Home
AM100 Auto Mixer Manual - Great Lakes Orthodontics
Contents
1. Mixing Cup Use the Spatula to remove the alginate material e Alginate material will set Bubble Free 9 Setting the Mixer Timer The Timer has 5 pre programmed settings Memory Mixing Time seconds 6 Po 2 8 3 10 4 12 5 15 Press the MEMORY SELECTION BUTTON to select one of the pre programmed time settings required for mixing The corresponding indicator light will be lit e The and Time Adjustment Keys can be used to increase and decrease the time setting for pre set position No 5 The setting range 5 4 16 seconds Note the Time Adjustment Keys will only change pre set position No 5 e To change the No 5 Timer pre sets Choose the No 5 pre set position using the MEMORY SELECTION BUTTON the corresponding indicator light will turn on Press the MEMORY SELECTION BUTTON and hold for 5 seconds it will beep once Once it beeps release the MEMORY SELECTION BUTTON Press the and TIME ADJUSTMENT KEYS to increase and decrease the time setting for that pre set position Press the MEMORY SELECTION BUTTON to lock in this new setting e Should you wish to change this setting again or return to the original pre set position just repeat the above process A grid of mixing times time settings Water temperature between 50 68 F 10 20 C are listed below Alginate Scoops Mixing Time seconds Impressions Made Small Full Arch Medium Full Arch Large Full
2. AM100 Centrifugal Auto Mixer User Manual 10 11 12 Table of Contents User Notice Warranty Liability Information Indications for Use Product Introduction 4 1 Parts and Accessories 4 2 Product Specifications Installation and Use 5 1 Conditions for Installation and Use 5 2 Installation Transportation Power Mixing of Alginate Powder Setting the Mixer Timer Maintenance 10 1 Mixing Cup 10 2 Cleaning the Mixer Troubleshooting Product and Accessories 9 10 11 1 User Notice Thank you for ordering the AM100 Centrifugal Auto Mixer Prior to using this product please read this User Manual carefully for set up usage and maintenance instructions Please keep this User Manual handy as a reference for your AM100 Centrifugal Auto Mixer Please use this machine according to the instructions described in this User Manual Failure to do so may result in operator injury or machine malfunction If the purchaser does not file a written complaint to Great Lakes Orthodontics within seven 7 days of receiving the product we will assume the purchaser has completely understood the contents of this User Manual and accepted the product as shipped Please contact Great Lakes Orthodontics 1f you have any problem with the machine The manufacturer reserves the right to make changes and improvements to any of the products described in this manual without prior notice 2 Warranty Liability Information The A
3. Arch 10 Maintenance 10 1 Mixing Cup e After setting the remaining alginate material inside the mixing cup can easily be removed Once removed use a clean soft cloth to wipe it down e The small hole at the center of the cap Fig 5 should be cleaned to ensure that it is not clogged or blocked in any way Important Information The small hole at the center of the cap must remain clear If it becomes clogged or blocked then the mixing cup cap will be difficult to open or close Any water remaining after cleaning must be removed completely otherwise it will cause a mixing error e The Mixing Cup is a consumable component Once it becomes distorted or cannot be sealed tightly please replace with a new one 10 2 Cleaning the Mixer e Use a cloth to clean any dirt on the outside of the Mixer Use a neutral cleaning agent to remove large amounts of debris NOTE DO NOT CLEAN THE INSIDE OF THE MIXER OR THE MIXER WELL WITH WATER Important Information Never use solvent or volatile chemicals for cleaning This may damage the machine components and will cause the machine surface to fade 11 Troubleshooting If you experience a malfunction please try to resolve the problem by using the Troubleshooting Chart page 9 Ifthe machine 1s still malfunctioning please contact Great Lakes Orthodontics for further instruction and assistance Problem Mixer does not power on turn on when you press the power button The dig
4. M100 Centrifugal Auto Mixer is warranted for one 1 year from date of purchase Great Lakes Orthodontics shall not assume any responsibility for any malfunction damage or accident of personal bodily injury due to the improper removal modifi cation maintenance or repair of the AM100 Auto Mixer by parties other than us Great Lakes Orthodontics shall not assume any responsibility for any malfunction damage or accident of personal bodily injury due to using a product not provided by us Great Lakes Orthodontics shall not assume any responsibility for any malfunction damage or accident of personal bodily injury due to the improper removal modifi cation maintenance or repair of the AM100 Auto Mixer that did not include parts provided by us Great Lakes Orthodontics shall not assume any responsibility for any malfunction damage or accident of personal bodily injury due to the improper operation of the AM100 Auto Mixer not in compliance with this User Manual Great Lakes Orthodontics shall not assume any responsibility for any malfunction damage or accident of personal bodily injury caused due to the usage environment not being in compliance with the power installation environment and conditions specified in this User Manual 3 Indications for Use Use of this product is restricted to medical dental professional use only e This product is suitable for mixing 25 100g of alginate powder in a short time period This pro
5. duct should not be used to mix caustic material 4 Product Introduction 4 1 Parts and Accessories Machine body Cover Start Stop button Time memory selection button Time adjustment buttons Time display Time memory number position indicator Indicator light Power cable receptacle 10 Main power switch 11 Power cable ps Stir stick I Spatula 14 Water dosing bottle 15 Mixing cups 4 ea 16 Fixed bolts for transportation 4 2 Product Specification Power Supply 110v 60Hz Power 400W Revolution 3 600 rpm 60Hz Timer 4 16 sec adjustable by second Memory 5 initial settings 6 8 10 12 15 sec Net Weight 19kgs 41 9 105 External dimension 215mm w x 310mm h x 275mm d 5 Installation and Use 5 1 Conditions for Installation and Use For indoor use only e Please use at temperatures between 41 104 F 5 40 C e Please use at a relative humidity of lt 85 e Please use the power voltage of 110v 60Hz e Please use at an electric current of 10A 5 2 Installation Important Please remove the two 2 fastening bolts fixed at the bottom of the machine Fig 1 before using this product or the machine will be damaged The machine should then be installed on a stable counter or table with a flat surface e Never install near flammable or explosive substances e Should the machine malfunction do not attempt to use Using the machine in this cond
6. ital display does not come on The initial running is slow Abnormal noise or vibration while running Motor does not start or alginate mixing is uneven Troubleshooting Chart Cause Bad power cord connection Main power switch is in OFF position rear of Mixer Burned out fuse Defect in PC board Indicator light 1s bad Defect in driving motor or belt Defect in the starting condenser Too much alginate in mixing cup Mixer started but there is nothing inside the mixing cup Damaged belt Alginate powder splashes caused by loosening of mixing cup cap Incorrect amounts of alginate and water Driving motor triangular belt or round belt 15 damaged The sensor lock in the machine cover is malfunctioning Method Inspect power cord connection Turn main power switch on Inspect fuse and change if needed If the fuse is burned out contact Great Lakes Orthodontics for repair instructions Contact Great Lakes Orthodontics for repair instructions Replace the indicator light Contact Great Lakes Orthodontics for repair instructions Contact Great Lakes Orthodontics for repair instructions Try smaller amount of alginate Place properly filled mixing cup in the unit and retry Contact Great Lakes Orthodontics for repair instructions Check to see if the mixing cup on the cap 1s tightly closed Refer to alginate suppliers mixing ratios Contact Great Lakes Orthodontics for repair instructi
7. ition may result in additional damage to the mixer as well as voiding the warranty Transportation Important If the mixer is to be returned for repairs or brought to another location please fasten the aforementioned fastening bolts to avoid malfunc tion or damage e Not securing the motor with the two fastening bolts when transporting shipping voids the product warranty Please store the two fastening bolts for future use 7 Power e Connect the Power Cable to the Power Cable Receptacle on the rear of the machine Fig 2 Plug 3 prong grounded end of Cable into the power source wall receptacle e Turn mixer on at Main Power Switch located on the rear of the machine Fig 3 When the switch is turned on the Memory Indicator Light and Time Display on the Operation Panel should be lit Fig 1 l Fig 3 Fig 2 8 Mixing of Alginate Powder Prepare the alginate powder and cool water 50 68 F 10 20 C in the Mixing Cup as described in the next step Important Information The hardening times of the alginate can be controlled by water temperature If cool water is not used the hardening time will be shortened Measurement of the alginate powder should be done according to the alginate manufacturer s instructions Add the corresponding amount of water to the alginate powder already in the Mixing Cup The dosage to be mixed should be between 25 100g In order to prevent malfunction of the machine do no
8. ons Check to see if the machine cover is closed tightly 12 Product and Accessories Part Number Description Quantity 100 060 Full Machine 100 061 Power Cable 100 062 Mixing Cup 100 063 Water Dosing Bottle 100 064 Spatula 100 065 Stir Stick Great Lakes Orthodontics Contact Information Telephone 800 828 7626 Toll free U S amp Canada 716 871 1161 Worldwide Fax 716 871 0550 Email info greatlakesortho com Website www greatlakesortho com Great Lakes Orthodontics Ltd 200 Cooper Avenue Tonawanda New York 14150 4 Ta gt D a SMPI165Rev 110509 S 330
9. t exceed 100g Cap the Mixing Cup by covering the cup then pressing down on it while turning it to lock it in place Important Information The Mixing Cup must be completely tightened or the alginate powder will splash during mixing and cause the machine to malfunction The Mixing Cup and Mixing Cup Cap are considered accessory products and not included in the machine war ranty If the cap cannot be secured tightly please use a new mixing cup and cap Place the Mixing Cup inside the mixing well Fig 4 Fig 4 Close the Mixer Cover The Mixer will not start if the cover is not secured properly Do not Start Run the machine when the Mixing Cup 15 empty Based upon the amount of alginate powder added to the mixing bowl set the timer Please refer to Setting the Mixer Timer section 9 Once the timer is set press the Start Button The digital display will count second by second and will display the time of completion Do not force open the cover while the machine is running as this may cause injury to the operator or damage the machine Important Information Should you need to stop the Mixer during mixing press the Stop Button and the Mixer will immediately stop During mixing should the Mixer detect any abnormal condition it will stop automatically e The Mixer will beep to indicate that it has completed the mixing cycle e After making sure that the Mixer has stopped open the cover and remove the