1. such requests essentially flatten the design hierarchy e Inthe default mode with neither FLAT nor BY CELL specified the polygon output may contain polygons belonging to a cell in two ways o Ifa netin the cell violates ERC Pathchk requirements in some placements of this cell the polygons are written out for each placement where the violation occurs in top level coordinates o If for a given net a violation appears in every placement of a cell the polygons are written out once in the lowest leftmost placement This can lead to confusion because in the same cell some polygons may be displayed in many placements and others in only one placement If the results are difficult to interpret the BY CELL option can be useful The FLAT option can also be used to force Calibre to output cell specific results in all placements This increases both memory consumption and the size of the polygon file but can eliminate potential confusion caused by hierarchical output However output using the NETS option is unambiguous in all cases ERC Pathchk statements are not executed if the specified net is not present For example if there is no power net in the layout then ERC PATHCHK POWER generates an error message and generates no output Results Output Options The output files are readable by RVE similar to a DRC Results Database POLYGONS The POLYGONS option specifies a file named ayout_primary pathchk erc It is placed in the Mask S
2. top level connectivity Text Layer text objects that are power and or ground net labels to be present Possible choices are POWER Reports nets with a path to a power net POWER Reports nets with no path to a power net GROUND Reports nets with a path to a ground net GROUND Reports nets with no path to a ground net Where the exclamation mark is synonymous with Boolean NOT The labeled_flag and the power_ground_flag keywords when not connected by an operand are called primitive conditions e operand An optional string of logical symbols that combine two primitive conditions Possible choices are amp amp Selects nets that satisfy both primitive conditions Boolean AND Select nets that satisfy the first or second primitive condition or both Boolean OR e POLYGONS NETS POLYGONS NETS Specifies the type of results file to output Possible choices are POLYGONS Generates an Calibre nmDRC results database in ASCII format that contains the polygon output of all nets that satisfy the specified conditions NETS Generates a text file that contains a list of all nets that satisfy the specified conditions Both are specified by default e BY LAYER BY CELL FLAT An optional keyword set that specifies the type of output to include in the generated ASCII results file These pertain to the POLYGONS option only Possible choices are BY LAYER Generates a separate check for each l
3. ERC Pathchk Specification statement Reports nets in the layout that do or do not have a path to power ground or labeled nets or that satisfy a combination of these conditions Used during circuit extraction in Calibre nmLVS Calibre nmLVS H and ICtrace Mask mode Note This statement is provided primarily for backward compatibility The Pathchk layer stat conducting ERC checks Usage ERC PATHCHK labeled_flag power_ground_flag operand power_ground_flag POLYGONS NETS POLYGONS NETS BY LAYER BY CELL FLAT PORTS ALSO NOFLOAT EXCLUDE UNUSED EXCLUDE SUPPLY Parameters e labeled_flag A required string that specifies how the tool reports a net that does or does not have a path to a top level labeled net This option requires top level connectivity Text Layer text objects that are neither power nor ground net labels to be present Possible choices are LABELED Reports nets with a path to a labeled Text Layer net LABELED Reports nets with no path to any labeled Text Layer net where the exclamation mark is synonymous with Boolean NOT A labeled_flag may not be specified with a power_ground_flag power_ground_flag A required string that specifies how the tool reports a net that does or does not have a path to a top level supply net Power and ground nets are top level nets specified in the LVS Power Name and LVS Ground Name statement This option requires
4. VDB Directory if that statement is specified otherwise in the current working directory If Jayout_primary is not specified the word lvs is used instead The file consists of lines in the format ERC PATHCHK condition in cell cell_name layer_name where condition is the specified condition such as POWER or POWER amp amp GROUND By default results from each ERC Pathchk statement are written to one check in the result file If the BY CELL option is specified then the results are classified by cell and the ce _name field indicates the cell name If the BY LAYER option is specified then the results are classified by layer and the Jayer_name field indicates the layer Empty checks are not written If all checks are empty no file is created All polygon results are shown in the top level coordinate space and they are written to a Calibre nmDRC results database in ASCII format By default hierarchical Calibre shows cell specific results only once in a representative placement of the cell The lowest leftmost placement of each cell serves as its representative This is similar to Calibre nmDRC H Results are cell specific if they can be generated locally in the cell and occur in all placements of the cell in the design Note that polygon results generated by ERC Pathchk are not fully merged This means that polygons can abut or overlap NETS The NETS option specifies a file named ayout_primary pathchk rep It is placed i
5. XCLUDE SUPPLY An optional keyword that instructs the tool to exclude power and ground nets from the results of an ERC Pathchk request containing at least one of the keywords POWER or GROUND not preceded by the operator Supply nets are included if EXCLUDE SUPPLY is not specified Description Reports nets in the layout that do or do not have a path to top level power and or ground nets or labeled nets By default a path is any route that leads through source drain pins of built in MOS devices or pos neg pins of built in resistor devices To qualify a MOS device types M ME MD MN MP or any of the LDD type devices must have at least the following pins G or gate S or source and D or drain Paths through LDD type devices are formed in both directions Capacitor diode or bipolar devices can also be added to the path as specified in ERC Path Also statements If you want to enable user defined devices to participate in ERC Pathchk user defined devices do not participate by default then you must map these devices and their pins to built in devices and pins This is done using the LVS Device Type specification statement See User Defined Devices in Path Check Operations in the Calibre Verification User s Manual Power and ground nets are specified with LVS Power Name and LVS Ground Name specification statements respectively This statement utilizes wildcard characters that appear in LVS Power Name and LVS Ground N
6. ame specification statements Power and ground nets break paths The hierarchical level from which text objects are read is controlled by the Text Depth statement Power and ground nets are included in the result for the keywords POWER and GROUND For example supply nets are included if you specify ERC PATHCHK POWER You can exclude supply nets by specifying EXCLUDE SUPPLY When specifying EXCLUDE SUPPLY at least one of the POWER or GROUND keywords must also be specified in the statement The EXCLUDE SUPPLY keyword does not apply to the POWER or GROUND keywords For example ERC PATHCHK POWER amp amp GROUND EXCLUDE SUPPLY is allowed However this form causes a compiler error ERC PATHCHK POWER amp amp GROUND EXCLUDE SUPPLY bad syntax Power and ground nets are not included in the result for POWER and GROUND keywords The supply net itself is not selected even if there is no path from power to ground For example ERC PATHCHK GROUND If a net in the design matches more than one of LVS Power Name or LVS Ground Name name patterns a warning is issued and conflicts are resolved with power names being given priority over ground names The LABELED nets are those with connectivity extraction Text Layer text but they are not power or ground nets By default nets that are labeled by port objects alone no Text Layer objects are not output The PORTS ALSO option changes this behavior All objects from n
7. ayer If both BY CELL and BY LAYER are specified a check is generated for each layer in each cell Empty checks are not generated BY CELL Causes each cell that has cell specific results to be checked separately The check contains nets reported in that cell The results are reported in top level coordinate space BY CELL is ignored in flat execution FLAT Causes cell specific results to be replicated in every placement FLAT has no effect in flat execution e PORTS ALSO An optional keyword that specifies to output polygons on nets that are connected only to port objects nets having Text Layer objects on them are not included By default such nets are not included in the output for any request The PORTS ALSO option removes the special treatment of port nets This option affects both POLYGONS and NETS output Note that port objects are specified with the Port Layer Text in Calibre and the make_port command in Pyxis Layout e NOFLOAT An optional keyword that instructs the statement to ignore floating nets Floating nets are nets that are not connected to any devices e EXCLUDE UNUSED An optional keyword that instructs the statement to exclude unused nets from the ERC Pathchk output Unused nets are connected only to unused devices Unused devices are specified with LVS Filter Unused Option or equivalent LVS Filter Unused statements All options for LVS Filter Unused Option are supported except the INV P and Q options e E
8. ets connected to top level nets named by port objects alone are output ERC Pathchk statements respect the LVS Compare Case statement If either the LVS Compare Case YES or LVS Compare Case NAMES statement is specified then power names and ground names are traced in a case sensitive manner otherwise they are case insensitive These rules on case sensitivity apply to LVS Power Name and LVS Ground Name nets ERC Pathchk observes the Layout Preserve Case specification statement for case sensitivity of net names See Case Sensitivity of Supply Net Names in the Calibre Verification User s Manual for more details This statement applies to Calibre nmLVS Calibre nmLVS H and ICtrace Mask mode It is executed during circuit extraction and only when the layout is geometric The following Calibre commands execute this statement calibre lvs rules executed flat calibre lvs tl rules executed flat calibre lvs hier rules executed hierarchically with geometric Layout System calibre spice rules The following Pyxis Layout commands execute this statement Slvs_mask executed flat Swrite_mask_cnet executed flat Note the following important considerations e The POWER GROUND and LABELED options without the operator are not recommended because they can generate very large files consume large amounts of memory and lead to long runtimes In particular in hierarchical ERC
9. n Calibre issues the warning in both the transcript and the circuit extraction report This limit applies only to polygon output for example during the construction of a result layer and when performing the POLYGONS option Calibre always completes the net reporting part of this functionality including the functionality resulting from the NETS option You should not reach this limit in normal operations You see it only in circumstances when a very large net is selected by the ERC Pathchk statement See also ERC Summary Report The search features Find Path and Isolate Path on Layout Net in Calibre RVE for LVS may also be of interest Examples Example 1 The following statement outputs a text file listing all the nets with a path to a labeled net ERC PATHCHK LABELED NETS Example 2 When not using the LABELED option the following combinations are possible POWER amp amp GROUND Nets with no path to power but with a path to ground GROUND amp amp POWER Nets with no path to ground but with a path to power GROUND amp amp POWER Nets with no path to ground and no path to power GROUND POWER Nets with no path to ground or no path to power or both POWER amp amp GROUND Nets with a path to both power and ground POWER GROUND Nets with path to power or a path to ground
10. n the SVDB directory by default otherwise in the current working directory Iflayout_primary is not specified the word lvs is used instead In hierarchical execution the report file format is this ERC PATHCHK REPORT for layout_primary ERC PATHCHK condition cell cell_name placement netl net2 cell cell_name placement netl net2 where condition is the specified condition such as GROUND AND POWER cell_name is a cell name where results were found placement is a representative placement of that cell and net is a net name or number Cells are listed in bottom up order Net names and numbers are in the context of the indicated cells Cells for which no nets are found by ERC Pathchk are not written to the report file In flat execution the report file format is ERC PATHCHK REPORT for layout_primary ERC PATHCHK condition netl net2 Nothing is reported for requests in which no nets are found in any cell If all checks are empty no file is created Requirements and Restrictions Hierarchical Calibre operations impose a size limit on intermediate data structures generated by ERC Pathchk The limit is approximately 400 MB This limit is applied independently to each individual ERC Pathchk statement Calibre generates incomplete results some polygons may be omitted from the output and issues the following warning if Calibre reaches this limit WARNING ERC operation exhausted allowed memory allocatio

Download Pdf Manuals

image

Related Search

Related Contents

Questionnaire de Sensibilisation au Bon Usage des AVK dans les  株式会社 キクチ科学研究所 スプリングローラー型スクリーン 外観詳細図 SBSR  取扱説明書 MD(669KB  Manuale tecnico  Catálogo Instrumentos de medición de pH testo  Operating Instructions Spare Parts List  Philips LX9000R/25S Home Theater System User Manual  agendaculturel - Mairie d`Aix-en  Samsung Galaxy Tab (10.1) User Manual  SkyLink EQ User's Manual  