1. electriQ Pro Range Antibacterial Digital Dehumidifier with Humidistat and Large Tank PD3OE 30 litres per day PD45E 45 litres per day USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using our innovative Dehumidifiers and keep it safe for future reference Visit our page www electriQ co uk for our entire range of Intelligent Electricals Contents Safety Instructions Features Installation Parts and Control Panel Operation reference guide ae eeeceseseceeccesesnseeeeees Positioning Water Drainage hae secceccecceeseeeesssessessesesssesees Care and Maintenance Troubleshooting Technical Data 10 11 12 13 15 SAFETY INSTRUCTIONS Important e Carefully read the instructions before operating the unit If used on commercial premises the site manager should ensure that the operator has access to the user manual and understands the operation of the unit e This appliance is for indoor use only and intended for use in a commercial or domestic environment only Any other use is not recommended by the manufacturer and may cause fire electrical shocks or other injury to operator or property e Rating This unit must be only connected to a 220 240 V 50 Hz earthed outlet e Installation must be in accordance with regulations of the country where the unit is used e f you are in any doubt about the suitability of your electrical supply have it checked and if necessary mo
2. Asked Questions Why doesn t the dehumidifier seem to extract much water if the temperature is low This is a compressor dehumidifier which works best in temperatures above 15 C If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water If you want to use a dehumidifier for outside buildings unheated properties boats or garages please check our desiccant range Why doesn t the unit work or stops suddenly The water tank may be full or displaced To rectify empty the tank and carefully place the tank back in the unit Also the unit may be running in dehumidifying mode with a low room temperature Please check if the room temperature is lower than 5 C If so the unit will stop working while in dehumidifying mode unit may be defrosting The ambient operating range is between 5 C and 32 C with a relative humidity ranging from 40 to 80 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and or hot air comes out from the air outlet grill why When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity During the cold cycle there should be cold air coming out of the unit During the hot cycle hot dry air should be coming out of the outlet grill Troubleshooting Hot or cold air Normal Operation When the unit is in dehumidifying being produced mode it absorbs humid air from room and freezes it to redu
3. cause the unit not to operate Do not remove the float from the water tank The water full sensor will no longer be able to detect the water level correctly without the float and water may leak from the water tank 2 Continuous draining Water can be automatically plumbed in or drained into sink a larger recipient or through the wall into an outside drain by attaching a pipe to the unit 12 mm internal diameter not included Insert the pipe into the drain outlet at the back of the unit as shown in here Make sure the connection between pipe and the drain outlet is tight and does not leak Then direct the pipe to a suitable drainage point This unit uses gravity fall to dispose water hence the drain 11 should be lower than the unit water outlet Put the tank back Be sure to run the water pipe downward and let the water to flow out smoothly Do not kink or bend the pipe NOTE When the continuous drain feature is not being used remove the drain hose from the outlet The permanent drain can be used in conjunction with water pump e g when draining a cellar to lift the water upwards In cold conditions please ensure that pipe is not freezing up Care and Maintenance Always shut off the unit and unplug from the mains before cleaning or performing any maintenance When it is not in use for long periods it is advisable to remove the plug from the power socket Do not use chemical
4. solvents such as benzene alcohol or gasoline as they may cause irreversible damage to the unit Clean the Grille and Case and Maintain the filters Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock and can lead to the insulation to deteriorate or cause the unit to rust The air intake and grilles get soiled easily so use a vacuum attachment or soft brush to clean If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit washable filter Clean the carbon and the mesh filter with a vacuum cleaner or soft brush Replace the filter in position as shown in the diagram above a Note Never use the unit without the antibacterial mesh dust filter The active carbon filter is optional and should be replaced if necessary after 1 1 years of usage 12 Clean the water tank Every few weeks clean the tank to prevent growth of mould mildew and bacteria Partially fill the tank with clean water and add a little mild detergent Swish it around in than empty the tank and rinse NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation Frequently
5. castors They are intelligent dehumidifiers which will extract unwanted humidity while saving money due to their humidistat and power saving logic Electr1Q Pro range of dehumidifiers features adjustable humidistat in increments of 10 from 40 70 RH insuring your space is not dried too much and power is not wasted PARTS 1 Control panel 4 Air Inlet and Filters 7 Permanent drainage OU OD 2 Dry Air Outlet 3 Front case 5 Recessed Handle 6 Rear case 8 Water tank 9 Castors 10 Power cord and plug varies according to region Filters 1 Washable mesh filter washable filter active carbon filter 2 Activated carbon filter Optional filter fixer CONTROL PANEL amp HUM WSPEED CNT 40 50 60 70 HO on rtmer hl LO 6 7 8 9 10 1 1 SHUM humidity control keys 40 70 RH and continuous mode CNT 2 4 aller fan Speed settings Key High Low 3 g D Humidity and Temperature display 4 TEMP Temperature display key 5 Power ON OFF key 6 Humidity selection lights 40 50 60 70 and CNT continuous mode 7 HI Turbo fan speed indicator light 8 LO Quiet fan speed indicator light 9 Orme Timer selection key 0 24 hrs 10 Tank Full light Vo red if tank full or not properly in pla
6. ce 11 Power on led light Humidity Level amp Timer 2 digit display The two digits led indicator performs the following functions 1 When the unit is plugged in it will indicate the room humidity level 2 When the humidity level is selected it will indicate the set humidity than will revert to room humidity display after few seconds 3 When the stop timer is programmed will show the set timer than revert back to humidity display 4 When Temp key 4 is pressed will show the room temperature than will revert back to room humidity display after 12 seconds Notes When humidity level is outside the normal operational parameters will show LO HI If ambient humidity is lower than 35 it will show LO If ambient humidity is higher than 95 it will show HI 1 Operation Reference Guide Power Key 5 Press to turn the dehumidifier ON or OFF Humidity Settings Key 1 can set the target humidity level within a range of 40 RH Relative Humidity to 70 RH in 10 increments Respective target humidity indicator light 6 will be lighten Compressor will work until desired humidity is measured than will stop unit working economical fan mode only The fan will move the air around the room ensuring the entire air in the room is processed and humidity correctly measured Ideal domestic office environment settings are 50 60 For drier air laundry mode press the key and set to a lower percent value e g CNT or 40 For allo
7. ce the humidity During the cold cycle there should be cold air coming out of the unit During the defrost cycle hot dry air should be coming out of the outlet grill Unit does not Is the plug properly Insert the plug into the socket and turn operate inserted in the socket the switch on 13 Dehumidifier does not extract water Airflow weak Unit is noisy during operation Humidity set lower than the room humidity and unit not extracting Does the tank full indicator is red Is the unit set to a humidity level lower than the one in the room Is the temperature too low for water extraction to be efficient Is any intake grill or discharge blocked Is the unit too close to walls Humidity sensor error Tank full float displaced or tank not properly inserted Empty tank check float and make sure tank is properly inserted in unit Set the humidity level on the humidistat bellow current humidity reading Increase temperature in the room or reposition the unit Remove obstructions and restart the unit Ensure a distance of at least 20 cm between the unit amp walls seems Is filter dirty or clogged Please service the filters regularly as per user manual Is the unit on uneven Please place on flat horizontal surface surface Is filter clogged Please service the filters regularly as per user manual Unplug the unit and plug it back in error repeats call for service centre Inco
8. dified by a qualified electrician e This dehumidifier has been tested and is safe to use However as with any electrical appliances use it with care e Disconnect the power plug from socket before dismantling assembling or cleaning e Avoid touching any moving parts of the appliance e Never insert fingers pencils or any other objects though the guard e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety e Do not leave children unsupervised with this appliance e Do not clean the unit by spraying it or immersing it in water e Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician e Never operate this appliance if the cord power adapter or plug is damaged Ensure the power cord is not stretched or exposed to sharp object edges e A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard e Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to comply could result in a voided warranty e Do not use the appliance for any oth
9. earlier Combined with any other settings select the baiia key to achieve the balance between highest amount of humid air being processed high air low fan light on HI and quiet operation low fan speed fan light on LO Intelligent dehumidification and power saving Your ElectriQ dehumidifier features an intelligent micro CPU that ensure maximum water extraction with minimum power use for the selection made 8 The unit will try to maintain humidity level selected in the space where is placed by turning off the compressor when the desired humidity is reached Note that according to the size of the enclosed environment where is used obstacles in the direct flow extra humidity being added in the settings selected as well as other environmental factors the results may vary Other features and Indicators Tank Full Light Yo red light will be on and the unit will beep when the tank is ready to be emptied or when the tank is removed or not replaced in the proper position The water level control switch shuts off the dehumidifier when the tank is full or when the tank is removed or not replaced in the proper position Empty to resume normal operation Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the unit will go in defrost mode When the unit is running in a room with temperature between 5 C and 12 C unit may enter the defrost mode about once every 30 minutes When the unit is run
10. er purposes than its intended use e Do not tilt the unit while in use The unit is designed to work only in vertical position e This dehumidifier must always be stored and transported upright otherwise irreparable damage may be caused to the compressor if in doubt we suggest waiting at least 24 hours before starting the unit e Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off This prevents damage to the compressor e Never use the mains plug as a switch to start and turn off the dehumidifier Use the 2 provided ON OFF switch located on the control panel e Always place the unit on a dry and stable surface e The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85 RH e Do not dry laundry above the unit to prevent water entering the dehumidifier Place the laundry at least 1 meter away from your dehumidifier e Do not place the unit next to heat sources e g electrical fires fireplaces etc e Avoid mishandling the dehumidifier Dropping throwing the unit can cause damage to its internals and increases the risks of operating it e Do not store or use gasoline petrol paint solvents or other flammable vapors or liquids in the vicinity of this dehumidifier or any other appliance e This dehumidifier must not be used in spaces where there is a high concentration of gases solvent or other volatile organic compounds in very dusty environments in any do
11. mestic commercial or industrial environment where air composition is flammable Energy Saving and Unit Safety Protection Tips e Do not cover or restrict the airflow from the outlet or inlet grills e For maximum performance the minimum distance from a wall or objects should be 30 cm e Keep the filters or grills of the unit clean Under normal conditions filters or grills should only need cleaning once every three weeks approximately Since the filters remove airborne particles more frequent cleaning maybe necessary depending on the air quality Vacuum and wash the mesh filters with hot soapy water and dry them before placing them back in the unit Quick visual guide on where not to use your dehumidifier Exposed to the Near water If ther power cable Where small children weather outdoors wires are frayed or cut may be left unattended If an extension lead Where the power cable On a slope or uneven Where there is risk may become may be damaged surface of fire or close to overloaded a naked flame Where it may be Where there is a risk This product is not If there is a risk damaged by or interference by made for DIY repair of water falling on chemicals foreign objects the unit Features Your ElectrIQ dehumidifier belongs to the ElectriQ Pro range domestic commercial of dehumidifiers featuring best combination of 1 Efficient easy to use to use controls 2 Great for larger living areas such as spacious flats offices and h
12. ning in a room with temperature between 12 C and 20 C unit may enter the defrost mode about once every 45 minutes Normal operation will resume after defrost mode We advise not to use the unit in unheated rooms where temperature can go close or below 5 C as the evaporator at the back of the unit may freeze and damage the unit Humidistat control and fan compressor operation When the selected humidity is lower by than the user selected humidistat setting the dehumidifier s compressor will be shut off automatically but the fan will still move to ensure air is not stale in the room The unit will use only a minimal amount of energy in fan mode When the humidity is going back to being equal or higher than user selected humidity the compressor will restart once the 3 minutes delay compressor protection expires Power After the unit has stopped it is not recommended to resume operation in the first at least 10 minutes This is to protect the compressor Operation can resume after this period lapse When the unit is restarted there is a 3 minutes delay before compressor will start Compact portable design and powerful extraction The ElectriQ PRO dehumidifier range is built to be compact and lightweight for its Capacity The casters on the bottom of the unit make it easy to move from room to room Your dehumidifier is an advanced micro CPU controlled devices able of self diagnostics The LCD display May also show the error and protections c
13. odes Positioning the dehumidifier A badly positioned dehumidifier will have little effect in effectively drying the place In positioning the dehumidifier please ensure circulation of air in not restricted around the unit Please observe figure on the left in installing the unit Allow at least 20 cm space around the unit D i Place the unit on a flat dry surface Use in an enclosed 24 cm area for maximum efficiency Close all doors windows to create an effective operating environment Do not css use outdoors Your ELECTRIQ dehumidifier will begin to protect your space from the harmful effects of excessive moisture as soon as it is turned on Excess moisture is dispersed throughout your home For this reason the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home A warm hallway or landing is an excellent position for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and moving it to a more central location at a later date For the most effective use run your dehumidifier with external doors and windows kept closed Please note the unit should not be placed directly against a radiator or other heat source When positioning your ELECTRIQ dehumidifier ensure that it is placed securely on a level surface clear of any ob
14. omes and for commercial applications Designed to complement any modern space Quiet and turbo fan speed selection Castors and recessed handles for improved mobility Intelligent CPU controlled digital humidistat with continuous mode 4 humidity settings 40 50 60 70 RH and room humidity and temperature display 7 Quiet vs turbo fan operation ensures the right balance between quiet operation and maximum dehumidification 8 24 hours stopping timer 9 Tank operation or permanent drainage option 10 Tank full alarm amp auto stop function 11 Antibacterial filter cleans the air a Applications Homes offices garages cellars and basements stores caravans museums libraries etc Installation Remove any water from the water tank before starting the unit In order to save energy do not open windows or doors while the unit is running Place the unit on a hard flat surface On first use run the unit continuously for 24 hrs on continuous mode To reduce noise levels Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running ElectriQ PRO dehumidifiers make use of compressor technology to extract water from the environment The compressor dehumidifiers are ideal for normal domestic office or commercial applications in heated spaces during the winter months and they operate very economically when temperatures are above 12 15 C PD30E PD45E are easy to move around on
15. rrect Temperature sensor error Unplug the unit and plug it back in If temperature error repeats call for service centre Unit regularly stops Tank full red light Unit is defrosting Water tank full notification Allow the unit to automatically defrost The protect will clear after the unit self defrosts Increase temperature in the room if this repeats too often Tank is full or is not in the right position Empty the tank and replace in the right position Any other malfunctions will need to be reported to ElectriQ service centre Do not attempt unauthorised repairs as these may invalidate the warranty 14 Technical data Model no PDESOE PDEAS Dehumidification capacity 45 L day 830 W 3 8 A 18 5 kg All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose this product as unsorted waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to participating sites run by their local councils Please remember that this equipment will be further handled during the recycling process so please be considerate when depositing your Ss equipment Please contact the local council for details of your local household
16. stacle that may limit the air movement Place the dehumidifier on a flat dry surface Note Do not force castors to move over carpet or uneven surfaces nor move the unit with water in the tank as it may tip over and spill water 10 Water Drainage When the water tank is full the unit will stop automatically When this happens the tank full red code will show on the control panel Compressor will turn itself off as well Note Only empty the water tank when is full or before moving or storing the unit There are two ways to dispense collected water Use the tank When the tank is full the unit will automatically stop running and the Full indicator light will flash Turn around the unit and slowly pull out the tank Grip the middle handle securely and carefully pull out straight so water does not spill Do not rest the tank on the floor because the bottom of the tank is uneven and tank will fall and cause the water to spill Empty the water tank and reinsert it into the dehumidifier The tank must be in place and securely seated for the dehumidifier to operate again The dehumidifier can be re started when the tank is restored in its correct position NOTES When you remove the bucket do not touch sensors or any parts which are situated behind tank Doing so may damage the product Be sure to push the tank gently all the way into the unit Banging the bucket against anything or failing to push it in securely into place may
17. waste recycling centres ElectriQ UK SUPPORT www ElectriQ co uk support ELECTRIQ UK SUPPORT Please for your own convenience make these simple checks before calling the service line Has the unit been standing upright for at least 2 hrs Is the unit plugged into the mains Is the fuse OK Switch the unit on and wait three minutes to see if the issue is resolved Check whether the water tank is full Have you followed the troubleshooting procedures If the unit still fails to operate call 0871 620 1057 or fill the online form Office hours 9AM 5PM Monday to Friday www ElectriQuk com Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE55 2FX If the unit still fails to operate call 0871 620 1057 or complete the online form Office hours 9AM 5PM Monday to Friday www ElectriQ co uk Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE 16
18. wing more moisture in the air press the humidity control key and set to a higher percent value e g 60 70 The humidity control key will cycle from 40 to 70 RH and back to CNT CNT Continuous Laundry Mode for the dehumidifier to operate continuously with humidistat disabled with maximum water extraction until the tank is full set the humidity level CNT Note that is permanent drainage pipe is fitted the unit will not stop operation Humidity set to 40 RH set to achieve room humidity of around 40 good for quick drying boost on initial run or emergencies not recommended for long normal operation in domestic office environment Humidity set to 50 RH recommended setting great for domestic operation and dry storage Humidity set to 60 RH great for personal comfort and applications where 50 RH is considered too dry Humidity set to 70 RH ideal for unoccupied properties or where economical run is needed without the need to go drier than 70 RH Timer Ormer 9 key enables 0 24 hours stopping timer This will remain unaffected if unit goes in defrost mode To cancel start press the timer key 9 function until timer is canceled When selecting 4 hours for example the unit will stop operating after 4 hours with selected humidity fan settings Tank full before the selected time will stop the unit This setting is ideal for drying laundry No selection made will mean the unit operates continuously subject to tank full stopping the unit