Home

SlimPAR™ 64 User Manual Rev. 4

image

Contents

1. SIMPAR 64 User Manual ST SATELLITE READY Value Innovation Performance Green Thinking TABLE OF CONTENTS Page 2 of 12 BElOre YOU BOO Discos 3 What is e o o r 3 oca o o 3 Text CONVENTIONS rr K nu nh my 3 FEE A c Ta C 3 DOcumentinto mal OM 77 siste 3 Product at a GIANG iento 3 A NOTOS aira i c ca 3 Slli i7s 2 0isriio in a a a a ts 5 FFOGUCE OV GIG W srera cite css dean cc aeecteca ct ctat oben chat as at abet satekatehenteeh obit 5 SUD a oe ee Oe om ene eMC Cea ee rere neem A4 5 o en 6 El e Eon a T antes 6 POWER GINKNO i 6 A re amar ere Pr an meer Sn eee PTT mn ee eee 7 ie A 6 nuatnsdoedakvDs a a a 7 ROOI AAA A O x13 se 7 E O 8 Gont l Panel OPerallOl ainia airada sra 8 MN O 8 Contigua ton DND 7 c 8 SIAMING AO ON OSS a a A add 8 Configuration Standalone n2 11121 1 1x vn cv ven 9 Sond ACHVE MOS danos 9 Automatic MIE DS 9 TIC MOI e a n6 ee EE E EA 9 CUSTON TO AMO CO aid A A a ER 9 Mastar EUA Os AAA 9 DMX Channel Assignments and Valu s cccoccccoccccncccnncccnnncnnnannnnanonarononcnns 10 EAN ee gels ted le ssl A ere ove dh E A end de Pai baton Genie 10 O AAA SN APENE TE A eae RE A eee ee ee meee 10 Technical Information iii acia 10 General Maintenance c QC HH ng nh km sa 10 Technical Specifications ung to da 11
2. The carrier is responsible for any damage incurred during shipping to this product or any part that shipped with it Therefore if the received merchandise appears to have damages caused during shipping the customer must submit the damage report and any related claims with the carrier not CHAUVET The customer must submit the report upon reception of the damaged merchandise Failure to do so in a timely manner may invalidate the customer s claim with the carrier For other issues such as missing components or parts damage not related to shipping or concealed damage the customer must make claims to CHAUVET within 7 days of receiving the merchandise World Headquarters United Kingdom amp Ireland CHAUVET CHAUVET Europe Ltd General Information General Information Address 5200 NW 108th Avenue Address Unit 1C Sunrise FL 33351 Brookhill Road Industrial Estate Voice 954 929 1115 Pinxton Nottingham UK Fax 954 929 5560 NG16 6NT Toll free 800 762 1084 Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Voice 954 929 1115 Press 4 Fax 954 756 8015 Email tech chauvetlighting com World Wide Web www chauvetlighting com Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk SlimPAR 64 User Manual Rev 4
3. e This product is for indoor use only To prevent risk of fire or shock do not expose this fixture to rain or moisture e Make sure there are no flammable materials close to the unit while operating e Always install this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces e Be sure that no ventilation slots on the unit s housing are blocked e Always disconnect this product from the power source before cleaning it or replacing the fuse e Make sure to replace the fuse with another of the same type and rating e If mounting this product overhead always secure it to a fastening device using a safety cable e The maximum ambient temperature Ta is 104 F 40 C Do not operate this product at higher temperatures e Inthe event of a serious operating problem stop using the unit immediately e Never try to repair this product Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center e Never connect this product to a dimmer pack e Make sure the power cord is not crimped or damaged e Never disconnect the power cord by pulling or tugging on the cord e Never carry this product from the power cord or any moving part Always use the mounting bracket e Always avoid direct eye exposure to the light source when this fixture is on Page 4 of 12 SlimPAR 64 User Manual Rev 4 2 INTRODUCTION Pr
4. lt gt 255 0 100 000 lt gt 255 0 100 Color Macros 000 lt gt 015 No function Overrides CH 1 3 016 gt 255 Color Macros 100 When CH 6 is between 032 223 000 255 0 100 000 lt gt 015 No function 016 amp 255 Slow fast 000 031 RGB mode 032 063 Pulse effect 0 100 064 gt 095 Pulse effect 100 0 096 gt 127 Pulse effect 100 0 100 128 159 Auto fade transition 160 191 Auto snap transition 3 colors 192 223 Auto snap transition 7 colors 224 gt 255 Sound triggering mode Dimmer 000 lt gt 255 0 100 0 Lo O O oa 3 CH Mode Channel Function Value Setting 4 2 3 000 lt gt 255 0 100 000 255 0 100 000 lt gt 255 0 100 5 TECHNICAL INFORMATION Dust build up reduces light output performance and can cause overheating This can General Maintenance Page 10 of 12 lead to reduction of the light source s life and mechanical wear To maintain optimum performance and minimize wear you should clean your lighting fixtures at least twice a month However be aware that use and environmental conditions could be contributing factors to increase the cleaning frequency To clean this fixture follow the instructions below Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface and vents Clean the LED transparent c
5. 2 of this manual The SlimPAR 64 may be mounted in any position provided there is adequate room for ventilation around it Before deciding on a location for this product always make sure that it will be easy to access the unit for maintenance and programming purposes Make sure that the structure onto which you are mounting this product can support its weight Please see the Technical Specifications section of this manual for weight information When mounting this product overhead always use a safety cable Mount the fixture securely to a rigging point whether an elevated platform or a truss When rigging this product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When power linking multiple fixtures you must always consider the length of the power linking cable and mount the fixtures close enough for the cable to reach them The bracket knobs allow for directional adjustment when aiming the fixture to the desired angle Only loosen or tighten the bracket knobs using your bare hands Using tools could damage the knobs The double bracket yoke mounting brackets feet also serve as floor support s or surface mounting When mounting this fixture on the floor make sure that the fixture and its cables are away from people and vehicles Mounting Clamp on P A ate 4 i SlimPAR 64 User Manual Rev 4 Page 7 of 12 A
6. OPERATION Control Panel To access the control panel functions use the four buttons located underneath the display Please refer to the Product Overview page 5 to see the buttons location on the Operation control panel Button Function MENU gt Press to find an operation mode or to back out of the current menu option lt UP gt Press to scroll up the list of options or to find a higher value lt DOWN gt Press to scroll down the list of options or to find a lower value lt ENTER gt Press to activate a menu option or a selected value Menu M ap Mode Programming Steps Description PoP Z color program switching PR 7 color program fading o P8 8c lor program switching PP 3colorprogram fading PPB 7 color program sound active PPK 8 clo program sound active 3 CH d001 d512 3 channel DMX mode RGB 7 CH 7 channel DMX mode Car Red Pa Green o B Blue C Cyan Static Cs Magenta es elo S Program speed for P1 P4 ss SS Custom Static Colors u E __ Green 9000190 Combine red green and blue Blue b000 100 x Set this product in DMX mode to control it with a DMX controller Configuration 1 Connect this product to a suitable power outlet DMX 2 Turn this product on 3 Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product Starting Address When selecting a starting DMX address always consider the number of DMX channels the selected DMX m
7. before replacing the fuse 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder and pry it out of its housing 2 Remove the blown fuse from its holder and replace it with a fuse of the exact same type and rating 3 Insert the fuse holder back in its place and reconnect power Installed fuse held by plastic clip ov Safety cap I Spare fusel ee 4 inside safety cap _ This product ships with a spare fuse inside the safety cap as shown above Power Linking This fixture provides power linking via the Edison outlet located in the front of the unit Please see the diagram below for further explanation 1 Fixture 2 Fixture 3 Fixture Power Linking I I I I I I I Diagram Other fixtures You can power link up to 40 SlimPAR 64 units on 120 VAC or up to 60 SlimPAR 64 units on 230 VAC The power linking diagram shown above corresponds to the North American version of this product ONLY If using this product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your country or region Page 6 of 12 SlimPAR 64 User Manual Rev 4 Mounting Orientation Rigging l N L 1 Mounting Diagram Double Bracketed zz Yoke un a Safety Cable Before mounting this product read and follow the safety recommendations indicated in the Safety Notes section page
8. more SlimPAR 64 units the slaves without the need of a DMX controller The master unit will be set to operate in either Automatic or Sound Active mode while the slave units will be set to operate in Slave Mode Once set and connected the slave units will operate in unison with the master unit Configure the units as indicated below Slave units 1 Press lt MENU gt repeatedly until 3 CH or 7 CH shows on the display 2 Press lt ENTER gt to accept 3 Use lt UP gt or lt DOWNS to set the starting address to d001 4 Press lt ENTER gt 5 Connect the DMX input of the first slave unit to the DMX output of the master unit 6 Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit 7 Finish setting and connecting all the slave units Master unit 1 Set the master unit to operate in either Automatic or Sound mode as previously indicated 2 Make the master unit the first unit in the DMX daisy chain SlimPAR 64 User Manual Rev 4 Page 9 of 12 i Configure all the slave units before connecting the master unit to the DMX daisy chain Never connect a DMX controller to a DMX string configured for Master Slave operation because it may interfere with the signals from the master unit Do not connect more than 31 slave units to the master unit DMX Channel Assignments and Values 7 CH Mode 1 2 3 Channel Function Value Setting 000 lt gt 255 0 100 000
9. A o A 6 12 E A O a a RR 12 co EEA A oe ae C nh con nan 12 SlimPAR 64 User Manual Rev 4 1 BEFORE YOU BEGIN What is Included Unpacking Instructions Text Conventions Icons Document Information Product at a Glance Safety Notes A SlimPAR 64 User Manual Rev 4 e 1x SlimPAR 64 e 1x Power Cord e 1x Warranty Card e 1x User Manual Immediately upon receiving this product carefully unpack it and check the container in which you received it Make sure that you have received all the parts indicated above and that they are all in good condition If the material inside the container this product and any other accessory included with it appears damaged from shipping or if the container shows signs of mishandling notify the shipper immediately In addition retain the container and all the packing material for inspection See the Claims section in the Technical Information chapter Convention Meaning lt Menu gt A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Claims A section or chapter in this document Settings A menu option not to be modified for example showing the operating mode current status Menu gt Settings A sequence of menu options to be followed ON A value to be entered or selected Icon Meaning Critical installation configuration or operation information Failure to comply with this informa
10. g Voltage Selection Auto ranging 230 V 50 Hz 36 W 0 16 A 10 A 60 units F 1 A 250 V UK Europe IEC IEC Local plug Lifespan 100 000 hours Current 20 mA 20 mA 20 mA Channel Range 37 Item Number SLIMPAR64 UL 1573 CSA C22 2 No 166 E113093 Page 11 of 12 Returns E L Claims Contact Us Page 12 of 12 Send the merchandise prepaid in the original box and with its original packing and accessories CHAUVET will not issue call tags Call CHAUVET and request a Return Merchandise Authorization RMA number before shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return The user must clearly label the package with a Return Merchandise Authorization RMA number CHAUVET will refuse any product returned without an RMA number DO NOT write the RMA number directly on the box Instead write it on a properly affixed label Once you have received the RMA number please include the following information on a piece of paper inside the box e Your name e Your address e Your phone number e The RMA number e A brief description of the problem Be sure to pack the fixture properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility FedEx packing or double boxing are recommended CHAUVET reserves the right to use its own discretion to repair or replace returned product s
11. ode uses If you choose a starting address that is too high you could restrict the access to some of the fixture s channels The SlimPAR 64 uses up to seven DMX channels in the 7 CH personality which defines the highest configurable address to 507 If you are not familiar with the DMX protocol www chauvetlighting com To select the starting address do the following 1 Press lt MENU gt repeatedly until 3 CH or 7 CH shows on the display Press lt ENTER gt 3 Use lt UP gt or lt DOWN gt to select the starting address d001 d507 Press lt ENTER gt download the DMX Primer from Page 8 of 12 SlimPAR 64 User Manual Rev 4 Set this product in one of the standalone modes to control it without a DMX controller Configuration 1 Connect this product to a suitable power outlet Standalone 2 Turn this product on Never connect a fixture that is operating in any standalone mode whether Static i Automatic or Sound to a DMX string connected to a DMX controller This is because fixtures in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller i To enable the Sound Active mode do the following Sound 1 Press lt MENU gt repeatedly until P shows on the display OGe 2 Press lt ENTER gt 3 Use lt UP gt or lt DOWN gt to select P5 or P6 4 Press lt ENTER gt 5 Turn the music on and adjust the microphone sensitivity knob until the fixture star
12. oduct Overview Control Panel LED Display Satellite 12 V Input Microphone Sensitivity Adjustment Knob ower In Min Max Sensitivity D El OO Ooo O MENU UP DOWN ENTER OO Mic oS DMX In DMX Out Fuse Holder 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 00000000000000 Power Out Bracket Adjustment Knob SlimPAR 64 User Manual Rev 4 Page 5 of 12 3 SETUP This product has an auto ranging power supply and it can work with an input voltage AC Power range of 100 240 VAC 50 60 Hz To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect this product to a protected circuit circuit breaker or fuse making sure that it has an appropriate electrical ground to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Or Fuse This fixture uses an F 1 A 250 V fuse Follow the instructions below to change it in case it blows Replacement AN Disconnect this product from the power outlet
13. over with a mild soap solution ammonia free glass cleaner or isopropyl alcohol Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue Softly wipe any dirt or grime to the outside edges of the LED transparent cover Gently polish the transparent LED cover until it is free of haze and lint i Always dry the transparent LED cover carefully after cleaning SlimPAR 64 User Manual Rev 4 G TECHNICAL SPECIFICATIONS Dimensions and Weight Power Light Source Photo Optic Thermal DMX Ordering Length 9 7 in 246 mm Power Supply Type Switching internal Parameter Power Operating current Power linking current units Fuse Power I O Power input connector Power output connector Power Cord plug Type LED Color Red Green Blue Parameter lluminance O 1 m llluminance 2m Beam angle Field angle Maximum External Temp 104 F 40 C I O Connectors 3 pin XLR Product Name SlimPAR 64 SlimPAR 64 User Manual Rev 4 11 1 in 282 mm Height 2 5 in 64 mm Note Dimensions in inches rounded to the nearest decimal digit Range 100 240 V 50 60 Hz 120 V 60 Hz 32 W 0 28 A 10 A 40 units F 1A 250 V US Worldwide IEC Edison Edison US Power 14 W Quantity 60 60 60 Value 3 640 lux 1 241 lux 142 23 Cooling System Convection Connector Type Sockets ltem Code 03030271 C us Weight 2 8 Ibs 1 3 k
14. tion may render the fixture partially or completely inoperative cause damage to the fixture or cause harm to the user Important installation or configuration information Failure to comply with this information may prevent the fixture from functioning correctly Useful information LIS gt The information and specifications contained in this document are subject to change without notice CHAUVET assumes no responsibility or liability for any errors or omissions that may appear in this manual Copyright 2012 CHAUVET All rights reserved Printed in P R C Electronically published by CHAUVET in the United States of America Use on Dimmer Auto Programs Y Outdoor Use Auto ranging Power Supply Y Sound Activated Replaceable Fuse v DMX User Serviceable OQ Master Slave Duty Cycle OQ Please read the following notes carefully before starting to work with this product They include important safety information about its the installation usage and maintenance Please read the following notes carefully because they include important safety information about the installation usage and maintenance of this product e Keep this User Manual for future consultation If you sell this product to another user be sure that they also receive this document e Always make sure that the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the fixture Page 3 of 12
15. ts reacting to the beat of the music Ei The fixture will only respond to the low frequencies of the music bass and drums To enable the Automatic Mode follow the instructions below P H P0 i 1 Press lt MENU gt repeatedly until P shows on the display 2 Press lt ENTER gt 3 Use lt UP gt or lt DOWN gt to select P1 P4 4 Press lt ENTER gt 5 Press lt MENU gt repeatedly until S shows on the display 6 Use lt UP gt or lt DOWN gt to adjust the speed at which the program plays S001 100 7 Press lt ENTER gt i To enable the Static mode do the following Static Mode 1 Press lt MENU gt repeatedly until C shows on the display 2 Press lt ENTER gt 3 Use lt UP gt or lt DOWNS to select the preset color C1 C7 4 Press lt ENTER gt To enable the Custom Static Colors mode do the following c 1 Press lt MENU gt repeatedly until U shows on the display 2 Press lt ENTER gt 3 Use lt UP gt or lt DOWN gt to select the desired color red r green g or blue b 4 Press lt ENTER gt 5 Use lt UP gt or lt DOWN gt to select the desired color value 000 100 NOTE Selecting 000 will turn the color off 6 Press lt ENTER gt to continue to the next color 7 Repeat steps 5 to 7 until you create your desired color 8 Press lt ENTER gt to save the color Master Slave This mode allows a single SlimPAR 64 unit the master to control the actions of one Mode

Download Pdf Manuals