Home

MB150 User Manual

image

Contents

1. p Cardinal DETECTO Model MB150 Mother Baby Scale User Manual CARDINAL SCALE MFG CO 8535 M212 O1 Rev B PO BOX 151 WEBB CITY MO 64870 03 15 PH 417 673 4631 e FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 e techsupport cardet com TABLE OF CONTENTS INTRODUCTION onanan nananana eeaeee een SPECIFIGAMONS ii a av ede eb Dein BABY TRAY INSTALLATION cuco a ad AGPOWERADAPTOR 23 55 15 34 Renee INSTALLING REPLACING THE IE PONG TIONS ca SEE Eee ernennen en DISPLAY ANNUNCIATORS ooo LEVEILINDIGATOR 3 222232448 82 42 22H 1 a Shee Bir WEIGHT UNIESWITER airport Pope HOW USE BMI FEATURE SETTING THE AUTO OFF TIME leeren ERROR EE 8535 M212 O1 Rev B MB150 FCC COMPLIANCE STATEMENT WARNING This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the int
2. body fat 6 Hold This annunciator will be turned on and Hat d be shown on the display for a few seconds to indicate that the weight from the last weighing operation is being held and the baby child or adult can be removed from the scale This feature is useful if the baby or child is very active 7 gt 0 This annunciator is on the side of the display An arrow will be turned on to indicate the weight is at zero and the scale is ready to use 8 Net annunciator is on the side of the display An arrow will be turned on to show that the weight displayed is net weight Net weight is determined by zeroing the weight of an item from the scale such as protective paper blankets pads or toys This insures that only the baby or adult s weight is displayed kg The kg annunciator is turned on to indicate the weight shown is in kilograms Ib The Ib annunciator is turned on to indicate the weight shown is in pounds LEVEL INDICATOR 9 Level The level indicator is located to the side of the Indicator display If the scale is not level bubble will not be centered adjust mounting feet as required to center bubble and attain a level scale Not Level Level WEIGHT UNIT SWITCH The Weight Unit Switch is located on the lower front right of the scale next to the AC power adapter jack It allows to operator to easily change the weight units from pound to kilograms or kilograms to pounds Mounting Foot AC Power Weight Unit Adapt
3. E BATTERIES The scale use six AA alkaline batteries not included You must first obtain and install batteries before operations can begin Batteries are contained in a battery holder inside the scale Access is via a removable panel on the bottom of the scale 1 Turn the scale over so that the display is 7 facing down 2 Locate the rectangular panel on the bottom of the scale 3 To install or replace the batteries first remove the battery holder cover by pushing in on the tab and lifting it up 4 If installing new batteries proceed to step 5 If replacing the batteries remove all 6 batteries from the battery holder and then proceed to step 5 5 Install the 6 new AA batteries in the battery holder noting the polarity markings located in the battery holder 6 After placing all 6 batteries in the holder replace the battery cover T Turn the scale over display facing up and press the On Off key 8 If the scale turns on the batteries have been installed correctly If not remove the panel and check for one or more improperly positioned batteries 9 The scale is now ready for normal weighing operations 8535 M212 O1 Rev B MB150 5 KEY FUNCTIONS 3 mr qi Z O x al o x BY OSL Ayoede 5 INg PIOH f NY Capaclty j S 20 kg x 0 01 kg Hold 44 Ib x 0 02 Ib B y DETECTO 2 www detecto com Weigh Baby Mode NEVER leave infant ch
4. d press the Tare key The display will change to A UFF Press the Hold or Hold BMI key The display will change to End Press the Tare key The scale will reset The scale is ready for normal weighing operations T IMPORTANT The Auto Off feature ONLY works when the scale is powered by the six AA batteries 8535 M212 O1 Rev B MB150 ERROR MESSAGES Low Battery This message indicates that the battery should be replaced soon If the battery voltage drops too low continued use with a low battery can affect weighing accuracy Remove the old battery and replace with a new battery for operation Over Load The load is over the scale capacity Reduce the load and try again If the trouble still exists please call your scale service representative Over Zero The load is over the limit the scale can zero when powering on Reduce the load and try again If the trouble still exists please call your scale service representative Under Zero The load is under the limit when powering on Power OFF scale and try again If the trouble still exists call your scale service representative 8535 M212 O1 Rev B MB150 00000 mm um
5. er Jack Switch 8535 M212 O1 Rev B MB150 H gt m O p 11 1 2 4 5 6 7 8 9 10 HOW TO USE THE BMI FEATURE Press the Adult mode On Off button Make sure the display is showing DUU If not press the Tare key Press and hold the Hold BMI key The display will momentarily show d and then change to show the last height Note that the BMI annunciator will be turned on and that the height value will be flashing Enter the new height by pressing the key to increase the value or by pressing the key to decrease the value NOTE Press and hold the or key to change the rapidly change the value When the correct value for the height is displayed press the Hold BMI key The display will change to show HUL d and the Hold annunciator will be blinking Have the patient step on to the scale The scale will show the weight and then change to show the BMI value alternating between the weight and BMI value Press Hold BMI button to return the normal weighing mode The patient can now step off the scale SETTING THE AUTO OFF TIME Press either the Adult or the Baby mode On Off key Press and hold the Tare key until the display shows SEE Release the Tare key The display will change to A GFF Press the Tare key The display will change to show the current setting Press the Hold or Hold BMI key to step through the available auto off times When the desired time is displaye
6. erference You may find the booklet How to Identify and Resolve Radio TV Interference Problems prepared by the Federal Communications Commission helpful It is available from the U S Government Printing Office Washington D C 20402 Request stock No 001 000 0031 5 4 PROPER DISPOSAL When this device reaches the end of its useful life it must be properly disposed of It must not be disposed of as unsorted municipal waste Within the European Union this device should be returned to the distributor from where it was purchased for proper disposal This is in accordance with EU Directive 2002 96 EC Within North America the device should be disposed of in accordance with the local laws regarding the disposal of waste electrical and electronic equipment It is everyone s responsibility to help maintain the environment and to reduce the effects of hazardous substances contained in electrical and electronic equipment on human health Please do your part by making certain that this device is properly disposed of The symbol shown to the right indicates that this device must not be disposed of in unsorted municipal waste programs All rights reserved Reproduction or use without expressed written permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Selle
7. ild patient unattended while on the scale Failure to maintain control of infant child or patient at all times while they are on the scale can result in serious injury to infant child or patient 1 On Off Baby Mode 1 Press this key to turn the scale ON 2 With scale on press this key to turn the scale OFF 2 Hold Baby Mode 1 Press this key to hold the weight value while weighing 2 Press this key again to disable the weight hold function Hold BMI Adult Mode 1 Press this key to hold the weight value while weighing 2 Press this key again to disable the weight hold function 3 Press and hold this key for 3 seconds to enter the BMI Body Mass Index mode to calculate body fat 3 Tare Baby and Adult Mode Press this key to zero the scale before starting the weighing operation or to zero off the weight of any item i e protective paper blanket or pad on the scale or in the baby tray 4 On Off Adult Mode 1 Press this key to turn the scale ON 2 With scale on press this key to turn the scale OFF Minus Sign Adult Mode In the Adult mode this key is used with the BMI feature to decrease the height value Plus Sign Adult Mode In the Adult Mode this key is used with the BMI feature to increase the height value 6 8535 M212 O1 Rev B MB150 DISPLAY ANNUNCIATORS 5 BMI This annunciator is turned on when entering the height for the BMI feature and when displaying the calculated
8. ns information on the operation of this scale Please read it before attempting to use the scale and keep it handy for future reference SPECIFICATIONS Adult 33010 x 0 216 150kg x 0 1kg Baby 44lb x 0 02lb 20kg x 0 01kg Function Keys Adult On Off Hold BMI Tare Baby On Off Hold Tare Stabilization Time 1 to 2 Seconds D 32 to 104 F 0 to 40 C Display 1 0 25 mm LCD display with 5 active digits Power 15VDC 300mA AC Power Adapter included or Requirements Six AA alkaline batteries not included Dimensions Tray 23 Lx 11 W x 4 3 4 585 x 280 x 120 mm Scale 13 3 8 L x 13 W x 2 H 340 x 330 x 50 mm 8535 M212 O1 Rev B e MB150 1 BABY TRAY INSTALLATION 1 Install tray from the rear of scale sliding it to the front of scale toward the display Note that arrow on tray should point to front of scale 1 Turn scale upside down to screw tray and platform together properly 2 8535 M212 O1 Rev B MB150 BABY TRAY INSTALLATION CONT 3 Hand tighten the screws to secure the tray to the platform 8535 M212 O1 Rev B MB150 AC POWER ADAPTOR 2 Locate AC Power adaptor jack at front of scale The AC power jack is located on the lower front right of the scale next to the Weight Unit Switch AC Power Weight Unit Adapter Jack Switch 2 Install AC Power Adaptor into jack on front of scale as shown below 4 8535 M212 O1 Rev B MB150 INSTALLING REPLACING TH
9. r assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety in working with tools depend to a great extent upon the individual accuracy skill and caution For this reason the Seller is not able to guarantee the result of any procedure contained herein Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures Persons engaging the procedures do so entirely at their own risk Serial Number PRECAUTIONS Date of Purchase Before using this indicator read this manual pay special attention to all WARNING Purchased From symbols IMPORTANT A ELECTRICAL RETAIN THIS INFORMATION FOR FUTURE USE WARNING 8535 M212 O1 Rev 150 INTRODUCTION The Model MB150 Mother Baby Scale is a dual purpose battery operated scale The scale has two modes of operation One mode will weight and compute the BMI Body Mass Index of an adult up 330lb 150kg The second mode will weight a baby up to 44lb 20kg The scale is also equipped with a removable baby tray to allow weighing small children The scale can be used in a fixed location with the included 15VDC AC Power Adapter or it can be used as a portable scale with six AA batteries not included This manual contai