1. TECHNICAL DETAILS e eurorack standard synthesizer module fully Doepfer compatible e 6hp wide e 12 12V powered e current draw 30 mA Y io aa APPROVED BY THE PEOPLE S COUNCIL FOR MUTUAL ECONOMIC AID WARRANTY INFORMATION XAOC DEVICES WARRANTS THIS PRODUCT TO BE FREE FROM ANY CONSTRUCTION DEFECTS FOR ONE YEAR FROM THE DATE OF PURCHASE DURING THAT PERIOD ANY MALFUNCTIONING UNITS WILL BE REPAIRED SERVICED AND CALIBRATED WITHOUT CUSTOMER COVERING THE APPROPRIATE TRANSIT FEES e WARRANTY DOES NOT COVER ANY PROBLEMS RESULTING FROM THE INCOR RECT INSTALLATION OR VOLTAGE SUPPLIED ABUSIVE TREATMENT OR ANY OTHER OBVIOUS USER NFLICTED FAULT WE ARE STILL HAPPY TO HELP AFTER THE WARRANTY PERIOD HOWEVER WE RESERVE THE RIGHT TO CHARGE FOR LABOR REPLACEMENT PARTS AND TRANSIT IN CASE OF ANY PROBLEM PLEASE CONTACT US IMMEDIATELY INFO XAOCDEVICES COM e XAOC SALUTES MUFF WIGGLERS COMMUNITY OUR AWESOME DISTRIBUTORS NORDVARGR B SMITH J LINDGREN B VAN DER WAL MODULARNE INFO amp COMRADES WORLDWIDE e ALL RIGHTS RESERVED 2014 XAOC DEVICES e MANUFACTURER RESERVES THE RIGHT TO CHANGE SPECIFICATIONS AT ANY TIME MADE IN EUROPE XAOCDEVICES COM
2. M Stay aya 00 SALUT Thank you for purchasing the Xaoc Devices product The Tirana module comes in handy as a classic step sequencer modulation source voltage bank arpeggiator etc serv AA PR HE gt ing as the utility module for supporting other sequencers but it also shines on its own terms Due to smart features to be described in this manual Tirana provides a number of very interesting possibilities and turns out to be surpris OPERATOR S MANUAL 60 1 2 ingly powerful module while preserving the ease of use and minimal real estate in the system It is only 6hp and therefore a perfect solution for compact and portable modular setups but can empower just any system to a great extent THE MODULE EXPLAINED PANEL CONTROLS gt LTT C e TIRANA 1960 UTILITY MICRO SEQUENCER STE P Lii UNIPOLAR Ov UNIPOLAR VOLTAGE BIPOLAR UNIPOLAR 10y by BIPOLAR VOLTAGE r BIPOLAR Ov 5y GETTING STARTED Clear 6hp space in your eurorack cabinet and turn the power off Ensure that the jumper on the 1N header re mains in place for single unit operation for multiplied setups read the instructions further down in the manual Now plug in the ribbon cable to the bus board observing the red stripe orientation Tirana has been secured against reversed power connection but it is always a good habit to pay attention t
3. le set in your cabinet Don t forget about powering every single Tirana unit SUGGESTED PATCHES e Build a 8 12 16 32 and lon ger step sequencer subsystem using multiple Tiranas The first unit in a linked chain acts as the master and this is where all the patch cables should be fed The mutes and repetitions work for each slave unit independently e Use one Tirana to transpose the other one unlinked for a pseudo arpeggio effect Use different divisions of the same clock and step repeat function e Let one Tirana trigger the re set or direction change function of another unit unlinked e Use a couple of unlinked Ti ranas for complex sequencing feed them different clocks com bine their trigger outputs with Xaoc Bytom and CV outputs with Xaoc Warna mixer e Make the trigger output a source of complex clock for another Tirana e Tirana comes in handy as an utility clock divider Feed a clock and adjust the same repeat setting on every step Division is available at the trigger output PRODUCT FEATURES e 4 steps of pitch and trigger impulse generation e step repetition up to 4 note events per step g EA e unipolar and bipolar voltages g PEACE Pa N M e mutable trigger per step N I e playback direction change via CV e sequence trasposition via CV e sequence reset via CV e backward power protection e expandability via chaining up more Tirana units together
4. o this Mount the screws and turn your system back on CONTROLS amp OPERATION In order to operate an external clock needs to be fed to the CLOCK input usually the pulse from a LFO or any clock generator of choice Steps will now be played subsequently in a loop Adjust the desired pitch by turning knobs Generated pitch and trigger voltages are available at cv our and TRIG GER sockets Each step may now be removed from the sequence muted by pressing the corresponding button Please note that only the TRIGGER output is being muted the pitch voltage is available as usual The sequence direction can be changed by feeding a trigger impulse into the DIRECT input To reset the sequence a trigger needs to be fed into the RESET input The sequence can be also transposed offset by provid ing control voltage into the TRANSP input jack CHAINING UP UNITS et 1 205 l B MULT UNT O e O UNIPOLAR BIPOLAR Remove the jumper from every module but master Then attach supplied cables exactly as shown on the picture MULTI UNIT MULTI UNIT HEADERS HEADERS KEEP THE KEEP THE oo peas J oo oo ALONE A AU oo ef z UNIPOLAR C nIm 7 p N z POWER CONNECTOR STEP REPEAT Each step can be repeated up to 4 times resulting in up to 16 steps in the sequence To set a desired number of repeats for a given ste
5. p hold its mute button down for approx 2 seconds until the menu mode is confirmed by all buttons dimmed for a moment Then push the BUTTON NO 2 for one repetition 2 note events BUT TON NO 3 for double repetition 3 events or BUTTON NO 4 for triple repetition of the given step 4 events To reset the desired step to generate just one note push BUTTON NO 1 SETTING THE POLARITY Tirana ships set to unipolar o to 10 V mode as most users will probably want to use it as a melody generator Still the module makes a great modula tion source when set to bipolar 5 to 5V operation To adjust the desired mode simply set the jumper on the back of the module MULTIPLE TIRANA SETUPS You can easily chain up a number of Tirana units together to open up a lot of interesting possibilities Every Tirana ships with one 10 pin ribbon cable and a loop wire Attach them exactly as shown on the picture First every slave unit requires jump ers to be removed these are required for single unit opera tion Then every ribbon should connect the out header of the master unit with the In header of slave unit The first unit in a chain should only have the out header occupied The single wire cable needs to connect the lowest left pin of the IN header on the master unit and the same lowest left pin of the out header on the last slave unit in a chain Please double check that if it is mounted correctly and put the who
Download Pdf Manuals
Related Search
Related Contents
45°-50° 40° 15° Description et mode d`emploi des cartes pluviométriques usuelles 10100120-B BK Tec Note Leveling the Printer Using the Theodolite Carrera 10118 option profibus ダウンロード ALL-Ways 14.0 User`s Manual ばれいしょ茎葉処理機 SY-RET30_ Portugês LG 49LF6300 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive Copyright © All rights reserved.