Home

IPU-1025

image

Contents

1. IPU 1025 jo 1 DESCRIPTION C w ude RRE DEVICE CALL ON OK FAULT IN OUT CONFIG NET USB Q OQO OO 00 uH ACTIVITY C1 ENGINEERED AND MADE IN E U X X INPUT 1 E mama Jamm AUDIO LINK LAN 24VDC C1 Mm srk C1 me The public address system for IP networks of UNION DESARROLLOS ELECTRONICOS allows the creation of conventional PA and security systems allowing us to interconnect with IP devices following SIP standard Union Desarrollos Electronicos Audio offers the IPU 360 SIP server that will centralize and coordinate all communication of IP paging elements ensuring maximum functionality of all of them with minimal risk The IPU 1025 has included many functions within the same device decoder and audio manager With these functions allow the user to Connect to loudspeakers horns or trumpets directly through the integration of a class D amplifier with a maximum power of 25W This amplifier has a low impedance output allows direct connection to PA speakers Connect the decoder within an IP network Connect an audio source Connect a microphone with or without phantom power for simple messaging to the IP network The IPU 1025 decoder becomes the key element to ensure compatibility with all loudspeakers and horns trumpets on the PA portfolio of UNION DESARROLLOS ELECTRONICOS so that you can use to adapt older installations today Besides concentrating on just one set o
2. Installation Configuration Use IPU 1025 ROMI 610 440A 29 29
3. IPU 1025 AUDIO IP DECODER with 25W Class D AMPLIFIER Installation Configuration Use FRONT e ode LIES gt DEVICE CALL OK FAULT IN OUT CONFIG NET US OO OO 60 umm C a E nang neur R C a AUDIO LINK LAN om LTL Q Ea srk d EL GM N D EX 1 DESCRIPTION eee 2 TECHNICAL DATA _ 4 1 Front view 4 2 Rear view ee eae 5 DEVICE CONFIGURATION WEBSERVER 5 1 Home page HOME NENNEN 5 2 SIP Configuration SIP EN TU 5 3 Extension SIP Configuration EXTENSIONS s VS 5 3 1 Erasing amp editing 10 5 3 2 P A zones edit page 16 5 4 Device configuration DEVICE 22 5 5 Network configuration LAN NETWORK 25 5 6 Time configuration TIME ZI 5 7 Date configuration DATE RENNES 9 8 Password configuration device e PASSWORD PEERS 5 9 Reset to factory default RESET TO FACTORY o 29 5 10 Remote Reboot REBOOT 2g co CON OO OO BW N OTN Le BI ade yO hom ot R8 doo Oh UD oa WCHL MIC A CHCMMUCECOMe RIC CIN ROM CCAM WWww udeaudio com Barcelona Madrid PUBLIC ADDRESS gt Avda BARCELONA 24 Tel 34 93 477 28 54 C LUIS 88 35 planta Tel 34 913116076 ISE Nea 08970 SANT JOAN DESP Fax 34 93 261 17 52 28031 MADRID Fax 34 91 450 19 97 uge BARCELONA ESPA A ude udeaudio com ESPA A centro udeaudio com Al 610 440A 1 29
4. Use IPU 1025 NI UGC VALUES PIC32 CPU Microchip powered 10 100Mbit Full Half duplex Autonegociaci n AutoMDI MDI X Compatible con PoE IEE802 3af LINK and ACTIVITY leds included 1 RJ 45 socket type 8 pins IP protocols supported IPVA IPV6 not supported DHCP Auto Manual TCP IP UDP RIP SIP HTTP AnnouncelP The IPU 100 can only process non fragmented packets Dedicated port to the connection with the IP Paging Desk IPU 100P that includes Digital Control Bus RS485 115200bps 8bits No Parity 1 stop bit No flow Control Balanced Audio Output 0dB 0 775mVrms 600Q Balanced Audio Input 0dB 0 775mVrms 10KQ Dedicated port to connect to analog input audio devices Differential Microphone 2mVrms 600Q Phantom 12V LINE IN 300mVrms 10KQ connection to auxiliary Background Music devices Activation through REMOTE IN Close Contact or VOX function Dedicated port to the connection of loudspeakers horns or trumpets at low impedance Audio Output 25W 8Q THD lt 10 Activation of REMOTE OUT Close Contact INCOMING call on live Maximum Load capability 0 5A at 24Vdc Open Contact no INCOMING call received USB 2 0 Type A Power ON LAN Activity NET ACTIVITY CONFIG mode OUTCOMING call CALL OUT INCOMING call CALL IN Device properly register on SIP server DEVICE OK Failure on Device DEVICE FAULT 3V Lithium Battery CR2025 type Not rech
5. there is no other extension to configure and configuration must be uploaded Click on button Send data Button 2 configuration has been saved and screen shows the new button A 9 00 00 ude IPU 100P Paging Desk 1001 002 Zone 1 Main room Installation Configuration Use IPU 1025 ROWY 610 440A 20 29 IPU 1025 ja CAUTION Incorrect settings may cause IPUTDOP failure Please be sure you press Exit for closing properly the edit session If you have doubts about parameters please contact with the Network Admin BUTTON 3 EDITION Group Definition Group ID FOO of 250 eb Group Hame Zona alta Remove GROUP xtension Assiqnament Extension ID z001 af 250 1003 1004 1010 000 Gaas Jc BUTTON 3 EDITION The parameters to configure for button 3 1 Button 3 label 2 Extension to call 003 equal to 1003 3 Confirm extension with Add EXTENSION 4 Extension 1003 appears in the extension box 2B Type the second extension to call in button 3 this is extension 004 equal to 1004 3B Confirm extension with Add EXTENSION 4B Extension 1004 appears in the extension box 2C Type the second extension to call in button 3 this is extension 010 equal to 1010 3C Confirm extension with Add EXTENSION 4C Extension 1010 appears in the extension box 5 In button number three has three extensions to call 1003 1004 and 1010 there is no other extension to configure and configuration
6. Address by Factory default Attention If the IP assignment mode is Static or FIXED selected this IP address should be provided by the Network Administrator Please contact with him before changing this setting as it can affect the proper functioning of the IP network SubNet Mask format XXX XXX XXX XXX Defines the subnet mask assigned to your fixed IP These data should be provided by the Network Administrator Example SubNet Mask 255 255 255 000 Subnet Mask by Factory default GateWay format XXX XXX XXX XXX Defines the address of the device on the local area network that allows you to connect to other computers and usually assigned IP address when the system is configured in DHCP mode or automatic Example GateWay 192 168 000 001 Gateway IP by Factory default Primary DNS format XXX XXX XXX XXX Defines the address of the device on the local area network or external that will allow you to connect to other computers in the world through URLs This address can be not necessary for normal use of your device then assign it a null address 000 000 000 000 or simply leaves it blank Example of valid Alternative DNS Primary DNS IP 192 168 000 001 Primary DNS IP by Factory default Alternative DNS o Secondary format XXX XXX XXX XXxX Defines the address of the device on the local area network or external that will allow you to connect to other computers in the world through URLs in case the Primary DNS does not w
7. Mode Output Volume thaput Bass Treble D dB of 20 Hz i 000 dB ad 8 KHI DESKMIC HE Volume 127 EXT MIC Mi Volume Time to Expire Register seconds ALIVE Mowe 0PU 100P or IP1I 162 5P OLY ic Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despi Barcelona Tel 34 93477 28 54 Fax 34 93 261 17 52 e Summary of Configuration Parameters In this area you can check quickly what are the basic parameters of the device s Parameters are displayed relative to the software Application version the LAN settings IP MAC DNS the connection parameters to the SIP server SIP Server IP data ports SIP Extension number SIP authentication password volume values assigned to the audio inputs and outputs Status Monitor In this area you can see three zones e LEDs status It shows in real time the status on off flashing of all indicators present on the front panel e Activation signal status Shows the state of the activation signals of different basic functions such as VOX activated MIC activated etc e Sensor level status It shows the voltage measurement of the sensors included on the device 24V Adaptor 24V Backup Battery VOX signal level detected Microphone supply o Area 5 Time and Date Installation Configuration Use IPU 1025 OWM 610 4404 9 29 IPU 1025 ga 5 2 SIP CONFIGURATION SIP The configuration page allows you to configure SIP parameters to ensur
8. Tel 34 83477 28 54 Fax 34 93 261 17 52 Installation Configuration Use IPU 1025 Rea 610 440A 14 29 IPU 1025 Ja 5 DEVICE CONFIGURATION WEBSERVER 5 3 1 ERASING amp EDITING Extensions Extension main page In the Extension page click on NEW DialPLAN With this selection the IPU 100P begin the process to erase all the information in memory The data structure will be the factory profile Caution The erasing process is irreversible in case of error the memory information cannot be recovered 00 30 15 FRI 17 05 7013 UNION DESARROLLOS ELECTRONICOS Changing the Dialplan This page is useful for changing the dialplan extensions and groups required by the IPLTOOP ap CAUTION The dialplan configuration setup requires a long time to perform it but can be modified partially in different sessions from the WwebServer EDIT MODE Please cancel this action if you can not finish it in the same session For this operation irs mandatory to have connected an IPU 100P before selecting a NEW Dial Plan or Edit current one Starting NEW DialPlan requires up to 45 minutes to prepare the filesystem but depends of data to clear could be less Please be patient during this process Thanks a Dewite o W you have doubts please dont hesitate to contact wih the Network Admin Network SIP Do you want to start a NEW Dialplan updating session or enter in EDIT made If you have doubts please CA
9. input and one output that allow the exchange of audio between the IP Paging Desk Controller and the IPU 1025 encoder decoder We recommend using UTP wiring to connect both devices The IPU 100P IP Paging Desk can be powered via the AUDIO LINK when you are less than 50 meters of the IPU 100 BR UE STRAIGHT CABLE 568B Sonn WEE BUE ITE ELTE TE GREENE n 3 ene ORANGE WHITE 7 EIA TIA 568B EIA TIA 568B 1 ORANGE WHITE INPUT This block of terminals allows us connecting an external audio input be an auxiliary LINE source or an external microphone with the possibility to power it with 12V of phantom power activated from the Webserver iid ER Activation when there is a microphone or background music source can be done with Activation by closing remote input to the ground terminal Activation by detecting audio signal modulation MIC LINE IN BS MIC LINE IN OV GND REMOTE IN TL LINE OUT SPK This euroblock connector is the audio output from the incoming call via IP networks enabling SPK ma m m p S LINE OUT connection of IPU 1025 in low impedance to a speaker horn trumpet or a set of these While the OV GND incoming call is active the remote control output will remain active closed contact REMOTE IN TL Caution Avoid to connect on the input or line block terminals direct connections to the ground including MIC LINE and TL In case the line TL it is used a power supply do not ref
10. label and the different extensions that will call 00 32 47 FRI 17 05 2013 UNION DESARROLLOS ELECTRONICOS CAUTIOM Incarrect settings may cause IPLIODF failure Please he sure you press Esn for closing properly the edit session If you have doubts about parameters please contact with the Network Admin Group Definition Group BD BLOT of 250 Groupes zre Device Extension Assiqnament ETT Extension I E01 of 250 Diaz Tn KST Add EXTENSION NOTE Vislidi eom 1001 to 1250 Password Reboot Las ea Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despi Barcelona Tel 34 03 477 28 54 Fax 34 93261 17 52 Installation Configuration Use IPU 1025 ROW 610 440A 16 29 IPU 1025 cda 5 DEVICE CONFIGURATION WEBSERVER EDIT ZONE PAGE Group Definition Gr oup ID 001 of 250 3 Group Hame Zona 1 Remove GROUP Extension Assignament Extension ID 001 of 250 5 Dialz 1XXX Add EXTENSION NOTE Valid from 1001 to 1250 E IPU 100P buttons navigator Exist 4 different icons to navigate First Drev Tu mmm along all the buttons of the touchscreen First Next _ Move one button back Last button First button Move next button ZZ Button edition indicator Group ID of 250 Button Top number Example of maxim number to edit E Group nameEach IPU 100P button can show a label to give more information about
11. must be between 3000 and 3999 Example Default Call streaming 3400 SIP Receiver Priority Level Max 01 min 99 Not use SIP Streaming Priority Level Max 01 min 99 If the UDE PAsystem is active and the IPU 1025 in codifier mode a priority can be applied and the IPU 360 will manage This priority should be between 01 max priority in consequence will cut other emitters and 99 lowest priority These characteristics give tools to program de PA system over IP If you need more information of the max number of priorities consult the IPU 360 datasheet The SIP Streaming Priority Level must be configured with audio sources like MP3 players or Microphones like PZ 40 for Music on hold calls Itis a different priority from the IPU 100P SIP Paging Desk Priority that only concerns desk control microphones IPU 100P SIP Paging Desk Priority Level Max 01 min 99 These characteristics give tools to program de PA system over IP if the IPU 1025 is linked with an IPU 100P desk control a priority desk can be applied This priority must be between 01 max priority in consequence will cut other desk control and 99 lowest priority These characteristics give tools to program de PA system over IP If you need more information of the max number of priorities consult the IPU 360 datasheet The IPU 100P SIP Paging Desk Priority Level is setting for IPU 100 linked with IPU 100P is different from the SIP Streaming Priority for audio sources o
12. of PA zones will be a totally broadcast message for all the zones configured in the IPU 360 SIP server Zones extensions 1002 Zone extension Description label BEES Description label To edit the IPU 100P zones exists 2 ways 1 Erasing the whole desk control memory 2 Editing zones keeping the zones configuration 00 30 15 PE T FRI 17 05 2013 n E pe ag EEUU MM Meu UI Cc UNION DESARROLLOS ELECTRONICOS Groups and Dialplan Configuration Menu IPU 100P Changing the Dialplan This page is useful for changing the dialplan extensions and groups required by the IPLHODP amp O CAUTION The dialplan configuration setup requires a long time to perform it but can be modified partially in diferent sessions from Ihe WeabServer EDIT MODE Please cancel this action if you can not finish it m the same session For this operation i s mandatory to have connected an IPU TO0P before selecting a NEW Dial Plan or Edit current one Extension e Starting a NEW DialPlan requires up to 45 minutes to prepare the filesystem but depends of data to clear could be less Please be patient during this process Thanks you have doubts please dont hesitate to contact with the Network Admin eric Network Do you want to start NEW Dialplan updating session or enter m EDIT mode If you have doubts please CANCEL ResettoFactory Copynght 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despl Barcelona
13. software from the USB terminal Installation Configuration Use IPU 1025 OWY 610 440A 6 29 IPU 1025 Ja 4 DESCRIPTION OF CONNECTIONS o pang ves JAE o AUDIO LINK LAN Ra 24VDC Q Mm srk X a ae ae 9 DCIN This connector allows us to power the device using a 24Vdc external power supply model IPW 25 These include that of the 2 powering methods available on the IPU 1025 the power input with the IPW 25 AC adapter DC IN is the highest priority input and disables the battery backup input which only supply power if the voltage delivered in the DC IN terminal is absent or is lower PRIORIDAD than 18Vdc PRIORIDAD Alimentaci n Alimentaci n 24V est ndard emergencia 24 VDC The terminal allows IPU 1025 connection to a battery backup system to preventthe system fails during a primary power failure IPW 25 LAN The LAN port allows the connection of the IPU 1025 to the IP network It supports automatically low speed networks 10 BASET 10Mbits and improved speed networks 100 Base TX 100Mbits The left indicator reports data activity on the LAN ACTIVITY while on the right it is properly linked to the LAN LINK I Attention The IPU 1025 can only process non fragmented packets AUDIO LINK This connector allows connection of an PU 100P or allows the expansion and control of external devices through the digital bus also has a balanced analog audio
14. the zone to call in that button the label can have a maximum of 20 alphanumeric letters 0123456789 0123456789 FY Extension configuration in a button Extensions ID of Extension Top number FJ Extension configuration To enter the extensions in a button the configuration must be done one by one extension that is enter one extension send the information and successively for all the extension to be in one button Furthermore the decoders extension are in the Rank between 1000 and 1999 To make it more simple is precise to type the last 3 digits of the extension the first digit number 1 is automatically processed D Extension cache The extension are saved in a cache memory waiting to be sent to the IPU 100P the Rank of the extensions is between 1000 and 1999 For example when extension 1300 typing 300 and clicking Add EXTENSION the new number appears in the extension Validate When all extensions labels and buttons are ready click on Send data This action must be done every time one button is edited Installation Configuration Use IPU 1025 OWM 610 440A 17 29 IPU 1025 ade 5 DEVICE CONFIGURATION WEBSERVER Button configuration example This example contains the configuration of 3 IPU 100P buttons with this characteristics BOTTON 1 Button name Zone 1 Extension to call 1001 Button 1 edition Number of extension to call by the button Type new label Click on Send dat
15. Extension icon in the left menu and click EDIT DialPlan If you did the erase memory process you will be redirected to the PA zones edit page of the IPU 100P 00 30 15 FRI 1 05 7013 UNION DESARROLLOS ELECTRONICOS Changing the Dialplan This page is useful for changing the dialplan extensions and groups required by the IPUTOOP CAUTION The dialplan configuration setup requires a long time to perform it but can be modified partially in different sessions from the VebSereer EDIT MODE Please cancel this action if you can not finish it in the same session For this operation irs mandatory to have connected an IPU 100P before selecting a NEW Dial Plan or Edit current one Starting 4 NEW DialPlan requires up to 45 minutes to prepare the filesystem but depends of data to clear could be less Please be patient during this process Thanks haves W you have doubts please dont hesitate to contact wih the Network Admin Hate rk Do you want to start a NEW Dialplan updating session or enter in EDIT made If you have doubts please CANCEL Time Dale Reset to Factory Reboot Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despi Barcelona Tel 34 83 477 28 54 Fax 34 93261 17 52 The zone edit page has two main areas one is the general navigation and edition of the buttons that already exist in the desk control IPU 100P and another area allows editing one specific button adding the
16. L ResettoFactory VoIP Codec 6 722 ADPCM bas 16KHz Audio Bl Type Phantom Mode LINE Type OFF BEEPER Mode VOX Mode Threshold ON OFF 3 40 PreVox Time PostV x Time seconda pos 010 TMI GUT Actization bonde Cisl ANY incoming call Output Volume 128 Dpt Bass Trebles D dB of 20 Hz i 00 dB al B KHI DESK MIC HE Volume 127 EXT MIC M Volume 050 Time to Expire Register 86c0nds E 3500 ALIVE Mode 1PU 100P or IP 167 5P ONLY ic Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despi Barcelona Tel 34 03477 28 54 Fax 34 93 261 17 52 NOTE UNION DESARROLLOS ELECTRONICOS reserves the right to modify all or part of WEB server design in order to offer a better product to their customers which is why we may appear different from pictures provided in this document and results that you can get the product you have purchased If you have any doubts consult the technical department of UDE SIE Menu This area specifies the different web pages with configuration parameters 2 List of available Menus This area displays the menu selection icons that the user can select for your device configuration When the user selects a different menu to the HOME or Main will be asked to enter a password If the password is right and match any of the previously stored will then open the desired menu if not the access will be denied F dente gcp requenda l Q http 172 23 51 13 esta sob
17. NCEL CR GE NEW DesiPlan EDIT Dolan CANCEL Reset ta Factory Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avia Barcelona 24 Sant Joan Despi Barcelona Tel 34 03 477 28 54 Fax 34 832681 17 52 Erasing process page Depending on the amount of information saved on memory the erasing process can spend from 10 seconds to 44 minutes to erase all data The IPU 100P screen while the erase process is execute will keep out of work for any paging call Also a deleting data message will be printed to give user information Preparing Hey Diuplan me n 142 peli Yad Cee halitu YO ip cre nis Pha be pri 13 11508 Dale be ATTENTESM E rene TRE dirigas dalur neqoe birg Iras Es purto d un ES 24 eer 13 priS Sab Vari spier renders 0 363 Duae the hris Dian could be ioa Ele 586 b pihy Li d ec Par dafi eee hel leai ga Lan i endi 1 ta K h ih ila 18 dris EDT p r n CANCEL Hi ahuda po hera z s Zone edit page When the erase process has finished the webpage will be redirected to the zone edit webpage also the touch screen of the IPU 100P will Work Installation Configuration Use IPU 1025 ROAY 610 440A 15 29 IPU 1025 9 3 2 P A ZONES EDIT PAGE Extensions Each IPU 100 can be linked only with one IPU 100P The connection between the codifier and the desk control must be done point to point and other configuration must be rejected To access the edit zone page click on
18. Reboot icon on the left menu and confirm clicking on REBOOT icon 18 11 46 TUE 11 02 2014 UNION DESARROLLOS ELECTRONICOS Reboot the device Thes page is useful for reset the device allowing the operator to samulate a power ON sequence CAUTION Tha acbon requees an evtialu aeon tme please wad unti device complete i Please refresh your WEB Explorer to get access agam H you have doubts please don hes amp ae to contact with the Network Admn Do you wart te REBOOT me board If you have doubts please CANCEL mEPoon cncm Copynght 2013 UNION DESARROLLOS ELECTRONICOS Avda Darcelena 24 Sart Joan Drap Barcelona Tel 24 93 477 28 54 Fan 3403 2601 17 52 m UO DESARROLLOS ELECTROMCOS Reboot In Progress Tour seting were aacocsstully saree an fhe board e nw rebxac ong be configure dell meth Lhe rm sete B Your boand i riw Loeabmd at bie P1100 Reconnection Instructions 1 ee a te a 1 rk Piima re a caa E CalPak R N fa Ten hg Ca ieee 00 ed awh Deer ae KRK LNR ed et ee os Ren ee ee PTR a Vs pra try tan P dol reus 7 lrs pone eg Si hind de wa NT cire nn Pad pou 9 15609 aeui jav enfer EE URE HOT omia ar famen HS de Pra Fea E ee unu nad 1 p raura ep Sm alr v mars 3 JEN pui ears Pa 55 str Baz a Ta Lda Lir p mu company rn e 4 E gt K 4 al Coed 3014 UNI DESARBOLLOS ELECTIEONICOS Arda Barcelona 24 Jart Joan Deipi farceiona Te 234 B3 477 28 54 Fax vH 3201 17 54
19. U 1025 device that registers with the IPU 360 server correctly and received the authorization to use the IP installation will remain with the DEVICE OK indicator on The correct register requires a configuration made Mon our IPU 100 and another on the IP server This action must be performed only by authorized service personnel Remember If you experience problems with the DEVICE OK so if it ever turns off sporadically then it is recommended to contact with your local network administrator LAN LED DEVICE FAULT The public address system for IP networks according to the SIP standard requires signaling data in order to establish a secure and reliable communication executed in the initialization of a device to connect to the LAN Local Area Network or periodically to refresh the status of the IPU 360 server The IPU 1025 automatically executes a registration attempt to the server configured in its settings and every time you restore the power will also run the connection attempt During the process the device remains without registration with the IPU 360 server the DEVICE FAULT LED is RED indicating that there is a connection problem with the server so the device is not operating temporarily Along with the lighting there is a error beep signal that emits periodic tones indicating the inoperability of the encoder decoder beep sound can be disabled from the Webserver Connector USB The device allows the updating of internal management
20. U 1025 model is the element that allows the decoding of audio sent digitally to a conventional audio signal to be amplified conveniently and connected directly to speakers horns or trumpets The IP Paging Desk IPU 100P with color touch screen where the operator can select the zones where the message must be activated once you press and hold the button of PTT Talk In addition the SIP server IPU 360 which acts as intermediary between all IP devices connected to the LAN working As can be seen our IPU 1025 devices can connect to the wide range of speakers horns and trumpets of UNION DESARROLLOS ELECTRONICOS IPU 100P Device _CALL_ l OK FAI N OUT NET USB N J IPU 1025 ude GE DEVICE CALL o OO OO 60 mm aen im IPU 1025 m m m m IPU 1 00 ade EXE l S K T j J oo oo e o m P 3 7 N J Lk nne IPU 1025 LI T T TAT IPU 360 Installation Configuration Use IPU 1025 ROWY 610 440A 4 29 IPU 1025 je UOUE 4 DESCRIPTION OF CONNECTIONS f 4 1 Front view B 1 R ude Zu gt DEVICE CALL ON OK FAULT IN OUT CONFIG NET USB O 00 OO OO ACTIVITY a co 8 LED ON This indicator shows that the equipment is properly powered and that the main application is running M LED NET ACTIVITY This indicator shows the data activity when is connected to an Ethernet LAN When you receive IP pack
21. a rez 002 003 Main room Yard 002 Main room BOTTON 2 Button name Main room Extension to call 1002 1400 Button 2 edition Number of extension to call by the button Type new label Click on Send data IPU 100P Paging Desk BOTTON3 Button name Yard Extension to call 1003 1004 1010 Button 3 edition Number of extension to call by the button Type new label Click on Send data Cd Foire ome peters may cave PUNON dad oboe pas arreriari pleada corda weh the Metesth Aron 0 Ld 5 D 9 8 i a z l like anspik af wiki prm 3DDS ia 1253 Installation Configuration Use IPU 1025 ZONE EDIT PAGE Without any data inside the system the webpage should look Edition of button 1 First extension to configure inside the button 1 RGW 610 440A 18 29 IPU 1025 Ja 5 DEVICE CONFIGURATION WEBSERVER EXTENSION Configuration Memu 00000 BUTTON 1 EDITION CAUTION Incorrect settings may cause IPUTDOP failure Please be sure you press Exit for closing properly the edit session If you have doubts about parameters please contact with the Network Admin Group Definition Group ID s001 of 250 eb Group Hame Zona 1 Remove GROUP xtension Assiqnament Extension ID FOO of 250 e Dial 1X XX 001 Add EXTENSION Ms 3 id from 1001 to 1250 1001 Q Cm ces BOTTON 1 EDITION The parameters to configure for button 1 1 Button 1
22. activated communication is not established 3a The IPU 360 processes and sends packets with information to the IPU 100 that communication begins feasible At this time the CALL OUT LED turns ON 4a This indication remains active until the user releases the call button At which the IPU 1025 reports to the installation server the call cancelling and when the cancellation is accepted then the CALL OUT indication is turned off releasing all resources used during communication IPU 360 E IPU 100 ade Gy DEVICE CALL ON OK FAULT IN OUT CONFIG NET USB gt o oo oo 90O Jm ACTIVITY ENGINEERED AND MADE IN E U Encoding directly the audio signal connected to INPUT of the IPU 1025 the device is able to detect the audio modulation and generate a call to the extension that has been programmed on the Webserver The IPU 360 Public Address IP manager will determine the priority and connect the call to the appropriate paging zones Later will confirm the call to the IPU 1025 audio encoder which turns on the CALL OUT LED While audio modulation was present or remote input was active the IPU 1025 input will be encoded and sent through the IP network showing your work status through the LED CALL OUT Installation Configuration Use IPU 1025 ROWY 610 440A 5 29 IPU 1025 P O O Pe IPU l00 e UGC DEVICE CALL ON OK FAULT IN OUT CONFIG NET USB OQO OO O B mm t dedu d 2 6 LED DEVICE OK The IP
23. argeable Included Codec G 711 u Law 8 bits logarithmic compression and 8KHz sampling frequency Quality Low As Factory Default G 711 a Law 8 bits logarithmic compression and 8KHz sampling frequency Quality Low G 722 ADPCM 8 bits Adaptive Linear Compression and 16KHz sampling frequency Quality Medium PCM 16 bits without compression and 8KHz sampling frequency Quality Good PCM 16 bits without compression and 16KHz sampling frequency Quality Very Good REMOTE IN input switch type Close Contact to start and hold the out coming call Open Contact to cancel the out coming call VOX control Threshold level and Pre Post activation time settings Using the Webserver built in in the device the following remote features are available Functionality Supervision Password Management Configuration of SIP LAN Time Date Device Password system of 8 alphanumeric characters Main AC Adaptor recommended 24Vdc IPW 25 0 9A PPTC internal fuse resettable Backup Battery external 24Vdc 18 30V 0 9A PPTC internal fuse resettable 32W m x at 24Vdc IPU 100P mode 38W 5 a 45 C 0 a 40 C recommended 15 a 60 C 5 a 95 witthout condensation 0 6 Kg RGW 610 440A 3 29 IPU 1025 je UGC 3 TYPICAL APPLICATION OF IPU 100 3 TYPICAL APPLICATION OF IPU 100 Figure 1 provides an example configuration of the PAsystem for IP networks of UDE The audio decoder IP
24. citando un nombre de usuano y una contrase a El sitio dice Protected Nombre de usuano Contraiena Attention Computer security is a crucial aspect in IP networks Technical staff is recommended not to store the password default on computers where you can access unqualified personnel to modify the settings of IP equipment Installation Configuration Use IPU 1025 OWI 610 4404 8 29 IPU 1025 ade 00 27 19 5 FRI 17 05 7013 UNION DESARROLLOS ELECTRONICOS Configuration Summary Status Monitor Main Version Webserver Version v1 455 18 06 01 4 V1 225 5406 2014 LED ek to toggle MAC Address QU 04 ADE IP ode STATIC MANUAL POWER ON Host Hame Pigg a SERVER DAAN IP Addgess Subimet Mask 18218680 238 1255 255 255 0 REGISTER On Gateway 198245801 N CALL IN DNS Seres d DIES Sewer 7 13216801 0 0 00 CALL OUT SIP Sewer IP 192 168 000 254 NES 05060 f 560 psom 2003 I 2003 Auth Device Extension Auh Password 2003 7 Default Call tre ani 3002 EXTERMALS UDE PA Systeme ON SIP Receiver Priority Levet EU x TL N MOLINE SIP Streaming Priority Level i TL OUT SPEAKER SIP Paging Desk Priority Level 10 vox ACTIVED SIP Paging Dask Hama PUL Evac Paging Desk PHANTOM ACTIVED RPU TOM Mode PLITOOP NORMAL Moll Codec G T22 ADPCHM Bids 16KHz Audio lll Type Phantom Mode LINE Type OFF BEEPER Mode VOX Bode Threshold ON PFOFF 10v FreVox Time PostVOX Time seconda ps 010 TM GUT Activation
25. e the connection to the installation server IPU 360 SIP server The parameters configured here must be consistent with SIP server parameters of the system 00 30 53 FRI 17 05 2013 UNION DESARROLLOS ELECTRONICOS IPU 1025 This page allows the configuration of the SIP s board settings Enter the new settings for the board below Enable SiP changes 7 UDE PA System DH ow SIP Server IP 182 168 000 254 Remote port sd Local Port USED UDP Local Pott Device Extension Username i Athen Device Extension iUsernanme tana Display Hare Caller ID Manne D Default Call Streaming SIP Pec rv et Priority Level iNaxs nint SIE SIP Str earning Priority Level Maxi minit Reset to Factory Ipu TeaP SIP Paging Desk Priority Level Maat nins Time to Expire Register seconds MAX T2690 minii Reboot IP Desk lane PLLTOUP Evac Paging Desk Seve SIP Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sani Joan Despi Barcelona Tel 34 09 477 28 54 Fax 34 03261 17 52 The configuration parameters are Enable SIP changes In case the checkbox is checked the SIP parameters are available to be configured If not the configuration parameters are blocked UDE PA system The signaling communication with the server is SIP Furthermore due to the public address characteristics the codifiers and decoders requires additional information inside the standardized datagram Choose ON to
26. er it to the ground use isolation Installation Configuration Use IPU 1025 ROW 610 440A 7 29 IPU 1025 ga 5 DEVICE CONFIGURATION WEBSERVER The IPU 1025 configuration is done by accessing to the IP address assigned to the device by the site administrator if you work in Manual mode assignment Static Mode or by the DHCP server if you work in automatic mode Static IP by default is 192 168 0 210 5 1 HOME PAGE Home The HOME page of the IPU 100 WEB application allows everyone access to configuration menus and display the status variables of the encoder decoder 00 27 13 5 FRI 17 05 2013 UNION DESARROLLOS ELECTRONICOS Configuration Summary Status Monitor Main Wei ahoi Webserver Vei sione y1 45S TADEG Wd 25 DS 4 Lita chck t bop MAC Address QU 04 AX C9 21 3E IF Mode STATIC MANUAL N POWER ON Host Hame Puto SERVER CHAAN IP Add ess Subimet Mask 1821680 238 1255 255 255 0 REGISTER On Gale un any 19231580 1 N CALL IN DNS Seres d DIES Serger 7 13216801 0 000 CALL OUT SIP Sewer IP 192 168 000 254 N NF p5n65 s m5n6n D5004 oer Auth Device Extension Auth Password 2003 7 Default Call tre aninaic 3002 EXTERHMALS UDE PA System ON r SP Receiver Priority Level A x TL IN MICALINE SIP Streaming Priority Level i 5 TL OUT SPEAKER EM SIP Paging Desk Priority Level 10 VOX ACTIVED Password SiP Paging Doak Hare EL DOP Evac Paging Desk PHANTOM ACTIVED IPU DP de PUTODP NORMA
27. ets should be the LED blinking LED CONFIG This indicator shows that session of configuration Setup by Webserver is open NOTE This LED appears blinking orange while WEBSERVER session is open although the operator administrator has finished with maintenance It is desirable to close the work session when this is over to indicate properly the status and do not allow confusion with front indicators LED CALL IN This indicator is set when an incoming call active decoder mode is received and accepted and is active while the call emitter keep the channel open Once emitter point drop the call the server of the installation disable the call and the CALL IN indicator will turn off When the LED remains off indicates that the IPU 1025 is not getting any calls LED CALL OUT This indicator is activated when the IPU 1025 device is the generator of a voice call there are two types of call Using a IP Paging Desk Controller IPU 100P connected to the IPU 1025 reports that the user is performing an outgoing call to one or more areas So that the LED is turned on the following sequence of events must happen 1a The IPU 100P device makes a request to the IPU 1025 to provide an outgoing call to one or more paging zones selected by touch screen and Pressing the PTT button talk 2a The IPU 1025 processes the request and sends the information through the IP network to the server to communicate with selected decoders The Call Out LED has not yet been
28. f IP decoder with built in amplifier allows savings in space power and price of the final device The IP system is suitable for any type of installation schools sports centers industrial areas department stores airports etc It is recommended for remote management applications such as Remote management of parking remote management facilities on installation that require sound systems The IPU 1025 allows encoding and decoding multiple audio formats such as G 711 and G 722 suitable for Voice and PCM suitable for Background Music environment applications The IPU 1025 may be operated in two different ways making it very versatile in any installation 24V AC Adaptor 18 30V 24V backup battery 18 30V The IPU 1025 configuration by the technician is done by accessing to the integrated Webserver using a password but if the user or operator needs to monitor the status of it then also can be done remotely just knowing the IP address of the device Installation Configuration Use IPU 1025 ROMY 610 440A 2 29 IPU 1025 TECHNICAL FEATURES CPU Principal LAN port Ethernet AUDIO LINK port INPUT port SPK port USB port LEDs only informative System Clock Backup Supply Audio Format Encoder Outcoming Call to default extension activation Remote Management Security Level Power Consumption Operation temperature Storage temperature Humidity Weight Installation Configuration
29. ignal OFF as Factory Default ON PreVOX time format XXX Select between 000 and 120 seconds the time it will spend in the detected signal condition before being made the audio streaming activation call Always use a 3 digit format Example 000 010 120 PostVOX time format XXX Select between 000 and 120 seconds the time it will spend in the no signal condition before being canceled the audio streaming call Always use a 3 digit format Example 000 010 120 VOX Level format X X Selects the minimum threshold for detecting the audio signal as active Always use a 3 digit format minimum 1 0V maximum 3 3V Example 1 1 2 7 3 3 Output Volume format XXX Select between 025 and 128 the volume applied to the output which you connect the amplifier Always use a 3 digit format Example 025 m n 080 128 max Output Bass Gain Filter can be used to supplement the low frequency response from 0dB default set to 15dB Example 0dB m n 15dB max Output Bass Cut off Frequency Filter cut off frequency for supplement low frequency response Example 20Hz m n 150Hz max Installation Configuration Use IPU 1025 ROWY 610 440A 23 29 IPU 1025 Output Treble Gain Filter can be used to attenuate supplement the high frequency response from 12dB to 10 5dB Example 12dB max atenuation 0dB default 10 5dB max gain Output Treble Cut off Frequency Filter cut off f
30. ing Desk connected to the AUDIO LINK For more details refer to the User Manual of the IPU 100P IP Paging Desk Attention Do not use the IPU 100P Mode when no IP Paging Desk is connected to the AUDIO LINK terminal as it can lock the IPU 1025 temporarily until you perform a reboot of the device VoIP Codec Allows selection of the codec to be used to encode both outgoing and incoming calls when the audio source is a microphone The options are as follows G 711 u Law 8 bits logarithmic compression and 8KHz sampling frequency Quality Low As Factory Default G 711 a Law 8 bits logarithmic compression and 8KHz sampling frequency Quality Low G 722 ADPCM 8 bits Adaptive Linear Compression and 16KHz sampling frequency Quality Medium PCM 16 bits without compression and 8KHz sampling frequency Quality Good PCM 16 bits without compression and 16KHz sampling frequency Quality Very Good Installation Configuration Use IPU 1025 ROWY 610 440A 22 29 IPU 1025 S BEEPER function Activate the acoustic buzzer OFF as Factory Default ON Phantom POWER Enable the 12V phantom power on MIC input line OFF as Factory Default 12VDC Audio IN Select which audio source will be used in streaming mode of the two possible ones MIC Type as Factory Default LINE Type VOX function Allows the function of streaming is activated by the VOX controlled method activate the equipment to detect an audio s
31. ith the IPU 1025 The standard default value is 00000 automatic mode you should keep this value to ensure compatibility with different SIP servers Remember to always use a configuration with 5 digits Example UDP Remote Port 00000 UDP Local Port format XXXXX Defines the data transmission UDP port Voice INFO used by the IPU 1025 to communicate with the IPU 360 SIP server on the installation The standard default value is 05004 and it is recommended to keep compatibility with different SIP servers Remember to always use a configuration with 5 digits Example UDP Local Port 05004 Device extension username from 4 to 8 numbers It is the IPU 1025 SIP identifier for registering to the IPU 360 SIP server to be identified as unique equipment in the SIP net of the public address by IP protocol In the systems with UDE Audio equipments the extensions must be contained in a specific rank Extensions from 1000 to 1999 Decoders Extensions from 2000 to 2999 Audio codifiers Extensions from 3000 to 3999 Music on hold equipments do not use in other codifiers decoders configuration Extensions from 4000 to 4999 IP desk control with IPU 100P Choose the extension number depending in which application the IPU 1025 should work Some extensions ranks have additional features Codifier extension between 2000 and 2499 do not activate the TM OUT in the decoder Codifier extension between 2500 and 2999 activate the TM OUT in the decode
32. label 2 Extension to call 001 equal to 1001 3 Confirm extension with Add EXTENSION 4 Extension 1001 appears in the extension box 5 In button number one has only one extension to call 1001 there is no other extension to configure and configuration must be uploaded Click on button Send data Button 1 configuration has been saved and screen shows the new button IPU 100P Paging Desk Installation Configuration Use IPU 1025 OMY 610 440A 19 29 IPU 1025 Ja 5 DEVICE CONFIGURATION WEBSERVER CAUTION Incorrect settings may cause IPUTOOF failure Please be sure you press Exit for closing properly the edit session If you have doubts about parameters please contact with the Network Admin BUTTON 2 EDITION Group Definition 002 Group ID s001 of 250 croup tame Comedor Remove GROUP xtension Assiqnament Main room Extension ID 2001 af 250 eo e Dials DXX 002 Acid EXTENSION iG 3 E 1001 to 1250 1002 1400 o0 o 5x BUTTON 2 EDITION The parameters to configure for button 2 1 Button 2 label 2 Extension to call 002 equal to 1002 3 Confirm extension with Add EXTENSION 4 Extension 1002 appears in the extension box 2B Type the second extension to call in button 2 this is extension 400 equal to 1400 3B Confirm extension with Add EXTENSION 4B Extension 1400 appears in the extension box 5 In button number two has only two extensions to call 1002 1400
33. must be uploaded Click on button Send data Button 3 configuration has been saved and screen shows the new button du 9 00 00 ude IPU 100P Paging Desk 1001 002 003 Zone 1 Main room Yard Installation Configuration Use IPU 1025 OWA 610 440A 21 29 IPU 1025 5 4 DEVICE CONFIGURATION Device This section allows you to configure the analog parameters and modes of the device red rb v SUM 20 01 2013 UNION DESARROLLOS ELECTRONICOS Piel C K Time 54cond 000 1 20 PaosP 0x Tame seconds DOO 1 70 VOX Level Threshold volts 1 0 3 3 Output Volurne D75 128 Output Bass Gain 0 c6 Getpal Trete Gaii 008 LINE IN Volume D05 115 TM OUT Actrvabon Mode Oti _Save DEGE Copynghi 6 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Desp Barcelona Tel 34 93477 28 54 Fax 34 93 281 17 52 IPU 100 Mode To set the mode of the IPU 1025 between 3 options SPEAKER Receiver The IPU 1025 behaves as audio reception point and is ready to receive calls ONLY This option is set by Factory default TREAMING Emitter The IPU 1025 will act as an audio emitter point and it will be ready to make calls ONLY VOICE MUSIC The streaming is always done to the extension configured as Default Call in the SIP configuration section IPU 100P Normal The IPU 1025 will act as an audio emitter point VOICE mode being synchronized with the IP Pag
34. ord type operator admin supervis then enter the information requested OLD password 8 alphanumeric characters with ASCII between 32 and 127 NEW password 8 alphanumeric characters with ASCII between 32 and 127 Type again NEW password 8 alphanumeric characters with ASCII between 32 and 127 Confirm password Save PASSWORD Attention The new password will take effect only if the old password has been entered correctly and has not been wrong to confirm the new password The system will reset to the new password take effect Installation Configuration Use IPU 1025 RGW 610 440A 28 29 IPU 1025 5 9 RESET TO FACTORY Reset to Factory The IPU 1025 can be configured with the factory configuration 18 11 28 TUE 1155372014 LADDA GEAR LO GL TFC OE Reset t Factory Default CALTON The action could requaed to know spuien parameless fo setup amd seconnect agam the dewce H you have doubt please dom Reade bo conLact wath the Meteors hime Do you want ta RESET fur board io FACTORY DEFAULT H you hren double planae CANCEL RERET h ACIOA L E Pat een in Fariwy E Copynghi amp 2013 AO DESARROLLO ELEC T Se Aeda Buaecelona M 389 joan ep acetone Te 524 91 67T QU DA Fac 3091 L BI 34 Caution The erasing process is irreversible in case of error the memory information cannot be recovered 5 10 REMOTE REBOOT Reboot The IPU 1025 can be remote rebooted just click to the
35. ork temporarily This address can be not necessary for the normal use of your device then assign a null address 000 000 000 000 or simply leaves it blank Example of valid Alternative DNS Alternative DNS IP 000 000 000 000 Secondary DNS IP by Factory default Save NETWORK For the changes to be validated must be pressed the button Save Network As these changes modify the essential connection parameters IPU 1025 mustbe reset and thatis why the Reboot In Progress screen is displayed temporary TION Incorrect satire ay Cause Tee board t lese network connective H you Meee doubts about Daranmeters please dort hestme w Contact wf Pe Network Aden Installation Configuration Use IPU 1025 ROWY 610 440A 26 29 IPU 1025 cda 5 DEVICE CONFIGURATION WEBSERVER 5 6 TIME CONFIGURATION Time Select hour minute and second on the 24h format and always using 2 digits Click on Save TIME to update the system clock 22 45 95 SUM 20 01 2013 UNION DESARROLLOS ELECTRONICOS This page allows the configuraton of the TIME s board settings Enter the new settings for the board below Hour hh Minute rum Seconda 25 SmemTu Always use the format hh mm ss Example Hour hh 22 Minute mm 45 Seconds ss 55 Copynght amp 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sani Joan Despi Barcelona Tel 34 83477 28 54 Fax 34 83 261 17 52 5 7 DATE CONFIGURATION Date En
36. r All extensions between 4000 and 4999 will activate the decoder TM OUT Example Local Extension 1002 2536 1589 4001 Authen Device Extension Username Max 8 alphanumeric characters Defines the user id in the system when it is working in a secure transmission mode Example Authen ID 12345678 AreaCo 1 This parameter is optional if not required then leave it blank Attention If you have questions about your authenticated user name or password contact your Network Administrator or technical staff in charge of the IPU 360 configuration SIP server Basic Alphanumeric characters are recommended standard ASCII codes between 32 and 126 excluding special characters or accents to avoid to block the access in case of any network device or the server does not understand these characters Installation Configuration Use IPU 1025 ROAY 610 440A 11 29 IPU 1025 qa Authen Secret Password Max 8 alphanumeric characters Defines the user password when it is working in a secure transmission mode Example Authen PASSW zX_0 No utilizar caracteres especiales This parameter is required if the parameter Authenticated ID is active otherwise please leave it blank Display Name Caller ID Name format XXXX Default Call Streaming format XXXX Define the extension to call forr activating the background music or for the voice message broadcast from a microphone Valid values for any extension
37. r microphones Time to Expire Register seconds MAX 7200 min 0060 Register time for SIP server update recommended time 3600 seconds SIP Desk Name Max 32 alphanumeric characters The IPU 100P desk control has a label identification name in the main screen to identified from other desk control in the installation SIP Desk Name Hall Hotel Las Vegas 20 characters including spaces Installation Configuration Use IPU 1025 ROMY 610 440A 12 29 IPU 1025 ga 5 3 EXTENSION SIP CONFIGURATION ONLY IPU 100P mode The public address zone configuration with an IPU 100P desk control must be done with a IPU 1025 codifier It is not possible to make the desk control configuration with the touch screen The extension web server of the IPU 1025 menu will allow erasing all IPU 100P zone buttons or editing the PA buttons of the IPU 100P desk control IPU 100P UTP Cable Protocol RS 485 AUDIO IPU 1025 ade GEES IPU 100 UTP Cable IP protocol UTP Cable IP protocol ORDENADOR CON CONEXION A RED Installation Configuration Use IPU 1025 OWY 610 440A 13 29 IPU 1025 Ja The screen structure of the IPU 100P is IPU 100P Paging Desk The main page have 10 PA buttons and navigation icons Each button zone can be edited with a description text and numbers of zones to call decoders The maximum number
38. re the working mode enabled on your IP network to determine whether IP address allocation is automatic AUTO or static fixed If the required operating mode is AUTO then you must enable this mode on the box marked Enable DHCP Attention It is highly recommended for the correct operation of the IP AUDIO equipment of UNION DESARROLLOS ELECTRONICOS that the IP address of each IPU 1025 devices on the network is set to STATIC mode and be a fixed address Host Name Max 15 Characters 1 Defines the name of our IPU 1025 within the group of interconnected devices to differentiate it from the rest in a character format Follow NETBIOS format that enable us to access your device from a web browser without knowing its physical IP address user being easier to remember since you can assign a name representative of the function or area where it is being serviced Example Host Name NETBIOS IPU100 Host Name por defecto de f brica IPU100 HALL OFFICE 1STFLOOR CHECKOUT LANE 3 1 NETBIOS Restriction 15 alphanumeric characters with basic punctuation characters period hyphen underscore and NO spaces Installation Configuration Use IPU 1025 ROWY 610 440A 25 29 IPU 1025 IP Address format XXX XXX XXX XXX Parameter to set the IP address of the device It is required that the address contains the 12 numbers along with the 3 breakpoints A valid example of configuration would be Example IP device 192 168 000 210 IP
39. requency for attenuate supplement high frequency response Example 1kHz m n 8kHz max MIC IN Volume format XXX Select between 088 and 128 the gain level to be applied to microphone connected to IPU 1025 Always use a 3 digit format Example 080 m n 090 128 max LINE IN Volume format XXX Select between 005 and 128 the gain level to be applied to the signal line connected to the IPU 1025 Always use a 3 digit format Example 005 m n 050 128 max DESK MIC IN Volume format XXX Select between 070 and 127 the gain level to be applied to audio from the desk control IPU 100P connected to the IPU 1025 This configuration parameter can only be used in IPU 100P mode Always use a 3 digit format Example 070 m n 090 127 max EXT MIC IN Volume format XXX Select between 010 and 128 the gain level to be applied to audio from the external microphone of the desk control IPU 100P connected to the IPU 1025 CM 23 is the recommended microphone This configuration parameter can only be used in IPU 100P mode Always use a 3 digit format Example 010 m n 090 128 max TM OUT Activation Mode There are few input calls depending on the extension that allow the activation of this mode OFF ON voice calls Any incoming call with the server specifications will activate the TM OUT ON all calls Only incoming calls from desk control IPU 100P will activate the TM OUT SERVER SPECIFICATIONS Codifier e
40. ter the day month and year desired considering always use 2 digits format Click on Save DATE to update the system calendar 22 46 29 SUN 20 01 2013 UNION DESARROLLOS ELECTRONICOS Thes page allows the configuration of the DATE s board settings Enter the new settings for the board below Day dd 2o Moath mm o1 Year yy Save DATE Always use the format dd mm yy Example Day dd 20 Month mm 01 Year yy 13 Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despi Barcelona Tel 34 93 477 28 54 Fax 34 93 261 17 52 Installation Configuration Use IPU 1025 MIA 610 440A 27 29 IPU 1025 5 8 PASSWORD CONFIGURATION DEVICE Password The factory login and passwords are 18 08 03 TUE 11 0 2014 UNION DESARROLLOS ELECTRONICOS This page allows the configuration of the PASSYORD s board settings CAUTION If you forget the password or d you have doubts about how to proceed to anew one please don t hesitate to contact with the Network Admin Selec Login User and enter the new password for the board below Extension Device Did Password DOUCUCKX X ew Password MME KI Repeat How Password KAA EXE Save PASSWORD f Rabani SIP Copynght amp 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despl Barcelona Tel 34 83477 28 54 Fax 34 83 261 17 52 To change the password first select the desired passw
41. use the UDE PA signaling information In case of priority or IPU 100P installations the box must stay in ON option In case of 100 SIP standard compliance OFF option SIP Server IP Address format XOOCXXX XXX XXX Defines the IP address where the SIP server host It is required that the address contains the 12 numbers along with the 3 breakpoints Example SIP Server IP 168 168 0 254 j Attention i It is MANDATORY for the correct operation of the IP AUDIO devices of UNION DESARROLLOS ELECTRONICOS that the SIP Server IP address is FIXED address static type Installation Configuration Use IPU 1025 ROWA 610 440A 10 29 IPU 1025 j Remote Port format XXXXX Define the management TCP port used by the IPU 360 SIP server to communicate with our IPU 1025 The standard default value in the device is 05060 you should keep to ensure compatibility with different SIP servers Remember to always use a configuration with 5 digits Example Remote Port 05060 Local Port format XXXXX Define the management TCP port used by the IPU 1025 to communicate with the IPU 360 SIP server The standard default value in the device is 05060 you should keep to ensure compatibility with different SIP servers Remember to always use a configuration with 5 digits Example Local Port 05060 UDP Remote Port format XXXXX Defines the data transmission UDP port Voice INFO used by the IPU 360 SIP server to communicate w
42. xtension between 2500 and 2999 activate the TM OUT in the decoder All extensions between 4000 and 4999 will activate the decoder TM OUT Installation Configuration Use IPU 1025 Rea 610 440A 24 29 IPU 1025 S 5 5 CONFIGURATION LAN Network This section describes how to set NETWORK configuration parameters basic to any local area network LAN Follow the steps below 18 06 47 TUE 11 03 2014 UNION DESARROLLOS ELECTRONICOS This page allows the configuration of the NETWORK s board settings Enter the new settings for the board below contact with the Metwork Admin Pew H CAUTION Incorrect settings may cause ihe board to lose network connectivity IF you have doubts about parameters please don t hesitate to MAC Address CEE E Fat LAN changes Enabie DHCP r Hirst Hamer fiero IP Address 192 1880 242 Subnet Mask 255 255 255 0 paia O Gateway 021080100 Exiansion Primary ONS 0858851 Password Alternate DNS fa 0 000 Resello Factory Copyright 2013 UNION DESARROLLOS ELECTRONICOS Avda Barcelona 24 Sant Joan Despi Barcelona Tel 34 93 477 28 54 Fax 34 93 761 17 52 The configuration parameters are Enable LAN changes When this option is unchecked the status of the current connection is shown Check the Enable LAN changes to modify any of them Note that after setting this option the other options are enabled Enable DHCP Ask the network administrator to ensu

Download Pdf Manuals