1. Drawing no E_c Page 3 of 4 Nome Executinc Dote 04 10 29 Emy Revise 1 04 11 15 Emy General Guideline for execution of exterior ventilated Fibre Cement cladding Dansk Eternit Holding DEH MAX LENGTH OF NOT SUPPORTED BOARD PANEL Max length of not supported by stud board panel Wood max 45 mm and min distance to edge of wood 25 mm Steel max 55 mm and min distance to edge of steel 15 mm Alu mox 55 mm and min distance to edge of alu 15 mm Stud Rubber 000 Board Panel o ATTACHMENT OF BOARD TO STUDS Please remember that it s NOT allowed to attach one board to two studs see the below sketches NOT ALLOWED ALLOWED COMPLETION OF WORK Check that the facade cladding is clean and without damage defects or omissions Make sure that any waste is cleared up following completion of the work Give the user s manual to the client and review it with him in detail The boards are moving with climate changes therefore they might bend Drawing no E_d Page 4 of 4 Dote 04 10 29 Revise 1 04 11 15 6 mm General Guideline for execution of exterior ventilated Fibre Cement cladding Dansk Eternit Holding DEH Technical Service Centre TSC is hereby giving the general quidelines basic rules for fastening DEH external ventilated boards item a to the direct under laying studs item b DEH e
2. Wood 25 mm Steel ond olu 30 mm 70 mm Max 625 mm Fixed attachment on steel or alu Fixed attachment of steel or alu studs to the structural facade see also the Drawing named Fastening The fixed attachment may here be max 50 mm over under the centre line of the boord the fixed attachment may here be max 200 mm over under the centre line of the board Drawing no ATT_b Page 2 of 4 Nome Attoching_b Date 04 10 29 General Guideline for attaching boards and studs on external ventilated FC cladding Dansk Eternit Holding DEH Board thickness up to 6 mm Vertical plane Boards are here 1200x2500 mm Wood 25 mm Steel and alu 30 mm 70 mm Max 425 mm Fixed attachment on steel or alu Fixed attachment of steel or alu studs to the structural facade see also the Drawing named Fastening The fixed attachment may here be max 50 mm over under the centre line of the board The fixed attachment may here be mox 200 mm over under the centre line of the boord Drawing no ATT_c Page 3 of 4 General Guideline for attaching boards and studs on external ventilated FC cladding Dansk Eternit Holding DEH Nome Attoching_c Dote 04 10 29 EMJ Board thickness over 6 mm Vertical plane Boards here 1200x2500 mm wood 25 mm Steel and olu 30 mm 70 mm Max 625 mm Fixed attach
3. here shown in the middle so that movements in the horizontal and vertical directions are eliminated The other attachments dilatations points of the STEEL or ALU studs onto the structural facade have to allow movements in the vertical direction but not in 0000 the horizontal direction Regarding wood please see the Drawings named Wood_Nails or Wood_Screws Boards are installed in the vertical plane Please also see all pages in the Drawing nomed Attaching Page 2 of 2 pote 03 05 14 Emy EMJ General Guideline for fastening exterior ventilated Fibre Cement cladding 5 Boord thickness op to 6 mm Vertical plone Boards are here 1200x2500 mm Wood 25 mm Steel and alu 30 mm 70 mm Mox 425 mm Fixed attachment on steel or alu Fixed attachment of steel or alu studs to the structural facade see also the Drawing named Fastening The fixed attachment may here be mox 50 mm over under the centre line of the board The fixed attachment may here be max 200 mm over under the centerline of the board Drawing no ATT_o Page 1 of 4 Nome Attoching_o Date 04 10 29 EMJ General Guideline for attaching boards and studs on external ventilated FC cladding A Dansk Etemit Holding DEH Board thickness over 6 mm Vertical plane Boards are here 1200x2500 mm
4. Installation Instructions for Cembonit amp Minerit RECEIPT AND INSPECTION It is the responsibility of the recipient to check that all goods received are free of damage and in accordance with the order submitted Any deviations must be specified in writing on the delivery note immediately after reciving receipt of the gods concerned A copy of the delivery note with ony remarks must be submitted to the driver Goods may only be returned as per agreement STORAGE AND HANDLING Flat panels boards must be handled with care and protected against dirt and precipitation both during transport and at the building site The panels must be stacked on a dry and level surface with the edges of the panels lying directly above each other The panels must always be stored under cover and covered with a protective material such as tarpaulin Flat panels that get wet on the pallet due to precipitation or condensation will have a tendency to precipitate calcium efflorescence Flat panels must always be lifted and not dragged off the stack Secure stacking of flat panels max 5 pallets and max 50 panels per pallet LAYOUT OF THE BUILDING SITE AND INSTALLATION PLANNING Access to the building site must be such that deliveries can be made by truck with or without a trailer Delivery at the building site with a crane must be ordered in advance and the products unloaded at the edge of the vehicle Extended storage of panels must take place in ven
5. ane e g facade up to 8 floors mox 400 mm distance over 8 floors max 300 mm distance By Board installed in horizontal plane e g ceiling and sofit max 300 mm Predrilled hole dilatation point using self drilling screw for steel stud 8 mm Predrilled hole for fixed fix point screw for steel stud 4 0 mm Screw CEM board DE flex facade screw stainless steel S TX25 4 8x25 mm Screw MIN PC board stainless steel wingscrew 4 2x32 mm O00 To be sure that the laws and regulations of each country region or project are followed it is necessary to make specific static calculations The screw in the centre of the board is to be fixed so the movement of the board relative to the steel stud is halved PS It is very important to remove dust from drilling and cutting immediately to avoid the dust from burning permanently to the board Drawing no S_S_o Page 1 of 2 Nome Steel_Screws_a Date 03 05 14 EMy Revise 2 04 10 29 EMJ General Guideline for installing exterior ventilated FC cladding on steel using screws Dansk Eternit Holding DEH Regarding General guideline for fastening to the structural facade construction please see all pages in the Drawing named Fastening Stud steel quality min S250GD 250 N mm2 Stud steel coating min Zinc 275 g m2 There has to be a running air gap of min 10 mm at each floor maxi
6. e stobility of the walls must be ensured without help from our products Our products must be able to move in order not to crock when the climate chonges Always install cladding in dry weather CUTTING THE PANELS The poneis can also be cut from the front side by a handsow with a finetoothed metoi blade When sharp edges are desired ond by large cutting jobs a high speed circular saw with diamond biade must be applied ond an aspirator must be connected We recommend a diamond blade with a grain size of 36 44 and a cutting edge Drowing na Eb General Guideline for execution of exterior Poge 2 of 4 ventilated Fibre Cement cladding Dansk Etemit Holding DEH 22 DRILLING OF HOLES always drill dry without liquid The drilling of holes must be done from the front of the panel The drilling of fixed holes is best done using a Joran UNIplus universal drill and a drilling speed of 1500 rpm Larger holes or cut outs on the ponel can be made by a jig sow with a carbide blade or by drilling a series of holes 5 mm apart after which the cut out can be removed with the strike of a hammer The cut out for a branch box etc can be done by a turning saw HHS bimetallic blade or diamond applied or by a circle cutter INSTALLING OF ATTACHMENTS The attaching is done in a spiral manner see also the sketch below Start attaching no 1 fixed point afterwards the dilation points starting with no 2 then 3
7. ment on steel or alu Fixed attachment of steel or alu studs to the structural facade see also the Drawing named Fastening The fixed attachment may here be max 50 mm over under the centre line of the board the fixed attachment may here be max 200 mm over under the centre line of the board E General Guideline for attaching boards and studs on external ventilated FC cladding Boord Cembonit CEM or Minerit Prisma Color MIN PC Dimension of steel Hat stud minimum 1 2x20 25 95 25 20 mm EPT rubber on steel stud CEM board 2 pieces of 30x3 mm EPDM TPE rubber on steel stud MIN PC board 2 pieces of 36x1 mm Stud joint air gap between two boards 5 10 mm see also page 2 Stud joint air gap between two steel studs min 10 mm Dim of steel Z stud min 1 2x40 25 30 mm EPT rubber on the steel stud CEM board 30x3 mm EPDM TPE rubber on the steel stud MIN PC board 36x1 mm Screw distance from edge poralle to the steel stud 30 mm 0000 Screw distance from edge perpendicular to the steel stud 70 mm 00O By Board installed in vertical plane e g facade Board thickness Stud c c distance up to 6 mm max 425 mm over 6 mm max 625 mm By Board installed in horizontal plone e g ceiling and soffit Board thickness Stud c c distance up to 6 mm mox 325 mm over 6 mm max 425 mm By Board installed in vertical pl
8. mum 3 05 m in order to ventilate the boards construction The screws are to be tightened with about 4 Nm but test the torque before setting the Nm otherwise you may destroy the boord because it will not have the possibility to move Please also see all pages in the drawings nomed Attaching and Excecution The screw DE flex S TX25 in the centre of the board is to be fixed therefore you HERE predrill the board with 4 0 mm If you have an equal number of spacers you just fix ONE of the two studs in the middle The fixed screw in the centre hos to be installed first afterwards the rest of the screws are installed in a spiral If you ore using MIN PC boards you also use the DE flex here Drawing no S_S_b Page 2 of 2 Steel_Screws_b Date 03 05 14 EMJ Revise 2 04 10 29 EMJ because the MIN screw is with wings General Guideline for installing external ventilated FC cladding on steel using screws Dansk Eternit Holding DEH
9. tilated storage buildings Accessories ancillary equipment must be stored so that it is not damaged and protected against dirt and precipitation Remember to cover all products for facade cladding at the end of the working day SAFETY Before installing panels the sofety conditions in relation to the task ot hand must be taken into account If required safety equipment such as scaffolding gangways boarding screens safety nets and similor must be established in a proper and usable manner before work is commenced Page 1 of 4 Dote 04 10 29 Emy Revice 1 04 11 15 EM Generol Guideline for execution of exterior ventilated Fibre Cement cladding VENTILATED CONSTRUCTION Our facade cladding is executed os a ventilated construction i e the outermost cladding is open in order to allow ventilation of an underlying cavity WIND BARRIER IMPERVIOUSNESS There is o wind barrier behind the facade cladding that is designed to make the strucure impervious to the weather and the wind as well as meeting the fire requirements with regards to the surfoce of the exterior wall As wind borrier the Minerit LW is an excellent choice INSTALLATION IN GENERAL In order to achieve o good result it s important that the cladding is installed on a stiff strong and fiat construction During installation the poneis must be handied with care ond not dragged or pushed over each other so that the surface are damaged Th
10. xternal boards are CEM Cembonit MIN HD Minerit HD MIN PC Minerit Prisma Color Consequently it has to be stated that the following items have to be observed as TSC isen t able to cover the specific laws and regulations in all countries The specific static calculations have to be done in each country region or each project according to the valid local laws and regulations check if the country region has specific rules regarding e g the use and type of pressure creosoted wood The statics ond fasteners to the structural facade constructions item c must to be done in each country region or each project according to applicable local laws and regulations The middle point fixed point of steel or alu studs has to be fixed to the structural facade see item d The other attachment points dilatations points of the studs to the structural facade hove to be installed in accordance with item e Drawing no F_o Page 1 of 2 Name Fastening_a Dote__ 03 05 14 EMJ 04 10 29 General Guideline for fastening exterior ventilated Fibre Cement cladding Dansk Etemi Holding DEH Board Cembonit CEM Minerit HD MIN HD or Minerit Prisma Color MIN PC Studs Do NOT mix between wood steel and alu studs Structural facade Construction The fixed points of STEEL or ALU spacers must be attached to the structural facade in the same HORIZONTAL level
Download Pdf Manuals
Related Search
Related Contents
H40® Eco Ideal Samsung SCX-8230NA Manual de Usuario Graco EZ Greaser User's Manual Philips AVENT Baby Bottom Balm SCF516/25 e+p F 20 cable splitter or combiner Phocos CIS-MPPT 85/20 Aquatic AI7242rc27 User's Manual Installation and user manual for the integrated washer Copyright © All rights reserved.