1. 4 Only month mm 5 Only year yy 6 Serial number 6 For initialization of serial no write zero to eight digits Serial no here Serial no more than eight digits not allowed 7 Repeated serial no 8 Only day dd A Not Applicable B Operator code 1 C Operator code 2 D Shift From 07 15 am to 03 45 pm Shift A From 03 45pm to 12 15 am Shift B From 12 15 am to 07 15 am Shift C E Incremented serial no F Not Applicable G Not Applicable H Not Applicable I Not Applicable J Not Applicable K Lot no Appendix 2 Date and time format ddmmyyhhmmss no blank space allowed E g 231007164530 Date 23 10 2007 Time 04pm 45Min 30Seconds Appendix 3 Modifications in Software version LDSP_LCD_10_1 4 Applicable to LDSP_LCD_99 Two separate triggers added in this version as follows DOUBLE TRIGGER MODE PHY SRL trigger This is dual trigger mode i e unless and until both triggers are received label will not be printed In this mode of trigger sequence first LDSP_LCD_10 will accept serial trigger first and after that physical trigger will be accepted SRL PHY trigger This is dual trigger mode i e unless and until both triggers are received label will not be printed In this mode of trigger sequence first LDSP_LCD_10 will accept serial trigger first and after that physical trigger will be accepted In both of above modes during seria
2. Bits Stop Bits and Handshaking select according to LDSP_LCD_99 CONFIGURATION Terminal v1 9b 20040204 by Bray COM Port gt gt Baud rate Data bits gt Parity Stop Bits Handshaking oma COMI C 600 C 14400 C 57600 C5 none e none Disconnect Ai C 1200 19200 115200 e g C odd C RTS CTS i 2400 C 28800 128000 C even C 1 5 C XON XOFF About m 3 C 4800 C 38400 C 256000 C mak a C RTS CTS XON XOFF Quit H C 900 C 56000 custom 8 space v2 C RTS on TX J Auto Dis Connect Time pustomER Sce ecne EENCTS Esa GEICO RI I Stay on Top J CR LF 9600 Oy Receive C HEX CLEAR _ResetCounter 13 Counter 0 Sting StartLog Dec Hex f Bin Transmit CLEAR Send File P CR CR LF Dm RTS gt Send Transmit Macros z fo 2f z m foo 2f z ma fioo f r Connected ig Start Terminal Connected R O m 10 05AM Note For Barcode reception select even parity instead of no parity and let rest of the setting s remain unchanged For ex Above configuration is for 2400 baud 8 data bits no parity 2 stop bits and no handshaking Appendix 1 Selection of Printing Format User can modify default label file as follows add at the start Part number if want you can initialize part number otherwise remove tildes i e Label Data 1 2 3 4 5 6 6 7 8 9 A B C D add at the end N99 1 Date dd mm yy 2 Time hh mm ss 3 Week
3. User s Manual Lpsp_Lcp_99_2 Of Label Data Storage for Printing LDSP_LCD_99 By Futura Apsol Pvt Ltd 1212 B 2 Apte Road Shivajinagar Pune 411 004 Telefax 020 25531832 www futuras com sales futuras com Software Version LDSP_LCD_99_2 0 12 12 13 Label Data Storage For Printing Unit LDSP_LCD_99 Packing List Label Data Storage For Printing L DSP_LCD_99 1 No This User s Manual 1 No Interfacing Cable for PC rs232 9 pin m 9pin f Trigger Cable 9 pin f other end open Cable for serial printing 1 to 1 9 pin m 9pin m Cable for serial printing cross 9 pin m 9pin m A CD containing software for serial Communication with LDSP_LCD_10 1 no LDSP_LCD_99 serial NUMDEL c0cccccecceneee ee INDEX 1 Front view of LDSP 2 Introduction 2 1 Function 2 2 Description of system 2 3 Technical Specifications 2 4 General Features 3 Installation A Create label file download in LDSP and print B Down load date and time 4 Operations 4 1 State Diagram 4 2 Menus and submenus 4 3 Keys and meaning 4 4 Meanings of various displays 4 5 Interfacing with Pc 4 6 Interfacing with Printer 4 7 Interfacing with Barcode scanner 4 8 Interfacing with Yc checker 4 9 Downloading Label Data 4 10 Downloading Date and Time 5 Description of menus 6 Details of terminal softwa
4. al protocol 3 Maximum 99 different label data of 2 KB each can be stored 4 User interface is with four keys and 16 2 LCD display 5 Printer interface is through 25 pin D type connector for parallel port printer and 9 pin D type F sub for serial printer 6 Can be interfaced to any printer having parallel port or serial port 7 Variable data such as date time week serial no operator codes shift times incremented serial No Part no and lot no can be generated through LDSP for printing 8 Variable captured from serial trigger can be printed on label 9 Two serial ports are available one for input one for out put 3 Installation Installation procedure of LDSP A Create label file download in LDSP and print 1 Design label on PC using label design software provided with label printer Print this label by connecting PC to printer 2 Open this prn file to note pad and add at the start and at the end of label file Reference Demo label file example given with in the CD 3 Connect printer to LDSP through printer cable Power on printer and let him take ready to print status 4 Connect LDSP to PC s serial port through standard modem cable 9 pin m 9pin f and download label file in to LDSP Refer operation section for downloading 5 After successful downloading of label data demo label print will come 6 For different variables such as date time serial no etc required by user modify label file as Refe
5. d time will be assigned to LDSP For date and time file refer to example file given with the CD 4 11 Receiving Operator Codes use serial port 1 for any type of communication with PC Enter in to Operator Code Reception Menu and display will be Receiving Operatorcode1 Scan first barcode using barcode scanner Scan second barcode using barcode scanner Both codes can be now retained up to power on You can print both the codes using variables codes refer appendix 1 5 Descriptioin of menus 5 1 Receive Trigger In this menu LDSP is asking to enter in to receive trigger mode 5 2 Waiting for Trigger In this mode LDSP is waiting to accept trigger It will not do any other key operation unless escaped from this state through ESC key 5 3 Select label data In this mode user can select desired label location 5 4 PC to Label data In this mode LDSP can accept label data from PC with the help of terminal software 5 5 Pc to Data and Time In this mode LDSP can accept date and time from PC with the help of terminal software 5 6 Operator codes In this mode user can accept operator codes via barcode scanner 5 7 Receive Compare data Comparison data reception and storing 5 8 serial test This menu is reserved for FUTURA 6 Details of Terminal software screen are as follows use for sending data through PC e Click connect e Select proper com port e Baud Rate Data Bits Parity Start
6. e For ex UAA i e OxAA At every U following value will be sent to the printer port I e in above example hex AA will be sent to port Appendix 6 Modifications in Software version LDSP_LCD_10_2 1 Applicable to LDSP_LCD_99 Special variable i e T has been added T 5 Year in the special format will be printed i e 2010 F 2011 G 2020 P T 4 Month in special format will be printed i e JANUARY A FEBRUARY B DEC L T 8 Day in special format will be printed i e Date 1 A 2 B 26 Z 27 1 31 5 D Shift will be printed 07 15am to 03 45pm Shift A 03 45pm to 12 15am shift B 12 15am to 07 15am shift C For Ex For the date 13 10 12 12 00 00 Then FLMA will be printed Appendix 7 Modifications in Software version LDSP_LCD_10_2 2 Applicable to LDSP_LCD_99 e Serial number clearing facility has been given in set up menu After selection of clear serial number option in set up menu serial number of selected label location is cleared and next print will start from one e CLEAR SERIAL NUMBER ON SHIFT CHANGE This setting can be enabled or disabled according to requirements If this setting is enabled then after changing of shift all 25 serial numbers will be cleared automatically Special care should be taken for shift B At every 00 am in the mid night date changes Shift B timings are 15 46 to 00 15 So during shift B running if LDSP is switched of and powered on directly nex
7. ill last until next edition If SHIFT_ DATE_CLR_SERIAL_NUM is disabled in power on escape key menu then on every Shift change by user all 99 serial numbers will be cleared Shift code can be printed on label by Z OPERATOR CODE operator code is 6 digit wide compulsory and of numeric type User can edit operator code as pee requirement Operator code will remain store until next updation Operator code can be printed on label by a Old menus such as operator code barcode mode receive compare data serial test clear serial no Are removed as they were of no use SHIFT_DATE_CLR_SERIAL_NUM This setting is available in power on esc key menu ON All 99 serial numbers will automatically cleared on date change at 00 hrs midnight OFF All 99 serial numbers will be cleared on shift change manually by user Comparison setting is removed from power on esc key menu Setting limits compare from and to will compare serial barcode within the limits with stored part number
8. in serial reception mode 9 Demo Label print Indicates Idsp is printing demo label print after saving label data 10 Printing Indicates LDSP_LCD is printing label data 11 Selected Indicates desired label location is selected 12 Part no empty Indicates that part no is absent at current label location 13 Lot no empty Indicates that lot no is absent at current label location 14 Label Data empty Indicates that label data is absent at current label location 15 Check Key Indicates wrong key press 16 Error Indicates that error has been occurred during reception 17 Chk Lbl File Indicates that check label file transmitted may be exceed capacity or wrong format 18 Chk Srl Conn Indicates that problem may be in serial connection checks it 19 Not Available Indicates that feature is not available in this version 20 Operator Code 1 Indicates that ready to receive first operator code 21 Operator Code 2 Indicates that ready to receive second operator code 22 Receive Compare data Asks user to send data on serial for comparison 4 5 Interfacing with PC Connect standard modem cable 9 pin m 9pin f to PC s serial port 1 at one end and LDSP s serial port at another end 4 6 Interfacing with Printer Connect printer cable to printer at one end centronics and LDSP 25 pin D type at printer port provided
9. ion Selected Receiving Receiving Operator code 1 Waiting for data from barcode code scannar 2 times Trial TE 4 Digit Lot no Select Trial as Select Trial as Enter 4 digit lot no amp select lot no lot no lt Key board flow for operation 8 Digit Lot no Enter 8 digit lot no amp select it 4 2 Menus and Submenus Menu name and keys accepted Receive Trigger Enter Up Down Waiting for Trigger Esc Setup Up Down Esc Enter Select Label Data Up Down Esc Enter Pc to label data Up Down Esc Enter Pc to date and time Up Down Esc Enter Operator codes Up Down Esc Enter Receive compare data Up Down Esc Enter Serial test Up Down Esc Enter Clear serial number Up Down Esc Enter 4 3 Keys and meanings Enter Key For accepting command Esc Key For Previous Menu Up Key Increment key Down Key Decrement key 4 4 Meanings of various frequent displays 1 Receive trigger Asking LDSP to be ready for accepting trigger 2 Waiting for trigger Indicates that LDSP is ready to accept trigger 3 Set up For entry in set up mode 4 Select Label Data To select label location of your own choice 5 Pc to Label Data To enter into label data reception mode 6 Pc to Date and Time To enter into date and time reception mode 7 Receive Operator Codes To enter in to operator code reception mode 8 Receiving Indicates LDSP_LCD is
10. l triggr reception data is to be compared with all part number stored in LDSP If match occurs same part number label will be printed In any of above two modes LDSP will configure parallel port as a default printer port All the trigger settings are available in power on authority menu Part number in label data will be stored as follows PART NUMBER gt MAXIMUM 14 DIGITS ALLOWED NORMAL LABEL DATA Shift timings are modified in this versions as follows Shift can be printed on the label by D 7 15 am to 3 45 pm gt shift A 3 45 pm to 0 15 am gt shift B 0 15 am to 7 45 am gt shift C Appendix 4 Modifications in Software version LDSP_LCD_10_ 1 6 Applicable to LDSP_LCD_99 Single serial trigger is modified in this version as follows PART NO MATCH SETTINGS Part number match setting mode is added for single serial trigger If part no match setting is on and trigger type selected is single trigger then serial trigger is compared with existing part number and label will be printed If part number match setting is enabled then compare data setting will automatically disabled And vice versa Part number match setting will be available through authority menu Appendix 5 Modifications in Software version LDSP_LCD_10_2 0 Applicable to LDSP_LCD_99 New variable i e U is added for label printing U followed by two characters will represents single byte hex valu
11. or connect serial port 2 9 pin F via serial cable to printer 4 7 Interfacing with Barcode scanner Connect cross cable 9 pin m 9 pin m to Idsp at one end and scanner at other end 4 8 Interfacing for trigger For physical Trigger Connect trigger cable 9 pin f to ldsp at one end and connect two wires to potential free trigger for example relay For serial trigger Connect serial cable to trigger source and 9 pin D type sub connector i e serial 1 4 9 Downloading Label data use serial port 1 for any type of communication with PC Power on LDSP enter in to set up menu and select label location at which you want to save the label file Otherwise label file will be saved on previously selected label location Again enter in to PC to label data mode from setup menu and wait till it displays receiving Now Send label file through PC with the help of terminal software with appropriate setting refer section 6 Cursor will start blinking as indication of reception starts After saving the data demo label print will come out For label file refer to example file given with the CD 4 10 Downloading Data and Time use serial port 1 for any type of communication with PC Enter in to PC to data and time menu from set up menu and wait till display receiving Send date and time file through terminal software with appropriate settings refer section6 After saving new date an
12. re Label Data Storage For Printing Unit 1 Front View of LDSP_ LCD 16 2 LCD Display ESC ENTER 4 keys sealed keyboard 2 Introduction 2 1 Function This LDSP_LCD_99 is specially developed for storage and sending of label data to printer LDSP will send data to printer after every trigger Along with label data user can select variables such as date time month year week serial number operator code etc for printing 2 2 Description of System POTENTIAL FREE TRIGGER OR SERIAL TRIGGER LDSP_LCD_99 PARALLEL OR SERIAL PORT PRINTER SERIAL OR PARALLEL PRINTER CABLE ONLINE SET UP OF SYSTEM 2 3 Technical Specifications 1 Power Supply 0 230 AC 50Hz 10 2 Communication Protocols RS 232 Start bit 1 Stop bit 1 Handshaking None Baud Rate selectable 1200 2400 4800 9600 19200 Parity selectable no parity or even parity Parallel 8 data bits 1 strobe 1 busy 25 pin D type to 36 pin centronics interface 3 User Interface a 4 key keyboard Up key Increment key Down Key Decrement key Enter Key Accept command Esc Key Previous Menu b 16 character 2 LCD display for visual interface 4 Mechanical Dimension 200 120 90 mm ABS body 2 4 General Features 1 LDSP_LCD_99 is specially developed for data storage and send data to printer after triggering 2 PC interface will be through RS232 seri
13. rence Appendix 1 7 Now select waiting for trigger status of LDSP to make it ready to accept trigger from your triggering unit Made appropriate trigger connections via trigger cable provided with LDSP B Download date and time 1 Connect LDSP to PC serial port through standard modem cable 9 pin m 9pin f and download label file in to LDSP 2 Refer operation section for downloading data and time in to LDSP Also refer date and time example given with CD C Enter Lot no or Select default lot no Not available in this version 4 Operation 4 1 State Diagram This is the common menu only for key reference updates in this menu are available in concurrent appendix Futura Apsol Pvt Ltd Enter Key Esc Key Up Key L Version xx dsp a Down Key Label Data xx Displays previous selected location Receive trigger enter key up down key Waiting for trigger Set Up Set up Ldsp will wait for Menus trigger Accept Command Previous Menu Increment Key Decrement Key represents displays of LDSP_LCD L Containts in boxes represents functions Select Label Data Pc to label Data Pc to Date and time Operator codes Lot No change serial no select cheker type Selection Label Data of label Reception Date and Time Operator code r location Mode Reception Reception Mode Lot no Menu Not Available in Not Available in Mode this version this vers
14. t night in_ shift B between time 00 00 to 00 15 then older serial number will be retained Supervisor has to manually reset it for this special case Appendix 8 New features for LDSP_LCD_99 1 2 e Label location capacity is increased from 25 to 99 with 2k label size each e Second serial port is added for data out Hence serial port 1 is used for pc communications i e receiving label data date and time etc as well as receiving serial trigger if applicable And serial port 2 is dedicatedly used for data out output i e for label printing and other customized features Modifications in Software version LDSP_LCD_99 2 0 gt 1 Four new menus added in set up menu LOT NUMBER lot number type can be selected such as TRIAL PP 4 digit and 8 digit mode In 4 and 8 digit mode actual lot number can be selected through key board Separate lot number is available for each location number Lot number can be printed on label By K After every lot number change by user through key board serial number of selected location will be cleared ENTER SERIAL NUMBER Serial number can be edited through key board in enter serial no Each location has its separate serial number and no of digits are initialized in label file only But it can be edited in between by this menu SELECT SHIFT Shift code A B C G are available through this menu User can manually change shift code as per requirement and changed shift code w