(SAVE THESE INSTRUCTIONS)

image

Contents

1. HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Insure that the equipment plugged into the battery power supplied outlets does not exceed the UPS unit s rated capacity 600VA 360W for Value 600ELCD 800VA 480W for Value 800ELCD 1000VA 550W for Value 1000ELCD If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the fuse blow 2 If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of 1 Circuit Breaker below value The circuit breaker provides optimal overload protection TO ESTIMATE POWER REQUIREMENTS 2 AC outlet The UPS provides 2 outlets for connected equipment to insure temporary uninterrupted operation 1 Amps A x 230 VA during a power failure and against surges and spikes 3 AC Inlet 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual C i Spas 4 requirements There are many factors that can affect the amount of power that your computer system ONECIE TINNY POWT MOUGN ME IMPUE POWETLON a n total ja that you will be placing on the battery powered outlets should not exceed 4 Seria
2. Cy berPower Reliability Quality Value 3 Charge the Battery Your new UPS may be used immediately upon receipt However charge loss may occur during shipping and storage So charging the battery for at least 8 hours is recommended to insure that the battery is fully charged To recharge the battery simply leave the unit plugged into an AC outlet This UPS can be charged even when UPS is not turn on WAGE les 4 Connect to AC Connect the UPS to a wall outlet Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS plugged in at all times oS ejeje Go edesea fesse fecSes il v O 5 Connect the Load Connect the equipment to your UPS outlets Items such as copiers laser printers vacuums space heaters or other large electrical devices SHOULD NOT be connected to the UPS Please make sure that the total loads of your equipments are less than the maximum total power load of your UPS 6 Connect to Computer Install your software and accessories To use the software simply use the enclosed serial interface Value 600ELCD 800ELCD 1000ELCD or USB cable to connect the UPS unit and your computer User s Manual Rev A BASIC OPERATION SAFETY WARNINGS SAVE THESE INSTRUCTIONS FRONT PANEL DESCRIPTION This manual contains important safety instructions Please read and follow all instructions carefully or during i
3. Windows 98 ME 2000 NT XP Vista 7 N Jo a wn DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD Indication LOAD BATT CAP INPUT OUTPUT RUN_TIME San y 20 2 Line mode UPS Status Display Capacity Display Digital Value Display Press gt 3sec again Sound Enable Overload V Illuminated X Not Illuminated gt Either Battery mode UPS Status Display Capacity Display Digital Value Display Battery Input Output Run Cap Voltage Voltage Time of Load of Batt Es ee eee eee V Press gt 3sec again Sound Enable Overload X Not Illuminated V Illuminated Either Visit www cpsww com for more product information and the nearest CyberPower local contact for your region Entire contents copyright 2011 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited A CE Z Pb Free lt
4. dem fax telephone line FUNCTIONAL TEST AC Mode The UPS delivers power to the loads derived from the utility and maintains proper battery charge It also regulates the output voltage to within a narrow range On Battery Mode The UPS operates on battery when the line voltage or frequency has fallen outside the limits Local users are alerted to this mode of operation by visual and audible indicators The UPS provides power to the load from the battery and through its inverter and the output voltage and frequency of the UPS are regulated within a narrow range 1 Switch On Press the power switch on the front panel then the status LCD will light up 2 Switch Off Press again the power switch the status LCD on the front panel will go off 3 Cold Start Start on Battery This UPS can be turned on even when AC is not present Press the power switch on the front panel then the status LCD will light up ROUTINE MAINTENANCE AND STORAGE ROUTINE MAINTENANCE 1 Use dry soft clothes to clean the front panel and plastic parts Do not use any detergent that contains alcoholic ingredient na The expected lifetime of the battery is around 3 years Improper operation and harsh environment will reduce the actual lifetime 3 Unplug the UPS from power inlet if the UPS will not operate for long period of time STORAGE 1 First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected the UPS t
5. e is PowerPanel connected to the wrong Personal Edition port is inactive all icons are gray Try another serial USB port of your computer Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit The unit is not providing battery power The serial cable is not the cable that was provided with the unit You must use the cable included with the unit for the software TECHNICAL SPECIFICATIONS Value 600ELCD Value 800ELCD Value 1000ELCD 600VA 800VA 1000VA 360W 480W 550W 47 63Hz Auto Sensing Capacity VA Capacity Watts Input Frequency Range Output On Battery Output Voltage On Battery Output Frequency Overload Protection Physical Total of UPS Receptacles Maximum Dimensions Weight Battery Sealed Maintenance Free Lead Acid Battery Typical Recharge Time Warning Diagnostics Indicators Simulated Sine Wave at 230Vac 10 50 60 Hz On Utility Circuit Breaker On Battery Internal Current Limiting 2 Shuko 32cm L 10cm W 14cm H 5 8 kg 12V 9AH 8 Hours 5 2 kg 6 1 kg 12V 7AH 12V 9AH Power On UPS Status Display Capacity Display Digital Value Display Audible Alarms On Battery Low Battery Overload Fault Environmental Operating Temperature Operating Relative Humidity Communication PowerPanel Personal Edition Software Management Auto Charger 32 F to 104 F 0 C to 40 C 0 to 95 NON CONDENSING
6. l Port to PC i a an S This port allows connection and communicates from the DB 9 serial on the computer to the HARDWARE INSTALLATION GUIDE j UPS unit The UPS communicates its status to the PowerPanel Personal Edition software This interface is also compatible with the UPS service provided by Windows 98 Windows ME 1 Placement Windows NT Windows 2000 Windows XP Windows Server 2003 Windows Vista Windows 7 Before installation please read and understand the following instructions The UPS must be installed in a protected environment away from heat emitting appliances such as a radiator or heat register Do not install this product where excessive moisture is present 5 USB Port to PC This port allows connection and communication from the USB port on the computer to the UPS unit The UPS communicates its status to the P 4 PowerPanel Personal Edition software This w 40 4 interface is also compatible with the UPS service ne 6 provided by Windows 98 Windows ME Windows NT Windows 2000 Windows XP Windows Server 2003 Windows Vista Windows 7 NOTE Only one of these two ports can be used as communication and control of the UPS unit at one time 2 Ventilation The location should provide adequate air flow around the UPS with one inch minimum clearance on all sides for proper ventilation 6 Communication Protection Ports Communication protection ports will protect any standard mo
7. nstallation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS This equipment can be operated by any individuals with no previous training H The socket outlet shall be installed near the equipment and easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains 1 LCD Function Selected Switch hazardous voltage still may be accessible through supply from battery The battery supply should be mer eh cisconmecied n H es ah Aa aline quicr connectors Q te patery When The switch can be used to select the LCD display contents including input output voltage maintenance or service work inside the is necessary ahd estimated finan cic Do not dispose of batteries in a fire the battery may explode Do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes ie SWEN l Press the power switch to turn the UPS ON or OFF INSTALLING YOUR UPS SYSTEM 3 LCD Status Monitor UNPACKING REAR PANEL DESCRIPTION Inspect the UPS upon receipt The box should contain the following UPS Unit x 1 USB Cable x 1 User Manual x 1 Management Ssoftware Disk x 1 Warranty Card x1
8. o avoid battery drain 2 The UPS should be stored in a cool dry location 3 Make sure the battery is fully charged before the UPS is stored 4 For extended storage in moderate climates the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch Repeat it every 2 months in high temperature locations TROUBLE SHOOTING Problem Possible Cause Solution The UPS does not perform expected runtime Batteries are not fully Recharge the battery by leaving the UPS charged plugged in l Contact CyberPower Systems at The unit is not connected to The unit must be connected to a an AC outlet 220 240V 50 60Hz outlet Contact CyberPower Systems at Contact CyberPower Systems at service cyberpower eu com Turn the UPS off and unplug at least one piece connected equipment Unplug the power cord of the UPS then press the circuit breaker knob Batteries are discharged Ser unit to recharge for at least 4 Unit has been damaged by Contact CyberPower Systems at a surge or spike service cyberpower eu com Connect the serial USB cable to the UPS The serial USB cable is not unit and an open serial port on the back connected of the computer You must use the cable that came with the unit The UPS will not turn on Mechanical problem Circuit breaker is tripped due to overload Outlets do not provide power to equipment The serial USB cabl