1. teindre le disjoncteur avant de le d brancher ou d connecter l unit partir des lignes de services Page 10 EV40 User s Manual For Hollow Wall Construction e Place the unit such that both mounting holes can take advantage of solid structural framing of the outside wall or a strong wall surface such as plywood e Size 1 4 20 lag screws are recommended for mounting the EV40 to a wooden structure Pre drill approximately sized pilot holes to allow the lag screws to grip the wooden structure while preventing the wood from cracking or splintering while the screw is fastened e The included plastic angle washers can be oriented to allow the lag screws to be fastened at an angle while still providing a solid flat backing to the screw head e If the the screw head is smaller than the 3 8 washer aperture an additional flat washer will need to be placed between the plastic angle washer and the head of the lag screw e If either mounting hole does not have a solid mounting structure such as a drywall without a solid backing it will be necessary to use proper anchoring hardware such as drywall toggles or molly bolts Figure 5 Mounting the EV40 to a hollow wall Nate Diagonal Mount Washer is marked with an 07 dape Diagonal Perpendicular Screw Mount Screw Mount FE Longer M U IN N N Page 11 EV40 User s Manual For Solid Wall Construction e To secure the unit in concrete
2. pre drill appropriately sized holes and use multi set or wedge anchor hardware at both mounting points e To secure the unit in brick or stone pre drill appropriately sized holes and use sleeve anchors at both mounting points The included plastic angle washers can be oriented to allow bolts to be fastened at an angle or perpendicular to the mounting surface Note there are two different sets of plastic angle washers included Select those washers that best accommodate the mounting hardware angle of attack and orient them accordingly If the head of the mounting hardware is smaller than the 3 8 plastic angle washer aperture an additional flat washer will need to be placed between the plastic angle washer and the head of the mounting hardware Machine screws size 1 4 20 hardware is recommended for mounting the EV40 Screw shafts of at least 2 are recommended The EV40 plastic angle washer hole size is 3 8 in diameter so ensure that the screw heads are of a larger diameter Place appropriately sized washers between the screw heads and the EV40 enclosure mounting flanges Figure 6 Mounting the EV40 to a solid wall A hie Note Diagonal Mot Wade fe marked with o an O shape ig N COUNTRY Diagonal Perpendicular Seren Mount Screw Moum 17 ic x ik LS U Page 12 EV40 User s Manual Mounting the SAE J1772 Connector Holster The SAE J1772 connector holster is an available option
3. transformer manufacturer s literature to be sure the single leg can supply the required power Attention Avec la connexion en triangle une borne doit tre centre tapped et seulement les deux phases d un c t ou du l autre de centre tap peut tre utilis e Les deux phases doivent mesure 120V Neutre La troisi me ligne L3 du delta est 208 V par rapport la position Neutre et il est parfois d signe comme un stinger Ne pas utiliser ce troisi me ligne Consultez la documentation du transformateur fabricant pour tre s r de bome unique peut fournir la puissance requise EV40 User s Manual Caution A 3 phase delta connected transformer secondary without a center tap on A one leg cannot be used the the EV40 No neutral point is available to be connected to ground for ground fault protection The EV40 Charger will not allow the contactor to close if it does not sense the presence of a ground wire connected to a neutral point on the transformer secondary Attention Un triphas triangle connecte transformateur secondaire sans centre tap sur le terminal ne peut pas tre utilis avec la EV40 Aucun point neutre est disponible pour tre Mise la terre pour protection de d faut la terre Le EV40 ne permettra pas le contacteur de fermer si elle ne d tecte pas la pr sence d un fil de masse connect un point neutre sur le secondaire du transformateur MOUNTING PROCEDURES Locate the wall mount
4. 3 phase delta connected With center tap on one leg must use only the two phases on either side of the center tap The two phases must both measure 120V AC to ground Do not use the third leg 208V stinger EV40 and EV40P LI L2 and Safety Ground use 8AWG 75 C copper wire 185V AC to 264V AC 60 Hz Circuit Maximum Output EV40 Model Breaker Current Power EV40 Hardwired 40A 30A 7 2KW EV40P 14 50 plug 50A 30A 72KW Not that the maximum current for the vehicle is set by the duty cycle of the Pilot waveform Output power is variable depending on the EV40 model and vehicle demand Attached NEMA 14 50P plugs is available on the EV40P Height 500 mm 19 7 in Width 225 mm 8 9 in Depth 135 mm 5 3 in 6 0kg 131bs 25 feet Operating Temperatures 30 C to 50 C 22 F to 122 F Storage Temperatures 40 C to 80 C 40 F to 176 F Enclosure Rating NEMA 4 watertight ETL listed FCC Part Class B EV40 User s Manual WARRANTY INFORMATION LIMITED WARRANTY ELECTRIC VEHICLE SUPPLY EQUIPMENT MODEL EV40 Sun Country Highway Ltd 306 Saskatchewan Crescent Saskatoon SK S7N 0K6 1 866 467 1371 Sun Country Highway shall provide the following warranty with respect to the Products to Representative its Sub Representatives and their customers Product 3 year parts 3 year factory labor Sun Country Highway Inc warrants this product to be free from defects in material and workmanship The warrantee pe
5. Figure 2 220 240V Single Phase Figure 3 208V 3 Phase Wye Connected 7 L1 L3 NOT USED 120V j gt gt NEUTRAL 240V 1 NOT USED gt gt 120V LU P L2 GND GND Note With a wye connected secondary any two of the legs can be used to provide 208V to the EV40 Charger For example L1 amp L2 or L1 amp L3 or L2 amp L3 Leave the unused leg open Do not connect it to a Neutral bar or to Ground Be sure the center point is grounded to earth somewhere in the system Remarque Avec un transformateur toile connect secondaire deux des jambes lignes peut tre utilis pour fournir 208V a la EV40 Par exemple L1 amp L2 ou LI amp L3 L2 amp L3 Laisser la borne inutilis e ouverte Ne le connectez pas un bar Neutre ou la terre Assurez vous que le point central est mis la terre quelque part dans le syst me Page 8 EV40 User s Manual Figure 4 240V 3 Phase Delta Connected with center tap on one leg Page 9 C L3 NOT USED 4 esse L1 120V NEUTRAL NOT USED 240V 120V L2 GND Caution With the delta connection one leg must be center tapped and only the two phases on either side of the center tap can be used The two phases must both measure 120V to neutral The third line L3 of the delta is 208V with respect to neutral and is sometimes referred to as a stinger Do not use this third line Consult the
6. a compact wall or pedestal mounted charging station that provides the Plug in Hybrid or Battery Electric Vehicle together Plug in Electric Vehicles or PEV user with a safe and manageable link between the power grid and the PEV Both hardwired EV40 and NEMA plugin equipped EV40P versions are available The EV40 is very easy to use Just unwrap the SAE J1772 charge cable and plug the charge coupler firmly into the vehicle s charge port Normally the vehicle will immediately request a charge using a special communication line in the cable Within a few seconds the green Charging light on the face of the EV40 will turn on and the charge cycle will begin After an average driving day the vehicle battery will require a few hours to recharge completely Charging overnight is the most convenient way to maintain healthy batteries and ensure you vehicle s full range will be available for the next day When the vehicle has stopped charging the green Charging light on the EV40 will turn off To remove the charge coupler once the charge cycle has competed or to interrupt a charge in progress press and hold down the latch release lever on the charge coupler handle then un plug the charge coupler from the vehicle charge port Page 4 EV40 User s Manual THE EV40 FRONT PANEL The front panel on the EV40 has four indicator lights POWER yellow indicates that power is available to the EV40 CHARGING green indicates th
7. breaker panel before servicing or cleaning the unit Attention Couper l alimentation d entr e votre station de recharge sur la panneau de disjoncteurs avant de nettoyer ou de r parer l appareil VENTILATION Some electric vehicles require an external ventilation system to prevent the accumulation of hazardous or explosive gases when charging indoors Check the vehicle s owner s handbook to determine if your vehicle requires ventilation during indoor charging VENTILATION Certains v hicules lectriques n cessitent un syst me de ventilation externe pour viter l accumulation de gaz explosifs ou dangereux lors de la charge l int rieur Consultez le manuel du propri taire du v hicule pour d terminer si votre v hicule n cessite une ventilation quand le recharge en salle Note Vehicles which conform to the SAE J1772TM standard for communication with the charging station can inform the charge station that they require an exhaust fan The EV40 Charger is not equipped to control ventilation fans Do not charge the vehicle with the EV40 if ventilation is required Remarque V hicules qui sont conformes la norme SAE J1772 TM de communication peuvent informer la station de recharge qu ils n cessitent un ventilateur d extraction Le EV40 n est pas quip pour contr ler les ventilateurs Ne chargez pas le v hicule avec le EV40 si la ventilation est n cessaire Caution DO NOT charge your vehicle indoors if it requires ven
8. to provide a convenient protective housing for the SAE J1772 connector head when it is not in use e The SAE J1772 connector holster should be placed so that users have easy and safe access to the SAE J1772 connector e For indoor installation mount the SAE J1772 connector holster between 18 and 48 inches above the ground or grade e For outdoor installation mount the SAE J1772 connector holster between 24 and 48 inches above the ground or grade e The SAE J1772 connector holster has two vertically aligned mourning holes spaced 5 45 apart one each on the enclosure top and bottom Use a ruler or template to mark the hole locations on the mounting surface e The vertical alignment of the EV40 and SAE J1772 connector holster mounting holes allows for the convenient mounting of both components onto the same post or wall structure For example the holster may be mounted directly above the EV40 e Place the SAE J1772 connector holster such that both mounting holes take advantage of solid structural framing inside the wall or a strong wall surface such as plywood e A set of exterior wood screws and stainless steel washers are included for the purpose of mounting the SAE J1772 connector holster to a wooden surface e For mounting to a solid surface such as concrete brick or stone alternate hardware may need to be procured Examples of solid wall mounting hardware include multi sets wedge anchors and sleeve an
9. your nearest authorized Service Representative or Sun Country Highway at the above number You will receive information as to how service for the product will be provided If you mail or ship the product in for service you must insure the product prepay all shipping charges and properly pack it for shipment in its original shipping container or its equivalent You are responsible for all loss or damage that may occur in transit You must provide proof of purchase of the product and the purchase date before any warranty service can be performed This limitation applies to damages of any kind including any direct or indirect damages lost profits lost saving or other special incidental exemplary or consequential damages whether for breach of contract tort or otherwise or whether arising out of the use of or inability to use the product even if Sun Country Highway or an authorized Sun Country Highway representative or dealer has been advised of the possibility of such damages or of any claim by any other party Some states do not allow the exclusion or limitation of incidental damages for some products so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state Page 19 EV40 User s Manual Page 20 SUN COUNTRY HIGHWAY Sun Country Highway 306 Saskatchewan Crescent Saskatoon SK S7N OK6 1 866 467 1371 info suncountryh
10. D SUN COUNTRY GREENING THE WORLD S HIGHWAYS Users Manual EV40 SUN COUNTRY PLEASE NOTE This user s manual includes the latest information at the time of printing Sun Country Highway Inc reserves the right to make changes to this product without further notice Changes or modifications to this product by other than an authorized service facility could void the product warranty If you have questions about the use of this product contact your customer service representative Refer to the Customer Support section located in this guide EV40 User s Manual Version 01 May 2014 Copyright 2014 Sun Country Highway Ltd AII rights reserved CONTENTS IMPORTANT SAFETY INSTRUCTIONS ADDITIONAL SAFETY INFORMATION FCC INFORMATION OPERATION EV40 FRONT PANEL INSTALLATION Service Connections Mounting Procedures Wiring Instructions Grounding Instructions MOVING amp STORAGE INSTRUCTIONS MAINTENANCE CUSTOMER SUPPORT SPECIFICATIONS WARRANTY INFORMATION 10 14 15 15 16 16 Le 18 EV40 User s Manual IMPORTANT SAFETY INSTRUCTIONS Carefully read these instructions and the charging instructions in your vehicle owner s handbook before charging your electric vehicle The following symbols may be found in your handbook or on labels affixed to your conductive charge station Note This means pay particular attention Notes contain helpful suggestions Remarque Cela signifie accorder une attent
11. at the vehicle is requesting a charge and AC power is currently applied to the vehicle POWER FAULT red indicates that the EV40 is not wired correctly The problem can be due to improper grounding or a missing Earth Ground The wiring should be examined by a qualified electrician CHARGING FAULT red indicates that the EV40 is unable to communicate with the vehicle correctly or a safety fault condition has been detected by the unit Table 1 Front Panel LED Information Figure 1 The EV40 Front Panel SUN COUNTRY Power CHARGING evCHARGER EV40 Amber Green Red Power Red Power Charging Fault Charging Fault Condition LED LED LED Fault LED off off off off No power to EVSE Check circuit breaker ON off off off ja into EV or EV is not ready to Charging enabled power is applied to the ON ON off off vehicle ON not ON off blinking off Improper grounding or ground is not present ON not Problem with EV communications ON ol oe blinking Disconnect and restart ae EV ground fault trip Check vehicle ON off off Blinking sonn ction ON off Blinking Blinking Internal EVSE fault Call for service Page 5 EV40 User s Manual INSTALLATION Service Connections Page 6 Caution To reduce the risk of fire connect only to a circuit provided with the appropriate maximum branch circuit over current protection in accordance with the National Elect
12. chors Use the type of mourning hardware most appropriate for the supporting structure Figure 7 Mounting the holster using the exterior wood screws and washers Page 13 EV40 User s Manual WIRING INSTRUCTIONS Hardwired Route the EV40 conduit to a nearby service panel or junction box Use the included 1 2 trade sized watertight fitting and sealing washer to provide a moisture resistant seal with the service panel or junction box If necessary drill a 7 8 diameter hole to accommodate the liquid tight fitting Figure 8 Wiring the EV40 in a junction box Page 14 Note Before connecting the EV40 service conductors please carefully read the section of the manual titled Service Connections on page 6 If you are unsure of the type of power provided at the service panel please consult with you local utility or call your service representative for assistance Note The three EV40 service conductors use standard 10AWG 75 C copper wire The insulation of each conductor is colour coded for standard 240VAC installation Green Ground Black Line 1 120VAC to Ground Red Line 2 120VAC to Ground Les trois conducteurs service la EV40 utilisent multibrins 10AWG 75 C fil de cuivre L isolation de chaque conducteur est un cod couleur pour une installation standard de 240 VAC Vert Mise a la Terre Noir Ligne 1 120 VAC Mise la terre Rouge Ligne 2 120VAC Mise la terre EV40 User s Manua
13. e telle sorte qu il ne sera pas pi tin accroch plus du ou autrement endommag ou de subir la stress Ce produit ne contient aucune pi ce r parable par l utilisateur Consultez la section Support la Client le dans ce manuel pour obtenir des informations de service N essayez pas de r parer ou d entretenir la station de recharge vous m me Ne faites pas fonctionner votre station ou le c ble de charge si elles sont physiquement ouverte fissur effiloch ou autrement visiblement endommag Contactez votre repr sentant de service pour service imm diatement Consultez la section Support la Client le dans ce manuel pour obtenir des informations sur le repr sentant du service dans votre r gion Ne pas utiliser dans les garages commerciaux o un garage commercial est d fini comme une installation ou une partie utilis pour la r paration de v hicules combustion interne dans lequel la zone peut tre class e en raison de vapeurs inflammables tant pr sent comme l essence e Ne posez pas vos doigts dans de l int rieur de l extr mit du SAE J1772TM coupleur du c ble de recharge e Ne pas laisser les enfants utiliser cet appareil Supervision d un adulte est obligatoire lorsque des enfants sont proximit d une station de charge qui est en cours d utilisation Page 2 EV40 User s Manual ADDITIONAL SAFETY INFORMATION Page 3 Warning Turn off input power to your charge station at the circuit
14. h measure 120V to Neutral Earth Ground must be connected to Neutral at only one point usually at the Service Entry Breaker Panel Attention Les deux phases utilis es doivent mesure chaque 120V Neutre Misse a la terre doit tre connect Neutre en un seul point g n ralement l entr e panneau de disjoncteurs de service EV40 User s Manual Caution If a 240V 3 phase feed is from a Delta connected secondary the leg used must have a center tap That tap must be Grounded Only the two phases either side of the center tapped leg can be used See Fig 4 below Attention Si une alimentation triphas s 240V provient d un triangle connect secondaire la bornes utilis e doit avoir une centre tap Que la tap doit tre Mise la Terre Seuls les deux phases l une ou de l autre c t du centre tapped brancher peut tre utilis s Voir la Figure 4 ci dessous Caution Warranty is void if this unit is wired improperly ZN Attention La garantie est annul e si cette unit n est pas correctement c bl Warning Only a qualified electrician should perform the installation The installation must be performed in accordance with all local electrical codes and ordinances Avertissement Seul un lectricien qualifi doit effectuer l installation L installation doit tre effectu e conformit tous les codes lectriques locaux et des ordonnances Only 3 wires are connected but care must be taken that the service transf
15. ighway ca Page 21 EV40 User s Manual
16. ing position of the EVSE e On the hardwired EV40 the three service conductors are shielded by three feet for flexible conduit The EV40 must be positioned such that the conduit can reach a nearby service panel or junction box e On the plug in EV40P the NEMA plug head is connected by one foot of cable to the bottom side of the EV40P The charger must be positioned such that the plug can safely be inserted into a wall mounted NEMA socket e The plug in EV40P is intended for indoor use only Currently the NEMA 14 50 and 6 50 plugs and receptacles are not outdoor rated e Position the bottom of the charge station at a comfortable height and at least 18 inches above the ground Ensure that the LEDs on the front panel of the EV40 can clearly be seen by anyone who will be operating the device e The EV40 has two vertically aligned mounting holes spaced 17 apart one each on the enclosure top and bottom Use a ruler or template to mark hole locations on the mounting surface Warning For safety always turn off input power to the charge station at the circuit breaker panel prior to plugging it in or wiring it to the service lines Like wise turn off the circuit breaker prior to unplugging it or disconnecting the unit from the service lines Attention Pour s curit toujours d sactiver le courant d entr e de la station de recharge au niveau de disjoncteurs de panneau avant de brancher ou de cablage a les lignes de services Comme sage
17. ion particuli re Les remarques contiennent des suggestions utiles CAUTION This symbol means be careful You are capable of doing something that might result in damage to equipment ATTENTION Ce symbole signifie tre prudent Vous tes capable de faire quelque chose qui pourrait causer des dommages l quipement WARNING This symbol means danger You are in a situation that could cause bodily injury Before you work on any electrical equipment be aware of the hazards involved with electrical circuitry and standard practices for preventing accidents AVERTISSEMENT Ce symbole signifie danger Vous tes dans une situation qui pourrait causer des blessures corporelles Avant de travailler sur un quipement lectrique tre conscient des dangers pr sentes par les circuits lectriques et les pratiques courantes de prevention des accidents Instructions Pertaining to Risk of Fire or Electric Shock When using the EV40 basic electrical safety precautions should be followed e Use this charge station to charge electric vehicles equipped with a SAE J1772TM charge port only See the vehicle s owner s handbook to determine if the vehicle is equipped with a conductive charge port e Make certain the charge station s SAE J1772TM charge cable is positioned so it will not be stepped on tripped over or otherwise subjected to damage or stress e There are no user serviceable parts inside Refer to the Customer Support section in thi
18. l GROUNDING INSTRUCTIONS The product must be grounded If this product should malfunction or break down grounding provides a path of least resistance for electrical current to reduce the risk of electrical shock For the hardwired EV40 The hardwired EV40 is equipped with three service conductors shielded by three feet fo flexible conduit This product must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the ground lead on the product For the Plug in EV40P The plug in EV40P is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances Warning Improper connection of the equipment grounding conductor may result in a risk of electric shock Check with a qualified electrician if doubt exists as to whether the product is properly grounded Do not modify the plug provided with the product if it will not fit in the outlet have a proper outlet installed Attention Une mauvaise connexion du conducteur de terre peut entrainer un risque de choc lectrique V rifier avec un lectricien qualifi si il existe un doute quant savoir si le produit est correctement mis la terre Ne pas modifier la fiche fournie avec le produit si elle n entre pas dans la prise faites instal
19. ler une prise ad quate par un lectricien qualifi MOVING AND STORING Note that both the hardwired EV40 and the plug in EV40P are intended for fixed installations For mounting requirements consult Mounting Procedures section of the Installation Instructions in the manual Always turn off input power to the charge station at the circuit breaker panel prior to hardwiring an EV40 or to disconnect an EV40 from the service lines Likewise always turn off the the input power to the charge station at the circuit breaker panel before plugging in or unplugging a EV40P from a NEMA socket When transporting the charge station do not lift or carry the entire hit by the SAE J1772 charge cord Likewise do not lift or carry the entire unit by the flexible conduit and input connectors EV40 or the NEMA plug EV40P The Charge station has a non operational storage temperature of 40 C to 80 C 40 F to 176 F Page 15 EV40 User s Manual MAINTENANCE The EV40 Charger requires no periodic maintenance other than occasional cleaning 4s Warning To reduce the risk of electrical shock or equipment damage exercise caution while cleaning the unit and the EV charge connector cable 1 Turn off your charge station at the circuit breaker before cleaning 2 Clean your charge station using a soft cloth lightly moistened with mild detergent solution Never use any type of abrasive pad scouring powder or flammable solvents
20. ormer secondary connection is definitely known and the 3 wires from the main circuit breaker panel are connected and labeled correctly Figures 2 3 and 4 below show the most common service transformer secondary wiring formats Notice that L1 L2 amp Ground are labeled on each diagram Those transformer outputs correspond to the same inputs on the EV40 Charger Also each of the two 3 phase diagrams shows an L3 output which is not used Do not connect all three phases of a 3 phase secondary to the EV40 Charger This is a single phase device The Neutral at the service panel must be connected to earth ground somewhere in the system on any of the three connection arrangements Ground fault protection is not possible unless the Neutral center tap on the service transformer is connected to an earth ground If no ground is provided by the electrical service a grounding stake must be driven into the ground nearby following local electrical codes The grounding stake must be connected to the ground bar in the main breaker panel and Neutral connected to ground at that point Warning Local electrical codes must always be followed when installing the grounding stake Avertissement Les codes lectriques locaux doivent toujours tre respect es lors de l installation du piquet de mise la terre Page 7 EV40 User s Manual The following diagrams illustrate the three service transformer secondary connections most common in North America
21. press and implied warranties for this product including the warranties of merchantability and fitness for a particular purpose are hereby disclaimed Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts so the above limitation may not apply to you If this product is not as warranted above your sole and exclusive remedy shall be repair or replacement as provided above In no event will Sun Country Highway any of its authorized sales and service representatives or its parent company be liable to customer or any third party for any damages in excess of the purchase price of the product Page 18 EV40 User s Manual This limitation applies to damages of any kind including any direct or indirect damages lost profits lost saving or other special incidental exemplary or consequential damages whether for breach of contract tort or otherwise or whether arising out of the use of or inability to use the product even if Sun Country Highway or an authorized Sun Country Highway representative or dealer has been advised of the possibility of such damages or of any claim by any other party Some states do not allow the exclusion or limitation of incidental damages for some products so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state To obtain warranty service Call
22. rical Code ANSI NFPA 70 US or the Canadian Electric Code C22 3 NO 280 13 Canada Attention Pour r duire les risques d incendie de se connecter uniquement un circuit fourni avec le appropri circuit de d rivation protection maximale contre les surintensit s en conformit avec le Code National lectrique ANSI NFPA 70 US ou Code Canadien de l lectricit C22 3 NO 280 13 Canada EV40 Model Circuit Breaker Rating Receptacle Type HCE Modele Calibre de Disjoneteur Prise Electrque EV40 Hardwired 40A n a EV40P NEMA 14 50 plug 50A NEMA 14 50R Caution This is a single phase device Do not connect all 3 phases of a 3 phase feed You may use any two phases of a 3 phase wye connected feed The center point of the 3 phases usually used as Neutral must be grounded somewhere in the system A Neutral connection is not required by the EV40 Charger Only Line 1 Line 2 and Ground are required as shown in Fig 3 Attention II s agit d un appareil monophas Ne pas relier tous les 3 phases d un alimentation triphas e Vous pouvez utiliser les deux phases d un triphas en toile transformateur alimentation Le point central des triphas g n ralement utilis comme neutre doit tre mis la terre quelque part dans le syst me Une connexion neutre n est pas exig e par le EV40 Seulement ligne 1 ligne 2 et Mise a la Terre sont n cessaires comme le montre la Figure 3 Caution The two phases used must eac
23. riod shall commence on the date of installation date first use The product installation date must be evidenced and communicated to Sun Country Highway by way of the warrantee registration card or its equivalent The warrantee registration card must be filled out completely and accurately and returned to Sun Country Highway within 30 days after installation and the product installation date shall be within 6 months after the purchase date If a Product installation date is not communicated to Sun Country Highway as described above the product purchase date shall serve as the warranty commencement date If this product is defective in materials or workmanship during the warranty period Sun Country Highway will at its option repair or replace the product Repair parts and or replacement products may be either new or reconditioned at Sun Country Highway s discretion This limited warranty does not cover service or parts to repair damage due to improper installation or use including but not limited to improper connections with peripherals external electrical faults accident disaster misuse abuse or modifications to the product not approved in writing by Sun Country Highway Any service repair outside the scope of this limited warranty shall be at applicable rates and terms then in effect The warranty covers factory parts and labour only it does not cover field service or removal and replacement of the product or any other costs AII other ex
24. s manual for service information Do not attempt to repair or service the charge station yourself e Do not operate your charge station or the SAE J1772TM charge cable are physically open cracked frayed or otherwise visibly damaged Contact your Service Representative for Page 1 EV40 User s Manual service immediately Refer to the Customer Support section in this manual for information on the Service Representative in your area e Not for use in commercial garages where a COMMERCIAL GARAGE is defined as a facility or portion thereof used for repair of internal combustion vehicles in which the areaway be classified due to flammable vapours being present such as from gasoline e Do not place fingers inside of the coupler end of the SAE J1772TM charge cable e Do not allow children to operate this device Adult supervision is mandatory when children are in proximity to a charge station that is in use Instructions concernant des risques d incendie ou de choc lectrique Lorsque vous utilisation de la EV40 pr cautions fondamentale s curit lectrique doivent tre suivies e Utilisez cette station de charge pour charger les v hicules lectriques quip s d un SAE J1772 port de recharge seulement Consultez le manuel du propri taire du v hicule afin de d terminer si le v hicule est quip d un correcte port de recharge Assurez vous que le SAE J1772TM c ble de recharge sur la station de recharge est positionn d
25. such as alcohol or benzene Avertissement Pour r duire le risque de choc lectrique ou des dommages quipement user de prudence lors du nettoyage de l appareil et le c ble du connecteur de charge EV 1 Eteignez la quipement au disjoncteur avant de le nettoyer 2 Nettoyez votre quipement l aide d un chiffon doux l g rement humidifi avec une solution de d tergent doux Ne jamais utiliser de tampon abrasif de poudre r curer ou de solvants inflammables tels que l alcool ou le benz ne CUSTOMER SUPPORT Call your Service Representative at any time 24 hours a day at the number below PLEASE HAVE THE MODEL NUMBER AND SERIAL NUMBER AVAILABLE WHEN YOU CALL These can be found on the side of the enclosure If your call is made after business hours or on weekends please leave your name telephone number the unit s serial number and a brief description of the problem A Service Representative will call back at the earliest opportunity Please visit Sun Country Highway s Website www suncountryhighway ca Page 16 EV40 User s Manual SPECIFICATIONS Line Input Power Service Entrance Voltage amp Wiring Service Conductors Voltage Range Frequency Current amp Output Power at 240VAC Plugs Dimensions Weight Cable Length Environment Agency Approvals Page 17 240V AC single phase LI L2 and Safety Ground 208V AC 3 phase wye connected Any 2 phases and Safety Ground 240V AC
26. tilation Contact your Service Representative for information Attention NE PAS RECHARGER un v hicule l int rieur si il n cessite une ventilation Contactez votre repr sentant de service pour plus d informations EV40 User s Manual FCC INFORMATION This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This product has been designed to protect against Radio Frequency Interference RFI However there are some instances where high powered radio signals or nearby RF producing equipment such as digital phones RF communications equipment etc could affect operation If interference to your charge station is suspected we suggest the following steps be taken before consulting your Sun Country Highway Sales and Service Representative for assistance 1 Reorient or relocate nearby electrical appliances or equipment during charging 2 Turn off nearby electrical appliances or equipment during charging Caution Changes or modifications to this product by other than an authorized service A facility could void FCC compliance Attention Modifications apport es ce produit par quiconque autre qu un centre de service autoris peut annuler la conformit FCC OPERATION The EV40 Electric Vehicle Charging station is