1. Installation Environment For details of the installation environment refer to the user s manual of the MELSEC Q series CPU module to be used Incorrect correctly No short bar installed Short circuit between 12V and 24V Short circuit between 5V and 12V 5 3 Procedure Open the cover EE CAUTION Set the setting pins short bar as necessary Insert the short bar all the way into the setting pins in place till it can not be moved Make sure they have been set correctly and close the cover Hold the protective wrap with its rear side towards the right and peel it off towards yourself before installing a MELSEC AnS Series terminal block Protective wrap 7 External Dimensions Unit mm rel i 6 Part Names and Installation Method Installation with the Base Adapter To the control panel Base Adapter gt Mounting bracket supplied with Conversion Adapter MELSEC Q Series Base Unit Mounting bracket fixing screw M2 6 x 4 supplied with Conversion Adapter MELSEC AnS Series terminal block Precaution MELSEC AnS Series terminal block cover supplied with Conversion Adapter MELSEC Q Series Module Fixture has been installed to the Conversion Adapter MELSEC AnS Series terminal block in
2. Wiring Precautions nia Mitsubishi General Purpose Programmable Controller CAUTION 3 Product Specifications For detail specifications which do not appear in the specification comparison charts contained herein see the user s manual supplied with the MELSEC Q Series module you use Those parts of the specification that R l T l differ between the MELSEC AnS Series and the MELSEC Q Series are where a switch from the first series to the second is subjected to specification related restrictions Check the specification of the devices to be enewal 100 es F Carry out wiring for the Conversion Adapter correctly after checking the specification and connected for more details terminal arrangement for the module used Connecting a power supply with a different voltage Furthermore it is recommended to refer to the Transition from MELSEC AnS
3. Products are used in any environment beyond the bounds of the general Quantity specification electric shock fire malfunction or damage to or degradation of the Products Counter Sus gt le 1004s gt le 142us y je 2 8 y bus lg 10us yi le 100 us gt Minimum count pulse width will result Conversion Adapter 1 i 0 dus j 14S 5y 5u 5us j 54S 50us 50458 5 ded P dia ro haa E j Mounting bracket 1 Duty ratio 307 EELSES P u SE B S Pa 4 14 MS eS lt gt i IK mid gt ofan ti irectly ouen Te ck ucive parts of Conversion Adapter Contact will cause Mounting bracket fixing screw M2 6x4 2 1 phase and 2 phase P Min phase differential for Min phase differential for Min phase differential for Min phase differential for matrunction or failure in the system Fixture installation screw M3x8 1 inputs 1 phase input 2 phase input 2 phase input 0 5 us 2 phase input 1 25 us 2 phase input 2 5 us 2 phase input 25 us Fasten the Conversion Adapter and the Mounting Bracket securely with retaining screws Terminal block cover 1 lt 3 pi bi ware z and tighten the screws by applying torque within specified limits Loose screws can lead to Short bar spare parts 1 Coincidence Comparison range 24 bit binary S i T S uzg i 5 i s2 bi singed binary the dropping of the Conversion Adapter or Mounting Bracket p
4. QnAS Small Type Series to Q Series Handbook Intelligent Function Modules L NA 08220ENG issued by Mitsubishi Electric Conversion Adapter ee Conversion Adapter MELSEC AnS Series No of MELSEC Q Series Conversion Model Tighten the MELSEC AnS Series terminal installation screws and terminal screw securely by Model Model channels Model Weight 9 applying torque within the specified limits Loose screws will cause short circuit fire or GN ERNT ASQTD62 D malfunction Excessive tightening will damage the screws or the Conversion Adapter which in ERNT ASQTD62D A1SD62D 2 channels QD62D 110 turn will cause dropping of parts short circuit or malfunction Use care to prevent foreign materials including cuttings and wiring debris from entering the 3 Conversion Adapter or the MELSEC Q Series Module These will be cause for fire failure or Internal circuit diagram of ERNT ASQTD62D User S Manual malfunction Terminal Signal Name Terminal Signal Name Precautions for wiring No No TB1 Phase A A20 Phase A i A A Startup and Maintenance Precautions TBZ Phase A B20 Phase A ED Set the pingjoi each signal GE GED according tojine input voltage Aisnen n e chase S5 Phasa B The default input voltage for all signals is 24v BY side Z N WARNING Terminai Bock Tes 1 PRS SV R PRST 24V Input set to BZ side TBT TB6 CTRL COM B18 u PRST_12V nae aD 2v ide _50CM D180123 C 1409 Do not touch live terminals There is a danger of electric shock or malfunct
5. EE shall repair the product free of charge via the distributor from whom you made your purchase I Gratis Warranty Period The gratis warranty period of this product shall be one 1 year from the date of purchase or delivery to the designated place Note that after manufacture and shipment from MEE the maximum distribution period shall be six 6 months and the gratis warranty period after manufacturing shall be limited to eighteen 18 months In addition the gratis warranty period for repaired products shall not exceed the gratis warranty period established prior to repair i Gratis Warranty Range The gratis warranty range shall be limited to normal use based on the usage conditions methods and environment etc defined by the terms and precautions etc given in the instruction manual user s manual and caution labels on the product Warranty Period after Discontinuation of Production 1 MEE shall offer product repair services fee applied for seven 7 years after production of the product has been discontinued Discontinuation of production shall be reported via distributors 2 Product supply including spare parts is not possible after production has been discontinued Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability Regardless of the gratis warranty period MEE shall not be liable for compensation for damages arising from causes not attributable to MEE opportunity losses or lost profits in
6. ay lead to breakage Operating ambient 1 Counting speed is affected by pulse rise and fall time Possible counting speeds are shown in the following table Note that if a pulse that has a large rise and or fall time is counted a miscount may occur Counting speed switch settings Rise fall time 500k 200k 100k 10k t 0 5us or less 500kPPS 200kPPS 100kPPS 10kPPS humidity Storage ambient humidity 5 to 95 RH non condensing Wiring Precautions Both 1 phase and 2 phase input Before attempting to install the Unit or carry out the necessary wiring make certain that the external power supply used in the system is shut off on all three phases Failure to do so may result in electric shock or damage to the product Constant Half Sweep acceleration amplitude count Vibration Compliant with Bem Sto B 4tiz Samm 10 times each in rasictince JIS B 3502 and vibration 8 4 to 150Hz 9 8m s X Y Z directions IEC 61131 2 Under 5 to 8 4Hz continuous vibration Shock resistance Compliant with JIS B 3502 and IEC 61131 2 147 m s 3 times each in 3 directions X Y Z Operating atmosphere No corrosive gases Precautions for the program Operating altitude 1 0 to 2000m Frequency t 1 25us or less 200kPPS 200kPPS 100kPPS 10kPPS t 2 5us or less 100kPPS 100kPPS 10kPPS t 25us or less 10kPPS 10kPPS t 500us a 500PPS After installation and wiring close the terminal
7. block cover before turning on the module for operation Failure to do so may result in electric shock 8 4 to 150Hz 4 9m s 1 A1SD62D and QD62D differ from each other in the way input output signals X Y and buffer memory addresses are allocated Therefore you need make necessary changes to the sequence program that is Overvoltage category 2 Il or less used f p f 3 2 P lt 3 i 5 Pollution degree 3 2 2 Set the counting speed using the intelligent function module switch setting in the QD62D instead of the setting pins that are used in the A1SD62D 1 Do not use or store under pressure higher than the atmospheric pressure of altitude Om 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities 3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally Installation location Inside a control panel 4 4 1 1 2 3 4 5 6 7 Mounting and Installation Handling Precautions Before attempting to install the Unit or carry out
8. ch is one of the EU Directives has been a legal obligation z ificati z Note that failure to observe the A CAUTION level instructions may lead to a serious consequence for the products sold in European countries since 1996 as well as the Low Voltage Directive since peciticaton comparison according to the circumstances Always follow the precautions of both levels because they are 1997 S Mode MELSEC AnS Series MELSEC Q Series important to personal safety Manufacturers who recognize their products are compliant to the EMC and Low Voltage Specification A1SD62D QD62D Please keep this manual in an easy to access location for future reference and be sure to provide the Directives are required to declare that print a CE mark on their products Switch with the setting pins Switch with the intelligent function module switch setting manual to the end user g Counting speed switch settings 500k 200k 100k 10k Authorized representative in Europe 200k bus 200k to 500kPPS 100k to 200kPPS 10k to 100kPPS 10kPPS or less Precautions before using Authorized representative in Europe is shown below Number of channels 2 channels l Name Mitsubishi Electric Europe BV 4 ph input 1 phase input 1 multiple 2 multiples CAUTION Address Gothaer Strasse 8 40880 Ratingen Germany Phase ap asa npa 2 phase input 1 multiple 2 multiples 4 multiples i p P pl p ples Count input 2 phase input aigna CW CCW input When making a switch from the MELSEC AnS Seri
9. curred by the user due to Failures of MEE products damages or secondary damages arising from special circumstances whether foreseen or unforeseen by MEE compensation for accidents compensation for damages to products other than MEE products or compensation for other work carried out by the user Changes in Product Specifications The specifications given in the catalogs manuals and technical documents are subject to change without notice This document is a new publication effective September 2014 Specifications are subject to change without notice Developed September 2014 50CM D180123 C
10. er and Mounting Bracket or do not give a strong impact to it This will cause damage 4 2 Use Precautions Item Use Precautions Width dimension of Because the module is reduced in width dimension 34 5mm 27 4mm and module thus in area available for wiring check dimensional data before installing the module lt MELSEC AnS Series gt lt MELSEC Q Series gt 34 5mm 27 4mm Depth and Height dimension Installation with the Base Adapter Because the module is increased in depth dimension check dimensional data before installing the module MELSEC AnS Series MELSEC Q Series Ry Conversion Adapter D m bR bi bk bk me bie Mn Rb Base Adapter 110mm J 157 5mm EZ 47 5mmUP Rp 5 Preparation before Installation 5 1 Position of the setting pins Open the cover of the Conversion Adapter and you will find the setting pins to switch the input signal voltage Cover Setting pin e A CAUTION Ww 4 With the cover closed Protective wrap BO A Display nameplate Make sure to set the setting pins short bar before installation Setting pin With the cover opened go x CAUTION ze I A Protective wrap Short bar Description Set the input voltage for Preset in
11. es to the MELSEC Q Series be sure to Signal level 2 i 7 i consult user s manual supplied with individual module under the MELSEC Q Series to 1 Overview GA OB EIA Standard RS 422 A Differential type line driver level AM26LS31 manufactured by Texas Instruments or equivalent a differences in various aspects including performance and function between the two This manual provides information about the Conversion Adapter ERNT ASQTD62D available as Counting 1 phase 200kPPS 10kPPS Renewal Tools for the Mitsubishi General Purpose Programmable Controller speed input 500kPPS 1 200kPPS 1 100kPPS 1 10kPPS 4 The Conversion Adapter is a product for effecting conversion to transcend difference in pin assignment max 2 phase 200kPPS 7kPPS between the MELSEC AnS Series and the MELSEC Q Series input Installation Precautions Before attempting to make a switch from MELSEC AnS Series to MELSEC Q Series in your installation Counting range 24 bit binary 0 to 16777215 32 bit singed binary 2147483648 to 2147483647 Model UP DOWN Preset counter Ring counter function consult the user s manual supplied with individual module under the latter series to learn about how A CAUTION they differ in various aspects including performance and function Use the Conversion Adapter in the environmental conditions that are specified in the general Once you have opened the packaging verify that it contains the following products specification If the
12. ing off state or tilting state will damage the Conversion Adapter installation screws and the mounting bracket a Secure the fixture to the Base Adapter or Conversion Adapter DIN rail mounting bracket bottom of the Conversion Adapter with fixture installation screws M3 x 8 1 place Secure the MELSEC AnS Series terminal block to the Conversion Adapter with the supplied attaching screws M4 2 places top and bottom Remove the terminal block cover from the MELSEC AnS Series terminal block and fit the terminal block cover supplied with the Conversion Adaptor in place 6 2 Tightening Torque Tighten the module installation screws to the specified torque below An inappropriate tightening torque could cause the product to fall or result in a short circuit product failure or malfunction Tightening Torque Range Mounting bracket fixing screw M2 6x4 0 20 to 0 29N m Conversion Adapter installation screw M320 0 43 to 0 57N m Fixture installation screw M38 0 61 to 0 82N m MELSEC AnS Series terminal block installation screw M4 screw 0 78 to 1 18N m Please confirm the following product warranty details prior to product use Gratis Warranty Terms and Gratis Warranty Range If any fault or defect hereinafter referred to as Failure attributable to Mitsubishi Electric Engineering Company Limited hereinafter referred to as MEE should occur within the gratis warranty period M
13. ion 14 TB3 ee ne AN 1 PRST coy apb DUE Se S TBS 5V Input set to RY sid Shut off the external power supply for the system in all phases before cleaning or retightening 1 TB7 TBO Phase A A16 FUNG 24V Connector r PO SS SV ee i 5 h A 5 TBO TB10 c Phase B B16 FUNC 12V Inputting a voltage higher than the one set using the setting pins may cause a failure in the the terminal screws Failure to do so may result in electric shock or cause the MELSEC Q TB hai TB11 H Phase B A15 FUNC 5V B20 o o A20 MELSEC Q Series module EA MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED Series module to fail or malfunction Loose screws can lead to dropping shorting and TB12 513 TB12 2 PRST 5 12 24V i H B15 FUNC COM B19 o o A19 HEAD OFFICE Hulic KUDAN BLDG 1 13 5 KUDANKITA CHIYODA KU TOKYO 102 0073 JAPAN malfunction Excessive tightness of the screws can lead to breakage of the screws Conversion Liz TB15 TB13 CTRL COM H_AT4 Phase A B18 0 o A18 NAGOYA ENGINEERING OFFICE 139 SHIMOYASHIKICHO SHIMOYASHIKI KASUGAI AICHI 486 0906 JAPAN Adapter Mounting Bracket or MELSEC Q Series Module possibly causing the dropping Te18 E7 TEA FUNES ARA is EhaseA B17 0 0 AIT shorting and malfunction thereof TB20 TB16 EQU2 i T BT Phase B B15 o o A15 TB17 EQUT Ai2_ PRST 24V B14 0 o A14 TB18 2 EQU2 B12 PRST 12V B13 0 o A13 SAFETY PRECAUTIONS TB19 12 24V A11 PRST_5V B12 o o A12 TB20 ov BTI PRST COM B11 o o A11 Always read the
14. ossibly causing breakage output Comparison result et value lt Count value Set value Count value Set value gt Count value thereof Excessive tightness of the screws can lead to breakage of the screws Conversion Eternal input Preset 5 12 24VDC 5 12 24VDC 2 to 5mA Adapter Mounting Bracket or MELSEC Q Series Module possibly causing the dropping 2 General S eci ications Function start 2 to 5mA EIA Standard RS 422 A Differential Line Driver may be connected shorting and malfunction thereof p iat oe Transistor sinking type output 12 24VDC_ 0 5A point 2A common Always check for correct match between MELSEC Q Series and the Conversion Adapter p z z p z z PEET O occupied points 32 points 16 points Incorrect match can cause damage to the MELSEC Q Series Module Item Specifications i j i i Wiring connection system 20 point terminal block 40 pin connector When installing the Conversion Adapter take care not to get your hand snagged on the Operating ambient 0 to 55 C Maximum surrounding air temperature 55 C Internal current consumption 5VDC 0 25A 0 38A Mounting Bracket or the like Injury may result temperature St bient a i ificati i i i i When installing or removing the MELSEC Q Series Module complete with a Converter P an 25 to 75 C Make sure the section of the above table meets the specification of the machines and equipment connected to the MELSEC Q Series module Adapter be sure to hold it with both hands Dropping m
15. put of CH1 Factory setting Set the input voltage for Function start input of CH1 Set the input voltage for Preset input of CH2 24V About the protective wrap It is used to protect your hands from touching the conductive part in the pin setting process 1 Peel it off after finishing the settings Set the input voltage for Function start input of CH2 2 Make sure to peel it off before installing a MELSEC AnS Series terminal block Voltage Signal 5 2 How to set the setting pins Set the input voltage for each signal using the short bar The short bar can be installed from any direction 24V Factory setting Installation with the DIN rail 4 3 Because the module is increased in depth and height dimension check dimensional data before installing the module MELSEC AnS ares MELSEC Q Series 4mm ti Conversion Adapter Conversion Adapter DIN rail mounting bracket 106mm j Meili Lae 150 5mm L 44 5mmUP Terminal block The terminal block cover for MELSEC AnS Series is bigger than the width of cover the MELSEC Q Series Module Therefore it is necessary to replace it with the terminal block cover supplied with the converter adapter lt MELSEC AnS Series gt lt MELSEC Q Series gt Terminal block cover for the MELSEC AnS Series Replace the terminal block cover with the lone supplied with the Conversion Adapter
16. se precautions prior to use A CAUTION AT ane av oo oo TN oo Do not modify the Conversion Adapter or take it apart Doing so will cause failure Ae aS oo pg 5 2 n Before using this product please read this manual carefully and pay full attention to safety to ensure malfunction personal injury or fire 7 Open Be oo m en that the product is used correctly Do not drop the Conversion Adapter and Mounting Bracket or do not give a strong impact to AT Open py cc las The precautions presented in this manual are concerned with this product only For Programmable it This will cause damage B7 Open B3 o 0 A3 Controller system safety precautions refer to the user s manual of the MELSEC Q series CPU A6 c EQU1 B2 o o A2 B6 1 EQU2 B1 o o A1 module to be used g 55 c EaU E In this manual the safety precautions are ranked as WARNING and CAUTION Disposal Precautions B5 J EQU2 e e e e e e e e e e e e e e e e i o o o e o O u CAUTION A4 Open A B4 Open l WARNING Indicates that incorrect handling may cause hazardous conditions l e Open E a an pen l resulting in death or severe injury l When disposing of the product treat it as industrial waste A2 ov AN B2 12 24V i i i iti Al ov I A CAUTION Indicates hat incorrect handling may cause hazardous conditions Bi TOAN resulting in medium or minor injury and or property damage I EMC AND LOW VOLTAGE DIRECTIVES Ve 27 Compliance to the EMC Directive whi
17. stallation screw M4 Fixture installation screw M3 x8 supplied with Conversion Adapter Conversion Adapter installation screw M3 x 20 Conversion Adapter Make sure to set the setting pins before installation Installation with the DIN rail DIN rail Xx Conversion Adapter DIN rail mounting bracket right Mounting bracket supplied with Conversion Adapter MELSEC Q Series Base Unit Mounting bracket fixing screw M2 6 x 4 supplied with Conversion Adapter 7 steife MELSEC AnS Series terminal block MELSEC AnS Series terminal block cover supplied with Conversion Adapter X MELSEC Q Series Module Conversion Adapter DIN rail mounting bracket bottom Fixture has been installed to the Conversion Adapter Fixture installation screw M3 x 8 MELSEC AnS Series terminal block installation screw M4 102 27 4 A Mounting bracket Terminal block cover oF v A 2 N 3 oO 4 N 5 YY 6 TE z iS N j Al g Or v M KY Cc DI ES 17 55 supplied with Conversion Adapter Conversion Adapter installation screw M3 x 20 XThe separatel
18. the necessary wiring make certain that the external power supply used in the system is shut off on all three phases Failure to do so may result in electric shock or damage to the product Do not touch live terminals There is a danger of electric shock or malfunction Do not modify the Conversion Adapter or take it apart Doing so will cause failure malfunction personal injury or fire Do not touch the energized part of the Conversion Adaptor directly Contact will cause malfunction or failure in the system The protective wrap is used to protect your hands from touching the conductive part in the pin setting process Peel it off after finishing the settings In addition make sure to peel it off before installing a MELSEC AnS Series terminal block Fasten the Conversion Adapter and the Mounting bracket securely with retaining screws and tighten the screws by applying torque within specified limits Loose screws can lead to the dropping of the Conversion Adapter or Mounting bracket possibly causing breakage thereof Excessive tightness of the screws can lead to breakage of the screws Converter Adapter Mounting bracket or MELSEC Q Series Module possibly causing the dropping shorting and malfunction thereof Use care to prevent foreign materials including cuttings and wiring debris from entering the Conversion Adapter or the MELSEC Q Series Module These will be cause for fire failure or malfunction 8 Do not drop the Conversion Adapt
19. y sold Conversion adapter Conversion Adapter DIN rail mounting bracket ERNT ASQDIN is required to use this Conversion Adapter Refer to the user s manual of the DIN rail mounting bracket of the Conversion Adapter for the installation method 6 1 Installation Method Make sure to set the setting pins before installation Installation with the Base Adapter Installation with the DIN rail Mount the MELSEC Q Series Base Unit to the Base Adapter Refer to the Base Adapter s manual for how to install them to the control panel Mount the MELSEC Q Series Base Unit to the DIN rail mounting bracket of the Conversion Adapter and the adapters for DIN rail installation manufactured by Mitsubishi Electric For how to mount them to the DIN rail refer to the user s manual of the Conversion Adapter DIN rail mounting bracket and QCPU Product Warranty Details v v Mount the MELSEC Q Series module to the MELSEC Q Series Base Unit Secure the Mounting Bracket to a compatible module under the MELSEC Q Series with Mounting Bracket fixing screws M2 6 x 4 2 places Install the Conversion Adapter to the MELSEC Q Series module and secure it with the Conversion Adapter installation screws M3x20 2 places Precaution Before tightening the installation screws check that the Conversion Adapter has been securely installed on the MELSEC Q Series module Tightening the screws in float