1. Operating Manual Fuora Q R b Gas Outdoor Fireplace For Use in Open Spaces SPARTHERM PREFACE Dear customer Thank you for choosing to buy a SPARTHERM product We hope you enjoy the comfortable cosy fire of your gas fireplace Our products have been developed and produced according to the highest quality and safety requirements For this reason you can enjoy many years of trouble free use guaranteed In this booklet you can find instructions for installing and using your new unit Read the instructions and the user s manual well so that you can familiarise yourself with the unit If you would like more support you can contact your dealer or installer Your SPARTHERM Team o VA l in A G M Rokossa OVERVIEW OF THE OPERATING MANUAL GAS OUTDOOR FIREPLACE 1 Warning 2 Installation instructions 2 1 Propane installation instructions 3 Technical data 4 Safety Instructions 5 Commissioning the unit 5 1 Switching the unit on 5 2 Burner flame 5 3 Adjusting the flame height 5 4 Switching the unit off 5 5 Warning If you smell gas 5 6 Removing the glass casing oO o o o o o N 6 Gas cylinder adapter 6 1 Adapter for the connection 7 General warranty conditions 7 1 Area of application 7 2 General information 7 3 Warranty period 7 4 Warranty requirements 7 5 Exclusions from the warranty 7 6 Elimination of defects repair 7 1 Extension to the warranty period 7 8 Spare parts 7
2. This gas fireplace is only suitable for propane The unit is intended exclusively for outdoor use It is not suited for installation in buildings garages or closed structures or in on vehicles or boats WARNING This gas fireplace should never be used underneath a combustible structure or combustible materials and should never be placed in the immediate vicinity of other combustible materials WARNING The installation and maintenance of the unit should be conducted by a recognised gas fitter Local regulations should be followed in the process Improper installation adjustment alteration care or maintenance can result in damage or injury WARNING Follow all the instructions provided in the manual regarding gas leak detection before operating the unit Never try to loosen the gas fitting when the unit is in use WARNING Do not use or store petrol or other flammable vapours or liquids near this or other units WHAT YOU SHOULD DO IF YOU SMELL GAS Close the gas supply extinguish any fires and then contact your gas fitter and follow his instructions If you cannot reach your gas fitter you should contact the fire brigade WARNING This unit may not be used on a flammable surface such as a wood table WARNING Transporting the unit must only be conducted with the four secured cotter pins in place The cotter pins are included with the unit and are to be inserted in the gas cylinder compartment in the perforated steel plates of t
3. 49 0 54 22 9441 0 Fax 49 0 54 22 9441 14 Model Fuora Q R Versions Propane Butane Country of destination Germany FRG Standard EN 14543 A1 PIN Number CE 00630603494 Propane connection Pressure regulator 50mbar Heat output 3 7 kW MODEL Fuora Q R Suitable types of propane EE KE KE KE KE eet oo ow om om Country of destination Germany Manufactured by Spartherm Feuerungstechnik GmbH CE 0063 PIN 0063603494 Serial number 30100001 e Designed exclusively for use outdoors e Read the user s manual well before you operate the unit e The individual parts can become very hot keep the unit out of reach of children e The unit is intended for heating purposes e The unit has an open fire Always ensure the safety of children and elderly infirm persons 4 SAFETY INSTRUCTIONS Please read these safety instructions carefully before operating the gas fireplace If the information from the instructions is not strictly followed fire or explosion could result which could lead to property damage serious bodily injury or even death WARNING Improper installation adjustments changes care or maintenance can result in injury or damage Consult the user s manual which is included in this delivery If you have questions or would like additional information please contact an authorised gas fitter When igniting the burner make sure that the valve of the gas cylinder is opened fully WARNING
4. on going quality control Specialist knowledge is required when assembling and installing the product The product must therefore only be installed and commissioned into service by specialist technical staff in compliance with current Statutory provisions 7 3 WARRANTY PERIOD The standard warranty terms only apply within Germany and the European Union The warranty period and scope of the warranty are ensured within the framework of these conditions outside the statutory warranty which remains unaffected Spartherm Feuerungstechnik GmbH offers a 24 month warranty in respect of the housing operating components such as handles setting levers 10 shock absorbers electrical and electronic components such as fans rotational speed controllers original spare parts the pressure regulator all items purchased as extras and all safety appliances Spartherm Feuerungstechnik GmbH offers a 6 month warranty in respect of consumables mounted in the combustion firebox area such as the fire clay vermiculite fire grates seals and glass ceramics 7 4 WARRANTY REQUIREMENTS The warranty period shall begin on the date when the product is delivered to the dealer intermediary This is to be substantiated by documentation such as invoices or delivery notes by the dealer intermediary The warranty certificate for the product must be presented by the claimant upon making a warranty claim Spartherm Feuerungstechnik GmbH is not obliged to sa
5. steel lugs Fig 11 Then the glass can be carefully lifted up Fig 12 6 GAS CYLINDER ADAPTER Pressure reducer with a pressure relief valve For commercial use in Germany Order number 1033198 Adapter fitting 1 Italy Switzerland Small cylinder external thread x external thread M 10 x 1 Order number 1034297 Adapter fitting 2 Italy Small cylinder external thread x internal thread W 20 x 1 14 LH Order number 1034298 Adapter fitting 3 Belgium Denmark Finland Luxembourg Norway Austria Portugal Scotland Switzerland Italy Sweden Small cylinder external thread x external thread M 14 x 1 5 Order number 1034300 Adapter fitting 4 Denmark England France the Netherlands Italy Austria Switzerland Spain Small cylinder external thread x internal thread W 21 8 x 1 14 LH Order number 1034302 7 GENERAL WARRANTY CONDITIONS 7 1 AREA OF APPLICATION These standard warranty terms apply for the contractual relationship between the manufacturer Spartherm Feuerungstechnik GmbH and the dealer distributor These warranty conditions are not identical to the contractual and warranty conditions governing relations between the dealer or distributor and its customers 7 2 GENERAL INFORMATION This product has been manufactured in compliance with current standards of quality control The materials used have been carefully selected and like our entire production process are subject to
6. 9 Liability 7 10 Closing remarks 10 10 10 10 10 10 11 11 11 11 11 1 WARNING e Read the instructions carefully before using the gas outdoor fireplace Fuora and keep the instructions for future reference e This product and if applicable the gas cylinder should be installed in accordance with the instructions in this manual as well as with all applicable national and or local regulations e The distance from flammable materials to the fireplace should be at least 1 5 metres e Never leave the fire unattended e Do not move the gas outdoor fireplace Fuora when it is hot or in operation e Keep children out of reach of the product while it is in use and until it has completely cooled down e Caution Touching the hot parts can cause blisters A safety device has to be provided to keep children as well as frail or disabled people from coming too near to the unit e Always shut off the gas valve before moving the product e Shut off the gas supply after use e Never perform repairs on your own and do not make any changes to the unit e Do not block the air flow in the direction of the burner and or the injector e Do not interfere with the air flow in the direction of the gas cylinder housing e In the case of strong wind place the unit in a sheltered location to prevent it from overturning e In the event of a gas leak close the gas cylinder or shut the gas valve connected to the main gas supply e f you inst
7. all a separate device in which to place the gas cylinder be sure that the cylinder is well ventilated Propane is heavier than air and an accumulation of this gas can have dangerous consequences If you have any questions about the instructions in this manual please contact your sales outlet e tis dangerous and illegal to use this unit in an enclosed space The unit has been developed for outdoor use 2 INSTALLATION INSTRUCTIONS Packaging contents 1 Fully assembled burner 1 Bag of 8 16 mm lava stones 1 x Operating manual and installation manual 1 Cover if a glass top is not provided 1 Aluminium base with castors and levelling feet for safety 1 Rubber piece for mounting the gas cylinder 1 Pressure regulator 0 4 m gas hose 1 Tip protection valve Unpacking Once you have unpacked everything you should dispose of the packaging appropriately Usage If your gas fire is set up in commercial areas use a pressure reducer with a pressure relief valve This is available for purchase as an optional component see page 9 Caution If you need assistance when installing the fireplace please contact your dealer 2 1 PROPANE INSTALLATION INSTRUCTIONS 1 Connect the pressure regulator to the gas cylinder left handed thread the maximum allowable filling amount is 10 5 kg To do so use suitable adjustable pliers It is not enough to tighten it by hand This could allow a leak to occur Replace the gas cylinder only in we
8. he upper part of the glass Fig 2a b Note The four cotter pins must always be used 9 COMMISSIONING THE UNIT 1 Remove the weather protection hood if provided 2 Check that the gas is connected correctly to the gas cylinder and open the cylinder Secure the gas cylinder with the rubber mounting piece 3 The gas outdoor fireplace Fuora is operated with the gas regulator located behind the fireplace door 4 In order for the gas to be able to flow to the burner the tip protection Fig 3 has to be aligned horizontally pa 1i aega INCORRECT CORRECT _ INCORRECT Fig 3 9 1 SWITCHING THE UNIT ON 1 Turn the ignition knob on the gas control panel Fig 4 as far to the right as possible Push in the ignition knob Then turn it to the left keeping it pushed in until you hear a click Fig 5 This click is the ignition of the pilot light If necessary repeat this process 3 5 times until the pilot light is burning 2 Once the pilot light is lit continue holding in the ignition knob for another 10 seconds Then release the ignition knob 3 If the pilot light goes out repeat steps 1 and 2 until the pilot light starts burning Caution If a new gas cylinder is installed or the fireplace has not been used for a while you first have to release the air from the gas hose This may take a while before the pilot light ignites 5 2 BURNER FLAME After the pilot light starts burning the ignitio
9. ll necessary repair work resulting from material or manufacturing defects shall be conducted free of charge and shall not invalidate the remaining provisions of the warranty Within the scope of this warranty promise Spartherm Feuerungstechnik GmbH reserves the right to either remedy the fault or replace the device free of charge The elimination of defects shall take precedence The terms of this warranty shall not extend to any damage or compensation not covered by statutory provisions 7 7 EXTENSION TO THE WARRANTY PERIOD The warranty period shall automatically be extended when claims made in respect of these guarantee provisions result in the repair or replacement of defective equipment 7 8 SPARE PARTS Only the manufacturer s own components or replacement parts recommended and approved by him shall be used for appliance servicing and repair 7 9 LIABILITY Damages and claims for compensation which are not the result of delivery of a defective device from Spartherm Feuerungstechnik GmbH are excluded and are not part of this warranty promise The above shall not include claims made in respect of statutory legal requirements 710 CLOSING REMARKS In addition to these warranty conditions and our commitment to them our dealers and contractual partners are pledged to assist you in both word and deed We expressly recommend that our fireplaces and stoves be inspected regularly by a qualified technician 11 The global brand f
10. ll ventilated areas and not near candles cigarettes or other flammable sources 2 Caution Before connecting the pressure regulator always ensure that the rubber gasket is present and undamaged If not the device must not be used until the gasket is replaced 3 Make sure that the gas cylinder is always standing upright The gas hose must not come into contact with sharp objects or edges which could damage the inner tube Be sure that the gas hose does not come into contact with hot parts of the burner 4 Check all of the connections for leaks To do so moisten all of the gas connections with soapy water or use a gas leak detection spray If bubbles arise in the suds or the gas leak detection spray there is a leak 5 Distribute the supplied ca 0 9 kg 8 16 mm lava stones in the form of a small hill Fig 1b on the burner bed Be sure that no small pieces of stone enter the burner Also be sure that no stones are lying on the thermal element The fireplace is now ready for use 6 Now the two adjustable feet on the bottom of the gas fireplace have to be adjusted in order to ensure a secure footing Warning Check the gas hose at least once a month as well as each time you change the gas cylinder If the hose shows signs of cracks or other damage it should be replaced by a tube of the same length and quality 3 TECHNICAL DATA Manufacturer Spartherm Feuerungstechnik GmbH Contact details Postbox 1751 D 49324 Melle Phone
11. n knob Fig 6 has to be turned to the left Now the main burner Fig 1 is supplied with gas 9 3 ADJUSTING THE FLAME HEIGHT 1 The desired height of the gas flame can be adjusted by turning the flame height controller Fig 7 to the right or left 2 For a lower gas flame turn the knob clockwise to the right Fig 8 3 For a higher gas flame turn the knob clockwise to the left Fig 7 5 4 SWITCHING THE UNIT OFF 1 By turning the ignition knob to the right again Fig 4 you will shut off the gas supply and the fire will go out Then the gas cylinder has to be closed 5 5 WARNING IF YOU SMELL GAS Never ignite the unit if you smell gas If the unit is on when you smell gas you have to interrupt the gas supply close the gas cylinder or the gas valve Then check all of the connections for leaks To do so moisten all of the gas connections with soapy water or use a gas leak detection spray If bubbles arise in the suds or the gas leak detection spray there is a leak You can only use the unit again after all the leaks have been sealed Please consult your dealer if necessary 5 6 REMOVING THE GLASS CASING The glass casing is fitted on the body and is secured on the sides with four steel lugs Fig 9 The steel lugs are inserted through the coated body and are secured in the gas cylinder compartment with four cotter pins Fig 10 To take off the glass casing the four cotter pins must be removed from the
12. or your lounge Product inspected by Day Month Year Your specialist dealer U SPARTHERM 2 Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Phone 49 0 5422 94 41 0 Fax 49 0 5422 9441 14 www spartherm com A1 GB SP 0 000 12 2014
13. tisfy any claim if such documentation is not presented 7 5 EXCLUSIONS FROM THE WARRANTY These warranty provisions do not cover e component wear e fire clay vermiculite i e natural products which expand and contract on exposure to cyclical heating and cooling This can cause cracks to appear The combustion chamber linings will remain fully functional provided they are still in position and are not broken e the upper surfaces discolouration of the coating or galvanic surfaces due to excessive thermal loading or over heating e the push up mechanism failure to comply with installation guidelines resulting in over heating of the guide rollers and bearings e seals reductions in sealing strength due to seal hardening as a result of thermal loading e glass ceramics soiling due to soot or other burnt on combustion materials and visual deterioration due to thermal loading e careless transportation or incorrect storage e inappropriate or careless handling of fragile components such as glass or ceramics e incorrect operation and or use e lack of maintenance e incorrect installation or equipment connection e failure to comply with installation guidelines or operating instructions e technical modifications made to the appliance by persons other than the qualified technical staff 7 6 ELIMINATION OF DEFECTS REPAIR Independent of any statutory provisions acknowledged as taking precedence over the terms of this warranty a