1. expect a stable and rectified echo pulse from the receivers To achieve this STEIM has developed a small circuit board which generates the proper echo pulse This board has to be powered with two powersupplies Teala CON9 9V and 5V see next paragraph CON12 9V and 5V see next paragraph CON14 Channel 1 Rx and GND CON11 Channel 2 Rx and GND CON9 and CON12 are equal they don t belong to a specific ultrasound channel You should connect an ultrasound receiver as following RECEIVER on receiverboard a 9V GND Rx 5V For the receiver boards please contact STEIM Check the website for more details www steim nl 2 3 3 the external power supply The external power for the ultrasound can be hooked up using CON15 Without this external power the ultrasound will not work The external power must be minimum 9V DC and maximum 12V DC DO NOT CONNECT THE JUNXION BOX TO AC POWER i y r3 f ra P rati wet J D O 7 J g on OOo O oT j aun o p g ma g g hale a 2 n LILLJ g U le e 2 y R le OD 5 6 Le Rea i j t D r steim design RWA 2005 CON15 External power 9V 12V DC a 9V battery block will do fine The external power input is protected against reverse connecting 2 4 Visual Feedback The device has 3 LEDs mounted on the board LED1 green blinks when data is transmitted to hostmachine LED2 red USB power present LED3 red External power present Notes on
2. potentiometers think of the volume knob on your audio amplifier The potentiometer has 3 leads which you connect to GND Analog input and SV When you reverse GND and 5V the turning direction reverses as well If you want to hook up a potentiometer to your junXion box you simply do the following See section 4 for more sensors re 3 3 Example of ultrasound connected 3 3 1 Connecting the trasnsmitter The ultrasound works with a transmitter and a receiver The receiver must be mounted on a STEIM ultrasound receiverboard See next pictures to see how to connect these sensors The transmitter part 1s easy to connect take ouput Tx and GND See next picture Connection of ultrasound transmitters 3 3 2 Connecting the receiver board For the receiver board you need to connect four wires The Rx and GND together with the powersupply 5V and 9V See next picture ora WA oV te wee Ve GND shai amp Ba oat en 2 i y A oO 5 Connection of ultrasound receiver board 3 3 3 Connecting the external power supply The external power like a battery can be easily connected See next picture Connecting the external power 3 4 Connecting the junXion box to the computer When using switches and analog sensors no ultrasound 1 Hook up your sensors and buttons to the junXion box 2 Turn on your computer and start up the junXion program 3 Connect the junXion box to the c
3. the green LED When the green LED is on instead of blinking it means that the junXion box is transmitting data continuesly This can happen when one or more analog input is floating This will not harm the device If you want to avoid this be sure that all analog inputs have a stable input You can do this by connecting the not used analog inputs to ground GND When you re using a noisy or sensitive sensor like an accelerometer it is unavoidable to have a continues dataflow Notes on the USB power LED When this USB powerLED is off while the USB is connected to the junxion box you should disconnect the junXionbox from the USB cable and search for a possible shortcircuit in your sensor wiring Notes on the External power LED When the External power LED is off while the external power is connected and turned on you should immediately disconnect the yunXion box from the external powersource The error will be found in wrong connections with the ultrasound 3 0 Using the junXion box Now that you know where to connect your switches sensors and ultrasound sensors it is time to hook up your sensors and switches connect it to the computer launch the junXion program Macintosh computers only and play 3 1 Example of connected switch SWITCH 1 3 2 Example of analog sensor connected A lot of sensors you can use are so called passive sensors This generally means they behave like variable resistors called
4. ER exceed the range 0 5 V When the junXion box runs on USB power the maximum amount of power available is 375mW This means that the 8 analog channels can deliver a total of 75mA to the sensors The result is that the average maximum current consumption per sensor is 9 3mA The powerline SV USB power should never be shorted to ground Don t solder on the board while it is connected to the USB When using an external power supply be sure to first connect the junXion box to the computer and then turn on connect the external power supply When powering off first disconnect the external power then disconnect from the computer The junXion box is HID compliant so you can connect it when your computer is already on 2 1 Switch Connections You can connect up to 16 switches to the junXion box The switch inputs are on the strips labelled CON6 CON7 en CON8 and are meant to switch to ground GND O junxXion a or sao Ly Oo Oa 66 pa fi O O oS p gt d gt R gogpooooooooopooonooo Y o og ave 3 o a5 ur pA pong ooog fo 4 2 nood b oo CONGO Inputs 1 4 CONS Inputs 5 12 CON7 Inputs 13 16 CON3 GROUND You should connect the switch as following switch switch input con6 con7 or cons GND con3 22 Analog Sensor Connections You can connect up to 8 analog sensors to the yunXion box The sensor inputs are on the strips labeled CON4 and CONS and have to be referenced to 5V
5. JUNXION BOX USER MANUAL Introduction The STEIM junXion box allows you to connect up to 8 analog sensors 16 switches and 2 channels of ultrasound to your computer via USB The jun Xion box is a bare printed circuitboard with all necessary electronics on it It s up to you to solder your sensors and switches on the board This means it is necessary to have some soldering experience as mistakes in soldering can cause the junXion box not to function correctly and might even break it beyond repair It is possible to use multiple junXion boxes at once with the junXion v2 software and a USB hub Aside from soldering experience it can be very helpful to have some electronics knowledge This manual provides the basic information you need to connect your sensors and switches to the junXion box For additional information on specific sensors or customized schematics for certain sensors STEIM refers to the internet Specifications The STEIM junXion box is a HumanInterfaceDevice HID compliant The STEIM junXion box is a lowspeed USB device USB1 1 1Mb s The junXion box connects to a host computer via a standard USB typeA typeB connector A D conversion amp bit Ultrasound distance measuring 12bit Contents 1 1 1 1 2 2 1 2 2 2 3 2 4 3 1 3 2 3 3 3 4 general information and warnings general safety warnings specific issues PCB connection layout switch connections analog sensors connections u
6. and GND steim CON4 Inputs 1 4 CONS Inputs 5 8 CON2 5 volt CON3 GND Notel Be aware of the fact that you can draw a maximum of 75mA for your sensors Note2 When you are not using all the analog inputs and you leave the inputs open you create so called floating inputs This will cause the junXion box to send out junk data for these inputs You can avoid this by connecting the loose inputs to GND Typical sensor application can be found in Chapter 4 You should connect an analog sensor as following 5V con2 Sensor Signal to Analog Input con4 con5 GND con3 2 3 Ultrasound Connections You can connect up to 2 ultrasound transmitters receivers to the yunXion box You need an external power supply to make the ultrasound work This will be explained in the next paragraph 2 3 1 the transmitter part The transmitter outputs are CON10 and CON13 7 on j gggoogggg rA JA og 2S 8 8 Q Dip N T1 1 1 T 1 ai T T T T T T yio g 0000 po re o So lelelelelelelelelajelelelelelelelel O P We g boogo peo agannannonggoannnnnn o O OS 3 nooo OOOO A i o a oo o bood po 900000 ool O w T al a Ss pogopbce steim design RWA 2085 O CON13 Channel 1 Tx GND CON10 Channel 2 Tx GND You should connect an ultrasound transmitter as following TRANSMITTER L gt GND 2 3 2 the receiver part The receiver inputs are CON14 and CON11 These inputs
7. ltrasound connections 2 3 1 The transmitter part 2 3 2 The receiver part 2 3 3 The external power supply visual feedback Using the junXion box Example of connected switch Example of connected analog sensor Example of connected ultrasound 3 3 1 Connecting the transmitter 3 3 2 Connecting the receiver board 3 3 3 Connecting the external power supply Connecting the junXion box to the computer 1 2 GENERAL SAFETY WARNINGS Read this manual carefully before using the junXion box The junXion box onboard power is derived from the USB bus The power is fused so you don t have to worry you will blow your USB bus on your computer However you have to watch out that you do not short the USB bus on the connector itself The device does not contain user serviceable parts All service work should be done by STEIM unless STEIM explicitly tells you to do it yourself Besides these precautions you should also take the usual precautions as with all electronic music equipment like avoid to much heat don t spill any fluids into it don t use it underwater don t put house voltage on the connectors etc Don t solder on the board while it 1s connected to the USB port 1 3 SPECIFIC SAFETY ISSUES STEIM should be contacted immediatly if any problem or malfunctioning takes place The junXion box can be damaged by making wrong connections between the board and the sensors The voltage on the analog inputs signal in should NEV
8. omputer using a USB cable 4 In the junXion program go to file and choose rebuild device list When you want to quit playing or solder some more sensors switches to the junXionbox you simply unplug the USB cable from the junXion box Now you can solder your new sensors switches to the junXion box When you re ready for the next try just plug in the USB cable again and rebuild the device list in the junXion program Using external power for the ultrasound 1 Hook up your sensors including the ultrasound and switches 2 Turn on your computer and start up the junXion program 3 Connect the junXion box to the computer using a USB cable 4 Connect and turn on the external power to the junXion box 5 In the junXion program go to file and choose rebuild device list When you want to quit playing or solder some more sensors switches on the junXion box you first disconnect the external power and then disconnect the USB cable from the jun Xion box The junXion box is now ready for you to solder on it The reason why the USB cable and the external power should be removed in the specified order is to save battery power If the USB cable is not connected while the external power is turned on the junXion box will draw much more current from the external power This is an important issue when using batteries
Download Pdf Manuals
Related Search
Related Contents
013 KESO AccessPoint SNC-RX550N SNC SUFORT MANUAL DE INSTRUÇÕES PARA MONTAGEM E 1 - Support Tents for In-water Displays - Miami International Boat Show Imitation Security Camera eS-650 eS-650s Easyrock Italian MINISTÈRE DE [ÉCOLOGIE ou DÉVELOPPEMENT Foscan, INN-temoporfin Copyright © All rights reserved.