MORPHEUS M Anaesthesia Unit
Contents
1. All the devices gas feeding supplied by compressed air are automatically supplied by oxygen AGAINST THE SIMULTANEOUS DELIVERY OF AIR AND N20 Selection by membrane key on the flowmeter front panel Setting of MANUAL modality on ventilator MAN with automatic deviation of fresh gas to the manual system of anaesthesia unit valves group or to a TO AND FRO circuit with visual indicator Automatic deactivation of manual ventilation systems directly by ventilator control By apposite membrane key on the front shelf max flow 35 L min e No 3 sockets for distribution system O2 N20 AIR e No 2 sockets for cylinder O2 N20 e No 1 sockets for O2 e No 1 sockets O2 AIR for active scavenger feeding e No 1 fresh gas connector for external use for ex TO AND FRO selectable by apposite membrane key on the front shelf AUX e Socket for recycle of exhaust monitor gas e Connection for anaesthetic gas scavenging optional device active type or passive type 4 8 BREATHING SYSTEM Compact system with automatic connections easy dismountable and autoclavable It allows the ventilation in modality real open circuit semi closed circuit closed circuit at low flows The system also allows the spontaneous and manual ventilation in case of anaesthesia unit breakdown or machine off Top special CO2 absorber canister of 1 Kg with rapid connection this allows canister replacement also during interventions the canist
2. Te Fi Fe Cs Ri Ventilation Curves CURVES Pressure Flow Volume LOOPs Volume Pressure and Flow Volume Measurement RANGE automatic Trend Scale and 72 hours trend period setting Foreseen Trends PAW PEEP VTe ExpMV Rate Events Memory storage up to 100 events per machine including the alarms GAS ANALYSIS Optional Function Gas analysis Integrated software for analysis of CO2 O2 N20 AG automatic identification MAC Mainstream device e IRMA AX CO2 N20 primary and secondary agents HAL ISO ENF SEV DES e IRMA CO2 CO2 Sidestream device e ISA AX CO2 N20 Agents e ISA CO CO2 e ISA OR CO2 N20 Agents O2 Technical characteristics Consult the relevant technical data sheets for mainstream and sidestream modules Morpheus _M_te_rev3 7 8 ELECTRIC POWER SUPPLY Electric power supply 100 240Vac 45 60Hz Maximum power 120 Watt Back up battery 12Vdc 3 Ah pb battery which guarantees an autonomy of around 120 minutes Charging time Around 10 hours CONFORMITY TO DIRECTIVES Class and type according with IEC 601 1 Class Type B Class according with 93 42 EEC Dir ve Class IIb IEC 601 1 IEC 601 1 1 IEC 601 1 2 IEC 601 1 4 EN 1281 1 UNI EN 740 UNI EN ISO 9703 3 EN 4135 93 42 EEC Dir ve ACCESSORIES Standard accessories User s Manual O2 supply hose N20 supply hose Air supply hose e O2 cy
3. MORPHEUS M Anaesthesia Unit code OM3 S5 rev 3 dated 09 01 2013 INTENDED USE The MORPHEUS M is an anaesthesia unit and it can be used on adult children and newborn patients The MORPHEUS M is suitable for administration of Oxygen Air Nitrous Oxide Halothane Enflurane Isoflurane Sevoflurane Desflurane mixtures GENERAL DESCRIPTION The MORPHEUS M anaesthesia unit is completed with Morpheus_M_te_rev3 mechanic gas mixing system electronic lung ventilator with 12 TFT colour display valves group open semi closed closed heated with soda lime absorber of 1 Kg capacity SIARETEX rapid connection device Selectatec compatible for 2 vaporizers gas supply group gas analysis optional function TECHNICAL DATA Structure Wheels Drawer Cylinder support Support for 2 vaporizers Auxiliary power supply outlets Work shelf lighting Dimensions Weight Environmental conditions GAS MIXING SYSTEM owe ees ane E BS205 LOLE 1 Siel sie ae Soe lt _ nie a 2 pe G a gt No 2 FRY J Morpheus_M_te_rev3 Light aluminium alloy and plastic moulds Pivoting antistatic wheels diameter 100 mm 2 with brakes No 3 full extension drawers No 2 vertical cylinders supports on the back side for cylinders up to 10 litres capacity and round rubber pads On horizontal guide SIARETEX rapid connection device Selectatec compatible for 2 v
4. aporizers No 1 SCHUKO 220 Vac outlet max 6 A 12Vdc by led 71 x 77 x 138 L x P x H cm without monitor 72 kg without accessories e Temperature from 10 to 40 C e Relative humidity from 10 to 90 non condensing It has the function to regulate the capacity and the concentration of gas mixture Air O2 N20 as well as to deliver it to the anaesthetic gas vaporizer It allows to select the mixture to be delivered Air O2 or N20 O2 and the O2 enrichment for delivered mixture in case of emergency The anaesthesia module includes a device which guarantees a minimum concentration of 25 oxygen in all conditions MIX LIFE device The three pressure gauges on the front panel allow the continuous control of medical gas feeding pressure coming from the gas pipelines system 2 8 Oxygen rotameter Nitrous oxide rotameter Air rotameter Low flows oxygen rotameter Low flow nitrous oxide rotameter Medical gas supply Gauges Alarms Morpheus_M_te_rev3 Scale 0 1 15 L min Resolution 0 1 L min up to 1 L min and 1 L min up to 15 L min Accuracy 10 of read value or 1 of end scale whichever is the worse case Scale 0 2 12 L min Resolution 0 1 L min up to 1 L min and 0 5 L min up to 12 L min Accuracy 10 of read value or 1 of end scale whichever is the worse case Scale 0 1 15 L min Resolution 0 1 L min up to 1 L min and 1 L min up to 15 L min Accuracy 10 of read valu
5. e or 1 of end scale whichever is the worse case Scale 0 1 1 L min Resolution 0 05 L min Accuracy 10 of read value or 1 of end scale whichever is the worse case Scale 0 1 1 L min Resolution 0 05 L min Accuracy 10 of read value or 1 of end scale whichever is the worse case OXYGEN e Pressure included between 280 kPa and 600 kPa 2 8 6 bar e Max required flow 90 L min NITROUS OXIDE e Pressure included between 280 kPa and 600 kPa 2 8 6 bar e Max required flow 15 L min MEDICAL COMPRESSED AIR e Pressure included between 280 kPa and 600 kPa 2 8 6 bar e Max required flow 90 L min No 3 on front panel O2 N20 AIR scale 0 6 bar Lack or low oxygen pressure with consequent cut off of nitrous oxide delivery 3 8 Safety devices Control for activation of exit of fresh gas for manual ventilations O2 emergency by pass IN gas sockets on gas supply group OUT gas sockets on gas supply group Other Morpheus_M_te_rev3 AGAINST THE ADMINISTRATION OF HYPOXIC MIXTURES MIX LIFE it always guarantees a minimum concentration of 25 oxygen on mixtures which includes nitrous oxide IN CASE OF LACK OR LOW OXYGEN PRESSURE CUT OFF audible alarm with immediate cut off of nitrous oxide delivery AGAINST OVERPRESSURE IN FLOWMETER BOx Safety valve calibrated at 0 8 bar for the protection of the glass rotameters IN CASE OF LACK OR COMPRESSED AIR LOW PRESSURE
6. er is autoclavable and reusable The recycling system is a selective type hence the soda lime and fresh gas consumption are reduced to the minimum The heated valves group reduces the condensation and heats the fresh gas The transition from one ventilation modality to another is completely controlled by the ventilator without any user s action on valves group LUNG VENTILATOR VC VAC O 20 40 60 80 11 15 1 2 99 02 09 11 09 25 01 User s interface 12 TFT high resolution colour display with membrane keyboard and encoder Control modality Electronic by microprocessor Dead space compensation system Automatic Flow generation Electronic system Gas feeding Medical compressed air or Oxygen with pressure included between 280 kPa and 600 kPa 2 8 6 bar Option Turbine for gas feeding independent from gas pipelines system Morpheus_M_te_rev3 5 8 Autotest Primary test at anaesthesia unit s start up a control test of medical gas supply circuit losses INSP and EXP flow sensors operation pressure sensor patient circuit losses back up battery state oxygen cell integrity of audible alarm is automatically performed This test takes around 15 seconds Subtest the unit for anaesthesia has a subtest which is activated by the user in the ventilator menu This subtest permits to verify the dead space and losses or to perform the oxygen cell calibration Ventila
7. linder supply hose N20 cylinder supply hose Top Special CO2 absorber canisters 2 of 1 kg O2 cell Adult silicone patient circuit Adult Mapleson C adult patient circuit Manual ventilation KIT SHUKO VDE electric power supply cable Other optional accessories See current export price list SIARE applies the UNI EN ISO 13485 2004 Quality System and 93 42 EEC Dir ve SIARE ENGINEERING INTERNATIONAL GROUP s r l Via Pastore 18 40056 Crespellano Bologna ITALY Tel 39 051 969802 Fax 39 051 969366 E mail mail siare it http www siare it Morpheus_M_te_rev3 8 8
8. tion modalities Ventilation modalities optional APCV PCV APCV TV PSV APNOEA BACK UP VC VAC SIMV PS volumetric SPONT MANUAL Integrated NEONATAL ventilation mode VC VAC BABY CPAP SIMV PS by pressure BILEVEL S ST Breathing rate From 5 to 120 bpm step 1 bpm E Ratio Inspiratory time Inspiratory pause SIMV rate Tidal volume Minute volume PEEP 1 1 1 1 5 1 2 1 3 2 1 3 1 From 0 2 to 5 sec From 0 to 60 of inspiratory time From NO 1 to 119 bpm From 5 to 1500 ml lt 50ml step 1ml 50 100mlI step 5ml gt 100ml step 10ml From 1 to 30 liters OFF 3 30 cmH20 step 1 cmH20 Inspiratory flow From 1 to 80 L min Minimum resolution 1 Oximeter Automatic calibration procedure Bronchomanometer 20 80 cmH20 Flow trigger From OFF 1 to 15 L min step 1 L min Pressure trigger From 1 to 9 cmH20 under the PEEP level Safety Electronic and mechanical limit of airways pressure Self diagnosis system Morpheus_M_te_rev3 6 8 Alarms e Low High airways Pressure Low High Breathing Rate Low High O2 Concentration Low High Tidal Volume Electric Power Supply e Apnoea Low Battery Low Gas Supply Disconnected Patient Circuit Can Bus Failure Flow sensor Internal to the valves group by magnetic perturbance reusable Measured parameters e PAW PEEP Rate I E FiO2 Vte ExoMV e MAP Pplateau Tpause Ti
Download Pdf Manuals
Related Search
Related Contents
Serie 6,Unidades de piso para montajes verticales TABLES DES MATIERES - WEBER Assemblages automatiques Téléchargez la plaquette d`information disponible User manual JVC LT-42E478 42" Black LCD TV Índice Sony Ericsson K800i MANUAL DE MANTENIMIENTO PDFカタログ - 株式会社トキワ Guida dell`utente della fotocamera Copyright © All rights reserved.