Port A1 Monitor Port MO Monitor Pork Mi System These Quick Launch Buttons allow you to reconnect NUTAP S61 NuTAP 311 view counter USC Universal Stream Counter statistics and chart set packet capturing criteria and make Network Port AO A1 Monitor Port AO A1 and system configurations Please refer to the section down below for more detail descriptions regarding to Quick Launch Buttons 3 2 1 Reconnect Function Descriptions Reconnect If the connection between your PC and NuTAP S61 NuTAP 311 is down a Disconnected icon amp F 643 Disconnected will be
27. shown in System Connection Status a3 EF Press Reconnect button Reconnect to re establish the connection between your PC and NuTAP S61 NuTAP 311 If the connection has been established successfully a message window will pop up and the System Connection Status will be shown as Connected a Connected 3 2 2 Counter Function Descriptions Counter The Counter Report button located on the Quick Launch Buttons allows you to view lE Network Ports and Monitor Ports counter reports and charts on the Main Display Screen Counter YOu can save the test statistics here as well For more detail information please refer to 3 7 Counter Report on page 34 3 2 3 USC Universal Stream Counter Function Descriptions USC Each of NuTAP S61 NuTAP 311 s Network Port supports two sets of Universal Stream Counter USC The USC button located on the Quick Launch Buttons allows you to view USC statistics on the Main Display Screen You can save the USC statistics here as well For more detail information please refer to 3 8 Universal Stream Counter USC Report on page 38 3 2 4 Cap A0 A1 Function Descriptions Cap A0 A1 The Cap A0 A1 buttons located on the Quick Launch Buttons allow you to capture packets flowing through Network Port A0 A1 For detail description regarding to this Cap 40 Cap A1 function please refer to 3 1 3 Report Capture Network Port A0 A1 Packets section on page 14
28. view all the packets captured by NuTAP S61 Press S on your keyboard to start stop display and press ESC on your keyboard to quit XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com ATRAMUS Setting Re direct Filter red The tapport a0toa1 red Command Parameter allows you to set the criteria for Re direct Filter from Network Port AO to A1 If you would like to set Re direct Filter from Network Port A1 to AO please use the a1toa0 sub command instead The following sections will use a0toa1 as example tapport Contd NuTAP S61 supports two filter sessions with each session has two IPs they are all labeled as ID 0 1 and IP 0 1 tapport a0toa1 red session id 0 id 1 ipzO ipz1 Parameter This command will set the Session 0 or Session 1 s id 0 or id 1 IP O or IP 1 ipzO or ipz1 to a specific IP address ex 192 168 1 1 tapport a0toa1 red session id 0 id 1 mode enable disable This command will set mode enable disable Session 0 or Session 1 s id 0 or id 1 mode with sub commands ds IP 0 as DIP IP1 as SIP sd IP 0 as SIP IP1 as DIP and dsorsd IP 0 1 serve as both DIP and SIP The tapport aOtoa1 red type all pattern qing vlan rtp ftp udp tcp arp icmp ipv6 ipcserror ipv4 crcerror uc mc bc sdfr command allows you to set the Re direct Filter for packets flow from Network Port AO to A1 The criteria available here in
29. 0 Minimun f Maximun 2000 m Horizontal Axis Scale Start Time 2010 10 02 15 09 37 w End Time 2010 10 02 15 10 07 The Pie Mode displays the statistics regarding to the lengths of packets flow through Network Port AO Network Port A1 and Network Port A0 A1 Packets are categorized into the following categories 64 bytes 65 127 bytes 128 255 bytes 256 511 bytes 512 1023 bytes gt 1024 bytes Over Size byte and Under Size End Time 2010 10 02 15 47 53 gt 2010 10 02 15 47 47 2010 10 02 15 47 49 Also clicking the End Time scroll down menu and selecting a time Est A ERE NM Chart listed here allows you to view the Pie Chart of that time eae CM Contd Bar Mode Chart 7 x y Update Line Pie r Vertical Axis Scale Port AD Vertical Axis Scale Port A1 Vertical Axis Scale Port 40 41 Packet pps Auto User Define set Packet pps Auto User Defir Set Packet pps Auta User Define se Minimun f vor 5 Minirnun f Maximun 100 Minimun f unm Horizontal Axis Scale Start Time 2010 10 02 15 09 37 v End Time 2010 10 02 15 10 07 The Bar Mode displays Network Port A0 Network Port A1 and Network Port A0 A1 s statistics including Broadcast Multicast VLAN IPv4 ICMP ARP End Time 2010 10 02 15 47 53 v RTP and Tx Rx Pause 2010 10 02 15 47 47 2010 10 02 15 47 49 A f 1 010 1002 15 47 52 Also clicki
30. 1 Apply Device Name Device Name Input the alias for NuTAP S61 here in this field Apply Apply the changes you ve made here XTRAMUS TECHNOLOGIES 18 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 2 4 NUTAP S61 Configuration Webpage Statistics The Counter Report can display statistics reports of NuTAP S61 s Network Port or Monitor Port Port Statistics JPrt0 Port Toa Link Status LinkDom Unup mma Sped nv Sta tiliza alse TSinge Colson Lin BE Rx Rx Line Rate RX BE Misr ERGO FU amma Mi Pi Pi K tus P t B U tion P D Tx Excession Collision Monitor Port Statistics Porto Port Toa nia speed RxBye d RxPacketRate pps Q Rx Pause Rxutiization 09 RxPase 0 00 TxColisionTimes o 0 RxBoadast 0 0 0 0 0 0 0 00 00 0 0 0 00 00 FxUncast 0 o n O Refresh Refresh the configuration webpage and update the latest statistics Clear Clear all statistics displayed in the table XTRAMUS TECHNOLOGIES 19 E mail sales xtramus com Website www Xtramus com XTRAMUS USC Counter When monitoring data flows in a network environment with Network TAP devices it is common to use packet analyzers or sniffers for capturing and analyzing packet frames However infor
31. 192 168 1 1 from Network Port AO to A1 please input the command tapport a0toa1 red sdfr dip s 192 168 001 100 sdfr Sub Commands The tapport a0toa1 red sdfr mode da sa dip sip range pair mode single command allows you to set the SDFR rule settings You can set SDFR for re directing DA SA DIP SIP in range pair or for single one The tapport a0toa1 red sdfr trig mac amp vid amp ip amp port mac amp ip amp port mac amp ip vid amp ip amp port ip amp port ip amp dp ip amp sp dip amp dp dip amp sp trig sip amp dp sip amp sp ip sa amp dip sa amp sip da amp dip da amp sip mac amp vid mac session1 sessionO dp sp dip sip vid sa da command allows you to set the criteria to trigger trig SDFR session type red Command sdfr reset The tapport a0toa1 red reset command allows you to reset all Re direct Filter settings for packets flow from Network Port AO to A1 XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com ATRAMUS ommand Descriptions tapport The tapport a0toa1 rate value enable disable Parameter command allows you to set enable disable the transmitting rate Rate Control value The tapport a0toa1 rate value Parameter command allows you to set the flow rate bps from Network Port AO to A1 enable The tapport a0toa1 rate enable command will enable the Rate Control disable Th
32. 2010 10 02 15 10 07 The Line Mode displays the statistics about the of packets flow through Network Port AO Network Port A1 and Network Port A0 A1 To display the statistics as line on the chart please click the check box of that statistics Vertical Axis Scale Port AD The Vertical Axis Scale fields allow you to set the scale in pps Packets per Second of the X Axis of the Line Chart The Vertical Axis Scale can be set to Auto or you can set its minimum maximum value by User Define Packet pps Auto User Define Mininun fo Maximun 1000 i The Horizontal Axis Scale field allows you to set the scale of start Time 2010 10 02 15 09 37 the Y Axis of the Line Chart Click the scroll down menus of End Time 2010 10 02 15 10 07 Start Time and End Time to set the statistics during a period of time XTRAMUS TECHNOLOGIES 69 E mail sales xtramus com Website www Xtramus com XTRAMUS Report Control Buttons Descriptions Pie Mode xi e 6 i Update Line Pie Bar Network Port A0 Network Port A1 Network Port A0 A1 512 1023 bytes 10 00 Over Size bytes 0 0096 kaa ez Amon Vertical Axis Scale Port AD gt rWertical Axis Scale Port 41 r Vertical Axis Scale Port 40 41 Packet pps Auto User Define Y Packet pps Auto User Define Y Packet pps 6 Auto User Define 22 Minimun Maximun 1000 Minimun fp Maximun me 10
33. Console Port which allows users configuring test variables accessing test results upgrading firmware FPGA and serving as NUTAP S61 s optional power source while connected to PC with a RJ45 to USB cable x Both Network Ports support Universal Stream Counter USC each USC can contain up to 256 sets of statistics up to 48 bits including Packets Bytes Packet Broadcast CRC Error IPCS Error Packet Multicast and Transferring Rate Utility software NuSet MiniTAP that runs under Windows environment When connecting Nu TAP S61 with your PC via an RJ45 to USB cable it allows users to gt Upgrading NuTAP S61 s firmware and FPGA Monitoring data flows in the network environment gt Configuring test settings and accessing test results gt Setting 2 sets of Session Filter including Port A Port B and Port B Port A Setting SDFR Self Discover Filtering Rules SDFH is a set of filtering rules including Packets Bytes Packet Broadcast CRC Error IPCS Error Packet Multicast and Transferring Rate gt Supports multi language user interface including Simplified Chinese and English Reset Button which allows users to reset all NuTAP S61 s settings back to default value Utility Software that supports multi language user interface including Simplified Chinese and English x Note When using Console Port as NuTAP S61 s power source please use the RJ45 to USB cable that comes with NuTAP S61 package Extending the length of RJ45 to USB c
34. Logout This function allows you to log out and leave NuTAP S61 s configuration webpage You have to login again once you ve logged out XTRAMUS TECHNOLOGIES 22 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 3 Managing NuTAP S61 with HyperTerminal PC s Serial Port m A AN US Connected via RJ45 to Serial Cable NuTAP S61 Console Port d PC Running HyperTerminal NuTAP S61 allows users to make system configurations view test statistics system information with HyperTerminal To access NuTAP S61 via HyperTerminal you have to connect Nu TAP S61 s Console Port with PC s Serial Port via an RJ45 to Serial cable as shown in the figure above 3 3 1 HyperTerminal Settings for NuTAP S61 After connecting the PC s serial port to NuTAP S61 s Console Port via an RJ45 to Serial cable please start the HyperTerminal software installed on your PC and establish connection according to the steps listed down below Establishing Connection with NuTAP S61 Enter a name and choose an icon for the connection Hame NuTAP S61 1 Input a name for this connection such as NuTAP S61 and also select an icon for this connection Click OK to continue XTRAMUS TECHNOLOGIES 23 E mail sales xtramus com Website www Xtramus com XTRAMUS Connect To aj x D HuTAP S61 Enter details for the phone number that yeu want to dial Country region sian 885 mau
35. P S61 acquires its IP subnet mask and gateway addresses automatically from network s DHCP server IP Address You can input NuTAP S61 s IP address here in this field Subnet Mask You can input NuTAP S61 s subnet mask here in this field Gateway You can input NuTAP S61 s gateway address here in this field Apply Apply the changes you ve made here Note The settings in the figure above are only examples and might not work with your network environment XTRAMUS TECHNOLOGIES 17 E mail sales xtramus com Website www Xtramus com ATRAMUS B User Settings Administrator User Name New Password Confirm New Password Guest User Name New Password Confirm New Password For issues regarding to system security NuTAP S61 has 2 different user security levels which are e Administrator User with Administrator privilege can change NuTAP S61 system settings and view system information statistics e Guest User with Guest privilege can only view system information statistics User Settings for Administrator Guest User Name Input the user name here in this field Input the password here in this field Please note that the New Password password must contain at least 5 alphanumeric characters and is case sensitive Confirm New Password Please input the password here again for confirmation Apply Apply the changes you ve made here C Device Name Device Name Device Name NuTAP S6
36. able might cause NuTAP S61 power insufficient XTRAMUS TECHNOLOGIES 6 E mail sales xtramus com Website www Xtramus com XTRAMUS 1 3 NuTAP S61 Panel Function Overview Front Panel Power SYS Console 38400 NuTAP S61 L A NuTAP S61 LEDs Description Front Panel LED LED Status Description Power Green ON NuTAP S61 IS power on General OFF NuTAP S61 is power off SYS Green ON NuTAP S61 is booting properly and is ready for tests Amber ON Error occurred while NuTAP S61 is booting AO A1 Green ON AO A1 IS connected to PC or network Green Blinking A0 A1 is transmitting or receiving packets Network Port 100M 10M Green ON The Network Port is running under 100M 10M Tx rate Full Green ON The Network Ports is running Full Duplex mode OFF The Network Ports is running Half Duplex mode Monitor Port MO M1 Green ON MO M1 IS connected to PC or network Green Blinking MO M1 is transmitting or receiving packets Green ON NuTAP S61 is running under Segregate Mode Re Direct Filter Segregate Green ON NuTAP S61 is running under Aggregate Mode Aggregate XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com XTRAMUS Left Right Panel 12V DC Power Jack A Reset Button Description Left Panel Power Jack Power Jack 12V DC Power Jack x 1 To reset NuTAP S61 s settings to default value please press and ho
37. ation example in the following sections of this manual as well However please note that the settings demonstrated here might not work with your network environment Network IP 192 168 1 1 253 Mask 255 255 255 0 Gateway 192 168 1 254 PC IP 192 168 1 100 Mask 255 255 255 0 Gateway 192 168 1 254 NuTAP S61 IP 192 168 1 20 Mask 255 255 255 0 Gateway 192 168 1 254 XTRAMUS TECHNOLOGIES 13 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 2 1 Accessing NuTAP S61 Configuration Webpage To access NuTAP S61 s configuration webpage please open your web browser and m type in NUTAP S61 s IP address in web browser s URL field as shown in the figure B eten on the right side Please note that the IP address inputted here is only an example and may not apply to your network environment NuTAP S61 s configuration webpage only supports Microsoft mmm kk Internet Explorer 6 and NuTAP S61 s configuration webpage Ka might not display correctly if you re using other web browser The server 192 168 1 20 at NuTAP S61 requires a username and password A window will pop up after you entering NuTAP S61 s IP address Warning This server is requesting that your username and password be sent in an insecure manner basic authentication Please enter the User Name and Password for Nu TAP S61 s without a secure connection User name admin Password Trrm Remember my password configuration webpage
38. ble VLAN Tag IPES Error L CRC Error Pattern Check Description with Re direct Filter transmitted packets from specific Network Ports can be filtered and sentto the designated Monitor Parts Re direct Filter can be divided into Aggregate Segregate and Multi mirror Re direct Filter Re direct to Port MO Network Port Monitor Port AD MO Filter Network Port Monitor Fort AT hl Ap ili L EL 3 m m Protocol Direction The Direction field allows you to set the direction of the packet flow Re Direct to Monitor Port MO Re direct packets that meets the criteria from the Network Port to Monitor Port MO gt Re Direct to Monitor Port M1 Re direct packets that meets the criteria from the Network Port to Monitor Port M1 Please note that the figure displayed in the Description field will change according to the re direct setting you ve made here Protocol Re Direct All Packets Click the Re direct all packets check box to re direct all packets Protocol MAC Broadcast Multicast Unicast VLAN QinQ Double VLAN TAG CRC Error Protocol Network ARP IPv4 IPv6 ICMP IPCS Error Pattern Check Protocol Protocol TCP UDP FTP RTP Protocol Button m Apply Apply and save the changes you ve made on this page After making any settings L ao on this page you must click the Apply button or all changes will be lost XTRAMUS TECHNOLOGIES 63 E mail sales xtramus com W
39. c a0 a1 group 0 groupz1 baseaddress da sa vid mpls dip sip dp sp vlancos vid amp vlancos lt value gt command allows you to change the specific base address for NuTAP S61 s certain Network Port A0 A1 and the USC group Please refer to the table down below for command initial reference e DA Destination Address SIP Source IP Address e SA Source Address DP Destination Port baseaddress e VID VLAN ID SP Source Port e MPLS Multi Protocol Label VLANCOS VLAN Class of Switch Service e DIP Destination IP Address e VID amp VLANCOS VLAN ID and VLAN Class of Service For example to set the USC in source IP address of USC group 0 for Network Port AO to 192 168 1 1 please input the command counter setusc a0 group 0 baseaddress sip 192 168 001 001 The setusc a0 a1 groupzO groupz1 mode normal jitter command allows to change the mode for NuTAP S61 s certain Network Port A0 A1 and the USC group There are two modes available here mode e Normal The USC will run e Jitter The USC will run under under normal mode Jitter mode For example to set the mode of USC group 0 for Network Port AO to normal please input the command counter setusc a0 group 0 mode normal The setusc a0 a1 group 0 groupz1 enable disable command allows you to enable disable NuTAP S61 s certain Network enable disable Port A0 A1 and the USC group For example to enable USC group 0 for Network Port AO
40. cludes e all Select all e all Select all e all Select all e pattern Pattern Check e pattern Pattern Check e pattern Pattern e qinq QinQ Double e ging QinQ Double Check VLAN TAG VLAN TAG e ging QinQ Double e Vlan VLAN e vian VLAN VLAN TAG e rtp RTP Protocol e rtp RTP Protocol e vian VLAN e ftp FTP Protocol e ftp FTP Protocol e rtp RTP Protocol e ftp FTP Protocol For example to add UDP RTP and ICMP as Re direct Filter for packets flow from Network Port AO to A1 please input the command tapport a0toa1 red type udp rtip icmp SDFR stands for Self Discover Filtering Rules The tapport a0toa1 red sdfr da a da b da s sa a sa b sa s dip a dip b dip s sip a sip b sip s Parameter allows you to set the SDFR for Re direct Filter packets flow from Network Port AO to A1 The criteria available here includes e da a Destination Address A e da a Destination Address A e da b Destination Address B e da b Destination Address B e da s Destination Address Single e da s Destination Address Single e Sa a Source Address A e Sa a Source Address A e Sa b Source Address B e Sa b Source Address B e sa s Source Address Single e Sa S Source Address Single The Parameters should follow the format listed in the table down below e DA SA XX XX XX XX XX XX e DA SA XX XX XX XX XX XX For example to set SDFR for re directing packets with the destination IP address of
41. cription System configuration version user Display or clear counter information Display or setup TAP mode Display or setup monitor ports Display or setup TAP ports IP configuration address mask Clear screen Logout the current user NuTAP S61 gt _ Connected 00 00 06 Auto detect 38400 B N 1 CAPS Capture Print echo After logging in NuTAP S61 via HyperTerminal a NUTAP S61 Command Menu will be displayed showing NuTAP S61 s HyperTerminal commands Please see the table down below for brief descriptions of NuTAP S61 commands Command Alias Command Description The system command allows you to view NuTAP S61 s system information make system configurations and upgrade NuTAP S61 s firmware FPGA The counter command allows you to view NuTAP S61 s counter information and set USC Universal Stream Counter The mode command allows you to view NuTAP S61 s current running mode or change NuTAP S61 s running mode aggregate segregate multi mirror The monitor command allows you to view NuTAP S61 s Monitor Port MO M1 status or configure Monitor Port s settings The tapport command allows you to view NuTAP S61 s Network Port A0 A1 status or configure Network Port s settings The ip command allows you to view NuTAP S61 s current IP settings or configure these settings The cls command allows you to clear HyperTerminal screen The logout command allows you to log out For security issues it is
42. e tapport a0toa1 rate disable command will disable the Rate Control pattern enable disable NuTAP S61 supports two sets of Pattern Check group 1 and groupz2 The tapport a0toa1 pattern group 0 group 1 value mask enable disable Parameters command allows you to make settings for the Pattern Check The value sub command allows you to set the pattern value DATA for Pattern check For example to set the pattern value 00 00 00 00 00 00 00 00 for the Pattern Check Group 1 for packets flow from Network Port AO to A1 please input the command tapport a0toa1 pattern group 1 value 0000000000000000 The mask sub command allows you to set the pattern mask Byte Enable for Pattern Check For example to set the 3 byte of the pattern value enabled for the Pattern Check Group 1 for packets flow from Network Port AO to A1 please input the command tapport a0toa1 pattern groupz1 mask 00100000 Please note that the Parameter here should be 8 bit while 0 represents disable and 1 represents enable For example to enable the Pattern Check Group 1 for packets flow from Network Port AO to A1 please input the command tapport a0toa1 pattern group 1 pattern enable For example to disable the Pattern Check Group 1 for packets flow from Network Port AO to A1 please input the command tapport a0toa1 pattern group 1 pattern disable flowctrl The tapport a0toa1 flowctrl enable disable command allows you to e
43. ebsite www Xtramus com XTRAMUS B Re Direct Filter SDFR Protocol SDFR Session Result Rule Setting DA oo 00 00 00 00 00 pas foo 00 00 00 00 00 SA fpo 00 00 00 00 00 sA p0 00 00 00 00 00 vip Row JP Sf ew fi pp Rance Jf 0 0 0 0 DIPSf 0 0 0 sp Rog 0 9 9 9 sp 0 0 0 0 ppot ance Hros i 4 SPort Range 7 he spot Current Filter i Technical Terms DA Destination MAC Address SA Source MAC Address SIP amp DIP amp SPort VID VLAN ID SIP amp DIP amp DPort DIP Destination IP Address SIP amp DIP amp SPort amp DPort SIP Source IP Address VID amp SIP amp DIP amp SPort amp DPort DA 8 SA amp SIP amp DIP DA 8 SA 8 SIP amp DIP amp SPort amp DPort DA 8 SA 8 VID amp SIP amp DIP amp SPort amp DPort v anme raricie DPart Destination Port SPart Source Port gt l Apply SDFR Self Discover Filtering Rules is a technology that makes packet capturing filtering over Ethernet easy and convenient Each filter is independent and can be activated in any combinations DFR Choosing SDFR Parameters You can choose the criteria with the check boxes The SDFR parameters available here includes gt DA Destination MAC Address gt DIP Destination IP Address gt Sport Source Port SA Source MAC Address gt SIP Source IP Address gt VID VLAN ID gt DPort Destinati
44. et here will be used as SDFR parameters The Current Filter field displays the settings you ve made while the Technical Terms field displays the explanations for DA SA DIP and SIP DFR Button apply XTRAMUS TECHNOLOGIES 60 Apply Apply and save the changes you ve made on this page After making any settings on this page you must click the Apply button or all changes will be lost E mail sales xtramus com Website www Xtramus com ATRAMUS C Capture Criteria Result Frotocol BDFR Result CRO error DA Si amp SIP DIP 4 DA Range OO O0 00 00 00 00 FF FF FF FF FF FF Si Range 11 11 11 11 11 11 22 22 22 22 22 22 DIP Range 192 188 1 1 192 168 1 100 SIP Range 192 168 10 1 192 168 10 100 Result The Result page will display the settings you ve made in Protocol and SDFR pages XTRAMUS TECHNOLOGIES 61 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 5 3 Re Direct Filter Re direct Filter Re direct ta Port MO Network Port Monitor Port AD MO Filter Network Port Monitor Port AT I hil 1 With Re Direct Filter transmitted packets from specific Network Ports can be filtered and sent to the designated Monitor Ports Re Direct Filter can be divided into Aggregate Segregate and Multi Mirror Re Direct Filter Mode Captured and sent Monitor Port MO to ONE designated Aggregate Transmitted packets from Monitor Port Network Port AO t
45. etwork Port AQ Af 53 3 2 6 Monitor Port ti e 53 3 3 System Status Overview ik waw ta bk wt kt kw e to l a ka a aa e a a e a kk n ke e a 54 3 4 Test Running Status lcon 111 kanna aaa a aaaaaaaaaaataasasonasoaaonsosannanaaannnnannnnnn 54 3 5 Netw rk Port Seting ew soxiesie an oui da wit ti E 55 SEUN ME OAK ONE jii 56 A Forwarding Filter Protocol eee Leee eee eere eren e enne nnne nnn nnn 56 B Forwarding Filter SDFR leeee iere iieeeelieeee esee n nnn n nnn h nnnm n nhan nnn nan 57 C Forwarding Filter RS Miccccccicevewesscdeccesscovetenicadwsucsiewcdcaueswesssusaedevovvesecdstveescuexsmawestexens 58 3 5 2 Capture erg T e 59 A Capture Criteria Protocol 1 11er cernere eere rer rennen aanannannannanannannanannnn 59 B Capture Criteria SDFR dcc ves souye nu tu ew ka ai cuc wo ri pon e ana kan pd RRFE RUE THREE CERE esseye 60 C Capture Criteria Result ass s oeas ao vinn t k okiyk ka k k kok FREUD RRYEGE UE a sik an f n aa os AA b kiba PUR KRREC mnnn 61 SEDED MOU NECL PINION e ki ki kai ko a l e a pal kek a ki l ak n a ka TELE 62 A He Direct Filter PFOIOCOlL sca douce oi on ai a n if n ek eras ne ke ko ak n n jn m 63 B Re Direct Filer SDFR
46. file saved on your PC The firmware FPGA file Po should be in the format of gt bin ka Click Open after you ve chosen the file My Computer My hc File name NuTAP S61_RTC_v0 9b008 Places Files of type bin Cancel Li NuSet MiniTAP x File paNuTAP S61 Firrnware amp PPGAINUTAP S61_ AT v0 9600BIMNuT System Information Model NuTAF S61 Hardware Version WESOD Firmware version v0 8b008 FPGA Version vi ObODS Upgrade Cancel 4 Click Upgrade button to start upgrading NuTAP S61 NuTAP 311 s firmware XTRAMUS TECHNOLOGIES 50 E mail sales xtramus com Website www Xtramus com XTRAMUS zi 5 Please note that the upgrading process will set all settings to default Click YES to continue the upgrading process Please note that upgrading will set all settings to default m Click YES to continue upgrading or click WO ta cancel 6 NuSet MiniTAP will start upgrading The device s power must be ALWAYS ON during the upgrading process firmware Please note that during this Contd process NuTAP S61 NuTAP 311 s power must be ALWAYS on System Jpqgrading will take 1 minutes while upgrading Upgrade Upgrade completed 7 Upgrade complete NuTAP S61 Please restart your device by powering it off and power it back NuTAP 311 will reboot after upgrading firmware Terminal Web The Terminal Web Connection function will open your web browser and
47. filter of Layer 2 Destination MAC Address DA Source MAC Address SA Layer 3 Destination IP Address DIP and Source IP Address SIP Each filter is independent and can be activated in any combinations DFR Choosing SDFR Parameters You can choose the criteria with the check boxes The SDFR parameters available here includes gt DA Destination MAC Address gt SA Source MAC Address SIP amp DIP and DA amp SA amp SIP amp DIP DFR Rule Setting gt DIP Destination IP Address gt SIP Source IP Address As mentioned above each parameter is independent and can be activated in any combinations of DA SA SIP DIP DA amp SA DA amp SIP DA amp DIP SA amp SIP SA amp DIP D pa O sa 7 sp pip DA 4 SA DA a SIP DA amp DIP 7 sA a SIP 4 amp DIP SIP amp DIP DA amp SA amp SIP amp DIP The Rule Setting field allows you to set and input the value of DA SA DIP and SIP The value of SDFR parameters can be set as Single Pair and Range The following descriptions will use DA as example DA Singe n0 00 00 00 00 00 Single A single value will be used as SDFR parameter DA Pair no 00 00 00 00 00 er n0 00 00 00 00 00 Pair Two values will be used as SDFR parameters D Range 00 00 00 00 00 00 lt DAS 00 00 00 00 00 00 DFR Current Filter Technical Terms Range Values within the range of the two values s
48. h Load Existing Config Profile function located on the Menu Bar A prompt pop up window will ask if you are sure to exit NuSet MiniTAP Click YES to exit NuSet MiniTAP or click NO to cancel XTRAMUS TECHNOLOGIES 45 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 1 2 Config Contig Network Pork AD Network Pork A1 Monitor Part MO Monitor Part Mi Port Configuration System Configuration Function Descriptions Config Network Port A0 A1 The Network Port A0 A1 function located on the Menu Bar allows you to make settings regarding to Network Port A0 A1 on the Main Display Screen For more detail information please refer to 3 5 Network Port Settings on page 21 Monitor Port The Monitor Port A0 A1 function located on the Menu Bar allows you to make settings regarding to Monitor Port AQ A1 on the Main Display Screen For more detail Mo information please refer to 3 6 Monitor Port Settings on page 33 You can make settings regarding to NuTAP S61 NuTAP 311 s Network Port A0 A1 and Monitor Port MO M1 with the Port Configuration function located on the Menu Bar x You can set the connection rate for Network Media Type Flow Control Rate Control Ports and Monitor Ports with the Media Type P Auta menu tab C Force 10M Full gt Auto All Set all Network Ports and iii Monitor Ports as auto negotiation Force 10M Full Set all Network Ports and Monitor Ports to
49. hat meet the criteria by e Connecting NUTAP S61 s Console Port to a PC with NuSet MiniTAP installed via a RJ45 to USB cable e Connecting NUTAP S61 s Monitor Port MO or M1 depending on your settings to a PC with other network TAP software installed via an RJ45 cable E mail sales xtramus com XTRAMUS TECHNOLOGIES 9 Website www Xtramus com XTRAMUS 2 2 Hardware Installation for NuTAP S61 Management There are 3 different ways to connect NUTAP S61 to your PC and configure view its settings Connecting via RJ45 to USB Cable PC s USB Port Connected via RJ45 to USB Cable NuTAP S61 Console Port PC Running bos NuSet MiniTAP Connecting via RJ45 Cable Network PC s Network Interface Card NIC C Connected via RJ45 to Serial Cable NuTAP S61 Console Port PC Runni Console A HyperTerminal n XTRAMUS TECHNOLOGIES 10 By connecting NuTAP S61 s Console Port to PC s USB Port via RJ45 to USB cable you can configure view NuTAP S61 s settings with NuSet MiniTAP installed on your PC Also the RJ45 to USB cable will serve as NuTAP S61 s power source as well By connecting NuTAP S61 and PC to the same network you can configure view NuTAP S61 s settings with the web browser installed on your PC To access NuTAP S61 s configuration webpage with your PC s web browser please connect one of NUTAP S61 Network Port A0 A1 or Monitor Port MO M 1 to the network which your PC is connected to Plea
50. ics here as well For more detail information please refer to 3 7 Counter Report on page 34 Universal Stream Counter USC Report Each of NuTAP S61 NuTAP 311 s Network Port supports two sets of Universal Stream Counter USC The Universal Stream Counter USC Report function located on the Menu Bar allows you to view USC statistics on the Main Display Screen You can save the USC statistics here as well For more detail information please refer to 3 8 Universal Stream Counter USC Report on page 38 Capture Network Port A0 A1 Packets Capture Network Port AD Packets T Ceea op hide Feakime Moda 10 65 di d f r P Do 4F I l The Capture Network Port A0 A1 Packets function located on the Menu Bar allows you to capture packets flowing through Network Port A0 A1 NuSet MiniTAP has two different modes available for capturing packets C Capture and Stop Mode Real time Made Capture and Stop Mode NuSet MiniTAP will capture and store packets in NuTAP S61 NuTAP 311 s memory buffer The captured packets will be displayed when you stop packet capturing Please note that only 8 packets will be stored to the memory buffer at the same time and old packets stored in the memory buffer will be replaced by new captured packets Real time Mode NuSet MiniTAP will capture all packets that meet the criteria and display them in a real time fashion E ihl D m fa Open Save Start Stop Setting You can control
51. iniTAP File Config Report Service Languages Help B iz E EE Reconnect Counter LISC cap AND Em Al Network F Pork 40 Yer Part 41 Monitor Port MO Monitor Pork M1 System Br LL E Es MuTAP S61 Er 9 System Information 0 4 SIN OUNUTAPS6101 Ni MAC D0 22 A2 2D 00 00 E es Network Port AD Status E o Connection Mode Auta All E o Link Status 5 Link Link down Q Speed MA O Flow Control Off Rate Control Off B EN Neben Pot Al Status C E o Connection Mode Auto All Er 6 Link Status E j 5 Link Link down IB Tee TP Mi a IM f P X f VY 75 J 0 Rate Control Of Network TAP TUR Multi Redirect and Smart Filtering Rule B E Monitor Part MO Status EB o Connection Mode Auto All i l o Link Status ff Link Link down JQ Speed Ni Mi Flow Control Of Br Ed Monitor Port M1 Status Br OY Connection Mode Auto All EB Link Status j 9 Link Link down LO Speed Nid LO Flow Control Off Connected 7 F NuTAP S60 310 Utility Functions Overview The Menu Bar allows you to make settings about test criteria A Menu Bar view save test log change language displayed and update firmware FPGA The Quick Launch Buttons allow you to reconnect your PC to B Quick Launch Buttons NuTAP S60_ 310 Utility open save test logs and switching Main Display Screen display mode Status of Network Port AO A1 Monitor Port MO M1 and NuTAP S61 NuTAP 311 system overview
52. ion Please follow the steps down below to install NuSet Mini TAP NuSet MiniTAP Installation 1 Double click NuSet MiniTAP installation program and start the installation process Preparing to Install NuSet Mini LAP v1 bU Setup is preparing the InstallShield Wizard which will quide you through the program setup process Please wait Checking Operating System Version SSS 2 InstallShield Wizard is starting to install NuSet MiniTAP If you would like to cancel installation click Cancel XTRAMUS TECHNOLOGIES 39 E mail sales xtramus com Website www Xtramus com XTRAMUS NuSet MiniTAP Installation m SuSet MiniTAP 1 0b000 InstallShield Wizard Welcome to the InstallShield Wizard for NuSet MiniTAP v1 0b000 The InstallShield R Wizard will allow vou bo modify repair or remove MuSet MiniTAP wi ObODO To continue click Next 3 Click Next to continue installation p NuSet MiniTAP 1 0b000 InstallShield Wizard License Agreement Please read the following license agreement carefully End User License Agreement IMPORTANT NOTICE This is a license agreement between you either an individual or a single entity and Atramus Technologies Atramus 4 Click l accept the terms in the license agreement and click Next to continue Before installing ar using this software please read the following license te
53. it wi ta ot l al l a ki ai a ea ka ta a ki a a pk e kk a ke a l UE 64 C Re Direct Filter SESSION any et wa wi ewe poke e oue de yi ale ti ma saa kk ok ae ank n ana Go nnmnnn kana s man awa poo ke 65 D Re Direct Filter Result Leeeieee serere ee reee eene eese enne n nennen nnn n nnns 66 3 6 Monitor Port SOLUTIO bte ai aze aki kwa ai air ia w ob a kk oi kl ai e a kk ok ki kn n pi a a dp 67 Jal COUNTER EDOR ei ka kw ki ta t en l of e te e lk a e ae e n e a a a a e ke da ak a Bi ban 68 3 8 Universal Stream Counter USC Report 1 e eeeeeeeeLeeee leeren esee enn nanus 72 XTRAMUS TECHNOLOGIES 38 E mail sales xtramus com Website www Xtramus com XTRAMUS 1 Installing Uninstalling NuSet MiniTAP NuSet MiniTAP is a GUI graphic user interface utility software for setting test criteria and system management NuSet MiniTAP supports NUTAP S61 and NuTAP 311 When NuTAP S61 NuTAP 311 is connected with PC via its RJ45 to USB cable you can set test criteria save view testing results and upgrade firmware FPGA with NuSet MiniTAP However before using NuSet MiniTAP s features and functions you have to install it on your PC first Both NuTAP S61 and NuTAP 311 s drivers are contained in NuSet MiniTAP The required drivers and NuSet MiniTAP will be installed at the same time Please note that DO NOT connect your NuTAP S61 NuTAP 311 to the PC before the installat
54. ld the Reset Button for 4 seconds NuTAP S61 will reset all settings to default after a long beep Reset Button Back Panel amp Ports NuTAP S61 Ports Console ARA NuTAP S61 Description Back Panel amp Ports UTP Port for Firmware FPGA Upgrading Configuration Setting and NuTAP S61 Power Console Port Supply x Network Port These two 10 100 Mbps Full Ethernet UTP Network Ports can transmit receive test A0 A1 packets generated by NuTAP S61 Monitor Port These two 10 100 Mbps Full Ethernet UTP Monitor Ports can monitor capture test MO M1 packets transmitted from Network Ports x Note When using Console Port as NuTAP S61 s power source please use the RJ45 to USB cable that comes with NuTAP S61 package Extending the length of RJ45 to USB cable might cause NuTAP S61 power insufficient XTRAMUS TECHNOLOGIES 8 E mail sales xtramus com Website www Xtramus com XTRAMUS 2 NuTAP S61 Application Example 8 Hardware Installation 2 1 Hardware Installation for Network Tapping Network A Network B Connected to Network Port A0 Connected to Network Port Al Packet Flow Packet Flow PC connected to Console Port PC connected to Monitor Port via EJ45 to USE cable via RJ45 cable Console Xu PC with Network T AP PC with HuSet HiniTAP software installed installed As the example shown in the figure above NuTAP S61 allows you to perform network tapping You can monitor filter packets t
55. ll statistics displayed in the table XTRAMUS TECHNOLOGIES 20 E mail sales xtramus com Website www Xtramus com ATRAMUS 3 2 5 NuTAP S61 Configuration Webpage Maintenance Four options are available in the Maintenance configuration webpage Save Changes System Reboot Factory Defaults and Logout Save Changes save Changes The device configuration will be saved to NV KAM If you don t save the setting you ve made via NUTAP S61 s configuration webpage all settings will be erased after rebooting Nu TAP S61 Please click the Save button to save the settings to NuTAP S61 s NV RAM System Reboot System Reboot System reboot Warning System will reboot All unsaved data settings will be lost after system reboot ystem Reboot You can reboot NuTAP S61 by clicking the Reboot button Please note that all Reboot unsaved settings will be lost after system reboot Factory Defaults Restore Default Settings Restore Default Settings Warning System will restore all settings to default All unsaved data setting will be lost after restore to default setting You can set all NuTAP S61 s settings to the default value by clicking the Restore Restore button Please note that all unsaved data settings will be lost after restoring Nu TAP S61 s settings to default value XTRAMUS TECHNOLOGIES 24 E mail sales xtramus com Website www Xtramus com ATRAMUS Logout Logout Success
56. llision o Tx Excession Collision l7 Rx Dribble Bit gt Rx Alignment Error Show Chart Network Port Monitor Port Rabe a i E Error amp Loss Packet gt E E Total 2 Parts Link Up Link Up 100M Full 100M Full Accessing Counter Report Control Buttons These buttons allow you to save the counter report start stop updating counter report clear all statistics view charts and switch to display Monitor Port Network Port Main Display Window You can view counter statistics here in this section Please see the sections down below for detail information regarding to Counter Report XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com 68 XTRAMUS Bg 9 000 M EA Em cave lipdate Clear Hide Show Chart Network Port Monitor Port Report Control Buttons Descriptions The Save button allows you to save the current Network Port and Monitor Port counter reports Save to Microsoft Excel amp format files The Update button allows you to start stop updating statistics displayed in the Main Display Update Window jin Clear The Clear button allows you to clear all statistics displayed in the Main Display Window 4M The Hide button allows you to hide all Network Ports and Monitor Ports TX Rx statistics as well Hide las fold all tree style tab statistics in the Main Dis
57. mand allows you to reboot NuTAP S61 Please note that all unsaved settings will be lost after rebooting XTRAMUS TECHNOLOGIES 27 E mail sales xtramus com Website www Xtramus com ATRAMUS B NuTAP S61 HyperTerminal Command counter Command Descriptions counter The counter show command allows you to view all Nu TAP S61 s counter report as well as hardware temperature You can also add additional commands behind the counter show command as listed down below The counter show usc a0 a1 groupzO groupz1 command allows you to view NuTAP S61 s USC Universal Stream Counter report of its Network SOM Port A0 A1 and the USC group For example to view the USC in USC usc group O for Network Port AO please input the command counter show usc a0 group 0 configure The counter show configure command allows you to view USC s settings clear The counter clear command allows you to clear all counters refreshtime The refreshtime show command allows you to view the refresh time for the report The refreshtime set command allows you to set the refresh time in seconds for the report show set counter setusc The counter setusc command allows you to configure NuTAP S61 s USC Universal otream Counter settings Please refer to the sections down below for detailed descriptions Also to view command lists for USC settings you can input counter help setusc The counter setus
58. mation acquired this way may be too vast and complicated for pinpointing the possible cause of network product problems Unlike these common packet analyzers or sniffers mentioned above Universal Stream Counter USC offers real time statistics of network events during packet monitoring and capturing Each of NuTAP S61 s Network Port contains two sets of Universal Stream Counters USC 0 1 and statistics about Line Rate Packets Bytes Broadcast Multi cast IP Check sum Error and CRC Error of all DA Destination Address can be viewed here in this page Refresh Clear Universal Stream Counter 0 for Port AO xx xx D0 00 00 01 mao0204p m n p p p J max00000009 foks o max00000004 foks bo b max00000005 os o b 1 wma pos p p pbp p p e h n p JoJo S mac00000009 Kms b b max009000094 Kws ma00000098 okes b p b b mac0o900000 Yo o 4 b max00000000 okes o b b b b px90 00 00 00 0E foks o Q0 p b b mac0o900009F foks oo max00000010 okes o b j b mac0000904 okes J CO on es p 8 B p n Xx xx D0 00 00 13 OKbps 0 0 USC Counter Refresh Refresh the configuration webpage and update the latest statistics Clear Clear a
59. monitor configuration option are listed down below header e DA SA XX XX XX XX XX XX e DIP SIP XXX XXX XXX XXX e ID XXXX e DPORT SPORT XXXX The monitor mO m1 portzall header mode command allows you to set the combinations of headers that will be added to packets to from designated mode Monitor Port MAC ID Timestamp IP Port Fragment For example to add the header with ID and IP to packets to from Monitor Port MO please input the command monitor m0 header mode id ip The monitor m0 m1 port all header reset command allows you to reset all settings made to the specific Monitor Port For example to reset all settings done for Monitor Port MO please input the command monitor m0 header reset reset XTRAMUS TECHNOLOGIES 29 E mail sales xtramus com Website www Xtramus com ATRAMUS E NuTAP S61 HyperTerminal Command tapport Command Descriptions tapport The tapport show command allows you to view information regarding to Nu TAP S61 show Network Ports media types and Forwarding Filter Re direct Filter Capture Criteria settings The tapport set mediatype nway 10f 100f allows you to set NuTAP S61 Network Ports media type set e Nway Auto Negotiation e 10F 10 Mbps Full 100F 100 Mbps Full For example to set NuTAP S61 Network Ports to auto negotiation mode please input the command tapport set mediatype nway Setting Forwarding Filter fwf
60. n v1l O0bO005 Firmware Version vO 9b0077 Management Port Puos oni IP Address 192 168 1 20 1255 255 255 0 192 168 1 1 Network Port Link Down Link Down wo omm bpage Overview The Setting Options contains options for NuTAP S61 s settings information and statistics which can be divided into e System You can set NUTAP S61 s basic system settings or view system information with this option Setting Options Statistics You can view NuTAP S61 s counter Universal otreams Counter reports with this option Maintenance This option allows you to save system settings reboot NuTAP S61 and reset all NuTAP S61 s settings to default value The Main Display Screen displays the system information Main Display Screen ctwork tapping statistics and detail configuration options XTRAMUS TECHNOLOGIES 15 E mail sales xtramus com Website www Xtramus com ATRAMUS 3 2 3 NuTAP S61 Configuration Webpage System System Information System Information MAC Address DOZ AZ 2 DOUDOU FPGA Version v1 00005 Firmware Version vO GbOU7 Management Port Network Port mo OM ul System Information displays NuTAP S61 s system information including System Information MAC Address NuTAP S61 s MAC address FPGA Version NUTAP S61 s current FPGA Field Programmable Gate Array version Firmware Version NuTAP S61 s current firmware version Management Port IP Mode
61. nable or disable Flow Control flowctrl XTRAMUS TECHNOLOGIES 33 E mail sales xtramus com Website www Xtramus com ATRAMUS E NuTAP S61 HyperTerminal Command ip Command Descriptions ip show The ip show command allows you to view information of Nu TAP S61 s IP configuration status The ip status command allows you to view information of NUTAP S61 s IP status mode dhcp The ip mode dhcp command allows you to set NuTAP S61 s IP acquiring mode to DHCP allowing NuTAP S61 to acquire IP automatically from DHCP server The ip mode static command allows you to set NuTAP S61 s IP acquiring mode to Static allowing you to set IP Subnet Mask Gateway IP manually Static The ip address IP Address command allows you to set NuTAP S61 s IP address For ip address example to set NuTAP S61 s IP address to 192 168 1 20 please input the command ip address 192 168 1 20 mask The ip mask Subnet Mask Address command allows you to set NuTAP S61 s subnet mask address For example to set NuTAP S61 s subnet mask address to 255 255 255 0 please input the command ip mask 255 255 255 0 The ip gateway Gateway Address command allows you to set NuTAP S61 s gateway gateway address For example to set NuTAP S61 s subnet gateway address to 192 168 1 254 please input the command ip gateway 192 168 1 254 F NUTAP S61 HyperTerminal Command cls Command Descripti
62. ng the End Time scroll down menu and selecting a time opip Oe 15 47 53 i i i 20101002 15 4756 listed here allows you to view the Bar Chart of that time XTRAMUS TECHNOLOGIES 70 E mail sales xtramus com Website www Xtramus com XTRAMUS Counter Report 8 e m A Em m Save Update Clear Hide Show Chart Network Port Monitor Port Network Port t Total 2 Ports Link Status Link Up Link Up Speed 100M Full 100M Full Tx Packet Tx Byte Tx Line Rate Mbps Tx Utilization Tx Pause Rx Packet ER Rx Byte Rx Line Rate Mb Network Port salad Mbps Rx Utilization Rx Pause Cl Collision Tx Collision ty Single Collision F7 Tx Multi Collision Tx Excession Collision a Error amp Loss Packet Rx Dribble Bit iss Rx Alignment Error Ee The Network Port button allows you to view Counter Report of NUTAP S61 NuTAP 311 s Network Ports Counter Report 8 o m d A Em Save Update Clear Hide Show Chart Network Port Monitor Port Monitor Port Total 2 Ports Link Status Link Up Link Up Speed 100M Full 100M Full Tx Packet Tx Byte Tx Packet Rate pps Tx Line Rate Mbps Tx Utilization 6 Tx Pause H Rx Byte Rx Packet Rate Monitor Port SE loki Rx Line Rate Mbps Rx Utilization Rx Pause A Collision Tx Collision Packet 0 7 Tx Collision Times 0 E Layer 2 Packet Counters F7 Rx Broadcast 65 145
63. nnn nnnm 39 2 NuS t MINITAP OVGFVIGW vi ai os bio it kk a ak l pk aa e P a e VAL CR a EQ pk kk a a QUERER an pa a n NUS NUR nennen 43 2 1 Starting NuSet MiniTAP stt utas au wou s ion ia kn ok kk wi a a ka a a a ak kk ko a a bd w a pa aw ab EE 43 2 2 NuSet MiniTAP Main Window Overview 1 ee eeeeer iier nee e nennen nnne nhan nnn uana 44 3 NuSet MiniTAP Functions 11 1111 e aa aa aaa aaa aaa aaaaaesasasestsosasteooasoosossonosoasonanaaanannnan 45 SWINE MES 45 AMI LI a ki 45 uei 46 SE EM e 48 ILA SOU VG L et kit li ai ott 50 SES eed OU AO eke tt di wow ia ia m w kai a ei l ai a tv a a n e a a a t ia kk a ek a a e n a e S 51 ZENONE ke tet awa k ba kek k ii ke ta E a e n 51 3 2 Quick Launch Buttons 6 s900826k sastte si aaetiaoa as SERIEM MENSES n bn kaa ao UN REIS kon sea ek bk IMS pup FE AUE 52 PUMP Legi kt k i ki ki tj ak e kk a a e l kt kk a ke ke e a a l ke e e pr ki n ni 52 Jid 2 COUNT oa E 52 3 2 3 USC Universal Stream Counter 1 esee eee eene eene enean nnne n nana nns 52 xS EG AO A 52 3 2 5 N
64. nt any improper operation or in irregular environment may possibly cause this product NOT function well For detailed terms please contact your local dealer Contact Information Xtramus Technologies E mail sales xtramus com Website www xtramus com Tel 886 2 8227 6611 Fax 886 2 8227 6622 XTRAMUS TECHNOLOGIES 36 E mail sales xtramus com Website www Xtramus com XTRAMUS Revision History Date Version A hHistry o 2010 09 26 First draft version 1 Page 43 change NuTAP S61 installation figures and related descriptions Page 53 changing title descriptions regarding to Monitor Port MO M1 Page 56 change descriptions regarding to Filter All Packets Page 57 60 correct typos regarding to Rule Setting Page 63 change descriptions regarding to Re direct All Packets Page 64 change descriptions regarding to VLAN ID Page 69 change descriptions regarding to Line Mode Page 69 change column title to Report Control Buttons Descriptions Page 70 change descriptions regarding to Bar Mode Page 71 change column title to Accessing Universal otream Counter USC Report 2010 12 13 XTRAMUS TECHNOLOGIES 37 E mail sales xtramus com Website www Xtramus com XTRAMUS Table of Contents ONY ON Vini a ki tt E Um 36 PROVISION PIS LON RTT TL 37 1 Installing Uninstalling NuSet MiniTAP e Leeeee eL eeeee ree eeee enne nennen
65. o A1 or the other way around that meet the criteria set in pon Re Direct Filter will be captured and Ww transferred to ONE designated Monitor Network Port Packet Flow Network Port Port AD A1 Captured and transferred to ONE Monitor Port MO designated Monitor Port judging by the direction of packet transmitting flow Segregate Transmitted packets between Network Port AO and A1 that meet the p criteria set in Re Direct Filter will be a Packet Flow ax captured and transferred to ONE Network Port Network Port esignated Monitor Port judging by the AO A1 direction of packet transmitting flow AO AlorA1 AQ Monitor Port M1 Monitor Port MO M1 Captured and transferred Multi Mirror Transmitted packets from to BOTH Monitor Ports Network Port AO to A1 or the other way around that meet the criteria set in Re Direct Filter will be captured and transferred to BOTH Monitor Ports Packet Flow Network Port AQ A1 Network Port XTRAMUS TECHNOLOGIES 62 E mail sales xtramus com Website www Xtramus com ATRAMUS A Re Direct Filter Protocol Forwarding Filter Capture Criteria Re direct Filter Pattern Check Protacal SDFR Session Result Direction v Re directto Monitor Pot MO Re directto Monitor Pat bil Re direct all packets MAC gt Network Fratacal Broadcast ARP TCP Multicast AP UDP Unicast A6 PAP T VLAN ICMP LIN GinG Dou
66. oadcast Multicast Unicast VLAN QinQ Double VLAN TAG CRC Error Protocol Network ARP IPv4 IPv6 ICMP IPCS Error Pattern Check rotocol Protocol TCP T Protocol Button me Apply Apply and save the changes you ve made on this page After making any settings isnt on this page you must click the Apply button or all changes will be lost XTRAMUS TECHNOLOGIES 56 E mail sales xtramus com Website www Xtramus com XTRAMUS B Forwarding Filter SDFR Protocol SOFR Result IZ Rule Setting ba i D sa 7 sp pe TT DA a SA DA 4 SIP pw amp pip SA 4 SIP SA amp DIF 7 SIP amp DIP DA amp SA amp SIP A DIP r Current Filter 7 Technical Terms DA Destination MAC Address SA Source MAC Address DIF Destination IP Address SIF Source IP Address SDFR Self Discover Filtering Rules is a technology that makes packet capturing filtering over Ethernet easy and convenient SDFR parameters include filter of Layer 2 Destination MAC Address DA Source MAC Address SA Layer 3 Destination IP Address DIP and Source IP Address SIP Each filter is independent and can be activated in any combinations DFR Choosing SDFR Parameters You can choose the criteria with the check boxes The SDFR parameters available here includes gt DA Destination MAC Address gt SA Source MAC Address
67. om ATRAMUS Revision History Date Version A History n 2010 09 26 First draft version 2010 10 28 Remove Draft watermark 2010 12 13 Correcting typos errors in NuSet MiniTAP section For more detail please refer to NuSet MiniTAP Revision History Change Xtramus logo on page 1 Apply the new USM format 2011 07 28 1 2 Page 6 changing UTP Port to RJ45 Port Page 6 changing 32 bit to 48 bit Page 6 adding multi language feature XTRAMUS TECHNOLOGIES 3 E mail sales xtramus com Website www Xtramus com XTRAMUS Table of Contents PON CW OR E s 2 PROVISION PUES COU M 3 1 NuTAP S61 Overview saree 5 1 1 General Description Of NUTAP S61 ccccceeesesseesceesseeeccenseeeecenseeseoeseeeseoenseessonnseesooees 5 1 2 Key Features of NUTAP SO 1 is feet ukit aw ou wit kw ks ka aka w ik w ak kl a e kk n kk pa a a a a e w 6 1 3 NuTAP S61 Panel Function Overview 1 eeceee eee reeee ree ieee enne nennen hann 7 2 NUTAP S61 Application Example amp Hardware Installation 9 2 1 Hardware Installation for Network Tapping eere 9 2 2 Hardware Installation for NuTAP S61 Management
68. om Website www Xtramus com XTRAMUS 3 6 Monitor Port Setting You can configure filtering capture criteria and pattern check for Monitor Port MO M1 in the Port Config Monitor Port screen There are two ways to access Port Config Monitor Port Accessing Port Config Monitor Port T NuSet MiniTAP File Config Report Service Languages Help Network Port AD 3 3 l l l e ela Cap A0 Cap Al Network Port AO Network Port A1 BE e Click Monitor Port MO M1 located on Config Monitor Pork MO ji Monitor Port M1 Port Config Monitor Port MO in the Menu Bar Port Configuration System Configuration psi Header Click the Monitor Port MO M1 button located on Quick Launch Buttons Port Config Monitor Port MO Port Config Monitor Port MO Add Header DASA IPHeader Time Stamp UDP Header VLAN TAG IPFragment The Monitor Port setting page allows you to set the headers that you would like to add to packets transmitted from Monitor Port MO M1 NuSet MiniTAP supports headers including DA SA Time Stamp VLAN TAG IP Header UDP Header and IP Fragment These headers are corresponding with the value inputting field down below the Monitor Port setting page as show in the table here gt DA SA Destination Source MAC Address P Header DIP Destination IP Address and Time Stamp N A However a timestamp SIP Source IP Address header will be added to the packets UDP Header
69. on Port As mentioned above each parameter is independent and can be activated in any combinations of DA SA VID SIP DIP SPort DPort DA amp SA DA amp SA amp VID DA amp SIP DA amp DIP SA amp SIP SA amp DIP SIP amp DIP SIP amp SPort SIP amp DPort DIP amp SPort DIP amp DPort SIP amp DIP amp SPort SIP amp DIP amp DPort SIP amp DIP amp SPort amp DPort VID amp SIP amp DIP amp SPort amp DPort DA amp SA amp SIP amp DIP DA amp SA amp SIP amp DIP amp SPort amp DPort and DA amp SA amp VID amp SIP amp DIP amp SPort amp DPort DFR Rule Setting The Rule Setting field allows you to set and input the value of DA SA VID DIP SIP DPort and SPort The value of SDFR parameters can be set as Single Pair and Range The following descriptions will us DA as example DA Singe v p5 00 00 00 00 00 Single A single value will be used as SDFR parameter pa Par v oo 00 00 00 00 00 or 95 00 00 00 00 00 Pair Two values will be used as SDFR parameters m Range e 00 00 00 00 00 00 EXE 06 00 00 00 00 00 Range Values within the range of the two values set here will be used as SDFR parameters DFR Current Filter Technical Terms The Current Filter field displays the settings you ve made while the Technical Terms field displays the explanations for DA SA VID DIP SIP DPort and SPort DFR Button mue Apply Apply and sa
70. ons cls els The cls command allows you to clear HyperTerminal screen G NuTAP S61 HyperTerminal Command logout Command Descriptions logout logout The logout command allows you to log out of NUTAP S61 s HyperTerminal configuration session XTRAMUS TECHNOLOGIES 34 E mail sales xtramus com Website www Xtramus com NuSet MiniTAP User s Manual USM Ver 1 1 XTRAMUS Foreword Copyright Copyright 2010 Xtramus Technologies all rights reserved The information contained in this document is the property of Xtramus Technologies No part of this publication shall be reproduced stored in a retrieval system or transmitted in any form or by any means without the prior written permission of Xtramus Technologies Disclaimer The information contained in this document is subject to change without notice and does not represent a commitment on the part of Xtramus Technologies The information in this document is believed to be accurate and reliable However Xtramus Technologies assumes no responsibility or liability for any errors or inaccuracies that may appear in the document Trademarks NuSet MiniTAP is a trademark or registered trademark of Xtramus Technologies All other trademarks and registered trademarks are the property of their respective owners Warranty Xtramus Technologies warrants for the hardware provided along with this document under proper usage and conditions in normal environme
71. packet capturing with the control buttons located above Capture Settings X gt Open Open a pcap file and view NH captured packets with NuSet MiniTAP TAS SO IT Save Save the captured packets asa bu notice packet drops you can try to increase this file in the format of gt pcap Start Stop Start Stop packet capturing Setting A Capture Settings window LEM will pop up allowing you to set memory buffer size KB Buffer Size MIES Kilobytes EB XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com 48 XTRAMUS Function Descriptions Report Capture Network Port A0 A1 Packets Contd Lengh wth cR ba sa van Protocol DP IP CO Co On 4 co no AB BA A5 558 55 5 AB 5A AD SA AS SA AD BA AS SA AS BA AB5 5A A5 5A A5 5 AB 5A AD SA A5 5 AB 5A A5 54 55 5 AB 5A A5 5A A5 5 AB 5A AB SA A5 5A AB 5A A5 5 A5 5 AB 5A A5 5A A5 5 ABb 5A 55 5A A5 5 ABBAAS SAAS SA AB5 5A AS SA AS SA AD BA AS SA A5 5 AB 5A A5 5A A5 5 AD BA AD SA A554 Item Name El Ethernet II Destination A5 5A 45 5A A5 5A Source A5 5A A5 5A A5 5 Type 0x4554 00000000 AS SA AS SA AS SA AS SA AS SA AS SA AS SA AS SA Z 00000010 AS SA AS SA AS SA A5 SA AS SA AS SA AS SA AS SA Z 00000020 AS SA AS SA AS SA AS SA AS SA AS SA A2 00 07 OO Z 00000030 00 00 SF 06 BB 99 34 3D AS SA AS SA E 00 6D 51 Fields down below display informa
72. play Window 4 The Show button allows you to show all Network Ports and Monitor Ports TX Rx statistics as Show well as unfold all tree style tab statistics in the Main Display Window The Chart button allows you to view Network Port s Counter Report Chart on a pop up Chart window There are three different display modes for Counter Report Chart Line Pie and Bar Update Start Stop updating Counter Report Chart ay lis Line Switch the chart display mode to Line Update Line Pie Bar Mode Pie Switch the chart display mode to Pie Mode Bar Switch the chart display mode to Bar Mode Line Mode Chart i X 2 Update E 6 u ery Line Pie Bar Size 65 127 MN size 128 255 DOM size 256 511 D size 512 1023 DO Size gt 1024 M Broadcast or MA multicast OW RxRTP I MN Tx Byte M Tx Line Rate paw 15 09 40 15 09 45 15 09 50 15 09 55 15 10 00 15 10 05 w Network Port A0 A1 ME Ri Byte oO Dribble Bit OO alignment Error 15 09 40 15 09 45 150950 150955 151000 151005 O Size 64 vi Vertical Axis Scale Port 40 41 Packet pps Auto User Define teet Minimun Maximun fio DO Vertical Axis Scale Port AQ r Vertical Axis Scale Port A1 Packet pps Auto User Define _ Packet pps Auto User Define Minimun f Maximun ODO Minimun Ig Maximun 1000 Harizontal Axis Scale Start Time 2010 10 02 15 09 37 End Time
73. please input the command counter setusc a0 group 0 enable XTRAMUS TECHNOLOGIES 28 E mail sales xtramus com Website www Xtramus com ATRAMUS C NuTAP S61 HyperTerminal Command mode Command Descriptions mode The mode show command allows you to view Nu TAP S61 s redirect mode aggregation segregation or multi mirror settings The mode set aggregation segregation multimirror mO m1 command allows you to set Nu TAP S61 s redirect mode for Monitor Port MO M1 For example to set NuTAP S61 Monitor Port MO to aggregation redirect mode please input the command mode set aggregation m0 D NUTAP S61 HyperTerminal Command monitor Command Descriptions monitor The monitor show command allows you to view header and media type for all Snow NuTAP S61 s ports Network Port AO A1 and Monitor Port MO M1 The monitor mO m1 portzall header da sa id dip sip dport sport mtu Parameter command allows you to configure NuTAP S61 s Monitor Ports MO M1 The configuration options available includes e DA Destination Address e SIP Source IP Address e SA Source Address e DPORT Destination Port e ID ID e SPORT Source Port e DIP Destination IP Address e MTU Maximum Transmission Unit For example to set Nu TAP S61 Monitor Port MO s destination port to port 9 please input the command monitor m0 header dport 0009 The formats for each available
74. rding Filter Network Port AD RS Filter Network Port Ag J A1 NuSet MiniTAP s Network Port settings include Forwarding Filter Capture Criteria Re direct Filter and Pattern Check Please see the sections down below for detail descriptions XTRAMUS TECHNOLOGIES 55 E mail sales xtramus com Website www Xtramus com ATRAMUS 3 5 1 Forwarding Filter Forwarding Filter Network P Mi Jn AD a Filter w Network Por AN With Forwarding Filter Nu TAP S61 NuTAP 311 will transmit packets from Network Port AO to A1 or the other way around that meet the criteria set in Forwarding Filter will be filtered out or through The Forwarding Filter setting screen contains three tab menus Protocol SDFR Self Discover Filtering Rules and Result A Forwarding Filter Protocol Protocol spFR Result Filter all packets MAC Network Protocol Broadcast ARP Hm Multicast IP4 m UDP Unicast Fy6 PAP VLAN ICMP F ATP M QGinQ Double VLAN Tag IPCS Error CRC Error Pattern Check Description Transmitted packets from Network Port AD to Al for the other way around that meet the criteria set in Forwarding Filter will be filtered out or through Forwarding Filter Network Port 0 W Filter Network Port m A1 Apply Protocol Filter All Packets Click the Filter all packets check box to filter all packets Protocol MAC Br
75. recommended that you should log out if you re not using the HyperTerminal anymore system counter mode monitor Please see the sections down below for detailed information about each command XTRAMUS TECHNOLOGIES 25 E mail sales xtramus com Website www Xtramus com XTRAMUS A NuTAP S61 HyperTerminal Command system Command Descriptions system show The system show allows you to view NuTAP S61 s PCB firmware FPGA versions as well as hardware temperature user The system user show command allows you to view the current users and their passwords The system user admin name password name password command allows you to change the user name and its password of the user with administrator privilege For example if you type in system user admin name test123 and press enter a user named test123 with administrator privilege will be created The system user guest name password name password command allows you to change the user name and its password of the user with guest privilege For example if you type in system user guest name test123 and press enter a user named test123 with guest privilege will be created show admin guest devname The system devname show command allows you to view the device name assigned to NuTAP S61 The system devname set device name command allows you to view the device name assigned to NuTAP S61 show set
76. rms carefully By installing or using this software you are deemed to accept this license agreement Do not install or use this software if you do not accept or adree with these license terms Ed Ido not accept the terms in the license agreement Installshield lt Back Cancel j NuSet MiniTAP 1 0b000 InstallShield Wizard Destination Folder Click Next to install to this Folder or click Change to install to a different Folder Install MuSet MiniTAP v1 0b000 ta Ci Program Filestktramus Change 5 Click the Change button to install the program to another folder or click Next button to install the program into the default destination folder and then continue next step Click Back button to go back to the previous step to modify Installshield E Cancel XTRAMUS TECHNOLOGIES 40 E mail sales xtramus com Website www Xtramus com XTRAMUS NuSet MiniTAP Installation m SuSet MiniTAP v1 0b000 InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation IF vou want to review or change any of your installation settings click Back Click Cancel to exit the wizard 6 NuSet MiniTAP InstallShield Wizard will start installing momentarily Click Install button if the information is correct Installshield 5 NuSet MiniTAP 1 0b000 InstallShield Wizard Installing NuSet MiniTAP 1 0b000 The pragram Feature
77. s you selected are being installed Please wait while the InstallShield Wizard installs MuSet MiniTAP 1 0b000 This may take several minutes Status 7 InstallShield Wizard is installing NuSet MiniTAP Installshield The InstallShield Wizard has successfully installed NuSet MiniTAP wi Db00O Click Finish to exit the wizard 8 NuSet MiniTAP installation completes Click Finish button to exit Gancel Back XTRAMUS TECHNOLOGIES 41 E mail sales xtramus com Website www Xtramus com XTRAMUS To uninstall NuSet MiniTAP you can NuSet MiniTAP Un installation gt Gy Nuset MiniTAP v1 0bO00 b os NuSet MiniTAP v1 0b000 Uninstall NuSet MiniTAP v1 0b000 w A Documents amp Welcome to Xtramus Settings Di sath e Click Start gt Programs gt Xtramus gt Help and Support NuSet MiniTAP gt Uninstall NuSet MiniTAP B x Show updates Sort by Name ae ma Change or Remove Programs z Size 10 47MB 4 Click here For support information Used occasionally Last Used On 2010 9 29 Add New Programs ur computer click Change or Remove Add Remove mounn ia e Go to the Control Panel choose Windows uS yo l eem NuSet MiniTAP from installed program fh gt 7 T Y list and click Remove to uninstall Set Program Access and Defaults E mail sales xtramus com XTRAMUS TECHNOLOGIES 42 Website www Xtramus com
78. se note that under this mode you have to plug Nu TAP S61 s power adapter By connecting Nu TAP S61 s Console Port to PC s Serial Port via RJ45 to Serial cable you can configure view NuTAP S61 s settings with HyperTerminal softwares installed on your PC Please note that under this mode you have to plug NuTAP S61 s power adapter E mail sales xtramus com Website www Xtramus com XTRAMUS 3 NUTAP S61 Management As mentioned in 2 2 Hardware Installation for NuTAP S61 Management you can configure Nu TAP S61 s settings and view statistics generated while performing network tapping with NuTAP S61 by e Connecting NuTAP S61 to PC via an RJ45 to USB cable and accessing NuTAP S61 s settings statistics with NuSet MiniTAP installed on PC e Connecting NuTAP S61 and PC to the same network via an RJ45 cable and accessing Nu TAP S61 s settings statistics with PC s web browser e Connecting NuTAP S61 and PC via an RJ45 to Serial cable and accessing NuTAP S61 s settings statistics with HyperTerminal Please see the sections down below for more information regarding to NUTAP S61 management 3 1 Managing NuTAP S61 with NuSet MiniTAP PC s USB Port Connected via RJ45 to USB Cable NuTAP S61 Console Port PC Running NuSet MiniTAP NuTAP S61 comes with GUI Graphic User Interface utility software NuSet MiniTAP for setting test criteria and system management Please note that you have to connect NuTAP S61 to your PC
79. snmp system The system snmp show command will show the current SNMP Simple Network Management Protocol settings The system snmp writecommunity parameter allows you to set writecommunity the community with write privilege The parameter can be public private or user names The system snmp readcommunity parameter allows you to set readcommunity the community with read privilege The parameter can be public private or user names show save The system save command allows you to save the current settings to Nu TAP S61 s NV RAM Please note that all unsaved settings will be lost after system reboot update The system update firmware FPGA commands allow you to upgrade NuTAP S61 s firmware FPGA The following descriptions are for upgrading NuTAP S61 s firmware However procedures for upgrading Nu TAP S61 s FPGA are quite the same and can be related 1 Type in system update firmware and click enter Press Y to proceed and start upgrading firmware or press N to cancel NulAP S61 gt system update firmware Do you want to update firmware YAN MANWAt A 2 Press Transfer on HyperTerminal s menu bar and choose Send File Transfer Help Send Fil Receive File Capture Text Send Text File Capture ta Printer XTRAMUS TECHNOLOGIES E mail sales xtramus com Website www Xtramus com 26 XTRAMUS Command Descriptions system update Contd
80. st NuTAP S61 s driver is contained in NUTAP S61 s utility software Both Nu TAP S61 s driver and utility software will be installed at the same time Please note that DO NOT connect your NuTAP S61 to the PC via RJ45 to USB cable before the installation For more detailed descriptions about installing NuSet MiniTAP and its functions please refer to NuSet MiniTAP User s Manual on page 35 XTRAMUS TECHNOLOGIES 12 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 2 Managing NuTAP S61 with PC s Web Browser Network PC s Network Interface Card NIC Network Port NuTAP S61 is embedded with a configuration webpage and can be accessed by connecting one of NuTAP S61 Network Port A0 A1 or Monitor Port MO M1 to the network which your PC is connected to as shown in the figure above Before accessing to NuTAP S61 s configuration webpage with your PC s web browser please set NuTAP S61 s IP subnet mask and IPAddress 0 0 0 0 gateway addresses with NuTAP S60 310 Utility according to the Mark Address 255 255 285 256 GatewayAddress O 0 0 network that NUTAP S61 is connected to For more information regarding to set Nu TAP S61 s IP subnet mask gateway addresses please refer to 4 NuTAP S60 310 Utility The figure down below is an example for setting Nu TAP S61 s IP subnet mask and gateway addresses base on network PC settings The settings in the figure down below will be used as configur
81. that meet the criteria set in Capture Criteria will be captured and stored in NuTAP S51 s buffer memory All packets captured and stored this way can be accessed via any Monitor Port upon user requests Capture Criteria Network Port AO Criteria Trigger Buffer Network Port A1 Protocol Capture All Packets Click the Capture All Packets check box to capture all packets Protocol MAC Broadcast Multicast Unicast VLAN QinQ Double VLAN TAG CRC Error Protocol Network ARP IPv4 IPv6 ICMP IPCS Error Pattern Check rotocol Protocol C TP Protocol Button me Apply Apply and save the changes you ve made on this page After making any settings ia on this page you must click the Apply button or all changes will be lost XTRAMUS TECHNOLOGIES 59 E mail sales xtramus com Website www Xtramus com XTRAMUS B Capture Criteria SDFR Protocol SOFR Result IZ Rule Setting pa i D sa 7 sp pe TT DA a SA DA 4 SIP DA amp pip SA amp SIP SA amp DIP 7 SIP amp DIP DA amp SA amp SIP amp DIP r Current Filter 7 Technical Terms DA Destination MAC Address SA Source MAC Address DIF Destination IP Address SIF Source IP Address SDFR Self Discover Filtering Rules is a technology that makes packet capturing filtering over Ethernet easy and convenient SDFR parameters include
82. the SDFR for Capture Criteria from Network Port AO to A1 The criteria available here includes e da a Destination Address A e da a Destination Address A e da b Destination Address B e da b Destination Address B da s Destination Address Single e da s Destination Address Single sa a Source Address A e Sa a Source Address A sa b Source Address B e Sa b Source Address B sa s Source Address Single e Sa s Source Address Single The Parameters should follow the format listed in the table down below e DA SA XX XX XX XX XX XX e DA SA XX XX XX XX XX XX For example to set SDFR for capturing packets with the destination IP address of 192 168 1 1 from Network Port AO to A1 please input the command tapport a0toa1 cap sdfr dip s 192 168 001 100 sdfr Sub Commands The tapport a0toa1 cap sdfr mode da sa dip sip range pair single command allows you to set the SDFR rule settings You can set SDFH for capturing DA SA DIP SIP in range pair or for single one mode The tapport a0toa1 cap sdfr trig mac amp ip ip sa amp dip sa amp sip da amp dip da amp sip mac dip sip sa da command allows you to set the criteria to trigger trig SDFR trig The tapport a0toa1 cap reset command allows you to reset all Capture Criteria settings for packets flow from Network Port AO to A1 type cap Command sdfr reset show The tapport a0toa1 cap show command allows you to
83. tion including captured packets Delta Time us Packet Length with CRC DA Destination Address SA Source Address VLAN Protocol DIP Destination IP Address and SIP Source IP Address Also you can view the content of the captured packets in the bottom field XTRAMUS TECHNOLOGIES 49 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 1 4 Service Service System Upgrade d Terminal Web Connection Function Descriptions Service The System Upgrade function located on the Menu Bar allows you to upgrade NuTAP S61 NuTAP 311 s firmware and FPGA The following section will demonstrate how to upgrade NuTAP S61 NuTAP 311 s firmware with NuSet MiniTAP The processes for upgrading firmware and FPGA are quite the same and can be related 1 Please click Service System Service Languages Help Upgrade Firmware Upgrade on system Upgrade Firmware Upgrade the Menu Bar If you want to upgrade Fen FPGA please choose FPGA Upgrade Terminal Wweb Connection NuSet MiniTAP X File Browse System Information Model NuTAF SB1 Hardware Version vESOO Firmware Version 0 9b008 FPGA Version vi b005 co 2 A NuSet MiniTAP window will pop up Please click the Browse button System Lookin NuTAP S61 RTC v0 9008 A i U pg rad e Fe NuTAP 561 RTC w0 9b008 My Recent P 3 A Load File window will pop up e Please choose the firmware
84. tton right to save apply all the changes you ve made IP The IP section allows you to configure NuTAP S61 NuTAP 311 s IP settings gt DHCP NuTAP S61 NuTAP 311 will acquire IP Subnet Mask Gateway addresses automatically from the network DHCP server gt Static IP Set NuTAP S61 NuTAP 311 s IP Subnet Mask Gateway addresses manually Please input the IP Address Mask Address and Gateway Address according to your network settings in the fields down below Static IP DNS You can set the First Secondary DNS Server Address here in the DNS field TFTP TFTP stands for Trivial File Transfer Protocol If NuTAP S61 NuTAP 311 is connecting to a network with TFTP server please input the TFTP Server IP address here in this field IPAddress U 0 0 O Mark Address 255 255 255 255 Gateway Address 0 0 0 0 ONS First ONS Server Address Standby ONS Server Address TFTF Server Address XTRAMUS TECHNOLOGIES 47 E mail sales xtramus com Website www Xtramus com XTRAMUS 3 1 3 Report Report Counter Report Universal Stream Counter LISC Report Capture Network Port AD Packets Capture Network Port 41 Packets Function Descriptions Report Counter Report The Counter Report button located on the Quick Launch Buttons allows you to view Network Ports and Monitor Ports counter reports and charts on the Main Display Screen You can save the test statist
85. ve the changes you ve made on this page After making any ena settings on this page you must click the Apply button or all changes will be lost XTRAMUS TECHNOLOGIES 64 E mail sales xtramus com Website www Xtramus com ATRAMUS C Re Direct Filter Session Protocol SOFR Session Result Technical Terms DIF Destination IP SIF Source IP Address Apply NuSet MiniTAP supports two Session Filters for each Network Port Each Session Filter allows you to set the packets flow from the SIP Source IP Address to the DIP Destination IP Address The IP addresses that serve as SIP and DIP will be switched Previous SIP Current DIP Previous DIP Current SIP afterward To set the Session Filters please check the check box and input the SIP and DIP ession Button mnm Apply Apply and save the changes you ve made on this page After making any settings wie on this page you must click the Apply button or all changes will be lost E mail sales xtramus com XTRAMUS TECHNOLOGIES 65 Website www Xtramus com ATRAMUS D Re Direct Filter Result Protocol SDFR Session Result Re direct to Monitor Port MO Broadcast TCP UDP DA SA amp VID amp SIP amp DIF SPort amp DPort desseion The Result page will display the settings you ve made in Protocol SDFR and Session pages XTRAMUS TECHNOLOGIES 66 E mail sales xtramus c
86. with an RJ45 to USB cable as shown in the figure above XTRAMUS TECHNOLOGIES 11 E mail sales xtramus com Website www Xtramus com XTRAMUS T NuSet MiniTAP Ioj x File Config Report Service Languages Help H k wo amp a aa a O Reconnect Counter LIS Cap 40 Cap 41 Network Port 40 Network Port Al Monitor Port MO Monitor Port Mi System Nu TAP S61 El Y NuTAP S61 g System Information be SM KS8610000001 EE Maetwark Part AD Status go Connection Mode Auto All g o Link Status AQ Link Link Down 0 Speed NIA moun 5 Flow Contral Off i LA Rate Control Off EA Maetwark Part amp 1 Status go Connection Mode Auto All 2 EO Link Status Link Link Down l LAB Speed VIE qo ud A a ie a O b udin W LS 5 Lo VETT Aes OO Rate Control Of Network TAP with Multi Redirect and Smart Filtering Rule Fl eg Monitor Port MO Status j A O Connection kode Auto All 2 Ea Link Status Link Link Down O Speed NIA f Flow Control Off EL Monitor Part WIT Status HO Connection Mode Auto All a 8 Link Status Link Link Down O Speed NIA f Flow Control Off Ei Connected A When NuTAP S61 is connected with PC via its RJ45 to USB cable you can set test criteria save view testing logs and upgrade NuTAP S61 s firmware FPGA with NuSet MiniTAP However before using NuSet MiniTAP s features and functions you have to install it on your PC fir