DAM-E3013 User`s Manual

image

Contents

1. Static DAM E3013 V6 40 2008 11 11 IP 192 168 2 80 Subnet mask 255 255 255 0 GateWay 192 168 2 1 MAC address f0 03 64 34 34 56 Communication Protocol At present Ethernet Distributed Acquisition Modules of our company use MODBUS TCP mode code includes the following categories Supported function DAM E3013 User s Manual V6 11 01 READ COIL STATUS 02 READ INPUT STATUS 03 READ HOLDING REGISTERS 04 READ INPUT REGISTERS 05 FORCE SINGLE COIL 06 PRESET SINGLE REGISTER 15 FORCE MULTIPLE COILS 16 FORCE MULTIPLE REGISTERS 20 READ FILE RECORD 21 WRITE FILE RECORD Address Mapping Table Read Switch Input Function Code 02 Description Read input switch status Data Description Address Description Note 10001 10016 For Switch Input Status 16 Channels 0 for no power 1 for power on Reservation 10033 10048 For Rising Edge Latched Status 16 Channels 0 for No Latch 1 for Latch Reservation 10065 10080 For Falling Edge Latched Status 16 Channels 0 for No Latch 1 for Latch Request Domain Name Byte Value Function Code 1 byte 0x02 Start Address 2 bytes 0 X 0000 to 0 X FFFF Read Amount 2 bytes 1 to 2000 0X 7D0 Response Domain Name Byte Value Function Code 1 byte 0X 02 Byte Count 1 byte N Read Amount 7 8 Input State n bytes Exception Domain Name Byte Value Function Code 1 byte 0X02 0
2. 3 0 X 80 Error Code 1 byte 0X1or0x2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code 03 Function Code 03 Start Address H byte 00 Byte Count 02 Start Address L byte 08 Input Register High 00 Read Amount H byte 00 Input Register Low 0A Read Amount L byte 01 Note 1 The unit of the pulse output level width millisecond The unit of the watchdog timer length millisecond Note 2 When power on the highest bit of the watchdog control register is 1 can be done to do determine whether the module is rested or not Write Single Relay Function Code 05 Request Domain Name Byte Value Function Code 1 byte 0x05 Address Setting 2 bytes 0 X 0000 to 0 X FFFF DAM E3013 User s Manual V6 11 eee s X J Z a Content Setting 2 bytes 0x0000 or OxFFOO 0x0000 release relay OxFFO00 engage relay Response Domain Name Byte Value Function Code 1 byte 0x05 Address Setting 2 bytes 0x0000 to OxFFFF Content Setting 2 bytes 0x0000 or OxFFOO Exception Domain Name Byte Value Function Code 1 byte 0x05 0x80 Error Code 1 byte 0x1 or 0x2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code 05 Function Code 05 Set Address H Cbyte 00 Set Address H byte 00 Set Address L byte 05 Set Add
3. DAM E3013 User s Manual 9 Beijing ART Technology Development Co Ltd DAM E3013 User s Manual V6 11 DAM E3013 Module Introduction 16 ch Isolated Digital Input General gt Power Supply unregulated 10 30Vpc Build in watchdogs gt Support 10 100Mbps Ethernet gt Provide default web page or custom built web page gt Power Consumption 2W 24Vpc Digital Input Channels 16 gt Input Level Wet Contact Logic Level 0 1 V max Logic Level 1 4V 30V Dry Contact ground or open circuit Isolated Voltage 3 750V gt Input channel can be used as a 500Hz counter Easy to operate DAM E3013 utility software can help you to select input configuration set the operating parameter for your process control needed Industrial Design DAM E3013 was designed to use in industrial environment It can be installed in standard DIN rail inside the cabinet And it can be powered by unregulated 10 30Vpc to meet the various power supplied source in field It also withstands ambient temperature up to 60 C and resists the effects of vibration and mechanical shock Wiring amp Installation Power supply requirements unregulated 10 Vpc 30 Vpc 4 Vs is a positive and GND is ground The Ethernet interface is connected to a computer switch directly via network cable If the wiring and power is ok then the power indicator should be stop flash and keep on The module initialization is completed The indicator flashes
4. Write Length High byte 00 Read Length Low byte 02 Write Length Low byte 02 Write Data 4 bytes Write Data 4 bytes EEPROM Assignment file 0 define MODULE NET ADDR 0x0000 define MODULE VER ADDR 0x0020 file 1 define NET CONFIG ADDR 0x0000 file 2 to file 7 Note EEPROM is 8kbyte capacity divide to 8 file blocks every block 1kbyte 1 MODULE NET ADDR Restore to factory defaults network configuration parameter Byte 4 4 4 6 Content IP Address Default Gateway Subnet Mask MAC Address 2 MODULE VER ADDR Module Version Information Byte 42byte Content DAM E3012 V6 20 2006 09 01 ID DAME123456 3 NET_CONFIG_ADDR Network configuration parameter call table 1 for structures
5. X 80 Byte Count 1 byte 0X1or0X2 Example Request Response Domain Name Data hex Domain Name Data hex DAM E3013 User s Manual Function Code 02 Function Code 02 Start Address H byte 00 Byte Count 03 Start Address L byte C4 204 h 197 status AC Read Amount H byte 00 212 h 205 status DB Read Amount L byte 16 218 h 213 status 35 Read Holding Register Function Code 03 Note Read the holding register value Data Description 40065 For Ch01 Switch Pulse Count L 16 bits 40066 For Ch01 Switch Pulse Count H 16 bits 40067 For Ch02 Switch Pulse Count L 16 bits 40068 For Ch02 Switch Pulse Count H 16 bits 40069 For Ch03 Switch Pulse Count L 16 bits 40070 For Ch03 Switch Pulse Count H 16 bits 40071 For Ch04 Switch Pulse Count L 16 bits 40072 For Ch04 Switch Pulse Count H 16 bits 40073 For Ch05 Switch Pulse Count L 16 bits 40074 For Ch05 Switch Pulse Count H 16 bits 40075 For Ch06 Switch Pulse Count L 16 bits 40076 For Ch06 Switch Pulse Count H 16 bits 40077 For Ch07 Switch Pulse Count L 16 bits 40078 For Ch07 Switch Pulse Count H 16 bits 40079 For Ch08 Switch Pulse Count L 16 bits 40080 For Ch08 Switch Pulse Count H 16 bits 40081 For Ch09 Switch Pulse Count L 16 bits 40082 For Ch09 Switch Pulse Count H 16 bits 40083 For Ch10 Switch Pulse Count L 16 bits 40084 For Ch10 Swi
6. according to the transmitted data when the module is working DAM E3013 User s Manual V6 11 DAM E3013 Fig l DAM E3013 Drawing DAM E3013 can be installed in standard DIN rail inside the cabinet it also can be installed by stacking mode Fig 3 DAM E3013 stack installation DAM E3013 User s Manual V6 11 Application Wiring Fig 7 Open collector signal input Jumper JP1 shorted 1 pin and 2 pin it is dry contact mode JP1 shorted 2 pin and 3 pin it is wet contact mode DAM E3013 User s Manual V6 11 Default Setting If the module s network configuration is wrong or forget the last modified value the module can be reverted to default settings Steps short circuit the INIT and GND when there is no power power on for 3 seconds power off disconnect INIT and GND The module is reverted to the default settings IP Address 192 168 2 80 2 Subnet Mask 255 255 255 0 3 Default Gateway 192 168 2 1 4 TCP Port 502 5 HTTP Port 80 Operation Interface Click the DAME3000 in ART Data Acquisition Measurement Suite to open the device test system of DAM E3000 Modules x ARI device test system DAN E3000 E File F Device Settinzg S Window W Help I Ip X 9 Remove the module mS DAN E3000 Node Connect the module i Mi Connect module Static link O Dynamic link UDP port oot IP 192 168 2 80 TCP port 502 Module s Jefau
7. lt IP address Wait for connect v be all set fiqure DAM E3013 User s Manual V6 11 Configure parameters ART device test system DAM E3000 File F Device Setting S Window W Help H Box a ie DAM E3000 Node C DAM E3013 192 168 2 80 C gt DAM E3013 16 digital inputs Digital inputs State Counter Describe initial value Input mode 0 DI 0 m 2 3 4 5 6 7 DI Input Describe State Counter Vnus initial value DI 8 Count Clear Input DI 3 Count Clear Input DI 10 DI 11 Input Count Clear Count Clear Di 12 Count Clear DI 13 DI 14 DI 15 DI Input Dblclicking the DAM E3013 192 168 2 80 0 in the system tree of left dialog block to get Network configure info box in this box we can set IP and Device name and TCP port ART device test system DAM E3000 File F Device Winde Help H ls xat DAM E3000 Node Network configure info 43 DAM E3013 192 168 2 80 C DEVIS Current IP New IP Subnet mask 2595 Gateway 192 168 MAC address 10 03 64 34 34 56 TCP port 502 HTTP port 80 UDP port Get IP mode 4000 State Counter initial value Count Count
8. nt High byte 00 Set Amount Low byte 02 Set Amount Low byte 02 Byte count 04 Set Content High byte 00 Set Content Low byte 0A Set Content High byte 01 Set Content Low byte 02 Read File Record Function Code 14 06 Read file record in MODBUS file is considered to be 16 bit array addressing according to address Read file set the start address and read length and change the Start Address and Read Length can traverse the entire file The file does not have a name it has number only You can only read and write one file at one time Request Domain Name Byte Value Function Code 1 byte 0x14 Byte Count 1 byte 0X07 to OX F5 Sub Function Code 1 byte 0X 06 File Number 2 bytes 0x0000 to OXFFFF Record Number 2 bytes 0x0000 to 0x270F Read Length 2 bytes n Sub Function Code 1 byte 0x06 Response Domain Name Byte Value Function Code 1 byte 0X14 Byte Count 1 byte 0x07 to OxF5 V6 11 DAM E3013 User s Manual Sub Function Byte Count byte 0x07 to OxF5 Sub Function Code byte 0x06 Data 2n bytes Exception Domain Name Byte Value Function Code byte 0X 14 0X 80 Error Code byte 0X1or0x2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code 14 Function Code 14 Byte Count 07 Byte Count 06 Sub Functi
9. on Code 06 Respond Count 05 File Number High byte 00 Sub Function Code 06 File Number Low byte 04 Record Data High byte OD IRecord Number High byte 00 Record Date Low byte FE IRecord Number Low byte 01 Record Data High byte 00 Read Length High byte 00 Record Date Low byte 20 Read Length Low byte 02 Write File Record Function Code 15 06 Request Domain Name Byte Value Function Code 1 byte 0X15 Byte Count 1 byte 0X07 to OX F5 Sub Function Code 1 byte 0X 06 File Number 2 bytes 0x0000 to OXFFFF Record Number 2 bytes 0x0000 to 0x270F Read Length 2 bytes n Data 2n bytes Response Domain Name Byte Value Function Code 1 byte 0X15 Byte Count 1 byte 0x07 to OxF5 Sub Function Code 1 byte 0x06 File Number 2 bytes 0x0000 to OxFFFF Record Number 2 bytes 0x0000 to 0x270F Write Length 2 bytes n Data 2n bytes V6 11 DAM E3013 User s Manual V6 11 Exception Domain Name Byte Value Function Code 1 byte 0X 15 0X 80 Error Code byte 0X1or0x2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code 15 Function Code 15 Byte Count 0B Byte Count 0B Sub Function Code 06 Sub Function Code 06 File Number High byte 00 File Number High byte 00 File Number Low byte 04 File Number Low byte 04 Record Number High byte 00 Record Number High byte 00 Record Number Low byte 01 Record Number Low byte 01 Read Length High byte 00
10. ress L byte 05 Set Content H byte FF Set Content H byte FF Set Content L byte 00 Set Content L byte 00 Set Single Holding Register Function Code 06 MODBUS Request Domain Name Byte Value Function Code 1 byte 07 06 Address Setting 2 bytes 07X 0000 to 0 X FFFF Content Setting 2 bytes 0 0000 to 0 X FFFF MODBUS Response Domain Name Byte Value Function Code 1 byte 0X06 Address Setting 2 bytes 07X 0000 to 0 X FFFF Content Setting 2 bytes 0 X 0000 to 0 X FFFF Exception Domain Name Byte Value Function Code 1 byte 0X 0640 X 80 Error Code 1 byte 0X1or0X2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code 06 Function Code 06 Set Address High byte 00 Set Address High byte 00 DAM E3013 User s Manual V6 11 Set Address Low byte 08 Set Address Low byte 08 Set Content High byte 00 Set Content High byte 00 Set Content Low byte 19 Set Content Low byte 19 Set Multiple Relay Function Code OF Request Domain Name Byte Value Function Code 1 byte 0x0F Start Address Setting 2 bytes 0 X 0000 to 0 X FFFF Length Setting 2 bytes 0 X 0000 to 0 X07B0 Byte count 1 byte n Content Setting n bytes Response Domain Name Byte Value Function Code 1 byte 0x0F Start Address Se
11. tch Pulse Count H 16 bits 40085 For Ch11 Switch Pulse Count L 16 bits 40086 For Ch11 Switch Pulse Count H 16 bits 40087 For Ch12 Switch Pulse Count L 16 bits 40088 For Ch12 Switch Pulse Count H 16 bits 40089 For Ch13 Switch Pulse Count L 16 bits 40090 For Ch13 Switch Pulse Count H 16 bits 40091 For Ch14 Switch Pulse Count L 16 bits 40092 For Ch14 Switch Pulse Count H 16 bits 40093 For Ch15 Switch Pulse Count L 16 bits 40094 For Ch15S witch Pulse Count H 16 bits 40095 For Ch16 Switch Pulse Count L 16 bits 40096 For Ch16 Switch Pulse Count H 16 bits Reservation 40130 For Input Latch Enable Register Set bit Enabled Space Disabled V6 11 DAM E3013 User s Manual 40131 For Input Count Enable Register Set bit Enabled Space Disabled 40132 For Input Count Mode Register Set bit Rise Space Fall Reservation 40513 For Watchdog Control Register bitO O disabled 1 enabled bit1 O normal 1 overflow bit2 0 normal 1 reset 40514 For Watchdog Overflow Register Watchdog Overtime Constant 40515 For Watchdog Reset Register OxSSAA Reservation Request Domain Name Byte Value Function Code 1 byte 0X03 Start Address 2 bytes 0X 0000 to 0 X FFFF Read Amount 2 bytes 1 to 125 0X 7D Response Domain Name Byte Value Function Code 1 byte 0X03 Byte Count 1 byte 2n Input Status 2n bytes Exception Domain Name Byte Value Function Code 1 byte 0X 0
12. tting 2 bytes 0 0000 to 0 X FFFF Length Setting 2 bytes 0 X 0000 to 0 X07B0 Exception Domain Name Byte Value Function Code 1 byte 0 X 0F 0 X 80 Error Code 1 byte 0X1or0X2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code OF Function Code OF Set Address High byte 00 Set Address High byte 00 Set Address Low byte 13 Set Address Low byte 13 Set Amount High byte 00 Set Amount High byte 00 Set Amount Low byte 0A Set Amount Low byte 0A Byte count 02 Set Content High byte CD Set Content Low byte 01 Set Multiple Holding Registers Function Code 10 Request Domain Name Byte Value Function Code 1 byte 0x10 Start Address Setting 2 bytes 0 X 0000 to 0 X FFFF Length Setting 2 bytes 0 X 0000 to 0 X 07BO Byte count 1 byte 2n Content Setting 2n bytes DAM E3013 User s Manual Response Domain Name Byte Value Function Code 1 byte 0x10 Start Address Setting 2 bytes 0 X 0000 to 0 X FFFF Length Setting 2 bytes 0X 0000 to 0X 07B0 Exception Domain Name Byte Value Function Code byte 0X 10 0X 80 Error Code byte OXIor0X2 Example Request Response Domain Name Data hex Domain Name Data hex Function Code 10 Function Code 10 Set Address High byte 00 Set Address High byte 00 Set Address Low byte 01 Set Address Low byte 01 Set Amount High byte 00 Set Amou