1. WARNINGS CONT You should not operate a vehicle or heavy machinery while using the Game Ready System To avoid the risk of electrical shock do not remove any panels from the Control Unit Refer all servicing and repair to Game Ready Customer Service at 1 888 426 3732 Opening the case will void the Game Ready warranty Never operate the System with damaged power line cords or connector hoses Always turn off the System and disconnect the power line cord from its electrical outlet when not in use or before adding ice and water Do not use any adapter other than that provided by Game Ready Use of other adapters may result in electrical shock and will void the Game Ready warranty Be careful not to trip over the System s power cords and connector hose Be mindful of the power cords and connector hoses to avoid any risk of strangulation PRECAUTIONS Do not operate the System without any water in the ice box Do not pour hot water into the ice box Do not pick up the Control Unit by the lid Carry using the handle only Do not use any wraps designed by other manufacturers with the Game Ready System The Game Ready Control Unit is a technical medical device Handle it with the same care as you would a laptop computer Do not drop it kick it or otherwise abuse it unnecessarily Such abuse will void all Game Ready warranties In addition to the precautions listed above additional warnings and safety precautions are posted through
2. POWER SUPPLY DISCLAIMER Mains power quality should be that of a typical commercial or hospital environment Surge protection is recommended to protect the Control Unit If the user of the Game Ready System requires continued operation during power mains interruptions it is recommended that the Game Ready System be powered from a uninterruptible power supply PRODUCT SPECIFICATIONS Size 400mm width x132mm height x 210mm depth 15 75 in x 5 2 in x 8 27 in not including carrying case Weight 8lbs empty 18lbs full of ice amp water Pressure level Cycles from 5mm Hg up to 75mm Hg AC power 100V 240V 50 60 Hz 1 0 A DC input 12V 2 5 A HOW TO CONTACT US Game Ready Phone numbers Customer Service Department 1 888 GameReady 1201 Marina Village Pkwy Ste 200 1 888 426 3732 Alameda CA 94501 510 868 2100 1 510 559 3940 www gameready com Game Ready Control Unit User s Manual PN 703607 Rev L
3. Changing Timer During Treatment To add or subtract minutes while the timer is running you must first press pause then press the plus or minus buttons If you press the timer setting button or the plus or minus buttons while the system is in use the system will not respond Running The System Continuously If you d rather run the system continuously just press the timer button once the display will change to zero and the hourglass icon will disappear Press start and the system will run and begin counting elapsed time The system will run for a maximum of 190 minutes by counting up to 95 minutes and then back down to zero After 190 minutes the system will stop and remain in pause mode OPERATING THE SYSTEM IN THE BAG To operate the Game Ready System you don t need to remove it from the bag Simply unzip the bag s main compartment and end panel To fill with ice and water open the ice box lid Attach the Connector Hose and the AC adapter to the end panel of the Control Unit Plug the AC adapter into an electrical outlet When finished with the therapy session unplug the AC adapter from the electrical outlet Disconnect the Connector Hose and the AC adapter from the end panel of the Control Unit Remove the Control Unit from the bag to empty the ice box POWERING THE SYSTEM How to Use the AC Adapter The Game Ready System operates using external power through the AC adapter Connect the AC adapter to the Control Unit an
4. the Timer button to select an alternate program or to access Manual Mode where you can adjust pressure and time settings Warning The Cooling Vest should only be operated on no pressure or low pressure Do not operate the Cooling Vest on medium or high pressure Changing Pressure During Treatment The pressure cannot be adjusted while the system is in use To adjust the pressure press the pause button change the pressure to the desired mode and then press the start button to resume therapy ADJUSTING TEMPERATURE Press the C F button to choose your desired mode By turning the temperature knob you can adjust the amount of ice water being pumped through the Wrap Turn the knob towards the three snowflakes for colder or towards the one snowflake for warmer With a full ice box typically the Control Unit will provide cold therapy between 35 F and 50 F SETTING TREATMENT TIME Each time the power button is used to turn the system on the hourglass icon will appear and the timer will automatically set for 15 minutes If you press start the system will run for 15 minutes then stop Adjust the length of a timed session by pressing the plus or minus keys to your desired time from 0 95 minutes in 5 minute increments Once you ve set the desired treatment time press the start button An hourglass icon will appear on the control panel to indicate the timer is running When the time is up the alarm will beep and the system will stop
5. turns off during use If the system current draw rises above 1 99 amps during operation the Control Unit will shut off to prevent damage to the pumps Usually this is an indicator of a blockage in the fluid or air flow Check the Wrap and the Connector Hose to be sure there are no kinks creases or folds Unplug the Control Unit to reset the system and try the Wrap again If the Control Unit shuts off again there is either a problem with the Wrap or the Control Unit Try a different Wrap to determine if it is the Control Unit or the Wrap and call Game Ready customer service at 1 888 GameReady for further assistance Control unit leaks water when placed on its side 1 If the Control Unit is on its side check to be sure that the control panel is not upside down The unit is not designed to rest this way and doing so will cause water to leak through its air vent While a minimal amount of water leakage should not damage the system immediately place the unit in its proper position upright or on its side with the rubber feet facing down 2 If there is excess water on the rubber gasket around the mouth of the ice box the lid will not seal properly and some of the water is likely to drip out when placed on its side Simply wipe off excess water from the gasket and close the lid securely 3 Check the ice box gasket to be sure it s seated properly around the lip of the ice box If it is not flat in the groove push it down so that it is flush
6. 30 Low Pressure KWE 30 30 Med Pressure EN 12 EN 13 ADJUSTING SYSTEM SETTINGS ADJUSTING PRESSURE Press the pressure button on the control panel to adjust the level of compression The system has four pressure options 1 No pressure circulates the ice water only 2 Low pressure inflates and deflates the Wrap from 5 15 mm Hg over approximately a 5 minute cycle 3 Medium pressure inflates and deflates the Wrap from 5 50 mm Hg over approximately a 3 minute cycle or 4 High pressure inflates and deflates the Wrap from 5 75 mm Hg over approximately a 3 minute cycle The appropriate pressure icon will flash as the unit cycles pressure The left hand side of the icon will appear and flash as the pressure cycles up and then the right hand side will appear and flash as the pressure cycles down Large Wraps such as the Knee Wrap will have longer pressure cycles than smaller Wraps such as the Ankle The system will default to the low pressure mode for all Wraps To adjust the pressure press once for medium pressure twice for high pressure and three times for no pressure If you press pause for any reason such as to switch Wraps the pressure will remain in its previously selected mode until you press the pressure setting button to adjust Only by turning the system off will it reset to the default pressure mode Note If you have a Pre Programmed Unit the system will default to Pre Set Program 1 no compression You can press
7. 6 EN 7 CONTROL PANEL BASIC CONTROLS Pressure display Temperature display Green indicates unit has power Second tick marks Temperature knob Power on off Celsius Fahrenheit Timer on Alarm silencer Start pause Decrease time Pressure setting Increase time Timer setting PRIMING A NEW WRAP OR COOLING VEST A brand new Wrap or Cooling Vest should first be filled with water primed before it is used To prime a new Wrap or Vest follow the Quick Set Up Instructions and then the following 1 Connect Wrap or Vest to Control Unit Wrap or Vest need not be worn to prime 2 Press the pressure button on the control panel to set the pressure on no pressure 3 Turn the temperature control knob to maximum cold 3 snowflakes 4 Press the start button 5 Run for a minimum of two minutes Note Often when priming a larger Wrap or vest the Control Unit alarm will sound after 45 seconds the low flow icon will flash and the Control Unit will stop This is because there isn t enough water returning to the Control Unit due to the new Wrap being filled To continue simply restart the priming process following the steps above After 2 minutes the Wrap or Vest is fully primed and ready to be used Repeat the steps above for each additional new Wrap or Vest CONTROL UNIT SET UP Filling the Ice Box Stand unit upright Then unplug the unit from the electrical outlet To open the ice
8. GAME Q G READ Y CONTROL UNIT User s Manual MODEL 500055 GAME READY CONTROL UNIT MODEL 550350 PRE PROGRAMMED CONTROL UNIT THE GAME READY DIFFERENCE Game Ready was built upon the concept that the principles behind spacesuit technology could be used to develop an injury treatment system As a designer for NASA and an inductee into the U S Space Foundation s Hall of Fame our founder helped pioneer the technology involved in controlling pressure and temperature within a flexible garment In 1998 we began working with athletes athletic trainers doctors and engineers to expand breakthrough discoveries into the realm of sports medicine INDICATIONS FOR USE The Game Ready System combines cold and compression therapies It is intended to treat post surgical and acute injuries to reduce edema swelling and pain where cold and compression are indicated It is intended to be used by or on the order of healthcare professionals in hospitals outpatient clinics athletic training settings or home settings REGISTER YOUR PRODUCT Please complete and return the Warranty Registration cards for both the Game Ready Control Unit and the Wraps The Control Unit registration card is located behind the front cover of this manual and the Wrap registration card is packaged with the heat exchanger of each Wrap You may also go to www gameready com to register your product You must register within 30 days from the date of purchase in order to rece
9. L EXPRESS AND IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD NO WARRANTIES APPLY AFTER THAT PERIOD SOME JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THIS LIMITATION MAY NOT APPLY TO YOU LIMITATIONS OF LIABILITY COOLSYSTEMS RESPONSIBILITY UNDER THIS OR ANY OTHER WARRANTY IMPLIED OR EXPRESS IS LIMITED TO REPAIR OR REPLACEMENT AS SET FORTH ABOVE THESE REMEDIES ARE THE SOLE AND EXCLUSIVE REMEDIES FOR ANY BREACH OF WARRANTY COOLSYSTEMS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR UNDER ANY OTHER LEGAL THEORY INCLUDING BUT NOT LIMITED TO LOST PROFITS DOWNTIME GOODWILL AND DAMAGE TO OR REPLACEMENT OF EQUIPMENT AND PROPERTY SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM JURISDICTION TO JURISDICTION How to Complete the Warranty Registration Card You will need the following information to complete your registration card The Control Unit s model number and its serial number These numbers are located on the label on the bottom of the Control Unit EN 20 USER REPLACEABLE ITEMS The items listed below can be obtained by calling toll free 1 888 GameReady Filter Silicone spray
10. Low Pressure ENAN 30 30 Med Pressure If you press the timer button once you will be in Pre Set Program 2 and if you press the timer button twice you will be in Pre Set Program 3 Please Note If you press the timer button three times you will be in Manual Mode The Control Unit will be set for a 15 minute treatment at low compression You can select the pressure and time settings to adjust your treatment Press the timer button once more to toggle through the elapsed time setting One more press of the timer button will bring you back to Pre Set Program 1 7 Start with the temperature knob turned to maximum cold 3 Snowflakes Adjust the temperature as necessary Select pressure and time settings 8 Press the Start button CONTROL PANEL Pressure display Green indicates unit has power Power on off Temperature display Second tick marks Temperature knob TIMER PRESSURE OROM Timer on Start pause Decrease time Timer setting Celsius Fahrenheit Alarm silencer Pressure setting Increase time PRESSURE SETTINGS No pressure 5 15 mmHg Medium 5 50 mmHg PRE SET PROGRAM DISPLAY For Pre Programmed Control Units Only Pressure Display rawas Low 5 15 mmHg f f f Med 5 50 mmHg NNN High 5 75 mmHg Treatment Time Sleep Time between Treatments amp Temperature in Use Program Indicator 30 30 No Pressure IS 30
11. and therefore remains attached to the inside of the unit 7 Clean the filter by rinsing it thoroughly under warm running water Shake it a few times to clear out any remaining debris 8 Re insert the filter in the unit by reaching in and snapping it back into the housing You should hear it click into place Wrap Care See Wrap Use Guide for instructions on how to clean the exterior of the Wraps The interior of the Wrap can be cleaned once a month by emptying 2 3 bottles of 16 24 oz hydrogen peroxide 2 into the ice box of the Control Unit and running the system for five minutes Fill the ice box approximately four inches deep with hydrogen peroxide Leave the ice box lid open Adjust the pressure setting to the no pressure mode Adjust the temperature to its coldest setting 3 snowflakes Set the timer for five minutes and press the start button Caution Leave the ice box lid open when using hydrogen peroxide to clean the interior of the wrap If the ice box is sealed shut hydrogen peroxide can form a gas that could build excess pressure inside the unit and potentially damage the system Wrap Storage Do not store Wraps in extreme cold temperatures below 33F To store coil the Connector Hose and fold the Wrap neatly on its natural folds Handle your Wraps with care Caution Do not store Wraps inside a plastic bag or other airtight container as it may promote mold growth Bag Care and Storage Wipe clean with mil
12. atment and puts pressure on the air blader If this is not the case try the following e Turn the Control Unit off and back on Apply the same Wrap more tightly e Apply a different Wrap If the problem persists call customer service at 1 888 GameReady 426 3732 e Check the hose and Wrap for kinks that might cut off fluid flow e Make sure there is water in the ice box e Make sure that the ice box filter is clean e Reapply the Wrap so that it is snug against the body part being treated If the problem persists call customer service at 1 888 GameReady 426 3732 ERROR SCREEN WHAT DOES IT MEAN Hard Error Hard Error Hard Error Hard Error TROUBLESHOOTING Dry Pump Alarm The Control Unit has detected a dry pump This error is displayed after one attempt to correct the problem has failed In order to prevent possible damage to the fluid pump the unit will stop therapy This is a Hard Error The unit needs to be turned off and restarted Pressure Sensor Alarm The Control Unit has detected a problem calibrating the pneumatic compression circuit on startup This is a Hard Error The Unit needs to be turned off and restarted Systems Error The Control Unit has determined that the fluid pump may be working too hard This could be caused by ice or debris in the fluid circuit In order to prevent possible damage to the fluid pump the unit will stop therapy This is a Hard Error The unit needs t
13. box lid pull up on the latch on the end panel of the Control Unit Fill the ice box with as much ice as possible For maximum cooling duration use cubed ice Pour water over the ice to one half inch below the rim Dry off the rubber gasket to ensure a good seal Close the lid securely and lock it into place by pulling down on the latch Note The system provides cooling to the Wrap on less ice but we recommend you fill the ice box completely Caution Do not pour hot water into the ice box Lid Supports Ice Box 4 Refilling the ice box Once the unit has been operating for more than an hour check the ice box If little or no ice remains then refill the ice box to assure maximum cooling If the unit is turned on its side place it back in its upright position before opening the ice box lid by pulling up on the latch Press the power button to turn off the unit Unplug the unit from the AC adapter and empty excess water from ice box Fill the ice box with as much ice as possible Pour water over the ice to one half inch below the rim Close the lid securely and resume therapy Note Ice can be added to the Control Unit while it is running as long as it is standing upright Connecting the Wrap to the Control Unit The connector snaps easily into place on the end panel of the Control Unit When inserted correctly the disconnect button will be on top To disconnect simply press the button and remove the connector fro
14. d Pressure Too High Alarm The Control Unit has detected that the Wrap has not properly deflated In order to prevent any possible harm to the person being treated the unit will stop therapy This is a Hard Error The unit needs to be turned off and restarted Low Flow Alarm The Control Unit has detected an interruption of fluid flow that it could not correct In order to prevent possible damage to the fluid pump the unit will stop therapy This is a Hard Error The unit needs to be turned off and restarted WHAT SHOULD I DO Once treatment has finished try the same pressure with a different Wrap if one is available When you have determined if the problem is isolated to one Wrap or not call Game Ready customer service at 1 888 GameReady 426 3732 You can continue to use your system without harming the Control Unit You can even continue using the affected Wrap but this error will persist This error can often be corrected by reapplying the Wrap so that it is snug against the body part being treated Please consult your Wrap Use Guide for more detailed instruction If the problem persists call customer service at 1 888 GameReady 426 3732 e Turn the Control Unit off and back on e Apply the same Wrap more tightly e Apply a different Wrap If the problem persists call customer service at 1 888 GameReady 426 3732 This error often comes about when the person being treated moves around dur ing tre
15. d plug the other end into an electrical outlet The system operates on AC line input 120V 60Hz or 240V 50Hz Use caution when handling your AC adapter Do not put it in water Warning Do not use any adapter other than that provided by Game Ready Ault Model MW 128 or GlobTek Model GTM21097 5012 Use of other adapters may result in electrical shock and or damage to the Control Unit and void your warranty Note If you will be using the Game Ready System with a Game Ready supplied battery pack please consult the instructions for use that accompanied that battery pack for usage details EN 14 EN 15 CARE AND STORAGE Cleaning The Game Ready System is a valuable part of your therapy equipment Please handle the Control Unit as you would a laptop computer When you are finished using the system for the day unplug the Control Unit from the electrical outlet Disconnect both the Wrap and AC adapter from the Control Unit Empty the water and ice from the ice box The interior of the ice box should be cleaned once every three months To clean the exterior of the Control Unit simply wipe with a soft cloth rinsed in a solution of warm water and any of the following agents A Mild detergent B 5 household bleach C Isopropyl alcohol off the shelf Wipe dry Do not allow liquid to pool on face plate Storage and Transportation Storage Temperature Conditions 1 50 C 33 122 F Relative Humidity 10 95 non condensing Sto
16. d soap and water air dry Caution Store the Game Ready System out of the reach of children and pets HOW TO PACK THE GAME READY SYSTEM User s Manual AC Adapter Control Unit EN 16 EN 17 TROUBLESHOOTING Soft Error When a Soft Error occurs the system will continue to run and will not fully shut down Therapy can continue even though the optimal levels are not being reached Hard Error When a Hard Error occurs the system will shut itself down and will require attention to start therapy again ERROR SCREEN Soft Error Soft Error WHAT DOES IT MEAN Under Pressure The Control Unit can t reach its target maximum compression This often indicates that there is a leak in the pneumatic compression circuit either in the Connector Hose or the Wrap itself This is a Soft Error There is no danger to the person being treated or the Control Unit and therapy will continue Low Flow Warning The Control Unit has detected a temporary interruption of fluid flow but it was able to correct the situation by reducing the compression setting This is a Soft Error There is no danger to the person being treated or the Control Unit and therapy will continue Over Pressure Alarm The Control Unit has detected excessive pressure in the air chamber In order to prevent any possible harm to the person being treated the unit will stop therapy This is a Hard Error The unit needs to be turned off and restarte
17. eturn the Game Ready Control Unit to CoolSystems you must write the RMA number on the outside of the package CoolSystems will not accept returned Game Ready Control Units without an RMA number on the package f you return the Game Ready Control Unit to CoolSystems you must assume the risk of damage or loss during shipping You must use the original packaging or the equivalent CoolSystems may require you to verify in writing that you are the original purchaser of the Game Ready Control Unit CoolSystems may elect o replace or repair the Game Ready Control Unit with either a new or reconditioned product The returned product shall become CoolSystems property upon receipt The replacement Game Ready Control Unit is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period THIS WARRANTY IS NOT TRANSFERABLE WARRANTY LIMITATIONS AND EXCLUSIONS THESE WARRANTIES REPLACE ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE COOLSYSTEMS MAKES NO EXPRESS WARRANTIES BEYOND THOSE STATED HERE COOLSYSTEMS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THIS LIMITATION MAY NOT APPLY TO YOU AL
18. g The Hose To The Wrap Note To ensure the Connector seals properly make sure that both the Wrap and Connector Hose halves are lined up straight when they are pushed together ZI de H x IMPORTANT USER GUIDELINES The Game Ready System provides intermittent compression and adjustable cold therapy by controlling fluid flow and air pressure The Control Unit software is designed to protect both the user and the Control Unit from harm by shutting off the System and sounding an alarm if there is insufficient fluid flow or an over pressure or under pressure situation To help prevent fluid flow or air pressure issues with the Control Unit please follow these guidelines Fluid Flow Like any other fluid system a reduction in fluid flow can happen because of a blockage somewhere in the fluid path like kinking your garden hose There are five ways to manage the fluid flow to prevent a blockage in the fluid path 1 Temperature Setting Always start your Game Ready System on the coldest temperature setting 3 snowflakes and run it that way for a minimum of 2 minutes before adjusting the temperature as necessary 2 Wrap Application When applying the Wraps avoid major folds or creases in the Wrap The Wraps are designed to bend around the body but if a Wrap has a big crease or fold then the fluid flow can be sufficiently reduced to cause a system shutdown The Shoulder Wrap in particular needs to be applied correctly so that there
19. he extremities or lungs Who have significant arteriosclerosis or other vascular ischemic disease in the affected region Who have a localized skin condition eg dermatitis vein ligation gangrene skin graft in the affected region Who have a condition in which increased venous or lymphatic return is not desired in the affected extremity eg carcinoma Who have erysipelas or other active infection in the affected region Who have decompensated hypertonia in the affected region e Cryotherapy using Game Ready or any cryotherapy device should not be used in patients Who have significant vascular impairment in the affected region eg from prior frostbite diabetes arteriosclerosis or ischemia Who have acute paroxysmal cold hemoglobinuria or cryoglobulinemia GENERAL WARNINGS AND PRECAUTIONS Thank you for choosing the Game Ready System To assure you have the best experience possible please be sure to read the entire User s Manual prior to use of the product Caution Federal Law restricts this device to sale by or on the order of a licensed health care practitioner WARNINGS e Improper placement or prolonged use of Game Ready could result in tissue damage such as frostbite During the course of Game Ready therapy patients should monitor the skin surrounding the treated region or the digits of the extremities of the treated limb for any burning itching increased swelling or pain If any of these signs present or any changes in s
20. is not a large crease at the tip of the shoulder 3 Switching a Wrap If you take a Wrap off one user and immediately apply it to another user be sure that the air bladder of the Wrap is completely deflated before starting treatment on the new user To deflate the Wrap simply unplug the Wrap from the Control Unit and squeeze the excess air out 4 Connector Hose To assure proper connection make sure the connector hose is securely pushed into the Wrap Do not let the Connector Hose fold over or coil unto itself when in operation this could cause a fluid flow error Avoid kinking the hose at any point along its length 5 Ice Box If you re using shaved or finely crushed ice avoid packing it too tightly as it can partially clog the filter and reduce fluid flow enough to cause a system shutdown Air Pressure When operating on low medium or high pressure the Game Ready Control Unit is designed to alert the user if it does not achieve its minimum or maximum pressure requirements It s possible for the user to make the Control Unit think it s over pressuring or under pressuring by exerting pressure on the outside of the Wrap while the system is running This will cause the Unit to shut down sound the alarm and display a PH OP UP error on the display See page 18 for details To help prevent this from happening do the following Avoid exerting sporadic pressure on the exterior of the Wrap It is fine to lie on the Wrap or
21. ive warranty service Let us know what you think of our products We d love to hear from you Game Ready CoolSystems Inc 1201 Marina Village Pkwy Ste 200 Alameda CA 94501 Phone number 1 888 GameReady 1 888 426 3732 1 510 868 2100 www gameready com EN 1 TABLE OF CONTENTS INDICATIONS FOR USE CONTRAINDICATIONS GENERAL WARNINGS AND PRECAUTIONS THE GAME READY SYSTEM Your Game Ready System Control Panel Basic Controls Priming a New Wrap Control Unit Set Up Wearing the Wraps IMPORTANT USER GUIDELINES GETTING STARTED ADJUSTING SYSTEM SETTINGS OPERATING THE SYSTEM IN THE BAG POWERING THE SYSTEM CARE AND STORAGE Cleaning Storage and Transportation Cleaning and Replacing the Filter Wrap Care and Storage TROUBLESHOOTING WARRANTY INFORMATION CONTROL UNIT PRODUCT SPECIFICATIONS HOW TO CONTACT US 20 21 21 EN 2 EN 3 C 0 N TR ATN DI C A TI O N S e Compression Therapy vasopneumatic compression using Game Ready or any compression therapy device should not be used in patients Who are in the acute stages of inflammatory phlebitis in the affected region Who have any history or risk factors for deep vein thrombosis or pulmonary embolus including prolonged bed rest in the affected region to be treated with this therapy Who have a cardiac insufficiency or congestive heart failure with associated edema in t
22. kin appearance occur such as blisters increased redness discoloration or other noticeable skin changes patients are advised to discontinue use and consult a physician The Game Ready Wrap is not sterile do not place directly against open wounds sores rashes infections or stitches May be applied over clothing or dressing Compression Therapy vasopneumatic compression with the Game Ready System should be used only under the supervision of a licensed healthcare practitioner in patients Who have a wound in the affected region the wound must be dressed prior to use of Game Ready Who have an acute unstable untreated fracture in the affected region Cryotherapy with the Game Ready System should be used only under the supervision of a licensed healthcare practitioner in patients Who have Raynaud s disease or cold hypersensitivity cold uticaria Who have hypertension or extreme low blood pressure Who have diabetes Who have compromised local circulation or neurologic impairment including paralysis or localized compromise due to multiple surgical procedures in the affected region Who are children or who have cognitive disabilities or communication barriers Who have rheumatoid arthritis in the affected region Who have known and un controlled peptic ulcer if the affected region is the abdominal region since cold therapy applied to the abdomen can cause increased gastrointestinal motility and gastric acid secretion
23. lean against a chair with a Wrap on as long as you maintain that position If you move around with a Wrap on while the Control Unit is attempting to reach pressure there is a good chance the Control Unit will shut down and sound the alarm If you want to move around while wearing the Wrap run the System without pressure EN 10 EN 11 GETTING STARTED 1 Pull up the latch to open the ice box lid Fill the Control Unit with as much ice as possible and water to 1 from the lip of the ice box Close the lid securely 2 Connect the AC adapter to the Control Unit then plug it into an electrical outlet 3 Apply the Wrap to the injured area and secure 4 Attach the Connector Hose first to the Wrap then to the Control Unit 5 Press the Power button 6 If you have a Standard Unit press the Pressure and Time Buttons to adjust the pressure and time settings If you have a Pre Programmed Unit the system will default to Pre Set Program 1 which will run for 30 minutes then will turn off sleep for 30 minutes at no compression Each Program will continue the pre set 30 30 on off cycle indefinitely Press the Timer button to scroll through the Programs Pre Set Program 1 Pre Set Program 2 Pre set Program 3 30 minutes on with 30 minutes on with 30 minutes on with no pressure low pressure medium pressure 30 minutes in sleep mode 30 minutes in sleep mode 30 minutes in sleep mode A 30 30 No Pressure AWA 30 30
24. m its port When disconnecting the Connector Hose from the Control Unit it is normal for a few drops of water to drip from the Connector Hose nozzle Be sure not to hold the button down while connecting the Wrap to the Control Unit Disconnect Button EN 8 EN 9 WEARING THE WRAPS WARNINGS If used incorrectly cold therapy can cause frostbite or other tissue damage During the course of Game Ready therapy patients should monitor the skin surrounding the treated region or the digits of the extremities of the treated limb for any burning itching increased swelling or pain If any of these signs present or any changes in skin appearance occur such as blisters increased redness discoloration or other noticeable skin changes patients are advised to discontinue use and consult a physician The Game Ready Wrap is not sterile do not place directly against open wounds sores rashes infections or stitches May be applied over clothing or dressing For more information on a specific Wrap see the Use Guide packaged with the sleeve After fastening the Wrap on yourself or another person connect the Wrap to the Control Unit Press the power button Adjust the timer pressure and temperature settings After treatment remove the Wrap from yourself patient and disconnect from the Control Unit Caution If applying the same Wrap to another person make sure the Wrap is deflated before the next application Connectin
25. o be turned off and restarted Self Test Error The Control Unit has detected an electronic problem at startup This is a Hard Error The unit needs to be turned off and restarted WHAT SHOULD I DO e Make sure there is water in the ice box e Verify that the ice box filter is not clogged e Turn the Control Unit off and on again Select No Pressure and run the system for 1 minute using the largest Wrap available lying it on the floor or table next to the Control Unit not on the body If the problem persists call customer service at 1 888 GameReady 426 3732 e Disconnect the Wrap from the Control Unit Turn the Control Unit off and on again without a Wrap connected This should clear the error If the problem persists call customer service at 1 888 GameReady 426 3732 e Turn the Control Unit off and back on again e Check the filter e f that does not solve the problem turn the Control Unit off for 20 minutes before turning it on again to try again If the problem persists call customer service at 1 888 GameReady 426 3732 e Disconnect the Wrap from the Control Unit e Turn the Control Unit off and on again without a Wrap connected If the problem persists call customer service at 1 888 GameReady 426 3732 EN 18 EN 19 TROUBLESHOOTING System will not turn on Check that the AC adapter is securely plugged into a working electrical outlet Control Unit
26. out this manual Read and carefully follow these instructions prior to operating the System EN 4 EN 5 UL SAFETY CLASSIFICATION INFORMATION 1 Protection against electric shock 5 1 The Game Ready power supply Ault Model MW128 provides Class grounded equipment protection The Game Ready power supply GlobTek Model GTM21097 5012 provides Class II ungrounded equipment protection 2 Protection against harmful ingress of water 5 3 This product provides ordinary protection against ingress of water 3 Degree of safety in the presence of flammable anesthetics or oxygen 5 5 Not suitable for use in an oxygen enriched environment or in the presence of flammable anesthetics 4 Mode of operation 5 6 The equipment operates under continuous operation and continuous operation with intermittent loading if operating the system continuously without a full load of ice Users should allow the system to rest for at least 15 minutes between each 90 minute reatment 5 Electromagnetic Interference This equipment has been tested and found to comply with the limits for medical devices in IEC 60601 1 2 1994 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity Howeve
27. r here is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer ence by one or more of the following measures reorient or relocate the receiving device increase the separation between the equipment connect the equipment into an outlet on a circuit different from that to which the other device s are connected consult the manufacturer or field service technician for help Medical Equipment With respect to electrical shock fire and mechanical hazards only in accordance with UL 60601 1 CAN CSA C22 2 No 601 1 lt 61ZJ gt Powered by Direct Current Type B Applied Parts Attention Consult accompanying documents before use a RE a YOUR GAME READY SYSTEM Control Unit Heat Exchanger Sleeve Carry Bag optional Connector Hose NAN pter lt lt User s Manual CONTROL UNIT ORIENTATIONS Figure A Upright Figure B Side The Control Unit can sit upright Fig A or on one side Fig B to fit on a shelf Caution Do not put the unit on the side where the control panel is upside down This will cause the unit to leak water Note The Wrap is comprised of an inner heat exchanger and an outer sleeve The combi nation of sleeve and heat exchanger is referred to throughout this manual as a Wrap EN
28. re the Game Ready System in the carrying case or on a shelf preferably with the lid open to allow the interior to dry Caution Do not keep in extreme hot or cold temperatures above 122 F or below 33 F Avoid leaving in the trunk of a hot or freezing car Cleaning and Replacing the Filter Your Game Ready unit is equipped with a special filter designed to keep dirt and debris out of the fluid system To assure consistent flow of water through the system the filter should be checked and cleaned every three months of regular use Caution If the filter becomes clogged the Control Unit alarm will beep the low flow icon will flash and the unit will go into pause mode Check to be sure the filter is not clogged In addition to cleaning the filter every three months it should be replaced after one year of regular usage Call us toll free at 1 888 GameReady for a free replacement filter To clean or replace the filter follow these steps 1 Turn off power and unplug the system from its electrical outlet 2 With the Control Unit in the upright position open the ice box door Figure A 3 Empty any water and ice in the ice box 4 Locate the filter inside the ice box with your hand as shown in Fig A 5 Press the silver metal button on top of the filter as shown in Fig B You should hear a click as the filter is released 6 Pull the filter straight out from its housing Note The release button is part of the housing
29. with the lip of the ice box If the gasket is damaged call Game Ready customer service at 1 888 GameReady for further assistance WARRANTY CONTROL UNIT CoolSystems warrants that the Game Ready Control Unit if properly used will be free from defects in material and workmanship for a period of one 1 year after the date the Game Ready Control Unit was purchased f the Game Ready Control Unit which is the subject of this Limited Warranty fails during the warranty period or reasons covered by this Limited Warranty CoolSystems at its options will e REPAIR the Game Ready Control Unit OR e REPLACE the Game Ready Control Unit with another Game Ready Control Unit THIS LIMITED WARRANTY AND ANY IMPLIED WARRANTIES THAT MAY EXIST UNDER STATE LAW APPLY ONLY TO THE ORIGINAL PURCHASER OF THE GAME READY CONTROL UNIT AND ARE NON TRANSFERABLE Extent of Limited Warranty This limited warranty does not cover damages due to external causes including without limitation accident usage not in accordance with product instructions misuse neglect alteration or repair How to Obtain Warranty Service To obtain warranty service call toll free 1 888 GameReady You must have returned the Warranty Registration card to CoolSystems within thirty 30 days from the date of purchase to qualify for warranty service If you qualify for warranty service from CoolSystems you will be issued a Returned Material Authorization RMA number When you r
Download Pdf Manuals
Related Search
Related Contents
A13-OLinuXino and A13-OLinuXino-WIFI CTA Digital VIT-CS mobile device charger Acer Aspire E1-570-33214G1TDnkk INSTALLATION MANUAL OPERATION MANUAL INSPECTION LOG Celestron SPX900 Camcorder User Manual Instruction Booklet Philips Norelco SmartClick RQ585 Service Service Service IC-7410 SERVICE MANUAL manual - Woodall Research Group Copyright © All rights reserved.