Home
REG-PED
Contents
1. include control lines data lines and the requested power supply potentials With the help of parameter driven onboard functionalities you can adjust the inversion of the specific signals The status of each channel is shown on the 3 LEDs on the front panel for showing sending activity green receive activity yellow and error condition red Socket Connections on the front On the left hand side of front panel you see a 9pin Sub D socket This is used for 1 serial COM port in order to supply e g settings data Via this connection you can easily do the settings of REG PED online at any time General Functions Beside the functions running by different software applications there are main functions protecting against malfunctions of the device These functions are implemented by hardware and software rou tines Reset There are four possibilities to trigger a reset on a REG PED A proper restart of REG PED is garanteed in each case A Eberle GmbH amp Co KG REG PED by pressing RESET on the front panel Watchdog runs up reconnection and return of power supply Reset by montoring software module Watchdog Watchdog is a hardware supplement to monitor the smooth process of the software It consists of a timer that has to be triggered continuously by a background software program Lack of retriggering leads to a hardware reset The correct status of watchdog is displayed by a red LED on the front panel near
2. is divided in two main sections e common part where only baud rate and device name or address have to entered and e advanced part where specialist may adjust spe Cifics This implies timeouts etc and other protocol spe cifics as well as modification possibilities of the telecontrol profiles Example picture of mounting in 19 rack Technical Data REG PED Ethernet connection You can order the board with e 2 RJ45 or e 1 RJ45 and 1 ST or e 2ST connectors The REG PED is available with either RJ45 or fiber optic ST connectors The RJ45 connector provides Ethernet at 10 or 100 MBit autoswitching whereas the fiber connectors are only available at 100 MBit speed REG PED only 3 different baud rates in total available Mnemonic REG PE Duo Base MPC885 FEC Fast Ethernet Connector SMC SCC Serial COM Ports 1 without hw handshaking signals 2 normally used for connected eberle device Note All kinds of REG PE come without power supply whereas REG PED comes always with power supply N a a PMA6 S05 J Sorok maona PMA6 S05 Picture 2 Fibre optic ST version Picture 3 Electrical RJ453 version 5 A Eberle GmbH amp Co KG Technical Data REG PED C Mixed Ethernet operation If you order one Ethernet port with electrical RJ45 Example Applications A Com Server connector and the other Ethernet port with fibre a Com Server Only Application optic connector you are free in choosing conne
3. GB Technical Data Issue 2008 04 a eberle lt Central station coupling module REG PED as 19 rack version Application Working as a coupling device with control centres or with central units the REG PED operates with all telecontrol protocols Features e boots itself after power on e coordinates the telegram traffic between one or more substation units and WT and or modem connections to central stations or substations e checks automatically and continuously the me mory of the device controls the watchdog parameters can be set online at any time adjustable to any telecontrol protocol multiple choices for connection such as fibre optics RS 485 RS 232 Specification The REG PED board is equipped with an 32Bit PowerQuicc processor PPC885 and represents an independant computer with an address range of 1 GByte The CPU runs at a speed of 183 MHZ The board has a maximum capacity of 2 RAM modules with 128 MB in total memory as working memory E a eberie 2A D REG PED COMI SRIF COM SRIF COM3 SRIF COM 4 SRIF ETH 1 PIt0 100 Act ETH 2 PIt0 100 Act Depending on the kind of the module the storage capacity for saving of special system device data as well as for the specific remote control protocol structure are up to 64 MB flash memory All 16 hardware timers are required for the realtime operating system used One timer is used for the system cycle All of the prozess
4. c Up to 4 COM ports serve both Ethernet tor type Even contemporary use of both ports is connections assumed that the 2 Ethernet possible addresses are of different name spaces e g IP address of Port 1 is 192 168 1 214 and IP address of Port 2 is 10 0 0 215 b Mixed Application Any IEC protocol can be served at the same time working as com server to a device by priorizing IEC protocol before com server functionality B Dedicated Protocol Application a Working as Telecontrol Board for eberle devices Starting with IEC 60870 5 103 or 104 as tele control protocol for the substation connection of eberle devices you can easlily update later to IEC 61850 by firm ware update no hardware change needed b Working as Protcol Router e IEC 60870 5 101 to IEC 60870 5 104 Up to 4 COM ports may be used to con nect the Router to IEC 60870 5 101 lines of several substations to multiple control centres via IEC 60870 5 104 The needed settings for this application reduces to enter addresses and baudrate e IEC 60870 5 103 to IEC 60870 5 101 With the help of the fibre optic star coup lers of eberle you may connect up to 8 IEC 103 devices to one COM port of REG PED board and route information to another COM port with EC 101 protocol e IEC 61850 to IEC 60870 5 104 One Ethernet Port may be connected to IEC 61850 and the other Ethernet port to IEC 60870 5 101 or both protocols may be operated at the same Ethernet port A Eberle G
5. feature Z31 Z92 2 2 x FO glass with ST connection D5 cont with feature 731 Z92 S 1 x RJ 45 and 1 x FO glass with ST connection D6 cont with feature 731 Z92 combinations of D1 to D6 D9 7 A Eberle GmbH amp Co KG Technical Data REG PED CHARACTERISTIC FO version Fibre optic connection with FSMA glass wavelength 800 900 nm distance lt 2000 m plastic wavelength 620 680 nm distance lt 50 m two or three fibre optic connections on demand Fibre optic connection with ST glass wavelength 800 900 nm distance lt 2000 m plastic wavelength 620 680 nm distance lt 50 m two or three fibre optic connections on demand Protocol IEC 60870 5 103 IEC 60870 5 101 DNP 3 0 MODBUS RTU v 2 aa x al o o g o o IEC61850 IEC 60870 5 104 Please note In case of IEC 60870 5 104 please specify the target SCADA system Additionally please note that with Z92 COM Server function is not available 100 MBit s Operating manual German English ACCESSORIES KENNUNG Parametrization tool running on REG PED HW WebREG meant for remote control of REG D DA and PAN D Please note It is available in combination with IEC 61850 A Eberle GmbH amp Co KG presented by Aalener Str 30 32 D 90441 Nurnberg Phone 49 0 911 62 81 08 0 Fax 49 0 911 62 81 08 96 htto www a eberle de info a eberle de 7T227D201 01 INDD A Eberle GmbH amp Co KG 8
6. lass plug in device terminal block Mounting according connector block ALU RAL 7035 3U 6T 129 mm 71 mm lt 0 4 kg IP OO IP OO DIN 41494 Part 5 DIN 41612 REG PED 7 45 40 3 8TE Picture 1 Dimensions plug in module Data programming cable Cable has to be shielded and may not be longer than 1 5m PC Sub D meaning Connector REG PED Sub D Connecotr 9 pin n a TXD SMC1 RXD SMC1 n a GND n a n a n a O dWdINIOI aA HRI Wyrm n a A Eberle GmbH amp Co KG Technical Data Electric security Protection class l Grade of pollution 2 Overvoltage category rated isulation voltage Over max Overvoltage voltage 300 V front 350 V back Serial interfaces Serial interfaces i Transient voltage 5 KV 1 2 50 ms 0 5 Ws strength Immunity Airload 8 kV Contactload 4 kV Electrostatic discharge 80 MHz 1000 MHz 10 V m 900 MHz 5 MHz 10 V m pulsemodulated Electromagnetic fields Rapid transient disturbance quantities Bursts Power supply AC 230 V 2 kV Contacted RF 0 15 MHz 80 MHz disturbance factors U 10V 50 Hz magnetic field 30 A m Disturbance emission Group 1 limit class A Electrical Connection Terminal screws with selflocking protection clip on connector block RS485 Processing In order to terminate the RS485 bus you can activa
7. mbH amp Co KG 6 Technical Data REG PED Order details Only one code of the same capital letter is possible e When the capital letter is followed by number 9 further details are necessary e The code can be omitted when the capital letter is followed by zero e An X code e g XP1 cannot be combined freely with other codes CHARACTERISTIC Protocol Interface Unit 8TE 3HE REG PED for connection of the automatic voltage controller system REGSys to SCADA systens with Power PC MPC 885 16MB flash 32MB RAM with 2 COMs incl parametriezation tool WinConfig REG PED can also be used as a COM Server Please note REG PED could also be used as data conzentrator 103 gt 107 or as a Router 101 gt 104 or IEC61850 server gt 103 client Design 1plug in unit B1 installation with other REGSys components B9 Power Supply AC 85V 110V 264V DC 100V 220V 280V HO DC 18V 60V 72V H2 Type of application as Com Server only LO with 4 x RS 232 and 3 x RS485 and RJ 45 cont with feature group G for connection of one REG D L1 for connection of combinations of REG D DP EOR D PQI D L9 CPR D etc Note L9 can only be used in combination with Z02 Z31 Z92 Type of connection a RS 232 D1 2 cont with feature Z01 Z23 x RS 485 two wire operation only D2 o cont with feature Z01 Z23 o 1 x FO glass with ST connection for Z01 223 D3 S cont with feature group V 2x RJ 45 D4 D cont with
8. or included UART modules turn the 5 asynchronous V 24 interfaces 3 of these interfaces have their own baudrate ti mers The PARAM interface is able to work from 1200 up to 115200 baud and the other serial interfaces 1 4 from 300 Bd up to 115200 baud For serial coupling in pulse width modulation pulse duration m 100 Bd up to bis 2400 Bad are available All interfaces can be used either in PWM or in PCM pulse code m mode or as control lines for modem serving up to 4 coupling partners can be served Despite the functions running by different software branches on REG PED there are general functions in order to protect the REG PED module against malfunctions These functions are implemented by hardware supplements and by software parts A Eberle GmbH amp Co KG Technical Data Interfaces The REG PED module offers the following interfaces for communication with parametrizing PC and for connection with serial communication partners depending on mounting version e 2x10 100Mbit Ethernet RJ45 or fibre optic ST e 5 serial interfaces e 2 4 of those serial interface to PCM or PWM coupling partners e 2 3 of those serial interfaces RS485 e up to 4 serial fibre optic interfaces optional e 3 COM interfaces have transmitters and receivers with galvanically isolation by optocouplers e all COM ports are able to work in V 24 mode Interfaces for serial communication are connected via rackmount or SUB D connector They
9. te a termination resistor by soldering according short circuits depending on used mainboard type Fibre optic connectors for COM 1 4 All conncetors have SMA ST standard size The wavelength is at 660 850nm and is ready for glas and plastic fibre optics Jumpersettings fibre optic board Jumper meaning X5 1 receiver invert X6 1 transmitter invert A Eberle GmbH amp Co KG REG PED Operating modes The telecontrol board REG PED has got no jumpers on board In order to switch between the operating modes RS485 and RS232 fibre optic mode is done via RS232 mode and additional piggy back module a software parameter has to be set accordingly Commissioning of the board For commissioning purposes a quick guide and an elaborately user manual with parameterizing guide is coming with the board and also downloadable on our home page The parameterizing is done via web browser or a Windows based application Fields of application The telecontrol board REG PED processes the following telecontrol protocols together with eberle devices IEC 60870 5 101 IEC 60870 5 103 IEC 60870 5 104 IEC 61850 DNP 3 0 Routers IEC 60870 5 101 to IEC 60870 5 104 IEC 60870 5 103 to IEC 60870 5 101 IEC 61850 to IEC 60870 5 104 e Modbus RTU e Other protocols on demand The telecontrol connection can be made via RS232 RS485 and fibre optics Settings are done via web browser or a Windows based application which
10. the Reset button Contact positions for COMs and power A DIN C Connector COM1 RTS COM1 485 P COM2 RxD COM4 RTS COM4 485 P COM1 GND COM3 RTS COMS 485 P N Signal COM1 485 N COM1 GND COM1 RTS COM1 CTS Signal COM1 485 P COM1 RxD COM1 TxD COM1 485 N COM1 is paralelly available at a SUB D Connector N B COM1 may only be connected at one time via DIN F Connector or via SUB D Connector Technical Data Technical Data Processor Processor Technology Memory Operating system Serial Interfaces Input resistance Output resistance Input voltage Power supply TK885 MPC885 CMOS 16 128 MB SDRAM realtime UNIX 5 1000 Q 120 Q 3 12V 5 V 10 0 6 A max Reference conditions during operation in a 19 rack temperature relative humidity Storage temperature relative humidity Parametrizing TK885 10 55C max 85 at 25 C 25 65C max 80 at 25 C A generated file is transferred via serial RS232 or Ethernet interface from a standard PC into REG PED Data is kept in flash memory Settings can be done via web server of REG PED too Applied rules and standards EN 55011 1991 und EN 50082 2 1995 DIN 40050 EN 50178 VDE 0160 11 94 ICE 1010 EN61010 VDE 0411 ICE 255 4 ICE 529 VDE0110 IEC 664 1 VDE0106 Teil 100 CE Mechanical construction Front Panel height width weight Protection c
Download Pdf Manuals
Related Search
REG PED regedit.msc rag peddler lexington ky reg predial reg editor rag peddler rg pedrinho rag peddler fabrics lexington ky reg pet scan rg pedro aleixo reg permitting reg pet bottle reg pendiente de entrega en destino
Related Contents
COLLES SANS SOLVANT NI 9242 User Manual and Specifications Copyright © All rights reserved.