1. Advice regarding thermostats and regulators Electrical floor heating gives a very comfortable and economical heat Floor heating is somewhat slower to regulate than wall mounted heating and the best results are achieved when using an electronic thermostat for temperature control In wet rooms it is common to use a thermostat with a floor sensor only Comfortable bare foot temperature is usually around 26 C 79 F User manual The heating cable system should not be turned on before the floor has hardened naturally The thermostat or control system must be used according to the manufacturer s instructions Avoid drilling cutting attaching bolts or similar in the heated floor If this must be done contact an electrician who can help locate heating cables Documentation of the heating system received from the installer should provide information on where the cables are located In rooms with an area power of 100 W m or more for example in a bathroom carpets are not to be used Caution is to be taken when placing insulating items on the floor such as diaper packages heaps of clothes and so on Such items should preferably be placed in other areas In rooms with an area power of 100W m or less pay attention when placing insulating items on the floor for example carpets or furniture without feet Permanent installations covering a room area should always be installed in non heated areas The heating cable is tested in conformity with IEC 60800
2. EN50265 IEC 60332 1 The table below shows recommended BLUE THERMAL heating cables 17W m and centre spacing for various room sizes and outputs Room Load cc cm Load cc cm Load cc cm Load cc cm m 60 80 W m 80 100 W m 100 120 W m 120 150 W m E EA 3 6 1x446202 25 1x446203 20 1x446205 14 1x446200 12 8 1x446208 27 1x446205 19 1x446200 16 1x446207 13 9 1x446200 25 1x446206 18 1x446207 15 1x446208 12 Vent Axia VAUFHC WARRANTY FORM Installed by Company Installation address Room area m Rated values Cable type s W Single Twin conductor Linear output Rated resistance Rated voltage Check measurements Before installation Before pouring Before connecting Date amp signature Element resistance 5 10 Insulation resistance 100 MOhm Construction details Installation depth cm No of elements mats installed stk st kpl pieces Installed heated area m Area output in heated area W m Size circuit breaker Trip level RCD GFCI ground fault protection Earthed cable screen Earthed chicken wire Other specify Max temperature in construction is limited to 80 C by Planning Installation Limiting protecting equipment specify Control system Designation of type Floor sensor Room sensor Other specify Installer statement The heating cable product is installed according to Vent Axia installat
3. or pressed down into it This can be prevented e g by installing the cable on chicken wire It is often a good choice to start with placing the splice s in the floor near the thermostat The splice s must not be placed in a tube or in a wall The end seal of a twin conductor cable is preferably placed in a dry zone of the floor Apply glue attach bands or fix cable ties to keep the heating cable in place at the correct C C distance It is important that the cable will stay in place when the floor is poured Keep the correct distance C C between cables and avoid at all times overlapping or crossing of cables as this causes unwanted thermal effects If attaching the heating cable to reinforcement bars longitudinal bars are preferred The heating cable shall not be attached to pipes in the floor or other components preventing heat flow Be aware that the cable will be exposed during installation to mechanical damage when placed on reinforcement bars Heating cables should not be installed beneath kitchen cupboards walls or other permanent installations which do not allow air circulation Furniture that stands on the heated area must have feet to ensure that air can circulate and that heat emission from the floor is possible The heating cable is never to be cut or shortened in any way If a floor sensor is connected to the thermostat this should be installed inside a tube exactly between two cable strings in the floor The end of the tube shoul
4. 88 UK NATIONAL CALL CENTRE Newton Road Crawley West Sussex RH10 9JA SALES ENQUIRIES Tel 0844 8560590 Fax 01293 565169 TECHNICAL SUPPORT Tel 0844 8560594 Fax 01293 539209 For details of the warranty and returns procedure please refer to www vent axia com or write to Vent Axia Ltd Fleming Way Crawley RH10 9YX 446258A 0111
5. VAUFHC Underfloor Heating Cable Range Installation and Wiring Instructions Stock Ref N 446201 446202 446203 446204 446205 446206 446207 446208 446209 446210 446211 446212 446213 Venf Axia PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Installation Instructions for BLUE THERMAL heating cables Product description BLUE THERMAL resistive twin conductor heating cable with a metallic alloy as the warm conductor and a solid copper wire as the return conductor The heating cable has a factory fitted end seal and an integrated hidden splice marked SPLICE on the cable between the cold lead and the heating element itself Constant power As stated on cable package Watt Rated Voltage 230V Maximum Voltage 500V Conductor insulation XLPE PEX Outer sheath PVC Minimum bending radius 5x outer diameter of cable Application The main area of use for BLUE THERMAL cables is underfloor heating Cable output W and output per meter W m are determined with regards to room size and type type of installation and floor type BLUE THERMAL cables can be used both in new and renovation projects Important Before the installation starts Read through these installation instructions before any work starts This product should only be installed by qualified personnel who are familiar with the construction and operation of the product and risks involved The installation
6. d be sealed with tape When installing the sensor in a tube it can be changed later if needed Make a drawing of the installation and or take a photograph for future reference before pouring the floor 2 Avoid stepping or dropping items on the cable and use caution in further works with pouring the floor 3 Measure insulation resistance and element resistance after the cable has been installed but before any concrete screed mortar is poured To build a good and efficient heated floor the slab on the sub floor containing the heating cables must have good heat conductivity to create an even temperature throughout the slab securing efficient heat emission from the cable to the room 4 When embedding heating cables in concrete screed mortar this must be mixed correctly as prescribed by the vendor Mix the materials well before pouring the concrete screed mortar onto the subfloor and the cables 5 BLUE THERMAL cables must be embedded with minimum 5 mm 0 2 inches concrete screed mortar above the cable when the top floor covering is tile or stone The minimum is 10 mm when the top floor covering is vinyl linoleum carpet engineered wood or other 6 Compact well to prevent air pockets and a porous slab The concrete screed mortar must surround the cable entirely to ensure good and necessary heat conductivity from the cable to it s surroundings Good heat conductivity is important for the function of the floor but also to prev
7. ent excessive temperatures Some concrete types can be mixed with small amounts of water as specified by the vendor In these cases pay special attention to the mixing and the compacting as these floors easily becomes porous and thereby thermally insulating It is recommended to use concrete screed mortar designed for heated floors Thermally insulating types cannot be used T The heating cable is not to be used before the concrete screed mortar has naturally hardened and dried This can take up to 6 8 weeks Please consult the instructions guide provided by the vendor of the concrete screed mortar 8 A thermostat is recommended to regulate the heating cables Before this is connected measure the insulation resistance and the element resistance of the heating cable to check cable integrity This will also reveal any damage done to the cable during installation The documentation supplied with the thermostat is to be passed to the owner of the installation being a part of the total documentation of the heating cable system The heating cable must be connected to electrical earth properly and always be protected by a ground fault circuit breaker This breaker should have a maximum trip value of 30 mA If installing more than one heating cable in a room both cables can be connected to the thermostat However ensure the cables are connected in parallel not series and that the total power output does not exceed the limit of the thermostat
8. ion instructions and the building owner has been informed about precautions and limitations which apply to heated floors Date signature stamp Special notes about this installation Building owner Purchaser Warranty form and user manual has been received read and understood Date amp Signature Product extended warranty All of our heating cable units and their components are thoroughly tested during production The final test is a high voltage test and measurement of the conductor resistance Only the units which have passed the tests are sent to the market Vent Axia offers an extended 10 year warranty on defects in material and workmanship in the sold product under proper and normal use and service In case of a defect Vent Axia will repair or replace the product Please see the terms of warranty for further details The warranty does not extend to defects caused by a faulty installation For the extended warranty to be valid these installation instructions must be accompanied with The written warranty form inside each box containing a product must be filled in This is to ensure a correct installation and that no damage has been done to the product during the installation If during the installation a heating cable is damaged it will have to be replaced before the construction is finished Vent Axia must be given notice of any defect within 30 days after the defect was discovered and the warranty form correctly filled in mus
9. of this heating product shall be in accordance with the manufacturer s instructions and the regulations of the authority having jurisdiction Measure insulation resistance and heating element resistance before the cable is taken out of the package The heating cable should never be installed directly in contact with combustible materials except where the following condtions are met e The heating cable has an outputper meter of 10W m 3W ft or less e Heated area is 80W m 7 5W ft or less To prevent high temperatures in the floor construction the following must be followed e Max 80W m 7 5W ft max 10W m 3W ft in wooden floors e Max 80W m 7 5W ft when the top surface is parquet laminate or carpet e Max 150W m 13 9W ft when the top coveringis stone tiles vinyl or linoleum When installing heating cables beneath a wooden floor it is recommended to contact the vendor of the floor to ensure the floor is suitable for the planned heating system including output in W m W ft Some wooden floors allow a maximum area power as low as 60W m 5 6W ft and restriction on maximum surface temperature as low as 27 C 81 F installation instructions step by step 1 Plan the installation first and then lay the cable in the pre calculated C C distance on the sub floor It is recommended that the sub floor is insulated to reduce heat loss downwards However the heating cable must not be in contact with the insulation
10. t accompany the claim in order for the extended warranty to be valid The VenF Axia Guarantee Applicable only to products installed and used in the United Kingdom For details of guarantee outside the United Kingdom contact your local supplier Vent Axia guarantees its products for two years from date of purchase against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product e Has been installed and used in accordance with the instructions given with each unit e Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit e Has not been subjected to misuse neglect or damage e Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase The guarantee is offered to you as an extra benefit and does not effect your legal rights Axi VenF Axia Head Office Fleming Way Crawley West Sussex RH10 9YX Tel 01293 526062 Fax 01293 5511

Download Pdf Manuals

image

Related Search

Related Contents

CLUB3D Radeon HD 5450 Noiseless Edition AMD Radeon HD5450 1GB  Q-See H264 DVR User Manual  Campus Recreation Services Maryland Sport Clubs GoPro Video  Monarch Plus RC3/R  Churrasqueiras Rotativas  Samsung NP-Q1B User Manual  PI Manufacturing Internet Phone User's Manual  Samsung SPF-105P  取扱説明書一覧  User Manual - Totalcomp Scales & Components  